EXTECH SD800 Manual

image

Contents

1. observing polarity Replace and secure the cover EU users are legally bound by the Battery Ordinance to return used batteries to community collection points or wherever batteries accumulators are sold Disposal in household trash or refuse is prohibited Disposal Follow the valid legal stipulations with respect to the disposal of the device at the end of its lifecycle Battery Safety Reminders Please dispose of batteries responsibly always observe local state and federal regulations with regard to battery disposal Never dispose of batteries in a fire Batteries may explode or leak Never mix battery types Always install new batteries of the 6 SD800 EU EN V2 6 07 13 Specifications Display Measurement sensors CO Response Time Memory Card Datalogger Sampling Time Temperature Compensation Display update rate Data Output Operating Temperature Operating Humidity 60 x 50 mm 2 4 x 2 0 LCD Temperature Internal sensor Relative Humidity Precision capacitance type CO NDIR lt 2 min to 63 of final reading typical SD memory card 1 GB to 16 GB 5 10 30 60 120 300 600 seconds or Auto Automatic Approx 1 second RS 232 0 to 50 C 32 to 122 F Less than 90 RH Power Supply 9V AC adaptor Six 6 AAA UM4 1 5 V batteries for clock backup Weight Meter 240 g 0 53lbs Probe 158g 0 35lb Dimension Meter 132 x 80 x 32mm 5 2 x 3 1 x 1 3 Probe 132 x 38 x
2. 1 27 2010 15 30 02 1 27 2010 15 31 40 1 27 2010 15 32 15 1 27 2010 15 34 43 1 27 2010 15 34 57 1 27 2010 15 36 14 EL 1 97 2910 CHA01001 47 6 47 6 48 48 4 48 7 49 2 47 6 46 5 45 8 45 39 9 38 4 37 4 36 2 28 7 28 7 28 27 6 27 2 26 5 26 5 25 6 25 4 25 3 DEGREE E E G H I Ch1 Value Ch1 Unit Ch2 Value Ch2_unit Ch3 Value Ch3_unit RH 72 2 DEGREE F 1086 PPM RH 72 1 DEGREE F 1077 PPM RH 72 1 DEGREE F 1186 PPM RH 72 DEGREE F 1106 PPM RH 71 9 DEGREE F 1106 PPM RH 71 8 DEGREE F 1055 PPM RH 72 3 DEGREE F 1063 PPM RH 72 5 DEGREE F 1040 PPM RH 72 7 DEGREE F 1106 PPM RH 72 7 DEGREE F 1114 PPM RH 72 7 DEGREE F 1121 PPM RH 72 7 DEGREE F 1126 PPM RH 72 7 DEGREE F 1125 PPM RH 72 7 DEGREE F 1108 PPM RH 80 2 DEGREE F 892 PPM RH 80 2 DEGREE F 895 PPM RH 81 3 DEGREE F 858 PPM RH 81 8 DEGREE F 883 PPM RH 82 4 DEGREE F 880 PPM RH 83 2 DEGREE F 871 PPM RH 83 5 DEGREE F 900 PPM RH 84 6 DEGREE F 874 PPM RH 84 7 DEGREE F 863 PPM RH 85 2 DEGREE F 843 PPM e 2 p 252 DOM SD800 EU EN V2 6 07 13 Advanced Settings The SET function is used to accomplish the following 10 11 Format the SD memory card Set the date and time Set the sampling time Set the beeper sound ON OFF Set the SD card Decimal character Select the Temperature units Set the RS232 data output ON OFF Set CO height compensation in meters Set CO height compensation in feet Press and
3. 32mm 5 2 x 1 5 x 1 3 Range Resolution Accuracy of reading Temperature 0 0 to 50 0 C 0 1 C 0 8 C 32 0 to 122 0 F 0 1 F 1 5 F Relative Humidity 10 to 70 4 RH 0 1 70 to 90 i 4 of reading 1 RH co lt 1000ppm 40ppm gt 1000 to lt 3000ppm 1ppm 5 of reading gt 3000ppm 250ppm typical Note Above specification tests under the environment RF Field Strength less than 3 V M amp frequency less than 30 MHz only Copyright O 2013 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com 7 SD800 EU EN V2 6 07 13
4. C and press ENTER to store the selection rS232 Set the RS232 data output ON OFF Press the A button to select ON or off and press Enter to store the selection High Set the height compensation for CO in meters Press the A or W buttons to adjust the selected field to the height altitude of the measurement site This adjustment will improve measurement accuracy HIghF Set the height compensation for CO in feet Press the A or Y buttons to adjust the selected field to the height altitude of the measurement site This adjustment will improve measurement accuracy ESC Exit the setting mode Press the SET button to return to normal operation System RESET If a condition appears where the CPU does not respond to keystrokes or the meter seems frozen press the RESET button on the side of the datalogger use a paper clip or similar pointed object to return the meter to a working state 5 SD800 EU EN V2 6 07 13 RS232 Interface A serial output is provided to link the meter to a PC s serial port Call Technical Assistance for more information on this interface Battery Warning Installation and Replacement 1 When the AC adaptor is not connected and the DI low battery icon appears in the display the batteries are weak and should be replaced To replace or install batteries remove the Philips head screw that secures the rear battery cover and lift off the cover Replace the six AAA batteries use alkaline heavy duty type
5. EXTECH USER GUIDE INSTRUMENTS CO Humidity Temperature Datalogger Model SD800 Intro duction Congratulations on your purchase of the Extech SD800 CO Temperature Humidity Datalogger This meter measures displays and stores CO temperature and relative humidity readings Data is store d on a SD card for transfer to a PC This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Features LCD simultaneously displays Carbon Dioxide Temperature and Relative Humidity Datalogger date time stamps and stores readings on an SD card in Excel format for easy transfer to a PC Selectable data sampling rate 5 10 30 60 120 300 600 seconds Product Description aio 0 Tor E E Ne 11 12 13 14 15 Humidity Temperature Sensor Humidity Display Temperature Display CO2 Display LOG ENTER button SET button AC adaptor socket CO2 probe socket A TIME button Y button Reset button RS 232 output SD memory card socket CO probe CO plug Note Battery Compartment and Tilt Stand are located on the back of the meter 2 SD800 EU EN V2 6 07 13 Operation Setup 1 Connect the CO probe to the datalogger by inserting the plug into the connector on the bottom of the datalogger Connect the AC adaptor to the datalogger by insertin
6. Hold the SET button for gt 2 seconds to enter the setting mode The first function Sd F will appear in the display Press the SET button to step through the seven functions Use the A and Y buttons to adjust the selected function Use the LOGGER button to step through fields within a function In the SET mode if no button is pressed within 5 seconds the logger will revert to the standard mode Sd F Format the SD card Press the A button to select yES or no For yES press the Enter button When yES and Ent appear press the Enter key again to format the card and erase all existing data The screen will display a flashing yEs and ESC while the memory is being erased and formatted dAtE Set the date and time Press the A or Y buttons to adjust the selected field Press the Enter button to store the value and to step through the various fields SP t Set the sample rate Press the A button to select the desired sample rate and press Enter to store the selection The selections are 5 10 30 60 120 300 600 seconds and AUTO In AUTO the data will be stored every time there is a temperature change of gt 1 degree gt 1 RH or gt 50 ppm DEEP Set the beeper ON or OFF Press the A button to select ON or OFF and press Enter to store the selection dEC Set the SD card Decimal character Press the A button to select USA decimal or Euro comma and press Enter to store the selection t CF Set the Temp unit to F or
7. g the plug into the connector on the bottom of the datalogger Insert the 6 AAA batteries into the battery compartment Without these batteries installed the real time clock will reset every time the ac adaptor is disconnected Datalogging 1 Open the left side door and insert a formatted SD card Note The SD card should be at least 1GB in capacity 4GB to 16GB recommended Note Do not use memory cards formatted by other meters or cameras Use the SD card formatting procedure under the advanced features section of this manual to correctly format the card Note The internal clock must be set to the correct time See the advanced features section of this manual to set the clock Note The default data structure uses a decimal point as the numeric decimal indicator See the advanced features section of this manual to change this to a comma Note If the SD memory card is not installed EMPTY will appear in the display Note Displayed error messages CH CArd 2 The memory card is full or there is a problem with the card LobAt The battery is low No CArd The SD card is not inserted Press the LOGGER button for gt 2 seconds to begin logging DATALOGGER will appear in the display and the meter will beep each time the data is recorded if the beeper is enabled To stop datalogging press the LOGGER button for gt 2 seconds DATALOGGER will change to DATA and the meter will count down
8. through the recorded data NOTE To avoid corrupting data do not remove the memory card without properly ending the record function Time Date Sample Rate Check Press and Hold the TIME button for gt 2 seconds and the display will cycle through the date time and sample rate information 3 SD800 EU EN V2 6 07 13 SD Card Data Structure When the SD card if first inserted into the datalogger the folder CHAO1 is created 2 The first datalogging session will then create a file CHA01001 XLS All data will be saved to this file until the number of columns reaches 30 000 3 After 30 000 columns a new file CHA01002 XLS is created This is repeated every 30 000 columns until CHA01099 XLS At this point a new folder CHA02 is created and the process is repeated CHA10 is the final folder Transferring Data to a PC 1 Remove the memory card from the datalogger and plug it into the SD card slot on the PC 2 Launch Excel and open the data file on the memory card from within the spreadsheet program The file will appear similar to the figure below ar B c I Position Date Time 1 27 2010 14 14 32 1 27 2010 14 14 33 1 27 2010 14 14 40 1 27 2010 14 14 54 1 27 2010 14 15 16 1 27 2010 14 17 36 1 27 2010 14 39 04 1 27 2010 14 52 40 1 27 2010 15 07 27 1 27 2010 15 07 34 1 27 2010 15 07 41 1 27 2010 15 07 48 1 27 2010 15 08 02 1 27 2010 15 08 16 1 27 2010 15 26 03 1 27 2010 15 26 09 1 27 2010 15 28 02 1 27 2010 15 28 58