Home
        Installation Guide
         Contents
1.       1 2 Piscatus3D modes    Piscatus3D is available in two different modes   Inshore Pro and Deepsea Pro  It is important  to understand the differences between these modes and how the modes overlap  Please  refer the table below to compare the available modes  Inshore Pro produces the highest  detail of the seafloor because of its finer data resolution and depth accuracy  Deepsea Pro  is a more efficient system by storing less data it is able to maintaining bigger map sizes in       Piscatus    Version 5 Installation Guide 7                                                 deeper waters  For most vessels Inshore Pro is the current choice  as it can give higher detail  in shallow water but still stores data down to 3200 metres  Deepsea Pro is recommend for  vessels working almost constantly over 1000 metres or require 3D maps larger than 20 Nm   Feature Inshore Pro Deepsea Pro  Data resolution 2 4 metres 20 metres  Depth accuracy 0 1 metres 1 metre  inimum depth O metres O metres  aximum depth 3200 metres 32000 metres  inimum map size 1Nm 5 Nm  aximum map size 20Nm 60 Nm  Best performance  lt  1000 metres  gt  1000 metres   lt  1000 metres High detail Good detail   gt  1000 metres Small maps  detail same High detail  larger maps  as Deepsea Pro                   1 3 How Piscatus3D works    There are five main software elements that make Piscatus3D work  These are        SMISealog    Shared Memory    SeaDBLog      Firebird Database Server      Piscatus3D    Figure 1 over the 
2.     From Line   allows the user to set the start point in the simulation  file based on its line number  The simulation will start from this  point each time the    Start SIM    button is clicked     Continue   allows the user to stop the simulation and continue  from where it stopped  The simulation will start from where it was  stopped when the Start SIM    button is clicked           Simulation  output options       These options allow the user to control the processing and output  of data  There are three options that are self descriptive  They are  used for simulations where data is being sent to another computer   device or comm port  Default   Process and don t send NMEA to  output  comm port            Simulation comm  output options       These options allow the user to control the flow of data being  sent out comm ports  These are used for simulations where data  is being sent to another computer  device or comm port   Default   Out GP and SD to same port           34    Piscatus  Version 5 Installation Guide          4 4 4 Playing preset simulations    SMISealog is installed with three built in simulations  These are useful for Piscatus3D  dealers for show room presentations and other situations where the system must be  viewed in operation but no real data is available     Preset simulations are available through the    SMISealog Control Panel    window under the     NMEA Processing    and    Preset SIMs    tab  Simulations are started by selecting one of the thre
3.   DATA  ad 10   15  COMPUTER SPEGIFICATIONS issan rece cirits do ec a sh 10  2 0 INSTALLATION INFORMATION          sscsssssscsssssssssessssssececsssesessssssssessssesessssececessssesessseseesenee 12  ZN TALLA ONPE o ed aos al 12   2D INSTALLATION MEDIA co 14   23  INSTALLAMON MODE birca adios 15  3 0 SOFTWARE INSTALLATION          ssssssssssssssscessssssececessesesessssesecsssssessssesecesessececessssecesssseeesens 16  SNA LN ASA e 16  3 2 RUNNING PISCATUS3D FOR THE FIRST TIME     OBTAINING THE PERMIT CODE                 19  4 0 CONFIGURATION OF SMISEALOG          cssssssssssssssesessssssesessssesessesecesessosecessssesesessesesessesees 21  A INTRODUCTION oo 21   4  PASSING SMISCAIOG sto Dacia dates neo dead tdo edi e o 21   4 1 2 SMlSealog quick setup       22          4 1 3 Viewing SMISealog Status      AD COMM PORTS  ANDINMEA nimeen E E REEE 24  4 2 1 Viewing INCOMING data cocinan 24  ADD SEUNG UP CON EEA EA E ESE 25  4 2 3 Listening to incoming data  29         4 24 Sending data isinisisi 25  4 2 5 Using the automatic NMEA setup feature 26  4 2 6 Selecting NMEA settings   occiso 26  4 2 7 NMEA CXQMPLES   sssssssssssssssssssssssssnsssssssssesssssssssssseeessseseuinss 27  4 2 8 Primary and Secondary depth data and GUtO SWItCH  vsssssssssssecssssssssnssssesesenssseesssnnsseesen 28  4 2 9 Filtering AG cesesscsscsessssssessssscsssncossssnscesesssvessscensssssesscdunsiaisesasessnsssesssutesssassasssssecesassssainacssnsnessseeasacseisit 29  4 2 10 Enabling    Setup Mode    to i
4.  Current Tide    tab  This tab displays the data used  to generate the tide value  and when it was last updated        30 Piscatus  Version 5 Installation Guide       4 3 3 Selecting a tide engine  check     SMISealog is able to calculate tide with three different engines  The first is the Piscatus3D  Tide Engine and is available worldwide with every installation of Piscatus3D        There are another two tide engines available which are able to produce better tide  calculations in European countries  these are TotalTide and Proudman  Both these tide  engines must be purchased and installed separately before they can be used in SMISealog   Please contact your local Piscatus3D dealer for details on obtaining a copy of these   tide engines        The TotalTide tide engine requires no extra settings to be selected before it begins  to provide tide values to Piscatus3D  But the Proudman tide engine requires you to select  the data and license files  which are in the Proudman installation directory           4 3 4 Setting a default tide station to always be used    This feature is only available when using the Piscatus3D tide engine  By default SMISealog  automatically uses the closest tide station in order to calculate the current tide value   The user can override this setting by manually selecting a default tide station        Open the  SMISealog Control Panel    window and click on the    Tide Adjustment    tab  and then the    Current Tide    tab        2  Inthe    Tide Optio
5.  Dealer Trial Full  Result Demo   Demo    Install Install                                  Piscatus  Version 5 Installation Guide       3 0 SOFTWARE INSTALLATION    3 1 Installing Piscatus3D  Note   make sure you are logged on as Administrator to do the installation     1  Place the Piscatus3D installation CD in the computer s CD drive  The setup program  should start automatically  however if Autorun is disabled on the machine you will have  to start it manually  To do this go to Windows Explorer and navigate to the CD drive  and double click on    SetupPiscatus5 exe  Microsoft Windows Vista will require the setup  program to be run as an administrator and will display a message to this point which  you must accept to start the installation process     2  The Piscatus3D installation window will  open  as shown to the right  Installation    Urna betas  gt   options can be set up on the window   Presos voto 118 Epa von chort Pe seman    ER 1 y     wenererte wmn  o he Misaone P     by clicking the    Advanced Options    tab    Saag ty om apes yee T  These options should not be changed FAN   r y     era meme cot GeForce IOO Yer gria  when doing a first install  as they control cast basil ran sh nace ais 4 08 muse ss  which components are installed  and all prom raton Lant     X   7 et oina DIR LAA AL erre  are required on first install  Reinstalling    tet oe cis    a pus    individual components can be helpful  after install if one component is found  to be faulty and must be r
6.  SMlSeaLog is a stand alone program separate from Piscatus3D  SMISeaLog picks out the  various NMEA sentences it has been configured to recognize such as depth  position   hardness and roughness  COG  SOG and net position  and writes these parametres to  Shared Memory  It also flags  or discards  errors in the incoming data such as an incorrect  position from the GPS  or the sounder coming offthe bottom and giving erroneous depth  values  Piscatus3D and SeaDBLog then both read the values from Shared Memory  If C Plot  Pro or SeaPlot Pro are also installed on the same computer  they can access Shared  Memory as well and use the parametres and values stored there  SMISealog also has a tide  calculation engine and calculates the tide based on GPS position and GPS date time   SMISealog then places this tide value in Shared Memory to be used by Piscatus3D and  SeaDBLog  Tide information comes from any of three tide engines  being the Piscatus3D   TotalTide or Proudman tide engines     Figure 1  The relationships and data flow between Piscatus3D elements       SeaDBLog writes depth  hardness and roughness information from Shared Memory  to the Piscatus3D database file  C   Piscatus3D Data BATHYMETRY FDB   The SeaDBLog  program runs as a background Windows service called the    Sealog Database    SeaDBLog  also creates trip logs  which are exported by the Map Manager program and can be  imported into the Fleet Manager program  Fleet Manager is sold separately and is used  by commerc
7.  each source is in NMEA0183 format and up to four NMEA0183 outputs are  required  This unit is wired up as follows with each data source and destination being wired  into the top of the unit  Each source is wired to pins 2    and 7     Each destination is wired  to pins 1 ground  and 3        Pin 2    Pin5     lt   x lt    gt           3_8 38  Device 1    Device 2    Device 3    Device 4  NMEAO183 NMEA0183 NMEAO183 NMEA0183          Piscatus  Version 5 Installation Guide 37       5 2 DM24    The DM24 is a more complex multiplexer designed to be used when up to four data  sources are to be merged  each source is in any format and up to four outputs in any format   The unit is wired up as follows  with each device and the DM24 being plugged into the  DM22 4 Junction Box  The incoming data comes into the junction box  out to the   DM24 where it is converted and merged  back to the junction box and out an I O port   standard setup   I O 1         EBLO MAN    8089    zawa      9 LOVIAN  y 3080    88 LOWSWN  Mey    68 10V3NN     Boag       o  3    gt           38 Piscatus  Version 5 Installation Guide       5 3 How to convert Furuno CIF to NMEA0183 with a DM24    The conversion of formats is done in the DM24 using two dip switches  In the following text  switch states are described as 0 or 1  where 0 represents off and 1 on   Dip Switch 1       Dip Switch 2    The first thing to do is to plug the devices into the DM22 4 Junction Box  The important  thing here is to plug the Furuno 
8.  echo sounder and  also keeps data within the limits of the Piscatus3D 3D system        Echo sounder  Depths       This filter compares incoming data with recent data points and   is designed to filter out erroneous data points  such as a double  echo  It generates an average for the last x points and allows for an  error of y  if the new data is outside the range of y for z readings   the average is reset using new data  The default settings for this are  X 5 Y 50and Z 10        Depth offset    This setting allows you to set how far under the water line your  transducer is  When a depth is received from your echo sounder  this distance is added        Net height    This filter works in the same way as the above filter but on the  net height from seabed data  X   3  Y   10 and Z 5        Net depth    This filter works in the same way as the above filter but on the  net depth below sea level  X   3  Y   20 and Z 5        Cleaning level       When each point is added to the database it is compared   against points around it  By default this is on the normal setting    If you struggle with bad data from your echo sounder try the   high setting  Database cleaning can also be stopped by setting the  cleaning level to none                 Piscatus  Version 5 Installation Guide 29       4 2 10 Enabling    Setup Mode    to ignore GPS position problems    SMISealog is normally configured with the vessel at the wharf Dock  As the vessel is not  moving SMISealog will flag the data as ha
9.  receiving data for a set time and using the highest count values of received NMEA strings to    select the best settings  To access this automatic NM    Control Pane       window  click the    NMEA Processing ta    EA setup feature  open the  SMISealog  b and then the    System    tab  and then    click the    Auto detect NMEA Settings    button  Before starting the automatic NMEA setup    feature make          ON and send    for information on viewing incoming data     4 2 6 Selecting NMEA settings    All data sent  each line con  MEA strings  he NMEA da  MEA strings  Piscatus3D wil    o Piscatus3D must be in NMEA format  This format      but needs to know which ones to expect  This m  listen for dependin       WO parts   a    For example   is SDDBS        Setting the correct comm port an    alker and a data type     depth data has a tal       done by a marine electronics technician     Roughness and hardness N    Furuno echo    offset values that can be ente    and SeaScan  allows you to    The    Net NME    equipment  With these data  P  terrain  for more effective fish    system you h  may need to    sounders  or SeaScan or RoxAnn seafloor di       fferent values for the same  fferences between units w    units give out di  correct these di    type o  hen da          A tab has options for setting up Piscatus3D to liste  iscatus3D can put your net    ing  There are options to se             sure all marine electronic devices sending data to Piscatus3D are switched  ing da
10.  seabed discrimination device  if present   Instructions for  configuring SMISealog are outlined in section 3 0     13  If you are outside New Zealand it is possible that you will be supplied an extra    Back   ground relief data    CD inside the installation pack  This installs land and seabed data for  your area  if available   Please install this data before using Piscatus30     3 2 Running Piscatus3D for the first time   obtaining the Permit Code    Piscatus3D uses a dongle and a special code  referred to as a Permit Code  for its security and  licensing  If your local supplier does not have a dongle in stock a 60 day trial can be installed  and used without a dongle  This gives you a window of time to organise the delivery of   a dongle  so that your Piscatus3D system can be permanently used  Please give you local  supplier as much notice as possible to avoid purchasing a Piscatus3D system when no  dongles are being held in stock     To obtain the Permit Code to licence Piscatus3D and operate the software you need to  contact Seabed Mapping and provide us with the Computer ID of the machine you are  installing Piscatus3   on        Piscatus  Version 5 Installation Guide 19       1  The first time you run Piscatus3D after installation the    Computer Identity    window will  open  as shown below        Computer Identity  To register your copy of Piscatus pleare send us the identity code displayed below     We will then forward back your Permit code to enter   Your compute
11.  the  SMISealog Control Panel    window and click on the    Tide Adjustment    tab and   then the    Graph tab  This tab will automatically show the current tide station being used  but different tide stations in the area can be viewed by selecting them from the drop down  box  Tide stations for other areas can also be displayed by searching for them using the  lookup feature on the    Lookup    tab described above     4 4 Simulations   4 4 1 Recording simulation files   SMISealog can be set up to record simulation files in the    System    tab of the    NMEA   processing    tab  These simulation files record the raw NMEA data being received by  SMISealog and using the simulator in SMISealog can be played back and sent into    SMISealog again     1  To start recording a simulation file open the  SMISealog Control Panel    window   and click on the    NMEA Processing    tab and then the    System    tab           2  Inthe NMEA Log Files    section  tick the    Record NMEA log    option  Optionally specify  a date when you wish the recording to cease at        3  Underneath this option there is a setting that allows you to control the amount of NMEA  data recorded  We recommend    Every line    be used  However  for users with little hard  drive space the recording of simulation files over a week or more can create some rather  arge files so this frequency can be changed to conserve hard drive space     4  Recorded simulation files are stored on the hard drive in the C  Piscatu
12.  you are missing important data you may have to customize your NMEA or filtering  settings  Please check    Selecting NMEA settings    and Filtering Data    sections of this manual for  further assistance     9  Start Piscatus3D  If all required data is shown in the Incoming data    window   start Piscatus3D  Piscatus3D should detect the data and load a 3D seabed for around  the boats current position  when this happens the    Follow boat    option in the bottom  left of Piscatus3   will be ticked     4 1 3 Viewing SMISealog Status    The    System first tab under the    NMEA Processing    tab of the  SMISealog Control Panel     window gives you a quick summary of SMISealog s current status        The top section called    Current Status    gives you a live update of the most important data  values being used by Piscatus3D  All these data values and the data status readings are  important for Piscatus3 to work correctly  Also displayed here is the status of database    ogging and trip logging     The bottom section called    Setup Tools    gives you an option to open a virtual keyboard for  users of Piscatus3B with touch screen displays  This virtual keyboard can be used anywhere  in Windows to enter text  A user can also restore factory settings and perform an automatic  MEA setup        4 2 Comm ports and NMEA  4 2 1 Viewing incoming data    To view the incoming data  open the  SMISealog Control Panel    window  click the    NMEA  Processing    tab and then    Terminal    t
13. 3D successfully are outlined below   However  for performance reasons  we strongly suggest you obtain a system that  encompasses the recommended requirements     Recommended system requirements     Intel   Pentium   Dual Core Processor 1 8 GHz  1024 MB of DDR RAM   GeForce 6 series 256MB   nVidia Video Card essential   80GB 7200 RPM Serial ATA Hard Drive  Screen Resolution 1280 x 1024       Piscatus  Version 5 Installation Guide 11       The installation process of Piscatus3D can be undertaken in many different ways  This section  will explain some of the options and help to remove any uncertainties     2 1 Installation types  1  User demo   2  Dealer demo   3  Trial installation   4  Full installation    ITEM    1 User demo  installation    2 Dealer demo  installation    DESCRIPTION    The user demo version on the brochure disk will install  without a dongle    It will display pre loaded bathymetric data    It won t record input from a sounder or GPS    It can be installed on multiple computers    It will expire 60 days after installation    It can t be loaded back onto the same computer    The dealer demo version will install from any Piscatus3D  installation CD    It requires the special demo dongle to run    This will allow dealers and distributors to demonstrate  Piscatus3D on an ongoing basis  either in a showroom   office or from a laptop    It has the same functionality as the user demo except that it  will not expire after 60 days if installed correctly and enabled  
14. CIF signal into I O 2  which is the same position as Device 2  in the diagram at the start of this section     Now you must set the dip switches in order to convert the signal format  First take the top  of the DM24 unit  There are four switches on dip switch 2  set them all to 1  There are eight  switches on dip switch 1 from 1 to 8 set each switch as follows  00100000  Turn the DM24 off  and on to save the new settings     To test the DM24 conversion turn on only the attached Furuno CIF device and watch the  SMISealog    Terminal    window to ensure the correct format data is being received        Piscatus  Version 5 Installation Guide 39       dd    Improve your fishing experience  and results with Piscatus3      CONTACT INFORMATION    Piscatus Limited   Port Nelson   New Zealand   P  64  0 3 545 7020   F  64  0 3 545 7021   E support piscatus co nz  W www piscatus co nz    PISCATUS3D    UPEWIGH SEAR y                   
15. ENSE     GPS  Echo Sounder  Simrad ITI  via multiplexer x Y   NMEA 0183   Creation of marks  vessel tracks Y Y  Trial  60 days  available  Y Y  Physical dongle required for permanent Vi wi  installation   Permanent Storage of instrument inputs   including navigation and other data  x Y  in program database  Permanent storage of marks  vessel track in Es 7  program database  2 2 Installation media  ITEM DESCRIPTION  A  Piscatus3B version 5   To install full options     Classic  Inshore Pro   installation CD Deepsea Pro  To install 60 day trial version without need  for dongle  B Demo installation  amp    Contains Piscatus3b demo installation  amp   promotional movie DVD background relief data     Contains video presentations with audio    in English     C Background relief data CD   3D topography data installation CD   relevant to area of customer      Supplied separately with Item A above for    you only   Dongle USB security key  Demo or Full   E Installation pack Box  sleeve  Quickstart guide  user manual     installation manual       Piscatus  Version 5 Installation Guide       2 3 Installation model                                                       Step 1   The Disk aude       Step 2   Install Type El         Step 3  Demo    Installed App E O    Full                                                       ra A ra A  Step 4  Demo    Demo Trial Full  License 60 day    Dongle    60 day   Dongle   Ory   Step 5    Trial Full  Permit   Permit    Permit   y y y y  Step 6  User
16. Start SeaDBLog Service  SMISealog has to be manually  restarted via the Windows Start Menu  Firebird must be started through Windows Services  in the Administrative Tools section of Control Panel                 Piscatus  Version 5 Installation Guide 35       Check data being received and processed    If the bottom right light in Piscatus30 is flashing or solid red check SMISealog is receiving  and processing the data correctly through the    Terminal    or Comms tab of the    SMISealog  Control Panel    window  When viewing incoming data check for position and depth data  and data lags being issued     Check Shared Memory in Piscatus3D    If data is being correctly received and processed in SMISealog check that  Piscatus3D is receiving this data  To do this  go to the Help menu and select  Support   System Information  Click on the    Shared Memory    tab and click the     Auto update    option so it is checked  The values being sent to Piscatus3D from  SMISealog will be displayed  Check these values against the incoming data   in SMISealog to make sure they are the same        36 Piscatus  Version 5 Installation Guide       5 0 USING MULTIPLEXERS    Multiplexers are used to merge incoming data from multiple sources into one data stream   We recommend the MX4 and DM24 data multiplexers available from Pacific Micro Systems   http   www pacmicro com products html     5 1 MX4    The MX4 is a simple multiplexer designed to be used when up to four data sources are   to be merged 
17. Version 5 0    Installation Guide          PISCATUS    Piscatus3D delivers a real time 3D view of the ocean floor anywhere in the world   helping you to make the best decisions to catch more fish faster           Version 5 0    Installation Guide    Congratulations on your purchase of Piscatus3D    Piscatus3D is a comprehensive 3 Dimensional fishing tool that displays in  superior detail  exactly what is happening underwater in real time as you  fish  With an interface designed by fishermen for ease of use  view your  underwater fishing grounds as never before  Piscatus3D shows your boat  the  seabed  the target fish and your fishing gear  Built on a stable and reliable  technology platform  Piscatus32 automatically saves your data as you fish   Piscatus30 is available in three customised applications designed specifically  for your fishing operations  Inshore Pro  Deep Sea Pro and Piscatus3D Classic           PISCATUS             Piscatus  Version 5 Installation Guide       8     LICENCE TERMS    The Piscatus3D software  the Software   has not been designed as  nor purports to be   a navigational aid and must not be used or relied upon as such by the user  The Software  is supplied solely as an aid to fishing not an aid to navigation     The software is supplied on the express condition that Piscatus3D Limited accepts no  liability for any loss of catch  failure to catch  loss of life  personal injury  or loss or damage  to any vessel or fishing gear resulting from the use o
18. ab  The control on the left called    Display Input    is where  you select the comm port you wish to view data coming in from  The control to the right   is a where the associated incoming data is displayed   this control is black and will display  lines of incoming NMEA data with white text  Sometimes these lines of data will appear very  quickly and must be paused in order to be read  To pause the incoming data click the    Pause     button at the bottom of the window        For example  to view data coming in from comm port 3    Left click on the    Comm3 option in the    Display Input list  When this option   has been checked data from comm port 3 will be displayed on the right hand black  data display area        24 Piscatus  Version 5 Installation Guide       4 2 2 Setting up comm ports    To set SMISealog to listen for incoming data  open the  SMISealog Control Panel    window  and click the    NMEA Processing    tab and then the Comms tab  Comm ports can set up to  listen for  or to send data  From the    Comms tab the baud rate  speed  of data being sent  or received can be set and whether or not incoming data should be checksum validated   There are also options to completely stop start data comms and database logging     Note   data cannot be read and sent from the same comm port  In order to read and send data  you must have a minimum of two available comm ports     Setting the correct comm port and NMEA settings can be complicated and should only  be done by a m
19. arine electronics technician     4 2 3 Listening to incoming data    To listen to incoming data from a specific comm port  open the   SMISealog Control Panel     window  Click the    NMEA Processing    tab and then the    Comms tab and click on the required  comm ports name from the list on the left entitled    read input from  Max 5 ports   A tick will  appear to the left of the comm port s name to indicate that SMISealog is listening to this  comm port for data  Up to five comm ports can be selected to receive data     4 2 4 Sending data    Data can be sent from SMISealog out a comm port  For example you can send data to a  CNBX that is using the SmartNet system  send data to another PC or device  or send data to  another comm port for another application     To send data from a specific comm port  open the  SMISealog Control Panel    window   Click the    NMEA Processing tab and then the    Comms    tab and click on the required comm  ports name from the list on the right entitled    Send output to  Max 2 ports     A tick will  appear to the left ofthe comm port s name to indicate that SMISealog is sending data out  this comm port  Up to two comm ports can be selected to send data           Piscatus  Version 5 Installation Guide 25       4 2 5 Using the automatic NMEA setup feature    The automati  SMISealog an    c NMEA setup feature is designed to lis  d automatically set all NMEA string sett    ten to the data being received by  ings  It does this by listening to the   
20. d data to Piscatus3D     This includes equipment like GPS  echo sounder and data multiplexer  Check data  cables are correctly plugged into PC serial rs232 comm ports        2  Check for data in terminal  Open the  SMISealog Control Panel    window by left clicking  on the SMISealog icon and selecting the    Control Panel    option  In the window that  opens  click the    NMEA Processing    tab and then the    Terminal    tab  Select different comm  ports from the    Display Input    list  Data will appear as white lines of text against the black  background  each line will normally start with the   character  Note down a list of which  comm ports display data     Example data string   SGPGGA 212812 4107 138 5 17423 858 E 1 7 2 1  1 M 19 M         22 Piscatus  Version 5 Installation Guide       In the  SMISealog Control Panel    window  click on the    NMEA Processing tab and then   the    Comms tab  In the    Read input from  Max 5 ports  list  tick each of the comm  ports  for the appropriate input comm port as noted in Step 2  Finally tick the    Enable Comms     option to start data processing       The quickest way to set up your NMEA processing options is to open the    SMISealog  Control Panel    window  click on the    NMEA Processing    tab and then the    System    tab   and in here click the    Auto Detect NMEA Settings    button  This process will monitor all  incoming data for thirty seconds then automatically select the best options  In the     Net NMEA tab you 
21. e  simulation buttons and stopped by pressing the    Stop SIM    button  As when playing  simulation files the speed of the simulation can be changed by reducing or increasing   the line delay     4 5 Fault Finding   4 5 1 Restoring factory defaults   If SMISealog settings have been modified and SMISealog will not work correctly  restoring  factory settings may help  This will restore comm port  NMEA  filtering and tide settings   Once factory defaults have been restored all settings would have to be adjusted to the users    setup again     1  To restore factory defaults  open the    SMISealog Control Panel    window  click on the     NMEA Processing    tab and then the    System tab           2  In here  click the    Restore Factory Defaults    button   4 5 2 Finding problems    If Piscatus3D does not seem to be working correctly please check all of the following   These checks are written at a marine technician level and do not give every detail  on fixing the problem     Check services    n the bottom left of Piscatus3D there are six lights  All six lights should be green for  Piscatus3D to be working correctly  If one or more light is not green place or mouse over  he light and you will get a short message of the problem  SeaDBLog can be restarted   in Piscatus3D through the Help   Support   System Information window  In the    System  nformation    window that opens  click the    Database    tab and in here you will see buttons  called    Stop SeaDBLog Service    and    
22. ecting into a boat s GPS  sounder and seafloor  discrimination device  a database can be built of the seabed s depth  hardness and  roughness from the area the boat fishes  Depths are then used to build a model of the  seafloor and hardness and roughness characteristics are overlaid  By getting accurate maps  of the seafloor instantly  a fisherman can increase the boat s efficiency markedly     Seabed Mapping  Piscatus3 Ltd  is run by ex commercial fishermen and it is a policy that  all our staff spend time at sea on commercial fishing boats  Our experience and close  association with the commercial fishing industry helps us to make our products as useful  as possible and easy to use for fishermen  We understand that fishermen want to catch fish  and not learn about computers                 Piscatus3D can interact with the boat s plotter via a component called Shared Memory   At the moment C Plot Pro and SeaPlot Pro are supported  If a different plotter is used please  contact Seabed Mapping and we can see if we can integrate with it as well        This manual details the background components of Piscatus3D  what they do and how they  all work together  the software installation procedure and the configurations necessary for   the Piscatus3D system to work with the boat s electronic equipment  This manual assumes a  reasonable level of understanding of a PC  windows and marine electronics  Please consult   the Piscatus3D user manual for learning how to operate the software  
23. eplaced    To continue press the    Next    button        Reial   Rar uti Tex    ne      3  Onthe Install   tab there are two options   Select    Install Piscatus3D Version 5     to install the full working version of  Piscatus30  Or select    Install Piscatus3D  Version 5 Trial   to install a 60 day version  which also has full working functionality        Note  Trial installations can be converted to  full installation after 60 days by purchasing  a dongle and requesting a new full version  permit code  But please be aware that the  system will not run once the 60 days has  expired and that there may be some  downtime before a dongle is received           16 Piscatus  Version 5 Installation Guide       4  Once either the full or trial install option has been selected the installation will start   This installation installs all required parts of the Piscatus3D system  You will now be asked  if you want to proceed with the installation on your local drive  as shown below  select  Yes  The default installation directory for Piscatus3D is C  Piscatus3D        A AQ        O Setup 1 now red te tal Pacatus to your lacal dive  De you wsh to vente   ie j h    5  The first thing to be installed on your  Open Fle   Security Waring    computer will be Firebird Database The palidver cesta pol bo varied  fen gus aun pee want bs  server 2  You may be displayed with RA  g y p y A 1  Ima ktopinetaevertea  rt meta pre  a security warning before installation pu Brata innam Publio  E   Spa App
24. f the software     The licence entitles the user a single licence to use one copy of the Software installed  on a single terminal        The sole entitlement of the user is as a licensee of the Software for the purposes  of the user only     Piscatus3D retains sole and exclusive copyright of the Software and written material  supplied and neither the Software itself nor any written materials supplied with the  Software may be copied by the user  or made available to  or used by  any other person  in any manner     All other rights are solely reserved to Piscatus3D Limited     Piscatus3  Limited s liability in respect of the Software is entirely limited to any  performance failure relating to the Software itself when operated strictly in accordance  with operator instructions  Piscatus3D Limited s liability is solely limited to a refund of the  purchase price of the Software  In particular no liability is accepted for any failure caused  by the operating environment in which the Software is installed or used  any  consequential loss or damage incurred by the user or any third party  the  consequences of any installation or reconfiguration of the user s operating environment  by the distributor of the Software  All warranties implied by the law of any jurisdiction  are excluded to the maximum extent possible              Piscatus3D Limited accepts no liability whatsoever for any failure  breakdown  or incompatibility of any related hardware supplied by its distributors or deale
25. ft  Display incoming data click on the small white and red fish icon  From this menu you  Tide Graph can do simple tasks like starting and stopping tide adjustment   v Start Tide Adjustment viewing the current tide graph or opening the  SMISealog  Stop Tide Adjustment Control Panel    window  A picture of the SMISealog menu is  Help shown on the left     Shutdown SMISealog          Piscatus    Version 5 Installation Guide 21       The top option called    Control Panel opens the  SMISealog Control Panel window where  SMISealog settings are set and modified  as shown below     3   PMA Proceserg   tow Achmet   abortado    Syrien   Comme   feat NMEA   Boat MAMA    Niet hasta   Ferg   tet Fate   Tarrant   Pronat sats   Goma    Current States  GGeeog Simulation running Lact Ore 63 09 Cate Statue FID F254 y  Lat bae 007 131  S hast Date GP2D 070  21 20 14 DO kog Active  Last Long 171051  E Last Toe 03 Tre bog Disabled  Cors Enabled Los Disabled  MAA Log Pine  FT Record MEA to 2  F Sko recerting on date  ros     Mecrea  Frwy rom     aag loot       Coen atat  1  2 Caan rpt     The SMISealog control panel is designed using tab controls  There are two main tabs along  the top for NMEA processing and tide adjustment  Beneath each of these main tabs are  sub tabs that group different options available to the user  The status bar along the bottom  shows which comm ports are currently being used     4 1 2 SMISealog quick setup  1  Turn on all electrical equipment that has been wired to sen
26. gnore GPS position problems    30  4 2 11 Receiving ARPA target dt    30  NA e o e 30    4 3 1 How tide adjustments are calculated             4 3 2 Viewing current tide adjustment           30  4 3 3 Selecting a tide engine  Check     31  4 3 4 Setting a default tide station to always be USC    31  4 3 5 Viewing a list of available tide stations in YOUF Al   O    31  436 VIEWING THE TICES ARAN A on 32       Piscatus  Version 5 Installation Guide 5       JA  IMUATION S mainiota e Ae es oa acai Ae  lence A Ah tas etic ca antl 32       AA TRECOIGING sinulat ones e 32  4 4 2 Playing recorded simulation files essessssssssoosssssusssesssssssssssssssssssssessssisssssssssussassesesssnsssssssssnsesseses 33  4 4 3 Simulation Options                     4 4 4 Playing preset simulations    45  FAULT AND NG os ed e e e aE  45 LRESTOMNG LACTOIY CEIGUI ES 0  denen deme cae dot o abhi kaa deot bins dl cdo A are dl cb bd 35  BLAN problems ian A A ls 35   5 0 USING MULTIPLEXERS wssscsssscssocsssesestsnsssevenssscosssnsnssacsesbsvseseatonnsseosasastsescnstesvebstsbessenscscosseate 37   VEE A tee 37   DIM DAS e E nel tea bee ee E E EN 37   5 3 HOW TO CONVERT FURUNO CIF TO NMEA0183 WITH A DM 24 cacaos 39       6 Piscatus  Version 5 Installation Guide       1 0 INTRODUCTION  1 1 What is Piscatus3D    Piscatus3D is a computer program that makes maps of the seafloor or lake bed for  commercial and recreational fishermen  It has been designed to help fishermen   catch more fish in less time  By conn
27. ial fisheries to maintain a central database back at head office        Piscatus  Version 5 Installation Guide       Piscatus3D also reads Shared Memory to dynamically update the terrain model and boat  position in real time  Only when a new position is rendered does Piscatus3D fetch points  from the database     Piscatus3D Inshore Pro and Piscatus3D DeepSea Pro both install from the same set of  disks  The Permit Code you are given by Seabed Mapping when licensing the software  determines what mode Piscatus3D will run in and whether any additional modules   are activated     Navigator is another program that is opened from within Piscatus3D itself    This program gives the user an overview of the world with coastlines  boat tracklines and  high resolution global bathymetry maps  Piscatus3D Navigator is standard with all Piscatus3D  nshore Pro and Piscatus3D DeepSea Pro installations and does not require any extra  installation steps           SmartNet    is an add on module that can be purchased in addition to the standard  Piscatus3D system  It is a net positioning system that determines net location by matching  depths received from the net sounder with seafloor depths stored in the Piscatus3D  database  SmartNet    can be added on to any Piscatus3D DeepSea Pro installation    f you are doing a SmartNet    installation on a boat  please contact Seabed Mapping for  further details           1 4 Built in data    Piscatus3D comes with a built in background dataset called Pred
28. icted Bathymetry   that covers the planet  This data is a one nautical mile grid cell dataset based on satellite  altimetry  The dataset is kept separate from the boat s actual soundings and once the boat  has collected its own data the background data will be ignored where the owner s data   is present     Another type of background data is Piscatus3D relief data  These are high detail data files  available in some areas containing topographical and or bathymetry data for localized  areas  This data is typically used to draw land terrain for inshore and lake fishing  The data   is installed separately from the Piscatus3D background Predicted Bathymetry and is only  available in areas where either topographical or bathymetry data is available in the public  domain  Typically the precision of this data is around 90m and therefore may produce some  accuracy errors around the shorelines  Note however that boat data collected will always  override land data points present in same location        10 Piscatus  Version 5 Installation Guide       In some special cases supplementary data can be supplied as text XYZ data and imported  into the user database via the Map Manager program  This data may come from a number  of different sources including other Piscatus3D users  hydrographical offices and government  agencies  Instructions for importing this type of data can be found in the user guidebook     1 5 Computer specifications    The minimum system requirements for running Piscatus
29. log to listen to your NMEA strings  please try  the    Automatic NMEA setup feature  For information on this please refer to section 3 2 5        4 2 7 NMEA examples    Position  heading and speed    GPS   SGPGGA GPS position and time  SGPRMC GPS position and time  SGPVTG Speed and course over ground  SGPZDA Time and date   Gyro   SGPHDT Vessel heading   Depth   Sounder   SSDDBT Depth below transducer  SSDDBS Depth below sounder    There is an option on the    BOAT NMEA    tab to enable support for an old JRC NMEA format  with a leading    U    character     Hardness Roughness data                JRC JFC130   SPJRCS Hardness data   SeaScan   SPSAP Depth  Hardness and Roughness data  RoxAnn   N A Depth  Hardness and Roughness data       Piscatus  Version 5 Installation Guide 27       Furuno  SPFEC Depth  Hardness and Roughness data    Net information  When using any of the following please ensure that the correct net monitor is selected on  the    Piscatus30 Setup    window                       Simrad ITI   SIIGLL Net position   SIIDBS Depth below sounder   SIIHFB Trawl height footrope and bottom   SIITDS Trawl spread   Furuno CN22   SIIDBS Depth below sounder   SIMTW Temperature   Scanmar   SSMDBS Depth below sounder   SSMHFB Trawl height footrope and bottom   SSMTDS Trawl spread   Netview3D   SIIN3D Net position  depth  range  height and temperature  Pacha Geonet   SIISAL Net sensors range  bearing and depth  SIISAN Net sensors height  temperature and spread    4 2 8 Primar
30. ns    section at the bottom of the window  click the    Always use    option   then click the    Set    button     3  A message will pop up asking you to select the tide station to use  dismiss  this message by clicking the    OK    button  You will automatically be taken to the     Lookup    tab of Piscatus3   Tide     4  Click the    Set as default station    button     5  You will be returned to the    Current Tide    tab and you will notice that the tide station  you just selected is now displayed in the    Always use    box        4 3 5 Viewing a list of available tide stations in your area    This feature is only available when using the Piscatus3D tide engine  To view a list of available  tide stations in your area  open the  SMISealog Control Panel    window and click on the      Tide Adjustment    tab and then the    Lookup tab  Enter a latitude and longitude for your   area and click the    Lookup    button  The tide engine will search for tide stations around the       Piscatus  Version 5 Installation Guide 31       latitude longitude position entered up to the maximum range set  the default is 40 000  metres   The tide stations found to be within range of the latitude longitude entered will be  displayed  These tide stations can then be selected and set as a default tide station or their  tide values can be viewed graphically     4 3 6 Viewing the tide station graph    This feature is only available when using the Piscatus3D tide engine  To view a tide graph  open
31. oranien  of Firebird Database Server  as shown a FTAA ee ap eee  below  If displayed select    Run     Accept     or    Allow    Ba    I7 Aways ask betore opening Pws Me    This le coes nat have s valc doai sqnetre fuat verfiss te  ir You thosd sty an wins Som  gt  len you nat  lisy can   ceckse whut softeere Lo a     2    6  The HASP SRM Run Time Environment  RTE  is the next  component to be installation     a  If you are installing the full working version the  installation will ask you to insert you HASP dongle  once the RTE is installed  The window to the right Please insert your HASP dongle  will be displayed  This window will automatically  disappear and the installation will continue once the  dongle is detected  If you do not have the dongle at  this time select the    Cancel Search    button to continue    anehna bor HAS   Donda    the installation    Corcelfeacn         b  Ifyou are installing the 60 day trial version the installation will ask if you wish to have  a 60 day license  Select YES to this question  Please note that this 60 day license  cannot be un installed or re installed       Piscatus  Version 5 Installation Guide 17       7  Next the Piscatus3D application will  be installed  This is automatic and  no settings and buttons must be  touched  The process windows as  shown to the right will be displayed          eae vat oris Soe neah Wea Don yas comme       Swine tirs  Ciao ep rejes Ma T pro       8  The underlying data sets that come  with Piscatus3D 
32. page shows one possible setup of a Piscatus3D system and the flow of data  between the various Piscatus3D elements  In this example  data is given out from the various  bits of electronic equipment on the boat in NMEA format  Each of these data outputs are    fed into a Data Multiplexer  wh    ich combines all the NMEA sentences into one data stream     This data stream is then fed into the Piscatus3 gt  computer via a single comm port  This is a  common setup for vessels with more than two devices outputting data to Piscatus3D        Piscatus  Version 5 Installation Guide       Other possible Piscatus30 setup options are to receive the data via UDP using the  computer s ethernet port  or to send NMEA into multiple comm ports on the PC  thus  removing the need for a data multiplexer  UDP data is only available from some NMEA Data  Multiplexers or can be configured on another computer within the Piscatus32 computer s  network  This setup allows multiple data sources to be shared over an Ethernet network to  multiple computers and multiple programs per computer  Setting Piscatus3D SMISealog to  listen to NMEA from many comm ports is a good option for users only requiring GPS and  echo sounder data  but correct precautions should be taken concerning electrical isolation  and device earthing  Please contact your Piscatus30 dealer concerning electrical isolation  and device earthing with your installation        PC    oR Ret E elos           4 a    ott roy AE tenes oe       lt    
33. r s Kientfy code  email code lo seabed seabed co nz wih your details        Copy code to cipbeard   Copy code to dsk Emai entry code       Enter your Parmi code here       2  Please supply Piscatus3D Limited with the 32 digit Computer Identity code either  via email  Ssupport piscatus co nz   or through our website dealer login page   http   www piscatus co nz login htm   If you do not have internet access you can phone  us on  64 3 545 7020 or fax the code to  64 3 545 7021  We strongly recommend using  either email or the internet and copying and pasting the codes so as to prevent any  potential errors when copying them down     Other Information we require is the Piscatus3D mode  either Inshore Pro or DeepSea Pro    vessel name  and the company name the vessel belongs to  The latter is only used when   generating the Permit Code as Piscatus3D installations have encryption routines that take  into account the parent company to allow data sharing between vessels using the Fleet   Manager and Map Manager programs     3  Seabed Mapping will reply with a 64 digit Permit Code that should be entered in the  bottom text field of the above    Computer Identity    window  Once the Permit Code has  been entered  click the    Accept    button to continue  Piscatus3D will automatically load  after you have accepted the Licence Terms     4  Piscatus3   is now ready to use  Click the    Follow Boat    option in the upper left hand  corner of the screen and you will be taken to the curren
34. rs  or otherwise used to operate the software           This licence continues until terminated  The user may terminate the licence by   destroying the CD containing the Software and all written material supplied or  returning it to the retailer distributor from whom it was purchased  The licence  terminates automatically if the user is in breach of any provisions of this licence           Piscatus  Version 5 Installation Guide       9  If any provision in this licence is held to be unenforceable by any Court having  jurisdiction the rest of this licence will remain in full force and effect     10  This licence is governed exclusively by the laws of New Zealand  and constitutes  the entire agreement between the user and Piscatus3D Limited replacing the terms  of any purchase order  marketing material  communication  or any representation  by Piscatus3D Limited or any distributor retailer appointed by Piscatus3 Limited     ACCEPTANCE    The intending user of the Software has read the terms of this licence and by ticking the box  to install the Software accepts the above Licence Terms as exclusively constituting the terms  of use of the Software        4 Piscatus  Version 5 Installation Guide       1 0 INTRODUCTION ooconccococoonononononononononononononanononananonananarinanannononononononononononononononononononororranoririnanss 7          TIWHAT IS  PICA TU nas 7  1  2 PISCATUSID  MODE Sc 7   13 HOW PISCATUSO WORKS uine cia aNes eilacuaua ee a lain aaa otaiant 8   TWA BUNT IN
35. s3D Data   MEAlogs  folder Each simulation file is named based on its date created with  extension    txt  For example  a file created on August 31 2005 would be 31082005 txt             Note   for information on playing back a recorded simulation file please refer  to the section 4 4 2        32 Piscatus  Version 5 Installation Guide       4 4 2 Playing recorded simulation files    In order to play a recorded simulation file  NMEA settings must be correctly set  This section  of the manual only covers use of the simulation and not SMISealog setup     Te    To start a simulation open the  SMISealog Control Panel    window and click on the    NMEA  Processing    tab and then the    Simulation    tab     Click the       button  This will open an    Open file dialog box  use this to navigate to  and  select  a NMEA simulation file     Set the    Play Options  The play speed of the simulation can be adjusted by changing  the Line delay  m s   We recommend 100 m s  Increasing the line delay will slow  the simulation     Click the    Start SIM    button to start the simulation     Check the simulation progress  The simulation progress can be checked in two places   The first is the progress bar below the    Start SIM    button  this should be slowly filling as  the simulation file is played  Below the progress bar there is also a line count that should  be increasing     It is important to check the    Terminal    tab to make sure that simulation data is entering  SMlSealog  To do 
36. should select the type of net monitoring equipment  if any  used           ow check the incoming data  In the  SMISealog Control Panel    window  click the     NMEA Processing    tab and then the    Comms tab  and then click the Display incoming  data    button  This will open the Incoming data    window  Check the different fields in   his window  there needs to be a minimum of the following items in order for Piscatus3    O operate                 UTC Date   UTC Time   Latitude    Longitude    Depth    If some fields are missing like Heading or SOG  go to the    Boat NMEA tab and select  the appropriate NMEA sentence type  Heading may need to be changed from GPHDT  to RMC  Heading  COG and SOG data is not essential but does make the software  better to use     Once you have selected a tide engine  if a tide station is available in your area the above  data will be enough to calculate its current height  Allow up to 30 seconds for the tide  engine to find a station after a lat long position is detected by SMISealog  Additional tide  station options can be chosen on the    Tide Adjustment    tab in the    SMISealog Control  Panel    window     If you have net sensors attached to your trawl this data should appear in the    Incoming  data    window in the right hand column called    Data From Net  Most trawl sensor systems  need to be in a simulation mode in order to output data when the net is not in   the water        Piscatus  Version 5 Installation Guide 23       Note   if
37. t boat GPS position     Note  SMISealog may need to be configured before Piscatus3D can receive GPS position  and other data     see section 4 0        20 Piscatus  Version 5 Installation Guide       4 0 CONFIGURATION OF SMISEALOG    After Piscatus3D has successfully installed you will need to configure it correctly so that  it talks to the boat s electronic equipment  Most of the required configurations are default  settings but they may need a little tweaking depending on the boat involved     4 1 Introduction    SMISealog is the data entry point for the Piscatus3D system  SMISealog listens to the data  being sent into the PCs serial comm port or UDP network  This data is received in NMEA  format from marine equipment  for example  GPS or echo sounder  SMISealog then extracts  the required data from this and shares it to Piscatus3D to be viewed     SMISealog also uses GPS position  date and time data to calculate the current tide  at boat position  This tide value is used by Piscatus3D to correct all recorded depth data  to chart datum     When you first install Piscatus3D there are some settings in SMISealog that will need to be  set  Please read the    Quick setup    section  3 1 2  of the manual for a brief description of this  setup stage  or read the remainder of the manual for a detailed step by step description     4 1 1 Using SMISealog       SMlSealog runs as a background task to Piscatus3D and runs in  EZEREN the Windows system tray  To access the SMISealog menu le
38. ta  Please refer to the    Viewing incoming data    section of this manual    sends lines of data with    taining an identifier and data delimited by commas  There are many different    some of which contain the same data  Piscatus3D must be set up to process  ta your equipment is sending  Piscatus30 knows how to process many different    eans setting the identifier    g on the data type required  An identifier is made up of    er of SD and data type of DBS  therefore the identifier    d NMEA settings can be complicated and should only be    EA setup is much easier  Simply choose between JRC or  scrimination systems  There are  red for this data  We have found that different echo sounders    f seafloor  This offset value  ta sharing between vessels     n to your net positioning    in areal position relative to the  ect what type of net positioning       ave  Selecting one of these will set the correct N  be adjusted for each installation     EA setting below  Settings       26    Piscatus  Version 5 Installation Guide       The default settings in Piscatus3D should be correct to get GPS position and echo sounder  depth from most modern marine electronic equipment  The best way to find what NMEA  strings your equipment outputs in to use the terminal tab in SMISealog  Use this to view a  comm ports data and press the pause button to stop the data display update so you can   read to the individual NMEA strings being received           If you are having problems setting up SMISea
39. this click on the    Terminal    tab and click the    Display SIM data    button   White lines of text should be appearing against the black background            Check processed data  Now check that all data is being processed correctly  To do this  select the    Comms tab and click the    Display Incoming data  The Incoming Data    window  will now be displayed showing you which data is being received and processed        Start Piscatus3D if all the above steps have worked correctly  You will be able to watch  the simulation play        Piscatus  Version 5 Installation Guide 33       4 4 3 Simulation options    There are many specialized options  which can be fine tuned in the simulator     Below is a table of these options which a description on how to use them              Option Description   Line delay This option controls the speed of the simulation  Simulation files  are made up of NMEA lines of data  increasing the delay between  sending each line of data slows the simulation  Default   100 m s   File Repeat By default this is set to play once  This means that the simulation       will play from start to finish only once and then stop  There are two  further options for playing twice and forever        Start or continue  options    These options allow the flow of the simulation file to be changed   There are three options          From start    From line    Continue    From start   starts the simulation from the start every time  he    Start SIM    button is clicked 
40. ving a problem  therefore causing Piscatus3D   to ignore all data  There is a setup mode option at the bottom on the    System    tab in the  SMISealog control panel  Place a tick in this option to make SMISealog ignore GPS position  problems so data can be checked in Piscatus3D  This option is not saved and will be  un ticked when SMISealog is next loaded     4 2 11 Receiving ARPA target data    The settings for receiving ARPA target data are on the    boat NMEA 2   tab in the SMISealog   SMISealog is only able to receive data from the radar NMEA string  RATTM  If this string is  being received that ARPA targets within that string will be listed on this tab  There are no  other settings which need to be adjusted     4 3 Using tide adjustment  4 3 1 How tide adjustments are calculated    Piscatus3D is a utility built into SMISealog that uses data from tide stations around the world  to calculate the tide  Corrections can then be applied to depth data stored in the Piscatus3D  database  The tide station used to calculate the current tide is the closest station within  range of the boat s position  This range is 40 000m  40km  by default  but it can be changed   Once the tide station is found  the GPS date time  or  if unavailable  your computer s date   time  is used to calculate the tide     4 3 2 Viewing current tide adjustment  To view the current tide at the boat s position  open the  SMISealog Control Panel    window     click the    Tide Adjustment    tab and then the   
41. will now be installed    o APIO  First to be installed is what we call the  Predicted Bathymetry  dataset  This is  the satellite altimetry dataset for the  whole planet based on the ETOPO1     A  E    dear na  Dira    dataset  and is what Piscatus3D uses  for its initial maps  Once a boat starts  to add real data  the bathymetry   is immediately updated to use the  real data                    9  Once the Predicted Bathymetry installation has been completed  an empty  BATHYMETRY FDB database file is installed  This database stores the boat s soundings  and hardness roughness data     10  Following installation of the database  Piscatus32 Navigator and high resolution  bathymetry maps are installed              18 Piscatus  Version 5 Installation Guide       11  When installation has completed  a verification program is run to  check everything has been  installed correctly and all services  are running     Iintaaton  crrptete  Pecut sep segunes    oyuer mhont to cormpless tha ina    Retest Lam   Rebost iise      You will be notified when  installation is complete  In order to  finish the installation process and  start all required components and  system reboot is required  Options  are displayed as shown below to  reboot now or later  It is recommended  you reboot now           12  Before your Piscatus3D system will operate the installation will need to be permitted  and SMlSealog will need to be configured to listen to the incoming NMEA data from  the GPS  echo sounder and
42. with the special demo dongle    When you load the disk  go to the Advanced Options   tab and select the Display Demo Install button in the  Install Setup menu    When the dealer install option has been selected the  button to install Piscatus3   should display the text      Install Piscatus   Demo Version    The Dealer Demo version actually installs a database containing  more detailed bathymetric data for display purposes        Piscatus  Version 5 Installation Guide       3 Trial installation A 60 day trial license for the full version of Piscatus3D can be   loaded during the installation process      When you load the disk  simply select the Install Piscatus3D  Version 5 Trial button on the default menu      The trial version does not require a dongle although a  permit code is required for the system to function      Please note that once installed  these 60 day trial licenses  cannot be un installed or re installed       The license will remain on the system for 60 days      After 60 days the installation can continue to be used if a  dongle is inserted into the computer  although you will  need to contact us in sufficient time for us to physically get  a dongle to you      The trial version has full Piscatus3D version 5 functionality   i e  it can receive and save GPS  sounder  etc data           Piscatus   Version 5 Installation Guide 13       Piscatus3D   Functional differences  Demo vs  Full License    FEATURE    Receives instrument inputs       DEMO LICENSE FULL LIC
43. y and Secondary depth data and auto switch    Some vessels have more than one echo sounder  One could be a backup or preferred at  increased depths  The    Sounder Data    section of the    Boat NMEA tab allows SMISealog to be  setup to receive data from two different NMEA strings  SMlSealog will switch from primary  to secondary  or vice versa  automatically when no depth data has been received for some  time or when the auto switch depth is crossed        28 Piscatus  Version 5 Installation Guide       4 2 9 Filtering data    To access the filter settings  open the  SMISealog Control Panel    window  click the    NMEA  Processing    tab and then the    Filtering    tab  The Piscatus  system does data cleaning and  these are the filtering settings here in SMISealog  These settings allow incoming data points  to be compared with recent data points and are designed to filter out erroneous data  points  for example  double echo used as bottom depth by your echo sounder        Filter setting    Description       Vessel position       Sometimes GPS position can jump and cause Piscatus3D to load  another 3D seabed map  By setting this option GPS positions  further than 1000 metres from your last known good position will  be ignored  This is automatically corrected if more than six GPS  positions are found to be beyond 1000 metres                 Min max  acceptable depth    This is a simple check on the data coming in from the echo  sounder  It basically stops huge errors from the
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
DMS Go - GE Measurement & Control    Bomba de calor de aire/agua dividida  HM*-16  こちら - 株式会社エスキュービズム通商  Damian full shop  R0E001000EXT00 Users Manual (External Trigger Cable for E100  TempSpray-H306 TempSpray-H206 TempSpray-H106  NS フリーアドレスタイプ取扱説明書 - Garage    Copyright © All rights reserved. 
   Failed to retrieve file