Home

User Manual Of Smart Charger (15A) for 25.6V (8 cells) LiFePO4

image

Contents

1. 70 RH Storage temperature 10 C 60 C Without conductive dust Without explosive dust Without corrosive gas and steam damaged to metal and isolator keep away from rain and snow OAE A E A A AE IE aE i Mounting slop S5 degree Maintenance and service The charger must be set at ventilated dry and dust less place to prevent the reduction of the performance of the charger For technical support please contact us via sales batteryspace com
2. User Manual Of Smart Charger 15A for 25 6V 8 cells LiFeP04 Battery Pack 110V only Standard Anderson plug AA Portable Power Corp AA Portable Power Corp http www batteryspace com Address 860 S 19 St Unit A Richmond CA 94804 Tel 510 525 2328 Fax 510 439 2808 Email Sales batteryspace com Prepared amp Approved by Louis 01 10 08 a mon If failure or error of this instrument could result in a critical accident of the system install a external protection circuit to prevent such an accident In order to prevent instrument damage or failure protect the power line and the input output lines from high currents by using fuses with appropriate ratings Power supply In order to prevent instrument damage or failure supply power of the specified rating In order to prevent electric shock or instrument failure do not turn on the power supply until all of the wiring is completed Never use the instrument near inflammable gases In order to prevent fire explosion or instrument damage never use this instrument at a location where inflammable or explosive gases or vapour exist Never touch the inside of the instrument In order to prevent electric shock or burns never touch the inside of the instrument only authorized service engineers can touch the inside of the instrument to check the circuit or to replace parts High voltage and high temperature sections inside the instrument are extremely dangerous Nev
3. er modify instrument In order to prevent accident or instrument failure never modify the instrument Maintenance In order to prevent electric shock burns or instrument failure Only authorized service engineers may replace parts In order to use this instrument continuously and safely conduct periodic maintenance Some parts used in this instrument have a limited service life and may deteriorate over time Wiring precautions Introduction AA Portable Power Corp http www batteryspace com specialized in the research amp development of the intelligence battery charger in the long terms The series battery charger is based on MCU technology with pulse charging mode the charging voltage has temperature compensation automatically It could be used in the various electric cars the field of tourism railway mine post and telecommunication Main Feature INPUT mM AC input voltage 90 to 130 VAC single phase E Input frequency 47 to 63 Hz E Efficiency 72 min at rating power 115Vac 60Hz OUTPUT mM CCCV charging mode E Cut off voltage 29 6VDC E 15A current Max E Charge terminal long 8AWG wire 1 9 x 1 5 x 0 6 Standard Anderson connector CHARGE Anderson plug dimension LxWxH 1 9 48 Omm x 1 5 38 Omm x 0 6 15 Omm Included 1 pcs 1 9 x 1 5 x 0 6 Standard Anderson connector without wire for DIY use Tip In order to match up the charge
4. r s connector You may connect the battery pack charge terminal with Included 1 pcs 1 9 x 1 5 x 0 6 Standard Andersen connector Make sure the charge DIY wire will be acceptable for 15A Max charge current Warning Wrong polarity will damage the charger and Batteryspace are not responsible for the damage or losses caused by misusing Note Anderson connector has no difference in male and female which can mate each other E The Battery range is between 20AH to 40AH M Reverse Polarity Protection mM Short Circuit Protection E No trigger voltage requirement Built in cooling fan to ensure charger long service life Dimension LxWxH 210mm 8 3 x 174mm 6 9 x 76mm 3 0 Weight 5 2lb 2358grams How to use 1 Turn on Make sure the pack voltage is suitable for charger Then connect to the pack with correct polarity 2 Check the voltage of the AC input is suitable for the input voltage of the charger or not 3 The charger start ramp charging after auto testing in 1 minutes 4 Indicating LED signification 5 Power indicating and battery test LED Green LED Fully charged Correct Polarity Connection Red LED Charging Wrong polarity Connection Orange LED 90 fully charged 6 Turn off After Battery is fully charged must disconnect the AC power supply before disconnect battery Operation environment Above the sea level lt 2000m Ambient temperature 10 C 50 C Ambient humidity 5

Download Pdf Manuals

image

Related Search

Related Contents

metodologie e tecniche jini per la progettazione di agenzie domotiche  User Manual Revolution (classic) - click here to  Avaya 70V User's Manual  取扱説明書  FUMOIR FUMOIR  Olympus IS-10 Operating Instructions    Le conseil de gestion aux exploitations agricoles - Agritrop  Whirlpool 2DLSQ8000JQ0 User's Manual  FDKN(PDF/253KB)  

Copyright © All rights reserved.
Failed to retrieve file