Home
1. DESCRIPTION 1.1. These electropumps have been designed to
Contents
1. placa conexiones Terminal box screw 65 tapa filtro Filter cover gasket 19 Tornillo caja conexiones Terminal case screw 66 filtro Filter cover 21 Prensa pasa cables Press cable bolt three phase 67 Palomilla filtro Filter thumb nut 26 Placa conexiones trif sica Terminal box three phase 70 Tap n purga bomba Drain plug pump 27 Puente placa conexiones Terminal box bridge 71 Junta tap n purga Pump drain plug gasket 28 caja conexiones trif sica Terminal case cover_three phase 74 din mica Sello mec nico Shaft seal rotating 29 Pasa cables trif sico Cable bolt three phase 75 Cara roce est tica Sello mec nico Shaft seal stationary 30 Anillo retenci n cojinete lado ventilador Ball bearing retention washer fan side 76 _ Junta Sello mec nico Shaft seal gasket 32 Junta caja conexiones Terminal box gasket 80 Sello completo Complete shaft seal 33 Tapeta cojinete motor Motor ball bearing cover 97 Junta filtro bomba Filter housing gasket 34 Tornillo tapeta cojinete Ball bearing cover screw 98 Esp rrago filtro bomba Filter housing screw 35 Tornillo coraza ventilador Fan cover screw 99 esp rrago filtro bomba Filter housing nut 36 motor lado bomba Motor cover side pump 100 Cuerpo filtro Filter housing 37 Brida fijaci n ventilador Fixing fan ring 101 Tornillo de ojo palomilla Filter screw 39 _ FD 18 Tuerca esp rrago cierre motor Motor nut screw 102 Pasador tornillo de ojo Filter screw bolt 40
2. F A 1 DESCRIPTION 1 1 These electropumps have been designed to recirculate lightly treated wa ter in private and public swimming pools 1 2 Technical characteristics MOTOR Power rating See motor plate Insulation Class F Operation Continuous Protection IP 55 Current Triphase see nameplate ra tings Consumption See motor plate Frecuency See motor plate R P M See motor plate Shaft Stainless steel Bearing Amoured ball bearing Atmospheric temperature Minimum1 C Maximum 40 C 2 1 Introduction This Handbook contains the instructions necessary for ins tallation use and maintenance of the swimming pool electropump In order to obtain the maximum performance shown in the Description of Characteristics it is necessary to fulfil and follow correctly all the recommendations given this Handbook This will allow operation with a safe and long lasting piece of equipment The equipment supplier will furnish the user with complementary information if required 2 2 Safety signs used in the handbook All instructions referring to possible risks to persons are highlighted by the fo llowing symbols PUMP Water temperature Minimum1 C Maximum 40 C Maximum pressure 2 1 bar Impeller model Closed Type of seal Mechanical Impeller Type FD Pump casing Type FD Prefilter Type FD Basket Stainless Steel pump characteristics pump characteristics
3. Standard DIN Danger Standard DIN 4844 W9 of 4844 w8 electrocution Other instructions in relation to the functioning of the equipment with which non compliance could cause physical damages are highlighted with the war ning ATTENTION 2 3 Nameplate ratings EEC 89 392 P 1 7 4 A The information given on the nameplate or other instructions affixed to the unit must be strictly complied with The content of these plates can usually be found in this Handbook Chapter 1 2 2 4 Liability Failure to comply with the instructions given by BOMBAS PSH in this Handbook in relation to the choice handling installation starting and maintenance of the unit shall release the manufacturer or distributor from all liability in respect of accidents suffered by persons or damages caused to other installations and in addition shall entail forfait of the warranty Danger in general 2 5 Standards Our swimming pool electropumps are manufactured in accor dance with the necessary requeriments for safety and health set forth in Community Directives 89 392 EEC 91 368 EEC assimilated into Spanish Law by Royal Decrees 1435 1992 and 93 44 EEC AN 3 1 Safety during operation of the machinery supplied can only be gua ranteed if it is used in accordance with the diagrams show Illustra tions It must never exceed the working conditions and limits given in this Handbook Chapter 1 2 Technical Characteristics Complia
4. 48 Soporte prensaestopa Press cable bracket 103 Tap n desagtie filtro Filter drain plug 49 Junta Press cable gasket 104 Junta tap n desagiie filtro Filter drain plug gasket 50 Paragoteo Throw off washer 105 Arandela esp rrago filtro bomba Filter pump washer 51 Tapa soporte Bracket cover 106 Esp rrago palomilla Thumb screw 120 Placa caracter sticas Characteristics card plate 3 2 MOD FD 3 000 r p m PLANO DE DESPIECE DETAIL DRAWING VUE ECLAT E DISEGNO ESPLOSO FD 17 18 POS DENOMINACI N DENOMINATION POS DENOMINACI N DENOMINATION 1 Eje rotor Shatf with rotor 51 soporte Bracket cover 2 Cojinete motor lado bomba Motor ball bearing pump side 52 Tornillo tapa soporte a motor Bracket screw 3 Cojinete motor lado ventilador Motor ball bearing fan side 54 Chaveta 0 Key 5 Tapa motor lado ventilador Back motor cover 55 Turbina Impeller Carcasa estator Motor case and winding 56 _ Arandela turbina Impeller washer 8 Ventilador Fan 57 Tuerca turbina Impeller nut 9 Esp rrago cierre motor Motor screw 61 Junta cuerpo bomba Pump housing gasket 10 Coraza ventilador Fan cover 62 Cuerpo bomba Pump housing 11 _ Tornillo tierra Ground screw 63 Esp rrago cuerpo bomba Pump housing screw 13 Tuerca placa conexiones Terminal box nut 64 filtro Filter basket 14
5. 22 and to the right clockwise for models FD 14 FD 15 and FD 16 with a wrench thus re leasing the impeller 55 this way the mechanical seal 74 is released too 9 ASSEMPLY ATTENTION All parts to be assembly must be clean and in perfect condition for use In order to assemble the pump e Assemble the mechanical seal 80 Press this 43 until its locates into the space the seal will have been lubricated with water beforehand e Assemble the impeller 55 on the shaft 1 affixing it with the key 57 impeller washer 56 and impeller nut 57 In this way the two halves of the mechanical seal are joined e Fix the motor to the pump casing 62 by means means of the four screws 63 impeller washer 56 and pump housing nut 107 10 SPARE PARTS To order any spare parts indication must be given of the part number shown on the detail drawing fig 3 and nameplate ratings 120 WARNING ALL THE ADJUSTEMENTS THAT ARE MADE TO THE EQUIPMENT MUST BE MADE BY THE AUTHORIZED TECNICAL SERVICE IF NOT THE GUARANTEE IS VOID AND WE ACCEPT RESPONSABILITY IF THE EQUIPEMENT IS USED FOR ANY OTHER MEANS THAN SPECI FIED BY THE MANUFACTURED THE PROTECTION OF THE EQUIP MENT COULD FAIL THEREFORE LOSING THE COVER OF GUARAN TEE D 3 gt MOD FD 3 000 r p m ILUSTRACIONES ILLUSTRATIONS ILLUSTRATIONS ILLUSTRAZIONI ETD TRIFASICO R R ui l U4 02 Tensi n W
6. Prensaestopa completo Complete press cable 103 Tap n desag e filtro Filter drain plug gasket 42 FD 18 Tornillo de c ncamo Eyebolt screw 104 Junta tap n desagiie Drain plug gasket 43 Ret n motor lado bomba Motor seal pump side 105 Arandela esp rrago filtro bomba Filter pump washer 44 Ret n motor lado ventilador Motor seal fan side 106 Esp rrago palomilla filtro Thumb screw 47 Arandela placa conexiones Terminal box washer 120 Placa de caracter sticas Characteristics card 50 Paragoteo Throw off cover washer MOD FD 3 000 r p m PLANO DE DESPIECE DETAIL DRAWING VUE ECLAT E DISEGNO ESPLOSO FD 19 5 24 i 120 OS DENOMINACI N DENOMINATION POS DENOMINACI N DENOMINATION 1 Ejerotor Shatf with rotor 48 Soporte prensaestopa Press cable bracket 2 Cojinete motor lado bomba Motor ball bearing pump side 49 _ Junta prensaestopa Press cable gasket 3 Cojinete motor lado ventilador Motor ball bearing fan side 50 Paragoteo l Throw off washer 5 Tapa motor lado ventilador Back motor cover 51 soporte Bracket cover 6 Carcasa estator Motor case and winding 52 _ Tornillo tapa soporte a motor Bracket screw 8 Ventilador Fan 54 Key 9 Esp rrago cierre motor Motor screw 55 Turbina Impeller 10 Coraza ventilador Fan cover 56 Arandela turbina Impeller washer 11 Tornillo tierra Grou
7. the water level a shut off valve will be placed on the suction pipe and another on the header pipe 5 3 Connection to the mains ATTENTION e In general terms the electrical installation will fully comply with the Regulations and Complementary Technical provisions appli cable and will be performed by an authorised Installer S B e The supply will have neutral and earth wires e The mains voltage must correspond to that shown on the nameplate rating for the equipment e The earth wire to be used must be sufficient to take without deterioration the current absorbed by the equipment see nameplate e The mains earth wire will be connected electrically to all metal parts of the equipment which should not be under current but which could accidentally be affected by the same and which are accessible to persons see figs 2 It is obligatory to install a protection and operation switchboard which will contain all necessary and recommended elements In general terms it will contain a General cut off or unipolar switch b Short circuit and overload protection devices for motors c 30mA differential high sensitivity switch d Others for monitoring and control The electrical characteristics of the protection devices and their regulation will comply with those for the motors to be protected and with the service condi tions envisaged for these and the instructions given by the manufacturer must
8. 73 210 319 120 130 735 515 80 200 16 9 R2GAS 383 62 84 144 273 210 327 128 130 762 555 100 20 180 9 100 20 180 19 420 76 84 144 288 210 327 128 190 817 64 100 20 180 9 100 220 180 19 420 72 119 176 288 210 331 132 190 831 72 125 250 210 9 100 220 180 19 466 72 112 176 290 250 360 132 190 876 85 125 20 210 9 100 220 180 19 466 173 140 216 312 250 360 132 190 918 5 125 20 210 9 100 20 180 19 466 173 140 216 312 250 360 132 190 918 100 125 20 210 9 100 20 180 19 466 173 178 216 312 250 360 132 190 956 110
9. C It is im portant for there to be sufficient space to permit the motor block to be dis mounted horizontally and the hair filter vertically see minimum space diagram in fig 1 5 2 Positions Installation ATTENTION The equipment or set of motor pump filter and selection valve will be insta Iled near the swimming pool at a distance of no more than 3 m from the sur face skimmers and preferably at a level of 0 5m never more than 3m below the level of the water in order to achieve its under load functioning The se lection valve junction and its connection to the nozzle and other accessories incorporated in the swimming pool will preferably be made in PVC pipe Pipe diameters will depend on flows The maximum water speed advisable in the pipes will be 1 2 m s in suction and 2m s in impulsion In any event the diameter of the suction pipe must not be less than the diameter of the pump nozzle The suction pipe must be perfectly watertight and must be installed with a downward inclination thus avoiding the formation of air pockets In perma nent installations with the pump positioned at a higher level than that of the water it is advisable for the longest strech of the suction pipe to be below the levels mentioned until it reaches the vertical pipe which coincides with the pump suction line The suction pipe can be either rigid or flexible with a reinforced coil to avoid contraction In fixed installations with the pump below
10. Esp rrago filtro bomba Filter housing screw 40 Prensaestopa completo Complete press cable 99 _ Tuerca esp rrago filtro bomba Filter housing nut 42 Tornillo de c ncamo Eyebolt screw 100 Cuerpo filtro Filter housing 43 Ret n motor lado bomba Motor seal pump side 101 Tornillo de ojo palomilla Filter screw 44 Ret n motor lado ventilador Motor seal fun side 102 Pasador tornillo de ojo Filter screw bolt 45 Tomillo tapa motor lado bomba Screw motor cover pump side 103 Tap n desag e filtro Filter drain plug 46 Tornillo tapa motor lado ventilador Screw motor cover fun side 104 Junta tap n desagiie Drain plug gasket 47 Arandela placa conexiones Terminal box washer 105 Arandela esp rrago filtro bomba Filter pump washer 48 Soporte prensaestopa Press cable bracket 120 Placa de caracter sticas Characteristics card FD 3 000 r p m CARACTER STICAS Y DIMENSIONES CHARACTERISTICS AND DIMENSIONS CARACTERISTIQUES ET DIMENSIONS CARATTERISTICHE E DIMENSIONI H1 H2 i Tapon 1 4 GA PA 14 15 16 2 H1 Tapon 1 4 GAS FD 17 18 19 20 21 22 BRIDA DE ASPIRACI N BRIDA DE IMPULSION DIMENSIONES EN mm DNA Da Ka la DNI DI K hi A B E F GiH L KG 80 200 16 9 R2GAS 383 62 84 144 273 20 319 120 130 735 50 80 200 16 9 R2GAS 383 62 84 144 2
11. U2 Me Tension Wwe menor 1 9 vo Y v1 7 5 Conexi n tri ngulo Conexi n estrella MOD FD 3 000 r p m PLANO DE DESPIECE DETAIL DRAWING VUE ECLAT E DISEGNO ESPLOSO FD 14 15 16 POS DENOMINACI N DENOMINATION POS DENOMINACI N DENOMINATION 1 _ Eje rotor Shatf with rotor 52 Tornillo tapa soporte a motor Bracket screw 2 Cojinete motor lado bomba Motor ball bearing pump side 54 Key 3 Cojinete motor lado ventilador Motor ball bearing fun side 55 Turbina Impeller 5 Tapa motor lado ventilador Back motor cover 56 Arandela turbina Impeller washer 6 Carcasa estator Motor case and winding 57 _ Tuerca turbina Impeller nut 8 Ventilador Fan 61 Junta cuerpo bomba Pump housing gasket 9 Esp rrago cierre motor Motor screw 62 bomba Pump housing 10 Coraza ventilador Fan cover 63 Esp rrago cuerpo bomba Pump housing screw 11 Tornillo tierra Ground screw 64 Cesta filtro Filter basket 13 Tuerca placa conexiones Terminal box nut 65 Junta tapa filtro Filter cover gasket 14 Tornilllo placa conexiones Terminal box screw 66 filtro Filter cover 19 Tornillo caja conexiones Terminal case screw 67 Palomilla filtro Filter thumb nut 21 Prensa pasa cables Press cable bolt three phase 70 Tap n purga bomba Drain plug pump 26 Placa conexiones trif sica Terminal b
12. be followed see nameplate In the case of equipment with triphase motors the motor winding intercon nection bridges must be suitably positioned see figs 2 e Conductor inlets and outlets at the bushing box will have stuffings to ensure the absence of damp and dirt and will therefore have a sealed casing e Conductors will have suitable terminals for connection to the bushings DM 6 STARTING Before connecting the equipment to the mains the following operations will be carried out e Check that the electrical conditions are correct e Manually check that the motor pump is not jammed 6 1 Pump priming ATTENTION Avoid blind functioning of the electro pump With the pump in the suction position above the water level of the swimming pool before starting remove the prefilter cover 66 fig 3 and slowly fill with clean water up to the level of the aspiration nozzle Close the cover 66 again and take care that it is hermetically closed ATTENTION With the pump below the swimming pool water level al AN ways with the cover 66 hermetically closed fill the pump by slowly ope ning the aspiration cut off valve with the header valve in the open position 6 2 ATTENTION The pump must not be started without the lumps and hair filter item 64 fig 3 since this could cause obstruction and would block the system 6 3 Direction of rotation ATTENTION Ensure that the motor shaft turns fre ely do not sta
13. d release the manufacturer or distributor from all liability 4 1 ATTENTION The manufacturer supplies the equipment protected in suitable packaging so that it is not damaged during transport or storage thus ensuring its correct ins tallation and or functioning 4 2 ATTENTION The user upon receipt of the equipment will immediately check the following oints e Condition of the outside packaging if this shows signs of serious deterioration he shall formally advise the person delivering the equipment He shall also check the condition of the contents should this show defects which would presumably prevent correct functioning he shall also formally no tify the supplier within a period not exceeding 8 days from the date of delivery 4 3 ATTENTION Storage conditions must ensure the optimum preservation of the equipment Due to its particular relevance we must stress that very damp atmospheres or others where extreme changes in temperatures which cause condensation must be avoided 5 1 Location ATTENTION The place where the electropump is to be located must be dry In all events there must be a drain in the floor as a prevention against flooding If the pump is to be located in a damp place a ventilation system must be provided in or der to prevent the formation of condensation In the case of very confined areas cold air can reach a low temperature which requires a ventilation system where by the it does not exceed 40
14. na Impeller washer 11 Tornillo tierra Ground screw 57 turbina Impeller nut 13 Tuerca placa conexiones Terminal box nut 61 Junta cuerpo bomba Pump housing screw 14 placa conexiones Terminal box screw 62 bomba Pump housing 19 Tornillo caja conexiones Terminal case screw 63 Esp rrago cuerpo bomba Pump housing screw 21 Prensa pasa cables Press cable bolt three phase 64 Cesta filtro Filter basket 26 Placa conexiones trif sica Terminal box three phase 65 Junta tapa filtro Filter cover gasket 27 placa conexiones Terminal box bridge 66 filtro Filter cover 28 conexiones trif sica Terminal case three phase 67 Palomilla filtro Filter thumb nut 29 Pasacables trif sico Cable bolt three phase 70 Tap n purga bomba Drain plug pump 20 Anillo ret cojinete lado ventilador Ball bearing retention washer fan side 71 Junta tap n purga bomba Gasket drain plug pump 32 Junta caja conexiones Terminal box gasket 74 Parte din mica Sello mec nico Shaft seal rotating 33 Tapeta cojinete motor Motor ball bearing cover 75 roce est tica Sello mec nico Shaft seal stationary 34 Tornillo tapeta cojinete Ball bearing cover screw 76 _ Junta Sello mec nico Shaft seal gasket 35 Tornillo fijaci n coraza Fan cover screw 80 Sello mec nico Complete shaft seal 36 Tapa motor lado bomba Motor cover pump side 97 _ Junta filtro bomba Filter housing gasket 37 Brida fijaci n ventilador Fixing fan ring 98
15. nce with the pro visions of Safety Standards in force in each country is mandatory A 3 2 Please ensure that the equipment selected is adequate for the used for witch it is intented and that its condition installation starting and subsequent use are correct See chapter 1 2 Technical Characteristics A 3 4 While the equipment is functioning it cannot be moved or reposi tioned These operations will be carried out at all times with the machi ne disconnected 3 3 Installation repair and maintenance operations will be carried out in all cases with the equipment disconnected from the mains Suction diameter According to the Delivery diameter According to the 3 5 Pressing of the electrical on off or safety elements will not be per formed where there is damp and special care must be taken for user s hands to be dry and also with footwear and surfaces with which the user is in contact 3 6 Those elements of the equipment which when functioning are in movement or which could reach dangerous temperatures will be pro tected with cages or casings which will prevent accidental contact with the sa me 3 7 Electricity conductors or parts which could carry current will be suitably insulated Other metal parts of the equipment will be correctly earthed 3 8 Spare parts that may be necessary will be originals from the manu facturer or those recommended by the manufacturer The use of others are not permitted an
16. nd screw 57 _ Tuerca turbina Impeller nut 13 Tuerca placa conexiones Terminal box nut 61 Junta cuerpo bomba Pump housing screw 14 Tornilllo placa conexiones Terminal box screw 62 Cuerpo bomba Pump housing 19 Tornillo caja conexiones Terminal case screw 63 Esp rrago cuerpo bomba Pump housing screw 21 Prensa pasa cables Press cable bolt 64 Cesta filtro Filter basket 26 Placa conexiones trif sica Terminal box three phase 65 Junta tapa filtro Filter cover gasket 27 placa conexiones Terminal box bridge 66 filtro Filter cover 28 conexiones trif sica Terminal case three phase 67 Palomilla filtro Filter thumb nut 29 Pasacables trif sico Cable bolt three phase 70 Tap n purga bomba Drain plug pump 30 Anillo ret cojinete lado ventilador Ball bearing retention washer fan side 71 Junta tap n purga bomba Drain plug pump gasket 32 Junta caja conexiones Terminal box gasket 74 din mica Sello mec nico Shaft seal rotating 33 Tapeta cojinete motor Motor ball bearing cover 75 roce est tica Sello mec nico Shaft seal stationary 34 Tornillo tapeta cojinete Ball bearing cover screw 76 _ Junta Sello mec nico Shaft seal gasket 35 Tornillo fijaci n coraza Fan cover screw 80 Sello completo Shaft seal complete 26 Tapa motor lado bomba Motor cover pump side 97 Junta filtro bomba Filter housing gasket 37 Brida fijaci n ventilador Fixing fan ring 98 Esp rrago filtro bomba Filter housing screw 39 _ T
17. ox three phase 71__ Junta tap n purga bomba Drain plug pump gasket 27 Puente placa conexiones Terminal box bridges 74 _ Parte din mica sello mec nico Shaft seal rotating 28 conexiones trif sica Terminal box cover three phase 75 Cara roce est tica sello mec nico Shaft seal stationary 29 _ Pasa cables trif sico Cable bolt three phase 76 Junta sello nec nico Shaft seal gasket 30 Anillo retenci n cojinete lado vent Ball bearing retention washer fan side 80 Sello completo Complete shaft seal 32 Junta caja conexiones Terminal box gasket 89 Contra brida impulsi n Impulsion flange 33 Tapeta cojinete motor Motor ball bearing cover 90 Junta brida impulsi n Impulsion flange gasket 34 Tornillo tapeta cojinete Ball bearing cover screw 91 _ Tomillo brida impulsi n Impulsion flange screw 35 Tornillo fijaci n coraza Fan cover screw 92 Tuerca tornillo brida impulsi n Impulsion flange nut 36 motor lado bomba Motor cover pump side 97 Junta filtro bomba Filter housing gasket 37 Brida fijaci n ventilador Fixing fan ring 98 Esp rrago filtro bomba Filter housing screw 40 Prensaestopa completo Complete press cable 99 Tuerca esp rrago filtro bomba Filter housing nut 43 Ret n motor lado bomba Motor seal pump side 100 Cuerpo filtro Filter housing 44 Ret n motor lado ventilador Motor seal fan side 101 Tornillo de ojo palomilla Filter screw 47 Arandela placa conexiones Terminal box washer 102 tornillo de ojo Filter screw bolt
18. rt the pump if it is blocked For this purpose electropumps have a groove at the end of the shaft on the ventilator side which permits it to be turned manually using a screwdriver fig 1 In triphase motors the impeller 55 can be unscrewed if the motors starts in the opposite direction Counter rotation can even damage the mechanical seal Start the motor for a few seconds and check that the direction of rotation coincides with that indi cated by the arrow on the ventilator cover Should this not be the case it is absolutely necessary to advise the authorised installer invert the connections between two phases 6 4 ATTENTION Check that the motor does not exceed the amperage indicated on the name plate rating 120 fig 3 otherwise regulate using the header valve A 7 MAINTENANCE CONSERVATION Before touching disconnect the electricity supply 7 1 ATTENTION Regularly check and clean the basket 64 To remove the basket place the valves and all other valves in the off position Loosen the cover 66 of the prefilter 100 remove the basket 64 and clean it under running water do not strike to avoid its dete rioration To re place the basket 64 introduce it gently untill it is in its original position Correctly place the joint 65 of the cover 66 and gre ase with vaseline Do not place the basket 64 in chemicals Please remember that changes in position of the valves will be made at all
19. times with the motor switched off 7 2 ATTENTION If the pump is switched off for long periods of time should there be a dan ger of frost the pump casing 62 should be emptied by losening the plug 69 103 along with their O ring seals Before starting the pump replace the plug 69 103 and their O ring seals Fill the prefilter 100 with wa ter and check with a screwdriver that the motor is not jammed If the shaft has seized up call a qualified technician In the event of the motor floo ding do not try to start it call an electrician to dismount the motor in or der to dry it 8 DISMOUNTING AN 8 1 ATTENTION Before performing any operation all valves must be in the off position having checked this e Disconnect the general electricity switch and the differential switch this must be done by an authorised specialist e Loosen and remove the supply cables on the connection box 26 fig 3 e Release the aspiration and impulsion sleeves e Empty the pump 8 2 ATTENTION In order to dismount and assemble the electropump please see the detail drawing Fig 3 In order to remove the motor from the hydraulic casing 62 remove the four screws 45 39 52 and lever so as to separate one part from the other one In order to dismount the impeller 55 hold the motor shaft 1 with the aid of a clamp while rotating the nut 57 to the left anticlockwise for mo dels FD17 FD 18 FD 19 FD 20 FD 21 and FD
20. uerca esp rrago cierre motor Motor nut screw 99 _ Tuerca esp rrago filtro bomba Filter housing nut 40 completo Complete press cable 100 Cuerpo filtro Filter housing 42 Tomillo de c ncamo Eyebolt screw 101 Tornillo de ojo palomilla Filter screw 43 Ret n motor lado bomba Motor seal pump side 102 Pasador tornillo de ojo Filter screw bolt 44 Ret n motor lado ventilador Motor seal fun side 103 Tap n desagiie filtro Filter drain plug 47 Arandela placa conexiones Terminal box washer 104 Junta tap n desag e Drain plug gasket 105 Arandela esp rrago filtro bomba Filter pump washer 120 Placa de caracter sticas Characteristics card MOD FD 3 000 r p m PLANO DE DESPIECE DETAIL DRAWING VUE ECLAT E DISEGNO ESPLOSO FD 20 21 22 34 i 120 POS DENOMINACI N DENOMINATION POS DENOMINACI N DENOMINATION 1 Ee rotor Shatf with rotor 49 _ Junta prensaestopa Press cable gasket 2 Cojinete motor lado bomba Motor ball bearing pump side 50 Paragoteo Throw oft washer 3 Cojinete motor lado ventilador Motor ball bearing fan side 51 soporte Bracket cover 5 Tapa motor lado ventilador Back motor cover 52 Tornillo tapa soporte a motor Bracket screw 6 Carcasa estator Motor case and winding 54 Key 8 Ventilador Fan 55 Turbina Impeller 10 Coraza ventilador Fan cover 56 Arandela turbi