Home

Instructions Manual

image

Contents

1. Instructions Manual INDEX RECOMMENDATIONS AND SUGGESTIONS me CHARACTERISTICS l aaa dau INSTALLATION D USE 12 MAINTENANCE Re fata tah nn adel A A nn tte 14 RECOMMENDATIONS AND SUGGESTIONS ZN The Instructions for Use apply to several versions of this appliance Accordingly you may find descriptions of individual features that do not apply to your specific appliance INSTALLATION The manufacturer will not be held liable for any damages resulting from incorrect or improper installation The minimum safety distance between the cooker top and the extractor hood is 650 mm some models can be installed at a lower height please refer to the paragraphs on working dimensions and installation Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood For Class appliances check that the domestic power supply guarantees adequate earthing Connect the extractor to the exhaust flue through a pipe of minimum diameter 120 mm The route of the flue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc Ifthe extractor is used in conjunction with non electrical appliances e g gas buming appliances a sufficient degree of aeration must be guaranteed in the room in order to prevent the backflow of exhaust gas The kitchen must have an opening communicating directly with the open
2. Hood Down On Off Hood Up Press once The Hood lowers Press a second time The Hood Stops When the movement has been completed the motor turns on at Speed two Off Off The electronic control system recognises and signals two types of fault Led T1 Slow flashing Rapid flashing Current absorption threshold exceeded If an overload condition occurs the fault is signalled by LED T1 on the keyboard flashing once every 2 seconds Check that nothing is blocking normal hood movements The signal remains active until a new hood open close command is given Hood opening safety microswitch tripped If the safety microswitch trips the fault is signalled by LED T1 on the keyboard flashing quickly once every 250 ms This means that the hood has passed the microswitch Call Technical Assistance You can continue to use the hood s light and motor functions while this fault is active Whenever the motor is on LED T1 will continue to flash indicating that the fault is still present The appliance can be controlled using a remote control powered by a 1 5 V carbon zinc alkaline batteries of the standard LRO3 AAA type not included Do not place the remote control near to heat sources e Used batteries must be disposed of in the proper REMOTE CONTROL manner Control panel Button Function Display Q Turns the Motor On Off Hood Closed Press the but
3. air in order to guarantee the entry of clean air When the cooker hood is used in conjunction with appliances supplied with energy other than electric the negative pressure in the room must not exceed 0 04 mbar to prevent fumes being drawn back into the room by the cooker hood In the event of damage to the power cable it must be replaced by the manufacturer or by the technical service department in order to prevent any risks Ifthe instructions for installation for the gas hob specify a greater distance specified above this has to be taken into account Regulations conceming the discharge of air have to be fulfilled USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells lever use the hood for purposes other than for which it has been designed Vee Never leave high naked flames under the hood when itis in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Donotflamb under the range hood risk of fire This appliance is not intended for use by persons including children with reduced physical sen sory or mental capabilities or lack of experience and knowledge unless they have been given su pervision or instruction conceming use of the appliance by a person responsible for their safety Children should be
4. hold for 2 sec for the 24H Function Can only be activated if the Intensive or Delay function is not active Activates and deactivates the 24H function for 10 minutes every hour for 24 hours After this time it is deactivated The led on the motor button on the hood controls will flash once every 2 seconds Turns the Hood lights On Off MAINTENANCE Grease filter The filter must be cleaned every 2 months of operation or more frequently for particularly heavy usage and can be washed in a dishwasher CLEANING METAL SELF SUPPORTING GREASE FILTER Open the lighting unit by pulling on the nocth e Remove the filter one by one pushing it towards the back side of the hood unit and simultaneously pulling downwards Any kind of bending of the filter has to be avoided when wash ing it Before fitting it again into the hood make sure that it is completely dry e When fitting the filter into the hood pay attention that they are mounted in correct position the handle facing outwards e Replace the lighting unit Activated Charcoal Filter Recirculation Version This cannot be washed or regenerated and must be changed ap proximately once every 4 months or more frequently in the case of particularly intensive use CHANGING Open the light unit e Remove grease filter Remove the saturated Activated Charcoal Filters as indicated A Fit the new Filters as indicated B Fit
5. e slot in the threaded pawl This is possible because the cable locking screw involves a system that allows the Cable to slide in one direction only preventing it from sliding in the other direction Make sure that the cables are all the same length to facilitate final levelling operations and that the front left cable is not slacker than the others FIXING THE POWER SUPPLY CABLE Tighten the power supply cable and fix it to the bracket on the ceiling mounted plate using the tongue already mounted and 2 screws Slot the rubber cable raceway already threaded onto the power cable into the slot to prevent future damage e Connect the Hood to the Mains Power Supply inserting a bipolar switch with a contact aperture of at least 3 mm Remove the Grease filters see paragraph Maintenance and make sure that the Power cable connector has been properly inserted into the Suction fan socket At this point it is possible to remove the tie fixing the power supply cable to the hood canopy FITTING THE PLATE COVER AIR OUTLET RECIRCULATION VERSION Open the lighting unit by pulling on the notch provided e Remove the grease filter e Make sure that the Activated charcoal odour filter has been fitted z py USE Control panel Press for 2 seconds to raise the Hood Press briefly to turn the Motor On Off O L Ti Button Function Display L Turns the lights On Off T1
6. of the Hood bearing down on the structure The system used to fix the 4 Cables comprises 3 components Threaded pawl a already mounted on the ceiling Plate e Cable locking screw b provided Safety knob c provided e Pass the 4 cables connected to the hood canopy through the respective holes in the plate cover after opening it as above making sure that it faces in the same direction as the plate connected to the ceiling Insert the hood power supply cable into the hole provided in the cover Warning Do not break or remove the tie that fixes the power supply cable to the hood e Pay attention to the direction of the plate fixed to the ceiling the plate limit pawl has a corresponding hole on the plate cover and on the hood canopy Insert the safety knobs c into the respective cables with the thread to the top Insert the cable locking screws b into the respective cables Pass the Cables into the slots on the threaded pawls a and tighten the cable locking screws b into the pawls themselves e When the operation has been completed the result should be as shown in the figure for all 4 cables a X At this point all 4 cables are now connected to the Plate Tension the Cables by pushing them upwards so that they slide inside the cable locking screw and out through th
7. rnal recirculation ale Sequence of operations Installation Preparing for installation Drilling the Ceiling Shelf and Fixing the support plate Connections Fitting the hood body Functional Check Disposal of Packaging Opening Plate and preparing for assembly e Unfasten the screws joining the plate to its cover Take the plate and position it in the correct direction as shown in the figure Ceiling Shelf drilling and Plate Fixing CEILING SHELF DRILLING Use a plumb line and mark the centre of the cooking hob on the Support Ceiling Shelf Rest the Plate against the Ceiling Shelf making sure it is the right way up as shown in the figure Mark the centres of the holes in the plate Drill the following points Ceilings in solid concrete As per concrete plugs used Ceilings in hollow bricks with 20 mm resistance thickness Drill a hole 10 mm insert Plugs 11 supplied immediately Ceilings with Wood Beams As per Wood Screws used not supplied Wooden shelf with a resistant thickness of 15 mm drill a hole 7 mm Feeding the electric supply cable drill a hole 10 mm Insert two screws crossing them and leaving 4 5 mm from the ceiling for solid concrete concrete plugs not provided for hollow bricks with approx 20 mm resistance thickness screws 12h provided for wooden beams wood screws not provided for wooden shelves screws with wa
8. shers and nuts not provided FIXING THE PLATE Lift up the Fixing plate and fit the slots onto the two screws previously inserted in the ceiling and turn un til they are at the centre of the adjustment slot Warning The plate must be facing in the direction shown in the figure Tighten the two screws completely and screw in the other two provided before locking the screws completely it is possible to make adjustments by turning the piece making sure that the screws do not come out of the adjustment slot The unit must be securely fastened both due to the weight of the Hood and the stress caused by occasional sideways pressure on the Appliance when in position Once the unit has been fixed make sure that the plate is stable In all cases where the Ceiling is not sufficiently strong at the point of suspension the Installation technician must strengthen it with suitable plates and counterplates anchored to structurally sound elements Check that the plate is level on the ceiling CONNECTING HOOD PLATE CABLES N B Before proceeding with installation the Hood must be raised to a height of at least 650 mm above the cooker hob by means of a support or with the assistance of another person Take care not to exceed the maximum hood extension indicated in the dimensional drawing This operation is essential as the Hood Cables are to be connected to the Plate mounted on the ceiling and this must be done without the weight
9. supervised to ensure that they do not play with the appliance CAUTION Accessible parts may become hot when used with cooking appliances MAINTENANCE Switch off or unplug the appliance from the mains supply before carrying out any maintenance work Clean and or replace the Filters after the specified time period Fire hazard Clean the hood using a damp cloth and a neutral liquid detergent s t vane S s Instead it shall be handed over b the applicable colledion point forthe recying of electical and electronic equipment By ensuring this productis disposed of coreaty you wil hep prevent potential negative consequences forthe environment and human health which ooud otherwise be caused by inappropriate waste handing ofthis product Fr more deta information aboutrecyding ofthis product please contact your local ly ofice your household waste disposal service or the shop where you purchased the product CHARACTERISTICS Dimensions Components Ref Q ty Product Components 1 1 Hood Canopy complete with Controls Light Filters Motor 2 1 Hood support plate Ref Q ty Installation Components 11 4 Wall plugs 10 12h 4 Screws 4 2 x 44 4 Q ty Documentation 1 Instruction Manual MAX 1300 INSTALLATION This hood is designed to be mounted on the ceiling on a shelf above a free standing Hob min 650 mm in I Recirculation version Inte
10. the anti grease filter and the Light Unit back into position Lighting unit Warning This appliance is fitted with a white LED lamp classed as 1M according to EN 60825 1 1994 A1 2002 A2 2001 standards maxi mum optical power emitted 439nm 7uW Do not look directly at the light through optical devices binoculars magnifying glasses For replacement contact technical support To purchase contact tech nical support Additional information for the installation technician Hood canopy lighting It is possible to adjust the colour and intensity of the hood canopy lighting Open the lighting unit by pulling on the notch provided e Adjust the lighting using the buttons on button pad B following the indications provided on the label C Procedure to be used in case of malfunction on the movement e Check that the fuse is properly inserted and that it has not burned out for replacing the fuse open the lighting unit and unscrew the fuser holder and replace it with one having the same characteristics Rif A e Check that the hood canopy is fitted level e Check that the four cables are all at the same tension If even these operations do not solve the problem contact the Technical Assistance 436006055 ver3_en
11. ton briefly to start lowering the hood It will stop when the button is pressed again When the movement has been completed the motor will start at speed 2 Hood Open Press and hold for 2 seconds to activate raising of the hood which stops when it reaches the stop Press briefly to stop the movement before the stop is reached Press again briefly to turn the motor on off Press and hold for 2 seconds to start raising of the hood Ifthe motor is on it will first stop the motor and then start the movement Decreases the speed of the Motor Increases the speed of the Motor o INTENSIVE This can only be activated with the hood lowered and when the delay or 24h functions are not active Activates Intensive speed from any other speed To disable it simply press the same button again or turn the motor off Intensive speed is timed to run for 10 minutes At the end of the 10 minutes the system will automati cally return to the speed that was set before The led on the motor button on the hood controls will flash once a second Press briefly for the Delay Function Can only be activated if the Intensive or 24h function is not active Activates and deactivates total shutdown of the hood motorHights after 30 minutes To disable the Delay simply press the button again or turn the motor off The led on the motor button on the hood controls will flash once every 0 5 sec onds Press and

Download Pdf Manuals

image

Related Search

Related Contents

  icecat gas/pro220 ice resurfacer user and maintenance manual from  Mitel 8660 Telephone User Manual  Bellagio - ThisOldTractor  Logitech G600  PR-9D12 - RTR Energía  

Copyright © All rights reserved.
Failed to retrieve file