Home

T - PCE Instruments

image

Contents

1. Computer balance indication in the following format 16 Bytes Byte Byte Byte Byte Byte Byte Byte Byte Byte sign or space space digit or space digit decimal point or space digit k c p or space g b t cor CR ODh LF OAh 13 PCE info tursdaletechnicalservices co uk It is possible to use transmission protocol other then LonG on customer s demand e g Farb protocol used for cooperation with automatic paint mixer continuous transmission Send option transmission speed 2400bps additional sign in first byte Connection cable WK 1 balance computer 9 pin Balance Computer Connection cable WD 1 balance PCE BP1 printer Balance Printer PCE BP1 14 Special functions description All balances beside basic functions like weighing and tare are equipped with the set of additional functions calibration pieces counting autozeroing and serial port working mode setting Other functions recipe ingredients summing density calculation and other special functions can be enabled as an option on customer request described in additional brochure when ordered To display all available function enter Function Menu with F key Functions are displayed with successive numbers F1 LIC F2 AUt etc When special functions are displayed MODE indicator is displayed To make clear how to manage with each function in further part of instruction descriptions are replaced
2. PCE LSZ 1000C PCE LSZ 4000C pan supports Apcs and pan Antiblast glass draft shield with lid PCE LSZ 100C PCE LSZ 500C Feeder ZN 12V 500mA User Manual Guarantee card occ 3 Balance description Front view PCE LSZ 100C PCE LSZ 600C Front view PCE LSZ 1000C PCE LSZ 4000C PCE info tursdaletechnicalservices co uk 1 pan 2 pan support 3 pan ring 4 LCD display o keys 6 rotating legs 7 water level 8 antiblast shield Note PCE LSZ 600C does not have the pan ring and the antiblast shield 1 pan 2 pan supports 4 LCD display o keys 6 rotating legs 7 water level Rear view Feeder 230V Feeder Adjustation switch ON OFF 12V 500mA info a tursdaletechnicalservices co uk Computer or printer N RS232C RxD receiver TxD send Mass Housing PCE info tursdaletechnicalservices co uk 4 Keys and indicators i ad MODE Max Min e d dD te e v pe vo Basic functions T lt tare subtract package weight from weighed mass 0 zeroing balances for direct sale use only L gt data output print transmission y internal calibration Menu Menu VO switch on switch off standby indicator result stabilisation bar indicator load indicator 0 100 indicator OFF stand by mode Max Min d e metrologic
3. parameters and accuracy class When entering numeric values use the keys as described below Ld change digit value E decimal point move to the next position MENU end PCE info tursdaletechnicalservices co uk 5 Technical data Verification unit S Wcwaydas O OOS S oO os Balance base dim 215 235 x345x90mm including legs gm 230V 50Hz 9VA 12V 300mA Calibration weight F2 100g F2 200g F2 200g F1 500g OIML PCELSZ 1000 capacity ax 600g 10009 0 5 m s e Tare range 600g 10009 20000 30000 40000 Accuracy class o Moo temperature Balance base 215 235 x845x90mm dim including legs 230V 50Hz 9VA 12V 300mA Calibration F2 500g F2 1000g F2 2000g weight OIML PCE info tursdaletechnicalservices co uk 6 Security rules To avoid electrical shock or damage of the balance or connected peripheral devices it is necessary to follow the security rules below For power supply use only a socket with a ground contact All repairs and necessary regulations can be made by authorised personnel only To avoid fire risk use a feeder of an appropriate type supplied with the balance Pay attention that supply voltage is compatible with specified technical data Do not use the balance when its cover is opened Do not use the balance in explosive conditions Do not use the balance in high humidity If the balance seems not to operate
4. bidden to make any repairs by unauthorised persons 6 To repair the balance please contact our nearest service Error communicates uL selftests failed if displayed more than 1 minute over 1 min contact an authorised service mechanical damage contact an authorised service overloading remove the load from the pan mechanical damage contact an authorised service the pan is not empty remove a load from the pan unstable ground place the balance on a stable e n vibrations ground not affected by mechanical air flows vibrations and airflows indicator does not appear balance damage contact an authorised service boe taring in progress as above 17 PCE info tursdaletechnicalservices co uk Declaration of Conformity C C PCE GROUP Europe Im Langel 4 Tel 0049 0 2903 976 99 0 D 59872 Meschede Fax 0049 0 2903 976 99 29 E Mail info warensortiment de Internet www pce group europe com Konformitatserklarung Declaration of conformity for apparatus with CE mark Konformitatserklarung fur Gerate mit CE Zeichen Declaration de conformite pour appareils portant la marque CE Declaracion de conformidad para aparatos con disitintivo CE Dichiarazione di coformita per apparecchi contrassegnati con la marcatura CE PCE LSZ C 1 EN 55022 standard Limits and methods of measurement of radio disturbance characteristics of information technology equipment and IEC 61000 4 3 Electromagnetic compatibility EMC Part 4 3 T
5. cccceccseeccescceecseessnseeseesens 13 14 Special functions description r rere n IEN ANE EEEE nnns nna nnn anna 14 s COC PCRE 15 Ioui Toca eism eaten oA E arta a en E E EE E 15 17 Weighing E 15 18 Paperweight Calculation PAPEL esses sees nana 16 19 Serial port transmission parameters F rS esses seen nnn 18 20 Maintenance and repairs of small defects esee esee 19 Declaration of Conformity ccccscccccseccccsescccsuseccsusessseessssessaeessaesessuesessausessaeeetsesensnaees 20 info tursdaletechnicalservices co uk 1 General description This type of scale PCE LSZ C is mainly used in paper production tissue production paper laboratories textile production companies as well as by material importing companies and in laboratory practice This scale it s perfect for sales departments comparing the paper or fabric weight to the competition when visiting customers For periodical control of the balance the user should own weight standard of OIML E2 class weight value stated in Technical Data sheet available separately All balances are metrologically tested calibration on demand NACE classification 33 20 31 2 Completeness A standard set consist of 1 Balance 2 Pan elements round pan balances PCE LSZ 100C PCE LSZ 600C pan support and pan rectangular pan balances
6. ervice centre should use calibration weight as stated in Technical Data table or of better accuracy with valid calibration certificate Operation sequence ean CPi cid Press V key Press W key several times to choose calibration weight value To accept press 7 button Wait until calibration process is finished When LOAD communicate put a calibration weight on the pan and press gt lt key Wait until internal calibration is finished The display should indicate the weight standard value 12 PCE info tursdaletechnicalservices co uk 13 Connecting the balance to a computer or a printer The balance may send data to a computer or a printer through RS232C port RxD reception TxD send ground When cooperating with the balance a computer should be equipped with a program which enables processing data from the balance PCE Group offers computer programs cooperating with balances Demo versions and program descriptions are available on the website www pce group europe com There is also a freeware program for testing a serial port of the balance casing We also offer e Computer wires e Thermal printers e Label printers The balance sends weighing result after initialising signal from a computer or after pressing E key Data transmission protocol description Long protocol Computer Balance initialising signal S CR LF 53h 49h ODh OAh Balance
7. esting and measurement techniques Hadiated radio frequency electromagnetic field immunity test harmonized with the Council Directive 89 336 EEC Electromagnetic compatibility directive Additional information Conformity evaluation for the Council Directive 89 336 EEC was carried out by Research Laboratory of Electrotechnology Institute Date 01 03 2006 Signature PCE GROUP Europe OHG Management In this direction will find a vision of the measurement technique http www industrial needs com measuring instruments htm NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases 18
8. he load indicator graduated in percentages 4 Weighing result should be read when the indicator lights which signalises stabilisation of a result 5 When the balance is not used but it is necessary to be ready to work immediately it can be switched off by pressing key The balance reading system is then switched off to standby mode signalled by the indicator OFF To switch the balance on press key The balance is immediately ready to operate maximum accuracy after self tests 6 The mechanism of the balance is a precise device sensitive to mechanical strokes and shocks 7 The balance should not be used to weigh ferromagnetic materials due to accuracy decrease Do not overload the balance more then 2096 of maximum load Max Do not press the pan with a hand Before transportation take off the pan move it slightly and lift it up and the pan base and preserve from any damages 11 11 Testing and calibration To ensure reliable results it is advised to check balance accuracy with an object of precisely known weight before and after each measuring session In case permissible error is exceeded calibrate the balance with an external weight standard or contact an authorised service 12 External calibration info tursdaletechnicalservices co uk Calibration with external weight standard should be performed in case balance indications exceed permissible error To calibrate the balance a s
9. ng mode into the conventional balancing mode in g Present them the sample on the weighing platform of the balance The weight of the sample is indicated to the balance at the display 19 Serial port transmission parameters F rS hry The function enables to set the following transmission parameters standard F rS _ 2T parameters underlined v i transmission speed bAud 1200 4800 F O 9600 lt gt the number of bits in a byte bit 7 8 parity control PArItY 0 1 Odd O 1 E 1 gt T lt 4 3 i Continuous transmission without using D key approx 10 results per second Tn SEnd O 1 To set desired transmission parameters activate T T9 function choose appropriate parameter and press 7 lt key to accept needed parameter value The example at the left presents how to set transmission speed value to 9600bps To leave the function choose out option 16 PCE info tursdaletechnicalservices co uk 20 Maintenance and repairs of small defects 1 The balance should be kept clean 2 Take care that no dirt gets between the casing and the pan If found any remove the pan lift it up remove dirt and then replace the pan 3 In case of improper operation caused by short lasting power supply decay unplug the balance from the mains and then plug it again after few seconds 4 To calibrate the balance contact nearest service 5 It is for
10. pan ring 3 and put the pan 1 on the pan support PCE LSZ 600C balances are equipped with a pan integrated with the pan support 5 PCE LSZ 1000C PCE LSZ 4000C only Place the pan supports 2 on the icis at the corners of the casing Place the pan 1 on the pan supports 1 10 info tursdaletechnicalservices co uk 6 Plug a feeder to the power socket at the back of the balance Moisture in the air may condense on the surface of the balance when transferred to the warmer environment In this case leave the balance for at least 4 hours unplugged from the mains for conditioning to avoid wrong operating or damage of the balance 7 Leave the pan empty and plug the feeder to the mains 230V At the end of self tests the balance displays zero indication and is now ready to work 10 General rules 1 Weighed sample should be placed in the centre of the pan 2 In balances with active O lt key and with d e before placing a load on the pan make sure that zero indicator is displayed If not press 0O key and wait until zero indication and zero indicator appears In other balances the key does not operate 3 The balance is equipped with tare equal to its range To tare the balance press gt T lt key left or right Storing tare value does not extend measuring range but only subtracts it from a load placed on the pan To make weight control easier and to avoid range overdrawing the balance is equipped with t
11. properly unplug it from the mains and do not use until checked by authorised service 7 Environment protection According to legal regulations it if forbidden to dispose electronic equipment in waste containers WEEE Reg Nr DE64249495 Please return wasted balance to the point of purchase or other company specialised in recycling of wasted electronic components PCE info tursdaletechnicalservices co uk 8 Working environment When choosing a location to set up the balance remember the following rules to ensure proper working conditions and user friendly operating setup the balance on an even flat surface leaving necessary room for easy access maintain proper working temperature avoid strong air drafts vibrations dust big temperature changes and humidity over 90 avoid locations with extreme heat radiation and electromagnetic or magnetic fields PCE info tursdaletechnicalservices co uk 9 Preparation the balance 1 Take the balance and all supplied accessories a feeder pan elements out of the box 2 Place the balance on a stable ground not affected by mechanical vibrations and airflows 3 Level the balance with rotating rear legs 6 so that the air bubble in water level 7 at the back of the balance is in the middle 4 PCE LSZ 100C PCE LSZ 600C only Gently place the pan support 2 into the socket in the balance mechanism through the
12. with pictures 14 PCE info tursdaletechnicalservices co uk 15 Legend hy press a key balance indication 123 4 g forced change v automatic change NV 16 Normal weighing When the pan is empty and indication is different than zero press gt T lt key Note In balances for direct trade settlements option to zero a balance use 0 lt key gt T key operates as Tare only when the pan is loaded Weighing result should be read when the indicator 2 lights he balance is equipped with tare equal to its range 15 PCE info tursdaletechnicalservices co uk 18 Paperweight calculation PAPEr The paper scale is a high precision resolution device for the determination of the basis weight in relation to a square meter of materials This is the most accurate way to determine basis paper tissue weight The scale displays the basis weight of paper tissue fabrics directly in g m with 0 1 g m 0 001 g resolution This function enables to calculate paperweight of 1m of paper basing on samples of known area Weighing in g m 2 By the pressing of the key one changes for the conventionally weighing between the paper balancing function in g m and in g The paper balancing mode g m by the indication A in the left display corner suggested without that the unit g m at the display is indicated Weighing in g Switch with the help of the key from the paper balanci
13. www pce industrial needs com PCE Deutschland Gmb H amp Co KG Tel 49 029 03 976 99 0 Fax 49 029 03 976 99 29 info warensortiment de www warensortiment de PCE Group Ib rica S L Tel 34 967 543 548 Fax 34 967 543 542 info pce iberica es www pce iberica es PCE Group Italia S R L Tel 39 0583 975 114 Fax 39 0583 974 824 info pce italia it www pce italia it Manual High Resolution Paper scale PCE LSZ PCE info tursdaletechnicalservices co uk Contents r e ieieizciogie Mme Rene ero ee ate nee ee ea eee E A E mn E ee 3 2 Completeness 00 cece cecccssccccececcececcueccseeessseessueessusessseesseeessesensesessneessesessnsesseeessnsesanses 3 3 Balance Geschlossen E E EEE eed eee 4 4 Keys and indicators s eessesssssisssssses esee nennen nnn nn hann nans nane saa n sans n aar sa ansa nnns 6 L LEONCIO t RE 7 MES rr MP 8 7 Environment protection ccccccccccscccesccuecsuensuensucceecsuecsuensuensuesueseessuetsuensuensesanenaness 8 6 000 0098 1117192117 2 P 9 9 Preparation the balance ccccccceccsscccsnecsescceuecsuscseecnsustsuseseuessuetsusesseensnessnsesanes 10 10 General FULCS cece cecccecccsecccsecceeeesneeeseeecsenessseessaeessseeessueessnessaeessseessaeessseesseessnes 11 11 Testing and CANON OU PM P Em 12 TZ SOT CAVA ON X 12 13 Connecting the balance to a computer OF a printer 0 cccc