1.             Copy to clipboard    Fit to window  Set maximal enlargment  Zoom in    Zoom out    Print all images       Print images       Fit ellipse automatically       Turn GDV image upside down          Mirror GDV image horizontally       Save colored images          Compute average image       Capture GDV  View                Menu item Operation   Copy to clipboard Copies the frame  being in the screen  to the clipboard  taking into  account coloring  sectors and viewing   Fit to window Fits maximal quantity of GDV images in the screen simultaneously  the  quantity of images in the screen depends on the monitor resolution    Set maximal enlargement Scales up the selected GDV image for the whole window   Zoom in Scales up the selected GDV image image   Zoom out Scales down the selected GDV image image   Print all images    Calls the Preview window   Print image Calls the Print preview window and prints out the selected GDV  image   Fit ellipse The program automatically recalculate inscribed ellipse overriding   automatically previously made manual changes for single GDV image or for all loaded  GDV images   Turn GDV images Rotates GDV image on 180      upside down       Mirror GDV image  horizontally       Save colored images    Compute average image    View    The image is a rectangular matrix of points of the form I  x  y  with size  w by h  Mirror GDV image horizontally     means to transform the image  so that I  x  y  will take the position I  wx  y     Save GDV images
2.      The subject   s personal data and the GDV images file list are saved in the file with the  sbj extension  The file is  created on the disk  and its content is updated at the moment when you finish working with the program  Inside   the file contains references to the files with GDV images  That is  to transfer the information onto another  computer you need to copy the required  sbj files together with the appropriate files with GDV images keeping  their arrangement with reference to each other in the directory structure     For the convenience of the data storage and transfer to other computers  it is recommended to keep a certain  structure of subject data folders on the disk  In particular  the following example  schematically displayed  is very  convenient  In this case to transfer the information about  e g  Adam Smith you need just to copy the folder Adam  Smith with all its contents and the file Adam Smith sbj  If there is no need to transfer the GDV images you can    just copy the  sbj file  In such case the program will enable you to preview the previously calculated data but re   processing will be inaccessible              My  computer 2010 01 20  2010 03 12   stadium  D Calibration 2010 03 16   office Without filter  Capture1  2010 02 19 With filter   GDV Adam Smith  GDV images    Capture      Data 2010 03 14       Investigations 1 Adam Smith sbj   Sport teams     Bob Marley  GDV images     Bob Marley sbj    Investigations 2   materials                 When y
3.    Close the program                Print GDV mages    Capture GDV mages    Load GDV mages                The   Programs   button makes it possible to start any program from the GDV Software package installed on the  computer  When the selected program is launched the files of subjects open in the current programs are  automatically loaded into it  Further on during work there will be automatic synchronizing of the altered data  among all programs to where the altered subject   s file is loaded        Pinte    Tport       GDV Diagram  GDV Energy Fie    Add new subject entry or  load data from disk    New subject Load subject Load per list Remove from list       GDV capture data is not added                GDV Sport  gt  Working with program  gt  General description of the program    GDV Sport  gt  Working with program  gt  Adding an entry of a new subject data       Adding an entry of a new subject data       On page Subject list there are two lists  the upper one is responsible for the information about subjects and the  lower one for the information about captures assigned to each of subjects loaded into the upper list     To work with the program it is necessary to add the information about a new subject into the upper list  press the    button  highlighted with the color in the figure      r            Omaa K pert    Add new subject entry or  load data from disk       Load subject Load per list Remove from list       GDV capture data is not added          Calibration     
4.   2011_03_13 16 06 MonTueWedthu Fri  A J J Jij2f3    Gerd cason  fats  e 7 e  9  ao  SI   11  12 BEM 14  15  16  17   EER  a8 19  20  21  22  23  24      25  26   27   28  29   30   31  S  GDV images without filter    i           Hi      No data  es Load GDV images  GDV images with filter  No data     Capture GDV images                   Cancel Done    In the lower part of the window there are the control elements that enable to add GDV captures for the given  subject  By default  it will be named Capture 1  If necessary  you can enter the name corresponding to the  specific character of the test  e g  before and after treatment               Right from this window  using button   Load GD images    you can indicated the path to the GDV images with or  without filter if the images have already been captured before and saved to disk  Besides  you can start the GDV  Capture program to capture GDV images by button   Capture GDV images    The line Date is filled out  automatically after loading or capturing GDV images  Enter additional information about capturing in the field  Remark                              Capt  count Remark  1    e  3a                Category       E    GDV capture Date Without filter With filter  2011_03_13 16    4 3 2009 10 46 59 AM is loaded is loadec          4                          Calibration          When you finish entering data press  subject and the newly added capture     Add opire    at dat                    Done      and on page Subject Lis
5.   GDV Sport  gt  Working with program  gt  Pseudocoloring modes       Pseudocoloring modes       You    can view GDV images in various pseudocoloring modes  which enables to study the peculiarity of development    of gas discharge more accurately  Pseudocoloring is only represented in the programs of GDV Software complex   All GDV images are saved on the disc in original palette of 256 tints of grey  You can switch one pseudocoloring  mode to another in the upper left corner of the page        r       The    1     Original image eR  Inverted image K   GDV images with fiter  Intensive palette   Solid palette   Blue tte       Omaa Cport        3K  Moise    Smith   2011_03_13 16 25             Calibration    S N ose Load GDV mages    Calculate    following types of pseudo coloring are provided in the program     Original image   image as it was obtained from video camera and saved in AVI file  Gray color palette  containing 256 shades of gray  from black to white  is used     Inverted image   inverted gray color palette is used  containing 256 shades of gray  from black to white    Particular small details and thin streamers are better seen in this palette than in the initial image     Intensive palette   image points are colored in one of eight colors  The brightest glow points are colored  in the shades of blue  less bright points are colored in the shades of red  Points  the intensity of which is  higher than the noise level  but lower than the base noise level for the given 
6.  a dialog containing consecutively switched pages  Part of pages is  available only after loading or processing of data  The program interface is designed in such a way that the user  can consecutively realize construction and visualization of GDV Sport in accordance with standard analysis  procedure     When the program is launched the start page is displayed from where the user can start working        Start work    User manual    About program          When you select the   User Manual   button  you will see the description of working with programs        The menu item   About program   will display the data on the installed program version  time and date of its issue   the hardlock number  and there is also a possibility to change the language of the user interface to any of the  supported ones without re installing the program  To do this you need to check the required language and restart  the program  The interface language will change for all programs in the package           When you select             JO w    GDV Sport  Version  1 3 8  Build date and time  3 28 2012 3 02 21 AM  Copyright  c  Kirlionics Technologies International    User s interface language  English Change       This program developed using following libraries   wxWidgets 2 8 10  Boost 1 47 0       Start work  click the left mouse button to go to the next page Subject list        Pinte    Tport    Add new subject entry or  load data from disk    New subject Load subject Load per list Remove from lis
7.  in the form of their display on the screen  taking into  account current coloring type  sector fragmentation  etc      Processes averaged image and asks to save it    Calls GDV image real size view window    GDV Sport  gt  Working with program  gt  GDV Image menu       GDV Sport  gt  Working with program  gt  Data table       Data table       The Data table page contains brief numeric information on basic parameters calculated in the GDV Sport  program  These data are presented in the Rating table     The Rating table consists of lines with parameters calculated for each subject and columns containing the following    information    1  N   the ordinal number of the table line    2  NAME   first name  Middle name and Last name of the subject    3  Point   its meaning is from minimum 1 to maximum 10  It characterizes the overall condition  Is has a  direct relationship with the parameter Energy Potential    4  Energy potential  EP    the parameter characterizing the relationship of the physiological and emotional  state of the athlete  It is calculated as a percentage  maximum 100   EP is the characteristics of the  subject   s functional energy level for the period of study  The higher EP  the higher the potential reserve of  the subject  or the competitive readiness level for athletes  High EP value characterizes purposefulness   stress resistance  high movement activity and a stock of potential reserves    5  Stress background  SB    the parameter characterizing the level o
8.  the level of noise for each GDV image frame individually  Base intensity is  calculated on the basis of the analysis of histogram of image spectrum  Statistical characteristics of spectrum are taken as the  values of base intensity  These characteristics correspond to the spectrum average value plus the value of its RMS  average  value of spectrum  median of spectrum or peak of spectrum       Minimal fragment area   removal of fragments of glow with the glow area less than the given minimal area of fragment  On    default this parameter is 30     Working radius   removal of all points of the image whose distance from which to the glow center is bigger than the given  working radius  The glow center is either calculated automatically  as the center of gravity of all the glow points  or set by the  user after manual correction of the glow center  The same value of coordinates of the glow center is used for all the frames of  video file     Intensity correction   the intensity of all pixels of a GDV image increases or decreases by the same value that is  automatically calculated by the program  so as to bring the characteristics of the image spectrum most closely to the  characteristics of the spectrum of test object GDV images taken during calibration              OK   to activate new parameters  The loaded GDV images are automatically filtered from noise under new parameters and are       renewed in the screen     GDV Sport  gt  Working with program  gt  Noise filtration     
9.  will be used  for correction  and keeping the keyboard   CTRL   button pressed move the contour border           Pinte Sport        Eneroy paene HI Noise  Smith   2011 03 13 16 25    GDV images without fiter   GDv images with filter                        Calibration      R J oad GDV images     lt  lt  Back Calculate           nn       Besides  sector division of the corresponding finger is superimposed on the GDV images  Detailed information on the  GDV image can be obtained using the mouse     e when you move the cursor over the image the information is displayed in the lower part of the window        cts Sport       Ener ate v  EA E EE noe   Gnin  201103131625    GDV mages without filter   GDV 4mages with filter                              r    Omaa Cport       ens    EA EE ne   Gnin  20110313 1625      GDV images without fiter   GDv images with fiter                  Calibration    Print GDV mages    Capture GDV mages    Load GDV mages             N       GDV Sport  gt  Working with program  gt  Correction of the center and ellipse for the GDV image of finger       GDV Sport  gt  Working with program  gt  GDV Image menu       GDV Image menu       Contextual pop up menu can be called for any loaded GDV image  Press right mouse button in the line showing  frame   s number and path to the file  Contextual menu appears  It consists of the following items        r        Eneray palette HIR Noise  Smith  2011 0313 16 22    GDV images without filter   GDV images with filter   
10. 25                 b    E REE SE LRT  RE             ad G    Calibration    Print GDV images    Capture GDV mages    Load GDV mages     lt  lt  Back Next  gt  gt              N A       A GDV image is a number of points  pixels  each of which is characterized by the glow intensity   a value within 0   255  Zero  intensity corresponds to the absence of glow in the given point  and 255 indicate maximal glow intensity     The GDV image spectrum is the function that determines the number of points with specified intensity  Fig  shows a typical GDV   image spectrum  The horizontal axis shows the intensity and the vertical one the number of image pixels with preset intensity  Any  video camera used to register GDV images has a certain error of performance  Therefore the images contain evenly spread    noise     points of low intensity  The figure shows the part of spectrum corresponding to there noise pixels in grey  The blue color indicates the  spectral region corresponding to the brightest and most informative point of gas discharge glow around the subject     CAGDVData Smith Without filter 1R bmp Bie ks                GDV Image   Spectrum   parameters   Information   Isoline   Calibration data  6266                   Spectrum parameters  Maximum intensity  255  Minimum intensity  2  Mean intensity  24   RMS error of intensity  26  Peak intensity  18  Spectrum width  253    Pixel count    Histogram position  Intensity  44  Pixel count  177  Noise level  30  Pixels count axis maxi
11. 3 2011 4 18 26 PM isn t loaded isn t load   w p       to enter changes in the personal data of the selected subject            The button   Remove from list   enables you to remove the selected recording about the subject from the program   This action does not result in data file removal from the disk but only increases the memory space     Using the button you can delete all loaded data from the program memory        To work with the lower list the following buttons are provided     s   to add a new capture for the subject selected in the upper list     e   Edit data     to introduce changes and to add comments to capture selected in the lower list     s   to delete capture selected in the lower list     e To save changes press    Save changes          To switch to another GDV image page use the button    Next          GDV Sport  gt  Working with program  gt  Adding an entry of a new subject data       GDV Sport  gt  Working with program  gt  Loading GDV images       Loading GDV images          Loading of GDV images is done on the GDV images page and also in the subject   s window with the   Load GDV  images   button  it is highlighted with the color in the figure   The files of GDV images are to have in their name  the finger indices 1R   5R  1L   5L     r       Oraa Cport        H Noise    Smith   2011_03_13 16 22    GDV mages without filter                Calibration                   To load GDV images you need to press the button   Load GDV images   in the shown up win
12. 7 37 PM   GDV device model  GDV Camera Pro with analog videocamera  FTDI  13 6001  110310   Path to GDV images files C  GDVData  Calibration    Radius error 0 01    should be less then 2 00      Area error 1 46    should be less then 5 00      Intensity error    Filename Date and time of capture    0001 bmp 6 4 2011 12 07 09 PM  0002 bmp 6 4 2011 12 07 12 PM         The renewed calibration data will be automatically recorded into all GDV images of the series that you see on the    screen  both with and without filter  if any    For an arbitrary set of GDV images       Make sure that all programs of the GDV Software package are closed     Run any program of the GDV Software package  except GDV Capture  GDV Viewer  GDV Scilab     Go to page of the list of subjects  DO NOT LOAD sbj files      Select in the menu Action the item Group calibration          OTa Sport       Calibration          L    New subject Load subject       Add new subject entry or  load data from disk    GDV capture data is not added          New subject    Load subject data  Load per list    Last calibration info     Calibration       Group calibration       Close the program                   5  The GDV Capture 2 program will start  Press the   Load GDV images   button in the upper left hand corner of the    program window and select the GDV images of the test object that need recalculation                    Load GDV images       GP see          Energy palette X    Type of connected GDV device  GDV Camera P
13. DV images     The demo version makes it possible to work only with built in data  the functions  of creating  loading and saving files of subjects are blocked  you also can not load  GDV images from disk or start the GDV Capture to capture these files     The program can simultaneously carry out the data processing for several subjects  with a possibility of having several GDV captures for each of them  e g   taken on  different dates   A GDV capture is one or two sets of files of GDV images of fingers  taken with and without filter  In this program only GDV images without filters are  required     The list of captures and personal data of the subject  name  gender  age  etc   are  saved in the file or on the disk  Therefore to process the subject   s data it is  necessary either to create a new file  or to download the previously created one  and then add the new capture  When you want to close the program or delete  subjects from the list  a request will be made if you need to save all changes  during this session    Thus a typical working procedure looks as follows     1  Create a new file or download the existing one    2  Add the new capture    3  Download the subject   s GDV images without filter    4  Calibration  if this procedure has not been carried out before     5  Check settings of noise filtration  pseudocoloring mode  and if necessary   introduce your corrections    6  Corrections of inner ellipses     7  Processing and analysis of the obtained data   8  Printi
14. EMF  formats      enable to save the file of the printed page in Windows Bitmap  extension BMP  or Windows      changes the scale of the preview page    Information on the number of pages is shown in the window status bar        After pressing button   Print   window Print setup appears  If you have a color printer  the printer is automatically set for  color printing   Landscape  page setup is given by default     GDV Sport  gt  Working with program  gt  Printing out GDV images       GDV Sport  gt  Working with program  gt  Saving printed documents  Saving printed documents    Any document  a graph or GDV image  that is formed in the program can be saved    from the Print preview window  To do this press the button  Save to file   in the    upper part of this window     The type of file is Windows Enhanced Metafile by default  EMF extension   but you  can also select Windows Bitmap  BMP extension      It is advised to use the EMF format for saving pages  as  first of all  images occupy  much fewer space on disk in this format than in BMP format  Secondly  when these  images are scaled in documents  for example  in Microsoft Word  distortions are  minimal     GDV Sport  gt  Working with program  gt  Saving printed documents    
15. GDV Sport  gt  Introduction    GDV Sport    Introduction  Purpose of the program  System requirements  Recommended computer configuration  Training level of a user  Working with program  General description of the program  Adding an entry of a new subject data  Loading GDV images  Capturing GDV images  Calibration  Group calibration  Noise filtration  Pseudocoloring modes  Correction of the center and ellipse for the GDV image of finger  GDV Image menu  Data table  Summary  Additional information  Printing out GDV images  Saving printed documents    GDV Sport  gt  Introduction    GDV Sport  gt  Introduction  gt  Purpose of the program    Purpose of the program    The GDV Sport program is designed to evaluate the psycho emotional status  parameters expressed as peer review diagnostic decisions and integral indices  reflecting the energy functional level of human body based on GDV images of  human fingers  The calculated parameters and indices express the potential of     successfulness    in the subject   s activity     The program is intended for evaluating the potential successfulness and efficiency  of athletes and staff members of companies  The individual rating of a person in  the group is based on these characteristics     The method is based on high correlation  correlation coefficients are more than  0 85  of the indicated parameters and indices calculated independently by means  of tests and peer review decisions  with geometrical and brightness characteristics  of G
16. ain          Automatic capture       5  Press in the upper left hand corner of the program window and select GDV images of the test  object that need recalculation           370 x 285  Energy level  1  Image transformation  No transformation                                    Tun  aiinos    Static GDV images  bmp  L    Parameter name Parameter value                6  Press and then   Save calibration results   and close the GDV Capture 2 program        CBO    DS Gl B   el regain C HD    Ey   catbraton o00s  EY   cabration 0002 HB    Catbration ooo3 IB aperas JE  oanez       Parameter Value    Date and time of calibration 6 4 2011 12 09 29 PM  Date and time of GDV images capture 6 4 2011 12 07 37 PM  GDV device model  GDV Camera Pro with analog videocamera  FTDI  13 6001  110310   Path to GDV images files C  GDVData Calibration   Radius error 0 01    should be less then 2 00     Area error 1 46    should be less then 5 00     Intensity error 1 21    should be less then 5 00     13911  13942  58    Filename Date and time of capture Inner radius irregularity Area error Intensity error    0001 bmp 6 4 2011 12 07 09PM 0 56    tolerance 4 00    6 82    tolerance 15 00   1 75    tolerance 8 00     0002 bmp 6 4 2011 12 07 12PM 0 55    tolerance 4 00   7 08    tolerance 15 00   1 99    tolerance 8 00       Dependence of the test object s glow area on noise level       AUNE    Value    Date and time of calibration 6 4 2011 12 09 29 PM   Date and time of GDV images capture 6 4 2011 12 0
17. cases the contour almost absolutely repeats the finger contour  However  sometimes the glow has outbursts and dark  areas  as a result of which the finger contour built automatically is not precise and requires manual correction  In this  case the contour can be manually adjusted  the position of the center and the finger orientation can be corrected in  order to have a more precise energy field picture     In order to correct the finger center position  move the mouse cursor to the displayed GDV gram center  press the left  button and move the cursor keeping the right button pressed        r            E Noise    smith  2011_03_13 16 25    GDV images without filter   GDv images with filter                      1  1    B woon stert HH waar oC HB atan  10                 Calibration    Print GDV mages    Capture GDV mages    Load GDV mages          N       The finger orientation on a GDV gram can be corrected in a similar way  In order to do that  move the cursor to one of  the displayed GDV gram axes  press the leftt button and move the cursor keeping the left button pressed  The kept axis  will be rotated against the GDV gram center        Pa xe   L        Eneroy paene    EA GG  Noise  Smith   2011 03 13 16 25    GDV images without fiter   GDv images with filter                        Calibration      Bice C J oad GDV images     lt  lt  Back Calculate                     In order to correct the contour  mark the corresponding GDV gram  move the cursor to touch the axis which
18. center exceeds the specified value are removed     It should be emphasized that during the filtration procedure there is no physical removal of information from images  all further  calculations in the program are done as if all filtered pixels had zero intensity  Therefore you can change the noise filtration  parameters any time  not losing the data on noise pixels     The noise filtration parameters settings are carried out by the user  The two main factors to select these parameters are the type of  the used GDV Camera and specific features of the recorded GDV images  In the Operation Manual to the GDV Camera you will find the  recommendations helping to determine the correct parameter values  You need to follow the principle of selecting the most contrast  part of the glow that can usually be seen with a naked eye  It is also important  when you are registering the test object images  to  ensure such filtration parameters that the inner part of the glow would not contain noise pixels  For the convenience of selecting  optimal parameters of noise filtration the program can switch to different types of image pseudocoloring  You can use the following  way to control the correctness of the chosen parameters     1  Set the   intensive   or   energy   palette for loaded images    Select the noise filtration parameters so that to avoid a large number of yellow dots    Switch to the   initial image   palette    Switch off the display of the filtered points    Make sure that the v
19. dow and indicate the  path to the folder where the GDV image set is stored  then press the buttons l Select all   and  Open                     Tans  J  Smith  6 E G fv  Dera vamenenua Th      13 03 2011 16 16  02 03 2011 16 02          Vima  Ji With filter  J Without filter                                         Vima pa  na     Tun atines   Static GDV images bme     Parameter name Parameter value                                     Calibration                              5R  lt  Select all            Vima pa  na     5R bmp   1Lbmp   1R bmp   2L bmp   2R bmp   3Lbmp   3F v Open            Tun pa  nos   Static GDV images C pnp  S Rs          Parameter name Parameter value                      The pictures of the subject   s GDV images are loaded into the GDV image window        Pinte A       Noise    Smith  2011_03_13 16 22    GDV images without filter   GDv images with filter                  b    By    without meris 18   without fiter 2R HB   without nrzranp HH   without G          Calibration    S    Capture GDV images             GDV images taken without filter are loaded into the program     Use the button for calibration of the loaded GDV images     Use the button   Print GDV images   to print out the pictures of the loaded GDV images with an overlay of sector  division by Korotkov     Use the button if you want to reload GDV images     GDV Sport  gt  Working with program  gt  Loading GDV images    GDV Sport  gt  Working with program  gt  Capturing GDV images       Cap
20. ension  sbj   GDV Diagram  GDV Energy Field  etc          GZ   Folder pattern  ka   File name pattern  k         Type of files in thelist   Data files    sbj           File name  C  GDVData GDVEnergyField Crystal sbj  C  GDVData GDVEnergyField Fisher  sbj  C  GDVData GDVEnergyField Luz sbj  C  GDVData GDVEnergyField Rooney sbj  C  GDVData GDVEnergyField Smith sbj             Number of files in the list  0          Calibratic         2  Go to the GDV image page and select the required series     3  Press   Calibration      in the lower left hand corner of the program window  or select the item Calibration    from  the menu Action                rts Sport              SK  Noise    Smith   2011_03_13 16 25    GDV images without filter   GDV images with filter                      L       i    B     without nter  HB  without fiter ar HB met nena  HB  without merat HH without prest                Calibration    Print GDV mages    Capture GDV mages    Load GDV images    Calculate       4  The GDV Capture 2 program will start  For further work press   OK   of the warning pop up window              Type of connected GDV device  GDV Camera Pro with analog videocamera  FTDI 13 6001 110310   Image size  370 x 285   Energy level  1   Image transformation  No transformation                     To complete calibration  capture at least 10 GDV images   ve of the test object and save them or load earlier captured images   L       Then press  Process  button     E  Do not show this message ag
21. f anxiety  stress     SB within 0 2   a totally calm  completely relaxed person  which may be the result of several factors  a  deep meditation  complete inner peace  the influence of psychedelics  a deep sleep in a quiet phase  chronic  depression  etc    SB 2 4   a normal quiet state    SB 4 6   an excited state characteristic of active work  excitement  intense activity    SB 6 8   at least four possible situations     e a response to a previous stressful situation  an unpleasant conversation  illness  failure in the training  process  driving in stressful conditions  etc       e increased nervousness or stress accumulated over long periods of time  emotional stress  vegetative  dysfunctions     e people with a special type of mentality that can quickly switch from the state of extreme excitement  and nervousness into a quiet state     e the state of overtraining  fatigue  danger of injury     SB in the range of 8 10   a very high stress background  the peak of excitement               Category    All selected categories             Sort criterio  Score  Descending  X    Capture Capture Energetic Stress    as EE date category Score potential level  1  Smith 2011_03_13 16  4 3 2009 10 46 59 AM 3 217            Print          The data table can be saved to a text file or printed out     When you print out the rating table you can indicated the name of the group to which the subjects refer  e  g    swimming   The entered names are saved and you can select them afterwards  If 
22. frame  are colored in yellow  All  image points removed by noise filtration are shown in white       Solid palette   all image points removed by noise filtration are shown in black color  the rest of the points  are shown in a monotonous bright color  Use this palette analyzing sector   s glow area and glow area of the  whole image in order to avoid optical illusion  which can occur if some points are not seen well  as the  coloring is similar to the coloring of    noise    points     Blue palette   color palette containing 256 shades of blue  from black to bright blue  is used  Points with  minimal intensity of glow are shown in dark  almost black  shades  points with maximal intensity of glow  are shown in bright  almost blue  shades  This palette displays the glow similar to the way it can be seen in  instrument   s electrode by the naked eye     Energy palette   the image points are colored in one of the nine colors  The brightest glow points  are colored in blues  the less bright ones are colored in reds  oranges and violets  All image points removed  by the noise filtering algorithm are displayed in white     GDV Sport  gt  Working with program  gt  Pseudocoloring modes       GDV Sport  gt  Working with program  gt  Correction of the center and ellipse for the GDV image of finger       Correction of the center and ellipse for the GDV image of finger       Determination of the ellipse and glow center is built automatically when the GDV grams are load ed  In most of the  
23. ional activity of body and systems  The  state of energy deficiency can be attributed to total breakdown  dysfunctions of separate organs or systems  overfatigue   neuro psychic stress  over training  In this state the subject can function normally  in particular  an athlete can show  good results  however a long period of such state leads to development of negative processes on psycho physiological or  somatic level     Necessity check up   at the moment of measurements the subject is under stress which makes it impossible to  adequately evaluate his psycho physiological readiness  The given situation requires a more detailed psychological and  medical examination     In the table     marks the qualities which by the result of processing GDV images are mostly pronounced for the  subject        C TTS A       Category    All selected categories    zj       Smith  2011_03_13 16 25       Print             Press   Print      to print out the obtained data              Press   Save      to save the results        E              Si  S2 53 54 S5 C1 C2 C3   C4 C5   D1   D2 D3 D4 DS            Sport valuable merits   S1  Activity   S2   Purposefulness    3   Self reliance   S4   Stress resistance  S5   Self regulation    Before nosologic changes   C1   introspection   C2   Unsolvable dreams   C3   Amotivational anxiety   C4   Deterioration of efficiency  C5   Irascbility  irritability    Dysadaptation states    D1   Troubled hypohondriacal states  D2   Tendency to solitude   D3   Vege
24. isible peculiarities of the subject   s glow have not disappeared from the screen   Switch to the   monotonous palette       Nau pWN    Make sure that the bright blue dots do not fill the entire or almost entire glow area   8  If necessary  repeat the procedure     Naturally  the procedure of selecting the parameters is done only once using several samples of GDV images of fingers and GDV   images of the test object captured with the given GDV Camera     Several parameters of noise filtering are offered in the program     Press       la a     a a e Sport                Smith   2011_03_13 16 25        GDV mages without filter   GDV images with filter            Noise filter parameters is  Abs  noise level  30       Rel  noise level     100       Base intensity    Threshold  Min  fragment area  30  Work radius  0    Indude inner ellipse glow   V  Intensity correction                BT JE   wehout teria  JE without teria  PE    wihout erat  JE without ter                 Calibration    Print GDV mages    Capture GDV mages    Load GDV mages     lt  lt  Back Next  gt  gt              Absolute noise level   removal of all the image points whose intensity is lower or equal to the given noise level  It is  recommended to select the value individually for each session of recording within the limits from 10 to 60     Relative noise level       the program automatically selects absolute noise level on the basis of the given percent of the  value of base intensity  This algorithm selects
25. mum 6266    KG                 C  GDvData smith  Without fiter 1R bmp 7                The video camera performance error is not the only noise contribution to GDV images  It also may be dirt on the work surface of the  instrument  It may result in separate bright spots or fragments that also should be filtered     As a result  noise filtration of GDV images is carried out in two stages  First  you need to remove pixels whose intensity is equal or  less than a certain limit  There are two ways of setting this limit     1  The limit is set directly  a corresponding parameter of the program is called   absolute noise level     2  The limit is determined automatically for each image by a certain characteristic of the GDV image spectrum                  SK  Noise    Smith   2011_03_13 16 25    GDV images without filter GDV images with filter                 Noise filter parameters r   2    Abs  noise level  30           Rel  noise level     100 S A 7 3    i Base intensity  Threshold k B          Without fiter 5R    Min  fragment area  Mean  5      Median  Work radius  peak  Include inner ellips Threshold  6  d Intensity correction 2             Coox   cancel  6                          Calibration    Print GDV images    Capture GDV mages    Load GDV mages     lt  lt  Back Next  gt  gt                 The latter method is regulated by the two parameters     relative noise level   and   basic intensity    A relative noise level determines  the percentage of the limit value for filt
26. n in the GDV image processing programs           To carry out calibration you need to press   Calibration      in the left lower part of the GDV images window              E    Pie te S pert       Noise    Smith   2011_03_13 16 25    GDV images without filter                  Calibration             V          The program GDV Capture will be launched in the calibration mode     A more detailed description of calibration process  loading or capturing GDV images see in the instruction to the  GDV Capture program in section Working with program GDV Capture     GDV Sport  gt  Working with program  gt  Calibration    GDV Sport  gt  Working with program  gt  Group calibration    Group calibration       Beginning from version 2 7 0 of the GDV Capture 2 program the algorithm of obtaining calibration data was considerably  improved  while the format of saving information and the set of the calculated parameters were not changed  Therefore  if you  process GDV images that were previously recorded by an earlier version of the GDV Capture 2  earlier than 2 7 0  in the new  versions of GDV Software  beginning from 2010  the results will be incorrect  To avoid this it is necessary to recalculate  calibration data in the latest version of the GDV Capture 2 program and to save these data into GDV image files     You can do it in two ways     1  For one selected series of a single subject     1  Load the sbj file of the subject into any program of the GDV Software package working with the ext
27. ng and saving the results     GDV Sport  gt  Introduction  gt  Purpose of the program    GDV Sport  gt  Introduction  gt  System requirements   System requirements   The program can be operated in the following Microsoft Windows operating  systems     e Windows 2000  e Windows XP   e Windows Vista  e Windows 7    Recommended computer configuration    Recommended computer configuration     e 32 bit  x86  or 64 bit  x64  processor with a clock speed of 1 gigahertz   GHz  or higher     e 1 gigabyte  GB   32 bit system  or 2 GB  64 bit system  memory  RAM      e 16 gigabytes  GB   32 bit system  or 20 GB  64 bit system  hard disk  space     e graphic device DirectX 9 or higher     Training level of a user    Training level of a user   e user should have skills of work with Windows OS    GDV Sport  gt  Introduction  gt  System requirements    GDV Sport  gt  Working with program    Working with program    General description of the program  Adding an entry of a new subject data  Loading GDV images   Capturing GDV images   Calibration   Group calibration   Noise filtration   Pseudocoloring modes   Correction of the center and ellipse for the GDV image of finger  GDV Image menu   Data table   Summary   Additional information   Printing out GDV images   Saving printed documents    GDV Sport  gt  Working with program    GDV Sport  gt  Working with program  gt  General description of the program       General description of the program       The interface of the GDV Sport is arranged as
28. o be open  You can edit the list using the  following buttons     s A enables to add to the list the files with  sbj extension from the selected folder on the disk   U x deletes all selected files with  sbj extension from the list       B deletes all files with  sbj extension from the list     Using the Folder pattern and File name pattern you can load into the list not all files but only those that meet  a specific condition  In these input fields you can enter any part of the folder or file name  You can also use the  two special symbols     and          means any number  including 0  of any symbols      means just one symbol   For example  you have a set of files of 10 fingers and you need to open the files with fingers of the right hand  taken with filter  To do it you type  Filter  in the Folder pattern field  and type  R  into the File name  pattern  naturally  you need to name the files and folders on the disk in an appropriate way   Then when you  scan the selected folder  only the required files will be loaded into the list     When you have finished selecting the parameters press  OK         C TTS A 7                                                      Edit data       Use the button              Subject name Sex Age Capt  count Remark  1  Smith male 20 2  New subject Load subject Load per list Edit data Remove from list  Category      GDV capture Date Without filter With filter  1 2011_03_13 16 15 4 3 2009 10 46 59 AM is loaded is loaded     2  2011_03_13 16    3 1
29. ou press the button   New subject   the subject   s personal data window will show up        CYT VI Sport       File name  C  GDVData Subject 1 sbj Browse          Personal data  Name  Subject 1                   Sex   male    Birthday  13   3    1991    day month year          Remark     GDV Capture data  GDV Capture name  2011_03_13 16 06 Date      New sul Category  x   Edit      Remark              GDV mages without filter    No data    Capture GDV images  amp  Load GDV images    GDV images with filter           No data             G Capture GDV images          The file name with the  sbj extension to where the subject   s data will be saved is formed by the program  automatically based on the subject   s name and the current path to the GDV data base  This path is normally  selected by the user when installing the software and it is not to be changed further on  However  using the button    you can indicate a new path to the GDV data base     In the upper part of the window enter the subject s personal date  name of subject   in the line Name  e g     Smith   indicate the date of birth  select sex  and  if necessary  put down your comments to this subject  Button    BS            enables to enter or edit the date of birth using the calendar     CTI Sport                                        File name  C  GDVData Subject 1 sbj Browse     Personal data  Name  Subject 1  Sex   male wij Birthday  13   3   1991    day month year  Remark  a  GDV Capture data  GDV Capture name
30. ration calculated from the selected basic intensity  There are 5 options of basic intensities     Average   an average intensity calculated by analysis of all points of image    Average   RMS   an average intensity of all points of image plus standard intensity deviation   Median   a median of the image points intensities    Peak   the most frequently met intensity value     Threshold   a value exceeding the intensity peak  the number of pixels containing this value is less than 1  of the total amount  of image points      H S T L    At the second stage of filtration a list of image fragments is built   groups of glow pixels situated nearby  the principle of 8   connectedness is used  two points are neighboring if their coordinate values have not more than one unit difference  i e   the  neighboring of the given points are those being in one of the eight nearby positions  For each fragment the area is calculated  i e   the  number of pixels in it  Then you need to remove from the GDV image all fragments whose area is smaller than the specified one  It is  regulated by the parameter   minimal fragment area    The value of this parameter is 10 by default and usually does not require any  changes     For the convenience of processing GDV images of liquids  that may splash during a discharge   and also if there is edge flare  external  lighting   another parameter has been introduced    the   working radius    If this parameter is non zero  all pixels whose distance to  the glow 
31. ro with analog videocamera  FTDI 13 6001 110310        Image size  370 x 285  Energy level  1  Image transformation  No transformation                                                                     Tun pa  nos    Static GDV images  bmp           Parameter name Parameter value             6  Press   Calculate       D Su Te Eeo C AD    SS SSS  E  amanen So lB mania                  7  Then press   Save calibration results   the GDV Capture 2 program will close        Value    Date and time of calibration 6 4 2011 12 09 29 PM   Date and time of GDV images capture 6 4 2011 12 07 37 PM   GDV device model  GDV Camera Pro with analog videocamera  FTDI  13 6001  110310   Path to GDV images files C  GDVData Calibration    Radius error 0 01    should be less then 2 00      Area error 1 46    should be less then 5 00      Intensity error 1 21    should be less then 5 00       Filename Date and time of capture Inner radius irregularity Area error Intensity error  0001 bmp 6 4 2011 12 07 09PM___0 56    tolerance 4 00    6 82    tolerance 15 00   1 75    tolerance 8 00     0002 bmp 6 4 201112 07 12PM 0 55    tolerance 4 00    7 08    tolerance 15 00    1 99    tolerance 8 00       Value    Date and time of calibration 6 4 2011 12 09 29 PM   Date and time of GDV mages capture 6 4 2011 12 07 37 PM   GDV device model  GDV Camera Pro with analog videocamera  FTDI  13 6001  110310   Path to GDV images files C  GDVData Calibration    Radius error 0 01    should be less then 2 00      Area e
32. rror 1 46    should be less then 5 00      Intensity error    Filename Date and time of capture    0001 bmp 6 4 2011 12 07 09PM 0 5 75    tolerance 8 00     0002 bmp 6 4 2011 12 07 12PM 0    1 99    tolerance 8 00          8  The window with a list of GDV images into which the renewed calibration data needed to be recorded will open     Press   Add all files from selected folder   to select one or several file from any folder  or press   Load from folder    to load all GDV images from the selected folder  the folder is scanned recursively            E     Folder pattern      File name pattern    Q  x       Type of files in thelist   Data files    sbj           NS File name             Number of files in the list  0                   Type of filesin thelist   Data files    sbj           File name  C  GDVData GDVEnergyField Crystal sbj  C  GDVData GDVEnergyField Fisher  sbj  C  GDVData GDVEnergyField Luz sbj  C  GDVData GDVEnergyField Rooney sbj  C  GDVData GDVEnergyField Smith  sbj                   Number of files in the list  0       Calibrat       10  Save the data with the new calibration     GDV Sport  gt  Working with program  gt  Group calibration       GDV Sport  gt  Working with program  gt  Noise filtration       Noise filtration       The window Noise filter parameters is opened using the button in the upper part of the Dynamic GDV images page           a x                   Seats AE    GDV images without filter   GDV images with filter        Smith   2011_03_13 16 
33. s levels of organization and complexity  Mental self regulation is one of the levels of regulating the  activity of theses systems expressing the specific character of mental properties of reflection and modeling the reality  which realize it  including the subject   s reflections        Before nosologic changes    Introspection   observation of one   s own mental life  going deep into one   s own thoughts         Unsolvable dreams   an effort to find a solution of unsolvable problems at subconscientious level during sleep        Unmotivational anxiety   a symptom of psychoemotional disorder     Deterioration of efficiency   a decrease of an ability to perform expedient activities at the given level of efficiency  during a certain time period     Irascibility  irritability   a non controlled inadequate psychoemotional subject   s response to exogenous irritants     Dysadaptation states    Troubled hypohondriacal states   a depressive psychological disorder  with obsessive and overvalued alarms  referred to one   s health     Tendency to solitude   a psychoemotional state characterizing a state of depression both endogenous  without any  evident reasons  and reactive  response to psychotraumatic reaction      Vegetative dysfunction   it is combined with emotional disorders and expressed in vegetative manifestations   giddiness  sweating  chill  shivering  arterial pressure variations  lack of air     Energy deficiency state   states indicate insufficient energy supply of funct
34. t    GDV capture data is not added             In the upper right part of the page Subject list there is the menu of the program             When you click on the button the menu will appear with a list of all pages where you can arbitrary switch  to other pages of the program  The current page is checked  you can choose another one with the left mouse  button but you need to consider that part of pages will be available only after the loading or processing of the       GDV images  You can switch between pages during work using buttons       Previous   and       Next          or in the lower right part of the page Subject list     in the menu Page       inte    Tport       Next    Previous    Welcome to the program  Add new subject entry or v Subject list  load data from disk GDV images  Data table    Summary    Additional Info    New subject Load subject Load per list Remove from list       GDV capture data is not added             If GDV images are loaded there is an opportunity to switch between necessary pages in the menu Page     If you press the button a menu will show up with a list of possible actions on this page including both  operations common to all pages of the program     New subject        Load subject   s data     etc  and specific operations  for the current working window  For example     Group calibration      this option allows recalibration of gdv images  which were calibrated earlier with new algorithm of calibration        Pinte    Tport    temove capt
35. t there will show up the entries about the          Before the subject   s name and names of captures there are checkmarks to check uncheck the processing of a  single subject or capture  It means that you can process view not all loaded ones but only selected sets of  captures  and not only loaded subjects but only selected ones  To check uncheck you need to double click the left    mouse button        C TTS A 7                                     To work with the upper list the following buttons are provided below the list             Subject name Sex Age Capt  count Remark  1  Smith male 20 2  New subject Load subject Load per list Edit data Remove from list  Category      GDV capture Date Without filter With filter  1 2011_03_13 16 15 4 3 2009 10 46 59 AM is loaded is loaded     2  2011_03_13 16    3 13 2011 4 18 26 PM isn t loaded isn t load   w p    The button   Load subject   enables to load information about the subject from the previously saved file     The   Load per list   button enables to for a list of files of subjects and to load this data into the program from the  window   Files list composing                     File name pattern     Q x         Type of files in thelist   Data files   sbj           File name  C  GDVData Fisher sbj  C  GDVData Smith sbj  C  GDVData Crystal sbj  C  GDVData Luz sbj  C  GDVData Rooney sbj                            Number of files in the list  5                   The window shows a list of files with extension  sbj  which need t
36. tative dysfunction   D4   Energy deficiency state   D5   Necessity for check up       Press the button   Go to the subjects    page   to return to the page with the List of subjects     GDV Sport  gt  Working with program  gt  Summary          GDV Sport  gt  Working with program  gt  Additional information       Additional information       On the last page it is possible to correct or add the additional comments to the Subject or Capture  This  information will be saved in  sbj file        r             Smith       Subject Information     GDV Capture Information     12011 03 13 16 25                   GDV Sport  gt  Working with program  gt  Additional information    GDV Sport  gt  Working with program  gt  Printing out GDV images       Print GDV images    The program makes it possible to print out the loaded GDV images with sector division  Press on the  GDV image loading page     Before printing the program will open the preview window  from where the image might be printed or saved      cose  La  Gisa   x  b gt    eau        Smith   2011_03_13 16 25  GDV im ages without filter       There are several buttons in the tool bar of this window                                         60              Close    closes the preview window  Print        switches to window  Print setup   followed by printing   lt  lt   gt  gt      enables to view the previous page and next one    I lt  lt    enables to view the first page and the last one    Safe to file  Enhanced Metafile  extension 
37. technical state of the GDV camera and for the analysis of glow area of  test object which is necessary for proceeding in different programs of GDV Software     You need to perform calibration in the following cases     s Before starting to work with a new GDV device    e When you connect the GDV device to a computer that has not been used for calibration   e After switching from the AC DC adapter 110 240V 12V to the battery  and back     e When you bring the GDV device from one room to another or outdoors and back     e When the climatic conditions in the room where you capture GDV images change  if the temperature  difference is more than 5  C or humidity difference is more than 10       e In presence of an outer electromagnetic radiation source near to the GDV device or when the GDV device is  taken to a place with normal or low electromagnetic noise level from a place with high electromagnetic noise  level     e Also  once in 6 months     The calibration process begins with capturing or loading GDV images of the test object  You will need no less than  10 GDV images of the test object for processing  the first 5 GDV images should be recaptured   Before processing  you need to save all GDV images     It is important to make sure that GDV images of the test object have no defects  for example  due to  misplacement of the test object  illumination or dusty inner circle  etc  Such defects can distort calibration data  which will make it impossible to obtain reliable informatio
38. the name of the group is not  obligatory you need to press   Cancel                     C TTS A       Category    All selected categories             Sort criterio  score  Descending  X    Capture Capture S Energetic Stress    as EE date category potential level  1  Smith 2011_03_13 16  4 3 2009 10 46 59 AM 3 21 7      Enter group name       swimming                         Print          GDV Sport  gt  Working with program  gt  Data table    GDV Sport  gt  Working with program  gt  Summary       Summary       The page Summary contains a table where the qualities of the following categories are mentioned     Sport valuable merits    Activity   a subject s ability to change the situation or an attitude to it in the absence of the definite prognosis of its  results but continuously taking into account the degree of its efficiency        Purposefulness   a psychoemotional state characterizing readiness and emotional motivation in reaching the goal        Self reliance   a volitional quality that shows in calm perception of his own abilities and advantages by the subject        Stress resistance   the constellation of personal qualities which enable the subject to stand high intellectual  volitional  and emotional overloadings due to peculiarities of his professional activity without harmful after effects for himself and  other people        Self regulation   regulation    from Latin regulare     to bring to order  to adjust      expedient functioning of living  systems of variou
39. turing GDV images  On page there is the button that makes it possible to capture GDV     images from any program of the GDV Software package           r        3K  Moise    Smith   2011_03_13 16 25          GDV images without filter          Calibration     lt  lt  Back N     Load GDV mages             The GDV image capture process is carried out in the GDV Capture program  When you save the captured GDV   images in this program the following structure of folders on the disk will be automatically created      lt Subject 1 gt  sbj   lt Subject 1 gt   GDV Images    lt Name of capture 1 gt   GDV images without filter  1R bmp  2R bmp  3R bmp    GDV images with filter  1R bmp  2R bmp  3R bmp    The lines containing in  lt   gt  will be replaced by data input by the operator when creating the subject   s account and  during GDV capturing     Until the GDV Capture is closed the work of the program from where the call is made will be blocked  After  saving the captured GDV images and closing the GDV Capture program the images will automatically load to the    GDV images window  The protocol of capturing GDV images is described in details in the instruction to the GDV  Capture program     GDV Sport  gt  Working with program  gt  Capturing GDV images    GDV Sport  gt  Working with program  gt  Calibration       Calibration       Calibration of GDV devices is the process of registration of number of GDV images of test object and processing of  the images with the purposes of control of 
40. ure          Add new subject entry or  load data from disk       New subject Load subject Load per list Remove from list    GDV capture data is not added              New subject    Load subject data  Load per list    Last calibration info     Calibration       Group calibration       Close the program                         TTS    Tport             Subject name Sex Age Cap   1  Smith male 22          Gan  a  ee  a  Gee     Category      GDV capture Date  1  Capture2 4 3 2009 10 46 59 AM            New subject  Edit subject data    Remove subject from list    Load subject data  Load per list  Save changes       Clear list    Add capture  Edit capture data    Remove capture    Last calibration info       Calibration       Close the program       a  H    Add capture Edit data                   Edit capture data                 CTs port      GDV Capture data    GDV Capture name  Capture 2    Date  4 3 2009 10 46 59 AM       Category        Remark        ____ GDV images without filter    C  GDVData smith Without filter   Catego     GDV images with filter    C  GDVData Smith With filter                     9 Capture GDV images Load GDV images        Capture GDV images                   SVT V7  Sport           Noise  Smith   Capture 2 Go to subject s page    New subject          GDV mages without filter   GDV images with filter         Save changes       Capture GDV images     Load GDV images       Print GDV images     Recalculate all    Last calibration info       Calibration    
    