Home

Datasheet for Models: range NEW - The Building Product Directory

image

Contents

1. Y Lic No KM524754 BS EN 14604 2005 Kidde Firex 2012 model numbers previous models in brackets Back up type Sealed in Loose rechargeable battery Alarm type lonisation smoke KF1R 4881 KF1 4870 Optical smoke KF2R 4985 KF2 4973 Heat KF3R 4892 KF3 4899 Datasheet for Models KFIR KF1 230V Mains lonisation Smoke Alarms Key Features Firex hard wired smoke and heat alarms all have a full 6 year guarantee and are BSi Kitemarked to reinforce the consistent quality provided by the world s largest manufacturer lonisation and optical models are complemented by heat alarms for situations unsuitable for smoke alarms such as kitchens and garages e Single Hush and Test button e Choice of sealed in rechargeable three Panasonic lithium cells or loose battery back up ranges e Cable harness type connection and interconnectable up to 24 units e Supplied with base plate Applications Both models are mains powered for professional installation with back up power complying with current minimum requirements of the relevant Building Regulations for new housing i e Grade D BS5839 Part 6 lonisation Smoke Alarms are for use where a fast flaming fire for example electrical equipment igniting is more likely to be a hazard than a slow smouldering one such as from furniture and bedding They are more prone to nuisance alarms from cooking particles and steam near kitchens They c
2. Simulates the effect of smoke within the sensing chamber checks electronics and sounder Circuitry is tested and unit single beeps chirps if fault is detected 230V AC 50Hz nominal UK Voltage Typical 50mA Push fit snap in grip type connector with 150mm long flying leads supplied Model KF2 1 off 9 Volt Alkaline Battery 522 6LR61 User replaceable Model KF2R 3 off 3 Volt Rechargeable Lithium Cells Panasonic UL2330 User Non replaceable Models KF2R and KF2 230V Mains Optical Smoke Alarms Continuous green LED showing mains power present Electronic Piezoelectric sounder providing sound three pulses space three pulses in alarm state 850B A minimum at 3m 3 2 kHz typical Red LED flashes approximately once a minute showing normal operation Red LED flashes once a second when sensing smoke sounder alarm sounds RED LED flashes once every ten seconds to indicate in hush condition auto reset after fifteen minutes RED LED off another smoke alarm in an interconnected system has sensed smoke and is signalling an alarm O16 40 C Up to 93 Relative Humidity RH Up to 24 of these units can be interconnected KEIR KF1 KE2R KEZ KESR Ke3 1SFW 1SFWR 2SFW 2SFWR 3SFW 3SFWR Connectable as hard wire interconnected system up to 24 units as interconnect detail above Firex may be connected to Kidde Fyrnetics Slick alarms See user manuals downloadable from www smoke alarms co uk Use with
3. g Kidde Fyrnetics Ly Pig Developed specifically tor social and private housing Slick is the only range of fast fit rechargeable ionisation and optical smoke alarms and heat alarms guaranteed for 10 years All Slick alarms are BSi Kitemarked to reinforce the consistent quality provided by the world s largest manufacturer a f j a Y Lic No KM524754 BS EN 14604 2005 Kidde Poy PRET Fyrmetics Savon ce Residential lanisation Smoke i Alarm Tein Eee 4 ard apuraha bash sml Esi Puliga bpi hiia df iia lt gt aa TSY with Linhines ca 3 Buttery hack ag Datasheet for Models 1SFWR 1SFW 230V Mains Fast Fit lonisation Smoke Alarms 1SFWR with the latest Rechargeable Polymer Lithium cell back up and full 10 year guarantee 1SFW with Duracell loose alkaline battery back up and 6 year guarantee Key Features e Wireless Capability enabling use with Kidde Fyrnetics new Wireless Alarm Base Model RF SFTP for wire free interconnection e Compatible with Kidde Fyrnetics new Remote Test amp Hush switch Model KN RTH RF via the Wireless Alarm Base e Integral double decker screwless terminal block for fast push fit connection e Unique fast Tit system with separate base plate enabling fitting after construction and removal for maintenance e Auto resets after activation with latching LED allowing the initiating alarm to be identifi
4. Bracket has central access hole of 50mm diameter for cabling Plastics used NORYL Cover main body and mounting bracket Dimensions 127mm diameter x 39mm depth including mounting bracket Dimensions Mounting Bracket 133mm diameter 9mm max depth typical Weight KF1 unit out of box 231 grams KF1 unit in single box 269 grams KF1R unit out of box 199 grams KF1R unit in single box 297 grams Guarantee 6 years including the battery on model KF1R BS 5839 Category BS 5839 Part 6 Grade D BS 5839 part 6 Grade C when used with the REMTH unit giving some elements of a central control Specifications are subject to variation by improvement and change Wired Remote Test and Hush Unit g Kidde Fyrnetics Kidde Fyrnetics Mathisen Way Colnbrook Berkshire SL3 OHB T 01753 685148 F 01753 685096 www smoke alarms co uk Kidde reserves the right to alter its products and specifications without notice in line with best practice and continuous improvement Firexlon SS Inp 8 12 The new look cost effective Firex cable harness range of smoke and heat alarms manufactured and supplied by Kidde with the reassurance of a leading global manufacturer Y Lic No KM524754 BS EN 14604 2005 Kidde Firex 2012 model numbers previous models in brackets Back up type Sealed in Loose rechargeable battery Alarm type lonisation smoke KF1R 4881 KF1 4870 Optical smoke KF2R 4985
5. KF2 4973 Heat KF3R 4892 KF3 4899 Datasheet for Models KF2R KF2 230V Mains Optical Smoke Alarms Firex hard wired smoke and heat alarms all have a full 6 year guarantee and are BSi Kitemarked to reinforce the consistent quality provided by the world s largest manufacturer lonisation and optical models are complemented by heat alarms for situations unsuitable for smoke alarms such as kitchens and garages Single Hush and Test button Choice of sealed in rechargeable three Panasonic lithium cells or loose battery back up ranges Cable harness type connection and interconnectable up to 24 units Supplied with base plate Both models are mains powered for professional installation with back up power complying with current minimum requirements of the relevant Building Regulations for new housing i e Grade D BS5839 Part 6 Optical Smoke Alarms are for use in escape and circulation routes and in areas where there is danger of ignition of furniture and surroundings by cigarettes They are best suited to slow smouldering fires such as PVC cabling foam tilled furniture or bedding material They are less prone to nuisance alarms than lonisation alarms from cooking particles and steam near kitchens Optical circular lateral chamber with insect resistant width 9 slot entry inlet portals 35mm outside diameter x 16mm depth approximate external BSi Kitemarked to BS EN 14604 2005 Infrared light wavelength
6. RF Wireless Base Remote Test and Hush Unit when used with the RF SFTP Wireless alarm base Fixing Slick mounting base as supplied deep base Base Cable Connections Screwless Terminal Block with slot release feature for conductors Dimensions 135mm diameter x 89mm depth approximately with Slick mounting base Guarantee 10 years including the battery back up Model 3SFWR 6 years excluding battery Model 3SFW Approvals Kite marked to BS 5446 pt 2 2003 License no KM503753 and CE tested and certified Associated Standards BS 5839 Part 6 Grade D A UTC Fire amp Security Company Kidde Safety Europe Mathisen Way Colnbrook Berkshire SL3 OHB T 01753 685148 F 01753 685096 www smoke alarms co uk Kidde reserves the right to alter its products and specifications without notice in line with best practice and continuous improvement SlickRF SS Inp 61 1 g Kidde Fyrnetics Developed specifically tor social and private housing Slick is the only range of fast fit rechargeable ionisation and optical smoke alarms and heat alarms guaranteed for 10 years All Slick alarms are BSi Kitemarked to reinforce the consistent quality provided by the world s largest manufacturer Integral rechargeable back up Datasheet for Accessory Model RF SFTP panti i aN ON I a _ aah 230V Mains Wireless Alarm Base Technical Specification
7. optional remote control see below REMTH Wired Remote Test and Hush Unit allows test and hush of units interlinked as a system SMK23U allows for surface conduit installations such as retrofit SMK23RU as above but with integral switchable relay for operating remote devices Requires a live mains supply to function SMK23RU relay base with voltage free relay contacts rated at 8A 24VDC 8A 250Vac resistive load relay for signalling switching to of devices other than the smoke or heat alarms 132mm diameter x 20mm depth Mounting bracket ring supplied with two T slot fitting option 57mm spacing to max of 90mm for standard screw fittings on back boxes Bracket has central access hole of 50mm diameter for cabling NORYL Cover main body and mounting bracket 127mm diameter x 39mm depth including mounting bracket 133mm diameter 9mm max depth typical KF2 unit out of box 242 grams KF2 unit in single box 308 grams KF2R unit out of box 210 grams KF2R unit in single box 281 grams 6 years including the battery on model KF2R BS 5839 Part 6 Grade D BS 5839 part 6 Grade C when used with the REMTH unit giving some elements of a central control Specifications are subject to variation by improvement and change Control for Smoke and sing sens one Hush es ot pen nent will Manual reset Locate press sgain Wired Remote Test and Hush Unit Kidde Fyrnetics Mathisen Way Colnbrook Berkshire
8. without notice in line with best practice and continuous improvement PLY PIAS I GIL Developed specifically for social and private housing Slick is the only range of fast fit rechargeable ionisation and optical smoke alarms and heat alarms guaranteed for 10 years All Slick alarms are BSi Kitemarked to reinforce the consistent quality provided by the world s largest manufacturer Y Lic No 503753 BS 5446 Pt 2 2003 Residential Heal Alarm Bi Terie LEB 5 i etd Higie i haak gaj jaut Garton far amid af tiem aya Gard ieee alam Lass Aa Datasheet for Models 3SFWR 3SFW 230V Mains Fast Fit Heat Alarms Wireless Capability enabling use with Kidde Fyrnetics new Wireless Alarm Base Model RF SFTP for wire free interconnection Compatible with Kidde Fyrnetics new Remote Test amp Hush switch Model KN RTH RF via the Wireless Alarm Base Integral double decker screwless terminal block for fast push fit connection Unique fast fit system with separate base plate enabling fitting after construction and removal for maintenance Auto resets after activation with latching LED allowing the initiating alarm to be identified Separate Hush amp Test buttons for ease of use Green amp Red LED s to indicate alarm status Interlinkable with Slick or Firex hard wired smoke amp heat alarms Can be added to existing Slick or Firex installations Interlinkable with Kid
9. 117 grams Guarantee 5 years including the battery back up from date of purchase Approvals CE compliancy EMC directive 89 336 EEC R amp TTE Directive 99 5 EC ETSI EN 301 489 1 V1 8 1 2008 04 ETSI EN 301 489 3 V1 4 1 ETSI EN 300 220 1 V2 3 1 2009 04 ETSI EN 300 220 2 V2 3 1 2006 04 2002 08 EN 55022 2006 EN 61000 3 2 2006 EN 61000 3 3 2005 Associated Standards BS 5839 Part 6 Grade D accessory to be used with smoke and heat alarms with the appropriate bases Provides an element of some central control as Grade C DB A a Kidde A UTC Fire amp Security Company Kidde Safety Europe Mathisen Way Colnbrook Berkshire SL3 OHB T 01753 685148 F 01753 685096 www smoke alarms co uk SlickSS RTH 7 11 Kidde reserves the right to alter its products and specifications without notice in line with best practice and continuous improvement Datasheet for Models WB 423D 9HIR g Kidde Ben Developed for professional hard with digital display and Peak Level feature wired installation the ICO range is mains powered with integral rechargeable lithium battery backup and fully guaranteed for 6 years All Kidde CO alarms are BSi Kitemarked to reinforce the consistent quality provided by the world s largest manufacturer non digital model Mains powered with sealed in rechargeable lithium cells for back up preventing tenant access Product life
10. F is designed for up to 15 Wireless Alarm Base units to be used with one RTH test and hush switch within a single system although this can be varied It is guaranteed for five years and has a power saving feature which locks out after 36 seconds when continuous button depression occurs to avoid accidental drain in transmission A four second delay response to button depression assists in battery lifespan achievement The KN RTH RF has raised symbols below the buttons to assist with button identification in poor light situations An RTH unit can be utilised with a wireless alarm base to allow existing Kidde Slick smoke and heat alarms to provide a wireless test hush solution Operational Characteristics e When the Test button is pressed on the KN RTH RF it transmits a test alarm activation signal using the 868MHz frequency range This causes the enrolled wireless alarm base to signal and causes that unit and other interconnected smoke or heat alarm units to enter alarm state operating as a system via the MASTER Wireless Alarm Base When the triggering unit ceases alarm state the attached units in the system go back into standby state e When the Hush button Is pressed on the KN RTH RF it transmits a hush alarm activation signal using the 868MHz frequency range This causes the enrolled wireless alarm base to signal and causes that unit or the other smoke or heat alarm units to come out of alarm state operating as a system via
11. SL3 OHB T 01753 685148 F 01753 685096 www smoke alarms co uk Kidde reserves the right to alter its products and specifications without notice in line with best practice and continuous improvement FirexOpt SS Inp 812 Datasheet for Models BA g Kidde RA Firex ig The new look cost effective Firex cable harness range of smoke and 230V Mains Heat Alarms heat alarms manufactured and supplied by Kidde with the reassurance of a leading global manufacturer Key Features Firex hard wired smoke and heat alarms all have a full 6 year guarantee and are BSi Kitemarked to reinforce the consistent quality provided by the world s largest manufacturer Single Hush and Test button Choice of sealed in rechargeable three Panasonic lithium cells or loose battery back up ranges Supplied with base plate Applications Both models are mains powered for professional installation with back up k gt a power complying with current minimum requirements of the relevant Building Regulations for new housing i e Grade D BS5839 Part 6 Heat Alarms are for use in humid or dusty environments where smoke alarms will not operate satisfactorily such as kitchens boiler rooms unconverted attics and garages a aN cy i J They are triggered when the ambient temperature reaches 57 C and must always be interconnected with smoke alarms from the same product range
12. a d as i d La Technical Specification Sensor Thermistor Thermal resistor within detection unit 4 i a Certification BSi Kitemarked to BS 5446 Pt 2 2003 as a Class A2 device i Button Test Simulates the effect of heat at the sensor checks electronics and Lic No 503753 sounder BS 5446 Pt 2 2003 Automatic Self Test Circuitry is tested and unit single beeps chirps if fault is detected Supply Voltage 230V AC 50Hz nominal UK Voltage Power Consumption Typical 50MA Kidde Firex 2012 model numbers a previous models in brackets Connection Push fit snap in grip type connector with 150mm long flying leads l supplied Back up type Sealed in Loose rechargeable battery Battery back up Model KF3 1 off 9 Volt Alkaline Battery 522 6LR61 Alarm type User Replaceable lonisation smoke KF1R 4881 KF1 4870 Model KF3R 3 off 3 Volt Rechargeable Lithium Cells Panasonic UL2330 Optical smoke KF2R 4985 KF2 4973 User Non replaceable Heat KF3R 4892 KF3 4899 Power On Indicator Continuous green LED showing mains power present Models KF3R and KF3 230V Mains Heat Alarms Technical Specification cont 57 Alarm Electronic Piezoelectric sounder providing sound three pulses 4 space three pulses in alarm state i 9 2 an gt Alarm Sound Output 85dB A minimum at 3m Sreem Alarm Frequency 3 2 kHz typical ww measa Alarm Status Red LED flashes approximately once a minute showing n
13. ated by an on off switch The alarm shall comply with BS EN 50291 2001 and be BSi Kitemarked Both alarm and integral rechargeable battery to be fully guaranteed for 6 years The alarm shall have the manufacturer s own electrochemical sensor with de ionised water electrolyte sampling the environment for CO once every 15 seconds The alarm shall have a tamper resisting self locking installation system with base plate supplied The alarm to be capable of interconnection to other compatible Kidde hard wired smoke heat and CO alarms without any need for a special accessory between them The alarm shall incorporate the Smart Interconnect feature that allows it to resoond to a smoke heat incident when interconnected with compatible Kidde smoke or heat alarms The alarm to be capable of wall or ceiling mounting using a surface mounted pattress Kidde part SMK23 In new build a dry lining box may be used with pegs to fix down the terminal block Kidde Safety Europe Mathisen Way Colnbrook Berkshire SL3 OHB T 01753 766144 F 01753 685096 www TenYCO kiddefyrnetics co uk Kidde reserves the right to alter its products and specifications without notice in line with best practice and continuous improvement ICO SSAnp 212 g Kidde Firex The new look cost effective Firex cable harness range of smoke and heat alarms manufactured and supplied by Kidde with the reassurance of a leading global manufacturer Kidde Firex
14. back up power complying with current minimum requirements of the relevant Building Regulations for new housing i e Grade D BS5839 Part 6 Optical Smoke Alarms are for use in escape and circulation routes and in areas where there is danger of ignition of furniture and surroundings by cigarettes They are best suited to slow smouldering fires such as PVC cabling foam filled furniture or bedding material They are less prone to nuisance alarms than lonisation alarms from cooking particles and steam near kitchens a wireless capability Models 2SFWR and 2SFW 230V Mains Fast Fit Optical Smoke Alarms Optical chamber with insect resistant width slot entry inlet portals 41mm outside diameter x 16mm approximate depth external Complies with BS EN 14604 2005 Infrared light wavelength Simulates the effect of smoke within the sensing chamber checks electronics and sounder Circuitry is tested every 40 seconds and unit beeps if fault is detected 230V AC 50Hz nominal UK Voltage Maximum 80mA Four in built Lithium rechargeable cells Model 2SFWR User replaceable Alkaline Battery 9 Volt MxX1604 Model 2SFW Battery is monitored and unit emits a single chirp beep every 40 seconds if a fault is present Continuous green LED Electronic Piezoelectric sounder providing sound three pulses space three pulses in alarm state 850B A minimum at 3m 3 2 kHz typical Red LED flashes rapidly indicating unit sen
15. de hard wired CO alarms using Smart Interconnect technology Up to 6 months continuous operation from back up cells in the event of mains failure 30 days low battery warning indicator Both models are mains powered for professional installation with back up power complying with current minimum requirements of the relevant Building Regulations for new housing i e Grade D BS5839 Part 6 Heat Alarms are for use in humid or dusty environments where smoke alarms will not operate satisfactorily such as kitchens boiler rooms unconverted attics and garages They are triggered when the ambient temperature reaches 57 C and must always be interconnected with smoke alarms from the same product range Models 3SFWR and 3SFW 230V Mains Fast Fit Heat Alarms Technical Specification Sensor Thermistor Thermal resistor within detection unit Sensitivity Complies with BS 5446 Pt 2 2003 as a Class A2 device it will alarm at between 54 C and 70 C Button Test Simulates the effect of heat at the sensor checks electronics and sounder Automatic Self Test Circuitry is tested every 40 seconds and unit beeps if fault is detected Supply Voltage 230V AC 50Hz nominal UK Voltage Power Consumption Maximum 80mA Battery back up In built Lithium Polymer rechargeable Battery Model 3SFWR User replaceable Alkaline Battery 9 Volt MX1604 Model 3SFW Battery Monitoring Battery is monit
16. ed e Separate Hush amp Test buttons for ease of use e Green amp Red LED s to indicate alarm status e Interlinkable with Slick or Firex hard wired smoke amp heat alarms e Can be added to existing Slick or Firex installations e Interlinkable with Kidde hard wired CO alarms using Smart Interconnect technology e Up to 6 months continuous operation trom back up cells in the event of mains failure e 30 days low battery warning indicator Applications Both models are mains powered for professional installation with back up power complying with current minimum requirements of the relevant Building Regulations for new housing i e Grade D BS5839 Part 6 lonisation Smoke Alarms are for use where a fast flaming Tire for example electrical equipment igniting is more likely to be a hazard than a slow smouldering one such as dining and living rooms They are more prone to nuisance alarms from cooking particles and steam near kitchens They contain a very small amount of Americium 241 radioactive material which may be a consideration for storage and disposal Ors wireless capability Models 1SFWR and 1SFW 230V Mains Fast Fit lonisation Smoke Alarms Technical Specification Sensor lonisation metallic chamber with 24 number slot entry inlet portals Sensitivity Complies with BS EN 14604 2005 Source Americium 241 0 9 microcurie Button Test Simulates the effect of smoke within the
17. l Developed specifically tor social 10 year guarantee and private housing Slick is the only range of fast fit rechargeable ionisation and optical smoke alarms 2SFW with Duracell loose alkaline battery back up and and heat alarms guaranteed for 10 years All Slick alarms are BSi Kitemarked to reinforce the consistent quality provided by the world s largest manufacturer 6 year guarantee Wireless Capability enabling use with Kidde Fyrnetics new Wireless Alarm Base Model RF SFTP for wire free interconnection Compatible with Kidde Fyrnetics new Remote Test amp Hush switch Model KN RTH RF via the Wireless Alarm Base Integral double decker screwless terminal block for fast push fit connection Unique fast fit system with separate base plate enabling fitting after construction and removal for maintenance Auto resets after activation Separate Hush amp Test buttons for ease of use Green amp Red LED s to indicate alarm status Interlinkable with Slick or Firex hard wired smoke amp heat alarms Can be added to existing Slick or Firex installations Interlinkable with Kidde hard wired CO alarms using Smart Interconnect technology Up to 6 months continuous operation from back up cells in the event of mains failure 30 days low battery warning indicator Y Lic No KM524754 BS EN 14604 2005 Both models are mains powered for professional installation with
18. netics hard wired smoke heat and CO alarms using Smart Interconnect MODEL 42a Y BS EN 50291 2001 Licence No KM98848 Models 423D 9HIR and 423 9HIR 230V Mains Carbon Monoxide Alarms Sensor Electrochemical with de ionised water electrolyte sampling once every 15 seconds Manufactured by Kidde Temperature Battery Temperature Range 4 C to 38 C Humidity Operating range 5 95 RH Audible Alarm 85 dB at 3 metre Power 230V AC 50Hz 30mMA max per alarm Wiring To be in accordance with the latest IEE Regulations BS7671 via a supplied cable harness Back up 8 2V integral rechargeable lithium battery Test Reset Button Yes Peak Level Memory Yes on Model 423D 9HIR Alarm Response Times 30 PPM no alarm within 120 minutes 50 PPM must alarm within 60 90 minutes 100 PPM must alarm within 10 40 minutes 300 PPM must alarm within 3 minutes Dimensions Alarm diameter 147mm x depth 42mm Base diameter 144mm Weight 350g Guarantee 6 years Approvals Kitemarked to BS EN 50291 2001 Licence no KM98848 Replacement 7 years after commissioning Accessories The SMK23 Surface Pattress can be used if necessary ICO mains powered Carbon Monoxide Alarm of circular design model 423D 9HIR with digital display or non digital model 423 9HIR manufactured by Kidde Fyrnetics The alarm to have a sealed in rechargeable lithium back up power supply and be activ
19. of 7 years from initial power up and full guarantee for 6 years Kidde s own CO sensors have unrivalled long term testing regime demonstrating excellent stability over time with third party validation CO cells use safer and environmentally friendly de ionised water electrolyte Checks the environment for CO once every 15 seconds i FA y ER a Neat circular design ICO for ceiling or wall mounting quickly connected with ss a snap on harness and locking into place by default for tamper resistance Separate easy to follow user and installer manuals included and also available on our website Unique Smart Interconnect allowing ICO alarms to interlink with Kidde Fyrnetics Slick hard wired smoke and heat alarms on one wiring network MODEL 4290 9 Digital display model indicates Fire if triggered by interconnected smoke heat alarm or CO if triggered by interconnected CO alarm Digital display model provides early warning of intermittent and low levels of carbon monoxide with Peak Level button to help identity CO problems when the property is unoccupied Kidde Fyrnetics ICO hard wired carbon monoxide alarms are ideal for new build major refurbishment of existing properties or complete re wiring They can be ceiling or wall mounted either in rooms where a potential source of CO is present or where occupants spend most time In bedrooms they can alert sleeping occupants of fire as well as CO when linked to Kidde Fyr
20. ontain a very small amount of Americium 241 radioactive material which may be a consideration for future disposal Technical Specification Sensor lonisation circular metallic chamber with 24 slot entry inlet portals Certification BSi Kitemarked to BS EN 14604 2005 Source Americium 241 s1 0 microcurie 37kBq Button Test Simulates the effect of smoke within the sensing chamber checks electronics and sounder Automatic Self Test Circuitry is tested and unit single beeps chirps if fault is detected Supply Voltage Power Consumption 230V AC 50Hz nominal UK Voltage Typical 50mA Connection Push fit snap in grip type connector with 150mm long flying leads supplied Battery back up Model KF1 1 off 9 Volt Alkaline Battery 522 6LR61 User Replaceable Model KF1R 3 off 3 Volt Rechargeable Lithium Cells Panasonic UL2330 User Non replaceable AN Amnn Models KF1R and KF1 230V Mains lonisation Smoke Alarms Technical Specification cont Power On Indicator Continuous green LED showing mains power present Alarm Electronic Piezoelectric sounder providing sound three pulses space three pulses in alarm state Alarm Sound Output 85dB A minimum at 3m Alarm Frequency 3 2 kHz typical Alarm Status Red LED flashes approximately once a minute showing normal operation Red LED flashes once a second when sensing smoke s
21. ored and unit emits a single chirp beep every 40 seconds if a fault is present Power On Indicator Continuous green LED Alarm Electronic Piezoelectric sounder providing sound three pulses space three pulses in alarm state Alarm Sound Output 85dB A minimum at 3m Alarm Frequency 3 2 kHz typical Alarm Status Red LED flashes rapidly indicating unit sensing fire event rate typically once every two three seconds Red LED double flashes every 30 seconds to indicate the unit is the triggering unit LED latches until test button pressed Red LED flashes once every ten seconds to indicate in hush condition auto reset after seven minutes Normal Operating Temperature Range O to 40 C Humidity Range Up to 93 Relative Humidity RH Interconnect Up to 24 of these units can be interconnected 1 SFW 1SFWR 2SFW 2SFWR smoke alarms 3SFW 3SFWR heat alarms 423 9HIR 423D 9HIR CO alarm hard wire non Slick base relay base See user manuals downloadable from www smoke alarms co uk Interconnect Options Wireless Compatible Using appropriate Wireless Base Connectable via Wireless Base Model RF SFTP up to 15 units Connectable as hardwire with SMART interconnect system up to 24 units as interconnect detail above See user manuals downloadable from www smoke alarms co uk Use with optional control see below Optional Controls With the KN RTH
22. ormal operation Wired Remote Test and Hush Unit Red LED flashes once a second when sensing heat in excess of 58 C sounder alarm sounds RED LED off another smoke heat alarm in an interconnected system has sensed smoke and is signalling an alarm Normal Operating Temperature Range O to 40 C Humidity Range Up to 93 Relative Humidity RH Interconnect Up to 24 of these units can be interconnected KAIR 1 REZR KR KRSR RFS TSAN TORNAR 2S PAN ZFR PAN Son NIN Interconnect Options Connectable as hard wire interconnected system up to 24 units as interconnect detail above Note Firex may be connected to Kidde Fyrnetics Slick alarms See user manuals downloadable from www smoke alarms co uk Use with optional remote control see below Optional Controls REMTH Wired Remote Test and Hush Unit allows test and hush of units interlinked as a system SMK23RU as above but with integral switchable relay for operating remote devices Requires a live mains supply to function SMK23RU relay base with voltage free relay contacts rated at 8A 24VDC 8A 250Vac resistive load relay for signalling switching to of devices other than the smoke or heat alarms SS f JA 132mm diameter x 20mm depth P OE TEE e a EO SMK GONS or sarace CONGUIT INslallallons Uc as Eroii i Fixing Mounting bracket ring supplied with two T slot fitting option y ee 57mm spacing to max of 90mm for standard screw fitting
23. ounder alarm sounds RED LED flashes once every ten seconds to indicate in hush condition auto reset after fifteen minutes RED LED off another smoke alarm in an interconnected system has sensed smoke and is signalling an alarm Normal Operating Temperature Range 0 to 40 C Humidity Range Up to 93 Relative Humidity RH Interconnect Up to 24 of these units can be interconnected SN ENE GZ ReNE2Z Nike NES SEV TSEVVR STW PRSP SRNR Interconnect Options Connectable as hard wire interconnected system up to 24 units as interconnect detail above Note Firex may be connected to Kidde Fyrnetics Slick alarms See user manuals downloadable from www smoke alarms co uk Use with optional remote control see below Optional Controls REMTH Wired Remote Test and Hush Unit allows test and hush of units interlinked as a system Optional Surface Pattresses SMK23U allows for surface conduit installations such as retrofit SMK23RU as above but with integral switchable relay for operating remote devices Requires a live mains supply to function SMK23RU relay base with voltage free relay contacts rated at 8A 24VDC 8A 250Vac resistive load relay for signalling switching to of devices other than the smoke or heat alarms 132mm diameter x 20mm depth Fixing Mounting bracket ring supplied with two T slot fitting option 57mm spacing to max of 90mm for standard screw fittings on back boxes
24. pim See g Kidde A UTC Fire amp Security Company Kidde Safety Europe Mathisen Way Colnbrook Berkshire SL3 OHB T 01753 685148 F 01753 685096 www smoke alarms co uk SlickSS SFTP 7 11 Kidde reserves the right to alter its products and specifications without notice in line with best practice and continuous improvemen t A g Kidde Fyrnetics NEW KH range Developed specifically tor social and private housing Slick is the only range of fast fit rechargeable ionisation and optical smoke alarms and heat alarms guaranteed for 10 years All Slick alarms are BSi Kitemarked to reinforce the consistent quality provided by the world s largest manufacturer Datasheet for Accessory Model Portable Remote Test amp Hush switch powered by integral lithium battery for use with NEW Slick Wireless Capability smoke and heat alarms via Key Features The Remote Test amp Hush switch is simply wireless linked to a NEW Slick Wireless Alarm Base and can be used to test that alarm It can also be used to silence the linked alarm or all but the initiating interconnected alarms The KN RTH RF has a non replaceable lithium battery designed to serve the unit s full lifespan of ten years It features an easy enrol procedure to wirelessly connect it to a suitable wireless alarm base and this can be changed to suit the application position of the alarm The KN RTH R
25. s on back boxes Bracket has central access hole of 50mm diameter for cabling Plastics used NORYL Cover main body and mounting bracket Dimensions 127mm diameter x 39mm depth including mounting bracket Dimensions Mounting Bracket 133mm diameter 9mm max depth typical Weight KF3 unit out of box 213 grams KF3 unit in single box 308 grams KF3R unit out of box 180 grams KF3R unit in single box 279 grams CETELE 6 years including the battery on model KF3R ot BS 5839 Category BS 5839 Part 6 Grade D BS 5839 part 6 Grade C when used with the REMTH unit giving some elements of a central control AA Specifications are subject to variation by improvement and change Kidde Fyrnetics Kidde Fyrnetics Mathisen Way Colnbrook Berkshire SL3 OHB T 01753 685148 F 01753 685096 www smoke alarms co uk FirexHA SS Inp 812 Kidde reserves the right to alter its products and specifications without notice in line with best practice and continuous improvement
26. sensing chamber checks electronics and sounder Automatic Self Test Circuitry is tested every 40 seconds and unit beeps if fault is detected Supply Voltage 230V AC 50Hz nominal UK Voltage Power Consumption Maximum 80mA Battery back up In built Lithium Polymer rechargeable Battery Model 1SFWR User replaceable Alkaline Battery 9 Volt MX1604 Model 1SFW Battery Monitoring Battery is monitored and unit emits a single chirp beep every 40 seconds if a fault is present Power On Indicator Continuous green LED Alarm Electronic Piezoelectric sounder providing sound three pulses space three pulses in alarm state Alarm Sound Output 850B A minimum at 3m Alarm Frequency 3 2 kHz typical Alarm Status Red LED flashes rapidly indicating unit sensing fire event rate typically onceevery two three seconds Red LED double flashes every 30 seconds to indicate the unit is the triggering unit LED latches until test button pressed Red LED flashes once every ten seconds to indicate in hush condition auto reset after seven minutes Normal Operating Temperature Range 0 to 40 C Humidity Range Up to 93 Relative Humidity RH Interconnect Up to 24 of these units can be interconnected 1 SFW 1SFWR 2SFW 2SFWR smoke alarms 3SFW 3SFWR heat alarms 423 9HIR 423D 9HIR CO alarm hard wire non Slick base relay base Interconnect Op
27. sing fire event rate typically once every two three seconds Red LED flashes once every ten seconds to indicate in hush condition auto reset after seven minutes Oto 40 C Up to 93 Relative Humidity RH Up to 24 of these units can be interconnected 1 SFW 1SFWR 2SFW 2SFWR smoke alarms 3SFW 3SFWR heat alarms 423 9HIR 423D 9HIR CO alarm hard wire non Slick base relay base Wireless Compatible Using appropriate Wireless Base Connectable via Wireless Base Model RF SFTP up to 15 units Connectable as hardwire as SMART interconnect system up to 24 units as interconnect detail above See user manuals downloadable from www smoke alarms co uk Use with optional control see below With the KN RTH RF Wireless Base Remote Test and Hush Unit when used with the RF SFTP Wireless alarm base Slick mounting base as supplied deep base Screwless Terminal Block with slot release feature for conductors 135mm diameter x 60mm depth with Slick mounting base 10 years including the battery back up Model 2SFWR Kidde 6 years excluding battery Model 2SFW A UTC Fire amp Security Company Kitemarked to BSEN 14604 2005 Kidde Safety Europe Licence no KM524754 and CE tested and certified Mathisen Way Colnbrook Berkshire SL3 OHB BS 5839 Part 6 Grade D T 01753 685148 F 01753 685096 www smoke alarms co uk SlickRF SS Inp 61 1 Kidde reserves the right to alter its products and specifications
28. the MASTER Wireless Alarm Base In other words the alarm linked to the KN RTH RF will silence OR all but the initiating alarm will silence e The KN RTH RF unit has a visual LED light providing visual operating confirmation when the buttons are pressed e The RTH is light and portable can be used on a table top or fixed to a suitable wall using the separate mounting bracket and screws provided It can easily be removed from and replaced onto the mounting bracket shown on left adding to its simplicity Portable Remote Test amp Hush switch Technical Specification Supply Battery inbuilt Power Consumption Lifespan rated at ten years based on normal operation Battery Lithium battery with ten year life Operation Indicator LED flash on button depression showing transmission Alarm Frequency 868 MHz Wireless Range Up to 10 metres Unit Operation See user manual for further details Normal Operating Temperature Range 0 to 40 C Humidity Range Up to 95 Relative Humidity for base alarms are up to 93 RH Colour White Optional Controls Test Button Non Latching Hush Button Non Latching Fixing Screws and wall ceiling plugs provided with mounting bracket Bracket Hole Spacing Two holes in line spacing 36mm approximately Dimensions 89mm x 89mm x 34mm depth Weight Single unit in box 141 grams Single unit out of box
29. tions Wireless Compatible Using appropriate Wireless Base Connectable via Wireless Base Model RF SFTP up to 15 units Connectable as hardwire with SMART interconnect system up to 24 units as interconnect detail above See user manuals downloadable from www smoke alarms co uk Use with optional control see below Optional Controls With the KN RTH RF Wireless Base Remote Test and Hush Unit when used with the RF SFTP Wireless alarm base Fixing Slick mounting base as supplied deep base Base Cable Connections Screwless Terminal Block with slot release feature for conductors Dimensions 135mm diameter x 60mm depth with Slick mounting base Guarantee 10 years including the battery back up Model 1SFWR 6 years excluding battery Model 1SFW Approvals Kitemarked to BSEN 14604 2005 License no KM524754 and CE tested and certified Associated Standards BS 5839 Part 6 Grade D Kidde A UTC Fire amp Security Company Kidde Safety Europe Mathisen Way Colnbrook Berkshire SL3 OHB T 01753 685148 F 01753 685096 www smoke alarms co uk Kidde reserves the right to alter its products and specifications without notice in line with best practice and continuous improvement SlickRF SS Inp 61 1 Datasheet for Models g Kidde 2SFWR Fyrnetic if P27 JAE 230V Mains Fast Fit Optical Smoke Alarms 2SFWR with rechargeable Lithium cell back up and ful