Home

ST 3000 Smart Pressure Transmitter Series 100 Differential

image

Contents

1. 4 2nF T4 Ta 93 C LIi Pi 1 2W Nonincendive Vmax 30V Imax 225mA j o Class l Division 2 Groups A B C 722 mA HART Ca T4 Ta 93 C D locations Enclosure Type 4X Pi 1 2W Vmax 24V Fieldbus Entity eee T4 Ta 40 C Not FNICO Li 0 T3 Ta 93 C Pi 1 2W All ST 3000 models except STG19L STG99L STG170 and STG180 m Registration Number have been registered in all provinces and territories in Canada and are CRN marked CRN 0F8914 5C Association CSA 12 ST 3000 Smart Pressure Transmitter i n y Type of Protection Comm Option Field Parameters Temp Codes Flameproof Zone 1 T5 Ta 50 to 93 C Ex d IIC Enclosure IP 66 67 T6 Ta 50 to 78 C T4 Ta 50 to 93 C 4 20 mA DE T5 Ta 50 to 85 C IECEx i T6 Ta 50 to 70 C International Electrotechnical os Commission Intrinsically Safe Zone 0 1 i T4 Ta 50 to 93 C LCIE 4 20 mA HART i T5 Ta 50 to 63 C Ex ia IIC Enclosure IP 66 67 i T6 Ta 50 to 48 C Fieldbus T3 Ta 50 to 93 C Not FISCO IA T4 Ta 50 to 40 C Li 0 except Li 150uH when Option ME Analog Meter is selected ne Type of Protection Comm Option Field Parameters Temp Codes Flameproof Zone 1 All All T5 Ta 50 to 93 C Ex d IIC Enclosure IP 66 67 T6 Ta 50 to 78 C Ui 30V li 100mA T4 Ta 50 to 93 C 4 20 mA DE Ci 4 2nF T5 Ta 50 to 85 C Li T6 Ta 50 to 70 C Pi 1 2W a
2. Adapter Flanae 1 2 NPT with 316 SS Bolts 316 SS Adapter Flanae 1 2 NPT with NACE A286 SS Bolts 316 SS Adapter Flanae 1 2 NPT with B7M Bolts Hastellov C 276 Adapter Flanae 1 2 NPT with CS Bolts Hastellov C 276 Adapter Flanae 1 2 NPT with 316 SS Bolts Monel 400 Adapter Flanae 1 2 NPT with CS Bolts Monel 400 Adapter Flanae 1 2 NPT with 316 SS Bolts 316 SS Blind Adapter Flanae with CS Bolts 316 SS Blind Adapter Flanae with 316 SS Bolts 316 SS Blind Adapter Flanae with NACE A286 SS Bolts 316 SS Blind Adapter Flanae with B7M Bolts Side Vent Drain End Vent Drain is standard 316 SS Center Vent Drain and Bushing 3 Hastellov C 276 or UNS N10276 4 Monel 400 or UNS N04400 5 Supplied as 316 SS or as Grade CF8M the castina eauivalent of 316 SS Supplied as indicated or as Grade CW12MW the castina eauivalent of Hastellov C 276 T Supplied as indicated or as Grade M30C the castina eauivalent of Monel 400 8 Viton or Fluorocarbon Elastomer o o o Table Ill Options continued on next page N ST 3000 Smart Pressure Transmitter 34 ST 16U 01 Issue 66 Page 3 of 5 Availability STD1xx VVV vv TABLE Ill OPTIONS continued Selection 20 30 70 25 10 G pees Joma Viton Process Head Gaskets adapter aaskets ordered separately _ sye efe ep fee Process Head amp ee Flange Gaskets j A 17 17 171 17 17 E S E E E E Angle Mounting Bracket C
3. 4 8 3 13 amp ST 3000 Pressure 13 5 4 8 4 27 5 1 4 9 7 13 Certificate number 04 HS417416 PDA Transmitter Marine Certificate Bureau Veritas BV Product Code 389 1H Certificate number 12660 BO BV MT Option Det Norske Veritas DNV Location Classes Temperature D Humidity B Vibration A EMC B Enclosure C For salt spray exposure enclosure of 316 SST or 2 part epoxy protection with 316 SST bolts to be applied Certificate number A 11476 Korean Register of Shipping KR Certificate number LOX17743 AE001 Lloyd s Register LR Certificate number 02 60001 E1 amp E2 ST 3000 Smart Pressure Transmitter European Pressure Equipment Directive PED 97 23 EC CE Mark Dual Seal Certification Recommended Frequency of Calibration Approved Manufacturing Locations 19 The ST 3000 Smart Pressure Transmitters are in conformity with the essential requirements of the Pressure Equipment Directive Honeywell ST 3000 Smart Pressure Transmitters are designed and manufactured in accordance with the applicable portions of Annex Essential Safety Requirements and sound engineering practices These transmitters have no pressurized internal volume or have a pressurized internal volume rated less than 200 bar 2 900 psig and or have a maximum volume of less than 0 1 liter Article 3 1 1 a first indent Group 1 fluids Therefore these transmitters are not subject to the essential requirements of the direct
4. Enclosure IP 66 67 Ex d IIC T5 Ta 40 C to 93 C T6 Ta 40 C to 78 C Supply 11 42Vdc Ex tD A21 IP6X T95 C at Ta 93 C or T80 C at Ta 78 C Enclosure IP 66 67 Ex nA IIC T5 Ta 40 C to 93 C T6 Ta 40 C to 78 C Zone 2 Supply lt 42Vdc 23mA Ex tD A22 IP6X T95 C at Ta 93 C or T80 C at Ta 78 C Honeywell Enclosure IP 66 67 Ex ia IIC T4 Ta 50 C to 93 C T5 Ta 50 C to 85 C T6 Ta 50 C to 70 C Ui 30V li 100mA Ex tD A20 IP6X T95 C at Ta 93 C or T80 C at Ta 78 C Ex d IIC T5 Ta 40 C to 93 C T6 Ta 40 C to 78 C Supply 11 42Vdc Ex tD A21 IP6X T95 C at Ta 93 C or T80 C at Ta 78 C Ex nA IIC T5 Ta 40 C to 93 C T6 Ta 40 C to 78 C Zone 2 Supply lt 42Vdc 23mA Ex tD A22 IP6X T95 C at Ta 93 C or T80 C at Ta 78 C Honeywell Enclosure IP 66 67 b 3N 10 See ATEX installation requirements in the ST 3000 User s Manual 11 The user must determine the type of protection required for installation of the equipment The user shall then check the box V adjacent to the type of protection used on the equipment certification nameplate Once a type of protection has been checked on the nameplate subsequently the equipment shall not be reinstalled using any of the other certification types ST 3000 Smart Pressure Transmitter 34 ST 16U 01 Issue 66 Pag
5. T4 Ta 50 to 40 C nameplate Once a type of protection has been checked on the nameplate subsequently the equipment shall not be reinstalled using any of the other certification types Li 0 except Li 150UH when Option ME Analog Meter is selected 14 ST 3000 Smart Pressure Transmitter Sys Type of Protection Comm Option Field Parameters Temp Codes Flameproof Zone 1 T5 Ta 50 to 93 C BR Ex d IIC T6 Ta 50 to 78 C Enclosure IP 66 67 T4 Ta 50 to 93 C 4 20 mA DE i T5 Ta 50 to 85 C INMETRO i T6 Ta 50 to 70 C CERTUSP Brazil ee Intrinsically Safe Zone 0 1 y li 100mMA T4 Ta 50 to 93 C 4 20 mA HART Ci 4 2nF T5 Ta 50 to 63 C BR Ex ia IIC ee T6 Ta 50 to 48 C Enclosure IP 66 67 1 2W i Ui 24V li 250MA R P Fieldbus Ci 4 2nF T3 Ta 50 to 93 C Not FISCO eG T4 Ta 50 to 40 C Pi 1 2W Li 0 except Li 150uH when Option ME Analog Meter is selected This certificate defines the certifications covered for the ST 3000 Pressure Transmitter family of products including the SMV 3000 Smart Multivariable Transmitter It represents the compilation of the five certificates Honeywell currently has covering the certification of these products into marine applications For ST 3000 Smart Pressure Transmitter and SMV 3000 Smart Multivarible Transmitter American Bureau of Shipping ABS 2009 Steel Vessel Rules 1 1 4 3 7 4 6 2 5 15
6. inH O effect equals 10 inH O 25 mbar 0 2375 0 25 or 0 2375 0 25 _ in of span span inH O span mbar In Digital Mode 0 4625 of span For URV below reference point 10 inH O effect equals 10 inH O 25 mbar 0 2125 0 25 or 0 2125 0 25 in of span span inH O span mbar Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm ST 3000 Smart Pressure Transmitter Performance Under Rated Conditions Model STD120 0 to 400 inH QO Parameter Description Upper Range Limit inH O 400 39 2 F 4 C is standard reference temperature for inH O range mbar 1 000 Minimum Span inH O 1 Note Recommended minimum span in square root mode is 20 inH O 50 mbar mbar 2 5 Turndown Ratio 400 to 1 Zero Elevation and No limit except minimum span within 100 URL Specifications valid from 5 to Suppression 100 URL Accuracy Reference Includes In Analog Mode 0 0525 of calibrated span or upper range value URV whichever combined effects of linearity hysteresis and repeatability e Accuracy includes residual error after averaging successive readings For FOUNDATION Fieldbus use Digital Mode specifications For HART use Analog Mode specifications is
7. mA DE Intrinsically Safe Zone 0 1 ll 1G Ex ia IIC Enclosure IP 66 67 T4 Ta 50 to 93 C T5 Ta 50 to 85 C T6 Ta 50 to 70 C All All li 100mA 4 20 mA HART Ci 4 2nF Li Pi 1 2W T4 Ta 50 to 93 C T5 Ta 50 to 63 C T6 Ta 50 to 48 C Fieldbus T3 Ta 50 to 93 C T4 Ta 50 to 40 C Not FISCO Ui 30V li 100mA 4 20 mA DE Ci 4 2nF Li Pi 1 2W T4 Ta 50 to 93 C T5 Ta 50 to 85 C T6 Ta 50 to 70 C T4 Ta 50 to 93 C T5 Ta 50 to 63 C T6 Ta 50 to 48 C Non Sparking Zone 2 Ui 30V ATEX ee 4 20 mA HART i 4 2 LCIE l 3 G Ex nA IIC Honeywell m mg Enclosure IP 66 67 Pi 1 2W Fieldbus T3 Ta 50 to 93 C T4 Ta 50 to 40 C Not FNICO Multiple Marking Ui 30V li 100MmA Flameproof Zone 1 4 20 mA DE eal E912 G Ex d IIC Pi 1 2W T4 Ta 50 to 93 C T5 Ta 50 to 85 C T6 Ta 50 to 70 C Intrinsically Safe Zone 0 1 Ui 30V Aa ia IIC li 100mMA T4 Ta 50 to 93 C Ell 1G 4 20 mA HART Ci 4 2nF T5 Ta 50 to 63 C Li T6 Ta 50 to 48 C Non Sparking Zone 2 Pi 1 2W Ell 3 G Ex nA IIC NOTE The user must determine the type of protection required for installation of the equipment The user shall then check the box V adjacent to the type of protection Fieldbus T3 Ta 50 to 93 C used on the equipment certification Not FISCO FNICO
8. water service due to hydrogen migration For that service use 316 stainless steel wetted Process Heads Hastelloy C 276 or UNS N10276 Supplied as indicated or as Grade CW12MW the casting equivalent of Hastelloy C 276 7 Monel 400 or UNS N04400 Supplied as indicated or as Grade M30C the casting equivalent of Monel 400 Monel 400 or UNS N04400 or UNS N04405 10 ST 3000 Smart Pressure Transmitter Certifications ay Type of Protection Comm Option Field Parameters Temp Codes Explosionproof Class Division 1 Groups A B C D locations Dust Ignition Proof All All T5 Ta 93 C Class Il Ill Division 1 Groups E F G locations Enclosure Type 4X Vmax 42 4V Imax 225mA Sk 4 20 mA DE Ci 4 2nF T4 Ta 93 C Intrinsically Safe li Pi 1 2W Class I Il III Division 1 Groups A B C D E F G locations Enclosure Vmax 30V Type 4X Imax 225mA 4 20 mA Ci 4 2nF T4 Ta 93 C i Pi 1 2W Vmax 32V Fieldbus Entity ee T4 Ta 40 C Not FISCO oa T3 Ta 93 C Intrinsically Safe Pi 0 84W a Vmax 24V glass ee Division 1 Groups Fieldbus Entity oe T4 Ta 40 C ie Not FISCO T3 Ta 93 C Li 0 FM Class 1 Zone 0 AEx ia Group IIC Pi 1 2W Approvals gt Enclosure Type 4X IP 66 67 Vmax 17 5V Imax 380mA a FISCO Ci 4 2nF T4 Ta 40 C 920 on T3 Ta 93 C Pi 5 32W Vmax 42 4V Imax 225mA 4 20 mA DE Ci 4 2nF T4 Ta 93 C
9. 0 inH O effect equals 50 inH O 125 mbar 0 025 0 2 or 0 025 0 2 in of span span inH O span mbar Zero Static Pressure Effect per 1 000 psi 70 bar 0 075 of span For URV below reference point 50 inH O effect equals 50 inH O 125 mbar 0 0125 0 0625 ___ span inH O Or o 0125 0 0625 in of span span mbar Combined Zero and Span Static Pressure Effect per 1 000 psi 70 bar 0 15 of span For URV below reference point 50 inH O effect equals 50 inH O 125 mbar 0 0875 0 0625 or 0 0875 0 0625 _ in of span span inH O span mbar Stability 0 01 of URL per year for lifetime Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm ST 3000 Smart Pressure Transmitter Performance Under Rated Conditions Model STD125 0 to 600 inH QO Parameter Description Upper Range Limit inH20 600 39 2 F 4 C is standard reference temperature for inH O range mbar 1 500 Minimum Span inH2O 6 mbar 15 Turndown Ratio 100 to 1 Zero Elevation and Suppression No limit except minimum span within 0 to 100 URL Accuracy Reference Includes combined effects of linearity hysteresis and repeatability e Accuracy includes residual error
10. 228 2012 Honeywell International Inc www honeywellprocess com
11. Conditions All Models Reference Rated Condition Operative Limits Transportation and Parameter ape Condition Storage C OF C OF C OF C OF Ambient Temperature STD110 2541 7742 15 to 65 5 to 150 40 to 70 40 to 158 40 to 70 40 to 158 STD125 2541 7742 40 to 85 40to185 40to85 40 to 185 55 to 125 67 to 257 STD120 STD130 STD170 2541 77 2 40 to 85 40to185 40to93 40 to 200 55 to 125 67 to 257 Meter Body Temperature STD110 2541 7742 15 to 65 5 to 150 40 to 70 40 to 158 40 to 70 40 to 158 STD125 2541 7742 40 to 85 40to185 40to85 40 to 185 55 to 125 67 to 257 STD120 STD130 STD170 25 1 77 2 40 to 110 40 to 230 40 to 125 40 to 257 55 to 125 67 to 257 Humidity RH 10 to 55 O to 100 O to 100 O to 100 Vac Region Min Pressure All Models Except STD110 mmHg absolute Atmospheric 25 2 short term inH O absolute Atmospheric 13 1 short term Supply Voltage Current and Load Resistance Voltage Range 10 8 to 42 4 Vdc at terminals Current Range 3 0 to 21 8 mA Load Resistance 0 to 1 440 ohms as shown in Figure 2 Maximum Allowable Working Pressure MAWP ST 3000 products are rated to Maximum Allowable Working Pressure MAWP depends on Approval Agency and transmitter materials of construction STD110 50 psi 3 45 bar STD120 STD125 STD130 and STD170 4 500 psi 310 bar Static Pre
12. Distributor contact one of the offices below ASIA PACIFIC EMEA NORTH AMERICA SOUTH AMERICA TAC hfs tac Phone 80012026455 or 44 Honeywell Process Solutions Honeywell do Brazil amp Cia support honeywell com 0 1202645583 Phone 1 800 423 9883 Phone 55 11 7266 1900 l FAX 44 0 1344 655554 Or 1 800 343 0228 FAX 55 11 7266 1905 a TEN Email Sales sc cp apps Email Sales ask Email Sales ask sa ae r salespa62 honeywell com ssc honeywell com or ssc honeywell com or Phone 61 7 3846 1255 or FAX 61 7 3840 6481 TAC hfs tac TAC hfs tac TAC hfs tac support honeywell com support honeywell com Toll Free 1300 36 39 36 support honeywell com Toll Free Fax 1300 36 04 70 China PRC Shanghai Honeywell China Inc Phone 86 21 5257 4568 Fax 86 21 6237 2826 Singapore Honeywell Pte Ltd Phone 65 6580 3278 Fax 65 6445 3033 South Korea Honeywell Korea Co Ltd Phone 822 799 6114 Fax 822 792 9015 Specifications are subject to change without notice For More Information Learn more about how Honeywell s ST 3000 Smart Pressure Transmitters can increase performance reduce downtime and decrease configuration costs visit our website www honeywellprocess com pressure transmitters or contact your Honeywell account manager Honeywell Honeywell Process Solutions 1860 West Rose Garden Lane a 34 ST 03 60 Phoenix Arizona 85027 October 2012 Tel 1 800 423 9883 or 1 800 343 0
13. Nonincendive Li Pi 1 2W Class Division 2 Groups A B C D Vmax 30V locations Enclosure Type 4X Imax 225mA 4 20 mA HART Ci 4 2nF T4 Ta 93 C Li Pi 1 2W Vmax 32V Nonincendive Fieldbus Entity ile T4 Ta 40 C Not FNICO ee T3 Ta 93 C Pi 0 84W Class Division 2 Groups A B C D Vmax 24V Suitable for Fieldbus Entity ia Toii T4 Ta 40 C Class II Division 2 Groups F amp G Not FNICO Li 0 T3 Ta 93 C Class lIl Division 2 Pi 1 2W Class l Zone 2 Group IIC Enclosure Type 4X IP 66 67 FNICO T4 Ta 40 C T3 Ta 93 C Li 0 except Li 150UH when Option ME Analog Meter is selected FM Approvals gt is a service mark of FM Global ST 3000 Smart Pressure Transmitter 11 fi ul Type of Protection Comm Option Field Parameters Temp Codes Explosion Proof Class Division 1 Groups B C D locations Dust Ignition Proof Class Il Ill ee Division 1 Groups E F G i ii A locations Enclosure Type 4X Vmax 42V Imax 225mA 4 20 mA DE Ci 4 2nF T4 Ta 93 C Li Pi 1 2W Intrinsically Safe Vmax 42V Imax 225mA Class Il Ill Division 1 Groups A 4 20 mA HART Ci 4 2nF T4 Ta 93 C B C D E F G locations Li Enclosure Type 4X Pi 1 2W Vmax 24V Canadian Imax 250mA Fieldbus Entity Ci 4 2nF T4 Ta 40 C Standards Not FISCO T3 Ta 93 C Li 0 Pi 1 2W Vmax 42 4V Imax 225mA 4 20 mA DE Ci
14. RV whichever is greater terminal based For URV below reference point 300 psi accuracy equals 300 psi 21 bar 0 0 05 0 10 OF 0 05 0 10 in of span span psi span bar In Digital Mode 0 125 of calibrated span or upper range value URV whichever is greater terminal based For URV below reference point 300 psi accuracy equals 300 psi 21 bar 0 025 0 10 or 0 025 0 10 2 in of span span psi span bar Zero Temperature Effect per 28 C 50 F In Analog Mode 0 1125 of span For URV below reference point 500 psi effect equals 00 psi 35 bar 5 0 0125 0 10 or 0 0125 0 10 in of span span psi span bar In Digital Mode 0 10 of span For URV below reference point 500 psi effect equals 500 psi 35 bar o 0 10 _ or 0 10 _ in of span span psi span bar Combined Zero and Span Temperature Effect per 28 C 50 F In Analog Mode 0 175 of span For URV below reference point 500 psi effect equals 0 psi 35 bar 50 5 0 0754 0 10 or 0 075 0 10 in of span span psi span bar In Digital Mode 0 15 of span For URV below reference point 500 psi effect equals psi 35 bar 500 np 0 05 0 10 or 0 05 0 10 in of span span psi span bar Zero Static Pressure Effect per 1 000 psi 70 ba
15. T4 Ta 50 to 93 C S aoe eae es 4 20 mA HART T5 Ta 50 to 63 C x ia IIC Enclosure T6 Ta 50 to 48 C Fieldbus T3 Ta 50 to 93 C Not FISCO T4 Ta 50 to 40 C tier Multiple Marki Ui 30V i ultiple Marking i pepe as li 100mA T4 Ta 50 to 93 C Flameproof Zone 1 4 20 mA DE Ci 4 2nF T5 Ta 50 to 85 C J Pg oe 3 Ex d IIC Enclosure IP 66 67 aa T6 Ta 50 to 70 C Pi 1 2W Intrinsically Safe Zone 0 1 Ui 30V i Ex ia IIC Enclosure IP 66 67 li 100mA T4 Ta 50 to 93 C 4 20 mA HART Ci 4 2nF T5 Ta 50 to 63 C j ae 0 The user must determine the type of a 4 OW T6 Ta 50 to 48 C protection required for installation of i the equipment The user shall then check the box V adjacent to the type of protection used on the equipment certification nameplate Once a type of protection has been checked on the nameplate subsequently the equipment shall not be reinstalled using any of the other certification types Fieldbus T3 Ta 50 to 93 C Not FISCO T4 Ta 50 to 40 C Li 0 except Li 150uH when Option ME Analog Meter is selected ST 3000 Smart Pressure Transmitter 13 i Type of Protection Comm Option Field Parameters Temp Codes Flameproof Zone 0 Il 1D Ex tD All A20 IP6X T95 C Ta Enclosure IP 66 67 Poe Ue E sees Flameproof Zone 1 e iN 2 ee Il2 GD Ex d IIC Ex tD All Ao TN le Enclosure IP 66 67 93 C or T80 C Ta 78 C 4 20
16. Technical Information Honeywell ST 3000 Smart Pressure Transmitter Series 100 Differential Pressure Models a Se a pm e I I an Specifications 7 34 ST 03 60 October 2012 S43 as Introduction In 1983 Honeywell introduced the first Smart Pressure Transmitter the ST 3000 In 1989 Honeywell launched the first all digital bi directional protocol for smart field devices Today its ST 3000 Series 100 Differential Pressure Transmitters continue to bring proven smart technology to a wide spectrum of pressure measurement applications from furnace combustion airflow rate to hydrostatic tank gauging The ST 3000 Series 100 S100 Differential Pressure Transmitter can be used with any primary flow element to provide proven repeatable flow measurement STD110 O to 10 inH2O 0 to 25 mbar Figure 1 Series 100 Differential Pressure Transmitters feature STD120 0 to 400 inH20 0 to 1 000 mbar field proven piezoresistive sensor technology STD125 O to 600 inH20 0 to 1 500 mbar STD130 O to 100 psi 0 to 7 bar When digitally integrated with Honeywell s Experion Process Knowledge System or other TDC TPS systems STD170 0 to 3 000 psi O to 210 bar ST 3000 instruments provides local measurement accuracy to the system level without adding typical A D and D A converter inaccuracies as well as providing advantages All ST 3000 transmitters can be ordered to provide o
17. adings For FOUNDATION Fieldbus use Digital Mode specifications For HART use Analog Mode specifications In Analog Mode 0 075 of calibrated span or upper range value URV whichever is greater terminal based For URV below reference point 15 psi accuracy equals psi 15 nO 0 025 0 05 or 0 025 0 05 in of span span psi In Digital Mode 0 0625 of calibrated span or upper range value URV whichever is greater terminal based For URV below reference point 15 psi accuracy equals psi 15 sfooizssoo ER or sonas 009 1 bar span bar bar in of span Zero Temperature Effect per 28 C 50 F span psi In Analog Mode 0 0625 of span For URV below reference point 30 psi effect equals ps 30 0 0125 0 05 i or 00125008 span psi In Digital Mode 0 05 of span For URV below reference point 30 psi effect equals 2 bar 0 05 OF 0 05 span bar 2 in of span span bar 30 psi Combined Zero and Span Temperature Effect per 28 C 50 F __ _ in of span span psi span bar In Analog Mode 0 10 of span For URV below reference point 30 psi effect equals 008 004 2 or 005 000 J in of span span psi In Digital Mode 0 075 of span For URV below reference point 30 psi effect equals ps 30 0 025 0 05 2 bar span bar bar al in of sp
18. after averaging successive readings e For FOUNDATION Fieldbus use Digital Mode specifications For HART use Analog Mode specifications In Analog Mode 0 075 of calibrated span or upper range value URV whichever is greater terminal based For URV below reference point 25 inH O accuracy equals 25 inH O 62 mbar 0 0375 0 0375 Or 0 0375 0 0375 _ _ in of span spaninH O span mbar In Digital Mode 0 05 of calibrated span or upper range value URV whichever is greater terminal based For URV below reference point 25 inH O accuracy equals 25 inH O 62 mbar 0 0125 0 0375 2 _ or 0 0125 0 0375 _ in of span span inH O span mbar Zero Temperature Effect per 28 C 50 F Combined Zero and Span Temperature Effect per 28 C 50 F Zero Static Pressure Effect per 1 000 psi 70 bar In Analog Mode 0 2125 of span For URV below reference point 50 inH O effect equals 50 inH O 125 mbar 0 0125 0 2 or 0 0125 0 2 __ in of span span inH O span mbar In Digital Mode 0 2 of span For URV below reference point 50 inH O effect equals 50 inH O 125 mbar o 0 2 or 9 2 __ in of Span span inH O span mbar In Analog Mode 0 25 of span For URV below reference point 50 inH O effect equals inH 0 05 0 2 Or or 0 05 0 2 125 mb
19. an Zero Static Pressure Effect per 1 000 psi 70 bar Combined Zero and Span Static Pressure Effect per 1 000 psi 70 bar or 002s soos 0 075 of span span psi For URV below reference point 30 psi effect equals 30 psi 2 bar or 00125 o0z span bar span bar j in of span j in of span 0 0125 0 0625 span psi 0 15 of span For URV below reference point 30 psi effect equals 30 psi ar 2b OF 08 poeza 2 0 0875 0 0625 span bar span psi Stability 0 04 of URL per year Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm ST 3000 Smart Pressure Transmitter Performance Under Rated Conditions Model STD170 0 to 3 000 psi Parameter Description Upper Range Limit psi 3 000 bar 210 Minimum Span psi 30 bar 2 1 Turndown Ratio 100 to 1 Zero Elevation and Suppression No limit except minimum span within 0 6 and 100 URL Specifications valid over this range Accuracy Reference Includes combined effects of linearity hysteresis and repeatability e Accuracy includes residual error after averaging successive readings For FOUNDATION Fieldbus use Digital Mode specifications For HART use Analog Mode specifications In Analog Mode 0 15 of calibrated span or upper range value U
20. ar in of Span span inH O span mbar In Digital Mode 0 225 of span For URV below reference point 50 inH O effect equals 50 inH O 125 mbar 0 025 0 or 0 025 0 2 _ in of span span inH O span mbar 0 075 of span For URV below reference point 50 inH O effect equals 50 inH 20 125 mbar 0 0125 0 0625 or J o 0125 0 0625 in of span span inH O span mbar Combined Zero and Span Static Pressure Effect per 1 000 psi 70 bar 0 20 of span For URV below reference point 50 inH O effect equals 50 inH O 125 mbar over n aosa SeS Or 017s oeza meer in of span span inH O span mbar Stability 0 015 URL per year Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm ST 3000 Smart Pressure Transmitter Performance Under Rated Conditions Model STD130 0 to 100 psi Parameter Description Upper Range Limit psi 100 bar 7 Minimum Span psi 1 bar 0 07 Turndown Ratio 100 to 1 Zero Elevation and Suppression No limit except minimum span within 18 and 100 URL Specifications valid from 5 to 100 URL Accuracy Reference Includes combined effects of linearity hysteresis and repeatability e Accuracy includes residual error after averaging successive re
21. arbon Steel Marine Approved Angle Mounting Bracket Carbon Steel Angle Mounting Bracket 304 SS Marine Approved Angle Mounting Bracket 304 SS Flat Mounting Bracket Carbon Steel Gold nea aa on 316 SS User s Manual Paper Copy Standard HC H6 or FF ships accordingly Clean Transmitter for Oxygen or Chlorine Service with Certificate 50039190 Over Pressure Leak Test with Certificate F3392 Calibration Test Report and Certificate of Conformance F3399 Certificate of Conformance F3391 Certificate of Origin FO195 SIL Certificate SIL 2 3 FC33337 NACE Certificate Process Wetted amp Non Process Wetted FC33339 NACE Certificate Process Wetted only FC33338 Material Traceability Certification per EN 10204 3 1 FC33341 pe Approvals DNV ABS BV KR amp LR Warranty Options Additional Warranty 1 year Additional Warranty 2 years Additional Warranty 3 years Additional Warranty 4 years Lifetime Warranty 15 years No hazardous location approvals FM Approvals oa Ll Canadian Explosion Proof Class l Div 1 Groups B C D Standards A ore Dust Ignitionproof Class Il Ill Div 1 Groups E F G 2J ssociation CSA Intrinsically Safe Class I Il Ill Div 1 Groups A B C D E F G Flameproof Ex d IIC TS Ta 40 C to 93 C Zone 1 T6 Ta 40 C to 78 C IECE CA eee lns calsa Ex ia IIC T3 T4 T5 T6 See Spec for detailed Zone 0 1 temperature codes by Communications option Intrinsica
22. e 5 of 5 Availability VV VV 4d TABLE IV Selection 20 30 70 25 10 Factory Identification _XXXX eojojojojo RESTRICTIONS Restriction Available Only With Not Available With OOOO ctecton rane Sector b Select only one option from this group C a A Ie pg This approval code requires the selection of a certified conduit plug A5 A6 or A7 a a oe a a a Ee a E a Om COCO a a Oo oe lua cRsapsSOdSC lt C C d S SOOO Tp m coreeaawe m Fo O STD1xx TC ME FISCO FNICO compliance available only FISCO FNICO compliance not available with 1C with 2J 3C 3N 33 3S CA Z2 ZD ZA EEE a T Ie we FF SM ae E o ee MX SX ar FE WE SB This approval code requires the selection of a certified conduit plug A5 A6 or A7 Ordering Example STD120 A1A 00000 AN 1C XXXX Hastellov is a reaistered trademark of Havnes International Viton is a reaistered trademark of DuPont Performance Elastomers Monel 400 is a reaistered trademark of Special Metals Corporation Teflon is a reaistered trademark of DuPont HART is a reaistered trademark of HART Communication Foundation FM Approvals is a service mark of FM Global FOUNDATION Fieldbus is a trademark of Fieldbus Foundation DC 200 is a reaistered trademark of Dow Cornina 24 ST 3000 Smart Pressure Transmitter Sales and Service For application assistance current specifications pricing or name of the nearest Authorized
23. greater terminal based For URV below reference point 25 inH O accuracy equals 25 inH O 62 mbar 0 025 0 0275 or 0 025 0 0275 in of span span inH O span mbar In Digital Mode 0 0375 of calibrated span or upper range value URV whichever is greater terminal based For URV below reference point 25 inH O accuracy equals 25 inH O 62 mbar E 0 0125 0 025 or 0 0125 0 025 _ in of span span inH O span mbar For High Accuracy HA option 0 025 of calibrated span or upper range value URV whichever is greater terminal based Zero Temperature Effect per 28 C 50 F In Analog Mode 0 2125 of span For URV below reference point 50 inH O effect equals 50 inH O 125 mbar 0 0125 0 2 _ or 0 0125 0 2 in of span span inH O span mbar In Digital Mode 0 25 of span For URV below reference point 50 inH O effect equals 50 inH O 125 mbar o 0 2 ____ or 0 2 __ in of Span span inH O span mbar Combined Zero and Span Temperature Effect per 28 C 50 F In Analog Mode 0 25 of span For URV below reference point 50 inH O effect equals 50 inH O 125 mbar 0 05 0 2 2 _ or 0 05 0 2 in of span span inH O span mbar In Digital Mode 0 225 of span For URV below reference point 5
24. h safety systems With the SL option we are fully certified to SIL 2 capability for single transmitters and SIL 3 capability for multiple transmitter use through TUV Nord Sys Tec GmbH amp Co KG We are in compliance with the following SIL standards IEC 61508 1 1998 IEC 61508 2 2000 IEC 61508 3 1998 Lightning Protection Option LP A terminal block is available with circuitry that protects the transmitter from transient surges induced by nearby lightning strikes NAMUR NE43 Compliance Option NE This option provides software the meets the NAMUR NE43 requirements for failsafe software Transmitter failure information is generated when the measuring information is no longer valid Transmitter failure values are lt 3 6 mA and 2 21 0 mA The normal ST 3000 ranges are lt 3 8 mA and 2 20 8 mA Write Protection Options WP and WX Provides the capability to hardwire write protect installed transmitter configurations Stainless Steel Tagging Option TG Up to 30 characters can be added on the stainless steel nameplate mounted on the transmitter s electronics housing at no extra cost A stainless steel wired on tag with additional data of up to 4 lines of 28 characters is also available The number of characters for tagging includes spaces 18 ST 3000 Smart Pressure Transmitter Transmitter Configuration Options TC and FC With Option TC the factory can configure the analog DE or HART transmitter s linear square root ex
25. ia Ltd Pune 411013 India Viton is a registered trademark of DuPont Teflon is a registered trademark of DuPont Foundation Fieldbus is a trademark of the Fieldbus Foundation HART is a registered trademark of HART Communications Foundation Hastelloy C 276 is a registered trademark of Haynes International DC 200 is a registered trademark of Dow Corning Monel 400 is a registered trademark of Special Metals Corporation FM Approvals is a service mark of FM Global ST 3000 and Experion are registered trademarks of Honeywell International Inc Mounting ST 3000 Smart Pressure Transmitter Figure 3 Examples of typical mounting positions Ref Di ___ millimeters eference Dimensions a 82 9 WITH SMART METER 53 WITHOUT SMART METER 2 09 T 45 1 1 80 CAP REMOVAL CLEARANCE L E i n 9 234 8 9 24 OPTIONAL 1 2 NPT APAPTERS Figure 4 Typical mounting dimensions of STD110 STD120 STD125 STD130 amp STD170 for reference 94 9 WITH ANALOG METER 3 74 65 1 WITHOUT ANALOG METER 2 96 ROTATIONAL LOCK OPTIONAL VENT DRAIN OPTIONAL PLUG OPTIONAL ADAPTER FOR 1 2 NPT SEE DETAIL A 1 28 3 88 ST 3000 Smart Pressure Transmitter 17 Options High Accuracy Option HA Extends applicable S100 models to 0 025 analog reference accuracy Mounting Bracket Options MB MX SB SX FB The mounting bracket is available in either zinc plated carbon s
26. ive 97 23 EC PED Annex and shall not have the CE mark applied For transmitters rated gt 200 bar 2 900 psig lt 1 000 bar 14 500 psig Honeywell maintains a technical file in accordance with Annex III Module A internal production control when the CE mark is required Transmitter Attachments Diaphragm Seals Process Flanges and Manifolds comply with Sound Engineering Practice NOTE Pressure transmitters that are part of safety equipment for the protection of piping systems or vessel s from exceeding allowable pressure limits equipment with safety functions in accordance with Pressure Equipment Directive 97 23 EC article 1 2 1 3 require separate examination A formal statement from T V Industry Service Group of T V America Inc a division of TUV S ddeutschland a Notified Body regarding the Pressure Equipment Directive can be found at www honeywell com A hard copy may be obtained by contacting a Honeywell representative Electro Magnetic Compatibility EMC 2004 108 EC All Models EN 50081 1 1992 EN 50082 2 1995 EN 61326 1 1997 A1 A2 and A3 Industrial Locations Dual Seal Certification based on ANSI NFPA 70 202 and ANSI ISA 12 27 01 requirements without the use of additional seal protection elements Honeywell recommends verifying the calibration of these devices once every four years Honeywell Process Solutions York PA USA Honeywell Tianjin Limited Tianjin P R China Honeywell Automation Ind
27. lly Safe Ex ia IIC T4 T5 T6 Zone 0 1 SAEx Soun Eameproof Zone 1 Ex d iG T5 T6 Enclosure IP 66 67 Afri Multiple Marking nea Intr Safe Zone 0 1 orl Ex ia IIC T4 T5 T6 ZA Flameproof Zone 1 Ex d IIC T5 T6 Enclosure IP 66 67 CERTUSP Flameproof Zone 1 BR Ex d IIC T5 T6 INMETRO Intrinsically Safe BR Ex ia IIC T4 T5 T6 See CERTUSP certificate for Brazil Zone 0 1 detailed temperature codes by Communications option Approvals continued on next page 22 34 ST 16U 01 Issue 66 Page 4 of 5 TABLE Ill Approvals Options continued eee Approval Type Location or Classification Selection Intrinsically Safe Zone 0 x111G Intrinsically Safe Zone 1 Dust tight Enclosure Zone 0 Flameproof and Dust tight Enclosure Zone 1 Non Sparking Zone 2 x I1 3 GD ATEX LCIE 9 111 GD Multiple Marking Int Safe Zone 0 1 and Dust tight Enclosure or Flameproof Zone 1 and Dust tight Enclosure or Non Sparking Zone 2 3 Hastellov C 276 or UNS N10276 4 Manel Ann ar LINS NAAANN ST 3000 Smart Pressure Transmitter STD1xx i ee ial 20 30 70 25 10 Ex ia IIC T4 Ta 50 C to 93 C T5 Ta 50 C to 85 C T6 Ta 50 C to 70 C Enclosure IP 66 67 Ex ia IIC T4 Ta 50 C to 93 C T5 Ta 50 C to 85 C T6 Ta 50 C to 70 C Enclosure IP 66 67 Ex tD A20 IP6X T95 C at Ta 93 C or T80 C at Ta 78 C
28. ne of from the many other on board advanced diagnostic the following output communication options features Honeywell s high performance ST 3000 100 transmitters lead the industry in Communications options 4 20 mA e Accuracy 7 e Stability Honeywell Digitally Enhanced DE e Reliability HART versions 5 x or 6 x e Rangeability FOUNDATION Fieldbus e Warranty ST 3000 Lifetime Transmitter Benefits Total Accuracy 0 0375 Stability 0 01 per year Reliability 470 years MTBF Rangeability 400 to 1 Lifetime Warranty 15 years The devices provide comprehensive self diagnostics to help users maintain high uptime meet regulatory requirements and attain high quality standards S100 transmitters are ideal for critical applications such as custody transfer of natural gas and energy and material balances where accuracy and stability are important Description The ST 3000 transmitter can replace any 4 to 20 mA output transmitter in use today and operates over a standard two wire system The measuring means is a piezoresistive sensor which actually contains three sensors in one It uses a differential pressure sensor a temperature sensor and a static pressure sensor in delivering the most comprehensive compensated output signal available today Microprocessor based electronics provide higher span turndown ratio improved temperature and pressure compensation and improved accuracy The transmitte
29. onnections 316 SS Electronics Housing with M20 to 1 2 NPT 316 SS Conduit Adaptor for use with FM and CSA Approval codes 1 2 NPT Male to M20 Female 316 SS Certified Conduit Adapter ATEX CSA amp IECEx 1 2 NPT Male to 3 4 NPT Female 316 SS Certified Conduit Adapter ATEX CSA amp IECEx M20 Male to 1 2 NPT Female 316 SS Certified Conduit Adaptor ATEX CSA amp IECEx 1 2 NPT Zinc plated Certified Conduit Plug ATEX CSA amp IECEx 1 2 NPT 316 SS Certified Conduit Plug ATEX CSA amp IECEx M20 316 SS Certified Conduit Plug ATEX CSA amp IECEx 1 2 NPT Non certified Conduit plug Zinc plated carbon steel general use NAMUR Failsafe Software SIL 2 TUV Certified transmitter requires HC or H6 and WP options Lightning Protection Custom Calibration and D in Memory Transmitter Configuration non Fieldbus Transmitter Configuration Fieldbus Write Protection Delivered in the enabled position Write Protection Delivered in the disabled position Steel Customer Wired On Tag 4 lines 26 characters per line customer supplied information Stainless Steel Customer Wired On Tag blank High Accuracy Low Temperature 50 C Ambient Limit TUS m zZz o o o o o o Meter Body Options ean 316 SS Bolts and 316 SS Nuts for Process Heads B7M Bolts and Nuts for Process Heads NACE A286 SS Bolts and 304 SS Nuts for Process Heads 316 SS Adapter Flanae 1 2 NPT with CS Bolts 316 SS
30. ptions include 316 SS NACE A286 SS bolts and 304 SS nuts and B7M Optional Adapter Flange and Bolts Adapter Flange materials include 316 SS Hastelloy C 276 and Monel 400 Bolt material for flanges is dependent on process head bolts material chosen Standard adaptor o ring material is glass filled PTFE Viton and graphite are optional Mounting Bracket Carbon Steel Zinc plated or Stainless Steel bracket or Carbon Steel flat bracket available standard options Fill Fluid Silicone DC 200 oil or CTFE Chlorotrifluoroethylene Note that Model STD110 is only available with silicone fill fluid Electronic Housing Epoxy Polyester hybrid paint Low Copper Aluminum Meets NEMA 4X watertight and NEMA 7 explosion proof All stainless steel housing is optional Mounting Can be mounted in virtually any position using the standard mounting bracket Bracket is designed to mount on 2 inch 50 mm vertical or horizontal pipe See Figure 3 Process Connections 1 4 inch NPT 1 2 inch NPT with adapter standard option meets DIN requirements Wiring Dimensions Net Weight Accepts up to 16 AWG 1 5 mm diameter See Figure 4 9 0 pounds 4 1 Kg Vent Drains are sealed with Teflon or PTFE Hastelloy C 276 or UNS N10276 3 Monel 400 or UNS N04400 Supplied as 316 SS or as Grade CF8M the casting equivalent of 316 SS Carbon Steel heads are zinc plated and not recommended for
31. r 0 075 of span For URV below reference point 500 psi effect equals 500 psi 35 bar 0 0125 0 0625 OF 0 0125 0 0625 in of span span psi span bar Combined Zero and Span Static Pressure Effect per 1 000 psi 70 bar 0 15 of span For URV below reference point 500 psi effect equals 500 psi 35 bar 0 0875 0 0625 OF 0 0875 0 0625 in of span span psi span bar Stability 0 03 of URL per year Performance specifications are based on reference conditions of 25 C 77 F zero 0 static pressure 10 to 55 RH and 316 Stainless Steel barrier diaphragm ST 3000 Smart Pressure Transmitter Performance Under Rated Conditions All Models Parameter Description Output two wire Digital communications Analog 4 to 20 mA Normal signal range is 2 3 8 mA and lt 20 8 mA Transmitter failure values are is 2 3 6 mA and lt 20 9 mA Honeywell DE mode FOUNDATION Fieldbus or HART protocol selectable versions 5 x or 6 x available Supply Voltage Effect 0 005 span per volt Damping Time Constant Adjustable from 0 to 32 seconds digital damping NAMUR NE 43 Compliance Option NE Transmitter failure information is generated when the measuring information is invalid or no longer present Failure information is transmitted as a current signal but outside the no
32. r on NPT Head __H Carbon Steel heads are zinc plated and not recommended for water service due to hvdroaen miaration Use 316 wetted process heads instead Vent Drains amp Pluas are sealed with Teflon or PTFE Hastellov C 276 or UNS N10276 Monel 400 or UNS N04400 Supolied as 316 SS or as Grade CF8M the castina eauivalent of 316 SS Supplied as indicated or as Grade CW12MW the castina eauivalent of Hastellov C 276 Sunpolied as indicated or as Grade M30C the castina equivalent of Monel 400 Monel 400 or UNS N04400 or UNS N04405 Materials of Construction ae ee e nee ON DOO FP ON 19 20 ST 3000 Smart Pressure Transmitter 34 ST 16U 01 Issue 66 Availability Page 2 of 5 STD1xx EELE TABLE Il Selection 20 30 70 25 10 No Selection 00000 ojo ojoj o TABLE Ill OPTIONS Selection Communication Options Must choose a communications option ea a Sees ip ian eT Analog only can be configured using appropriate Honeywell DE tool DE Protocol communications HART 6 x Protocol compatible electronics TM iene Analog Meter 0 100 Even 0 10 Square Root Smart Meter Custom Configuration of Smart Meter Local Zero amp Span Local Zero No housing conduit plugs or adaptors come standard with the ST 3000 For certain approval codes you must select a certified conduit plug from below and it will come packaged in the box with your transmitter 316 SS Electronics Housing with M20 Conduit C
33. rmal 4 20 mA measurement signal level Transmitter failure values are lt 3 6 mA and 2 21 0 mA The normal signal range is 2 3 8 mA and lt 20 5 mA SIL 2 3 Compliance Option SL SIL certified to IEC 61508 for non redundant use in SIL 2 related Safety Systems single use and for redundant multiple use in SIL 3 Safety Systems through TUV Nord Sys Tec GmbH amp Co KG under the following standards IEC61508 1 1998 IEC 61508 2 2000 IEC61508 3 1998 Lightning Protection Option Option LP Leakage Current 10 microamps max 42 4 VDC 93 C 10 20 yu sec 5 000 Amps 50 strikes 10 1 000 usec 250 Amps 1 000 strikes Impulse Rating rise decay 10 000 Amps 20 strikes 500 Amps 400 strikes Physical and Approval Bodies Parameter Description Barrier Diaphragms Material STD125 STD110 STD120 STD130 STD170 316L SS Gold plated 316L SS 316L SS Hastelloy C 2767 Monel 400 Tantalum Gold plated 316L SS Gold plated Hastelloy C 276 Gold plated Monel 400 Process Head Material STD125 STD110 STD120 STD130 STD170 Vent Drain Valves amp Plugs 1 316 SS Carbon Steel Zinc plated 316 SS Carbon Steel Zinc plated Hastelloy C 276 Monel 400 316 SS Hastelloy C 276 Monel 400 Head Gaskets Glass filled PTFE standard Viton and graphite are optional See MSG Meter Body Bolting Carbon Steel Zinc plated standard O
34. rs meter body and electronics housing resist shock vibration corrosion and moisture The electronics housing contains a compartment for the single board electronics which is isolated from an integral junction box The single board electronics is replaceable and interchangeable with any other ST 3000 Series 100 or Series 900 model transmitters Advanced Diagnostics ST 3000 is now available for both HART 6 and Foundation Fieldbus with advanced diagnostics that minimize unplanned plant outages minimize maintenance costs and by providing the industry s most reliable transmitter e Provide advanced warning of possible failure events and avoid costly shutdowns e Three levels of failure reporting e Comprehensive list of on board diagnostics Ref ST 3000 User manual with HART 6 34 ST 25 17 Rev June 09 and Foundation Fieldbus option manual 34 ST 25 15 Rev June 09 ST 3000 Smart Pressure Transmitter Configuration Tools Like other Honeywell transmitters the ST 3000 features two way communication and configuration capability between the operator and the transmitter through several Honeywell field rated portable configuration devices including the Smartline Configuration Toolkit and the Multiple Communication Configurator MC ToolKit While both are made for in field use the MC Toolkit also can be ordered for use in intrinsically safe Class I Div 1 environments The SCT 3000 Smartline Configuration Toolkit pro
35. s many Table III options as desired plus a communications option selection A denotes unrestricted availability A letter denotes restricted availability Restrictions follow Table IV l ll lll Optional IV ___ ooo00 gt xxxx KEY NUMBER SA Selection Availability 0 1 to 0 400 biog I 0 2 5 ie 0 1 000 mbar STD120 Body Rating 4 500 psi 315 bar 0 1 to 0 100 psi 0 0 07 to 0 7 bar TD1 Body Rating 4 500 psi 315 bar E EINE 0 30 to 0 3 000 psi 0 2 1 to 0 210 bar STD170 Body Rating 4 500 psi 315 bar osvo iv 0 6 to 0 600 WO 10 15 to 0 1 500 mbar STD125 Body Rating 4 500 psi 315 bar 0 0 4 to 0 10 H O 0 1 to 0 25 mbar STD110 Vv Body Rating 50 psi 3 5 bar Compound Characterized Base STD models no longer include a default communications option All units now require the selection of a communication option from Table IlI AN DE HC H6 or FF Important Note TABLE METER BODY Vent Drain ioe and ugs Carbon Steel 316L SS Carbon Steel Hastelloy C 276 Carbon Steel Monel 400 O Tantalum 316L SS Hastelloy C 276 Monel 400 Sanu 316 SS ae ef Hastelloy C 276 Hastelloy C 276 ee ee eel Hastelloy C 276 gt _Hastelloy C 276 Tantalum Mone 499 Monel 4gg monergoo t f to peee tJ DC 200 Silicone le CTFE _ _ Process Head Ya NPT __A Configuration Y2 NPT with Adapte
36. ssure Limit Maximum Allowable Working Pressure MAWP Overpressure Limit for ST 3000 Differential Pressure Transmitters 1 For CTFE fill fluid the rating is 15 to 110 C 5 to 230 F Short term equals 2 hours at 70 C 158 F MAWP applies for temperature range 40 to 125 C However Static Pressure Limit is de rated to 3 000 psi from 26 C to 40 C Use of graphite o rings de rates transmitter to 3 625 psi Consult factory for MAWP of ST 3000 transmitters with CSA approval Loop Resistance ohms 800 650 450 250 0 10 8 16 28 20 63 25 28 3 37 0 Operating Voltage Vdc Use of adaptor with graphite o rings de rates transmitter to 3 000 psi Note A minimum of 250 ohms of loop resistance is necessary to support communications Loop resistance equals barrier resistance plus wire resistance plus receiver resistance A Operating Area Figure 2 Supply voltage and loop resistance chart 42 4 ST 3000 Smart Pressure Transmitter Performance Under Rated Conditions Model STD110 0 to 10 inH O Parameter Description Upper Range Limit inH O 10 39 2 F 4 C is standard reference temperature for inH O range mbar 25 Minimum Span inH O 0 4 mbar 1 Turndown Ratio 25 to 1 Zero Elevation and Suppression No limit except minimum span within 100 URL Accuracy Reference Includes combined effects of linearity hysteresis and repeatability e Acc
37. teel or stainless steel and is suitable for horizontal or vertical mounting on a two inch 50 millimeter pipe as well as wall mounting An optional flat mounting bracket is also available in carbon steel for two inch 50 millimeter pipe mounting An option also exists for Marine approved mounting brackets used with Marine certification options Indicating Meter Options ME and SM Two integral meter options are available An analog meter option ME is available with a dual O to 10 square root and 0 to 100 linear scale The Smart Meter option SM provides an LCD display for both analog and digital output and can be configured to display pressure in selected engineering units HART Output Protocol Options HC and H6 Optional electronic modules for the ST 3000 provide HART Protocol compatibility in either HART 5 x or 6 x formats Transmitters with a HART Option are compatible with any HART enabled system that provides 5 x or 6 x format support Digital Enhanced Output Option DE A communications protocol used together with TDC and Experion system solutions to provide a higher level and more secure data interface between instruments and the control system Foundation Fieldbus Output Option FF Equips transmitter with FF protocol for use in 31 25 kbit s FF networks See document 34 ST 03 72 for additional information on ST 3000 Fieldbus transmitters SIL2 SIL3 Certification Option SL This ST 3000 product is available for use wit
38. traction damping time LRV URV and mode analog digital and enter an ID tag of up to eight characters and scratchpad information as specified With Option FC the Device ID Transmitter Tag Unit Level Node Address Output Mode and Damping Time Constants can be specified Custom Calibration and ID in Memory Option CC The factory can calibrate any range within the scope of the transmitter s range and enter an ID tag of up to eight characters in the transmitters memory Indicator Configuration Option Cl Provides custom configuration of Smart Meters Lifetime Warranty Option WL Extends limited 1 year warranty policy to 15 years for ST 3000 S100 pressure transmitters See Honeywell Terms and Conditions 36 ST 3000 Smart Pressure Transmitter Model Selection Guides are subject to change and are inserted into the specifications as guidance only Prior to specifying or ordering a model check for the latest revision Model Selection Guides which are published at http hnosweb honeywell com Cultures en US Products Instrumentation ProductModelSelectionGuides default htm Model Selection Guide ST 3000 Smart Transmitter gt _ gt Differential Pressure DP Series 100 34 ST 16U 01 Issue 66 Page 1 of 5 Model Selection Guide Instructions Select the desired Key Number The arrow to the right marks the selection available Make one selection from each Table I II and IV using the column below the proper arrow Select a
39. uracy includes residual error after averaging successive readings For FOUNDATION Fieldbus use Digital Mode specifications For HART use Analog Mode specifications In Analog Mode 0 1 of calibrated span or upper range value URV whichever is greater terminal based For URV below reference point 1 5 inH O accuracy equals 1 5 inH O 3 75 mbar l 0 025 0 075 or t 0 025 0 075 _ in of span span inH O span mbar In Digital Mode 0 0875 of calibrated span or upper range value URV whichever is greater terminal based For URV below reference point 1 5 inH O accuracy equals 1 5 inH O 3 75 mbar l or 0 0125 0 075 in of span 0 0125 0 075 span inH O span mbar Zero Temperature Effect per 28 C 50 F Combined Zero and Span Temperature Effect per 28 C 50 F In Analog Mode 0 2625 of span For URV below reference point 10 inH O effect equals 10 inH O 25 mbar 0 0125 0 25 or 0 0125 0 25 in of span span inH O span mbar In Digital Mode 0 25 of span For URV below reference point 10 inH O effect equals 10 inH O 25 mbar 0 25 or 0 25 in of span span inH O span mbar In Analog Mode 0 4875 of span For URV below reference point 10
40. vides an easy way to configure instruments using a personal computer as the configuration interface The toolkit enables configuration of devices before shipping or prior to field installation The SCT 3000 can operate in the off line mode to pre configure an unlimited number of devices This database can then be loaded down line during instrument commissioning Features e Choice of linear or square root output conformity is a simple configuration selection e Direct digital integration with Experion PKS and other control systems provides local measurement accuracy to the system level without adding typical A D and D A converter inaccuracies e Unique piezoresistive sensor automatically compensates input for real world temperature and static pressure variations e Added smart features include configuring lower and upper range values simulating accurate analog output and selecting preprogrammed engineering units for display e Smart transmitter capabilities with local or remote interfacing means significant manpower efficiency improvements in commissioning start up and ongoing maintenance functions e ST 3000 transmitters feature full Dual Seal certification based on ANSI NFPA 70 202 and ANSI ISA 12 27 01 requirements without the use of additional seal protection elements e ST 3000 transmitters are available fully compliant to SIL 2 3 requirements as a standard option ST 3000 Smart Pressure Transmitter Operating