Home

1045 - VWR International

image

Contents

1. Minutes will flash Press START STOP button to advance minutes to desired time Note Press and hold START STOP button to advance minutes rapidly 5 Press SPLIT RESET again Hours will flash Press START STOP button to advance hours to desired time Note Press and hold START STOP button to advance hours rapidly Note A next to minutes indicates A M P next to minutes indicates P M Note To display time in 24 hour format press START STOP button until H appears next to minutes 6 Press SPLIT RESET again DATE will appear on right hand side of display Number will flash Press START STOP to advance number to today s date Note Press and hold START STOP button to advance numbers rapidly 7 Press SPLIT RESET again Number will flash Press START STOP to advance number to desired month Note Press and hold START STOP button to advance numbers rapidly 8 Press SPLIT RESET again Bars will flash under days of week SU MO TU WE TH FR SA Press START STOP until bar is flashing under desired day 9 When desired time date month and day are set press MODE to save changes 10 To view day date month on display in time mode press and hold START STOP button Set Alarm 1 Press MODE until alarm time appears Bar under MO and hour number will flash 2 Press START STOP button to desired hour Note Press and hold START STOP button to advance hours rapidly 3 Press SPLIT RESET button again Minute numbers will flash 4 Press START S
2. to zero and begin counting up again Cumulative Split Timing 1 Press MODE button until three flashing bars appear on display under SU FR and SA 2 Press SPLIT RESET button to clear display to zero Display should read 0 00 00 3 Press START STOP button once to begin timing event 4 Press SPLIT RESET once to freeze display and take split time reading Note Flashing colon indicates internal clock is still running 5 Press SPLIT RESET button again to resume timing Note Display instantly updates to show cumulative running time 6 Any number of split time readings may be taken during a timing event 7 Toend timing event completely press START STOP then press SPLIT RESET to return display to 0 00 00 Timing Two Events 1 Press MODE button until three flashing bars appear on display under SU FR and SA Press SPLIT RESET button to clear display to zero Display should read 0 00 00 Press START STOP button once to begin timing events Press SPLIT RESET when first event ends Press STOP START when second event ends Display will show total time of first event Press SPLIT RESET one time Display will show total time of second event Press SPLIT RESET to return display to zero ANDO WP Set Time of Day and Date 1 Press MODE button until clock mode appears 2 Time of day will appear Seconds and bar under TU will flash 3 Press START STOP button to set seconds to zero 4 Press SPLIT RESET
3. TOP button to desired minutes A next to minutes indicates AM P next to minutes indicates PM Note Press and hold START STOP button to advance minutes rapidly 5 When desired alarm time is set press MODE to save changes 6 To view alarm time on display in time mode press and hold SPLIT RESET button Set Alarm On or Off 1 To turn alarm on In time mode press and hold down SPLIT RESET button Alarm time will be displayed Press START STOP once BEEP will sound and alarm symbol will appear in upper right hand corner of display 2 To turn alarm off Press and hold down SPLIT RESET button again Alarm time will be displayed Press START STOP once BEEP will sound and alarm symbol will disappear from upper right hand corner of display 3 To turn off a sounding alarm press either START STOP or SPLIT RESET button Set Hourly Alarm On or Off To set alarm to BEEP once on each hour 1 Press MODE until time of day is displayed Press and hold SPLIT RESET Press MODE until all bars show SU MO TU WE TH FR SA Release SPLIT RESET button Alarm will BEEP only one time each hour To turn off alarm on the hour press and hold SPLIT RESET All bars will appear Press MODE one time all bars will disappear aon amp WwW P Set Snooze Function On or Off 1 When alarm is sounding press START STOP Alarm will stop sounding 2 After 5 minutes alarm will begin to sound again 3 Press START STOP to reset snooze function to so
4. TRACEABLE WATER SHOCK RESISTANT STOPWATCH TRACEABLE WATERPROOF SHOCKPROOF STOPWATCH SPECIFICATIONS Display 2 High LCD shows hours minutes seconds date Accuracy 0 01 Resolution 1 100 second for first 30 minutes 1 second after 30 minutes Timing Channels one Timing Capacity 23 hours 59 minutes 59 seconds count up Functions single action time out cumulative split time of day with 12 24 hour format alarm and date Alarm Audible alarm sounds for one minute Attachments Lanyard Clock yes Size 2 5 x 2 25 x 5 Weight 10z Single Action Timing 1 Press MODE button until three flashing bars appear on display under SU FR and SA 2 Press SPLIT RESET button to clear display to zero Display should read 0 00 00 3 Press START STOP button once to begin count up timing Note Bars under SU and SA continue to flash throughout timing to 30 minutes After 30 minutes only bar under SU continues to flash 4 To stop timing event press START Stop button once Note Bars continue to flash during time out 5 Press SPLIT RESET button to clear display Time in Time out Stopwatch may be paused at any time during timing event by pressing START STOP button once To resume timing press START STOP button again To end timing event completely press START STOP then press SPLIT RESET to return display to 0 00 00 Continuous Timing When timing event lasts longer than 24 hours stopwatch will roll over
5. und again in 5 minutes 4 To turn off snooze function completely press SPLIT RESET when alarm is sounding All Operational Difficulties If this stopwatch does not function properly for any reason please replace battery with a fresh high quality battery see BATTERY REPLACEMENT section Low battery power can occasionally cause any number of apparent operational difficulties Replacing battery with a fresh battery will solve most difficulties Battery Replacement An incorrect display no display or operational difficulties indicate that battery should be replaced To replace battery remove six screws on back of unit Loosen screw on BATTERY CLIP so clip can slide to gain access to battery Removed depleted battery Install fresh battery in appropriate position so that side of battery is visible Replace BATTERY CLIP Replace back of unit Replace six screws and tighten securely Replacement battery Cat No 1039 Warranty Service or Recalibration For warranty service or recalibration contact CONTROL COMPANY 4455 Rex Road Friendswood Texas 7 546 USA Ph 281 482 1714 Fax 281 482 9448 E mail sales control3 com www control3 com Control Company is ISO 9001 Quality Certified by DNV and ISO 17025 accredited as a Calibration Laboratory by A2LA Control Company Cat No 92 1042 00 92 1045 00 Rev 5 051608 Traceable is a registered trademark of Control Company 2008 Control Company

Download Pdf Manuals

image

Related Search

Related Contents

無線LAN内臓ケーブルモデム  SCADAPack Vision Operator Interface User Manual    Whitehaus Collection WH1-102R-WH Installation Guide  Capitolo 1: Antivirus Dr.Web Enterprise Security Suite  Lyngdorf Audio DPA-1 Stereo Amplifier User Manual  取扱説明書 - サンテスト    Datalogic Skorpio X3    

Copyright © All rights reserved.
Failed to retrieve file