Home

Digital Door phone DD-5000

image

Contents

1. Fig 6 3 Dimensions of Name frame NF 1 17 DD 5000 7 Connection of DD 5000 door phone See the door phone module commutation connectors of a door phone on the figure above Description of the mentioned connectors is presented in Table 7 1 selecting of electric installation wire upon the length is presented in Table 7 2 Video d 12v J2 J3 Laaj Laaj Speaker Lightening Table 7 1 Description of call module commutation connectors Marking Description Main connector 12V Power supply contact 12 VDC Power supply ground contact Lock contact Lock contact Doors unlock button commutated with LGND Handset connection line ground Handset connection line positive pole Data bus Video connector 12V Camera power supply contact 12 VDC Camera power supply ground contact Door phone module loudspeaker connector System lightening connector Door phone module microphone connector TM reader connector Table 7 2 Electric installation wire upon the length Wire length Up to 20 meters Up to 100 meters Up to 200 meters Handset connection line wire D 0 5mm S 0 2mm2 2 x Dz0 5mm S 0 4mm2 System power supply wire Electric lock wire Door unlock button wire Use a copper wire for installation 18 tz d eio A standard wiring diagra
2. In order to ensure safety residents often want to refuse using codes that could be learned by friends of residents or the third parties In this case set an access control type allowing to unlock doors externally only using TM RFID identificator For system configuration perform the following 1 disable all types of access conrol 3 SEtt inGS gt gt 3 Acc tYPE gt gt 1 dIS ALL gt gt donE 2 enable access using TM identificators 3 SEttinGS gt gt 3 Acc tYPE gt gt 3 ib gt gt donE 3 enable access using RFID identificators 3 SEttinGS gt gt 3 Acc tYPE gt gt 4 rFid gt gt donE Setting of number of call signals When calling to a flat audio handset a sound signal is sent 5 signals are sent by default Despite signals have been finished to ring a subscriber could receive a call Number of call signals could be changed from 1 to 10 See an example of setting a maximal number of call signals 3 SEtt inGS gt enter gt 4 CS no gt ENTER gt no gt enter call signal no 10 gt ENTER gt donE DD 5000 4 4 Volume control DD 5000 door phone allows to manage audio signal sound volume digitally That means sound levels could be regulated any time easily without any additional tools For Structural scheme of volume control menu see fig 4 4 1 There are three types of setting a signal sound level 1 indoor conversation volume 2 outdo
3. Dii Flas 1 About DD 5000 door phone DD 5000 is a cutting age nowadays door phone of a high protection level and a modern design intended for blocks of flats and could be used in an unfriendly environmental conditions Door phone is created considering the cutting age technical solutions Outdoor station panel system controller commutator and other parts are integrated in one unit of a door phone so less material is used for mounting the system and more time is saved 2 mm stainless steel outdoor station panel of a new design contains a bright and resistant to external influence and kicks of vandals LED display A outdoor station panel of small dimensions width 120 mm height 206 mm could be easy mounted even in narrow areas options inserted panel or mounted above the plaster Keyboard light switches on automatically only in dark period so more electricity is saved A new generation keyboard of a door phone is resistant to kicking Similar keyboards are used in cash points with buttons able to withstand more than a million pressings There is a possibility to reduce system sound signals to the minimum a high level of sound usually annoys residents of the first floor when keeping the same conversation sound Comfortable handsets suit for a modern interior Due to mounted plug switch a call sound could be switched off at nights Entrance doors could be opened using an individual 4 digits door unlock code presented to eac
4. gt gt 1 USEr gt gt Id gt enter ID 56 gt gt _ _ _ _ gt set new code gt gt donE door unlock code for a flat No 56 is entered changed Change Service PIN SPIN code SPIN code allows to enter a system programming mode and is delivered one time when activating this mode SPIN code could be changed using programming menu 2 CodE gt gt 2 SPin gt gt _ _ _ _ gt enter new SPIN code gt gt donE SPIN code is changed Delete user s door unlock codes This operation allows to delete all subscribers door unlock codes it also does not forbid users to create and use in case door unlock code is not forbidden see Entrance control setting Page 25 new codes See User s Manual Page 9 2 CodE gt gt 3 rESEt gt gt rSt gt gt donE codes deleted 4 3 System settings This menu item allows to arrange the main system settings to change unlock delay time lock type access control type and number of calling signals See fig 4 3 1 Fig 4 3 1 Structure of System settings 3 SEttinGS system settings Setting of unlock delay time System applies 5 sec unlock delay time by default Upon a necessity this time could be prolonged or reduced 1 sec 100 sec Pay attention that too long delay time could damage some type of electronic bolt openers See an example of setting 10 sec delay time 3 SEttinGS gt gt 1 Lc dELAY
5. gt gt t gt enter t 10 gt gt donE setting 10 sec delay time Dii Flas Selection of a lock type Door phone DD 5000 allows to manage locks of two types Fig 4 3 2 1 NC locks connected to normally closed circuit i e locks with a permanent power supply paused only when unlocking electromagnetic lock 2 NO locks connected to normally opened circuit i e power supply is used only when unlocking electric bolt 1 nc normal closed electromagnetic lock 2 no normal open electric bolt Fig 4 3 2 Settings of lock type 3 SEttinGS 2 Lc tYPE The first type NC electromagnetic lock is set by default For changing of the setting choose an appropriate lock type 1 NC or 2 NO See an example how to set an outlet of lock management for bolt type lock 3 SEtt inGS gt gt 1 Lc tYPE gt gt 2 no gt gt done Access control settings Access control settings allow to limit ways of external door unlock All access control types are allowed by default fig 4 3 3 i e using TM RFID identificator or entering door unlock code However external door unlock could be forbidden totally upon a necessity Doors could be opened only by an internal unlock button or during conversation with a guest using audio receiver You could set one entrance control type or combine several ones Fig 4 3 3 Entrance control types 3 SEttinGS 3 Acc tYPE
6. It is useful for disabling of several addresses or even all of them at once Enter just the first and the last address as presented by an example 5 USEr gt Enter gt 3 diS int gt ENTER gt S gt enter first address e g ID 36 gt ENTER gt E gt enter last address e g ID 255 gt gt donE ID addresses from 36 to 255 are disabled Enable a group of users ID A group of users ID is connected in the same way Enter the first and the last address as presented by an example 5 USEr gt ENTER gt 4 En int gt gt S gt enter first address e g ID 36 gt gt E gt enter last address e g ID 100 gt gt donE ID addresses from 36 to 255 are enabled Forbid to unlock a door using handset This function limits subscriber s use of an handset allows to talk to a guest but forbids to unlock the door 5 USEr gt ENTER gt b oFF Lc gt ENTER gt id gt enter ID e g ID 16 gt ENTER gt donE ID 16 subscriber s possibility to unlock the door using an handset is limited Allow to unlock a door using audio receivers In order to restore a possibility to unlock the door using an handset choose item No 6 from menu and define ID as follows 5 USEr gt gt 6 on Lc gt gt id gt enter ID e g ID 16 gt gt donE ID 16 subscriber s possibility to unlock the door using an handset is restored DD 5000 4 6 Se
7. gt 3 hotEL gt 2 rESEt gt gt rSt gt donE An old hotel configuration is deleted a new one is started 2 Add logic addresses of the first floor 101 109 6 AddrESS inG gt ENTER gt 3 hotEL gt ENTER gt 1 Add gt ENTER gt S gt enter the first floor the first flat ID 101 gt gt E gt enter the first floor the last flat ID2109 gt gt donE 3 Add logic addresses of the second floor 204 209 6 AddrESSinG gt gt 3 hotEL gt gt 1 Add gt gt S gt enter the second floor the first flat ID2204 gt gt E gt enter the second floor the last flat ID 209 gt gt donE 4 Add logic addresses of the third floor 301 309 6 AddrESS inG gt 3 hotEL gt 1 Add gt gt S gt enter the third floor the first flat ID 301 gt gt E gt enter the third floor the last flat ID 309 gt gt donE 5 Add logic addresses of the forth floor 301 309 6 AddrESSinG gt gt 3 hotEL gt gt 1 Add gt gt S gt enter the forth floor the first flat ID 401 gt gt E gt enter the forth floor the last flat ID 409 gt gt donE The configuration is finished We recommend preparing a table of physical and logic addresses as shown in the table 4 6 1 NOTE Intervals for logic addresses could be chosen freely However despite an order of entering intervals for logic addresses physical addres
8. a door using handsets ee eere o Nu FY RO P ERN Reged 12 Allow to unlock a door using audio receivers essen enne nnne 12 ao Setting of addreSsmig zuo rod GADO SR ua nd Ceu EL Us uq Puta GANA ca adea tus 13 Rebular dddfessrmBas asc esset eue eoo t O etu o O etas psu te iu 13 SITES OAC RES SIT os sd eost etii eee 13 Hotel addresStig iuc e t o Rt ge eda ap db Bear A Ne t Ra ME edd usa PARU GR ANO 13 AST Reset to factory SUI OS necs ater eer Ei RE Per Ue EAS OVER TUO edu OFF EVE a AER 14 2 How ie USE d door phone ud dw e Md eta das ONC linden 15 Calling To adau i ree cote GR o o GAA A UG a doses 15 Uset s programming Inter face aws e Pe trn eror edet RONA OF WY OCH DOD 15 DD 5000 Entering fromeutside aie e ette ede arenden NS a YD GR OO Fn O 15 Internal door unlock nin ear Rp fati Ur prr RR SUE Mf UR EUR DU Ed Ud Fd Fa ADS 16 G Techniedl data steaten bee NR Cd 17 7 Connection of DD 5000 door Doe au ed oai s Sd dyd dd 19 A standard wiring diagrami Je yo Heo Fy dd t YA FY AT AY UEN UO GO 20 Keyboard name frame lightening wiring diagram nn unnvenssersneeeneeenneenseerseeeenseenneenneerneeenneensen 21 Video camera wiring ASLAM snee 21 Door phone connection te the nebWOTK need A FY FA 22 8 Error its identification and troubleshooting essere enne nennen nennen 24 User EET a tete bd da Mia Rs di tun ted TNS totic oma ta uds htm t dat awe aM O 25 inr d pP 26
9. function is unavailable in case factory PIN code is not changed The System will ask to change a factory code first and then programming of identificators becomes available For changing PIN code two persons are necessary one staying outdoors near a call panel other indoors by a handset 1 Enter a flat number press and wait till a person indoors answers 2 Press and hold _ __ A person indoors should press a door unlock button for three times each second 3 Four dashes will be shown on a display Enter PIN code and press ENTER 4 A new key list number will be shown on a display Attach a new identificator to the reader It will be programmed In case of attaching an old key the system peeps two times without re programming New keys should be programmed one by one separately In order to program several keys repeat the procedure several times Should a mistake appear press CANCEL and start the procedure from the beginning Entering from outside There are two ways of unlocking a door externally Using TM identificator Attach TM key to a reader If the key is suitable added to a door phone memory the door unlocks A rank number of your key and a note OPEN appear on a display shortly with a sound signal In case an identificator is related to a flat a sound signal informing on door unlock using an electronic key will be sent to an handset Using RFID identificator Attach RFID identificator to a door
10. identificator related to ID eneen eene nnne LLALL FF FF tnra nena 8 Delete all identificators froni theamemory o cede uero e tod eae Yd inde Ud enr been b eiae n 8 4 2 Actions With Codes aeisi r e GRYS 8 bet change users door unlock code ien pe eed pelea utet sui e iar ege pe RAT Da GYF ON n ahead 9 Change Service PIN SPIN COdG uice den te eb ee aded eter Hammes 9 Delete user s doer unlock Cole Su iot teen tiui eeeh sed DU GN 9 4 3 System SEL EDS eraat atop dea te alites na one dna teli da e er DAD YA LO ses ses 9 Setting of nlock delay time io emer sar eres NS BF DROP Avec deser aber 9 Selection of a lock tyned ite t od t ls e A ee RT IR Ee ER Me T 10 AWCcess Control sein os sio sue ee tuae e eti ies Deo Y Y enlace 10 Setting of number of call signalu edu Y etit et til etes tse O e Ud vb decet LAS 10 AA Volume contra eate itu Mui tb ta neta ds undis dn dat een mb YG 11 Indoor yo mc COMMOL 2 GE a a y A en 11 Ouidoor volutneconnol es nee 11 System signals sound GORDON usce turo ttti eai Sd WNA ar Ad GYG EB AFAN ed abc i aded 11 4 5 User subscriber administrating iei iai Y dw FYNY ei rede FF FOD FWYD A l1 Disable a user according to Das Secr GYR dea Am GEN DU do Gyd dn 12 Enable a user Accord po LD oa ue abd tena pecca NO te AG Cd o Go GN 12 Disable a group of sets ID nternet YW O ENSE OU Y AF Fy 12 Enablea group of users Das ge Aet euis sna e Pau ON A NN Yn 12 Forbid to unlock
11. 0 in the easiest way avoiding insert into a plaster Roof protects an appliance of direct sun rays and other environmental factors Name frame NF 1 Name frame NF 1 allows to write surnames of residents titles of companies to introduce advertisement texts etc NF 1 is made of stainless steel panel double organic glass mount with lightening and paper for printing your information Surname frame matches design and dimensions of DD 5000 so could be mounted together Power supply 12 VDC 1 5 a stabilized power supply for the whole door phone system Electronic lock DD 5000 call module could manage two types of electric locks electric opener and electromagnetic lock managed by a permanent 12V flow A nominal flow for electric lock must not exceed 0 8A Lock type and locking delay time are set by the program Door unlock button Door unlock button used for unlocking the door when leaving the object In this case any standard button with normally opened contacts is used Audio handsets DD 5000 door phone could be connected with DG H1 and DG H2 type receivers installed to all subscribers in order to talk to a guest calling from the outside call module After the conversation one has a possibility to unlock the door pressing a button on a conversation appliance DG H1 contains another extra button used for unlocking of the second entrance door or corridor door Sound of receiver s signal could be switched off by the switch mounted on a c
12. 99 and press otherwise call will be started automatically after 3 sec Should a mistake appear or for canceling your call press cancer Conversation session starts upon subscriber s whom you are calling to answer During the conversation the subscriber could unlock the door using a button on the handset and let the guest in The conversation is canceled upon handset s hang up pressing by the guest or in 2 min from the beginning of the conversation User s programming interface User s programming interface allows users to set change their individual door unlock code or to add new TM RFID identificators Changing of user s PIN code NOTE Each flat is delivered with an appropriate factory PIN code 1234 Change it otherwise doors unlock by code is unavailable For changing PIN code two persons are necessary one staying outdoors near a outdoor panel other indoors by the handset 1 Enter a flat number press and wait till a person indoors answers 2 Press and hold A person indoors should press a door unlock button for three times each second 3 Four dashes will be shown on a display Enter an old or factory PIN and press ENTER 4 Aword PIN flashes and four dashes are shown on a display Enter a new PIN and press ENTER If made a mistake press and start the procedure over If all steps are performed correctly the PIN code will be changed Programming of new identificators NOTE This
13. DD 5000 Digital Door phone DD 5000 iii eit oc Table of Contents Abou DE 000 door pones touc ovid ca d dat exci Rush drcum MD at aedi dolus ue uM Aud Ue Oan d 4 1 1 General features of the DD5000 Digital Door phones arseen en ct ee aes 4 2 Components of the ystam eren mese Se Fe ope S ehe ince Sac ea e vehit eee 5 Keyboard lightening frame DF a AAA DL NN E tetas PU Ha tede UN EM dud CYR Y end 5 Keyboard lightening LET 1i sf e NE EE eae e eene 5 Roof to mount above plaster DR las eges ad Fd DDE CI y GT AUD 5 Tae trame NBE docs dune EEE E E enen 5 PO WET SU PV ane Gn d nme iie npe GOD weet A E CD GC CO NA GY O 5 Electronio lock arara Na RY FF Y Hyn sla FF NG dede 5 Door VIO COUT ese CN Y d GE A nee s eee 5 Audio HATA tS Gn etsen date nA GO A A umma aus Mei Ep E E 5 Video audioadapto ADV FOD uu Au AU A AA en AA GAN 5 Network connection adaptor DD S2 l deese scettr retten DAFN GR UA ASAU gk US 5 SAVIO UIT o CHE S yS Ea a Ad Cd NN Y RD eoa ur e E NES 6 aDD 5U00 propraniman ou eu dw O dd FC er ele 7 Activation of programming mode eicere DC FN ed pei e a ce E I Hl FFR 7 Leaving programming mode iaer CHAF AR ANY a A NT YO 7 4 1 Actions with identi FOLS Nanasan trea benede and onontdekte 7 Adda new TACT TCA LOLS eneen ee en dea ul dta dta et 8 Add Service adentrficatots e oig ba Foi EU IRR UA FIG MUNERA PRORA EU UR MATIN en dw 8 Delete identificator upon its rank number ener nennen eene 8 Delete
14. aren t any of the mentioned features demount door phone module and present it to service workshops Er 3 clean TM reader in bottom part of door phone module Stored dust water ice or snow could disturb system operation In case error mark appears demount door phone module and present it to service workshops Er 4 Er 5 restart the system switch off the door phone power supply and switch it on again In case error mark appears demount module and present it to service workshops 23 DD 5000 User Manual NOTE Each flat is delivered with an appropriate manufacturer PIN code 1234 Change it otherwise doors unlock code and new identificator programming function are unavailable 1 How to use a door phone For connection with a subscriber enter his her flat number from 1 to 9999 and press ENTER otherwise call will be started automatically after 3 sec Should a mistake appear or for canceling your call press CANCEL Conversation starts upon subscriber s whom you are calling to answer During the conversation the subscriber could unlock the doors using a button on audio handset Door unlock delay time is programmed during system installation and does not depend on duration of pressing the unlock button Unlock button functions only within a handset the call was addresses to and only in 2 sec after subscriber s answer Duration of a call and a conversation is limited to 1 min and 2 min accordingly A
15. d correctly the PIN code will be changed 4 Programming of new identificators NOTE This function is unavailable in case factory PIN code is not changed The System will ask to change a factory code first and then programming of identificators becomes available For changing PIN code two persons are necessary one staying outdoors near a call panel other indoors by a handset Enter a flat number press and wait till a person indoors answers Press and hold _ __ A person indoors should press a door unlock button for three times each second Four dashes will be shown on a display Enter PIN code and press ENTER A new key list number will be shown on a display Attach a new identificator to the reader It will be programmed In case of attaching an old key the system peeps two times without re programming mie den New keys should be programmed one by one separately In order to program several keys repeat the procedure several times Should a mistake appear press CANCEL and start the procedure from the beginning 24 Dii Flas Notes 25 DD 5000 26 tz d Alas DIGITALas JSC Kestucio str 62A Vilnius LT08112 Tel 370 5 2336619 info digitalas It www digitalas eu 27
16. e plaster e Audible and visual indication Automatic lightening of a keyboard during a dark period Possibility to connect several systems to a network Protection of Service PIN SPIN code Protection from an electroshock Unlimited amount of Tags related to one User s ID e Comfortable and easy system programming Possibility to program change door lock codes by the User interface Possibility to program TM RFID Tags by the User interface DD 5000T door phone with TM Tag reader DD 5000R door phone with TM and RFID Tag readers Service Tags are used in order to simplify system servicing Page 6 Activation of Programming mode DD 5000 2 Components of the System Call module of a door phone DD 5000 Call module is the main unit of a door phone system with a loudspeaker microphone and a 4 digits LED display also anti vandalism keyboard and electronic Tag readers Possibility to install a video camera DD 5000T call module with TM Tag reader DD 5000R call module with TM and distant RFID Tags reader Keyboard lightening frame LF 1 Keyboard lightening LF 1 intended for door phone call module mounted into a wall inserted option Keyboard lightening LH 1 Keyboard lightening LH 1 intended for door phone call module mounted on the wall with a roof to mount above plaster DR 1 Roof to mount above plaster DR 1 Roof to mount above plaster is needed in order to arrange a door phone DD 500
17. ems are placed in the order that the most frequently used settings could be reached the first e g add delete Tags 6 AddrESS inG setting of addressing 7 F rESEt reset to factory settings Fig 4 1 Menu structural scheme of actions with identificators Activation of programming mode A new door phone outdoor station module does not contain Service PIN SPIN code programmed in advance so during the first programming procedure the System will ask to enter the mentioned code During the first programming procedure enter 1002 A note SET PIN and four horizontal dashes will appear Enter your secret SPIN code of 4 digits NOTE don t lost SPIN code otherwise it will be forbidden to make any programming actions the code could be renewed only at manufacturers or representatives service For programming mode activation enter 1002 and enter SPIN code In case of entering a wrong SPIN code a programming mode will be blocked for 2 minutes Programming mode could be activated using Service Tag For programming mode activation enter 1002 and attach Service Tag to the reader After activation of programming mode browse the MENU by using t ExrER Cancer buttons Button used for approving button for canceling operation or return back for one step Leaving programming mode The System will return to the duty mode automatically after two minutes from the latest action You can leave programming mode b
18. fted by Sh 100 A maximum allowed shifting value is Sh 9744 In this case logic address will be from 9745 to 9999 Hotel addressing Hotel addressing is a type when all 255 physical ID addresses are placed by a rank order from 1 to 255 while logic addresses will be scrolled upon number of floors and number of flats within a floor In order to configure hotel addressing for an appropriate house choose this type of addressing start a new addressing configuration and set intervals for logic addresses See fig 4 6 2 for hotel addressing menu structure 1 Add add new floor interval of logic addresses 3 hotEL 2 rESEt start a new addressing configuration Fig 4 6 2 Hotel addressing menu structure 6 AddrESSinG For better understanding let us analyze an example Let s imagine that we need to configure a door phone for a four storey house with 6 flats on the second floor with numbers starting from No 4 Other floors contain 9 flats See table 4 6 1 for an example with physical FID and logic LID address link Table 4 6 1 An example of hotel addressing Floor number Number of flats within a floor Logic addresses LID Physical addresses FID 101 109 204 209 301 309 401 409 12 Dii eia For configuration a hotel addressing to the mentioned house perform the following steps 1 Choose this type of addressing and start a new addressing configuration 6 AddrESSinG
19. fter this term finishes the system returns to duty mode In case a door was unlocked with your PIN code a handset will shortly peep 3 times Handset s switch on off button allow to switch the receiver off 9 9 2 Door unlock with PIN code NOTE This function is unavailable in case manufacturer PIN code is not changed A subscriber could unlock a door externally with a door unlock code 1 Enter your flat number 2 Press within 3 sec after entering the mentioned number Four dashes will be shown on a display 3 Enter an individual 4 digits PIN code Should a mistake appear press CANCEL and start the procedure from the beginning If all steps are performed correctly the door unlocks 3 Changing of user s PIN code NOTE Each flat is delivered with an appropriate factory PIN code 1234 Change it otherwise doors unlock by code is unavailable For changing PIN code two persons are necessary one staying outdoors near a outdoor panel other indoors by the handset 1 Enter a flat number press and wait till a person indoors answers 2 Press and hold A person indoors should press a door unlock button for three times each second 3 Four dashes will be shown on a display Enter an old or factory PIN and press ENTER 4 Aword PIN flashes and four dashes are shown on a display Enter a new PIN and press ENTER If made a mistake press and start the procedure over If all steps are performe
20. h flat Residents could independently program or change door unlock codes and extra Tags an operation lasts only 2 3 minutes Door phone could be installed with a video camera inside in order to see who is calling out of door That makes your life safer 1 1 General features of the DD5000 Digital Door phone Possibility to connect up to 255 users e Duplex audio connection Two Wire connection line TM Tags reader e RFID Tags reader e Internal memory of 895 Tags e Individual door unlock code Possibility to turn off door unlock codes Possibility to add two Service Tags The doors could be opened by entering the door unlock code using TM or RFID Tags by pressing door unlock button or during conversation with a guest by pressing unlock button on the handset Operating temperature 40 C to 85 C e Small dimensions 120x260x30 mm All system is supplied by a sole power supply 12V Low energy consumption Duty mode with keyboard light 12VDC 85 mA electric flow of electric lock _ Error indication Digital volume control of loudspeaker microphone and the system sound separately Possibility to disable separate users or disable door unlock function Three types of addressing regular shifted and hotel Abright 4 digits LED display e Keyboards with buttons able to withstand more than a million pressings Possibility to install a video camera e Options inserted panel or mounted above th
21. m A minimal standard DD 5000 door phone completion involves Door phone module DD 5000 Stabilized power supply 12V 1 5 A Electronic lock Door unlock button e Door phone handsets AL o E Speaker AU eo Blew TIT Handsets Handsets connection line Stabilized power supply 12VDC 1 5A Electronic Lock electromagnetic lock bolt Door unlock button Fig 7 1 General door phone wiring diagram 19 DD 5000 Keyboard name frame lightening wiring diagram Keyboard lightening frame is attached to J3 lightening connector If name frame is complemented with a door phone frame lightening switches together with keyboard Name frame Keyboard lightening lightening 12 V frame 12 V Video 6 Speaker Lightening p Fig 7 2 System lightening wiring diagram Video camera wiring diagram There is a possibility to mount a video camera to a door phone module See fig 7 3 for video camera wiring diagram Pay attention a contact log Video is not connected to a door phone circuit as it is intended for commutation GND ground contact 12V video camera power supply contact 12 V voltage appears when calling and during conversation session In order to ensure quality of image use a coaxial wire for transfer of video signal Speaker Lighteni
22. nd gt gt 06 gt change volume by using C buttons gt exter gt donE 4 5 User subscriber administrating Often door phone possibilities allow connect more subscribers than an actual amount In order to avoid any unconnected addresses it could be connected by programming Subscriber administrating function could be used as a preventive measure for subscribers failed to pay for services provided Such subscribers could be disconnected from the system also door unlock function could be limited leaving possibility of conversation See fig 4 5 1 for structural scheme subscriber administrating menu item 10 iz FL as Fig 4 5 1 Subscriber administrating menu Disable a user according to ID When disabling a user from the system according to ID the possibility to use handset and individual door unlock code are totally limited However a possibility to use TM RFID identificators remains 5 USEr gt ENTER gt 1 diS onE gt ENTER gt id gt enter ID e g ID 12 gt ENTER gt donE ID 12 disabled Enable a user according to ID To enable user according ID is as easy as to disable After enabling a user all previous settings related to user s ID remain e g Door unlock code 5 USEr gt gt 2 En onE gt gt id gt enter ID e g ID 12 gt gt donE ID 12 enabled Disable a group of users ID This function allows to disable a whole interval of ID addresses
23. ng Video signal Ss gem coaxial wire Fig 7 3 Video camera wiring diagram 20 tz d eio Door phone connection to the network A network connection is needed in case a room residential house or office has several entrances In this case a door phone module DD 5000 is mounted for each entrance with a general connection to one commutator See fig 7 4 for wiring diagram for two DD 5000 call modules See fig 7 5 for wiring diagram for five DD 5000 call modules Pow er Supply No 3 12V 1 5A Electromagnetic lock el bolt Electromagnetic Lock DD 5000 2 Pow er Supply No 2 12V 0 5A Door Unlock 20 B EE Handsets connection line Handsets Pow er Supply No 1 12V 1 5A Electromagnetic Lock Electromagnetic lock el bolt OO OE REEN EEEE E Door Unlock Fig 7 4 Wiring diagram for two DD 5000 call modules 21 DD 5000 DD S2 1 2 Pow er Supply No 2 12V 0 5A Handset Pow er Supply oS No 1 12V 0 5A DD 5000 2 DD 5000 3 DD 5000 4 DD 5000 5 Handsets connection line Fig 7 5 Wiring diagram for five DD 5000 call modules NOTE All system units door phone modules and commutators should be supplied from the separate power supply In network system audio handse
24. nly Internal door unlock To unlock the door from inside the building press an unlock button placed indoors near the door DD 5000T door phone with TM reader DD 5000R door phone with TM and RFID readers Ways of entering identificators to a door phone memory are described in the clause Enter a new identificator page 7 or User s Manual page 24 A possibility to unlock the door using a handset could be limited by programming See Forbid door unlock using an audio receiver upon ID Page 7 15 DD 5000 6 Technical data Possibility to connect up to 255 users Two Wire connection line Duplex audio connection e TM RFID readers nternal memory of 895 Tags Individual door unlock code Operating temperature 40 C to 85 C e Small dimensions 120x260x30 mm e All system is supplied by a sole power supply 12V Low energy consumption Duty mode with keyboard light 12VDC 85 mA electric flow of electric lock A bright 4 digits LED display Three types of addressing regular shifted and hotel Possibility to install a video camera DD 5000T door phone with TM reader DD 5000R door phone with TM and RFID readers o Ji OOH OEE HEGE tE s 2 o o Fig 6 1 Dimensions of DD 5000 door phone 16 gt d zd d 2 fm d BS s 33 Fig 6 2 Dimensions of roof to mount above plaster DR 1 261 251
25. of such type could be entered to door phone memory Service identificator could be used for door unlock egually to traditional Keys However this Key activates programming mode without SPIN code For recording Service identificator to memory choose 1 tAG gt 1 S Add from menu and attach a new key to reader 1 tAG gt Enter gt 2 S Add gt ENTER gt S x gt add new keys one by one S x shows recorded identificator s rank number in door phone memory S means that this key is Service identificator Delete identificator upon its rank number Identificator s rank number is set in door phone memory automatically after adding new one This number is shown on a display each time when door is unlocked using an appropriate identificator This number helps to delete a wished key lost defected from door phone memory See an example of deleting identificator with a rank number n 23 1 tAG gt 3 no dEL gt no gt enter no 23 gt gt donE identificator deleted Delete identificator related to ID One ID could be related to several identificators This function helps to delete it together at once See an example of deleting identificators related to ID 34 1 tAG gt gt 4 Id dEL gt gt Id gt enter ID 34 gt gt donE all identificators related to a subscriber from a flat No 34 ID 34 Delete all identificators from the memory For deleting all iden
26. onversation appliance Video audio adaptor ADV 100 ADV 100 allows to connect analogous video audio devices Network connection adaptor DD S2 1 In order to connect two or more call modules to a network DD S2 1 adaptor could be used Three call modules could be connected using one adaptor In order to connect more modules with one adaptor cascade DD 2 1 DIT FL as 3 Mounting the System NO a F WN gt Read User s manual and description of door phone DD 5000 Choose the necessary system completion Components of the System Set mounting places of call module and other parts Choose System connection scheme DD 5000 Connection Design wire installation scheme and choose wires accordingly DD 5000 Connection Set System audio receiver physic and logic addresses 4 6 Setting of addresses Install the System Switch the System power supply and begin programming works Set the main System settings lock type and delay time 4 3 System settings Choose addressing type 4 6 Setting of addresses Set Subscribers administration rules 4 6 Subscribers administrating Perform other necessary works for system programming 4 DD 5000 programming Check audio connection with subscribers and regulate the sound if necessary 4 4 Setting the sound Check operation of the whole system DD 5000 4 DD 5000 programming Programming mode consists of 7 main MENU items For programming mode menu structure see fig 4 1 Menu it
27. or conversation volume 3 volume of system sound buttons beep sound door unlock sound etc 1 Indoor indoor volume control 2 outdoor outdoor volume control 3 Sound system sound volume control Fig 4 4 1 Structural scheme of volume control menu 4 voL volume control Indoor volume control Indoor volume is set for 6 under 1 10 point scale by default For change of set value choose this menu item and perform actions following an example 4 voL gt gt 1 Indoor gt gt 06 gt change volume by using C buttons gt gt donE Outdoor volume control This menu item allows to change outdoor volume It is set for 6 under 1 10 point scale by default Loudspeaker volume is changed performing actions similar to indoor volume 4 voL gt gt 2 outdoor gt gt 06 gt change volume by using t _ _ __ buttons gt gt donE System signals sound control DD 5000 door phone allows to regulate system signal sound volume System signals means all other system audible signals sounds of keyboard button pressing door unlock signal system informational signals and others except volume of conversation This function is necessary in case residents of the first floor are annoyed by too loud peeping of door phone system You could lower a door phone sound as preferred without changing conversational volume Loudness is changed as follows 4 voL gt gt 3 Sou
28. phone display reader antenna is mounted within If the identificator is suitable added to a door phone memory the door unlocks A rank number of the identificator and a note OPEN appear on a display shortly with a sound signal In case an identificator is related to a flat a sound signal informing on door unlock using an electronic key will be sent to an handset Entering a door unlock code A door unlock code consists from a flat number ID a keyboard symbo and an individual 4 digits code XXXX ID XXXX For 4 digits code programming see Enter change a door unlock code page 25 or eem 14 tz d Alas User s Manual page 24 After entering a right code using a keyboard the door unlocks A note OPEN appears on a display with a sound signal of the door phone and an additional sound signal informing on door unlock using individual code related to the flat will be sent to an audio receiver Doors could be unlocked by the person you are calling to during the conversation In order to come indoors a person a guest could call to any flat During the conversation other person by the handset has a possibility to unlock the door and let the guest in to unlock the door is possible after 2 sec from the beginning of the conversation For unlock the door press a button within the handset without hang up Door could be unlocked using the handset a call is addressed to during the conversational session o
29. ses are placed by its rank order from 1 to 255 the total sum of flats connected to a door phone must not exceed 255 4 7 Reset to factory settings To reset system to factory settings choose an appropriate menu item and confirm your chose See an example of reset to factory settings 7 F rESEt gt gt rSt gt gt donE After this step the system restarts automatically and factory settings come into effect NOTE Restoring of factory settings is valid for only ones defined in table 4 7 1 In order to reset factory state of the whole system delete all identificators separately See Delete all identificators in memory page 7 also delete all users codes See Delete users door unlock codes page 8 Table 4 7 1 Values of factory settings Description Factory value 3 SEttinGS 1 Lc dELAY Unlock delay time 1 100 sec 5 sec 2 Lc tYPE Lock type electromagnetic lock electric bolt NC electromagnetic lock 3 Acc tYPE Access control type code TM key RFID identificator 4 CS no Number of call signals 4 voL 1 Indoor Indoor volume level 1 10 2 outdoor Outdoor volume level 1 10 3 Sound System signals sound level 1 10 6 AddrESSinG Type of addressing regular shifted hotel regular 13 DD 5000 5 How to use a door phone Calling to a flat For connection with a subscriber enter his her flat s number from 1 to 99
30. tificators including Service identificators from the memory perform the operation defined below 1 tAG gt gt 5 ALL dEL gt gt dEL gt gt donE all identificators are deleted 4 2 Actions with codes Door phone DD 5000 does not contain door unlock codes generated and entered to memory in advance Each user has a possibility to create and change his door unlock code using user s programming link See User s Manual Page 25 No one including system installing personnel does not Know a code in advance which helps to increase a level of system safety However upon a necessity system adjuster or administrator has a possibility to deliver change or delete System user s or Service codes See fig 4 2 1 for Actions with codes menu item structure DD 5000 1 USEr set change users door unlock code 2 SPin change Service PIN SPIN code 3 rESEt delete user s door unlock codes Fig 4 2 1 Structural scheme of code programming menu 2 CodE action with codes Set change users door unlock code System administrator can enter a new or change an old user s door unlock code Administrator s rights allow to change the mentioned code even without a previous one Delivery of a new code and change or an old one are performed according to similar procedure enter an appropriate subscriber s ID and enter a new code See an example of changing door unlock code for a flat No 56 2 CodE
31. ts connected to commutator outlet A maximum number of subscribers audio handsets within network system is up to 255 One audio connection with a subscriber from a door phone module is allowed In case calling from other door phone modules system indicates to be busy 22 Dii cha 8 Error its identification and troubleshooting Door phone DD 5000 graphically indicates the main errors Graphical codes and descriptions of errors fixed by a door phone are presented in table 6 1 In case of Er2 Er5 errors doors have been unlocked every 5 minutes automatically In case of Er 1 error calls to audio handsets fail but doors could be unlocked by door unlock code or using electronic identificators Table 6 1 Error indication and description Error code Possible reason Short circuit of handsets connection line Breakdown of a keyboard seized button or damaged keyboard Short circuit of TM key reader Error breakdown of system internal data link Troubleshooting Er 1 switch off a door phone power supply disconnect handsets connection line wires and switch power supply on In case a door phone does not show error Er 1 check receiver line on the matter of short circuit or breakdown In case error mark appears demount door phone module and present it to service workshops e Er 2 inspect the keyboard carefully on the matter of physical deformation or damages check whether no button is seized In case there
32. tting of addressing DD 5000 door phone system allows to use three types of addressing fig 4 6 1 regular shifted and hotel The mentioned types are described in detail below 1 rEGULAr regular addressing 2 ShiFtEd shifted addressing 6 AddrESSinG setting of addressing 3 hotEL hotel addressing Fig 4 6 1 Setting of addressing Regular addressing Set in the system by default This is a regular type of addressing all 255 physical and logic ID addresses are placed by a rank order from 1 to 255 In order to activate this type perform the following 6 AddrESSinG gt gt 1 rEGULAr gt gt donE regular addressing is set Shifted addressing Shifted addressing is a type when all 255 physical ID addresses are placed by a rank order from 1 to 255 while logic addresses will be shifted upon an appropriate constant value For example if addressing is set for Sh 100 logic addresses will be placed from 101 to 355 In this case when calling to logic address LID 115 a system will call a physical address FID 15 Sh shifting constant value LID logic address FID physical address Physical address could be counted upon the following formula FID LID Sh e g FID LID Sh 115 100 15 Setting of this type addressing is as follows 6 AddrESSinG gt gt 2 ShiFtEd gt gt Sh gt enter shifting constant e g Sh 100 gt gt donE addressing shi
33. y pressing Cancel 4 1 Actions with identificators Choose this item and perform all actions related to identificators TM and RFID easily to record or delete it See the structural scheme of actions with identificators fig 4 1 1 2 S Add add Servise identificator Fig 4 1 1 Menu structural scheme of actions with identificators 1 tAG actions with identificators Dii cha Add a new identificators There are two ways of adding a new key to door phone memory 1 to record an indentificator without relation to any user 2 to add a key related to a user upon ID number flat number Generally when entering an identificator to memory choose from menu 1 tAG gt 1 Add and enter ID number related to the key One ID number could be related to 895 keys capacity of memory In case you don t want to relate an identificator with a subscriber simply do not enter any ID or enter ID 0 See an example of adding new identificators related to flat No 15 ID 15 1 tAG gt Enter gt 1 Add gt ENTER gt Id gt enter ID215 gt ENTER gt n x gt add new Tags one by one n x shows saved identificator s rank number in door phone memory It will serve in case you need to delete unnecessary or missed identificators from the memory Add Service identificators Service identificator is an auxiliary measure assisting to provide door phone maintenance Two keys