Home
MIRA User Manual 06-01-2015.pages
Contents
1. La lumencor MIRA Light Engine Instruction Manual UD jight jumencor Lumencor Inc Document Number 52 10028 Rev A www lumencor com lumencor Emissions Certifications This equipment has been tested and found to comply with the limits of EMC directive 2004 108 EC These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not in stalled and used in accordance with the instruction manual may cause harmful interference to radio communica tions Safety Certifications CB Scheme IEC 61010 1 201 0 CE Declaration of Conformity IEC 62471 TUV NRTL Listing UL 61010 1 201 2 TUV Canadian Listing CAN CSA C22 2 No 61010 1 2012 TUV European License EN 61010 1 2010 Lumencor Inc 14964 NW Greenbrier Parkway Beaverton OR 97006 T 503 213 4269 www lumencor com Document Number 52 10028 Rev A 1 MIRA Light Engine Instruction Manual lumencor Table of Contents Introduction Precautions and Warnings Installation and Operating Instructions Spectral Output Product Specifications Routine Maintenance and Trouble Shooting Customer Support Warranty O O N O OF FP NYO gt Declaration of Conformance MIRA Light Engine Instruction Manual lumencor 1 Introduction The Lumencor MIRA light engine
2. CONTROL OPERATION Quick Select Screen COLOR Consecutive presses of the COLOR button sequentially select the red green cyan violet and white red green cyan violet sources INTENSITY Consecutive presses of the INTENSITY button sequentially adjust the output power of the selected color source to 100 50 25 and 10 of maximum ON OFF Consecutive presses of the ON OFF button turn the source selected by the COLOR button on and off 1 SCREEN Consecutive presses of the SCREEN button change the screen background from white to gray and back 2 Single Select Screen OUTPUT One touch selection of red green cyan violet and white red green cyan violet sources INTENSITY One touch selection of 100 50 25 10 or 0 of maximum intensity for the source selected by the OUTPUT button Setup Screen RECONNECT Press RECONNECT if serial communication with the MIRA is lost or is not established by the initial connection process LE AUTO SHUTDOWN User may select a time interval from a drop down list after which the light engine output will be shut off without further user intervention TIME UNTIL DISPLAY DiIMS User may select a time interval from a drop down list after which the tablet display will be dimmed to conserve battery power NOTES 1 Any light sources that are ON when the app is exited will automatically be shut off 2 The gray screen background is useful in cases when subdued ambient lighting is required
3. PAS laisser tomber la source lumineuse Elle contient des composants optiques en verre sus ceptibles d tre endommag s ou d salign s par le choc r sultant d une chute sur une surface dure DISCLAIMER Lumencor shall not be liable for injury to the user or damage to the product resulting from the MIRA light engine being used in a way for which it was not intended and in complete disregard for all posted safety precautions and warnings AVIS DE NON RESPONSABILITE Lumencor d cline toute responsabilit pour les blessures corporelles ou les dommages au produit r sultant d une utilisation du MIRA autre que celle pr vue et du m pris total de toutes les mesures de s curite et mises en garde affich es 3 Operating Instructions The MIRA light engine ships with the following list of standard components 1 MIRA light engine configured with an output adapter for coupling to a specific microscope 2 AYV 4 45 A power supply Lumencor part no 27 1001 7 3 A6 ft AC power cord for the power supply for North American customers Lumencor part no 29 10002 for UK customers Lumencor part no 29 10004 and for European customers Lumencor part no 29 10005 3 1 Installation and Operation When setting up the MIRA light engine be sure that the adapter is securely attached to the appropriate illumination port of the microscope Usually this will be the fluorescence epi illumination port Be careful to properly support the MIRA light engine
4. is a compact solid state light source for fluorescence microscopy and other bioanalytical applications The MIRA light engine incorporates efficient thermal management requiring no fan and providing quiet and vibration free operation This enables direct coupling to the fluorescence epi illumination port of a microscope The light engine provides four distinct color bands of light output that are controlled using either manual control knobs on the side panel or the MIRA Control Tablet accessory The COLOR knob located on the side panel is used for on off control selection of color channels and enabling external tablet control The INTENSITY Knob orovides four different levels of output attenuation between 100 and 10 of maximum Model numbering for the MIRA light engine products are defined as follows MIRA 4 XXX FA The XXX denotes 000 999 and or AAA ZZZ and defines the light engine recipe F is any single aloha numeric and defines the light engine type while A is any aloha numeric which denotes the revision level 2 Precautions and Warnings Pr cautions et mises en garde A few simple practices will ensure trouble free operation for the life of the light engine Les quelques r gles simples suivantes permettront d assurer un fonctionnement fiable pendant toute la dur e de service de la source lumineuse Safety Instructions Please read and follow all safety instructions provided BEFORE using your new MIRA light engine Fai
5. UPE DE RISQUE 3 AVERTISSEMENT UV mis partir de ce produit viter de regarder et l exposition de la peau aux produits non blind e Ne pas regarder le t moin de sortie du moteur Risque de blessures aux yeux suite La luminosit de cette source de lumi re est plus lev que la plupart des luminaires et est destin deux directement dans un microscope o autre instrument bioanalytique Caution Label on MIRA Light Engine Package 4 MIRA Light Engine Instruction Manual lumencor Caution DO NOT open the unit There are no serviceable parts inside and opening the light engine enclosure will void the manufacturer s warranty Changes or modifications not expressly approved by Lumencor void the user s authority to operate the equipment Attention NE PAS ouvrir l appareil ne contient aucune pi ce r parable et l ouverture de son bo tier a pour effet d annuler la garantie Les changements ou modifications non approuv s express ment par Lumencor annuler l autorit de l utilisateur faire fonctionner l quipement Caution DO NOT set liquids on the light engine Spilled liquids may damage your light engine Attention NE PAS placer de liquide sur la source lumineuse Les liquides renvers s peuvent endommager la source lumineuse Caution DO NOT drop the light engine It contains glass optical components that could be damaged or mis aligned by the shock produced by a drop onto a hard surface Attention NE
6. and also conserves battery power 3 3 Using the Gate Connector The MIRA light engine output can be turned on off electronically using the electronic shutter function accessed through the BNC gate connector located on the rear panel A gt 3 3 V high signal applied to the BNC connector will turn the source on while a lt 1 5 V signal turns the source off The MIRA light engine can support an on off switching rate up to approximately 100 Hz Note that DC control levels applied to the gate connector DO NOT trigger selected color channels Light sources must first be enabled using the side panel COLOR control knob or the touchscreen control tablet Switching the gate connector to ground will then shut off light output Restoring the input level to gt 3 3 V will restart light output 9 MIRA Light Engine Instruction Manual Spectral Output of maximum 100 lumencor 4 Spectral Output The normalized spectrum shown below is representative of the MIRA light engine output External bandpass filters can be used to restrict the wavelength range of each color channel MIRA Light Engine Spectral Output Violet Cyan Green Red 350 400 450 500 550 600 650 Wavelength nm 10 MIRA Light Engine Instruction Manual lumencor 5 Product Specifications The MIRA light engine must be operated and stored within the environmental conditions specified Specification Temperature Operating Non operating Operating and non oper
7. ating Operating Non operating Dimensions WxLxH Lifetime Input Power Requirements Switching Speed Warm up Period Protection Sound Level Connections Warranty Detail D D O to 80 relative humidity non condensing D IP Rating of XO Sound Level at 1 m O db A USB A for MIRA Control Tablet and one BNC connection for TTL gating 12 months parts and labor for end users 6 Routine Maintenance and Troubleshooting Remove any built up dust or accumulation on the vent holes A vacuum may be used to remove debris so that a steady supply of air is available for cooling It is recommended that the vent holes be cleaned by a gentle suction device at least every 6 months and more often in dusty or smoke filled environments There are no user replaceable components or sub assemblies in MIRA light engines Opening the light engine enclosure will void the manufacturer s warranty MIRA Light Engine Instruction Manual lumencor 7 Customer Support For technical support of the MIRA light engine please contact Lumencor by phone at 503 213 4269 or through e mail at techsupport lumencor com Any light engine return to Lumencor for repair or refurbishment requires a re turn material authorization RMA number To request an RMA number submit the online request form at http lumencor com support lumencor rma request form Units that are returned to Lumencor without an RMA number will not be accepted Notification o
8. e responsibility that the MIRA light engine identified with the mark conforms to the following directives and regulations CB Scheme IEC 61010 1 2010 CE Declaration of Conformity EMC Directive 2004 108 EC Low Voltage Directive 2006 95 EC IEC EN 62471 2008 Photobiological Safety of Lamps and Lamp Systems Certification ROHS Directive 2002 95 EC REACH Registration Evaluation Authorization of Chemicals Regulation Directive 1907 2006 T V SUD America NRTL Listing UL 61010 1 2012 TUV SUD America Canadian Listing CAN CSA C22 2 No 61010 1 2012 TUV SUD America European License EN 61010 1 2010 September 25 2014 Claudia B Jaffe Ph D Executive Vice President 14964 NW Greenbrier Parkway Beaverton OR 97006 USA 13 MIRA Light Engine Instruction Manual
9. f RMA issuance together with shipping instructions will be sent to the customer e mail address provided on the request form It is the customer s responsibility to properly package and safely ship products to Lumencor The customer is responsible for selecting the method of shipment to Lumencor and paying for the shipment If it is determined that necessary repairs or refurbishment are covered by warranty then Lumencor will pay for return shipment to the customer For out of warranty service work Lumencor will evalu ate the light engine upon receipt and then provide a quotation for the cost of necessary repairs or refurbishment Work will not begin until a purchase order for the quoted services has been received 8 Warranty The MIRA light engine comes with a 12 month warranty starting from the date of shipment from Lumencor s factory in Beaverton OR 12 MIRA Light Engine Instruction Manual lumencor 9 Declaration of Conformance The presence of the CE Mark on a product means that this instrument has been designed tested and certified compliant to all applicable European Union CE regulations and recommendations Manufacturer Lumencor Inc 14964 NW Greenbrier Parkway Beaverton OR 97006 United States of America Product Name MIRA light engine Model Numbers MIRA 4 XXX FA Year mark affixed 2014 Type of Equipment Photo optical apparatus for illumination in research clinical and laboratory use We declare under our sol
10. ith the tablet Alternatively remove the DC charging adapter and plug the USB A M connector into a computer USB port The charge status of the tablet is indicated in the lower right hand corner of the MIRA control app screen see screenshot mage below 7 MIRA Light Engine Instruction Manual lumencor MIRA Touchscreen control tablet quick select screen Tablet to Light Engine Connection Insert the micro USB M end of the micro USB M to USB A F OTG cable into the tablet Connect the MIRA to the tablet using a USB A M to USB A M cable p n 29 10057 by inserting one end in the USB port marked external on the MIRA light engine and the other end in the USB A F receptacle of the OTG cable Connect the MIRA DC power supply and turn the COLOR control knob on the side panel of the MIRA from off to ext Next turn the tablet on and select the MIRA app from the Lumencor Light Engine Application Launcher Successful connection is indicated by opening of the Quick Select screen see above and the display of a Light Engine Active message onscreen for a few seconds If a connection is not obtained go to the Setup screen by pressing the selector button at the top of the screen and press the RECONNECT button The MIRA control app has 3 control screens selected by navigation buttons across the top of the screen and described in the tablet operations table below 8 MIRA Light Engine Instruction Manual lumencor MIRA TABLET OPERATIONS
11. lure to comply with the safety instructions may result in fire electrical shock or personal injury and may damage or impair protec tion provided by equipment Please save all safety instructions Instructions de s curit Veiller a lire et respecter toutes les instructions de s curit fournies AVANT d utiliser le nouveau MIRA afin d ca rter les risques d incendie de d charge lectrique de blessure corporelle et de possibles dommages ou d faillance de la protection offerte par l appareil Conserver toutes les instructions de s curit Safety Definitions D finitions relatives la s curit Warning Statements identify conditions or practices that could result in personal injury Avertissement d clarations qui identifient des situations ou des pratiques susceptibles d entra ner des blessures corporelles Caution Statements identify conditions or practices that could result in damage to your equipment Attention d clarations qui identifient des situations ou des pratiques susceptibles d endommager le mat riel 3 MIRA Light Engine Instruction Manual lumencor Safety Items Mesures de s curit Warning DO NOT use an unapproved power supply The Lumencor supplied external power supply is recommended for use with the MIRA light engine Alternative 9 VDC power supplies may be used provided that the current is limited to 4 45 max Also it is imperative that the alternative power supply has output over cur
12. posite ends of the knob range Both of these off settings turn the power completely off to the light engine Control Knobs Located on the Side Panel Take necessary precautions to protect yourself and others from the high intensity light when turning on the unit The MIRA light engine should be coupled to a microscope before it is turned on The INTENSITY control knob sets four different levels of output attenuation between 100 and 10 of maximum This setting is applied to the current Source selection according to the position of the COLOR knob It is recommended that the intensity be set to the 10 position when a source is first turned on and then increased as necessary This protocol will helo reduce the risk of damage to your eyes or a sample by gradually increasing the light output level BE AWARE that although the human visual system does not register the wavelengths of light from the violet color channel exposure can quickly produce eye damage 3 2 Operation Using the MIRA Control Tablet The MIRA light engine can be electronically controlled using the Control Tablet accessory Lumencor part no 83 10003 The MIRA light engine cannot be operated using a computer or third party software The external USB connector is designed for operation ONLY with the MIRA Control Tablet Charging the Tablet Connect the tablet to a wall power outlet using the USB A M to micro USB M cable and DC charging adapter supplied w
13. rent protection as the power input of the MIRA is not fused The equipment is required to be supplied by a DC power source that has been assessed to meet the requirements of a limited current circuit per clause 9 3 of IEC 61010 1 Connect the AC power cord to a receptacle with a protective safety earth ground terminal Avertissement NE PAS utiliser une alimentation lectrique non homologu e est conseill d utiliser l alimentation lectrique externe fournie par Lumencor avec la source lumineuse MIRA Il est possible d utiliser une autre alimentation lectrique continue 9 V condition que l intensit soit limit e 4 45 A maximum En outre il est imp ratif qu elle pr sente une protection de sortie contre les surintensit s car l entr e d alimentation du MIRA ne comporte pas de fusible Le mat riel doit tre aliment par une source d alimentation continue qui a t d clar e conforme aux crit res d un circuit d nergie limit e en vertu de la clause 9 3 de CEI 61010 1 Brancher le cordon lectrique sur une prise de courant prot g e par une borne de terre Warning RISK GROUP 3 WARNING UV emitted from this product Avoid eye and skin exposure to unshielded product Do not look at light engine output Eye injury may result The brightness of this light source is higher than most commercial lighting fixtures and is intended to couple directly into a microscope or other bioanalytical instrument Avertissement GRO
14. until it is mechanically coupled to the instrument 5 MIRA Light Engine Instruction Manual lumencor The MIRA light engine should be operated in an open area where airflow facilitates proper cooling Restricting the airflow will cause the unit to operate at elevated temperatures and could result in decreased product life and or oremature failure The power supply should be plugged into the DC power connector at the back of the light engine A green indicator light on the rear panel indicates that the light engine is powered on A yellow indicator light below the INTENSITY control Knob on the side panel alerts the user that light output is enabled lt x 3 power 9V 4 45A DC Cu WARRANTY Rear Panel of MIRA showing input receptacles for DC power supply USB connection to touchscreen control tablet external and electronic shutter gate Two control knobs are located on the side panel The COLOR knob allows the user to turn on the light output for any of the four color channels The selections are V for violet C for cyan QG for green and R for the red color channel The W setting is for white light when all four color bands are simultaneously illuminated The ext MIRA Light Engine Instruction Manual lumencor setting allows the MIRA light engine to be controlled using the MIRA Control Tablet see below There are two off settings at op
Download Pdf Manuals