        USER MANUAL - LifeTec Inc.
         Contents
1.     Huntleigh    A K R O N       AKRON    M6M    Model  8462    USER MANUAL    AKRON 8462    Contents    1     10     Introduction  Warnings  Cautions  General Warnings    Installation    Operation    Accessories     Operating Instructions  Cyriax Horns   Hole  amp  Horn   Lean Back Frame   Fixation Rails    Cleaning and Decontamination  Troubleshooting  Maintenance    Warranty and Service    Revision Status    Technical Specification    C        The C     mark on this product demonstrates conformity    with the EC Directive 93 42 EEC      NO    ON UN da    III aq    10  11    11    12    AKRON 8462  1  Introduction    Always keep this Operating Manual available for reference     Warnings  amp  Cautions    WARNINGS  Warnings identify possible hazards in procedures or conditions which  if not correctly followed   could result in death  injury or other serious adverse reactions     CAUTIONS  Cautions identify conditions or procedures which  if not correctly followed  could result in equipment  failure or damage        General Warnings    WARNINGS  Use only accessories that have been designed or approved for use with this couch     Do not use electric couches in the presence of flammable gasses such as an  anaesthetic agent     Maximum Load 180  396 Ibs  distributed evenly   Do not concentrate weight on either side of the couch   Plug acts as a disconnect device     Do not allow children to play with the couch at any time     Adequately supervise children in the proximity of the
2.    Press out from underneath        AKRON 8462    4  Accessories     Operating Instructions    Cyriax Horns    Fixation Rails          Adjust Cyriax Horns to suit patient by     A  Unlocking the locking knobs   B  Adjust position of horns     C  Tighten locking knobs     To fit Horn into Hole     A  simply locate horn into hole     B  Ensure horn is fully inserted prior to use     To adjust Lean Back Frame     A  Remove locating pins from frame   B  Slide frame to required position     C  Replace pins into holes at the end of the frame     Ensure straps are correctly located through fixation rails before use     AKRON 8462    5  Cleaning and Decontamination    WARNING  Do not use Alkalis or other organic solvents for routine cleaning     Replace torn or damaged vinyl immediately     Always cover vinyl with fresh paper or sheet between patients     If contamination is known or suspected always decontaminate couch before use        Frequency of routine couch cleaning will depend on exact application   CLEANING   DECONTAMINATION    Wear suitable protective clothing  Disconnect mains supply  Locate couch in a suitable cleaning area with castors disengaged or wheels locked     A  Using a clean damp cloth  warm water and soap carefully wipe couch from top to bottom  taking  care around electrical components    B  Wipe couch carefully from top to bottom using a damp cloth and clean water    C  Wipe couch carefully dry with clean paper towels from top to bottom     If DECONTAMINATING
3.  couch        AKRON 8462    2  Installation    Adjustable Foot    WARNING    Lock castors before adjusting        A  Lock castors first   B  Adjust foot     C  Lock foot by tightening half nut        WARNING  Do not insert the 2 pin mains connector directly into a 3 pin 13A mains outlet   Always use the adapter provided    Plug acts as a disconnect device        Electric Models    Use adapter if 3 pin 13A plug is required    Order reference 5504097        Ensure mains supply cable is not stretched when connected   Ensure  during couch use  no obstacles are in its path     Ensure hand   foot switch tubes or leads are not trapped by moving parts of the couch     CAUTION    When not in use  switch couch off        AKRON 8462    3  Operation    Elevation Controls    WARNING  Safely position patient before elevating couch     Position all electrical cables away from the moving parts   Position Hand Foot switch where accidental operation is not possible        Electric Models    Press   to raise couch     Press Y to lower couch        Handswitch    AUF  Press   to raise couch    AB  Press to lower couch        Footswitch    Foot Bar Switch    Press tube done to raise couch    Lift tube up to lower couch       AKRON 8462    3  Operation    Wheel Locking    WARNING  Lock couch wheels castors prior to patient transfer or treatment     The retractable castors are not designed for transportation of patients   Disconnect and coil electrical cord away from moving parts prior to  repositio
4.  then repeat steps a  to c  using a dilute Hypochlorite   warm water mixture   10 000ppm  instead of warm water and soap    Safely discard cleaning   decontaminating materials    Wash hands thoroughly    Put couch back into service     6  Troubleshooting     Electric Actuator    Symptom    Actuator will not work   Power disconnected Ensure mains supply is connected    Fuse blown Replace fuse in socket    Hand footswitch Check that the hand foot switch is fully  disconnected inserted into the actuator    Actuator runs when Bar   Out of balance system Vent air tube by disconnecting from  is not pressed actuator  then reconnect   Foot Bar Switch        If the problem persists consult your local Akron Supplier     AKRON 8462  7  Maintenance    Check couch visually before use   Carry out routine servicing every six months or more frequently if in heavy use     Routine servicing or repair must only be performed by suitably qualified person     WARNING  Before commencing any maintenance activity  disconnect the couch from the    electrical supply   Plug acts as disconnect device        Examine the couch for any signs of damage  Make sure that all nuts  bolts and other fasteners are tight   Do not over tighten as this may cause binding     Upholstery fasteners should be checked  tightened or replaced if necessary   Check section hinge pins to ensure that no pin protrudes   Check gas strut controls  throughout the full range of movement for locking and assistance     Check hydraulic c
5. he decontamination certificate  or other written statement declaring that the product has  been cleaned  to the outside of the package    4  Mark the package    Service Department        Manufactured in the UK by Huntleigh Akron  As part of the ongoing development programme this  company reserves the right to modify specifications and materials of this couch without notice     10    AKRON 8462    8  Warranty and Service  UK only     Huntleigh Akron s standard terms and conditions apply to this couch  A copy is available upon request   These contain full details of warranty terms and do not limit the statutory rights of the consumer     For service  maintenance and any questions regarding this  or any other Huntleigh Akron Product  please    contact     Huntleigh Akron   I Farthing Road   Ipswich   Sutfolk   IP  SAP    England   Telephone   44  0  1473 461042  Fax   44  0  1473 462924    Huntleigh Akron T A a Division of Huntleigh Nesbit Evans Limited  A Member of the Huntleigh Technology PLC Group of Companies  O Huntleigh Technology PLC 2001     If for any reason your couch is being returned  please inform Huntleigh Akron prior to sending and     l   3     4     Clean the product  as described in the cleaning section    Pack it 1n suitable packing    Attach the decontamination certificate  or other written statement declaring that the product has been  cleaned  to the outside of the package    Mark the package  Service Department        Manufactured in the UK by Huntleigh Ak
6. ning couch        Castors       Castors Unlocked Castors Locked    Head  amp  Foot Sections    CAUTION    Support upholstery section while manually altering the angle        Head Section Operating Lever       A  Press lever UP to alter section angle    B  Support section when altering angle    C  Release lever to lock section in position   A  Tilt armrest towards head section    B  Move armrest into position    C  Release armrest to lock into position     AKRON 8462    3  Operation    Foot Section    CAUTION    The foot section 1s able to move in two independent modes     It is recommended that Operators familiarise themselves with the functions of each mode  prior to  using the couch with a patient        Flexion  amp  Extension To adjust the foot section for flexion  amp  extension       A  Rotate the lever positioned under the foot section  clockwise or  anti clockwise     B  Raise or lower section to desired angle     C  To secure foot section at correct angle  continue to rotate the lever        Foot Section Angles   4 26   25      Foot Section Operating Lever    Side Bending    To release the foot section to enable side bending       A  Rotate the lever under the mid section upholstery anti clockwise   B  Rotate the foot section to desired position   C  Rotate the lever clockwise to secure foot section in desired position        Angles   30 35    along the horizontal axis   Side Bending Release Lever    Breathing Hole and Plug    Remove plug for patient prone position  
7. ouches for smooth operation and signs of leakage     WARNING  All electrical checks should be performed by a suitably qualified and licensed  electrician     Neither BLUE or BROWN wires are to be connected to the earth terminal of a  three pin plug        Examine the flexible cables for cuts  abrasions  kinking or other deterioration and replace if necessary   Ensure that the power supply connector plug 1s securely attached     Check mains plug connections are tight and fuse is correctly rated  SA      AKRON 8462  8  Warranty and Service  UK only     Huntleigh Akron s standard terms and conditions apply to this couch  A copy 1s available upon request   These contain full details of warranty terms and do not limit the statutory rights of the consumer     For service or maintenance please contact     Service Department    Huntleigh Healthcare   310 312 Dallow Road   Luton   Beds Telephone  01582 745700  LUI 1TD Fax  01582 745869    For information on this product  or any other Huntleigh Akron product  please contact     Huntleigh Akron    Farthing Road  Ipswich Telephone  01473 461042  IP  SAP Fax  01473 462924    Huntleigh Akron T A a Division of Huntleigh Nesbit Evans Limited  A Member of the Huntleigh Technology PLC Group of Companies  O Huntleigh Technology PLC 2001     If for any reason your couch is being returned  please inform Huntleigh Akron prior to sending  and     l  Clean the product  as described in the cleaning section   Pack it in suitable packing    3  Attach t
8. ron  As part of the ongoing development programme this  company reserves the right to modify specifications and materials of this couch without notice     9  Revision Status    8462  PAGES ISSUE WRITTEN DATE  ALL PAGES UM   01 08 06 98    ALL PAGES UM   02 02 12 98  PAGES 10  amp  11 UM   03 18 11 99       PAGE 2 UM   04  DCN958  30 10 00    11    AKRON 8462    10  Technical Specification    Akron M6M    Le  Head length  cm   Mid Length  cm   Foot Length  cm   Width  cm   Overall Length  cm   Height Range  cm  62 1 5  109 1 5  Max  Load Weight  Elevation Control  AA    Electrical Data 230v    Actuator  Internal Fuse Rt  Current  Power  Mains Plug Fuse Rt  UK   ee WW    Actuator    Internal Fuse Rt F4 0A x 1  Current  Power 380W       IEC 601 1 Classification  Check serial number label for classification    230v 115y 115y    E Double Insulated E Double Insulated Class 1    Type B equipment    Type B equipment    2      Type B equipment    2         Attention consult this    Attention consult this    Attention consult this  manual manual manual    12       pum w  Huntleigh    A K RON    Huntleigh Akron  1 Farthing Road  Ipswich  Suffolk  IP1 SAP  England  Tel   44  0  1473 461042 Fax   44  0  1473 462924    792 187 04    
    