Home

DMX Switch Pack

image

Contents

1. Table 2 Pin Values pn 112 31 14 516 7 8 9 10 lt S kl ol wl ol S o o S N BR wp a e O N 0 Example Channel 13 Example Channel 67 Set pins 1 3 and 4 ON Set pins 1 2 and 7 ON channel no 13 channel no 67 value of pin 4 8 value of pin 7 64 remainder 5 remainder 3 value of pin 3 4 value of pin 2 ES remainder 1 remainder 1 value of pin 1 1 value of pin 1 1 remainder 0 remainder 0 User Manual 5 Operation Apply power The panel diode lights when power is applied to the DMX Switch Pack Control fixtures Power output 1 is controlled on the first channel power output 2 is controlled on the second channel and so on To turn a fixture on set the channel s DMX value anywhere above 50 percent DMX 128 255 To turn it off set the value anywhere below 50 percent DMX 0 127 Maintenance Replace fuses If the power diode does not light when power is applied the main fuse may be blown The main fuse is found in a holder next to the power cord it can be replaced without opening the cover Each power output is fused as well If one channel does not function properly the power output fuse may be blown The cover must be removed from the unit to access these fuses Always disconnect the switch pack from electricity before servicing If a fuse blows repeatedly there is a malfunction with
2. DMX Switch Pack user manual 1998 2006 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printed in Denmark P N 35000010 Rev D Thank you for selecting the Martin DMX Switch Pack This DMX controlled switching device allows you to turn on and off up to six 350 watt devices with the Martin 2518 DMX Controller or any other DMX board It allows you to control non intelligent lights and is ideal for combining fixtures from Martin s DJ Series with intelligent lights The DMX Switch Pack is not suitable for switching products with discharge lamps prod ucts with fluorescent tubes or metal halide lamps The DMX Switch Pack is ruggedly built for years of trouble free use Setup and operation are simple please read this manual before setting up and operating the device Safety information WARNING This product presents risks of lethal or severe injury This product is for professional use only It is not for household use Read this manual before powering or installing the fixture follow the safety precautions listed below and observe all warnings in this manual and printed on the fixture If you have questions about how to operate the fixture safely please contact your Martin dealer or call the Martin 24 hour service hotline at 45 70 200 201 To protect yourself and others from e
3. User Manual 7 we Martin Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Denmark Phone 45 8740 0000 Internet http www martin com
4. either the switch pack or one of the fixtures connected to it that must be referred to a service technician Always replace the fuse with one of the same size and rating 6 DMX Switch Pack Specifications Construction IST TEE steel FEinisha eege eeh qata a Mua d aa E electrostatic powder finish Control Brotogot aaa a as DMX values output power off DMX values output power on Channels yirs eege G E EE EEE EE EE ie Ei 6 eelere E 1 512 R ceiver typen ss y aym Si e ee Ried RS 485 Dimensions Length 250 mm 9 8 in Kal s aan aaa m Qa a auqa aa 150 mm 5 9 in H ighta nn E ect ee hee S C m Rosie E 71 mm 2 8 in Electrical EU version Power SUPPLY sc s cciceccascesetivescescdecescctcasesneavess iii iiaii Maximum total power consumption Maximum power per channel Main RE 10 A 250 V time delay T Output f uSeS a nqa ana asna ana asas 2 A 250 V time delay T Electrical US version Power Supply u t u eee Mla BA 100 130 V 50 60 Hz Maximum total power consumption n ns 2200 W Maximum power per channel sirsie iier s Ee EEE 350 W Main ET 20 A 250 V time delay T RI EE 4 A 250 V time delay T Panel connections Data oe E 3 pin XLR male Data LE 3 pin XLR female Power outputs EU version n nsssssssss 6 x grounded IEC female e Power outputs US version 6 x grounded Edison female
5. lectric shock Disconnect the fixture from AC power before removing or installing fuses or any part and when not in use Always ground earth the fixture electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault protection Do not expose the fixture to rain or moisture Refer all service to a qualified technician Never operate the fixture with missing or damaged covers To protect yourself and others from burns and fire Never use the device to power fixtures that exceed the specified maximum load Never attempt to bypass the fuses Always replace defective fuses with ones of the specified type and rating Do not modify the fixture or install other than genuine Martin parts To protect yourself and others from injury due to falls When suspending the fixture above ground level verify that the structure can hold at least 10 times the weight of all installed devices Secure the device with a safety wire threaded through the side holes Block access below the work area whenever installing or removing the fixture User Manual 3 Setup The DMX Switch Pack comes with a 5 meter shielded 3 pin XLR cable In addition the EU version includes 6 standard male IEC plugs for connecting fixtures The following installation steps are required Install a plug on the power cord Install IEC plugs on the fixtures EU versio
6. n only Connect the data link Set the DMX address PN Install plug The switch pack is delivered with no plug on the power cord Following the manufacturer s instructions install an approved 3 prong grounding type plug that fits your supply Connect the wires to the pins as listed below The table shows some possible pin identification schemes if the pins are not clearly identified or if you have any doubts about proper instal lation consult a qualified electrician Table 1 Plug Wiring Wire EU Wire US Pin Marking Screw US brown black live LU yellow or brass blue white neutral N silver yellow green green ground a green Connect data link Connect the data link cable to the In jack using a 3 pin female XLR connector If using 5 pin cables a 5 pin male to 3 pin female cable such as Martin P N 309160 must be used Pins 4 and 5 are not used Continue the data link by connecting the cable to the Out jack use a 3 pin XLR male connector Insert a termination plug in the Out jack if the switch pack is the last device on the link A termination plug is simply a 3 pin male XLR connector with a 120 ohm resistor soldered between pins 2 and 3 Connect fixtures EU version IEC male plugs included must be installed on the fixture power cords Connect the wires as shown in the above table Consult a qualified electrician if the power cord for your fix tures are colored diffe
7. rently Plug the fixtures into the power outputs Each outlet can deliver up to 350 watts of power DMX Switch Pack DO NOT connect higher wattage devices to the switch pack or connect more than one fix ture to an output DO NOT connect a product with a discharge lamp e g a product with fluorescent tubes or metal halide lamp to the DMX Switch Pack Doing so can cause seri ous damage to both the DMX Switch Pack and the product connected to it Connect fixtures US version Plug the fixtures into the power outputs Each outlet can deliver up to 350 watts of power Do not connect higher wattage devices to the switch pack or connect more than one fixture to an output Set DMX address The DIP switch must be set to the start channel also known as the address which is the first of the six channels the controller uses to send instructions to the switch pack Any channel between 1 and 512 may be selected as long as the last channel 6 is within the con troller s range The 2518 DMX Controller has 72 channels the highest useful start channel is 67 Set the DIP switch by switching ON one or more of the pins until their total value equals the start channel Each ON pin adds the value listed below OFF pins add no value The setting can be found by subtracting pin values starting from the highest value that is less than or equal to the start channel until the total of the values subtracted equals the channel number See the examples below

Download Pdf Manuals

image

Related Search

Related Contents

One Handle Kitchen Faucet  Pavestone RSK50377 Use and Care Manual    OASIS3 User Guide oasis3 3  ORIGINAL MANUSCRIPT.indd    RCA LCDS2022B User's Manual  001. cla402302_manual    Triangle Solo 110 Boiler Manual  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.