Home

DNA-5050 - B&H Photo Video Digital Cameras, Photography

image

Contents

1. DNA 5050 Set up and Operations Handbook 714 Seaboard Street 9B Myrtle Beach SC 29577 USA www glidegear net Table of Contents ill a sn se se eee en en eee ioe pee ees A eae ee eee ene ees GLIDE GEAR DNA 5050 Parts and Components 0 0000 c ee eee eee 3 Assembling your GLIDE GEAR DNA 5050 0 2222 5 Attaching your camera to your GLIDE GEAR DNA 5050 0005 8 Balancing your GLIDE GEAR DNA 5050 2 0 22 10 Handling your GLIDE GEAR DNA 5050 2 2222 14 Operating your GLIDE GEAR DNA 5050 2 ee ee 15 Shooting Tips Ae CHA PEPE PAA 16 Improper Handling Techniques a 7 Other Camera Attachment Methods 0 0 0 ccc eee eee 7 Professional USO 4 ana cu nn eh par ER Oe EE he eee oma eee eee ded es 7 Maintaining your GLIDE GEAR DNA 5050 2 es 18 WOMINGS Su u un a nme AKA Be ae pea aed MA ee LA ee ee ee ea re 18 WANNY zu un nahe anna anne ce ana ee Snake Sean bees ee 19 Introduction Congratulations You have in your hands the wonderfully advanced GLIDE GEAR DNA 5050 our most advanced hand held camera stabilizer With the cutting edge design and engineering of the GLIDE GEAR DNA 5050 Camera Stabilizer hard to watch shaky camera footage will be a thing of the past now you can have beautifully smooth professional quality footage The GLIDE GEAR DNA 5050 sports advanced features unique in its category of hand held camera stabilizers As with all GL
2. Attaching Your Camera To Your GLIDE GEAR DNA 5050 28 It s now time to attach your camera to the GLIDE GEAR DNA 5050 s Camera Plate First remove the Camera Plate from the head assembly by turning the Knobs counterclockwise and pulling on them to release 29 Check the bottom of your camera and locate the threaded insert 30 Next lay your camera on a stable surface and place it bottom side up Put the Camera Plate over the camera bottom Threaded Insert and center it as shown in image 31 31 Align the Camera Plate to the bottom of your camera and make sure that it is flush against the surface Line up the threaded insert on the bottom of your camera with one of the mounting holes in the Camera Plate NOTE If you re using a camcorder or film camera that is larger that the one shown in this manual you might want to first find the true front to back center of gravity You can do this by rolling the base of your camera on a pencil until it is balanced on it mark that point on the camera s side with a small piece of tape then refer to this marking to center the Camera Plate over you camera s center of gravity 32 Use a camera mounting screw and a washer to attach the Camera Plate to your camera NOTE Check how the shorter camera mounting screw fits If it does not fasten your camera securely to the Camera Plate then try a slightly longer mounting screw You can also try using more than one washer or elimina
3. and Components gt Welcome to your GLIDE GEAR experience With your purchase of the GLIDE GEAR DNA 5050 comes a whole new perspective on shooting and creativity As you unpack your GLIDE GEAR DNA 5050 you will find the following components From the box e GLIDE GEAR DNA 5050 Manual e Central Post with Gimbal assembly e Camera Plate e Camera Mounting Platform e Telescoping Post e Base Platform e Counterweight Plates e Hardware bag Tools for assembly Standard and Phillips head screwdrivers not included The GLIDE GEAR DNA 5050 has a Central Post with the Gimbal assembly attached IMPORTANT Do not make any adjustments or attempt to tighten the original factory settings on the Gimbal handle and yoke These parts need to be able to move freely and stay loose exactly as they have been shipped to you 2 These make up the head assembly of the GLIDE GEAR DNA 5050 It includes e Camera Plate e Camera Mounting Platform 3 The GLIDE GEAR DNA 5050 s Camera Plate is where the camera is mounted To take it out and release the plate quickly from the head assembly turn the knobs counterclockwise and pull on them to release 4 The Camera Mounting Platform features forward and back ward and sideways movement adjustment knobs 5 The Telescoping Post 6 The Base Platform This can expand to accommodate the Counterweights 7 The GLIDE GEAR DNA 5050 comes with hardware that consists of e
4. stopping If the abrupt movement causes the GLIDE GEAR DNA 5050 s Base Platform to swing or pendulum away from you or from the upright vertical position it was previously in then you have confirmation that it is not verti cally balanced Adjust the number of Counterweight Plates on the Base Platform or lengthen or shorten the Telescoping Post until the GLIDE GEAR DNA 5050 stays vertical during the Movement Test Handling Your GLIDE GEAR DNA 5050 Knowing how to correctly handle your GLIDE GEAR DNA 5050 is a must prior to shooting or filming any project In the operation of the your DNA 5050 one hand will be used to hold the Handle Grip and the other to guide the camera in the direction you want to shoot For clar ity s sake let s call the hand on the Handle Grip the Grip Hand and the hand that directs the camera s movements such as tilting panning etc the Guide Hand 44 There are a couple of things you need to do to properly han dle your GLIDE GEAR DNA 5050 and they are I grip it firmly and 2 take hold of it either in the middle or near the bottom of the Handle Grip The position you pick will depend on the type of shots you need to take For normal shooting it is best to grip the handle in the middle as in image 44 For shots that require pointing the camera up down or sideways best to grip it firmly at the bottom doing so will allow the yoke of the Gimbal to twist and move around without hitting your h
5. the light lubricating oil for your GLIDE GEAR DNA 5050 s yoke and handle bearings Take care to safeguard your camera from the oil by checking and cleaning up any spill over when you re done Storage When storing your GLIDE GEAR DNA 5050 for long periods of time remember to keep it upright and in a dry or low to normal humidity area as much as possible If you cannot be sure of the environment s humidity conditions we then suggest that the unit be stored in an airtight plastic container or bag Storing the unit upright helps in alleviating the stress on the system Warnings Take care when using your GLIDE GEAR DNA 5050 at night in low light conditions and in uneven or unfamiliar terrain A dangerous and bad mistake you can make is focusing so much on what you re shooting and not seeing the hazards along your path You can trip fall over or slip on something or stray into a dangerous area like a street with busy automobile traffic a deep pothole or even a swimming pool Extra care is also necessary when tackling stairs and other kinds of uneven ground These warnings apply to shooting in daylight and well lit areas Minors using this product should have adult supervision If you intend to shoot while moving fast or while traversing Uneven terrain do not hesitate to wear protective gear such as knee and elbow pads a helmet and eye protection Warranty We will repair or replace you GLIDE GEAR DNA 5050 free of charge in the
6. 2 Counterweight Plates e 4 Thumb Nuts 8 Hardware set for the GLIDE GEAR DNA 5050 e 2 Weight Bolts with Washers e 2 Camera Mounting Screws e 4 Metal Washers Assembling Your GLIDE GEAR DNA 5050 10 Start with the Base Platform and the Telescoping Post 1 Check the bottom one end of the Telescoping Post it has the threaded insert 12 A threaded stud attached to the center of the Base Platform is the connection point for the Telescoping Post Screw in the Telescoping Post securely to connect it to the Base Platform 13 The Telescoping Post attached to the Base Platform should look like image 13 IH Locate one pair of bolts and attach their corresponding washers from the hardware pack 15 Insert the bolts with their washers into the slots on the Base Platform Do this for both sides 6 PROGRESS CHECK your GLIDE GEAR DNA 5050 should look like image 16 I7 Get the Counterweight Plates and slide them through the bolts on the Base Platform The holes in the Counterweight Plates line up with the position of the bolts NOTE Heavier cameras will need more counterweight than lighter ones 18 Lock the Counterweight Plates in place with thumb nuts Do the same for the other stack on the other side of the Base Plat form 19 PROGRESS CHECK Your GLIDE GEAR DNA 5050 now has the Base Platform assembled complete with Counterweights NOTE Extending the length of the Base Platform and mov ing the Count
7. A 5050 moves toward correct vertical balance more in the next section 41 Balancing the Vertical Axis Now that your GLIDE GEAR DNA 5050 is horizontally balanced you can turn your attention to setting up and testing the system s vertical axis balance The point of having a proper vertical balance for your camera and GLIDE GEAR DNA 5050 is so that they can stay level during operation given that you are not applying a pan tilt or roll type of hand pressure to the GLIDE GEAR DNA 5050 Most important of all that the DNA 5050 s Central Post remains vertical even when you are walking running or turning during operation In short if your GLIDE GEAR DNA 5050 is vertically balanced your camera will remain level and the Central Post will stay vertical unless intentionally positioned otherwise A vertically unbalanced GLIDE GEAR DNA 5050 will swing about and pendulum when you walk run or turn 42 Once more if the vertical balance is properly set you will be able to move about quickly as well as start or stop moving suddenly and still keep the Central Post vertical To adjust the GLIDE GEAR DNA 5050 s vertical balance you can either attach or take out Counterweights from the Base Platform or telescope the Base Platform in or out When you have more or less the right amount of weight on the Base Platform you can fine tune the vertical balance further by using the Telescoping Post NOTE The GLIDE GEAR DNA 5050 swinging between ho
8. IDE GEAR Camera Stabilizers recording devices mounted on them will shoot smoothly free from bumps shakes and other common disruptive movements Due to the balance and isolation it provides the GLIDE GEAR DNA 5050 will give your devices a seemingly floating movement free from any instability or shaking Now you can perform all sorts of movements with your camera pan tilt boom and move without any worries about maintaining balance and stability The GLIDE GEAR DNA 5050 works so amazingly that you can produce professional quality shots even in extreme conditions such as going over rugged terrain or running up and down steps When it can perform that well under such conditions you can just imagine how magical your output will be when shooting normally in natural walking speed or slow movement around a subject The GLIDE GEAR DNA 5050 features an offset foam wrapped cushioned Handle Grip that is connected to a free floating three axis Gimbal This is what allows the camera operator to move it from side to side or up and down yet keep the camera stable the camera is isolated from all the movement The Hand Grip and Gimbal together attenuate the bouncy jumpy movement that often results from the use of similar systems out in the market This is because our Handle Grip has been engineered to allow for vertical movement This design element combined with the overall higher inertia of the GLIDE GEAR DNA 5050 results in greater stabilization espec
9. UK Do not send the unit to us without first getting a response and acquiring a return authorization number GLIDE GEAR LLC 714 Seaboard Street 9B Myrtle Beach SC 29577 USA www glidegear net
10. amera is securely attached to the Camera Plate and all four knobs are pushed in and tightened b The lens cap has been removed and is secure c The camera battery and video tape disc are installed d The flip out LCD is in its operating position if applicable as seen in image 36 e The Telescoping Clamp is secure f Weights have been added to the Base Platform 37 Balancing the Horizontal Axis At this point your GLIDE GEAR DNA 5050 is properly assembled You can now move on to setting up and testing the horizontal balance of the system You need horizontal balance for your GLIDE GEAR DNA 5050 so it can allow your camera to stay level during operation given that you are not applying a pan tilt or roll type of hand pressure to the GLIDE GEAR DNA 5050 In short if your GLIDE GEAR DNA 5050 is horizontally balanced your camera will remain level and the Central Post will stay verti cal unless intentionally positioned otherwise Additionally if the GLIDE GEAR DNA 5050 is horizontally balanced it will always return to a level and vertical position after you release any pan tilt or roll pressure on the Central Post as seen in image 37 38 Testing for Proper Horizontal Balance When doing the test for proper horizontal balance you have to make sure to pick up your GLIDE GEAR DNA 5050 from a flat and level surface such as a table you also need to let the GLIDE GEAR DNA 5050 hang freely as you hold it from the by the Handle G
11. ands or knuckles 45 As you handle your GLIDE GEAR DNA 5050 you will want to use your Guide Hand to lightly hold onto either the point just under the yoke and bearing assembly as seen in image 45 or a spot down by the Base Platform as seen in image 52 When using your GLIDE GEAR DNA 5050 these two areas allow for the easiest and best control Again the hand position you pick will depend on the type of shots you need to take Observe how the Guide Hand does not touch the yoke or main bearing assembly 46 Normal shooting will require that you hold the GLIDE GEAR DNA 5050 with your Guide Hand at the spot just underneath the yoke as seen in image 45 Handling it this way will allow you to subtly aim your camera while maintaining the camera s upright position This is the position that will let you shoot the smoothest footage when walking or running with the unit during normal shooting NOTE Take note that your Guide Hand and Grip Hand do not touch the bearing as sembly or yoke while shooting doing so can lead to unsteady shooting Irregular or unconventional shots such as those that require pointing the camera straight up or down or sideways will need you to hold the GLIDE GEAR DNA 5050 s lower portion or by the Base Platform as seen in image 52 This will give your Guide Hand a higher measure of control over the unit even while shooting erratic shots and angles Operating Your GLIDE GEAR DNA 5050 47 The GLIDE GEAR DNA 5050
12. by turning the adjustment knob clockwise Always secure the thumb screws after any adjustments If you still cannot get the front to back axis balanced with method then we suggest re mounting your camera to a different hole on the Camera Plate When you attain balance for the front to back axis secure the four thumb screws on the Camera Mounting Platform 39 Should your GLIDE GEAR DNA 5050 lean sideways for example to the right you will need to loosen the thumb screws at the bottom of the Camera Mounting Platform and turn the side to side adjustment knob counterclockwise Should you notice a leftward lean from the operator s vantage point as seen in image 40 then adjust it to the right by turning the side to side adjustment knob clockwise Remember to always tighten the thumb screws after performing any adjustment A properly adjusted side to side horizontal axis is shown in image 39 40 Once you re done adjusting the side to side balance you might have to go back and tweak the front to back balance in order to get a true fine balance of the of the entire system You can either just do a visual check to judge for the correct horizontal balance of your GLIDE GEAR DNA 5050 or employ a lightweight bubble level not included to make sure NOTE The GLIDE GEAR DNA 5050 s horizontal balance tends to be less sensitive as if becomes more bottom heavy conversely the horizontal balance becomes very sensitive as the GLIDE GEAR DN
13. cise designed to help you use your GLIDE GEAR DNA 5050 more accurately All you will need is some masking tape camera or gaffer s tape First create a cross mark on a flat wall this mark will be for framing purposes Next lay down tape in a straight line on the floor leading up to the cross mark this line should be around 10 to 20 feet long Then the exercise will proceed with you walking the line you laid down on the floor and keeping the cross mark on the wall centered on your LCD monitor as in image 53 The objective of this exercise is to train you precision framing during a shoot Improper Handling Techniques 55 Do not clutch the Central Post when shooting with the GLIDE GEAR DNA 5050 as seen in image 55 Doing so voids the principle of the thee axis Gimbal and the isolation it provides Refer to images 45 and 47 for proper handling of your GLIDE GEAR DNA 5050 56 Do not let the Handle Grip to come into contact with the Camera Mounting Platform as seen in image 56 Such contact will limit your range of motion and will lead to shaky jerky and possibly unusable footage Remember to position the Handle Grip as shown in image 44 Other Camera Attachment Methods Create a Gasket In case your camera does not have a true flat and level bottom to allow for full contact with the Camera Plate getting it solidly attached can become an issue Making and adding a paper cloth or rubber gasket to the Camera Plate can eas
14. erweight Plates further apart will create pan inertia this will slow down the rotation of the sled and may also decrease side to side movement while taking moving shots 20 Next comes the insertion of the Telescoping Post along with the attached Base Platform into the Central Post 21 Refer to image 21 to see how the Telescoping Clamp s adjustment knob should be aligned To get to this aligned position just rotate the entire Central Post into the correct position then tighten the adjustment knob Leave about an inch of the Telescoping Post outside the Central Post under the Telescoping Clamp Aligning the Telescoping Clamp s adjustment knob as instructed does not necessarily affect the function or balance of your GLIDE GEAR DNA 5050 but it does make it easier to reach when you need to use it 22 Tighten the adjustment knob on the Telescoping Clamp Tightening of the adjustment knob should only be done by hand WARNING Do not over tighten this knob 23 PROGRESS CHECK Your GLIDE GEAR DNA 5050 should look like the one in image 23 It will have the Base Platform and Telescoping Post assembly properly aligned and connected to the Central Post The number of Counterweight Plates you will need will vary and will be dictated by the weight of the camera you use We will tackle the setting of the correct number of Counterweights required for your specific camera later 24 Check the threaded insert at the top of the Central P
15. event of a defect in materials or craftsmanship obtained during normal use or handling based on the GLIDE GEAR DNA 5050 user s manual for ninety 90 days from date of shipment shipment date appears on your purchase receipt Shipping packing and insurance costs to and from the factory will be your responsibility This limited warranty is available only to the original buyer and proof of purchase in the form of the original receipt is required The warranty does not include by way of example damage cause by products not supplied Us or damage resulting from mishandling in transit accident misuse neglect vandalism modification lack of reasonable care pertaining to units for commercial use including rental to others of the GLIDE GEAR DNA 5050 or service by anyone other than our company We offer no express warranties except as listed above This warranty awards you specific legal rights You may also have other rights that may differ from state to state GLIDE GEAR is not liable for incidental or consequential damages resulting from the use of the unit or occurring due to any breach of this warranty All express and implied warranties including the warranties of merchantability and fitness for a particular purpose are limited to the ninety 90 day warranty period To get service during or beyond the warranty period you may get in touch with us through glidegearhdsIr gmail com or call us at 843 492 5283 US and 020 8816 7576
16. ially in comparison to the competition Meanwhile the patented precision three axis Gimbal features multiple adjustable axis convergence controls which allows for the compound axes to intersect for correct alignment during operation The GLIDE GEAR DNA 5050 is designed with a Camera Plate on its Camera Mounting Platform this no tools required camera mount allows for a fast attachment and removal of the camera It has ergonomic Control Knobs for easy and accurate adjustment of the platform mount s forward and backward and sideways movement These Control Knobs are how the operator adjusts the camera s horizontal balance An assortment of Counterweights is included with every GLIDE GEAR DNA 5050 By modifying the amount of weight on the Base Platform or by adjusting the height of the telescoping Central Post the camera s vertical balance can easily be fine tuned A properly balanced camera on a GLIDE GEAR DNA 5050 practically floats and is ready to get into the thick of the action whenever you are The GLIDE GEAR DNA 5050 showcases features much sought after by camera operators which are exceptional control and maneuverability and ease of use uwith its solid but exceedingly adjustable control weight and balance distribution areas Setting it up controlling it and making adjustments on the system balance can now be done quickly and with precision What allows for the easy adjustment of the system s dynamic balance and its rota
17. ily resolve this Using the Camera Plate as pattern simply cut the material such as a piece of rubber dishwashing glove and make a hole in it to let the Camera Mounting Bolt through and into the base of your camcorders threaded insert Professional Usage Using the GLIDE GEAR DNA 5050 to achieve professional output perhaps in taking shots or footage you d like to incorporate into a movie or some type of commercial project we highly recommend plenty of pre planning and maybe even rehearsing your shots before the actual shoot Having an assistant especially during complicated shots will increase your chances of getting the professional look you re aiming for Good luck and enjoy shooting with your GLIDE GEAR DNA 5050 Maintenance Cleaning Cleaning your GLIDE GEAR DNA 5050 is simple If or when the unit gets dirty just use a water dampened cloth or sponge to gently wipe it clean Do not use solvents or harsh cleaners of any kind Bearing Maintenance Your GLIDE GEAR DNA 5050 s main bearing is connected to the Central Post approximately two inches from the top The main bearing is metal and is partly enclosed by the bearing assembly If after some time this bearing does not quite turn as smoothly as it originally did you can thinly coat it with light lubricating oil Remember you just need to use a very small amount of oil anything more than that will just ooze out of the bearing and onto to your GLIDE GEAR DNA 5050 You can also use
18. is designed for two handed operation as seen in images 45 and 47 Operating it with your Grip Hand alone the camera is likely to drift away from its original position as you shoot Your Guide Hand is essential in controlling the camera s direction 48 In the operation of the GLIDE GEAR DNA 5050 you will not be able to use the viewfinder Putting your eye right next to the viewfinder s eyecup will hamper the stabilization capabilities of the GLIDE GEAR DNA 5050 It is best to use the camera s built in LCD monitor as shown in image 53 Another option is to attach a separate external monitor directly to the Base Platform This monitor mounting hole can be found at both the front and back edges of the Base Platform 49 While we think attaching an external LCD monitor to the Base Platform is a better option because it will encourage you to look down to check on it more often and therefore get more oppor tunities to look at where you re going and make getting around obstacles in your path safer you can opt to attach the external LCD monitor to the accessory shoe on top of your camera 50 Using your Glide Gear DNA 5050 for extended periods of time can cause fatigue in your grip hand Should tiredness set in while you re in the middle of a shoot you can try switching hand roles in the operation of your GLIDE GEAR DNA 5050 swap your Grip Hand with your Guide Hand and vice versa Or you can opt to take a break and rest for a bi
19. ost 25 Screw in the stud located at the bottom of the Camera Mounting Platform to the threaded insert on top of the Central Post The next steps shows how you are going to align the Camera Mounting Platform so that its front end is parallel to the front end of the Base Platform Correct alignment will have your GLIDE GEAR DNA 5050 looking like the one in image 27 26 We have two ways adjust this alignment The first and simplest method is to loosen the adjustment knob on the Telescoping Clamp and rotate the parts until they are aligned as seen in image 27 then just tightening the adjustment knob back Keep the of Telescoping Post visible below the Telescoping Clamp as before 27 Another way of correctly aligning said parts is to use an Allen wrench to loosen the screw on the top part of the Telescoping Clamp as shown in image 26 Do this until you can rotate and correctly align the parts as shown in image 27 remember to retighten the screw NOTE This method is recommended because it leaves the Telescoping Clamp s adjustment knob properly aligned as in image 21 Again while technically it does not affect the function or balance of your GLIDE GEAR DNA 5050 it does make it easier to reach when you need to use It IMPORTANT When using cameras that weigh less than one pound on the GLIDE GEAR DNA 5050 you will need to increase the camera weight through the addition counter balance weight plates under the camera
20. rip as seen in image 37 A GLIDE GEAR DNA 5050 that is properly balanced on its horizontal axis will be level and upright with the Central Post in virtually a perfect vertical position as seen in images 37 and 39 Chances are your GLIDE GEAR DNA 5050 will not look as it does in images 37 and 39 This just means that you have some adjustments to make WARNING Not having enough Counterweight on the Base Platform at this time will cause the entire GLIDE GEAR DNA 5050 to flip completely upside down Should this happen add more Counterweight Plates to the Base Platform until your GLIDE GEAR remains right side up during this test The best method of adjusting the horizontal balance is to move your camera s center of gravity You can do this in one of two ways a you can re bolt the camera to a different area of the Camera Plate or b you can adjust the position of the Camera Plate and the Camera Mounting Platform either front to back or side to side with the camera on it Option b is the preferred method Should your GLIDE GEAR DNA 5050 tilt as it does in image 38 you then need to loosen the thumb screws on the sides of the Camera Mounting Platform and turn the adjustment knob counterclockwise If the GLIDE GEAR DNA 5050 still tilts to the front move the Camera Plate a little more to the back by turning the adjustment knob If the GLIDE GEAR DNA 5050 is tilting to the back instead then move the Camera Plate to the front
21. rizontal and vertical during the Sled Arc Test as seen in image 42 43 The Sled Arc Test is performed to check the balance of the vertical axis Doing the Sled Arc Test is as simple as holding the GLIDE GEAR DNA 5050 by its Handle Grip pulling the Base Platform up and back until the Central Post is horizontal and motionless as in image 41 then gently letting the Base Platform go After that you need to take note how many seconds it will take for the GLIDE GEAR DNA 5050 to go from the horizontal position is was just in as shown in image 42 to the moment it first passes the vertical position A vertically balanced GLIDE GEAR DNA 5050 will take approximately two to three seconds also known as Drop Time to pass the vertical position Make sure to count your seconds by reciting them to beat like one one thousand two one thousand and so on for better accuracy Adjust the number of Counterweight Plates on the Base Platform or lengthen or shorten the Telescoping Post until it takes only two to three seconds for the GLIDE GEAR DNA 5050 to swing in an arc from horizontal to vertical NOTE The length of Drop Time set will in the end be up to you to decide Different Drop Times affect the vertical balance and as a result will change the obtainable shooting output An alternative method to check for proper vertical balance is the Movement Test It requires moving forward with the GLIDE GEAR DNA 5050 and suddenly
22. t by placing the unit upright on a level surface or laying it on the ground if you re using the bracket you can also dock the sled GLIDE GEAR also has separate accessories for the DNA 5050 that can address your need for help in handling the unit for longer periods of time Check out our website www glidegearhdsir com or give us a call to learn more 51 In the handling or operation of your GLIDE GEAR DNA 5050 be aware and steer clear of sudden and forceful movements such as a violent jerking motion with your arm and similar actions Performing such can cause damage to the unit and possibly even get your camera loose from the Camera Plate 52 The GLIDE GEAR DNA 5050 is not made for underwater shooting it does not work underwater The unit is not waterproof You are advised to avoid direct exposure to rain and water spray Also the GLIDE GEAR DNA 5050 s bearings are sensitive to dirt and sand so avoid getting any into them Refer to the bearing maintenance section for more information Shooting Tips amp Tricks 53 When using a standard consumer camcorder you will likely notice that the widest focal length setting on such units are not sufficient to replicate looks often shot with professional cranes dollies and stabilizers but there is a workaround Using a wide angle lens converter over your standard camcorder lens when shooting should take care of this 54 Walking the Line Walking the line is an exer
23. te the use of washers altogether to get the right fit 33 Place your camera on your lap or better yet on a stable but cushioned surface a folded towel on a table is a good example Now that the Camera Plate is in position use a screwdriver to affix the Camera Plate to your camera with the camera mounting screw and the 1 washer pair NOTE Do not over tighten this screw Doing so will likely damage the threaded insert in your camera base 34 PROGRESS CHECK Your camera and Camera Plate should now be securely attached to each other as shown in image 34 NOTE If the Camera Plate can be easily rotated on the base of your camera even when you have adequately tightened the camera mounting screw and you don t feel comfortable tightening the camera mounting screw some more then you should consider using some kind of flex ible gasket between your camera base and the Camera Plate Some materials you can use are rubber tape or a flat piece of rubber you can easily find at home you can for example cut up a piece of old rubber household glove 35 You can now securely place and center your camera with the attached Camera Plate onto the Camera Mounting Platform Check that all knobs are pulled all the way out before installing Once the plate is installed push in the four knobs and turn them clockwise to tighten Balancing Your GLIDE GEAR DNA 5050 36 A checklist before you start the balancing process a The c
24. tional pan inertia is the exclusive dynamic Base Platform that can expand and contract depending on the requirements Whatever the shot and whatever the move this camera stabilizer can bring on that beautifully polished professional output With the GLIDE GEAR DNA 5050 tripods and dollies become non essentials all you will need is to let your imagination and creativity run free GLIDE GEAR continues to develop camera stabilization products for the modern enthusiast and professional continuing to push the envelope in design and manufacturing to ensure that more and more can have access to them This is also why it is fast becoming the choice of this new generation GLIDE GEAR now has a wide array of camera stabilizers every one of which is created to work best with specific camera equipment and shooting requirements To achieve professional quality results with GLIDE GEAR products some practice and a good understanding of the equipment is needed Please read this manual through carefully before setting up and using your GLIDE GEAR DNA 5050 Reading the instructions performing the Setup and Operation steps in the correct order will not only lower the risk of possible accidents that may cause damage to your equipment itll also help you avoid frustration For further technical assistance you may reach us at glidegearhdsir gmail com or call our Technical Support Lines 843 492 5283 US and 020 8816 7576 UK GLIDE GEAR DNA 5050 Parts

Download Pdf Manuals

image

Related Search

Related Contents

RX 4331 1  Bosch GSL 2 Use and Care Manual  Descargar ficha - Pinturas Osel de Celaya  Verbatim PAR16 GU10 7W  VirtualCNC Online Help File - MAL Manufacturing Automation  Gamber-Johnson Interface Plate  Piccolo - asp ag advanced solar products    ICC タブレット教室  020-100300-04_LIT INST SHT Security Kit.fm  

Copyright © All rights reserved.
Failed to retrieve file