Home

A9GT-J71E71-T type Ethernet communication module User`s Manual

image

Contents

1. 2 Mount the A9GT J71E71 T on the GOT interface 3 Tighten and fix the mounting screws 3 pcs of the A9GT J71E71 T in the specified torque range 36 to 48N cm 4 Connect the twisted pair cable to the A9GT J71E71 T 5 To remove the unit reverse the installation procedure Grounding work for the 1OBASE T 10BASE5 and 10BASE2 requires appropriate safety measures Consult professionals for work details including terminal of connection cables and other plant work such as laying of main cables Ethernet is a registered trademark of Xerox Corporation U S Other business or product names mentioned herein are a trademark or registered trademark of each company Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This
2. Manual describes the A9GT J71E71 T type Ethernet communication module hereinafter A9GT J71E71 T The A9GT J71E71 T is required when performing Ethernet connection or Gateway function with GOT For details of the Ethernet connection Refer to the GOT A900 Series User s Manual GT Works Version5 GT Designer Version5 compatible Connection System Manual For details of Gateway function Refer to the GOT A900 Series Operating Manual GT Works Version5 GT Designer VersionS5 compatible Gateway Functions Manual After opening the box check that the following items are present AQGT J71E71 T Install all relevant operating systems Standard monitor OS Communication driver Extended function OS Ver 9 0 0 or later and ROM_BIOS Ver 9 0 2 S or later contained in version 26C or later of GT Works Version5 or GT Designer Version5 into the GOT for A9GT J71E71 T with hardware version E 2002 June or later The product will not work with the operating system contained in version 13P to 22Y of GT Works Version5 or GT Designer Version5 2 Specification 2 1 General Specifications Specifications Operating ambient 0 to 55 C temperature Storage ambient 20 to 60 C temperature Operating ambient 10 to 90 RH non condensing humidity Storage ambient 10 to 90 RH non condensing humidity oe ee Incaseof 10to57Hz 0 075 mm 10 times in Vibration intermittent each of X resistance ee vibration 57 to 15
3. end user DESIGN PRECAUTIONS DANGER Do not bundle control lines or communication wires together with main circuit or power lines or lay them close to these lines As a guide separate the lines by a distance of at least 100 mm 3 94 inch otherwise malfunctions may occur due to noise e e INSTALLATION PRECAUTIONS DANGER Before mounting or dismounting this module to or from the GOT always shut off GOT power externally in all phases Not doing so can cause a module failure or malfunction Before connecting the Bus connection cable to this module always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction CAUTION Use this module in the environment given in the general specifications of the GOT User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to GOT or screw damage STARTUP AND MAINTENANCE PRECAUTIONS DANGER Before starting cleaning always shut off GOT power Not doing so can cause a module failure or malfunction CAUTION Do not disassemble or modify any module This will cause failure malfunction inj
4. 0 0 35 1 This depends on the specifications of the Ethernet network system to which the GOT is connected For the details refer to the manual of Ethernet module you use 2 If multiple network equipments including GOT are connected within a segment the network load would increase In such condition the communication performance between GOT and PLC may be declined The decline of the communication performance may be improved by the following measures e Using switching hubs e Applying the high speed 100BASE TX 100Mbps for PLC and other equipments excluding GOT e Reducing the number of monitoring devices of the GOT 2 3 Specifications of the related devices Use the connection cable and the hub which meet the IEEE802 3 10BASE T standard Non shielded twisted pair wire category3 4 5 RJ45jack 10Mbps hub 3 Name of the Parts and Outline Dimension Drawing i fo y 2 gt oa O 4 gt D J Jal l 149 5 87 2 T S 30 2 1 19 Description Cable connection Connector for connection of cable connector GOT connection Connector for connection to the GOT connector EPs Aer transmit receive state of data O Off Flashing so RD Desoripton e No transmit receive data e GOT being reset 3 LED display e Communi
5. 0 Hz B Y and Z 61131 2 Incaseof 10 to 57Hz ___ 0 035 mm directions continuous for 80 vibration 97 t0 150 Hz 4 9 m s 3 minutes Shock Conforms to JIS B3502 IEC 61131 2 resistance 147 m s 3 times in each of X Y and Z directions Operating No corrosive gas atmosphere Operating 2000 m 6562 ft max altitude Inside control box category 1 level 2 1 Indicates the element in the distribution system between the public electricity grid and the mechanical equipment inside the premises that the relevant device is assumed to be connected to Category Il applies to devices such as those that draw their power supply from fixed installations The surge voltage withstand capability of devices with ratings up to 300V is 2 500V 2 This index gives a measure of the incidence of conductive materials in the environment in which the device is used A contamination level of 2 indicates an environment in which there is only contamination by non conducting materials but due to occasional condensation conductivity may occur 3 Please do not use or store A9GT J71E71 T in an environment with atmospheric pressure greater than the atmospheric pressure at sea level Om There is a possibility errors may occur if this point is not observed 2 2 Specification of the A9GT J71E71 T The performance specifications of the A9GT J71E71 T is shown below a ee specifications Internal consumed current 5VDC mA 50 Weight g Ib 16
6. INGAPORE 159943 Centro Dir Colleoni Pal Perseo Ingr 2 Tel 65 6473 2308 Via Paracelso 12 20041 Agrate B Thailand F A Tech Co Ltd Milano Italy 898 28 29 30 S V City Building Office Tel 39 039 6053344 Tower 2 Floor 17 18 Rama 3 Road Spain Mitsubishi Electric Europe B V Spanish Bangkpongpang Yannawa Branch Bangkok 10120 Carretera de Rubi 76 80 Tel 66 2 682 6522 08190 Sant Cugat del Valles Indonesia P T Autoteknindo SUMBER MAKMUR Barcelona Spain Jl Muara Karang Selatan Block A Utara Tel 34 93 565 3131 No 1 Kav No 11 Kawasan Industri France Mitsubishi Electric Europe B V French Pergudangan Jakarta Utara 14440 Branch Tel 62 21 663 0833 India Messung Systems Put Ltd 25 Boulevard des Bouvets F 92741 Electronic Sadan NO 111 Unit No15 Nanterre Cedex France M I D C BHOSARI PUNE 41 1026 TEL 33 1 5568 5568 Tel 91 20 712 2807 South Africa Circuit Breaker Industries LTD Australia Mitsubishi Electric Australia Pty Ltd Tripswitch Drive Elandsfontein Gauteng 348 Victoria Road PostalBag No 2 South Africa Rydalmere N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE 1 8 12 OFFICE TOWER Z 14F HARUMI CHUO KU 104 6212 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice Printed in Japan on recycled paper
7. MITSUBISHI A9GT J71E71 T type Ethernet communication module User s Manual Hardware Thank you for buying the MELSEC GOT Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL A9GT J71E71 T U MODEL CODE 1DM129 IB NA 0800199 D 0408 MEE MITSUBISHI Graphics Operation Terminal SAFETY PRECAUTIONS Read these precautions before using When using Mitsubishi equipment thoroughly read this manual and the associated manuals introduced in this manual Also pay careful attention to safety and handle the module properly These precautions apply only to Mitsubishi equipment Refer to the CPU module user s manual for a description of the PLC system safety precautions These SAFETY PRECAUTIONS classify the safety precautions into two categories DANGER and CAUTION Procedures which may lead to a dangerous condition and cause death or serious injury if not carried out properly CAUTION Procedures which may lead to a dangerous condition and cause superficial to medium injury or physical damage only if not carried out properly eo ee eS m Depending on circumstances procedures indicated by CAUTION may also be linked to serious results In any case it is important to follow the directions for usage Store this manual in a safe place so that you can take it out and read it whenever necessary Always forward it to the
8. cation driver for Ethernet connection has not been installed into GOT Data being received __ o Data being received O Data being transmitted Data being transmitted received 4 Slot cover Metal fixture that covers a slot for mounting Bus connection board should be removed when using Gateway function 1 The bending radius R1 standard value in the proximity of connector should at least 4 times the external of the cable 4 Installation Procedure 4 1 When using the bus connection board only when using Gateway function How to mount the bus connection board is shown below 1 Loosen the mounting screws 2 pcs that fix the slot cover on the back of the A9GT J71E71 T 2 Remove the slot cover Save the removed slot cover carefully If the A9GT J71E71 T is used alone without the slot cover foreign matter will enter the unit causing a failure or malfunction Slot cover N Bus connection z board 3 Fit the bus connection board to the A9GT J71E71 T 4 Tighten the mounting screws 2 pcs of the bus connection board to the specified torque 36 to 48N cm to fix the bus connection board 5 After fitting the bus connection board mount the A9GT J71E71 T to the GOT 4 2 How to mount the A9GT J71E71 T to the GOT Mount the A9GT J71E71 T to the GOT as follows 1 Fit the communication module securing fixtures in the GOT main unit
9. product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Ryoden Automation Ltd 500 Corporate Woods Parkway Vernon 10th Floor Manulife Tower 169 Electric Hills IL 60061 Road North Point HongKong Tel 1 847 478 2100 Tel 852 2887 8870 Brazil MELCO TEC Rep Com e Assessoria China Ryoden Automation Shanghai Ltd Tecnica Ltda 3F Block5 Building Automation AV Paulista 1471 Conj 308 Instrumentation Plaza 103 Cao Bao Rd Sao Paulo City Sao Paulo State Shanghai 200233 China Brazil Tel 86 21 6475 3228 Tel 55 11 283 2423 Taiwan Setsuyo Enterprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd RD Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea HAN NEUNG TECHNO CO LTD Tel 49 2102 486 0 1F Dong Seo Game Channel Bldg U K Mitsubishi Electric Europe B V UK 660 11 Deungchon dong Kangsec ku Branch Seoul Korea Travellers Lane Hatfield Herts AL10 Tel 82 2 3660 9552 8XB UK Singapore Mitsubishi Electric Asia Pte Ltd Tel 44 1707 276100 307 ALEXANDRA ROAD 05 01 02 Italy Mitsubishi Electric Europe B V Italian MITSUBISHI ELECTRIC BUILDING Branch S
10. uries or fire Do not touch the conductive areas and electronic parts of this module directly Doing so can cause a module malfunction or failure Exercise care to avoid foreign matter such as chips and wire offcuts entering the module Not doing so can cause a fire failure or malfunction Always secure the cables connected to the module e g run them in conduits or clamp them Not doing so can cause module or cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the module Doing so can cause module or cable damage or a malfunction due to a cable contact fault Before handling the unit touch a grounded metal or similar object to discharge the static electricity from the human body Failure to do so may cause the unit to fail or mulfunction DISPOSAL PRECAUTIONS CAUTION When disposing of the product handle it as industrial waste Manuals The following manuals are relevant to this product Refer to the following list and order the required manuals Detailed Manuals Manual No A985GOT A975GOT A970GOT A960GOT User s SH 4005 Manual Available as option 1DMO099 A950GOT A951GOT A953GOT A956GOT User s SH 080018 Manual Available as option 1DM103 Relevant Manual For relevant manual refer to the PDF manual stored within the drawing software 1 Overview This User s

Download Pdf Manuals

image

Related Search

Related Contents

Health & Safety Policy  Tripp Lite 7-Port USB 3.0 SuperSpeed Hub with Dedicated 2A USB Charging Port    FT- Décireur [Mode de compatibilité]  QGIS User Guide - OSGeo Server  E71 CONTENIDO  Fortran-90  

Copyright © All rights reserved.
Failed to retrieve file