Home

RU+5 EN.cdr

image

Contents

1. P10 last 3 adjusttheoutputintensify 0 5W weak 5 0W strength 4 adjust the photon mode synchronous turn off 5 Click Time on the screen and set working time 20 min every part 6 click the start kev to start the machine 7 clean the parts and applied gel on fleshy parts eg gel or essence The amount depends on moving flexibility of the ultrasonic slimming head Beautician hold the ultrasound head to move slowly on skin and do not stay unmoved on any part of your body while using ultrasonic cavitation slimming head 8 adjust the needed mode operational time and output intensify according to the treatment After finish click the exit 9 Clean the leftovers with hot towel use warm towel to clean the ultrasonic cavitation slimming head Fig6 1 as the screen shows picture 1 click the M80 key and get into the work as the picture 6 shows 2 choose the working model P1 P4 pulse P5 last 3 adjust the output intensify 10W weak 50W strength 4 Click Time on the screen and set the working time 10 15 min every part then applied gel on fleshy parts eg abdomen hip thigh The amount depends on moving flexibility of the ultrasonic slimming head 5 Click start put the foot switch under your feet step on to start working move away for pause 6 Beautician hold the ultrasound head to move slowly on skin in circle or beeline repeatly the other hand push the fat towards the ultrasonic cavitation slimming head
2. 7 Do not use on back avoid using on bones 8 Do not use on uterus part when women do abdomen care Abdomen treatment during menstruate should be avoided 9 The machine will pause automatically if the setting time is over 10 Clean the leftovers with hot towel use warm towel to clean the ultrasonic cavitation slimming head 1 Applied enough gel on skin need treated 2 Do not stay unmoved on any part of your body while using ultrasonic cavitation slimming head do not stay on bones and used in the human body heart throat and eyelids If the skin is sensitive or becomes unhealthy the strength of the power should be adjusted down 3 The daily treatment should be within 30 minutes 4 There will be ultrasonic only when you step on the foot switch 5 Do not make the RF electrode stay on any part without moving The electrode can not allowed to be placed under the state of no load to avoid the damage caused by high heat 1 Click 8 polar RF vacuum enter interface as Fig 7 2 Adjust output intensity 0 weak 10 strong 3 Adjust vacuum intensity 10KPa weak 100KPa strong 4 Choose vacuum mode as Fig 8 P1 P6 PE l P1 P5 vacuum mode has default times Need to adjust inspiratory releasing air time 2 P6 mode has no adjust function 8 Can set vacuum mode by yourself 0 1S 3 0S 4 When finish setting click return 5 Adjust times Cabout20minute Fig8 6 Nursing parts daub wipe essential oils or massage oil click
3. WL SO1 Multipolar RF Instrument User manual CONTENTS Catalog Warning Parts introduction Annexes Opearation Eyes care Facial care Body care de fatting Body care Thin body styling Others Note Forbidden group Technique parameters Annex List Warning Dear user Thanks for using our company s products in order to fully make use of the products we sincerelv suggests follow Please read this instruction in detail and keep it well for further reading and consulting tPlease follow the instruction to fit and operate the machine correctly e Please do not remove and change any accessories of the machine e It forbids others to open and remove the mainframe except the authorized people inthe company It forbids others to change and maintain the machine except the professional people e Please contact us if there is any trouble during operation 2 polar RF face handle 3 polar RF body handle M38 high frequency ultrasonic handle A D ww 8 polar negative M80ultrasonic handle Foot switch pressure handle 1 Connect the accessories to the host Insert RF 2 polar operating head to 4 2 Insert RF 2 polar operating head to 5 Insert M38high frequency waves operating head to 6 insert 8 polar vacuum operating Head to 7 Insert foot switch to 8 Insert M80 ultrasonic to 9 2 Insert p
4. ower line to 11 open the General power switch to 10 enter interface as Fig1 3 insert IC card correctly otherwise enter interface as Fig2 1 In interface such as Fig 1 click the 2 polar for face to enter interface as Fig 3 2 click lt and gt regulate output intensity of RF 1 weak 3 strong 3 click on and to set working time facial care about 20 30 minutes 4 Click on START begin to work click pause stop to work 5 Apply gel on face around skin move in circle the electrode probe move from inside out operating on both side right and left one side over to start to other side and must lower the intensity accordingly as less fat on forehead and eyes do not let gel into eyes 6 When it finished click EXIT 1 Click tri polar RF for body in interface as Fig 1 enter interface as Fig 4 2 Adjust output intensity 1 weak 10 strong 3 Setting treatment time about 20 30 minutes for each part 4 Click start to work click pause to stop 5 Put enough gel on treatment body part recommended high intensity on fat stock up part 6 When it finished click EXIT 2 polar RF for facial enter 3 polar RF for 2 polar RF for facial enter 8 polar vacuum for body work time 66 2 polar RF for facial Fig4 1 as the screen shows Fig1 click the M38 key and get into the work as Fig5 2 choose the working mode P1 P9 pulse
5. rhagic disease trauma or who is bleeding 4 Pregnant women 5 Medical Plastic parts or parts with artificial in filling inside 6 People with metal inside the body include metallic tooth 7 Patient with skin inflammation or with edema 8 People with an abnormal immune system 9 Numb or insensitive to heat Voltage AC110V 220V 50 60Hz Power lt 100W Output RF 5MHz Output ultrasonic 40KHz 1MHz Negative pressure 100KPa 1 Host 2 Power line 3 User manual 4 Bipolar RF handle for facial 5 Tripolar RF handle for body 6 M38 ultrasonic handle for facial 7 M80 ultrasonic handle 8 8 polar RF amp vacuum 9 foot switch 10 accessory frame 11 white fast connection sealing ring 12 Hexagonal screws 13 Hexagon wrench 1set 1pc 1copy 1pc 1pc 1pc 1pc 1pc 1pcs 1pc DPCS Spc 1pc
6. start Set time arrived instruments will be automatically suspended press any key to continue working 1 Need to apply oils or massage oil on the skin as convenient to move for another avoid the skin because of dry and feel pain 2 Adjust the negative pressure suction depends on the strength of the guest when should be determined by weak gradually stronger 3 Do not operate on the broken skin Click setting in interface as Fig 1 Click multimedia enter interface as Fig 7 insert USB to 1 insert headphone to 3 Q Click basic setting enter interface as Fig 8 Notes advanced setting is for manufacturer B MULTIMEDIA MOVIE MUSIC PHOTO PHOTO amp MUSIC RETURN Fig9 Fig10 1 Wear insulated gloves during operation 2 Do not wear any aglet both for the beautician and the users 3 The electrode probe must be fully in contact with skin 4 Do not make the RF electrode stay on any part without moving keep it moving on skin slowly 5 Skin around eyes and forehead is very thin the RF output intensity should be relatively weakened 6 Clear the filter cup after use Cleaning Methods Put some paper at the bottom of the filter bottle rise the valve with your fingers let the oil leak 1 People with heart disease or high blood pressure or configured cardiac pacemaker 2 Patients with acute inflammation asthma deep vein thrombosis thyroncus cancer 3 People with hemor