Home

TECDIS USER MANUAL

image

Contents

1. FRONT VIEW 457 20 18 00 7 8650 0 24 BOTTOM VIEW L TOP VIEW 422 12 16 62 S sl Le hid 5 zd N 5 50 0 22 THRU ALL 10 50 0 41 x 90 SIDE VIEW 78 44 j09 iain 478441309 g 1 1 M E J 8 BT 0 23 m PANEL CUTOUT 5 5 88 0 23 1 Metric thread M5 or 0550 10 22 co E i o o 10 50 0 41 Dimensions might be shown with or without decimals and indicated as mm inches Tolerance on drawings is For accurate measurements check relevant DWG file as obtainable from http www hatteland display com portfolio displays series2 php Page 26 TECDIS Installation Manual Outline dimensions for HD 19T21 MMD 4xR 3 50 0 4 10 53 041 150 00 59 15100 5 94 15 04 382 00 Y FRONT VIEW 429 00 16 89 5 TOP VIEW hi B 407 93 16 06 i BACK VIEW 4 x M6 Vesa mounting Max 12 mm deep B 28000 11 02 14 50 2 93 14 53 369 00 SIDE VIEW 74 50 2 93 r si 13 17 334 47 1 54 e 2 3 e e DIMETRIC VIEW 412 00 11622 4xR 4 00 0 16 PANEL CUTOUT TECDIS Installation Manual Page
2. d 000000000000000000000000000 000000000000000000000000000 2 POSTA 1 432 0 l m 743 22300 n i E 65500 Y gt 4 28 lezal 505 0 Page 30 TECDIS Installation Manual Outline dimensions for Furuno MU 231CE 540 0 598 0 570 0 743 0 FURS 6 EI e e n pie e i v 4 28mm TECDIS Installation Manual Page 31 1 1 5 Outline dimensions for ISIC monitors Outline dimensions for ISIC DuraMon 19LED oec 27 5 428 1 4 419 5 26 86 5 4 7 RE 8 BOSS 465 483 0 5 432 Recommended panel cut out Page 32 TECDIS Installation Manual Outline dimensions for ISIC MD 26KM05 DuraMon 26 WS 4 422 20 5
3. r z s 00 9 o LU gt 2 Ll S o 5 HI HF x le o il Ho 666 00066 2661 8 LM Hs 79211600 781 59006 70 5092 9201 100 gt 0H Lu oO gt 0991 2579 O lt m we i 461 5006 Die 2 00 0 0 TECDIS Installation Manual Page 35 Mounting bracket for HT 01 TEL A596 D596 included All figures in mm inches FRONT VIEW EXPLODED VIEW 22 50 0 89 BOTTOM VIEW a e E 3 4 x 8 countersunk screws Other screws may damage the computer 5 D 2 0 9 600 26 THRU ALL o 12 60 0 50 90 E R3 25 0 13 a R7 00 0 28 o o a A c f 1 NEN o o 250 00 9 84 BE gt gt 364 00 431 335 390 00 15 35 eig o t y 4 2 e 364 00 14 33 of 69 75 275 Other drawings including 19 rack kit 4U HT 00223 1 are available from the following URL http www hatteland display com computer_htc01 php Drawing of optional 19 rack mounting kit Enix 2000 series
4. 12 Generales eese te s 2 TECDIS Track control system with 5500 13 MOUSE TRAK B MPIND XROBHS eee ee eee eene eto sero sone eo neenon seen sees essen se enseensesoeesoe 18 CHAPTER 1 DU 1 1 Monitor UI 1 1 2 OUTLINE DIMENSIONS FOR HATTELAND DISPLAY PROCESSORS WITH INTEGRATED MONITOR 21 1 1 3 OUTLINE DIMENSIONS FOR HATTELAND DISPLAY MONITORS ci 22 1 1 4 OUTLINE DIMENSIONS FOR FURUNO MONITORS 0 cce iii 29 1 1 5 OUTLINE DIMENSIONS FOR ISIC MONITORS 31 1 2 Processor LE 1 2 1 SPECIAL CONSIDERATIONS FOR HT CO1TEL A596 D596 eene 33 1 2 2 SPECIAL CONSIDERATIONS FOR ENIX 2067 TEL D1 enne tn nena 33 1 2 3 OUTLINE DIMENSIONS FOR HT C01 TEL A596 D596 34 1 2 OUTLINE DIMENSIONS FOR ENIX 2067 TEL Dl 36 1 3 Control Unit Furuno 018 22220205 5 5 4 aee Pe kae zine J7 1 4 Keyboard
5. JI 1 4 1 OUTLINE DIMENSIONS FOR KEYBOARD CHERRY G84 4100 i 40 1 4 2 OUTLINE DIMENSIONS AND CUTOUT FOR KEYTOUCH PANEL QWERTY i 41 1 4 3 OUTLINE DIMENSIONS AND CUTOUT FOR KEYTOUCH PANEL TRACKBALL ii 42 1 4 4 OUTLINE DIMENSIONS FOR KEYTOUCH PANEL COMBO 00000 01 0000000000000000000000000 43 1 4 5 OUTLINE DIMENSIONS FOR TECDIS KEYPAD 44 1 5 Additional isa 1 5 1 OUTLINE DIMENSIONS FOR ALARM INTERFACE TEA O1 ccccccccccccssssssscecececsessaececccecsenenecececeeeesenseaeeeeeceeees 45 1 1 1 OUTLINE DIMENSIONS FOR LOUDSPEAKER DNH HP6 WITH BRACKET MOUNT 46 1 1 2 OUTLINE DIMENSIONS FOR LOUDSPEAKER DNH HPS6 FOR FLUSH MOUNT iii 46 1 6 Track Control Ansch tz NP 2025 PLUS 47 1 7 Track Control Furuno 2000 and EMRI SEM 200 Autopilot 48 1 8 Track Control Raytheon Ansch tz 5500 49 19 NAUT AW Gyro Sensor Input Requirements 00 1 CHAPTER 2 WIRING AND SIGNAL DISTRIBUTION 4 92 2 1 Serial connections for HT C01 596 13596
6. Recommended panel cut out 250 TECDIS Installation Manual Page 33 1 2 Processor Unit The processor unit can be mounted inside on bridge console or other suitable space on the bridge When selecting a mounting location keep in mind the following points 1 Select a location where vibrations are down to a minimum try to avoid vibrations by adding strength to console where the processor is about to be installed 2 Locate the unit away from heat sources because of heat that can build up inside the cabinet 3 Locate the equipment away from places subject to water splash and rain 4 Leave sufficient space on the sides and rear of the unit to facilitate maintenance and interconnection cabling 5 A magnetic compass will be affected if the processor unit is placed too close to the magnetic compass Observe the compass safe distances to prevent deviation of a magnetic compass The distances are listed on page 3 6 Navigator shall update charts in the processor weekly Mount the processor at a location that enables the navigator easy access to front doors of the processor It must be possible to open CD DVD drawer of processor without obstructions or access an available USB 2 0 port More on updating charts in chapter 3 5 1 7 The power switch shall be easily to access front of processor may be flush mounted in the console to enable access or other means to be provided for easy access 8 Service k
7. 52 2 2 Serial connections for HD 24721 MEC ssccccsssssssssssssscsscsecccsscssssssceccsecssssssssssscesess DI 2 3 Serial connections for ENIX 2077 TEL D ccccccsssssssscssscsssssssssscscccccssssssssssscesess DI 2 3 1 RECONFIGURATION OF COM PORTS ON ENIX 2077 TEL D1 iii 54 24 Wiring 2 4 1 HT GOI EBELE A5964 D596 iade Edo RB RERO ees 55 2 4 2 HD24TI2LMBG na el e e Mee ao 56 2 4 3 ENIX 2077 TELZDIT nico i Leal Lala ai a 57 2 5 Signal distribution diagram internal data 22 40 4 2 6 Processor CODeC OLS 4er iodees eres erre dedo eo ee on a copa uda eu euo caca ea I 2 6 1 596 40596 5 i ette eoe alia e eee e DE e eae 59 Page 6 TECDIS Installation Manual 2 6 2 2 6 3 2 7 2 8 24 21 alice e RE E iaia EE QUU Oi Es ia 60 ENIX 2077 TEC D erit be e e Ete dette see eerte O E o DR lei usi 61 Other notes regarding connectors and 1 esee ee ee ee eere 62 Other connectors CHAPTER 3 PARAMETER SETUP 04 3 1 3 2 3 2 1 3 2 2 3 2 3 3 2 4 3 2 5 3 2 6 3 2 7 3 2 8 3 2 9 3 2 10 3 2 11 3 3 3 4 3 5 3 5 1 3 5 2 3 5 3 3 5 4 3 5 5 3 5 6 3 6
8. 9 50 0 37 9 50 0 37 434 00 17 09 19 42 0 76 19 2 0 76 130 54 5 14 1 130 54 5 14 75 68 2 98 1 1 75 68 2 98 dei SIN Dimensions might be shown with or without decimals and indicated as mm inches Tolerance on drawings is 1mm For accurate measurements check relevant DWG file as obtainable from http www hatteland display com maritime line displays series 1 php TECDIS Installation Manual Page 23 Outline dimensions for JH 19T14 MMD FRONT VIEW SIDE VIEW BACK VIEW 483 00 19 02 465 00 18 31 444 00 17 48 267 00 10 51 Area for custom logo 8 2 8 438 00 17 24 BOTTOM VIEW 129 00 5 08 129 00 5 08 i 8 13 50 053 L 1350 0 53 4 r N 25 m E a Optional holes 26 5 0 26 PS TOP VIEW screwed from the wis of panel 9 434 00 17 09 ei 4 places horizontally i E PANEL CUTOUT 5 2 sa Metri M 2 g eem 5 u 5 i 13 50 053 1350 0 53 al 129 00 jm 508 Dimensions might be shown with or without decimals and indicated as mm inches Tolerance on drawings is For accurate measurements check relevant DWG file as obtainable from
9. ccsscccssssccsssscssssscssscsssscssssscssseesees 94 CHAPTER 6 CHECKLISTS REGARDING INSTALLATION 44 44 9 6 1 Checklist prior to completion of TECDIS installation 000 2 2 96 62 Checklist prior to completion of TECDIS TCS and TECDIS AW installation 98 6 3 Additional checklist prior to completion of TECDIS AW installation 105 6 4 Installation Note s 2 ero on ee eren e e se pono eh ee ea ro so oe paren eae cc ope aa eee e sus uae oe Iona o eae ao eae se 106 Page 8 TECDIS Installation Manual TECDIS Installation Manual Page 9 General introduction to the installation manual This manual is describing the procedure to ensure a proper and safe installation of our TECDIS onboard a vessel Please read carefully this manual before you start up the commissioning of the TECDIS The installation and commissioning of the TECDIS must be performed by an authorized service engineer which has undertaken training or in other forms gained the required skills to perform an authorized installation of a TECDIS system onboard a vessel To ensure a professional after sale service and a personal track record of TECDIS installations we recommend that the service engineer saves the default setup file to a usb memory dongle or other media He can then keep this file in his personal register of TECDIS installations The file is locat
10. TRO on Tag Ro 4 CD via A his 4 sod II v i 4 1 90 fully type approved Electronic Chart and Display Information System ECDIS certified by DNV n IUS TECDIS Installation Manual Page 3 A SAFETY INSTRUCTIONS A WARNING Do not open the equipment unless totally familiar with electrical circuits and service manual ELECTRICAL Only qualified personnel SHOCK should work inside the HAZARD equipment Turn off the power at the mains switch board before beginning the installation Fire electrical shock or serious injury can result if the power is left on or is applied while the equipment is being installed Do not install the monitor unit processor unit or control unit where they may get wet from rain or water splash Water in the units can result in fire electrical shock or damage the equipment Be sure that the power supply is compatible with the voltage rating of the equipment Connection of an incorrect power supply can cause fire or damage the equipment Use only the specified power cable Fire or damage to the equipment can result if a different cable is used A WARNING The PC Main board is equipped with a litium battery The lithium battery should be replaced only in the factory There is a danger of explosion if the wrong type of battery is used for replacement A CAUTION Attach securely protection earth to the
11. Manual Calibration Load Calibration File Allows the operator to manually load a monitor calibration file Monitor Connection Tests Provides access to tests to verify correct monitor serial connection buzzer test backlighting adjustment tests and monitor identification test TECDIS Installation Manual Page 77 3 6 Licensing TECDIS TELchart ECS Setup local Ip 192 168 0 150 8 X Nmea Data Specification Chart Installation Misc Licensing Track Ccontrol r TELehart License Show edit license C Map License System ID Databases Telko eT 00006 ENC Add License manually Data Set or Area Name um Hydrographic Office UK Get expired licenses Hydrographic Office South Africa Licenses ist Instituto Hidrografico de la Marina Spain Add Licenses from file Hydrographic Office UK E License order License string Add License 3 6 1 TECDIS license By clicking Show edit license information about the current system license is shown as illustrated below This information includes the license number and version information and a list of installed optional components in blue in the right part of the area In order to activate additional optional components a password for this should be entered in the Password field and the Program button should be clicked Standard version Chart server engine Name seek Seismic streamers Co
12. Horizontal sync or composite sync input Vertical sync input DDC serial clock Pin Assignments 5P PS 2 KEYBOARD Pin 6 Not Connected Pin 5 Keyboard Clock Pin 4 Vcc 5V HU Pin 3 Ground Pin 2 Not Connected Pin 1 Keyboard Data Page 64 TECDIS Installation Manual Chapter 3 Parameter Setup When you first start the TECDIS computer it will automatically start up and enter the TECDIS program Windows XP TECDIS and TECDIS Setup software are pre installed To exit TECDIS program for commissioning and installation procedures using TECDIS Setup software see chapter 3 1 Service Mode for details 3 1 Service mode Windows When you exit TECDIS using the STOP button at the upper left corner the chart plotter will automatically be turned off after you confirm that you want to exit In order to exit TECDIS without turning the chart plotter off you must insert the USB Service Key memory dongle before you exit TECDIS When this service key is connected to the chart plotter the chart plotter will not be turned off when you exit TECDIS and you will be able to work in Windows service mode and open the Setup program by double clicking on the Setup icon on the desktop When service mode is available a text indication is shown in the lower right corner of the chart 3 2 NMEA data setup The NMEA Data folder in the TECDIS Setup constitutes all controls and settings for inputs and outputs to and
13. Location of change over controls The steering mode selector switch or override facility if installed shall be located at or in the immediate vicinity of the main conning position Connection to TECDIS The Furuno FAP 2000 Autopilot s or EMRI SEM 200 Autopilot s Electronic Unit AEU 511 ETS1 Connector Module must be connected to a TECDIS serial port and configured in TECDIS SETUP See chapter 3 7 TECDIS Installation Manual Page 49 1 8 Track Control Raytheon Anschiitz NP5500 We refer to NP5500 Autopilot Operator Unit Service Manual and Interface Unit Service Manual for installation of the autopilot All applicable procedures and guidelines are to be followed For information on which autopilot settings that are needed for Track Control see section Autopilot installation settings on the next page For valid installation and operation of Track Control functionality TECDIS must be as a minimum be connected to the following Two Independent position sensors Two Independent heading sensors Speed sensor Alarm System for transfer of back up navigator alarm TECDIS and the NP5500 Autopilot must be supplied with the same set of heading and log sensor inputs e Alarm System for transfer of back up navigator alarm Both TECDIS and the NP5500 must be configured with the same LOW SPEED LIMIT value The NP5500 has to be configured with SASS Syberg Autopilot Safety system to ensure rudder freeze functionality Se
14. Position fixing Displays 2 sources for TIM Radar 2 ino data positioning Primary and secondary can be PT RSD Radari OK selected Primary and secondary can be pr COMI RSD Radar 2 dog displayed simultaneously on the chart Ais OK display If primary position fixing system Dybde OK falls i automatically uses 5 MWY OK secondary If both positioning systems D drop change over to dead reckoning is Route comm m executed Log Gyro Use Position 1 as primary position ok Display both primary and secondary position 4 2 Operational parameters for the Ship 4 2 1 Own ship offcenter Location of own ship the screen High value Vessel is placed more offcenter Low value vessel is placed closer to screen centre This function is only active when auto function is enabled Log Safe Ais Own ship offcenter rer Tee RT Ga 4 2 2 Auto sensitivity Auto sensitivity How often chart to be centered shifted in Auto mode 4 2 3 Show double circle Show double circle The boat symbol can be displayed with or without circles Show ship outline 4 2 4 Show ship outline Course vectors This option allows the true vessel outline to be displayed in the chart Length 5 min 4 2 5 Course vectors Sets vector length on own ship and targets One cross line on vector is one minute 4 2 6 Wheelover E Wheel over line d
15. Cancel TECDIS Installation Manual Page 55 2 4 Wiring diagram e For HT COI processors continue to chapter 2 4 1 for wiring diagram e For HD 24T21 MEC processor continue to chapter 2 4 2 on page 56 e For ENIX 2077 TEL processor continue to chapter 2 4 3 on page 57 2 4 1 C01 TEL A596 D596 230VAC a mE Some models with DC Powe Supplied Cable N 230VAC Supplied Cable 596 230 VAC OR Some models with DC Pi 0596 24 VDC in Operator accessible power toggle x2 for Keytouc Panel Combo ALARM CENTRAL ALARM OUT ALARM OUT SOUND ALARM OUT RESET ND ALARM OUT RESET ND ALARM INP RESET DUND ALARM INP RESET E SHIELD SM 92 uoweing 216110 03761 uoWeing 2151 FOLEZ NIN ouninj FOLOZ NIN 12192 21 2 VCL6LOH YOLINOW 510931 AWN vL1 2 21102 YLL6LHF 016LQH PUEIONEH ALARM INTERFACE Telko TEA 01 230VAC Suee Some models with MANDATORY Position Heading COG SOG TRACK CONTROL MANDATORY Raytheon Anschitz NP2025 PLUS HOSS3OO0Hd OPTIONAL Alarm Central Water Speed ARPA Radar Cursor Depth Rel Wind Route AIS APB Out RMB Out RMC Out RTE Out 9650 968 v 131 100 LH pueieneH YOLINOW Moxa CP118U I QHVOSA3 00Lt 789 LAN SWITCH s
16. TECD 351 00 S rs 5 a ae gt lt gt x lt SS an 2 4 S gt sS D gt gt S 4 SS a lt gt S x LZ 4 9 lt gt LL ASS 7 DD AR SD 0 SS lt lt TECDIS Installation Manual Page 37 1 3 Control Unit Furuno RCU 018 The control unit may be mounted on a desktop with or without the KB fixing metal supplied which mounts the control unit at an angle Mounting considerations When selecting a mounting location keep in mind the following points e Select a location where the control unit can be operated conveniently Locate the unit away from heat sources because of heat that can build up inside the cabinet Locate the equipment away from places subject to water splash and rain Determine the mounting location considering the length of the signal cable between the control unit and the processor unit A magnetic compass will be affected if the control unit is placed too close to the magnetic compass Observe the compass safe distances specified at the start of this manual to prevent deviation of a magnetic compass Fixing with KB fixing plate 1 Fix the KB fixing plate to the bottom of the control unit 2 Attach three cushions to the bottom of the control unit 3 Fix it to a desired location with self tapping screws local supply Fixing without KB fixing metal 1 Drill four mounting holes of 5 mm diameter referring to the outline dr
17. 3 6 1 3 6 2 3 6 3 3 6 4 3 7 3 7 1 3 7 2 3 7 3 3 7 4 3 7 5 3 8 3 8 1 3 8 2 3 9 Service mode Windows 1 1 OF NMEA data S Ml IR LU EIHESEOTBDUL MP 64 INFO TEXT 65 NMEA SENTENCE x pte toten E a o ira 65 THE BAUD EPA FIEED eere re ERI 67 SERIAL PORT ACTIVITY ER RE HS PEERS Ue n eS TREE ETE ENSE PP TRA 67 RECEIVED DATA ON 2 67 OTHER COM PORT CONNECTIONS sscssccssccscessessccuccsecessenseeuecscesceensnneaescesceesenacesseesceesenneesscesceseenseeuecesceseenee 67 THE QUTPUT FOLDBR t Eee deca Ee urere Eee 68 SUPPORTED NMEA SENTENCES enaa E AE EEE ES e 69 SRG EE E EE E E TECDIS NMEA and TCP IP Server cccccccccscssscssscssscscssscssscscscssscscscssscscscscssccscscsesece 72 Chart Installation Mlisc 5 ee ee eren INSTALL UPDATE OR REMOVE CHART DATABASES esee ener nenne tern nnns sees entere nnns sesenta tens senseri 73 TRANSFERRING CHARTS FROM
18. Power Consumption Idle 8mA Max 12mA Mechanical Specifications Dimensions Approximately 4 wide x 8 long Weight 1 3 Ibs Body Material Glass filled Xenoy thermoplastic black Ball Material Cast Phenolic Resin Ball Hardness Rockwell H 85 Tracking Force 1 5 oz maximum 0 5 oz typical 15g Ball Load 250 lbs maximum downward Ball Speed 500 RPM maximum Hand Pad Injection molded vinyl black Environmental Specifications Operating Temperature 0 to 50 degrees Celsius Storage Temperature 20 to 60 degrees Celsius Humidity 0 to 95 non condensing Cherry G84 4100LCMGB 2 keyboard 11 black ultra slim QWERTY keyboard Space reduced 86 key layout Mechanical keyswitches with lasered keycaps Key switch lifetime 20 million operations Connection USB or PS 2 Adaptor Dim 282 W x 132 H mm TECDIS Installation Manual Page 19 Speaker HP 6 HPS 6 Material Color Mounting Termination Weight IP rating UL Equivalent Max min amb Temp Rated max power SPL 1W 1m SPL rated power Effective freq range Dispersion 6dB 1kHz 4kHz Directivity factor Q Telchart Alarm interface TEA 01 Outputs connector 1 2 3 4 Polyamide UL94 RAL 7035 Bracket Cable 0 5m 0 5 kg 67 90 C 40 C 6W 15W 101 db 108 db 500 7500 Hz 170 70 4 3 are a solid state relay LCA110E which has capabilities of max 50VDC max 200mA Input connector 5 6 uses
19. Response time 20 ms Contrast ratio 1000 1 Light intensity 300 cd m2 Viewable angle 89 deg H V L R Display area 376 32x301 056 mm H V Auto detects VGA to SXGA Optimum picture with 60 Hz Input signal 2x DVI D 24pin Input signal 2x RGB 15pin HD D sub Input signal 3x Comp video BNC connector Control input output RS 232 D sub Opin Multi power supply 115 amp 230 VAC 50 60 Hz 24 VDC 42 W typical Weight 8 2 kg HW revision number is part of model number Page 16 TECDIS Installation Manual Monitor HD 24T21 MMD 24 0 inch widescreen viewable image size Active matrix MVA Thin film Transistor LED backlight Pixel number 1920 x 1080 Full HD Pixel pitch RGB 0 276 mm H V Response time 25 ms Contrast ratio 3000 1 Light intensity 300 cd m2 Viewable angle 89 deg H V L R Display area 531 36x298 89 mm H V Auto detects VGA to WUXGA Optimum picture with 60 Hz Input signal 2x DVI D 24pin Input signal 2x RGB 15pin HD D sub Input signal 3x Comp video BNC connector Control output input RS 232 D sub 9pin Multi power supply 115 amp 230 VAC 50 60 Hz 24 VDC 49 W typical Weight 11 0 kg HW revision number is part of model number Monitor Furuno MU 201CE 20 0 inch viewable image size Active matrix Thin Film Transistor Pixel number 1280 x 1024 Pixel pitch RGB 0 301 mm H V Contrast ratio 600 1 Light intensity 250 cd m2 Viewable angle 85 deg H V L R D
20. color coding e Section 3 5 1 Install update or remove chart databases on page 49 50 updated with information about new function Remove Licenses TECDIS Installation Manual Page 109 Revision 1 8 15 11 2007 e General introduction to the installation manual updated with new configuration data file e Section 1 6 updated with minimum sensor and other connection requirements for Track Control functionality and requirements to ensure freeze rudder functionality e Section 6 Added checklists for Track Control system and installation notes Revision 1 9 16 04 2008 e Changed heading for section 6 2 to include TECDIS AW e Added new section 6 3 for additional TECDIS AW requirements checklist e Old section 6 3 and 6 4 now section 6 4 and 6 5 e New section 1 7 for NAUT AW gyro sensor input requirements Revision 2 0 20 01 2009 e Updated to reflect changes in new software version 4 7 1 e Deprecated hardware options removed from equipment list mounting and wiring chapters Revision 2 1 17 11 2009 e General introduction to the installation manual updated to include internet switch and installation checklist requirements e Section 2 3 Processor connectors HT 405P4 TEL A1 updated to include requirements for internet switch e Chapter 6 Checklists regarding installation updated Revision 2 2 07 06 2010 e General introduction to the installation manual updated to reflect that connection to UPS is no lo
21. info GGA Com4 4800 GPS1 GGA Com5 4800 GPS2 Com4 4800 GPS1 VTG 5 4800 GPS2 Sentence and port select a coh gt fonder SS VBW Coms 4800 Log per TCP bon 0 0 0 0 10028 Radar 1 P3 C UDP 17281871 TIM 0 0 0 0 10028 Radar 2 Radarcursor1 RSD 0 0 0 0 10028 Radar 1 Serial port activity Radarcursor2 RSD 1 1 0 0 0 0 10028 Radar 2 E E BBs tna i Alxxx 9 38400 AIS E ES Received data on selected port Clear MWV 11 4800 Wind GPGNS 074403 5904 875 N 01029 000 E A 4 0F WPL GPGGA 074403 5904 875 N 01029 000 E 1 4 64 ra eame peces Main display GPGLL 5904 875 N 01029 000 E 074403 A A 4B GPVTG 0 0 T 10 0 N 4 5 K A 70 Digi 1 4800 Alarm central GPRMC 074403 A 5904 875 N 01029 000 E 10 0 0 0 150512 A 63 Rcu18 Com2 19200 Furuno keyboard GPZDA 074403 00 15 05 2012 02 00 4D VDVHW 0 5 T 12 3 M 10 5 N 23 SHEHDT 1 0 T 2E NRX Sera SRAOSD 0 5 A 0 0 W 10 0 W N 72 Flir VDVBW 10 5 0 0 A 10 0 0 0 A V V 54 SDDPT 20 0 2 2 49 SDDBS 65 6 f 20 0 M 10 9 F 3E SWIMWYV 0 0 R 5 0 M A 25 WIVWR 0 0 R 5 0 M 57 SRDTTM 1 0 5 0 0 T 10 0 0 0 T 1 2 3 4 N INA T 2A Ansch IP ports TECDIS has 12 COM ports and 4 IP ports For each IP port the IP address and port number must be entered The Test button establishes
22. test F do so now then run the following file and see if the problem is fixed C Program Files TECDIS AddCMapHosts exe If test J failed have your network administrators check the firewall Make sure that the firewall in your internet setup is not blocking your weather data requests E MAIL CONNECTION L M Check your spam folder Make sure that the replies to your request email from Jeppesen Marine are not being marked as spam Try setting a lower Max Attachment Size Your email service may be having problems with the weather data attachments Try lowering the Max Attachment Size value in the Configure Connection window Make sure you are not using old request reply files Delete all request and reply files from the USB memory stick so that you are sure you are not using the request or reply files from a previous download or from the other TECDIS Update only one TECDIS at a time If you send weather update requests from both TECDIS systems at the same time it is very easy to get the reply files mixed up Page 96 TECDIS Installation Manual Chapter 6 Checklists regarding installation 6 1 Checklist prior to completion of TECDIS installation Task to be performed Verify that all selected ports are receiving transmitting data and that ports have been given names on both main and back up TECDIS Names shall be according to the data they are receiving transmitting and back
23. 2 connected to DUAL SYSTEM W MANDATORY 32 OTHER Zr TECDIS I OPTIONAL d Furuno I 9 i FAR 2xx7 O Radar 7 N o z Di 2 itm Furuno gio I 2 IF 8530 gt Remote 2i Junction box gt I i Page 56 TECDIS Installation Manual 2 42 HD 24T21 Supplied Cable 230VAC Some models with DC Power 110 230 VAC Operator accessible OR 24 VDC power toggle ptiona 1 Shielded CATS Cable Optional VSAT Internet 2 for Keytouch Service Key Panel Combo External CD DVD drive Keytouch panel QWERTY Trackball Combo CENTRAL ALARM OUT 15 ALARM OUT 25 SOUND ALARM OUT RESET 3 gt JUND ALARM OUT RESET 4 SOUND ALARM INP RESET GND 5 gt OUND ALARM INP RESET 6 gt gt CABLE SHIELD 7 min 3 2 022 shielded gt 150 4 gt 5 Oss ALARM INTERFACE 5 AZ Telko TEA 01 8 e gt gt gt gt gt gt gt gt gt T gt 1 D gt 1 gt 2 T 4 28 Tom 250 MANDATORY NI Position Heading COG SOG O TRACK CONTROL MANDATORY Raytheon Ansch tz NP2025 PLUS OPTIONAL COM 3 6 default as RS 422 Water Speed T 3 no 33 2 3 tached 1 2m 5 2 Cable Radar Cursor fin x02 Sie ee So DATA 9 Depth C zu
24. 27 Outline dimensions for HD 24T21 MMD 4xR 3 50 0 14 FRONT VIEW SIDE VIEW 59300 23 35 70 00 2 76 a m 5 s BOTTOM VIEW 33 85 DIMETRIC VIEW R TOP VIEW m 57690 2271 r 490 00 19 29 Il 4 x M6 threads for Vesa mounting Max screw length is 12 mm bl vg BACK VIEW r 280 00 11 02 15650 6 16 370 50 14 59 IF 7 3 27400 10 79 i s 4xR 4 00 0 16 z PANEL CUTOUT MO 1433 1 5 1350 0 53 J 0 1000 T 1 23 3 5 gt 8 561 00 2287 J eo 5 5 Page 28 TECDIS Installation Manual Outline dimensions for HD 26T21 MMD FRONT VIEW SIDE VIEW 4xR 3 50 9820 386 3 J BOTTOM VIEW DIMETRIC VIEW 3 TOP VIEW 871 0 34 60357 2376 9 ir 4 x 6 Vesa mounting BACK VIEW m 60900 2398 max 12 mm deep 317 02 1248 15199 598 gt 1 4xR 4 00 0 16 S 2 S E PANEL CUTOUT 3 8 i I 17050 6 71 8 117 50 Page 29 TECDIS Installation Manual 1 1 4 Outline dimensions for Furuno monitors Outline dimensions for Furuno MU 201CE
25. 3m Rel Wind DU di Route Ca oU AIS 8 SIE RD RA RMB Out aio RMC Out 4 S RTE Out Attached USB Cable aa LAN SWITCH zm 2 connected to 3 o dA DUAL SYSTEM g w MANDATORY 92 E OTHER Sur TECDIS 5 OPTIONAL Furuno FAR 2xx7 Radar min 2 x 0 22mm 00m Furuno 1F 8530 Remote Junction box S SdH HNO 9 dH VIMVads TECDIS Installation Manual Page 57 2 4 3 ENIX 2077 TEL D1 d Cable 230VAC Some models with DC Power Operator accessible power toggle suce UON 3OVAC Supplied Cable 24 VDC Some models with DC Power Optional VSAT Internet Shielded CATS Cable CATS Cable with RJ45 Connec with RJ45 Connectors 30m max 30m zo Data2 Data2 2 Data 2 4 shid Data 2 4 shld x2 for Keytouc Panel Combo TECDIS Keypad Keytouch panel QWERTY Trackball Combo Clock Analog RED 2 Analog GREEN Analog BLUE 6140 03761 uojyeng 2161 FOLEZ NIN ouning Analog BLUE 4 m Q o Analog HSYNC Analog HSYNC Analog GND lt Analog GND S 5 S 2 N o bal x Egg eo a E cogs E x CENTRAL 1 gt ALARM OUT ALARM OUT SOUND ALARM OUT RESET JUND ALARM OUT RESET JUND ALARM INP RESET gt iSOUND ALARM INP RESET gt CABLE SHIELD T 58 o9 NS amp 9
26. 5 N 1D x UDP Clients vDVBW 05 0 0A0 00 0A v 54 Options r 2001 0 Save configuration r 2002 0 2008 0 2004 0 Select input nmea port Set speed Assign Tep Ip port if unused Select nmea sentences to distribute lean Optional UDP broadcast Caddr 0 0 0 0 TECDIS NMEA and TCP IP server allows distribution of selected comport data out through a TCP IP network This way one sensor can be shared by multiple users in a TCP IP network NmeaServer is the provided software for administration these settings A shortcut should be present on Windows desktop As shown above HDT sentence is received on comport 3 and is retransmitted on port 2001 through TCP IP address 172 31 3 61 This means that backup ECDIS or other connected computers to the LAN network can receive HDT data through TCP IP by selecting correct IP address 172 31 3 61 port 2001 Setup procedure 1 Select appropriate comport with desired data 2 Select appropriate baud rate on receiving comport by using Speed dialog box 3 Select to which TCP IP port it shall retransmit data from the selected comport for example 2001 4 Describe with text connected device to TCP IP port backup station conning PC etc 5 Select which NMEA sentences you which to send you may select one multiple or all on one TDP IP port UDP Switches to UDP broadcast Only one client per computer is possible Data activity Shows activ
27. AC power 115 VAC 60 Hz 230 VAC 50 Hz 100 W max Weight 11 5 kg e HWrevision number is part of model number Monitor HD 19T03 19 0 inch viewable image size Active matrix Thin Film Transistor Pixel number 1280 x 1024 Pixel pitch RGB 0 294 mm H V Response time 12 ms Contrast ratio 600 1 Light intensity 450 cd m2 Viewable angle 89 deg H V L R Display area 376 32x301 056 mm H V Auto detects VGA to XGA Optimum picture with 60 Hz Input signal DVI I 24pin Input signal RGB 15pin HD D sub Input signal Multifunction AC power 115 VAC 60 Hz 230 VAC 50 Hz 66 W max Weight 9 kg approx e HW revision number is part of model number Monitor JH 23T14 MMD 23 1 inch viewable image size Thin Film Transistor Active matrix Pixel number 1600x1200 Pixel pitch RGB 0 294 mm H V Response time 12 ms Contrast ratio 600 1 Light intensity 400 cd m2 Viewable angle 85 deg H V L R Active display area 470 4x352 8 mm H V Auto detects VGA to UXGA Optimum picture with 60 Hz Input signal DVI I DVI I input 29pin Input signal RGB 15pin mini D sub Input signal Multifunction AC power 115 VAC 60 Hz 230 VAC 50 Hz 24 VDC 95 W typical 125 W max Weight 20 kg HW revision number is part of model number Monitor HD 19T21 MMD 19 0 inch viewable image size Active matrix MVA Multi domain Vertical Alignment LCD technology Pixel number 1280 x 1024 Pixel pitch RGB 0 294 mm H V
28. F is to be used when connecting the TECDIS unit to other TECDIS units Furuno VDR Adapter or Furuno FAR 2xx7 series radar e LAN connector LAN can optionally be used for connecting the TECDIS unit to other networks or internet To fully comply with type approvals when connected to internet a switch must be made available to disconnect TECDIS from internet when the connection is not in use HT C01 TEL D596 Wiring for DC power connector Screw terminal Page 60 TECDIS Installation Manual 2 6 2 HD 24T21 2 x Removable Storage Trays mmmtmt mmn T3 goose 5552222525222200005592209552200006999900565 8 n fees fazio r EH vaa pr 93 RI L 4 Eri 99 8 88 89 89 89 2 x RJ45 Network Mic In amp Line Out Grounding Screw RGB VGA Out RS 232 amp RS 422 RS 485 USB 1 2 3 4 Expansion Area for Optional Modules Power Serial ports COM 3 7 e Configuration of serial ports in the Expansion Area for Optional Modules can be found on page 53 e COM I is to be used for TEA 01 Alarm central interface e The USB 1 1 port is sealed and unavailable e Connect a USB extension cable included to a USB 2 0 port for easy access when connecting an external DVD drive or Service key e LANconnector LAN 1 Furuno is to be used when connecting the TECDIS unit to other TECDIS units Furuno VDR Adapter or Furuno
29. Shipment address Sjomannsveien 19 N 6008 Aalesund Postal address Servicebox 11 N 6025 Aalesund Telephone 47 70 10 29 50 Telefax 47 70 10 29 51 E mail furuno furuno no Web www furuno no M V BOURBON TOPAZ Branch office Deep Sea Furuno Norge AS Visitor address Shipment address vre Fyllingsvei 81 N 5162 Laksevag Postal address vre Fyllingsvei 81 N 5162 Laksevag Telephone 47 55 94 41 41 Telefax 47 55 94 41 51 Service telephone 47 992 16 950 Our service telephone is served when offices are closed
30. enabled on the main area of this part of the Setup program If Send on Diskette is selected the registration file will be saved to an inserted diskette If Send Manually is selected the registration file will be saved on the hard drive and a message informing you about the file name and location of the file Send this file to the specified email address whenever the Vessel information data is changed Alternatives Send on Diskette Save registration information on a diskette Send manually Save registration information to a file on the root of the G drive TECDIS Installation Manual Page 75 3 5 5 Start C Map Chart Manager The Start C Map Chart Manager button provides access to the C Map chart database licensing and diagnostics interface C MAP Chart Manager X Databases Licenses Updates Dynamic Licensing Network Config System Info About cmap Common actions Search automatically Register manually Default Selected database Unregister database Gheck signature Check integrity Set as Default Registered databases Database 563 ChartletsBase ENC Update database Professional TestBase Released Path 19 01 2004 1161 C Documents an Ci CERT TEST DA C Documents an C Documents an 18 06 2007 11 11 2008 13 01 2005 This be useful wh
31. follows Value Solution Connect the monitor to a serial port in accordance with Chapter 2 and 3 2 9 Perform automatic or manual calibration as outlined below The manual calibration file loaded does not match the connected monitor Obtain the correct calibration file from your TECDIS support provider and repeat manual calibration The monitor does not contain the correct monitor calibration files Contact your TECDIS support provider Calibration has been successfully performed Verify correct calibration by comparing the monitor model specified in Calibration Name to the monitor model label Calibration has been successfully performed and verified Calibration Name Indicates the name of the currently loaded manual or automatic calibration Monitor Type Indicates the monitor model name as reported by the monitor during the last automatic calibration process Identify Monitor and Load Automatic Calibration Initiates automatic identification of monitor type and attempts to load automatic calibration data from the monitor The possible values seen here are Value Solution Connect the monitor to a serial port in accordance with Chapter 2 and 3 2 9 The monitor is not recognized and manual calibration is needed The monitor is recognized but a manual calibration is needed The monitor ID is shown The monitor is recognized and automatic calibration is performed
32. http www hatteland display com maritime line displays series 1 php Page 24 TECDIS Installation Manual Outline dimensions for JH 23T14 MMD FRONT VIEW 584 00 22 99 568 00 22 36 534 00 21 02 0 6 50 0 26 THRU 5 4 96 281 00 11 06 Area for custom logo BOTTOM VIEW 126 00 85 00 3 35 TOP VIEW 540 00 21 26 14 00 055 71 00 2 80 SIDE VIEW BACK VIEW T 1250 1049 543 00 21 38 p 1250 In 165 00 6 50 583 66001 583 _ 109 80 4 32 12 50 0 49 8 00 10 31 Optional holes 6 50 0 26 THRU 4 places horizontolly PANEL CUTOUT Metric tread M6 or 6 30 0 25 THRU __ 4 places vertically 8 00 0 31 109 80 4 32 505 00 19 88 12 50 0 49 5 148 00 5 83 148 00 5 83 114 20 4 50 6 00 0 24 114 20 4 50 m 6 00 0 24 Dimensions might be shown with or without decimals and indicated as mm inches Tolerance on drawings is 1mm For accurate measurements check relevant DWG file as obtainable from http www hatteland display com maritime line displays series1 php TECDIS Installation Manual Page 25 Outline dimensions for HD 19T03 COBA model shown
33. list of all valid licenses Licenses list and to generate an order file for new licenses License order TECDIS Installation Manual Page 79 3 6 3 Dynamic Licensing TECDIS includes full support of Jeppesen Marine s Dynamic Licensing solution for ENC charts in C MAP SENC format Dynamic Licensing provides a cost effective method for ensuring continual vessel ENC coverage with minimal overhead and administrative costs 3 6 3 1 Traditional ENC Licensing Previously the only way to acquire ENC charts for paperless navigation has been to purchase subscriptions for all ENC charts required by the vessel in advance Activating the ENC charts on the vessel requires license codes to be entered on the onboard ECDIS systems both initially and each time the chart licenses expire Typically each required ENC chart is licensed for a 12 month period regardless of whether the vessel actually makes use of the ENC chart or not 3 6 3 2 What is Dynamic Licensing Dynamic Licensing is a subscription agreement between the vessel operator and Jeppesen Marine that gives the vessel immediate access to ENC charts within the subscription area The subscription incurs no immediate costs to the operator Once the subscription agreement is active the vessel ECDIS systems will provide immediate access to any ENC charts required within the subscription area either for planning or monitoring There is no need to enter any license codes 3 6 3
34. sensors will be connected using the two RS 232 RS 422 serial split cables with 2x4xDB9 connectors attached to the computers Moxa connectors These cables provide COM ports 5 12 labeled on the connector cables as 1 to 8 Ports 4 7 use connector 1 and ports 8 11 use connector 2 as shown in chapter 2 6 3 on page 61 The pin assignments are the same as for HT C01 TEL A596 D596 Moxa serial split cable DB9 male pin assignments Pin No RS 422 RS 232 1 TxD A DCD 2 TxD B RxD 3 TxD ij 4 RxD A DTR 6 DSR 7 RTS 6 9 8 CTS 9 RI All serial ports from COM 4 to COM 11 will be configured as RS 422 ports by default The ports can be reconfigured using Windows Device Manager as described on the following page Page 54 TECDIS Installation Manual 2 3 1 Insert Service Key and exit to windows Open the start menu and go to the following Control panel gt Hardware and sound gt Device Manager Reconfiguration of COM ports on ENIX 2077 TEL D1 oat Device Manager File Action View Help 1 15 In the hardware list that appears in Device Manager open sublevel under Multi port serial adapters Double click on the first MOXA connector to change COM 4 7 or the second to change COM 8 11 In the appearing window go to the tab called ports configuration Then click on the button port setting In the dropdown box under interface select the configuration yo
35. ship s body The protection earth grounding is required to the AC power supply to prevent electrical shock Observe the following compass safe distances to prevent interference to a magnetic compass Standard Steering compass compass HT405P4 TEL A1 2 2m 1 5m HT C01 TEL A599 1 55m 0 95m HT C01 TEL A596 1 55m 0 95m HT C01 TEL D596 1 55m 0 95m HD 24T21 1 15m 0 7m ENIX 2067 TEL D1 0 45m 0 25m JH 19T14 MMD 0 85m 0 45m JH 20717 MMD 0 75m 0 35m JH 23T12 MMD 1 6m 1 05m JH 23T14 MMD 0 6m 0 25m HD 19T03 0 8m 0 5m HD 19721 MMD 1 25m 0 75m HD 24721 MMD 0 7m 0 45m HD 26721 MMD 1 3m 0 7m Furuno MU 201CE 2 25m 1 4m Furuno MU 231CE 2 55M 1 55m ISIC DuraMon 19LED 0 65m 0 35m ISIC DuraMon 26 WS 1 6m 1 1m BTC5100C PS 2 0 3m 0 3m G84 4100LCMGB 2 0 8m 0 6m Keytouch Panels 0 2m 0 25m DNH HP 6 1 0m DHN HPS 6 1 0m Furuno RCU 018 0 3m TECDIS Keypad Logitech Trackman M Page 4 TECDIS Installation Manual TECDIS Installation Manual Page 5 Table of contents TABLE OF CONTENTS lolita lalla GENERAL INTRODUCTION TO THE INSTALLATION 1 9 STANDARDS COMPLIANCE sseseesersrsesereeeeserorseserereeserorseserereesesoreeserereeseroreesesereesesereeseseeereeeee LO INSTALLATION
36. speed Select AIS in the Data type field and check that the Baud TPA field indicates the high speed setting The speed is set by selection from this field s drop down menu 3 2 7 Serial port activity In the Serial port activity field the ports that are receiving data are shown Whenever data is received on a COM port the corresponding indicator in this area will flash green The indicators are for COM ports 1 12 in increasing order from left to right 3 2 8 Received data on selected port In the Received data on selected port field the data that are being received from the COM port that is marked with green in the Information field and selected in the Data type field By changing the selected port in Data type field by selecting one of the other Data types the data shown in the Received data on selected port field will change correspondingly 3 2 9 Other COM port connections All Input ports settings that is not used should be set to Additionally there are some predefined in outputs that may have non NMEA protocol On the HT 01 TEL A 596 and HT C01 TEL A 596 computers used for TECDIS 2138AA and TECDIS 2138AD the serial ports COM 1 and 3 are set as RS232 COM 2 is proprietary and remaining COM ports are RS 422 serial ports Monitor Ctrl Select the COM port RS232 that the monitor is connected to This connection will control the monitor background l
37. supply Page 62 TECDIS Installation Manual 2 7 Other notes regarding connectors and wiring e When the combined keyboard and trackball Keytouch Panel Combo is installed the keyboard and the trackball must be connected separately to the main processor unit using separate USB cables in order to fully comply with type approvals e For unit HD 24T21 MEC the keyboard and trackball should be connected using the included PS 2 adaptors e Ethernet connectors and cable 10BaseT Standard Cable 10BaseT Crossed Cable hit Use standard cable w iring w hen connecting a TECDIS unit w ith Adapter T3232 1 hit gt Use crossed cable wiring w hen Green connecting a TECDIS unit directly with another hit N O o A OU N _ _ _ _ __ on Pin Assignments RJ45 10 100 LAN Pin Assignments RJ45 10 100 1000 LAN 12345678 12345678 01 J Transmit Differential Pair Positive Pin 01 DOP Differential Pair 0 Positive Pin 02 TDN_ Transmit Differential Pair Negative Pin 02 DON Differential Pair 0 Negative Pin 03 RDP Differential Pair Positive Pin 03 DIP__ Differential Pair 1 Positive Pin 04 NC Not Connected Pin 04 D2P__ Differential Pair 2 Positive Pin 05 NC Not Connected Pin 05 02 Di
38. tab settings for connection to autopilots and Track Control can be set Refer to chapter 4 Autopilot Configuration and the OEM Installation Manual for installation and configuration of the autopilot NB The autopilot and TECDIS must be supplied with the same heading and log sensor inputs 3 7 1 Starting Requirements The values in this area specify the conditions needed before Track Control mode can be activated Max course The maximum number of degrees the course over ground COG of the deviation vessel can differ from the planned course Max lane deviation The maximum distance of the vessel position from the planned route leg expressed as a multiplier of the planned route leg lane width For example if the lane setting for the initial planned route leg is 100m and max lane deviation is set to x2 the vessel position can be up to 200m from the planned route leg when Track Control is activated Min speed The minimum speed of the vessel in knots 3 7 2 Default values new route The values in this area will be used as the default values for the parameters specified when planning a new route Speed kn The default planned speed in knots for new route legs Lane x The default planned lane width for new route legs expressed as hundredths of a 0 01 NM nautical mile Le if the value specified is 10 the default lane width would be 0 1 NM Turn The default planned turn radius for new route legs expresse
39. targets Specify time and distance limits for CPA alarms from all targets Show danger CPA allows display of the CPA graphically in the chart If Allow Standby Mode is selected in TECDIS Setup See chapter 3 3 it is possible to disable CPA alarms by unselecting Raise CPA alarm A prominent warning is displayed when CPA alarms are disabled TECDIS Installation Manual Page 89 4 4 Chart library Chart library displays an overview of all charts in a database By selecting a database from the drop down menu a list with all charts in the database appears sorted by publisher Highlight a chart in the list to display further information middle field When double clicking on a chart in the list it will appear if license is present When vessel is sailing vessel is automatically centered if not auto function is disabled NB Chart library only displays databases selected in setup menu folder DataSet filename GBSXO1NE COO Source identification code GBSXOTNE 000 40 000 000 5 000 000 Souree producing agency Hydrographic Office UK 5 000 000 1500 000 ie 1500 000 500 000 Scale 25000 500 000 160 000 GB5XOISW 000 GBEX01SW F Coastal Approach 150 000 50 000 2 Approach 50 000 15 000 Harbor 15 000 5 000 F Plan Mark All Clear All Chart boundaries graphically presents coverage of all charts in the database at present level Levels comply
40. the pull down menu in the nput folder to the right When Data type is selected the corresponding line in the information field to the left is shown as active in blue background color 3 2 2 Info text Then type in a text description in the nfo field to identify the source instrument for the selected Data type This could be brand name for the sensor connected as this field text will be visible in warnings and alerts in the TECDIS program 3 2 3 NMEA sentence In the pull down menu for NMEA sentence select the type of NMEA sentence for this input For more information about the different NMEA sentences see the table in paragraph 3 2 11 below Available NMEA sentences in the pull down menu will change according to which Data type is selected When a given sensor provides more than one of the supported NMEA sentences the highest ranking option from the following lists as applicable should be used Position 1 and Position 2 1 GNS GNSS fix data 2 2GGA GPS fix data 3 GLL Geographic position lat long 4 RMC Recommended minimum specific GNSS data 5 AIVDO AIS own ship position UAIS VHF Data link own vessel report COG SOG 1 and COG SOG 2 1 2 VTG Course and speed over ground 2 RMC Recommended minimum specific GNSS data 3 20SD Own ship data 4 l AIVDO AIS own ship position UAIS VHF Data link own vessel report Heading 1 and Heading 2 1 822 5 Tru
41. with scale selected on the top menu bar Licensed charts are displayed with magenta non licensed charts are marked with black boundary Chart names are presented in the bottom left hand corner of the square 15 000 5 000 5000 m Ta ort 57 Remove Dataset lear an Page 90 TECDIS Installation Manual Remove dataset If a database contains imported S57 data is selected in the drop down menu the button Remove Dataset will delete selected chart WARNING This will remove the dataset GB5XO1SW and all associated updates 000 GBSXOISW EBBXO1SW 000 BS Find Import 857 Remove Dataset 4 5 Import of S57 data NB When two ECDIS machines are connected make sure to make the same updates in the second ECDIS Import of S57 data is done trough the chart library Select database in the drop down menu and press Import S57 A database contains of datasets charts ENC data is sold as ENC cells in 57 format Trough import to a database every ENC cell is converted to a dataset This is a two step process verification of data and conversion compilation to a dataset To import data select drive in the field mport S57 data from Data is imported to a database which name begins with S57 However there are none S57 databases present a new one S57 is created Optional an own database can be created by pressing create new database 57 database is added automatically and can
42. 0 19 29 58100 2287 n BACK VIEW 4xR 400 0 16 PANEL CUTOUT 150 00 591 372 0 14 65 si 156 50 6 16 280 00 11 02 4 4 x M6 thre Vesa mount 9200 362 Flush mounting dimensions Dimensions might be shown with or without decimals and indicated as mm inches Tolerance on drawings is Imm Dimensions for flush mounting along with accurate measurements can be found on the Hatteland website http www hatteland display com panel computer hd24t21 MEC php Page 22 TECDIS Installation Manual 1 13 Outline dimensions for Hatteland Display monitors Outline dimensions for JH 20T17 MMD FRONT VIEW SIDE VIEW BACK VIEW 534 00 21 02 503 00 19 80 o Ft TIT pui 3 6 50 0 26 THRU S 3 1 1 i ii 2 TET fF VEL M n 484 00 19 06 130 05 5 12 5 12 BOTTOM VIEW 1 45 62 1 80 mm 45 62 1 80 _ 15 57 0 61 5 57 0 61 9 50 0 37 i 9 50 0 37 E Optiorial holes 6 5 0 26 screwed from backside panel S 4 places horizontally i PANEL CUTOUT 5 Metric tread M6 or 26 5 0 26 TOP VIEW ES 4places vertically _ 27 00 1 06 480 00 18 90 E
43. 08 2006 Chapter 3 2 1 Updated text Port collision warning case 69 19 04 06 e Chapter 3 4 Updated text and illustrations New function ship handle mode case 53 30 03 06 e Chapter 4 1 New function time zone selection case 98 22 05 06 Revision 1 5 22 10 2006 Chapter 3 2 Updated illustration Chapter 3 2 6 Added description of RCU 018 ctrl field Chapter 3 4 Updated illustration Chapter 3 5 Updated illustration Chapter 3 6 Updated illustration New Chapter 3 7 Track Control Compass Safe Distance table on page updated Equipment Lists on page 5 updated Installation Overview illustration updated Specifications updated Updated mounting section Added mounting Chapter 1 3 Control Unit Furuno RCU 018 Added Chapter 2 1 HT405P4 Wiring diagram Added Chapter 2 3 Processor connectors HT405P4 TEL A1 Renumbered chapters following 2 1 Revision 1 6 30 04 2007 e Compass Safe Distances on page 1 updated Equipment List on page 5 updated Installation Overview illustration updated Specifications for HT 405P4 on page 7 updated Specifications for JH 23T02 on page 8 added Mounting dimensions for JH23T02 added to chapter 1 1 page 17 and 18 New chapter 1 6 Track Control Anschiitz NP 2025 PLUS Revision 1 7 17 10 2007 e Section 2 5 Processor connectors HT405P4 TEL A1 on page 37 updated with information about ferrite placement e Section 3 2 NMEA data setup on page 41 44 updated with new illustration and information about status
44. 3 Credit Limit To prevent uncontrolled licensing costs the subscription agreement includes a yearly credit limit based on estimated yearly costs for the vessel When an ENC chart is licensed by the ECDIS system the licensing cost for the chart is subtracted and the credit limit is reduced accordingly This credit limit can be extended whenever needed 3 6 3 4 Automatic licensing When the vessel requires access to a new ENC chart the system immediately activates a 3 month license for the chart If the vessel again requires access to the same ENC chart after this period a new 3 month license is activated This means that an ENC chart subscription is only purchased at the time the vessel actually requires the chart and the 3 month licensing period ensures that no subscription costs are incurred when the vessel has no need for the chart 3 6 3 5 Reporting usage The activated ENC chart licenses are automatically reported back to Jeppesen Marine whenever the vessel uses the C MAP Update Service Online to download corrections to the ENC charts Since the chart update process is required for paperless navigation this does not require any additional work for the bridge personnel Some Hydrographic Offices requires 12 month subscription periods for all of their ENC charts For these charts 12 month licenses are generated Page 80 TECDIS Installation Manual 3 6 3 6 Invoicing Based on the reported actual ENC chart usage Jeppes
45. 5 aS o ce 252 SS oc zd zee To ca e f SA N oz mg min 3x2x022mm shielded max 150m ALARM INTERFACE Telko TEA 01 230VAC Supplied Cable Some models with Supplied Cable or Good Quality VGA Cable max 15m R_VIDEO lt 1 1 gt R_VIDEO G_VIDEO 2 gt iG_VIDEO MANDATORY Position Heading COG SOG TRACK CONTROL MANDATORY Raytheon Ansch tz NP2025 PLUS L0 131 2202 XIN3 3920 SIGOSL YOLINOW 9NINNOO OPTIONAL Alarm Central Water Speed ARPA Radar Cursor Depth Rel Wind Route AIS APB Out RMB Out min 2x022mm shielded RMC Out max 150m RTE Out Attached 1 213 5 2 Cable 1081 A9 0 exo 001 80 GHVOSA3M LAN SWITCH connected to DUAL SYSTEM MANDATORY OTHER TECDIS esno A TIVEMOVUL OPTIONAL Furuno FAR 2xx7 Radar Furuno 8530 Remote Junction box AM ESLAN PAT Jeyiduuv oipny S SdH 9 dH HNG YayVads Page 58 TECDIS Installation Manual 2 5 Signal distribution diagram internal data flow PRIMARY TECDIS ADDRESS 172 31 3 61 Optional Furuno RCU 018 Optional Alarm Interface TEA 01 Com I only zi n PE R Mandatory Position Heading COGNX Monitor Control TECDIS Radar
46. 86 4 1 4 1 1 4 2 4 2 1 4 2 2 4 2 3 4 2 4 4 2 5 4 2 6 4 3 4 3 1 4 3 2 4 3 3 4 3 4 Sdn eec EE E E I E E OO SHOW SHIP OUTLINE DAA E I E EE E EE I ES 87 COURSE VECTORS nesei e rit 87 W HEELOVER emt 87 Operational parameters for AIS 4 eese eee eee eee ee eee eee eee OO DISPLAY FILTER RANGE AND TRACK EEN STIE eaea 88 DISPLAY FILTER ALL TARGETS ACTIVE 88 DISPLAY FILTER HIDE CLASS B ee RO PEE ERE 88 DISPLAY FILTER RELATIVE COG VECTORS 88 TECDIS Installation Manual Page 7 4 3 92 EOST ACTIVE TARGETS Re ueque IE 88 4 3 6 DANGER CPA ALE TARGETS Wo eet eter eure tente oerte aio eter e deter v ve een enero dee tert 88 library c 89 4 5 90 4 6 Import of 5 63 chart data 91 CHAPTER 5 MISCELLANEOUS iraniane 92 5 1 Error 92 52 Monitor Calibration adi iaia 93 5 3 Internet VSAT connection troubleshooting
47. CD DVD TO USB FLASH 74 ENTER VESSEL INFORMA TION Uri EC ER TR ERE EYES 74 SEND t pes iecore 74 START CMAP CHARTMDANAQGER 75 MONITOR CALIBRATION AND 8 URLO OR UA 75 UNG H LICENSE dinner 77 iC 2M AR LICENSEES 145 he Poche Lt leo a 78 DYNAMICEEIGENSINGS tus 79 USING DYNAMIC LICENSING IN TECDIS 80 Track Control ct echo erbe eR ee tar eter adi STARTING REQUIREMENTS 5 eter perito eee e 82 DEFAULT VALUES NEW ROUTE oed FO ee nee 82 OTHER I AA ORT RM a 83 AUTOPILOT SPECIFIC SETTINGS FOR ANSCHUTZ 2025 ONLY SHOWN WHEN AVAILABLE 83 AUTOPILOT SPECIFIC SETTINGS FOR ANSCHUTZ NP5500 ONLY SHOWN WHEN AVAILABLE 83 Route SYNCHrOni Zac M BASIG METHOD i253 cM 84 AUTOMATIC METHOD REPLICATION ore teea r areena eor eaae EERE oea E Ep E AEO E ER EEr eseat 84 Alarm source setting orientati iaia lio OD CHAPTER 4 OPERATIONAL SYSTEM 58
48. D Pixel number 1920 x 1200 Pixel pitch RGB 0 2865 mm H V Response time 8 ms Contrast ratio 1500 1 Light intensity 400 cd m2 Viewable angle 88 deg L R T B Display area 550 08x344 8 mm H V Auto detects VGA to WUXGA Input signal DVI 24pin Input signal RGB 15 HD D SUB Control input output RS 232 D sub 9pin Power 90 264 VAC 50 60 Hz 125 W typical Weight 12 kg approx HW revision number Part no 05226 xxx Keytouch Panel QWERTY Flush mount QWERTY keyboard 85 short travel switches Polyester with key embossing Key switch lifetime 200 000 operations IP22 protection level Connection USB type B Dimmable backlight Light sensor for backlight and LED dimming Dim 321 2 W x 196 H mm Cutout 301 W x 176 H mm Logitech Trackman Marble Desktop placed trackball Connection USB PS 2 adapter included Ball diameter 38mm Ball reading Optical 4 switches programmable Dimensions 96 x 160 mm Page 18 TECDIS Installation Manual Mouse Trak B MPIND XROHS Functional Specifications Resolution 192 to 576 pulses per revolution of the ball Input Switches Three 3 Interface IBM PS 2 Connector 6 Pin Mini DIN Male Pin Assignments Pin 1 PS 2 Data Pin 2 NC Pin 3 Common Pin 4 5V Pin 5 PS 2 clock Pin 6 NC Compatibility Microsoft PS 2 Mouse Protocol Logitech PS 2 Mouse Protocol Switches Mechanically limited break resistant Cable 96 0 5
49. D R W Dual 48x 16x 6x 8x 4x 10 100 1000Mbps Ethernet LAN x RS 232 Serial Port 8 ports optoisolated RS 232 RS 422 serial interface MOXA CP118U I 1x Furuno RCU 018 Connector 1x Parallel Port 10x USB 2 0 ports e Standard PS 2 keyboard amp mouse Dim 345 W x 133 H x 390 D mm TEL A596 110 230V 330W 70W typical TEL D596 24 VDC 220W 70W typical Monitor JH 20T17 MMD 20 1 inch viewable image size A Si Thin Film Transistor Active matrix Pixel number 1600x1200 Pixel pitch RGB 0 255 mm H V Response time 20 ms Contrast ratio 700 1 Light intensity 300 cd m2 Viewable angle 85 deg H V L R Active display area 408x306 mm H V Optimum picture with 60 Hz Input signal DVI D DVI D input 24pin Input signal RGB 15pin mini D sub Input signal Multifunction AC power 115 VAC 60 Hz 230 VAC 50 Hz 100 W max Weight 13 5 kg HW revision number is part of model number Processor with integrated monitor HD 24T21 MEC Compact high end industrial computer with integrated monitor and Microsoft Windows 7 ntel Celeron P4505 1 86 GHz Intel HD Graphics integrated graphics processor 2GB RAM 4GB Max HD SSD 80GB 2 5 Hard drive 4x USB 1x USB 1 1 3x USB 2 0 ports Standard PS 2 Keyboard and mouse 4 ports optoisolated RS 422 485 serial interface via USB internal Phoenix Spin ports 1x RS 232 serial port amp 1x RS 422 485 serial port 24
50. FAR 2xx7 series radar e LANconnector LAN 2 Internet can optionally be used for connecting the TECDIS unit to other networks or internet To fully comply with type approvals when connected to internet a switch must be made available to disconnect TECDIS from internet when the connection is not in use e NOTE This unit has a multi power supply where power input can be selected between 110 230 VAC or 24 VDC TECDIS Installation Manual Page 61 2 6 3 ENIX 2077 TEL D1 Moxa Connector Moxa Connector COM 4 7 COM 8 11 E 24 VDC POWER 775 e Configuration of serial ports connected to the two Moxa connectors can be found on page 53 50 e COM 1 is to be used for TEA 01 Alarm central interface ECDIS monitor control may be connected to COM 1 or COM 2 directly e Connect ECDIS monitor using the DVI I connector e If optional speaker is used for buzzer then connect speakers to the Loudspeaker connection on the Audio Amplifier card Lyd UK153 optional e LAN connector LAN 1 Furuno is to be used when connecting the TECDIS unit to other TECDIS units Furuno VDR Adapter or Furuno FAR 2xx7 series radar e LANconnector LAN 2 Internet can optionally be used for connecting the TECDIS unit to other networks or internet To fully comply with type approvals when connected to internet a switch must be made available to disconnect TECDIS from internet when the connection is not in use NOTE ENIX 2077 TEL D1 uses 24 VDC for power
51. I IAN 1 196 i I 1 mE i 7 i 1 C O i i cutout 186 mm a a Sn I i i O gt 7 04 DEL LJ 1 n EP B 1 MN i x 1 bout eli LL cutout 114 mm M4 countersunk TECDIS Installation Manual Page 45 1 5 Additional units When mounting additional units such as loudspeaker analogue alarm units MOXA interface and other peripheral equipment general considerations should be taken to ensure proper functions of respective equipment When selecting a mounting location keep in mind the following points 1 Selecta location where vibrations are down to a minimum try to avoid vibrations by adding strength to console where the processor is about to be installed 2 Locate the unit away from heat sources because of heat that can build up inside the cabinet 3 Locate the equipment away from places subject to water splash and rain 4 Leave sufficient space on the sides and rear of the unit to facilitate maintenance and interconnection cabling 5 Mount the loudspeaker such that audible sound level is not seriously degraded Do not protrude the housing with screws to fasten the units Straps should be used to fasten the units at its location without protruding the housing Straps are not supplied and must be arranged locally 1 5 1 Outline dimensions for ala
52. IS Installation Manual ver 2 7 and above Fill in hardware software fact sheet and file it in ships documents in technician personal files and send a copy to Furuno Norway or Telko AS A N nN oo 10 TECDIS Installation Manual Page 97 Sesto si ST kowa E E Du CC I mamma mamma ST aveste T_T Dm onto men ST monto e ST coin mesi ST cine mio Ex meme E Dx ST auromor D mew O E x T_T mesmaw _T D pmi EX TSZ files tsz tecdis no Vessel Name ID Date of installation Name of technician and company Checklist performed Sign This checklist shall be filled in and signed for all TECDIS installations in order to verify proper installation of the ECDIS system onboard 10 Make sure the hardware revision number match the specification see page 11 14 in TECDIS Installation Manual ver 2 7 Page 98 TECDIS Installation Manual 6 2 Checklist prior to completion of TECDIS TCS and TECDIS AW installation If installation includes Track Control functionality the following tests must be performed TECDIS 1 and 2 No Function Requirement Results Harbor Acceptance Test 15 minutes TECDIS 1 Go to setup menu and verify NMEA
53. IS unit See section 3 3 Specification 2 The TECDIS units must be connected using the specified LAN adapter ports 3 The LAN adapter port used for connection between the TECDIS units should not be reconfigured to use an IP address outside the subnet 172 31 3 4 Replication The TECDIS units must use unique license dongles Telko eToken ID numbers must be different NOTE The automatic method is activated by default in all TECDIS units produced after 1 November 2008 3 8 1 Basic Method When the basic route synchronization method is in use and a route is activated on either of the TECDIS units a backup copy of the route is transferred to the other TECDIS This backup is not automatically included in the route list on the receiving TECDIS unit but it can be imported when needed The route is available for import from the following files in the Data subdirectory of the TECIDS directory C Program Files TECDIS Data Primary Route ReceivedPrimaryRoute st Secondary Route ReceivedSecondaryRoute st 3 8 2 Automatic Method Replication When Replication is activated all new routes entered changes to existing routes and removal of routes is automatically reflected at the other TECDIS unit In effect the two TECDIS units will contain identical route databases Auto replication of planned routes x ROUTE REPLICATION IMPORTANT ACTIVATION NOTE With Two TECDIS computers in network Both accessing the othe
54. Overlay Data Corg Backup ink to S eder 8 Track Control Mandatory Backup bn from other TECDIS Ansch tz NP 2025 Plus Autopilot Fyruno FAP 2000 Autopilot EMRI SEM 200 Autopilot D 2 Optional NMEA Water Speed SERVER y 3 ARPA Om Radar Cursor ou Depth ma Rel Wind Zo E fe pm AIS APBRMBRMCRTE Out l Furuno FAR 2xx7 series Radir gt 1 ANALOG INPUTS 1 DIGITAL INPUTS Optional Furuno RCU 018 Optional Alarm Interface TEA 01 Com 1 only DT Mandatory Position Heading COGSOG Monitor Control SETUP TECDIS t INOO B WOO Track Control Mandatory Ansch tz 2025 Plus Autopilot Fyruno FAP 2000 Autopilot EMRI SEM 200 Autopilot Optional it Water Speed Il ARPA 5 Radar Cursor 2 2 Depth vi Mal Rel Wind pa i M Route Le AIS APBRMBRMCRTE Out Ir 86 WOO SECONDARY TECDIS ADDRESS 172 31 3 62 TECDIS Installation Manual Page 59 2 6 Processor connectors Select the appropriate installation procedure for your chosen processing unit e For HT 1 processors continue to chapter 2 6 1 below for wiring diagram e For HD 24T21 MEC processor continue to chapter 2 6 2 on page 60 For ENIX 2067 TEL D1 processor continue to cha
55. Reformatting all heading numbers and new Table of Contents e Chapter 3 2 NMEA Data setup is rewritten to comply to new version of TECDIS Setup Chapter 3 3 Specification is updated to describe the changes related to the Alarm field and changes introduced by the functionality of the TSZ files e Chapter 6 1 Checklist requirement added for sending in TZS files and added need for the technician s company name to be filled in e Chapter 6 2 Checklist updated with two new Autopilot types Furuno and EMRI Revision 2 5 17 09 2012 e Chapter 1 7 Instruction to set same low speed limit value in TECDIS and Autopilot added e Chapter 3 Several minor fixes Revision 2 6 23 08 2013 Page 110 TECDIS Installation Manual Compass safe distance Equipment list Installation overview Specifications and Chapter 1 are expanded and updated to include o new computer HD 24721 o new displays HD 19T21 HD 24721 HD 26721 ISIC DuraMon 19LED and ISIC MD 26 05 also referenced as DuraMon 26 WS Reformatted sub headings and new Table of Contents Specifications added specifications for Cherry G84 4100 keyboard Chapter 1 New subchapters for outline dimensions of monitors and computers Chapter 2 1 2 3 New subchapters for computer specific wiring and signal distribution Chapter 2 6 1 2 6 3 New subchapters for computer specific I O connections Chapter 3 Several minor fixes Chapter 3 5 5 Updated with new monitor calibration feedback m
56. S 1 the Plan key icon with number 1 indicated is active This means primary route will be selected Choose a route with boathook icon Press YES icon to activate route 3 Route is then shown on displayed charts A To display secondary route choose icon with button 2 indicated Repeat procedure as for primary route b To exchange primary and secondary route press icon with 162 indicated 6 Observe that correct warnings is activated as appropriate 9 Test that activating track steering is successful 7 Click alarm icon for display of alarms and warnings on route TECDIS 1 L1Good LING LIN A TECDIS 2 L1Good LING LIN A TECDIS Installation Manual Page 99 TECDIS 1 Radar overlay Check that radar overlay from radar is displayed on display after L1Good LING LIN A If present pressing radar overlay icon TECDIS 2 L1Good LING CIN A Verify that TECDIS handle different functions like 1 Disconnect position sensors and observe dead reckoning performance verify that alarm is given pos sensor lost 2 Activate track dialog and set past tracks visible by clicking on show icon 3 Enter manual fix by activating bearing icon Click on center button on mouse when mouse is in position of visual object Use observed gyro bearing to make a red line in chart towards estimated position Repeat procedure to make two lines resulting in a cross bearing 4 Update charts enter
57. S Installation Manual Page 41 1 4 2 Outline dimensions and cutout for Keytouch panel OWERTY Roe Si o lA xt o gt 321 2 J 41 0 119 6 119 6 n ta SUS to e a 5 3 0 tr Possible CUT OUT 8 9 292 0 36 2 119 6 119 6 36 2 T i 1 5 311 5 9 9 290 0 2 36 2 119 6 119 6 Fa S 2 4 e 5 2 5 tn 2 0 1 Page 42 TECDIS Installation Manual 1 4 3 Outline dimensions and cutout for Keytouch panel Trackball 169 0 114 3 89 0 ei amp a ee rl A j N sil 1 1 1 1 1 O QL Possible CUT OUT TECDIS Installation Manual Page 43 1 44 Outline dimensions for Keytouch panel Combo F3 ma m 165 5 1 ot rs 7 Ld 6 413 0 a 165 5 IRRGRGCOROARO oraz 41 0 Page 44 TECDIS Installation Manual 1 4 5 Outline dimensions for TECDIS Keypad 124 mm Light sensor c DES QE Area with backlight ic NEN LJ ibi Indicator LEDs Tg 1 4 Embossed button i J _ Foil edge DTT ASS 2 S 1 I umm o ec I
58. a connection to the IP server with the selected address port number and the Received data on selected will show any data that is received The log button allows you to create a log of the NMEA sentences read by the TECDIS Unit Example In order to receive position data from a GPS you need to 1 Select Position I or Position 2 from the Data type pull down menu 2 Optionally but recommended enter a description identifying the sensor as a GPS in the Info field If the sensor signal is lost while the TECDIS is in operation an alarm will be sounded The alarm message will indicate the type of sensor lost as well as what port it is connected to and the sensor description from the Info field The failing instrument instead of having to refer to the configuration in the Setup program is easily identified NMEA Sensor inputs and status can also be displayed in TECDIS 3 Select the NMEA sentence from the NMEA sentence pull down menu TECDIS Installation Manual Page 67 4 Select the Jnput port for the GPS from the Input port pull down menu 3 2 6 The Baud TPA field In the Baud TPA field the data speed to be used for the COM are set The NMEA standard is 4800 low speed Be aware though that some instruments require a different data speed selection ISIC monitors use 19200 baud There is also a NMEA high speed standard 38400 AIS units typically use high
59. a current limited 6 8 Kohm resistor opto coupler MCT5211 Reset in at 10 30 VDC All input and outputs are electrically isolated Shield shall be connected at alarm central side Shield are connected in Dsubmin 9f connector but are not cross connected in the interface box A 1 5 m Cable with Dsub mini 9p female PC serial port in one end and an interface box with 7 screw terminal in the other end Wiring info 1 Alarm Out NO 2 gt Alarm Out NO 3 Sound Alarm out reset NO 4 gt Sound Alarm out reset NO 5 Sound Alarm inp Reset NO 6 lt Sound Alarm inp Reset NO 7 Cable shield Page 20 TECDIS Installation Manual Chapter 1 Mounting 11 Monitor Unit The monitor unit can be flush mounted in a console panel or mounted on desktop using optional accessories When selecting a mounting location keep in mind the following points 1 Select a location where the display unit can be viewed conveniently and where the screen can be viewed while facing towards the bow 2 Select a location where vibrations are down to a minimum try to avoid vibrations by adding strength to console where monitor is about to be installed 3 Locate the unit out of direct sunlight and away from heat sources because of heat that can build up inside the cabinet 4 Locate the equipment away from places subject to water splash and rain 5 Leave sufficient space on the sides and rear of the unit to fac
60. and Ground Speed Receive VWR Relative Apparent Wind Speed and Angle Receive PL Waypoint Location Send Receive DA Time and date Receive lt lt N NOTE TECDIS also supports a number of proprietary protocols for specific application areas Contact your TECDIS supplier for details Page 70 TECDIS Installation Manual 3 3 Specification On this tab the dimensions of the vessel and the placement of sensors on the vessel are specified Specifying the position of the sensors is important in order to get the highest possible accuracy in position GPS antenna and other data as possible Nmea Data Ship size m LENS Length di ps Beam 3 Draught min Bo 5 Draught max b 3 Safe dpt min Height Chart Installation Misc Licensing Track Control Position sensor 1 5 from bow 404 center gt starbrd Position sensor 2 2 m from bow 2 m center gt starbrd Conning position 82 E m from bow b 4 m center gt starbrd 5 m height Depth transducer 2 m from bow 5 above keel Radar antenna 1 18 E m from bow IN m center gt starbrd Radar antenna 2 5 5 m from bow b 4 m center gt starbrd ver 17 22 Other TECDIS station s data export Name IP Name IP This unit is TEGDIS8 Cor above Radar use true EBL reference Arpa
61. ation file for transfer to Greate Furuno Norway or Telko AS Miscellaneous Start C Map Chart Manager If a different section is visible when opening the Chart Installation Misc folder the Cancel or Back buttons can be pressed to access the front page containing the Status field 3 5 1 Install update or remove chart databases Charts are installed using a CD DVD drive If the unit does not contain a CD DVD drive the charts can be loaded using an external CD DVD Copy Chart Database to Harddisk Insert the chart CD and follow the instructions that appear drive with USB interface or by transferring the charts to a USB flash drive Procedure for transferring to USB flash drive can be found in subchapter 3 5 2 By clicking a new area with an overview of installed chart databases is opened Insert the CD DVD for the chart database that is to be operated on and select the CD DVD drive from the drop down menu below the database list The Setup program will read the CD DVD and display the available actions for the chart database Install Update Remove and Set as Default AN are locked to a specific edition of the chart database If a different edition of the database is installed new licenses must be acquired Subscription licenses remain valid when newer chart database editions are installed Important Purchase chart licenses Installed Databa
62. awing Fix the control unit with four screws M4 from under side of the desktop The M4 screws with a sufficient length for the thickness of the desktop should be provided locally Flush mounting Use the optional flush mount kit Furuno FP03 09870 to mount the control unit to a console panel Name Flush mount kit Type Furuno FP03 09870 Code No 008 535 630 No Name Type Qty Mount plate 03 163 7531 4 Hex bolt M4 4 Wy Ny rR Wing screw M4X30 4 Prepare a cutout in the mounting location as shown in the outline figures Set the control unit to the cutout Attach the mounting plate to the control unit with four screws from the rear side Screw the wing screw to each mounting plate and then insert hex bolt to each wing screw Fasten each wing screw and then fasten the hex nuts as shown in the outline figures DS available for the HT C01 processor units Page 38 TECDIS Installation Manual Furuno RCU 018 Control Unit outline Desktop mount TO PROCESSOR UNIT TT 1 All figures in mm TECDIS Installation Manual Page 39 1 4 Keyboard and trackball Keyboard and trackball must be mounted close together such that both can be operated simultaneously by one person When selecting a mounting location keep in mind the following points 1 2 3 4 5 Select a location where the control unit can be operated conveniently Locate the unit a
63. be highlighted for viewing in setup menu folder Enter a name for the new Database 57 1 Cancel Chart Catalogue Stant Create new Database Close Disable error report Instituto Hidrogr fico de la Marina Spain Hydrographic Office UK c Lokal disk E Loira uu 2 CO RW stasjon F Hydrooraohio and Oceanographic Department Japan amp Hydrographic Service Maritime Administration of La MP3 disk p Veogpo2 63 Hydrogranhio Service Royal Netherlands Navy lt 2 portabla p pkstue Find Remove Dataset When drive is selected the start button is activated Press the button to commence import Data is automatically verified TECDIS Installation Manual Page 91 Coast Hydrographic Office Belgium Chart S Kopi PL2 1 S57 GOODB1 ENC_ROOT GBSXO1NW 000 Bundesamt f r Seeschiffahrt und Hydrographie critical errors Kort amp Matrikelstyrelsen Denmark Loading chart di PE rr Error L60147 T1565 open border of ndare 82 29 08 27 S 60 54 42 48 E Error L60147 11565 open border of ndare 32 29 02 78 60 54 45 28 E Error L60147 T1565 open border of Indare 32 29 85 24 8 60 57 48 13 E Hydrographic and Oceanographic Department Japan L60147 T1565 open border of ndare 32 29 35 07 S 60 57 48 70 E Hydrographic Servioe Maritime Admin
64. both bug fixes and new features free of charges at our website http www telko no Your problem may be due to a bug in the software that we have fixed in an update TECDIS Installation Manual Page 95 INTERNET CONNECTION G Make sure that the internet connection is not turned off In a valid TECDIS installation with a direct internet connection a switch has been installed so that the internet connection can be turned off when not in use Weather Try setting a higher Connection Timeout The download attempt may be timing out before the request can be completed Refer to weather overlay documentation section 1 2 step 6 for details Verify that you can reach the servers Exit the chart system For TECIDS insert the TECDIS Service Key first open Internet Explorer and try the following addresses If the reply does not match what is indicated in this table you are not reaching the weather service servers http distribution c map no Should show Connection OK http datacenter c map no http datacenter jeppesen com If test I failed see if you can reach the servers using IP addresses Continue where you left off in the previous test Try the following addresses and see if the replies match what is specified in the table http 80 239 21 75 Should show Connection OK http 80 239 21 103 If these tests succeed the problem is with your DNS Settings If you have not performed
65. chart utilities menu choose C Map TECDIS 1 Aids to charts update Use semi auto update Create a update Good LING ON A navigation request file on memory stick TECDIS 2 Send file to updates c map no and load received file into Good ONG ON A TECDIS Update loaded successfully shall be presented when update Is completed b Activate a route in route menu To alter at route underway click on Edit icon in route menu Modify route and click on OK icon Route is now altered When at track steering mode 3 waypoints are not allowed to alter last waypoint next waypoint and waypoint after next 6 Manual adjustment for position is available in setup menu click on nav position offset icon and a dialog box appear in top right corner of map Enter offset values as appropriate Page 100 TECDIS Installation Manual Autopilot type tick one box only Ansch tz NP 2025 PLUS Adaptive Autopilot Furuno FAP 2000 Autopilot EMRI SEM 200 Autopilot O Ansch tz NP5500 Autopilot Function Requirement Results Harbor Acceptance Test 15 minutes Correct number is shown at each box of below Heading Speed 1 HEADING CONTROL is activated when steering mode switch is set to auto Present heading is displayed in heading display and in preset heading display Present heading is activated as set heading 2 Verify parameter settings for rudder yawing counter rudder rudder limit ROT limit and radius va
66. d as tenths of a radius x nautical mile Le if the value specified is 5 the default turn radius would be 0 5 0 1 NM NM TECDIS Installation Manual Page 83 3 7 3 Other settings Autopilot This field shows which autopilot is selected Autopilot is selected in the NMEA Data tab where further configurations should be made Only the type approved autopilots according to the certificate should be installed and configured to work with the TECDIS Min allowed turn radius x 0 01 NM This setting specifies the minimum turn radius allowed expressed as hundredths of a nautical mile This value should be determined during vessel sea trials Max allowed WOL distance x 0 01 NM This setting specifies the maximum value allowed for operator selected Wheelover Line WOL distance expressed as hundredths of a nautical mile WP warning and alarm time This setting controls how long before a waypoint warnings and alarms are generated Alarm limit difference primary and secondary heading This setting controls the number of degrees the primary and secondary heading sensor values can differ before an alarm is generated If the two heading sensors differ by more than this value an alarm is generated in TECDIS Alarm limit difference primary and secondary position x 0 01 NM This setting controls the distance allowed between the two position sensors before an alarm is generated expressed in hundre
67. deplug 452020 5 6 1BESh Oh eT x un Optical bearing interface License Ver Subver Feature Feature Weather display and routing Dynamic objects Enter password for licensetype and click Program im Radar overlay Password Program 8 TELeodes v 1 2 eT 6 TELKO A S Page 78 TECDIS Installation Manual 3 6 2 C MAP License Add licenses manually Select the zone or area you have received a license for in the window to the right under Data set or Area name 16 character license code is entered in the License string field Finally click on Add License to activate the license C Map License Add License manually Data Set or Area Name Get expired licenses Licenses list Zone 0 Zone 1 Add Licenses from file Zone 2 ni License string oO i Add License Add license from file Use this option if you want to use a supplied password usr file to activate chart licenses browse to the location of this file and select it and press OK The licenses contained in the file will be automatically activated C Map License System ID Telko eT 00005 Local Disk C ATI Code Documents and Settings Dos In this area it is also possible to get a list of licenses that are expired and no longer valid Get expired licenses to see a
68. dths of a nautical mile If the distance between the positions reported by the two position sensors is larger than this value an alarm is generated in TECDIS 3 7 4 Autopilot specific settings for Anschutz 2025 only shown when available 7 Anschutz 2025 80 min E max Remote Control ROT Remote Control panel is visible in TECDIS when AP connection External is active Max Remote Control ROT This setting specifies the maximum rate of turn ROT value allowed in the autopilot remote control panel in TECDIS expressed as degrees per minute 3 7 5 Autopilot specific settings for Anschutz NP5500 only shown when available Anschutz NP5500 14 7 Pivotpoint value set in AP is used to set wol distance in TECDIS COM9 Output port common position SGPGGA nmea to Output port This specifies the output port on the TECDIS unit that sends GPGGA to the autopilot Any COM port with available output capacity can be set up for this purpose Page 84 TECDIS Installation Manual 3 8 Route Synchronization TECDIS provides two alternative ways of transferring routes between the primary and secondary TECDIS units Both solutions allow the operator to retrieve the planned route for the current voyage on the secondary TECDIS unit if the primary unit fails For this function to work correctly the following must be observed 1 The Setup field Data export IP must contain the correct address to the other TECD
69. e SASS Operation and Installation Manual 4 for installation of SASS gt gt Location of change over controls The steering mode selector switch or override facility if installed shall be located at or in the immediate vicinity of the main conning position Connection to TECDIS The NP5500 Autopilot Interface Unit must be connected to a TECDIS serial port and configured in TECDIS SETUP See chapter 3 7 The NP5500 Autopilot must be set up to receive GGA NMEA data from TECDIS only and therefore the connection has to be setup with both transmit and receive for both units The GGA NMEA data from TECDIS sends the CCRP position Due to this the position given by the GPS and given by the TECDIS may be different The CCRP used in TECDIS is the conning position and all output is recalculated to originate from the CCRP Page 50 TECDIS Installation Manual Autopilot installation settings Some settings for the NP5500 Autopilot will be needed for proper setup of Track control These are listed in the table below Chapter number in Operator Unit Service Manual Setting name Configuration description important notices 3 1 2 23 Position from NP5500 Autopilot must be set up to ECDIS receive GGA NMEA data from TECDIS so this must be set to Active 3 1 2 37 Track scale This has to be set after Heading Control is optimally adjusted 3 1 2 40 Drift freeze This must be set in accordance with the Pi
70. e heading and status 2 HDT Heading true 3 892050 Own ship data 4 822 Water Speed and Heading 5 AIVDO AIS own ship position UAIS VHF Data link own vessel report Radar ARPA 1 and Radar ARPA 2 TTM Tracked Target Message Radar Cursor 1 and Radar Curson 2 RSD Radar System Data AIS AI AIS UAIS VHF Data Link 7 Position AIVDO may be used as a secondary position source whenever primary source is missing AIVDO is not available for Position 1 Page 66 TECDIS Installation Manual Depth 1 DPT Depth 2 DBT Depth below transducer 3 2 4 Input port In the pull down menu Input port select the physical serial port the selected sensor Data type should be read from If the nput port field is set to same value as already set for Monitor ctrl Alarm ctrl or Control unit the text of the corresponding lines in the information field will turn red This indicates that the port selection is invalid and that another COM port must be selected either for the sensor or the conflicting equipment The text of the corresponding line in the information field will turn green when valid NMEA sentences is received on the specified Input port 3 2 5 IP port TECDIS TELchart ECS Setup local Ip 172 31 9 71 192 168 0 103 Nmea Data Specification Chart Installation Misc Licensina Track control Input output Data baud TPA
71. e routes were kept will be automatically transmitted to the other TECDIS All further route changes are automatically reflected on the other TECDIS Deactivating Replication If the replication feature needs to be deactivated follow these steps 1 On both TECDIS units insert the Service Key and exit to Windows 2 On both TECDIS units delete the file C Program Files TECDIS SetRtReplicateActive txt 3 On both TECDIS units remove the service dongle and reboot the system 3 9 Alarm source setting Contact your TECDIS support provider for information on changing alarm source settings All alarm sources are activated by default and they are e pc loudspeaker connected to the computers audio amplifier e monitor buzzer in the screen keyboard buzzer in the Furuno RCU 018 keyboard only compatible with HT CO1 units Page 86 TECDIS Installation Manual Chapter 4 Operational system settings Pi When pressing the menu folder button in the top menu bar menu folders will open in the lower part of the side menu field There are 7 different menu folders Data Log Safe Setup Chart Ship and AIS The menus are separated in a folder system where of the folders is displayed at a time Select the desired folder by pressing a folder title Log Safe Ais 41 Setup Setup Chart Ship Data This folders contains Ship draught fiom 5 Nmea input status Nav position offset C
72. e viewed selecting actual dataset in the chart library by scrolling down to S57 import log in the information field If the import of chart corrections is done in S57 format those can be viewed in C Map chart update By pressing the right mouse button in the message field log files with information history about file verifying and compilation are displayed This is a overview not a detailed report log not displaying any deleted datasets 4 6 Import of S 63 chart data For import of chart data in the 5 63 format refer to S63 Loader User Guide available for download from http www telko no Page 92 TECDIS Installation Manual Chapter 5 Miscellaneous 5 1 Error Messages TECDIS includes automatic error detection in most functions If it is possible corrective measures will be taken without requiring operator intervention In case of critical errors the operator is notified In addition to the possible error situations listed here both the Windows operating system and support routines may in some instances display error messages not listed Common to these error messages is that corrective measures if possible are initiated by restarting the ECDIS In the case of a system failure any error messages should therefore be noted If the ECDIS is not responding or appear to be malfunctioning try restarting the ECDIS If this does not correct the error situation notify your support contact 10 Init required too much space Memo
73. ed at C Program files TECDIS dta4 setup or C Program files TECDIS Telchart ini if present Please note the following All position inputs to TECDIS from all external sensors must be in WGS 84 datum If connected to internet to provide C Map Update Service functionality a switch must be made available to disconnect TECDIS from internet when C Map Update Service functionality is not in use Checklist to verify the proper installation of the TECDIS shall be filled in and filed onboard For TECDIS TCS and TECDIS AW a copy of this checklist shall be sent to Telko AS for full type approval compliance For all versions of TECDIS it is strongly recommended that a copy is stored in the installer s archives and that a copy is sent to Furuno Norway or Telko AS Refer to Chapter 1 and Chapter 2 for installation requirements and or limitations for specific hardware components It is recommended that TECDIS is supplied by UPS uninterrupted power supply 220VAC or emergency power this should include also TECDIS backup if installed and other hardware related to the TECDIS installation A dedicated UPS should be supplied to each TECDIS if dual installation The UPS or emergency power should have sufficient capacity to supply all required equipment for a period of at least 60 seconds Page 10 TECDIS Installation Manual Standards Compliance TECDIS conforms to the following standard s or other normative documents Version 4 7 1 and
74. edback input angle is 5deg or more an alert is outputted to Alarm emitted and freezes the actual rudder System while angle at this time turning This test is dangerous 11 Simulate failure in Emits alert and stops TCS function Remove power Autopilot Rudder angle is frozen at this time connection to autopilot while turning This test is dangerous 12 Simulate failure in Not influential Switches No 1 gyro automatically from No 1 to No 2 13 Check that second gyro Not influential is automatic applied in case of failure in the active gyro TECDIS Installation Manual Page 105 Checklists prior to completion of TECDIS TCS and TECDIS AW installation completed Vessel Name ID Date of installation Name of technician Checklist performed Sign The checklists in section 6 2 shall be filled in and signed for all TECDIS installations where Track Control functionality is present TECDIS TCS TECDIS AW in order to verify proper installation of the ECDIS system onboard 6 3 Additional checklist prior to completion of TECDIS AW installation 1 Conning Verify that when one of the ECDIS processors lose sensor data on one serial line display of sensor data relevant according to failed serial line on conning monitor is not affected enm Verify that installation is done according to block diagram for TECDIS AW system ii in Verify that installation is done according to func
75. efault values button is clicked a dialog window called Restore to xxxxx eToken Locate the setup file to restore from and click OPEN appears Locate the file that contains all the settings called T setup xxxxx tsz where xxxxx represents eToken serial number T setup xxxx tsz file is generated by TECDIS Setup every timer TECDIS Setup is started and stopped again The file is created by setting the Service Key into the computer stop TECDIS and start TECDIS Setup stop TECDIS Setup remove the Service Key T setup xxxx tsz file is saved to the Service Key automatically where represents the unit s eToken serial number Repeat for TECDIS No 2 T setup xxxx tsz file can be used by for an analysis of the setup installation and other settings Page 72 TECDIS Installation Manual 3 4 TECDIS NMEA and TCP IP server Comm port text Comm port text m Sf comem f cm Jf ewum s53 oma m por heating cowsm coma m cwweml 3 m cwvm z3 come m A comem 4 cm m 3 ewem s53 ecme Jf ecwwmm s53 coms mi eccomi Sf conii ecm m eco f f A cmwmm s53 Speed 34800 Data activity HEHDT 1935 T21 VDVHW 193 1 T 12 3M 0
76. el i Panel i QWERTY i Trackball 1 COM 3 MOXA HT 2 11 on MONA is ENIX 2067 only SE Mans DNH HP 6 DNH HPS 6 Mandatory z Position eVGA wee 220VAC RENI or 24 VDC pL 10 Optional Water Speed KEYBOARD ARPA PS 2 Radar Cursor TECDIS ant Computer unit Rel Wind OM3 5 2 TRACKBALL Route OMA AIS eee y OMS ot APB RMB RMC RTE Out COM2 Alarm Interface TEA 01 OM6 CONTROL OM7 term OMS UNIT 5 Furuno RCU 018 i Mandatory TCS OM10 2 i TECDIS Keypad i 2x position sensor OMII E R 2x heading sensor VDR i p i LAN RETTA 220 VAC 220 VAC SWITCH SWITCH EI NMEA GPS NMEA Gyro NP5500 NMEA Log Autopilot Interface 24 VDC Autopilot control NP5500 Operator Unit System failure Auto on 2 X Analog Rudder Order 10VY RUDDER FREEZE BOX Auto on SASS Syberg Autopilot Safety System Analog ROT from Gyro 10V system fail 24 VDC SASS Status Auto on Auto On AP Ready analog rudder order 10V Page 14 TECDIS Installation Manual Specifications Processor HT C01 TEL A596 D596 Compact high end industrial computer Microsoft Windows XP SP3 e Intel Core 2 Duo E8400 3 0 GHz Intel GMA 3100 integrated graphics processor 2GB RAM 8GB Max Toshiba 1 TB 2 5 Hard drive DVD C
77. en Jeppesen Marine support needs to make adjustments to the system By selecting a chart database and clicking Check Signature it is possible to verify that the database has not been corrupted and is in the same state as when provided by C Map 3 5 6 Monitor Calibration and Test This area provides information on the current monitor calibration status means to update the monitor calibration and diagnostics for testing the serial connection to the monitor Proper monitor calibration is needed to ensure correct chart colors and symbols To calibrate the monitor first attempt automatic calibration by pressing the Identify Monitor and Load Automatic Calibration button If this is not successful calibrate manually by pressing the Manual Calibration Load Calibration File button and selecting the correct calibration file Monitor Calibration and Test Monitor Calibration Status Calibration Name JH28T12MMDAATAAAA 00016 650 80 Monitor Type JH28T12MMDAATAAAA Identify Monitor and Load Automatic Calibration Manual Calibration Load Calibration File Monitor Connection Tests matching the monitor If such a file cannot be located this can be obtained from your TECDIS support provider Page 76 TECDIS Installation Manual Monitor Calibration Status Indicates the current status of monitor calibration The possible values seen here and steps to rectify any problems are as
78. en Marine invoices the vessel operator for the licensing costs This can either be done periodically or whenever the total outstanding amount exceeds the maximum invoicing amount defined in the subscription agreement 3 6 3 7 Benefits over traditional ENC chart licensing Dynamic Licensing provides a clear cost advantage over traditional ENC licensing e Traditional ENC licensing requires predicting which ENC charts will be required by the vessel Since ENC charts are only licensed when the vessel actually requires the chart with Dynamic Licensing no charts not needed by the vessel are licensed e Traditional ENC licensing typically provides 12 month licenses for ENC charts Since Dynamic Licensing generates 3 month licenses for ENC charts licensing costs for charts that are only required periodically or for shorter periods are lowered significantly Dynamic Licensing provides a clear operational advantage over traditional ENC licensing e There is no need to predict future ENC chart requirements for the vessel or to purchase chart licenses in advance e Activating new ENC licenses requires no chart licensing codes that need to be entered on the ECDIS systems e Usage reports are returned to Jeppesen Marine automatically during chart updating an operation that is performed routinely regardless of licensing method To summarize use of Dynamic Licensing ensures that ENC chart licensing costs are minimized and administration of cha
79. essages Chapter 4 Several minor fixes Revision 2 7 25 02 2014 Compass safe distance Equipment list Installation overview Specifications and Chapter 1 are expanded and updated to include o new computer ENIX 2077 new Audio Amplifier and rack kit for 2077 o new TECDIS Keypad and Logitech Trackman Marble trackball o new autopilot for TECDIS TCS NP5500 Chapter 1 New subchapters for outline dimensions of monitors and computers Chapter 1 8 amp 1 9 New subchapters for Autopilots NP5500 Chapter 2 1 2 3 New subchapters for computer specific wiring and signal distribution Chapter 2 6 1 2 6 3 New subchapters for computer specific I O connections Chapter 3 3 Specification is updated with video switch installation procedures Chapter 3 7 Added information for setup of new autopilots Chapter 6 Added monitor revision check and video switch ECDIS label check Chapter 6 Added checkpoint for NP5500 specific test of TCS Revision 2 8 08 01 2015 Change of specification HT C01 250 GB HDD replaced with 1 TB HDD Wiring diagrams corrected for TEA 01 Alarm interface connections Information for commissioning and sea trials for NP5500 Autopilot has been added o A wiring diagram for NP5500 with its SASS fall back safety system is inserted in the installation overview section 5500 TCS parameters have been added to chapter 3 TECDIS M F JULSUND Head Office Aalesund Furuno Norge AS Visitor address
80. ey dongle must be possible to remove and insert to enable service technician to enter service mode For the HD 24T21MEC integrated processor monitor a USB extension cable included should be used to allow this Do not protrude the housing with screws to fasten the processor Straps should be used to fasten the processor at its location without protruding the housing Straps are not supplied and must be arranged locally Check that front doors of processor can easily be opened and that cables can be easily arranged in the back of the processor 1 2 1 Special considerations for HT CO1TEL A596 D596 Leave sufficient space for the MOXA 8 PORT rs 232 422 connector cable The cables are 0 5m long The processor is suitable for 19 rack mounting with optional rack mounting kit Height is 4U 1 2 2 Special considerations for ENIX 2067 TEL D1 Leave sufficient space for the two MOXA 4 port RS 422 connector cables The cables are 0 5m long The processor is suitable for 19 rack mounting with optional rack kit enix 2000 series Height is 2U Outline dimensions for HD 24T21 MEC can be found on page 19 TECDIS Installation Manual FRONT VIEW 1 2 3 Outline dimensions for HT C01 TEL A596 D596 SIDE VIEW All figures in mm inches Page 34
81. fferential Pair 2 Negative Pin 06 RDN_ Receive Differential Pair Negative Pin 06 DIN _ Differential Pair 1 Negative Pin 07 NC Not Connected Pin 07 D3P__ Differential Pair 3 Positive Pin 08 NC Not Connected Pin 08 D3N Differential Pair 3 Negative Use category 5 twisted pair cable TECDIS Installation Manual Page 63 2 8 Other connectors Pin Assignments 9P Serial COM 5432 1 9876 Pin Assignments 15P HD RGB VGA 15 14 13 12 11 Pin 01 DCD Data Carry Detect Red analog Pin 02 SIN Serial In or Receive Data Green analog Pin 03 SOUT Serial Out or Transmit Data Blue analog Pin 04 Data Terminal Ready Reserved for monitor ID bit 2 grounded Pin 05 GND Ground Digital ground Pin 06 DSR Data Set Ready Analog ground red Pin 07 RTS Request To Send Analog ground green Pin 08 CTS Clear To Send Analog ground blue Pin 09 RI Ring Indicate 5V power supply for DDC optional Pin Assignments 5P PS 2 MOUSE Pin 6 Not Connected Pin 5 Mouse Clock Pin 4 Vcc 5V Jet Pin 3 Ground Pin 2 Not Connected Pin 1 Mouse Data Pin 2 Negative Data Pin 4 Ground Pin 1 VCC 5V Pin 3 Positive Data Digital ground Reserved for monitor ID bit 0 grounded DDC serial data
82. from TECDIS are set The table to the left information field shows the current settings and is instantly updated if changes are made by using the Input and Output folders at the upper right part of the window The pull down menu for Input selection will open close for other options to be selected as required to assist in making correct settings 3 2 1 The Input folder Note All position inputs to TECDIS from all external sensors must be in WGS 84 AN format TECDIS TELchart ECS Setup local Ip 172 318 711 192 168 0 103 Nmea Data Specification Chart Installation Misc Licensing Track Control TT output pata W mea input baud rPA into Y_N 4800 Position 1 GGA 6 51 Sentence and port select Position 1 M 10028 Radar 1 IP1 Radar cursor 1 IP1 eee eee Clear 0 0 0 0 pose 0 0 0 0 10028 Radar 2 38400 AIS IP3 172 31 3 71 2001 Sounder Radar cursor 2 IP1 Com9 Received data on selected port Monitor ctrl Alarm ctrl Control unit Trackcontrol Options 2 Options 3 Options 4 Com11 4800 Com3 4800 Comi 4800 Com2 19200 Wind Main display Alarm central Furuno keyboard Save to file TECDIS Installation Manual Page 65 Use this tab of the setup program to configure input signals by selecting the Data type either by activating the desired line in the table to the left or by selecting the Data type from
83. g on 60 deg course change 2 Repeat another side course change with same value Heading Control Starboard 10 deg turn with NAV FULL speed If available Good LING ON A Port 10 deg turn with NAV FULL speed If available Starboard 60 deg turn with NAV FULL speed Port 60 deg turn with NAV FULL speed Tests to be repeated with half speed ahead Testing of interference of radio transmissions while in heading control observe system while 1 Transmitting a call with FS 2570 2 Transmitting a call with VHF s 3 Transmitting a message with Felcom 15 1 amp 2 4 Transmitting a call with Felcom 70 Track Control Steering function test should be performed as follow in the next Steering lists Track Control Test and Fail to Safe Properties L1Good LING CIN A L1Good LING CIN A TECDIS Installation Manual Page 101 Track Control System Test Items to be checked during sea trial The following units have to be tested prior to the Track Control test ECDIS AUTOPILOT STEERING GEAR Create a test route for Track Control in keeping with the vessel maneuverability as per shown example attached or import by file Enter route menu check that icon 1 is monitoring activated primary route Use boathook to select route from previous test item Click yes when asked to activate route Check that route monitoring parameters are shown in right menu XTE next waypoint info etc Track Check t
84. hart utilities ENC Professional Alarm volume huxilar y Show help hints Ship draught Language selection Time zone selection Nmea input status Nav Position offset Chart utilities Alarm volume Auxiliary 0 Hide unhide tool tip Chart utilities Chart utilities Chart library Manual chart update C Map chart update Chart lisences INT 1 dictionary E Me ped Chart library installed chart databases Auvdlary hi Recalibrate screen Conning harbour mode Conning backward mode Export DB Status Ship draught minimum and maximum ship draught is defined in the setup program When TECDIS starts the maximum draught is used as default but this can changed in the setup menu folder TECDIS Installation Manual Page 87 4 11 1 Nmea data inputs Nmea data inputs Displaying a list describing which ports sensor port id describtion status the various sensor information is received Position 1 IP 1 GGA Gps 1 OK from Also displaying which Nmea Position 2 IP 1 GLL Ais OK sentences are used and the data COG SOG1 1 VIG Gps 1 OK communication status This is only an COG SOG 2 COM4 VIG Ais data information window Changes have to be Heading 1 1 HDT Gyro made in TECDIS Setup see chapter 3 Heading 2 COM 11 HOT Ais OK Speedlog P VHW Log OK 1 Radar 1 data
85. hat ship follows the test route selected keeping ECDIS Recommend test speed is normal NP5500 sea speed Observe the ship behavior through only several turns and either a increase the pivotpoint value between turns if the ship turns to late b decrease the pivotpoint value between turns if the ship turns to early No Track 1 Check that ship follows the test route selected on keeping ECDIS Recommend test speed is normal sea speed 2 Check performance according item 1 with speed reduction applied in one turn 3 Check performance according item 1 with inducing current effect by using bow thruster during turn Alarms 1 Set WP pre warning and WP approach time on the ECDIS as per drawing below Verify that WP approach Alarm is generated when the ship approaches the WP 2 Verify that separate Alarm system activates back up navigator alarm when WP pre warning and WP alarm on ECDIS is not acknowledged 3 Set alarm for gyro mismatch to minimum in TECDIS Setup program Wait for alarm to be raised 4 Activate route and use Heading Control mode on autopilot Steer outside channel limit to generate XTE alarm 5 Set Heading off alarm low and use bow thruster to provoke a heading drift Verify that alarm is raised 6 Set alarm difference limit for position and heading sensors and verify that no alarms are raised We recommend that the sum of 3xRMS route mean square is used Page 102 TECDIS Installation Manua
86. he Chart folder of the TECDIS menus Pressing this button activates Payment Mode C Base 210258 In Payment Mode all requested ENC charts are 2 ss wrt licensed disregarding the distance limit A clear warning is displayed on screen indicating that payment mode is active A route check can now be Dynamic Payment Active Alerts 0 2 show performed and all dangers cautions from the ENC charts will be displayed The route can also be adjusted manually using ENC charts Once the voyage plan check is complete Payment Mode is deactivated either by pressing the Payment button again or by removing the TECDIS Service Key Page 82 TECDIS Installation Manual 3 7 Track Control Nmea Data Specification Chart Installation Mise Licensing Track Control Autopilot Anschutz NP2025 Anschutz NPOoUD Emm SEMZOO FAP 2000 Simrad AP80 Starting requirements max course deviation Class AW max lane deviation 151 min speed min allowed turn radius x 0 01NM max allowed WOL distance x 0 01NM Default values new route 2 5 sposti Warning 1 Alarm 80 seo WP warning and alarm time lane x 0 01NM 1 Alarm limit difference primary and secondary heading turn radius x 0 1NM 12 Alarm limit difference primary and secondary position x 0 01 NM Use common heading and log sensors for TECDIS primary input and autopilot On this
87. higher Marine Equipment Directive Module B MED B IMO Resolution MSC 232 82 IMO Resolution MSC 191 79 IMO Resolution MSC 74 69 Annex 2 IMO Resolution A 694 17 Version 4 6 0 to 4 7 0 e Marine Equipment Directive Module B MED B e MO Resolution MSC 74 69 Annex 2 IMO Resolution A 817 19 as amended by MSC 64 67 Annex 5 and by MSC 86 70 Annex 4 e IMO Resolution A 694 17 For a current overview of software versions standards compliance and instructions for updating TECDIS software to comply with new standards and regulations refer to the following web site http www telko no site support tecdis compliance Equipment lists Standard Supply Computer AC HT C01 TEL A596 1 9 m power cable Keyboard Cherry G84 4100LCMGB 2 1 3 m PS 2 cable Trackball for HT C01 Mouse trak B MPIND XROHS 1 9 m PS 2 cable Trackball for HD 24721 Logitech TrackMan Marble 1 9 m USB cable TECDIS Installation Manual Page 11 Optional Supply Computer DC A HTCOTTELD596 1 Compuer DC END 267TELD Ji 711 JH 19T14 MMD EL ME LLL 1 9 m power cable 1 9 m power cable 1 9 m power cable 1 9 m power cable 1 9 m power cable 1 9 m power cable 1 9 m power cable 1 9 m power cable 1 9 m power cable Monitor ISIC DuraMon 26 WS 1 2 0 video cable also known as MD 26 05 1 9 m power cable 19 rack kit for computer 1 HT C01 TEL A596 D596 19 rack kit for computer Enix 2000 series Rack ki
88. i and EVE NMEA sentences There is also a tick box for activating on port 2000 in this folder TECDIS TELchart ECS Setup local Ip 192 168 0 235 i Nmea Data Specification Chart Installation Misc Licensing Track Control Input Output GGA 7 06 8061 VIG 4800 GPS1 8 C08 5082 VIG 5 4800 852 T Heading 1 6 4800 Gyro 12 6012 Heading 2 e Water speed 4800 Log COM 8 ow 10 Radararpai 0 0 0 0 10028 Radar 1 Iv Activate IP server port 2000 Radar arpa2 0 0 0 0 10028 Radar 2 Radar cursor1RSD 1 1 0000 10028 Radar 1 1 Serial port activity Radar cursor 2RSD 1 1 0000 10028 Radar 2 2 Gee AIS Alxxx 4800 AIS Depth DPT IPA 0000 2002 Sounder Received data on selected port Gear log Rel wind MWV IPA 0 0 0 0 2002 Wind Route RTE WPL RIE Monitor ctrl Hatte Ue Main display Alarm ctrl Digi e Alarm central Controlunit Reul e Furuno keyboard Trackcontrol 80 Le Simrad AP80 Navtex e Simulator Camera e Current Night Nav TECDIS Installation Manual Page 69 3 2 11 Supported NMEA Sentences TECDIS supports communication with external equipment using the following NMEA sentences as specified by the NMEA s
89. ight and calibration settings as well as the alarm sounder in the screen unit if used Ensure that the power supplied to the monitor is from the same source UPS mains socket etc as for the TECDIS Alarm ctrl Select the COM port that should be used for the alarm central interface if used In the NMEA sentence pull down menu there two choices Digi and ALR ALR will set the port up to serial NMEA communication with the alarm central Digi option should be used when connected to a proprietary alarm interface TEA 01 which is an open close relay contact Control unit RCU 018 Set Input port to COM 2 if the Furuno RCU 018 is connected to the TECDIS Physically the COM 2 port provides live 12VDC power to the Control unit and thus this port cannot be used to any other equipment Search Flir Select the COM port where gyro stabilized camera if used is connected Default setting is FLIR but that can be hanged to Curr for Current Page 68 TECDIS Installation Manual 3 2 10 The Output folder The Output folder in the upper right corner of the NMEA Data folder has settings for the following outputs e APB e RMB e RMC and e WPL RTE For each of the outputs there are choices of which of the physical COM ports the output should be directed trough The output folder is also where you configure the connection from TECDIS to VDR and BNWAS Note that for BNWAS you can select between Dig
90. ilitate maintenance 6 A magnetic compass will be affected if the monitor unit is placed too close to the magnetic compass Observe the compass safe distances to prevent deviation of a magnetic compass The distances are listed on page 3 7 An optional monitor bracket can be supplied for tabletop installations Screws for mounting the monitor to the console are supplied When bracket is used screws for attaching bracket and monitor together is supplied Screws for mounting bracket to table are not supplied The buzzer in monitor HD19T03 is only approved for ECDIS alarm sound when the monitor is not flush mounted The monitors ISIC DuraMon 19LED and DuraMon26 WS both require use of either e Audio Amplifier card and external speaker Furuno RCU 018 control unit e TEA 01 Telchart Alarm interface for ECDIS alarm sound Special conditions for HD 24T21 MEC processor with integrated monitor Attach a USB extension cable included to a USB port for service key external CD DVD reader to allow easy access TECDIS Installation Manual Page 21 1 1 2 Outline dimensions for Hatteland Display processors with integrated monitor Outline dimensions for HD 24T21 MEC FRONT VIEW SIDE VIEW R350 0 4 je 593 00 23 35 4 7640 3 01 Maxheight i 38400 11512 36790 1448 31842 12 54 8 05 0 32 40 58 1 60 800 0 31 25 00 098 BOTTOM VIEW DIMETRIC VIEW 45 00 1 77 TOP VIEW 576 90 22 71 490 0
91. inch viewable image size MVA Multi domain Vertical Alignment Active matrix LED LCD Pixel number 1920x1080 Full HD Pixel pitch RGB 0 276 mm H V Response time 25 ms Contrast ratio 3000 1 Light density 300 cd m2 Auto detects VGA to FHD Full HD Viewable angle 89 deg H V L R Active display area 531 36x298 89 mm H V Multi power supply 115 VAC 50 Hz and 230 VAC 60 Hz 24 VDC 125 W max Weight 11 2 kg Dim 593 W x 384 H x 76 40 D mm TECDIS Keypad 20 short travel switches 19 indicator lights Key switch lifetime 200 000 operations IP22 Protection level Connection USB Auto dimmable key backlight Light sensor for key backlight dimming Operation temperature 15 C 55 C Size 124 W x 196 mm Cutout size 114 W x 186 H mm 4 The Furuno connector is exclusive to the HT C01 processor units The USB 1 1 port is locked at 12Mbps and should only be used for the eToken TECDIS Installation Manual Page 15 Monitor JH 19T14 MMD 19 0 inch viewable image size Active matrix Thin Film Transistor Pixel number 1280 x 1024 Pixel pitch RGB 0 294 mm H V Response time 12 ms Contrast ratio 900 1 Light intensity 300 cd m2 Viewable angle 85 deg H V L R Display area 376 32x301 056 mm H V Auto detects VGA to SXGA Optimum picture with 60 Hz Input signal DVI D DVI D input 24pin Input signal RGB 15pin HD D sub Input signal Multifunction
92. inputs are valid Check L1Good LING ON A 1 External data input values for position and course TECDIS 2 L1Good LING CIN A Verify that TECDIS receives valid sensor data from a minimum TECDIS 1 of 2 External data e Two independent positioning sensors c T N A e Two independent heading sensors i TECDIS 1 3 Alarm system erify that TECDIS is connected to a separate alarm system 3 NA L1Good LING CIN A TECDIS 1 4 System status Check that no alarms warnings are pending in alarm window E N A L1Good LING L1N A 1 Select setup menu chart utilities chart licenses TECDIS 1 2 Verify that licenses are valid for intended voyage 5 Chart database 3 Click C Map chart update oa A Verify that charts are updated in update log L1Good LING CIN A Sea Trial Test 15 minutes 1 Activate ARPA on radar and select a target TECDIS 1 6 b cas 2 Click the symbol button of ARPA Targets L1Good LING ON A If 3 Click the symbol button of AIS Targets TECDIS 2 P AIS and ARPA Targets are displayed on the top of charts L1Good ONG ON A Correct indication is shown at the each configured wind acne orrect indication is shown at the each configured window Conning display L1Good LING ON A 7 If present ithe Conning Display Verify that selected sensors used by TECDIS 2 heading position is correctly indicated L1Good LING CIN A Route Monitoring Before start TEST routes must be created or transferred from other TECDI
93. is checkbox is marked it is assumed that bearings lines received from the radar s are true referenced If this option is not marked TECDIS will perform the necessary adjustments is conning referenced When this checkbox is marked it is assumed that target information from Arpa radar is already adjusted to the navigator position If it is not marked TECDIS will perform the necessary adjustments In the Monitor field the following should be set o Monitor inch diagonal Specify the diagonal size of the monitor here This information can be found on page 12 to 15 TECDIS Installation Manual Page 71 o Backward gyro 180 Checking this box turns the heading value from gyro 180 degrees In the Main menu field you can select how you want to display the main menu either horizontally along the top of the monitor or vertically on the left side e With video toggle activated you can select the monitor input used for the video feed With this activated the user can toggle between viewing the feed from the ECDIS Unit or the external video feed on the ECDIS monitor NOTE If the TECDIS unit is set up with a video feed the monitor has to be labeled with an ECDIS label on the front of the bezel for the installation to AN comply with the type approvals If the TECDIS monitor is of the xxT1x ie 19T14 generation the alternative display communication box must be ticked e Inthe A
94. is conning referenced Monitor size main menu 24 21 sidebar 9 16 backward gyro 180 Iv Video toggle VGA z Alternative display comm Alarm lv Allow Standby Mode T Afanmif HUTI HUTZS zd Remote silence only Allow route activation entry lane Erase Secondary past track Name SKS DEMINI Restore saved default values MMSI 259985000 In the Ship Size field enter the length beam draught and height of the vessel in meters For Length and Beam fields the ship s largest dimension value for length and beam should be used For Draught and Height the largest possible height and draught taking load conditions into consideration should be entered When a second and third TECDIS unit is present in the installation for example dual installation and backup unit The IP address of the second and third TECDIS unit should be entered in the Other TECDIS field This will activate automatic transfer of active routes to the second TECDIS and it will be possible to transfer data objects tracks routes to the second and third unit unit this value should be cleared For any other value in this field TECDIS will NOTE If the TECDIS unit is not to be connected to a second or third TECDIS generate an alarm if unable to connect to the other TECDIS unit e Radar use true EBL reference When th
95. isconnect position Same as above Remove No 1 2 sensor on a straight leg position sensor 3 Disconnect position Alert will be emitted only from ECDIS Remove No 1 sensor during max radius which places no influence on TCS position sensor turn function output connector during maximum radius turn 4 Turn Heading Control Not available Adjustment of System rudder limit to min value during min radius turn rudder limit is not available 5 Disconnect serial Emits alert and stops TCS function Remove Track link to heading simultaneously It automatically Control connection controller during switches to heading mode from ECDIS while straight leg sailing straight ahead 6 Disconnect serial Emits alert and stops TCS function Remove Track link to heading simultaneously Automatically switches Control connection controller during to heading mode after turning to the pre from ECDIS while turn determined maximum degree sailing straight ahead 7 Disconnect speed log Although it emits an alert input of two Remove LOG input during straight leg position sensor data maintains the outputted to ECDIS or turn normal function while turning 8 Simulate failure in Same as item 5 or 6 Turn off ECDIS ECDIS 9 Simulate failure in Not influential Turn off Conning conning display Display 10 Disconnect rudder Emits an alert If the deviation between Remove rudder feedback order rudder angle and actual rudder fe
96. isplay area 396 75x317 25 mm H V Auto detects VGA to SXGA Optimum picture with 60 Hz Input signal DVI I 29pin Input signal RGB DVI A DVI connector Input signal S Video Control input output RS 232 D sub 9pin Power 90 265 VAC rms 50 60 Hz 5 Hz 55 W typical Weight 10 kg approx HW revision number is part of model number Monitor HD 26T21 MMD 25 54 inch widescreen viewable image size Active matrix S MVA Thin Film Transistor CCFL backlight Pixel number 1920 x 1200 Pixel pitch RGB 0 2865 mm H V Response time 8 ms Contrast ratio 1500 1 Light intensity 350 cd m2 Viewable angle 88 deg H V L R Display area 550 08x343 8 mm H V Auto detects VGA to WUXGA Optimum picture with 60 Hz Input signal 2x DVI D 24pin Input signal 2x RGB 15pin HD D sub Input signal 3x Comp video BNC connector Control input output RS 232 D sub 9pin Multi power supply 115 amp 230 VAC 50 60 Hz 24 VDC 107 W typical Weight 14 8 kg HW revision number is part of model number Monitor Furuno MU 231CE 23 1 inch viewable image size Active matrix Thin Film Transistor Pixel number 1600 x 1200 Pixel pitch RGB 0 294 mm H V Contrast ratio 500 1 Light intensity 250 cd m2 Viewable angle 80 deg H V L R Display area 470 4x352 8 mm H V Auto detects VGA to SXGA Optimum picture with 60 Hz Input signal DVI I 29pin Input signal RGB DVI A DVI connector Input signal S Video Control i
97. istance from Waypoint New command to track Wheelover 0 05 NM F pilot and route monitoring Please verify these values with the vessel s Master before finalizing the installation These parameters are not part of the setup program but are included in the normal program Page 88 TECDIS Installation Manual 4 3 Operational parameters for AIS 4 31 Display filter Range and Track AIS targets outside specified range are filtered from display Track specifies length of AIS target tracks in minutes Setup Chart Ship Data Log Safe Ais e 4 3 2 Display filter All t ts acti onm sd isplay filter argets active Range 50 NM Allows all AIS targets to be shown with heading COG vectors and Track 12min 7 tracks In INTI chart display mode target names are displayed pieke al 4 3 3 Display filter Hide class B Ide class Allows filtering display of class B AIS targets Relative COG vectors Ja 2 lostactivetargets 4 3 4 Display filter Relative COG vectors Distlimit Olof Allows display of COG vectors relative to own ship movement Vectors are true if this option is not selected Alarm when lost Danger CPA all targets 4 3 5 Lost active targets time distance AIS targets inside the specified range will be indicated with a black X 2 min over the target when it is lost If Alarm when lost is activated an 5 alarm will be raised Raise CPA alarm Show danger 4 3 6 Danger CPA all
98. istration of La d Mycinogranhio Service Royal Netherlands Navy Error L60147 T1565 open border of Indare 3229 84 8678 80767 48 25 E M l Error 60147 T1565 open border of Indare 32 29 34 94 S 607574887 Find Import 557 Remove Dataset Error 1501471 T1565 open border of Indare 82 28 85 42 6057 0 01 E If errors are discovered a 57 Import ERROR report is shown The error report contains name of import file and whether the error are critical or non critical Files including critical errors are not imported If non critical errors occurs files can be imported or excluded by pressing continue or skip If stop is pressed the import process is terminated Disable error report If this option is selected prior to data import the process will run automatically S57 import files including critical errors will be excluded and files with non critical errors are imported NB When using disable error report it is impossible to view detailed information about the data import Also errors reasoning ENC cells not to be imported due to critical errors are not displayed Chart Catalogue Hellenic Navy Hydrographic Service Hydrographio and Oceanographic Department Japan amp Hydrooraphio Servioe Maritime Administration of La Hydrographio Servioe Royal Netherlands Navy wy Find Import 557__ Remove Dataset An import log will be created This log can b
99. ity on selected monitored comport HDT is marked in blue due to it is selected for output to TCP IP Clients Shows how many listeners connections there are on each connected TCP IP port TECDIS Installation Manual Page 73 3 5 Chart Installation Misc Nmea Data Specificatil in Chart Installation Misc LBensing Monitor Calibration and Test Enter Registration Information Monitor Calibration Status Vessel Name and Installed By is mandatory information is required for chart subscriptio z gt PN Nmea Data Specification Chart installation Misc Licensing Vessel Name Regina Ill Monitor Galibration and Test Installed By Ove Br then Status Monitor Calibration Status Chart Database installation has been completed and user IMO 1284567 registration has been sent to Telko TECDIS is now ready for use si a Calibration Name JH19T02MMD for Matrox P650 Callsign i B Z Copy Chart Database to Harddisk ee essel Type Supply Install a new Database remove a Database Identify Monitor and Load Automatic Calibration owner Telko AS or update an existing base with a new CD ERE Address Bdekjeerveien 27 Tjome Norway Enter Vessel Information rao ee i Enter information about the vessel required _Enter Yard build for warranty and chart licensing Conning ver Monitor Connection Tests Send Registration Notes Generate registr
100. l Example of route for Track Control testing ill 1 IL WPT 3 135 deg turn port WPT 5 135 deg turn starboard both with minimum radius WPT 4 60 deg turn port WPT 7 60 deg turn starboard both with 2 NM radius Minimum radius to be settled after calculations from yard TECDIS Installation Manual Page 103 ECDIS Scheduled Track Course 90 deg AP Scheduled Course 90 deg Wheel Over Point WP Approach alarm 30 sec before wop Pre Warning alarm 120sec before 7 4 Trial Speed NSR a a Approach run TCS Test 2 Failure point TCS Test3 at straight leg Failure point in turn Ship start turn from wheel over point with 90 deg Angle Turn radius is with 1 0NM Page 104 TECDIS Installation Manual Fail to Safe Properties Item Fail Track Control TCS Test Result 1 Position sensor antennas When either of position sensor Remove No 1 to be blinded off acquisition stops TCS emits alert but position sensor continues to function utilizing acquired antenna position from other position sensor LOG and GYRO When both position Remove No 2 sensor acquisition stops TCS emits alert position sensor but begins navigation utilizing estimated antenna position made available by LOG and GYRO Then it within 10min automatically switches to heading mode and manual maneuver will be in effect 2 D
101. land 26T2 MMD Furuno MU 201CE Furuno MU 231CE ISIC DuraMon 19LED ISIC DuraMon 26 WS Hatteland i CONNING i MONITOR SOURCE i r ssssusse uuuuuuune z z SETUP 1 PRIMARY TECDIS 220 VAC or 24 VDC Hatteland HT C01 TEL A596 Hatteland HT C01 TEL D596 ENIX 2077 TEL DI MOXA Opt SF or 2x4F LAN LAN 220 VAC SWITCH 4x Phoenix ID NViproseneni connector SETUP 2 SECONDARY TECDIS Hatteland HD 24T21 integrated monitor 220 VAC 24 VDC Alarm Interface 01 iSWITCH 220 VAC Keytouch Panel Combo coneneenane i Keytouch Keytouch Panel Panel QWERTY Trackball 504 SPEAKER 5 DNH HP 6 seo I DNH HPS 6 H H usssssssson KEYBOARD S 2 Cherry G84 4100 TRACKBALL Mouse Trak COM2 CONTROL UNIT Furuno RCU 018 O 220 VAC VSAT Internet me DVD reader USB i KEYBOARD WSR Cherry G84 4100 iS TRACKBALL Logitech Trackman Marble i SPEAKER s o5 DNH HP 6 a DNH HPS 6 PRA RR EN T Keytouch i Keytouch H H Panel Panel i QWERTY lrackball i 2 TECDIS Installation Manual Page 13 TECDIS Track control system with NP5500 220 VAC Keytouch Panel Combo 220 VAC pees i ECDIS MONITOR CONNING DO ANE 2 i MONITOR eytouch i eytouch i Pan
102. larm field you can select o Allow Standby Mode When this option is activated it will be possible to set TECDIS in Standby Mode In this mode no audible alarms will be generated Activating this option also allows CPA alarms to be disabled in TECDIS NOTE A prominent warning is displayed whenever the Standby Mode is active o Alarm if HDTI HDT2 gt 2 5 When this box is checked an alarm will be given if the heading from the two sensors Heading 1 and Heading 2 deviates with more than 2 5 degrees Note If the TECDIS system has the option Track Control enabled this box is inactivated as control for this alarm is set up in the Track Control folder o When selecting the Remote silence only checkbox an acknowledgement made on an TECDIS alarm in an Alarm Central not part of TECDIS system only turns off the audible alarm signal The TECDIS alarm situation must be solved in TECDIS e If two positioning methods are in use the button Erase Secondary past track allows you to remove the past track line from the secondary position sensor e NAME The vessel name should be specified in this field e The MMSI number should be specified in this field e Restore saved default values button allows you to retrieve all settings made in the NMEA Server Conning and TECDIS setup from the backup file that was saved in the Service key last time TECDIS Setup was closed When Restore saved d
103. lp you they will need your System ID number Before contacting anyone at least some of the tests here should be attempted Tests applicable to only weather overlay features are marked Weather Tests applicable to only chart updates are marked Updates GENERAL TESTS A Check your subscription Make sure that your subscription has not expired Weather Overlay Expiry information can be seen by opening the weather overlay pressing Data Download New and then Show Subscription B Weather Update your subscription Jeppesen Marine may make changes to the weather service that are not automatically reflected by in your subscription C Try another connection method If you use an internet connection try downloading by email If you use email already try using another email account system If this is successful you have verified that the problem is with your connection not your chart system or a problem with the update weather service D Weather Try a smaller download size The problem may be connected to downloading large files especially if the connection is noisy and or error prone E Weather Try another model The problem may be connected to downloading a specific forecast method If a download of similar size using a different model is successful the list of potential causes for the problem is significantly reduced F Try updating the chart software Telko AS provides software updates containing
104. lue Verify mode Heading Control of heading change radius or R O T mode by observing key Good LING LIN A lamp 3 Alter set course by either turn knob and push set button to acknowledge or push and turn knob Observe correct rudder response 4 Observe rudder movement 5 Observe that max rudder limit is not exceeded 1 Rudder moves to 10 degrees PORT when SET HEADING is Steering Control set by 20 degrees below Gyro heading L1Good LING ON A 2 Confirm the actual rudder angle by rudder angle indicator 1 Change operating mode from hand to heading control at Track Control TECDIS verify that correct mode is indicated on TECDIS and conning monitor also Shift from heading control to manual mode by switching steering mode selector Verify that change to manual mode is possible from all modes with a single operator action Change set course 50 deg to starboard off heading alarm not to be activated during setting of new course Alarm is de activated for a time period that is a function of present course and new desired course Test override tiller in modes hand heading control and track control Autopilot to go to hand External data L1Good LING CIN A Function L1Good LING L1N A Function L1Good LING CIN A Function L1Good LING CIN A Sea trial test 240 minutes Response and stability of Heading Control steering 1 Observed overshooting should max 2 deg on 10 deg course change and max 5 de
105. n Connection to TECDIS The serial transfer module NB05 343 on the Anschiitz NP 2025 PLUS must be connected to a TECDIS serial port and configured in TECDIS SETUP See chapter 3 7 Page 48 TECDIS Installation Manual 1 7 Track Control Furuno FAP 2000 and EMRI SEM 200 Autopilot Refer to Furuno 2000 Autopilot Instruction Manual 8395 2 or EMRI SEM 200 Autopilot Instruction Manual 8380 2 for installation of the autopilot All applicable procedures and guidelines are to be followed For valid installation and operation of Track Control functionality TECDIS must be as a minimum be connected to the following Two Independent position sensors Two Independent heading sensors Speed sensor Alarm System for transfer of back up navigator alarm TECDIS and the Furuno FAP 2000 Autopilot or EMRI SEM 200 Autopilot must be supplied with the same set of heading and log sensor inputs e Alarm System for transfer of back up navigator alarm Both TECDIS and the Furuno FAP 2000 Autopilot or EMRI SEM 200 must be configured with the same LOW SPEED LIMIT value On vessels where the steering system does not provide a freeze rudder function and maintained voltage is required for maintaining rudder angle provisions must be made on installation of Furuno FAP 2000 Autopilot and or EMRI SEM 200 Autopilot to maintain steering voltage output on power loss to the Furuno FAP 2000 Autopilot or EMRI SEM 200 Autopilot gt gt
106. ng and signal distribution On the following pages wiring and signal distribution diagrams are shown Signal distribution diagram is an indication of possible means of signal distribution During installation actual need for signal distribution must be verified by installer depending on signals available and actual hardware installation on the specific vessel 2 1 Serial connections for HT C01 TEL A596 D596 Most sensors will be connected using the RS 232 RS 422 Serial Split cable with 8xDB9 connectors attached to the computer s Moxa Connector This cable provides COM ports 3 to 10 labeled on the connectors as 1 to 8 The pin assignments for these connectors as follows Moxa serial split cable DB9 male pin assignments Pin No RS 422 RS 232 1 TxD A DCD 2 TxD B RxD 1 5 3 RxD B TxD 4 RxD A DTR 6 DSR 7 RTS 6 9 8 CTS 9 RI Each serial port from COM 3 to COM 10 is optoisolated and can be individually configured to RS 232 or RS 422 Per default COM 3 will be set to RS 232 and COM 4 to 10 will be set to RS 422 The serial ports can be reconfigured by opening the computer and setting DIP switches on the Moxa serial port PCI card as specified below DIP switches on Moxa CP118U I default configuration shown Mode S1 52 S3 RS 232 ON RS 422 ON OFF 4 wire RS 485 ON OFF OFF 2 wire RS 485 OFF OFF OFF Jumpers JP1 to JP8 activate onboard termination resistors for each se
107. nger mandatory Equipment list Installation overview specifications and Chapter 1 Mounting sections expanded and updated to include new computer HT C01 TEL A599 new display HD 19T03 and new flush mount keyboard trackball options from Keytouch e Chapter 2 Wiring and signal distribution updated with instructions for new computer HT C01 TEL A599 e Section 3 6 3 Dynamic Licensing expanded with information previously only found in separate documentation e New section 5 3 Internet VSAT connection troubleshooting added New section 2 4 Other notes regarding connectors and wiring added Revision 2 3 28 10 2010 e Compass safe distances for new equipment added to page 1 e General introduction to the installation manual updated with reference to important installation instructions in Chapter and Chapter 2 e Equipment list Installation overview specifications and Chapter 1 Mounting sections expanded and updated to include new computers HT 01 TEL A596 and HT 01 TEL D596 new displays JH 23T14 MMD Furuno MU 201CE and Furuno MU 231CE and new keyboard Cherry G84 4100 e Chapter 2 Wiring and signal distribution updated with instructions for new computers HT C01 TEL A596 and HT 01 TEL D596 e Section 3 2 NMEA Data updated with information on Ex input ALR ACK FLIR control Revision 2 4 18 05 2012 New chapter 1 7 Track Control Furuno 2000 and EMRI SEM 200 Autopilot
108. nput output RS 232 D sub 9pin Power 90 265 VAC rms 50 60 Hz 5 Hz 60 W typical Weight 15 kg approx HW revision number is part of model number TECDIS Installation Manual Page 17 Monitor ISIC DuraMon 19LED 19 0 inch viewable image size LED LCD Thin Film Transistor Pixel number 1280 x 1024 Pixel pitch RGB 0 294 mm H V Response time 20 ms Contrast ratio 2000 1 Light intensity 300 cd m2 Viewable angle 80 89 deg L R T B Display area 376x301 mm H V Auto detects VGA to WUXGA Input signal DVI 24pin Input signal RGB 15 HD D SUB Control input output RS 232 D sub 9pin Power 90 264 VAC 50 60 Hz 40 W typical Weight 6 5 kg HW revision number Part no 05519 xxx Keytouch Panel Combo Flush mount QWERTY keyboard and trackball 85 3 short travel switches Polyester with key embossing Key switch lifetime 200 000 operations IP22 protection level Connection USB type B Dimmable backlight Light sensor for backlight and LED dimming Dim 413 W x 196 H mm Cutout 363 W x 177 H mm Keytouch Panel Trackball Flush mount trackball Ball diameter 50mm Ball reading Laser 3 short travel switches Polyester with key embossing Key switch lifetime 200 000 operations IP22 67 protection level Connection USB Dim 124 W x 196 mm Cutout 104 W x 176 H mm Monitor ISIC MD 26KM05 DuraMon WS 26 0 inch widescreen viewable image size Thin Film Transistor LC
109. pter 2 6 3 on page 61 2 6 1 HT C01 TEL A596 D596 rf acean o LOUDSPEAKER e NB Only connect Furuno RCU 018 to RCU 018 connector Proprietary connector supplies live 12V DC current and may damage any other equipment connected gt 001 Ooo000g o gcoopaconnonnrnorna UD TRACKBALL e is to be used for TEA 01 Alarm central interface ECDIS monitor control may be connected to COM 1 directly Other sensors may be connected to COM1 via an RS232 RS422 interface such as AD400 e Connect ECDIS monitor using the DVI I connector If optional speaker connectors HT00072 Opt A1 are used LINE OUT and LINE IN are to be connected using the supplied cable e LAN connector LAN
110. r by IP Setup Replication activated on both TECDIS 1 Make backup copy of all important routes 2 See to that the route library is updated on ONE TECDIS 3 Delete all routes on the OTHER TECDIS using this application A Then activate replication on TECDIS with updated route library All new routes and changes made on existing routes are automatically copied to the other ECDIS Current status this TES elete ALL routes on this TECDIS and activate replication Retain routes on this TECDIS and activate replication Execute TECDIS Installation Manual Page 85 Activating Replication Follow these steps to activate Replication 1 Verify that the requirements for this feature listed above are met 2 If routes are present on the TECDIS units select one unit where all routes will be kept and one TECDIS unit where all routes will be removed On both TECDIS units insert the Service Key and exit to Windows On both TECDIS units run C Program Files TECDIS Replication exe On the TECDIS unit where all routes should be kept select Retain routes on this TECDIS and activate replication and press Execute 6 On the TECDIS unit where all routes should be removed select Delete ALL routes on this TECDIS and activate replication and press Execute 7 On both TECDIS units remove the service dongle and reboot the system D After both TECDIS units are again operational all routes from the unit wher
111. rial port individually These jumpers should not be activated on a normal installation TECDIS Installation Manual Page 53 2 2 Serial connections for HD 24T21 Most sensors will be connected using the Spin Phoenix signal ports COM 3 6 The pin assignments for the Phoenix ports are as follows B E 01 TxD Transmit Data Negative PIN 02 TxD Transmit Data Positive RS422 03 GND Isolated Ground 4 Ports Virtual COM identified the Operating System OS Receive Data Negative COMx A COMx B COMx C COMx D PIN 06 TxD _ Transmit Data Negative Configuration dependent x next available port number s OS PIN 07 TxD Transmit Data Positive PIN 08 GND Isolated Ground PIN 09 RxD Receive Data Negative PIN 10 RxD Receive Data Positive RS 485 Half Duplex 2 wire supports ECHO Configuration Connect TX and RX pair wise TX to RX TX to RX COM 1 is configured to RS 232 COM 2 is configured to RS 422 and COM 3 6 are by default configured as RS 422 COM 3 6 are optoisolated The ports are attached to the motherboard using standard USB interface and will therefore appear as virtual COM ports when identified by the OS RS 232 reconfiguration is not possible for COM 3 6 COM 7 is a virtual serial connection to the monitor 2 3 Serial connections for ENIX 2077 TEL D1 Most
112. rm interface TEA 01 Length 125 mm Width 55 mm Heigth 40 mm Cable length 1400 mm Cutout hele 99 mim Page 46 TECDIS Installation Manual 1 1 1 Outline dimensions for loudspeaker DNH HP6 with bracket mount 85 mm 997 mm Loudspeaker cable length is 500 mm 1 1 2 Outline dimensions for loudspeaker DNH HPS6 for flush mount 121 mm TECDIS Installation Manual Page 47 1 6 Track Control Anschiitz NP 2025 PLUS Refer to Anschiitz NP 2025 PLUS installation manual for installation of the autopilot applicable procedures and guidelines are to be followed AN For valid installation and operation of Track Control functionality TECDIS must be as a minimum be connected to the following e Two Independent position sensors e Two Independent heading sensors e Speed sensor e Alarm System for transfer of back up navigator alarm A TECDIS and the NP 2025 PLUS must be supplied with the same set of heading and log sensor inputs On vessels where the steering system does not provide a freeze rudder function and maintained voltage is required for maintaining rudder angle provisions must be made on installation of Anschiitz NP 2025 PLUS to maintain steering voltage output on power loss to the NP 2025 PLUS Location of change over controls The steering mode selector switch or override facility if installed shall be located at or in the immediate vicinity of the main conning positio
113. rt licenses is handled automatically by the system reducing the workload both for bridge personnel and for vessel operators 3 6 4 Using Dynamic Licensing in TECDIS After a dynamic licensing agreement is made between Jeppesen Marine and the vessel operators this feature is automatically activated in TECDIS the next time the C MAP Update Service Online is used After activation ENC charts will automatically be licensed for all required charts within a specified distance of the vessel This ensures that ENC coverage is always available for the vessel location and that early route planning or spurious chart requests does not result in ENC licensing costs The current state of the dynamic licensing licenses are dynamic agreement credit limit last usage report and 1 dynamic licenses Dynamic Licensing Range 5 next reporting deadline can be monitored by Chart DE accessing the chart licenses interface in TECDIS and clicking on the dynamic license entry in the list TECDIS Operators Guide chapter 3 2 By default all ENC charts requested within 5 nautical miles of the vessel are automatically licensed TECDIS Installation Manual Page 81 When the credit limit is lower than 200 credits or the next reporting deadline is within 3 days this is reported to the operator as warnings in the alarm system When the credit limit is exhausted or the reporting deadline has been exceeded this i
114. ry full or error Try restarting ECDIS 11 Bad init parameters System error should not normally occur 12 Data files not found Old data file has been erased or destroyed New empty data file is automatically generated 13 Open db cannot determine type of file Installation error use of invalid data 14 Data files appear to be corrupted Try restarting ECDIS to generate new data file rr A A eee 111 g_map gt SetRotation failed System error should not normally occur i a ul 191 File number out of bounds Error in license dongle TECDIS Installation Manual Page 93 197 No eToken dongle present No license dongle found 198 Cmap init error Error in license dongle 199 Init has not been called Error in communication with license dongle 200 Unknown error Important With errors relating to license dongle try removing then reinserting the license dongle or try moving it to another USB port Then try restarting the ECDIS 5 2 Monitor Calibration All information in electronic chart displays must be highly visible To ensure this monitor must be calibrated to display correct colors This is very important especially for night palettes when monitor is dimmed ECDIS color test for monitor calibration is also placed in presentation library Open library by pressing Control alt shift and select test diagram by pressing A C D E or T on the keyboard Brightness check Open test diagram E and
115. s reported to the operator as alarms in the alarm system TECDIS Operators Guide chapter 5 5 Lists of dynamically licensed ENC charts both reported and unreported can be viewed in the C Map Chart Manager available in the Chart Installation Misc folder in the TECDIS Setup program TECDIS Operators Guide chapter 7 4 3 6 4 1 Adjusting the distance limit for automatic ENC licensing To adjust the distance limit for automatic ENC licensing the TECDIS Service key is needed When the TECDIS Service key is inserted it is possible to adjust the distance limit in the chart licenses interface in TECDIS See illustration on previous 3 6 4 2 Route Planning using ENC charts Since only charts within a specified distance are licensed automatically standard mode it is possible 2 Log Safe Ais to plan a potential voyage in advance without SE Setup Chart ship Data incurring additional ENC chart licensing costs Once Layers Payment it is decided that the voyage will take place the 2 Taxt 2 Iv voyage plan should be checked using ENC charts in 82 eae order to comply with official requirements for T iue ra Shallow sounding Gal Deep soundings paperless navigation All depth contours The TECDIS Service Key is needed to license charts outside the specified distance limit When the TECDIS Service Key is inserted a Payment button will be available in t
116. ses 857 1 2 CHART SUPPLEMENTARY INFORM ChartletsBase 1 _ E Read Chart Database CD Select the CD ROM drive Found World 193 This Database is a newer edition of an installed DB Start Alternatives Update Update existing Database with new CD Remove Delete this Database from the harddrive Page 74 TECDIS Installation Manual Copy Chart Database to Harddisk Insert the chart CD and follow the instructions that appear Select a Database Select an installed chart database Ci CHART SUPPLEMENTARY INFORMATION 1 Selected 5871011 This Database has already been installed Alternatives Remove Delete this Database from the harddrive Set as Default Set this Database as default If a CD DVD is not available for the chart database As would be the case for databases containing imported S57 data these databases can be selected for modification by choosing a drive other than the CD DVD drive from the drive drop down menu For example D When Setup is unable to find a chart database on the selected drive you get the option to manually select an installed database by pressing the button Select an Installed DB You will get two options for the database you select from the list of installed databases Remove Set as Default We recommend that the World database should be set as default if installed Important Some chart databases are pro
117. t 1 Bracket for monitor Several options are available 1 Audio amplifier PCI card HT 00072 OPT A1 for HT C01 TEL A596 D596 Audio Amplifier PCI Lyd UK153 For ENIX 1 4 m cable 1 1 Extra 4x Moxa connector CP 114EL I CV 150k 1 Speaker bracket mount DNH HP 6 1 05m cable Control Unit j FurnoRCU 018 1 1 1 Trackball Logitech TrackMan Marble 1 9m USB cable Loudspeaker required when display unit or control unit does not contain a buzzer Loudspeaker required when display unit or control unit does not contain a buzzer Furuno RCU 018 is only available for the HT C01 Processor units Page 12 TECDIS Installation Manual General Mandatory Position Heading COG SOG Track Control Mandatory Raytheon Anschiitz NP2025 PLUS Optional Water Speer ARPA Radar Cursor Depth Rel Wine Route AIS APB RMB RMC RTE Alarm Interface 0 I COM 3 on COM 11 MONA is HT CO on MONA is ENIX Mandatory Position Heading COG SOG Track Control Mandatory Raytheon Ansch tz NP2025 PLUS Optional Water Speed ARPA Radar Cursor Depth Rel Wind Route AIS APB RMB RMC RTE Out 220 VAC VIDEO FEED Installation Overview ECDIS MONITOR 20T17 MMD Hatteland 19T 14 MMD Hatteland JH 23T 12 MMD Hatteland HD 19T03 Hatteland HD 19T21 MMD a nd HD 24121 MMD Hatte
118. tandard and IEC 61162 1 Ed 3 0 NMEA Description Send Receive sentence ABK AIS AIS addressed and binary broadcast acknowledgment Receive ABM AIS AIS Addressed Binary and Safety Related Message Send ACK Acknowledge Alarm Send Receive ACN Acknowledge Alarm Send Receive ALC Alarm control Send ALF Details of a new alert Send ALR Set Alarm State Send Receive APB Heading Track Controller Autopilot Sentence B Send ARC Alert command not accepted Send BBM AIS AIS Broadcast binary message Send DBT Depth Below Transducer Receive DPT Depth Receive DTM Datum reference Receive VE Optional interface to reset dormant period of the BNWAS Send GGA Global Positioning System GPS Fix Data Receive GLL Geographic Position Latitude Longitude Receive GNS GNSS Fix Data Receive HBT Heartbeat for BAM Send Receive HDT Heading True Receive MTW Water temperature Receive WV Wind Speed and Angle Receive OSD Own Ship Data Receive MB Recommended Minimum Navigation Information Send MC Recommended Minimum Specific GNSS Data Send Receive OT Rate of Turn Receive RSA Rudder Sensor Angle Receive RSD Radar System Data Receive RTE Routes Send Receive THS True Heading and Status Receive TTM Tracked Target Message Receive VDM AIS AIS VHF Data link Message Receive DO AIS AIS VHF Data link Own vessel Report Receive BW Dual Ground Water Speed Receive HW Water Speed and Heading Receive VSD AIS AIS voyage static data Send VTG Course Over Ground
119. tected and cannot be removed unless you have a CD DVD for the database available The option Remove Licenses will also be displayed in some instances Selecting this option and pressing Start will allow you to remove all chart licenses for the specified database Make sure you have new valid chart licenses available before starting this option 3 5 2 Transferring charts from CD DVD to USB flash drive Insert the chart CD DVD into the CD DVD drive of another computer onboard Also insert an empty USB flash drive in the same unit Use Windows filemanager to copy the contents of the CD DVD to the USB flash drive Move the flash drive to the TECDIS unit and use TECDIS Setup to transfer the charts as shown in chapter 3 5 1 3 5 5 Enter vessel information Vessel Name and Installed By is mandatory Owner information is required for chart subscriptions In this area information about the vessel owner should be entered This information is needed for chart licensing and warranty purposes Vessel Name Endeavor M S Installed By Furuno Norway IMO MMSI Callsign Vessel Type Owner Address City Area Country Notes X Cancel v Save Send Registration Complete the registration by sending the registration file to Telko AS or Furuno 3 5 4 Send registration When the vessel information has been entered and stored the option to send registration will be
120. tional description given for TECDIS AW system p Verify that required conning info according to NAUT AW requirements is displayed correctly ME Verify that requirements set forth in section 1 7 are fulfilled Additional checklist prior to completion of TECDIS AW installation completed Vessel Name ID Date of installation Name of technician Checklist performed Sign The checklist in section 6 3 shall be filled in and signed for all TECDIS AW installations in order to verify proper installation of the ECDIS system onboard Page 106 TECDIS Installation Manual 6 4 Installation Notes TECDIS Installation Manual Page 107 Page 108 TECDIS Installation Manual Revision History Revision 1 0 13 05 2005 e Initial revision Revision 1 1 17 06 2005 Illustrations updated e Wiring and signaling diagrams added Hardware installation for auxiliary components added e Some updates to setup software description Revision 1 2 29 08 2005 e Equipment list updated e Compass safe distance instructions added Revision 1 3 05 01 2006 Updated chapter 3 4 size and sensors New choices backward gyro 180 and Raise alarm if HDT1 HDT2 gt 2 5 e Updated illustrations in chapter 4 1 Revision 1 4 04
121. u want NOTE If you only want to change one specific port deselect set the change to all ports MOXA CP 114EL Series PCI Express Bus Properties General Ports Configuration Driver Details Resources Rx FIFO Level Tx FIFO Level Interface Termination Resistor 1 COM 4 h h 5 422 Disable 2 COM5 High High RS 422 Disable COME High High RS 422 Disable 4 COM High High RS 422 Disable Help Part Info rea stro Cancel g ELX130710 88 Computer ca Disk drives Display adapters DVD CD ROM drives A Ee 8 8 8 DR 3 9 RE RE RE E 92 Human Interface Devices Keyboards A Mice and other pointing devices VOC eee Multi port serial adapters MOXA CP 114EL Series PCI Express Bus 17 MOX Devices 777 Ports COM amp LPT Processors Smart card readers E Portable Sound video and game controllers lt gt Storage controllers gm System devices 9 Universal Serial Bus controllers current Auto Enumerating COM Number High Set the change to all ports Tx FIFO Level High Set the change to all ports Port Number Rx FIFO Level Interface Osa the change To all ports Termination Resistor Disable Set the change to all ports
122. up TECDIS NMEA server program Eee Ae on both main and back up TECDIS equipment are connected to a proper UPS main and back up TECDIS TECDIS Verify that alarm function on both main and back up TECDIS is working properly Check that TECDIS transmits alarm to external systems If installed verify generation of conning picture and correct display of sensor data on conning monitor check against engine telegraph speed repeaters gyro repeaters etc O Verify audible signal from alarm speaker on TECDIS Verify sensor data correct size of vessel etc is filled in on main and back up TECDIS Verify that back up of default setup values have been performed save setup default values on main and back up TECDIS Verify that installed charts have been correctly installed on both main and backup TECDIS if installed and that charts license matches Unplug TECDIS Service Key restart TECDIS to verify it starts up in normal mode chart program starts automatically and boat symbol and sensor data are displayed If video source switching is activated verify that an ECDIS label has been placed on the front bezel of the ECDIS monitor If connected to internet verify that a switch is available to disconnect TECDIS from internet when the connection is not in use Verify that Monitor Main and Monitor Back up comply with issued certificate and that hardware revision numbers comply with specification on page 11 14 in the TECD
123. verify that the grey box is clearly visible Check colors Open test diagram T All diagonal lines to clearly separate from background 3 Yellow diagonal lines 4 orange diagonal lines 3 magenta diagonal lines 4 green diagonal lines 3 blue diagonal lines 3 grey diagonal lines Page 94 TECDIS Installation Manual Check visibility of each color in the diagrams A E If the monitor fails the test it no longer meets the minimum requirements for display performance It should be evaluated by a qualified engineer and be repaired or replaced as necessary This test must be performed with all color palettes on the system day dusk night NB If monitor settings has been changed manually in the monitor menu or to make sure correct settings are used go to setup menu folder press Auxiliary and select recalibrate screen 5 3 Internet VSAT connection troubleshooting For all problems with downloading weather data or chart updates regardless of connection type used your TECDIS supplier and or Jeppesen Marine will be able to provide very useful assistance in tracking down the cause of weather download problems Logs kept by Jeppesen Marine will show whether your weather download attempts reach the weather data servers and whether the requests are successful They will also be able to verify that there are no problems with your subscriptions In order for Jeppesen Marine or your chart system supplier to he
124. vot point setting in NP5500 see chapter 3 1 2 51 1 the NP5500 Operator Unit Service Manual 3 1 2 46 Track C This must be set in accordance with the rudder Pivot point setting in NP5500 see chapter 3 1 2 51 1 the NP5500 Operator Unit Service Manual 3 1 2 51 Pivot point 3 1 2 52 Drift reset This must be set in accordance with the Pivot point setting in NP5500 see chapter 3 1 2 51 i the NP5500 Operator Unit Service Manual 3 1 2 66 Track Ship The Eff Ship Length setting in NP5500 is length available for Heading Control only This has to be adjusted as well TECDIS Installation Manual Page 51 1 9 NAUT AW Gyro Sensor Input Requirements For vessels with class notation NAUT AW the gyro sensor input to TECDIS AW must satisfy the following requirements 1 The GAS must be supplied with a redundant gyro system including 1 1 Heading monitoring function 1 2 Automatic correction for speed and latitude error 1 3 Automatic switching to back up gyro when selected gyro fails 1 4 Compliance with requirements to gyro system information system in use as stated in DNV rules Pt 6 Ch 8 Sec 6 H 600 1 4 1 Scope of paragraph 1 4 is to enable conning system to display which gyro is presently in use 2 equipment with gyro input must be supplied by the same gyro at given time to ensure a common reference point regarding heading information Page 52 TECDIS Installation Manual Chapter 2 Wiri
125. way from heat sources because of heat that can build up inside the cabinet Locate the equipment away from places subject to water splash and rain Determine the mounting location considering the length of the signal cable between the keyboard unit and the processor unit The length of the signal cable is 1 3 m Determine the mounting location considering the length of the signal cable between the trackball unit and the processor unit The length of the signal cable is 1 9 m When the combined keyboard and trackball Keytouch Panel Combo is installed the keyboard and the trackball must be connected separately to the main processor unit using separate USB cables in order to fully comply with type approvals For unit HD 24T21 MEC the keyboard and trackball should be connected using the included PS 2 adaptors Page 40 TECDIS Installation Manual 1 4 1 Outline dimensions for keyboard Cherry G84 4100 Approx 175 mm non curled UNNI LAI NN L N WW CN A EN LU UU UU ui Ji2 5 D SEO CS 2 0 _ _ a a a ML S S Le SES e Siz ve TS LUI TUTTI OTT k2 SS SS 2 e Nec _ _ Jo ae amg 7 SSI J LIEB 7 2 4 Cr sSTzNNC All dimensions mm Outline dimensions for Trackball TECDI

Download Pdf Manuals

image

Related Search

Related Contents

Viking Pump Technical Service Manual 320.1 for General Purpose  B&K 9130 User Manual  LG 42LM620T-ZE User's Manual  Samsung Celular E1260 manual do usuário(Oi)    the possibilities  Philips Ceramalux P-2220-E User's Manual  Télécharger - CD FFME 17  IstruzioneOptimat 2000  

Copyright © All rights reserved.
Failed to retrieve file