1. Power Technologies From Para Systems Inc MMS620V16PC6 MMPD615V12PC6 MMPD2020V60DCL User s Manual Para Systems Inc 1455 LeMay Dr Oe ce a Carrollton TX 75007 IH Phone 1 972 446 7363 Fax 1 972 446 9011 Internet minutemanups com UPS Sizing sizemyups com PN 34000303 Table of Contents Important Safety Instructions uussnressnnsennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nennen 1 1ntroduction 2 ee ke ee 2 Introduction to the Front Panel ee aa naaa 3 Installation and Operation uur u4r24440annnnnnnnnnnnnannnnnnnnnnnnnnnn nn IAN WAPACKING ranei a AA Aa dididra 3 2 Selecting Installation Position aaa 3 3 Installation na ta nt Sel esate tees 3 3 1 Vertical Mounting ia 3 4 Connecting the EquipMeNt oooooocccnconoccoccccccnccnonnononononcnnnnnnnonnnncnnnnnnnns 3 5 Connecting to the Power Source aan A TFOUBIESMOOUING AWA Appendix re AT Specifications diia as A 2 Obtaining Servite timida a tdi A 3 Limited Lifetime Warranty aaa A 4 Declaration of Conformity esa O Copyright Para Systems Inc 2006 1 IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions that should be followed during the installation and the operation of the Power Distribution Unit PDU SAVE THESE INSTRUCTIONS e To ensure safety in all applications where
2. a PDU is hardwired to the Electrical Supply ensure that a Qualified Service Personnel installs the system e The PDU systems supplied with a power cord can be safely connected to the wall outlet by the user e Make sure that the AC Utility outlet is properly grounded e Do not open the unit there are no serviceable parts inside This will void the warranty e Donottry to repair the unit yourself see Obtaining Service e Please make sure that the input voltage of the PDU matches the supply voltage e Use a certified input power cord with the correct plugs and sockets for the appropriate voltage system e Make sure the PDU is installed in the proper environment as specified 0 40 C and 0 90 non condensing humidity e Do not install the PDU in direct sunlight e Install the PDU indoors as it is not designed for outdoor use e This PDU supports electronic equipment in offices telecommunications process control medical security and IT applications e This PDU is intended for use in a Controlled Environment e Servicing of PDU must be performed by Qualified Service Personnel Only e CAUTION To reduce the risk of fire connect only to a branch circuit with over current protection in accordance with the National Electric Code ANSI NFPA 70 3KVA e CAUTION Connect the PDU to a two pole three wire grounding AC wall outlet The receptacle must be connected to the appropriate branch protection circuit breaker or fuse Connection t
3. ara Systems equipment is furnished without charge and on the basis that it represents Para Systems best judgment under the circumstances but it is used at the recipient s sole risk EXCEPT AS PROVIDED HEREIN PARA SYSTEMS MAKES NO WARRANTIES EXPRESSED OR IMPLIED INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Some states do not permit limitation of implied warranties therefore the aforesaid limitation s may not apply to the purchaser EXCEPT AS PROVIDED ABOVE IN NO EVENT WILL PARA SYSTEMS BE LIABLE FOR DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Specifically Para Systems is not liable for any costs such as lost profits or revenue loss of equipment loss of use of equipment loss of software loss of data cost of substitutes claims by third parties or otherwise The sole and exclusive remedy for breach of any warranty expressed or implied concerning Para Systems products and the only obligation of Para Systems hereunder shall be the repair or replacement of defective equipment components or parts or at Para Systems option refund of the purchase price or substitution with an equivalent replacement product This warranty gives you specific legal rights and you may also have other rights which vary from state to state 10 A 4 Declaration of Conformity Application of Council Di
4. arrollton TX 75007 ATTN RMA A 3 Limited Lifetime Product Warranty Para Systems Inc Para Systems warrants this equipment when properly applied and operated within specified conditions against faulty materials or workmanship for Lifetime from the date of purchase certain conditions apply For equipment sites within the United States and Canada this warranty covers repair or replacement of defective equipment at the discretion of Para Systems Repair will be from the nearest authorized service center Replacement parts and warranty labor will be borne by Para Systems For equipment located outside of the United States and Canada Para Systems only covers faulty parts Para Systems products repaired or replaced pursuant to this warranty shall be warranted for Lifetime applying to the original product This warranty applies only to the original purchaser who must have properly registered the product within 10 days of purchase The warranty shall be void if a the equipment is damaged by the customer is improperly used is subjected to an adverse operating environment or is operated outside the limits of its electrical specifications b the equipment is repaired or modified by anyone other than Para Systems or Para Systems approved personnel or c has been used in a manner contrary to the product s User s Manual or other written instructions Any technical advice furnished before or after delivery in regard to use or application of P
5. breaker Over current protection Output receptacles To connect the equipment Power Switch To turn the PDU On Off Surge LED green The LED is illuminated when providing Surge protection The LED is off when the Surge protection devices are damaged or if the utility power is not present 7 Power On LED green The LED is illuminated when the utility power is present The LED is off when the utility power is not present Aaa ai Chapter Three Installation and Operation The packing condition and the external outlook of the PDU should be inspected carefully before installation Retain the packing material for future use 3 1 Unpacking 1 Take the PDU out of the box 2 Remove the PDU from the plastic bag Use CAUTION the plastic bag holding the PDU is very slippery so be careful in unpacking and handling the PDU 3 Standard Package includes PDU Vertical Mount 0U mounting hardware User s Manual Warranty Document Platinum Protection Document if applicable var 3 2 Selecting Installation Position The Minuteman PDU Series is intended to be install in a temperature controlled environment that is free of conductive contaminants Avoid locations near heating devices water or excessive humidity or where the PDU is exposed to direct sunlight Route power cords so they cannot be walked on or damaged Operating Temperature Max 0 to 40 degrees C 32 to 104 degrees F Operating Eleva
6. e Do not use extension cords adapter plugs or surge strips The PDU has an external ground stud for attaching an external ground wire from the rack to the PDU NOTE Each individual input power cord for the dual circuit PDU MMPD2020V60DCL must be connected to its own Branch Circuit Turn the Power Switch to the on position Not on all models The Power On LED green will illuminate indicating that the PDU is on and providing power to the connected equipment Not on all models 4 The Surge LED green will illuminate indicating that the PDU is on and providing surge protection to the connected equipment Not on all models Turn on the connected equipment The installation is complete the PDU is ready for normal operation D m Chapter Four Troubleshooting If the PDU malfunctions check the list below to resolve the problem Should the problem persist call for service Situation Check Items Solution Power On LED is not on 1 Input power cord not 1 Connect the Input power and there is no output plugged in to the wall outlet cord to the wall outlet power 2 Input circuit breaker is 2 Unplug the input power cord tripped and reset the input circuit 3 The circuit breaker at the breaker Connect the Input service panel is tripped power cord to the wall outlet 4 No Utility power available 3 Unplug the input power cord and reset the circuit breaker at the service panel Connect the Input power cord to the
7. mum Load Capacity Number of Phases Nominal Voltage Frequency Input Protection Surge Energy N A Nominal Voltage 120VAC Frequency Branch Circuit Protection Circuit Quantity Operating Temperature 32 104 F 0 40 C Storage Temperature 32 149 F 0 65 C Operating Storage 0 90 non condensing Humidity 0 to 3 000m 0 to 10 000 ft 0 to 15 000m 0 to 50 000 ft Operating Elevation Storage Elevation Input Power Cord 6 feet NEMA 5 15P NEMA 5 20P 6 6 NEMA 5 15R NEMA 5 15 20R Vertical Zero U Output Receptacles Mounting Format Net Dimension 12 0 x 1 64 x 1 5 16 0 x 1 64 x 1 5 LxWxH 304 8 x 41 4 x 38 1 mm 400 0 x 41 4 x 38 1 mm Net Weight Lbs 1 32 1 98 0 60 0 90 Ship Dimensions 12 60 x 4 80 x 3 07 16 53 x 4 80 x 3 07 LxWxH 320 x 122 x 78 mm 420 x 122 x 78 mm Ship Weight Lbs 2 0 3 0 Safety Approvals UL 60950 1 UL 1449 UL 60950 1 cUL CSA 22 2 CE cUL CSA 22 2 CE Specifications are subject to change without prior notice A 2 Obtaining Service If the PDU requires Service 1 Use the TROUBLESHOOTING section to eliminate obvious causes 2 Verify there are no circuit breakers tripped A tripped circuit breaker is the most common problem 3 Call your dealer for assistance If you cannot reach your dealer or if they cannot resolve the problem call or fax MINUTEMAN Technical Support at the following numbers Voice phone 972 446 7363 FAX line 972 446 9011 o
8. o any other type of receptacle may result in a shock hazard and violate local electrical codes Do not use extension cords adapter plugs or surge strips e CAUTION To reduce the risk of electrical shock with the installation of this PDU equipment and the connected equipment the user must ensure that the combined sum of the AC leakage current does not exceed 3 5mA e CAUTION To de energize the outputs of the PDU Disconnect the PDU from the AC wall outlet Receiving Inspection After removing your MINUTEMAN PDU from its carton it should be inspected for damage that may have occurred in shipping Immediately notify the carrier and place of purchase if any damage is found Warranty claims for damage caused by the carrier will not be honored The packing materials that your PDU was shipped in are carefully designed to minimize any shipping damage In the unlikely case that the PDU needs to be returned to MINUTEMAN please use the original packing material Since MINUTEMAN is not responsible for shipping damage incurred when the system is returned the original packing material is inexpensive insurance PLEASE SAVE THE PACKING MATERIALS Para Systems Life Support Policy As a general policy Para Systems Inc Para Systems does not recommend the use of any of its products in life support applications where failure or malfunction of the Para Systems product can be reasonably expected to cause failure of the life support device or to significan
9. onnections other than direct connections to the branch circuit e g use of power strips 3 3 Installation 3 3 1 Vertical Mounting 0 zero U Side Mounting 1 Snap on the OU mounting brackets to the backside of the PDU as shown 2 Orient the PDU to the desire position and then attach the PDU to the rack with the retaining screws provided as shown 3 The installation is complete See Connecting the Equipment 0000000000000 200000 A Side Mount Flush Mount Flush Mounting 1 Align the center hole of the OU mounting brackets backside to the mounting hole on the rack Attach the OU mounting bracket to the rack with the retaining screws provided 2 Snap the PDU into the OU mounting bracket 3 The installation is complete See Connecting the Equipment 3 4 Connecting the Equipment Plug the equipment into the output receptacles on the PDU Do not use extension cords adapter plugs or surge strips on the output of the PDU Ensure that the load does not exceed the maximum output rating of the PDU refer to the information label on the PDU or the Electrical Specifications in this manual 3 5 Connecting to the Power Source 1 Verify that the voltage and frequency ratings match that of the Utility power and then connect the AC Input power cord into a two pole three wire grounded receptacle only The receptacle shall be installed near to the PDU and shall be easily accessibl
10. r contact Minuteman UPS at mmsupport minutemanups com Please have the following information available BEFORE calling the Technical Support Department A Your name and address B Where and when the unit was purchased C All of the model information about your PDU D Any information on the failure including LEDs that may not be illuminated E A description of the protected equipment including model numbers if possible F A technician will ask you for the above information and if possible help solve your problem over the phone In the event that the unit requires factory service the technician will issue you a Return Material Authorization Number RMA G If the PDU is under warranty the repairs will be done at no charge If not there will be a charge for repair 4 Pack the PDU in its original packaging If the original packaging is no longer available ask the Technical Support Technician about obtaining a new set It is important to pack the PDU properly in order to avoid damage in transit Never use Styrofoam beads for a packing material A Include a letter with your name address daytime phone number RMA number a copy of your original sales receipt and a brief description of the problem 5 Mark the RMA on the outside of all packages The factory cannot accept any package without the RMA marked on the outside 6 Return the PDU by insured prepaid carrier to Para Systems Inc MINUTEMAN UPS 1455 LeMay Drive C
11. rective s UL Standard s to which Conformity is declared UL 60950 1 cUL UL1449 UL1449 is for Surge models only Manufacturer s Name Para Systems Inc MINUTEMAN UPS Manufacturer s Address 1455 LeMay Drive Carrollton Texas 75007 USA Type of Equipment Information Technology Equipment Model No MMPD615V12PC6 MMS620V16PC6 MMPD2020V60DCL Year of Manufacture Beginning January 1 2007 l hereby declare that the equipment specified above conforms to the above Directive s Robert Calhoun Robert Calhoun Name Signature Manager Engineering Date January 1 2007 Position Place Carrollton Texas USA 11 NOTES
12. tion 0 to 3 000m 0 to 10 000 ft Operating and Storage Relative Humidity 0 90 non condensing Storage Temperature 0 to 65 degrees C 32 to 149 degrees F Storage Elevation 0 to 15 000m 0 to 50 000 ft Rack Mount Instructions The following or similar rackmount instructions are included with the installation instructions a Elevated Operating Ambient If installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient Therefore consideration should be given to installing the equipment in an environment compatible with the maximum ambient temperature Tma specified by the manufacturer b Reduced Air Flow Installation of the equipment in a rack should be such that the amount of airflow required for safe operation of the equipment is not compromised c Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading d Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on over current protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern e Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply c
13. tly affect its safety or effectiveness Para Systems does not recommend the use of any of its products in direct patient care Para Systems will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Para Systems that a the risks of injury or damage have been minimized b the customer assumes all such risks and c the liability of Para Systems Inc is adequately protected under the circumstances Chapter One Introduction Thank you for purchasing a MINUTEMAN Power Distribution Unit PDU product It has been designed and manufactured to provide many years of trouble free service Please read this manual before installing your MMPD or MMS Series PDU models MMPD615V12PC6 MMS620V16PC6 MMPD2020V60DCL as it provides important information that should be followed during installation and operation of the PDU allowing you to correctly set up your system for the maximum safety and performance Included is information on customer support and factory service if it is required If you experience a problem with the PDU please refer to the Troubleshooting guide in this manual to correct the problem or collect enough information so that the MINUTEMAN Technical Support Department can rapidly assist you Chapter Two Introduction to the Front Panel 1 2 3 4 External Ground Stud To connect an external ground wire Input Power Cord To connect to Utility Circuit
14. wall outlet 4 Contact your local Utility company Safety Approvals The Power On LED is off There is an internal fault call but there is output power for Service One of the connect With a voltmeter check the 1 lf there is an AC voltage at equipment does not turnloutput receptacle for an AC the output receptacle check on voltage the connected equipment 2 If there is not an AC voltage at the output receptacle there is an internal fault call for Service The Surge Protection LED The surge protection devices is off are blown call for Service Appendix A 1 Specifications Model Number MMPD2020V60DCL Maximum Load Capacity 16Amps per circuit INPUT PARAMETERS Number of Phases Nominal Voltage Frequency Input Protection OUTPUT PARAMETERS 120VAC Nominal Voltage Frequency 50 60Hz Branch Circuit Protection UL 60950 1 Circuit Quantity 2 16Amp circuits ENVIRONMENTAL Operating Temperature Storage Temperature Operating Storage Humidity Operating Elevation Storage Elevation PHYSICAL Input Power Cords 15 feet 2 Input Plugs NEMA L5 20P 2 Output Receptacles 20 Total 10 per circuit NEMA 5 15 20R Mounting Format Vertical Zero U LXWxH 1524 0 x 41 4 x 38 1 mm Lbs Kgs 3 70 Ship Dimensions 63 27 x 4 80 x 3 07 LxWxH 1607 x 122 x 78 mm Ship Weight 9 0 Lbs Kgs 3 87 REGULATORY COMPLIANCE UL 60950 1 cUL CSA 22 2 CE Model Number Maxi

Download Pdf Manuals

image

Related Search

Related Contents

Westinghouse L1928NV Computer Monitor User Manual  Ficha Securitesa 1 Automatica.FH11  Pelco TLR2024 User's Manual  FAX System(V) - TA Triumph  d - Fiamma  Odacio 3 Food Processor Instructions and Recipes  SHーMP。  GSK988T User Manual - Installation & Debugging  Link zum Manual  Terratec Cinergy 800i PVR  