Home

Quick Install Guide V1.0

image

Contents

1. 9 Tickets ee SED EHOTREAMER 110 Quick Install Guide Version 1 3 Advanced multiformat network audio decoder Package contents Exstreamer 10 Power supply RCA Stereo cable IR remote control Batteries 2 x AAA oan ao Cable Set AUDIO not included f Earphone g RCA Stereo cable h Network cable i Serial cable Firmware This device comes preloaded with the Streaming Client firmware Alternative firmware such as the standard Exstreamer firmware can be downloaded from www barix com Support For support please contact your local dealer or visit www barix com Barix AG 8 2009 all rights reserved All information is subject to change without notice All mentioned trademarks belong to their respective owners and are used for reference only Barix Exstreamer and SoniclP are trade marks of Barix AG Switzerland and are registered in certain countries Front view f ie Em A EXT R A t l Reset button A A brief press of the button will reset the device Holding the reset button pressed in for approximately 10 seconds will reset the device and restore the factory default settings when the B button is released 2 EXT USB interface solely for flash memory sticks not supplied 3 LCD Screen for status display 4 Headphone out Standard stereo mini jack 3 5 mm 5 IR sensor Sensor for the infared remote control N iim Rear view A B G D
2. Line out Stereo RCA line outputs RS 232 serial port DSub 9 pin male Pin Description TI Relay common e Not connected e Clear to Send CTS _ 9 Relay Normally Open Pin 4 will provide 2 6V less than the supplied voltage on Vin D but not more than 12V LAN port 10 100 Rj45 Standard RJ45 Ethernet socket Power Pin Description za Vin ring 2 Vin center pin 9 30 VDC 2 24 VAC l Installation STEP Plug a standard straight network cable h not included into the network port C of the Exstreamer and the other end into your hub or switch You can also use a crossover network cable not included for a direct connection to your PC STEP 2 i Plug standard headphones or the earphone f not included into the headphone output 4 and listen or ii Plug the RCA cable c into the LINE OUT outputs A and connect the cable to inputs of your mixing console or monitoring device and listen STEP 3 Connect the Power supply b to the device socket D and then to an appropriate electrical outlet STEP 4 The Exstreamer will now search for a DHCP server to get an IP address and announce it over the audio outputs as well as display it on the LCD screen Example 192 168 0 12 Voice one nine two Make sure you write this IP address down Proceed to section 2 Network configuration by web browser If you do not have a DHCP server running on your network you will still be able
3. g 192 168 0 2 STEP 2 Open a command window Windows click on Start click on Run in the Open field type cmd click on OK OSX Linux Open a terminal window STEP 3 Please proceed to step 4 if you used a crossover network cable in the preparation step above To ensure that we use a free IP address not already used by another device in the network we have to use the Ping command In this example we assume the PC to have the IP address 192 168 0 2 and want to check if 192 168 0 6 is free To do so type ping 192 168 0 6 and hit the Enter key If you get a reply IP already used then try to ping another IP until you find one that is not used If the request times out no reply then the pinged IP is free and we can continue with the next step STEP 4 Look for the Exstreamer s MAC address printed on a label placed on the bottom of the device 12 hex digits separated by a hyphen every 2 digits Type into the windows command window arp s 192 168 0 6 00 08 E1 00 B1 77 and hit the Enter key replace the digits according to your devices MAC address On a OSX or Linux system type into the terminal arp s 192 168 0 6 00 08 E1 00 B1 77 STEP 5 Now we have to make the Exstreamer listen to the IP address 192 168 0 6 using the Telnet command To do so type into the command window telnet 192 168 0 6 1 and hit the Enter key the number one m
4. r automatic discovery BootP DHCP STEP 4 In normal operating conditions leave the Netmask as is STEP 5 The Gateway primary and alternative DNS IP addresses as well as Sonic IP can be left at default for now STEP 6 Hit the Apply button to save all changes The Exstreamer will reboot with the Static IP address Please continue with section 5 Next steps on the last page 3 Iinfared remote control STEP Insert the batteries e into the remote control d observing the polarity requirements STEP 2 Read the firmware user manual for information about configuration of the IR sensor and the supported functions of the IR remote control 4 Setting temporary IP address using ARP command This procedure is used to temporarily set the IP address for first time browser access to the Exstreamer in the case where you have no audio cables connected and hence do not know the current IP address of the Exstreamer Attention After this procedure the temporary IP will be active only as long as the Exstreamer stays powered After a restart the procedure has to be repeated unless you have configured the IP address as described in the previous chapter Preparation Use either a crossover network cable between the Exstreamer and the PC or use two network cables to connect the Exstreamer and the PC to a network switch and power the Exstreamer STEP Make sure that you have a valid IP address configured on your PC e
5. to configure the Exstreamer This will involve assigning an IP address to the unit using one of 3 methods ARP see section 4 of this guide Telnet or a serial cable refer to the manual for these procedures Troubleshooting If no DHCP server is found then our IPzator function will search the network for a free IP address this could take up to 5 minutes If the IP address is not announced check if the right hand LED of the network port C is lit green If it stays dark check your network cabling If the front LCD 3 stays dark check the power cabling step 3 If still no IP address has been announced revert the device to its factory default settings by pressing the Reset button for about 10 seconds while the device is powered 2 Network configuration by web browser STEP Open your web browser STEP 2 Enter the IP address that was announced by the Ex streamer and press Enter ilies 192 168 0 12 e000 Barix Streaming Client CN A By E Hl CLIENT sac Norn y 14 am ne an avurrer parry a on the next to the section title Help NETWORK SETTINGS To obtain a quick insight into the configuration i i m i Ves SNe e jet to this ana click on the Danois tite Netmask 0 0 0 0 O E O hater al Visit www barix com choose the and do nerd depos ikoa aming Client ee to be found under the section Documeni STEP 3 Enter an IP address into the 4 IP address fields At default it is 0 0 0 0 fo
6. ust be there for this command to work correctly The Exstreamer will refuse the connection on port 1 immediately but will be available for web access on the IP address used as long as the device stays powered STEP 6 To check if the Exstreamer is responding you can use the ping command again To do so type ping 192 168 0 6 and hit the Enter key If you do get a reply the IP address 192 168 0 6 can be used to access the Exstreamer using a web browser Please go back to section 2 Network configuration by web browser If you do get request timed out then please repeat step 6 carefully you most likely mistyped the telnet command or repeat the entire procedure 5 Next steps Download the user manual from www barix com Read it to configure the Exstreamer for your purpose Check out the Barix user forum on www barix com for additional information For information about our products manuals technical documentations and latest version of firmware please visit www barix com Barix AG Seefeldstrasse 303 8008 Zurich SWITZERLAND www barix com