Home
        DOCU-M0143_30100_AG-MAC PLUS English_French.indd
         Contents
1.   RECORD SERIAL NUMBER    NOTE  The tester serial number is located on the bottom of the unit     Write your model number  serial number and date of purchase in the space  provided below  Agratronix needs this information when ordering parts and when  filing warranty claims     Model    Serial No     Date of Purchase   To be filled in by purchaser        21    Replacement Parts    ACCESSORIES      Grain Hopper     Part No  PLAS H0300     Battery Door     Part No  PLAS D0300     USB Port Cover     Part No  PLAS USBP    USB Cable     Part No  06067     Carrying Case     Part No  06080       22    Manufacturer s Contact Information         o o ooo eooo o o  eo o    o    6 6 6 0 6 6 6 6 6 6 o    o    6 6 6 6 6 6 6 6 6 6 6 6 6 o    Toll Free 1 800 821 9542  330 562 2222  FAX 330 562 7403  Wwww Agra Ironix com    10375 State Route 43  Streetsboro  OH 44241  USA       23    
2.  Tester  if weight test readings are not within tolerance    1  Turn on Unit  press ON OFF button    2  Use UP DOWN buttons to scroll to  SETTINGS  then press ENTER   3  Use UP OWN buttons to scroll to    Weight test     Figure 7  then press ENTER   4    Place test weight or 10 new quarters into the test cell when the screen  indicates to    PLACE WEIGHT  Once the weight or quarters are placed   in unit  wait for reading to display  The asterisk in the upper right hand corner  indicates the tester is steady and the weight is then accurate  Figure 8      NOTE  Tolerance is     0 1 for the number of quarters     9 9 or 10 1 is within  tolerance for 10 quarters  Please use 10 new quarters for your check if there is  not a test weight available     Weight test     gt     Figure 7  Weight Test    Asterisk        Indicates  Tester is    Steady Number of  quarters       0 1    Figure 8  Weight Test Reading tolerance     for 10 Quarters       10    Operation    SELECT A DIFFERENT LANGUAGE   1  Turn on Unit  press ON OFF button    2  Use UP DOWN buttons to scroll to  SETTINGS  then press ENTER   3  Use UP OWN buttons to scroll to    Language     Figure 9  then press ENTER  4    Use UP DOWN buttons to scroll to desired language and press enter to  select and save this language  or Press Back Arrow to abort and not select  a new language     Press Back Arrow to return to the active grain display where you are ready  to test    NOTE  For English only versions  English will be the only di
3.  This surface should not be vibrating  it can be  but the more stable  the  more accurate the test weight measurement      c  There should not be a fan blowing directly on the test cell    NOTE  If the unit was not stable during the measurement process  a warning  will appear before the measurements are displayed  It is recommended the  tester be on a flat  non vibrating surface for the readings to be accurate     Any of these conditions will result in the grain test weight taking a longer time to  measure and not being as accurate as it can be if these conditions are all met   The entire test cell is sitting on a precision weigh scale mechanism     that s why  its important to keep it stable  and not to drop the unit or damage may occur      FOR BEST GRAIN MOISTURE RESULTS      a  The closer the grain and test cell temperature are to each other  the better  the results     b  The tester compensates for temperature but the grain and test cell  temperature should be within 40 F of each other for best results      c  Use the average feature and always average 3 consecutive tests from the  same grain batch  Grains  such as corn  that have a unigue geometry  can  sit in the test cell slightly differently each time and add some variance in  your results  so averaging 3 readings will give best results     NOTE  Though you can hold the unit in your hand for testing  that is not  recommended since its hard to keep your hand stable and level for the grain  test weight measurement     
4.  to  make changes at any time without notice        Components    COMPONENTS    PART NO  DESCRIPTION   PLAS H0300 GRAIN HOPPER   PLAS D0300 BATTERY DOOR   PLAS USBP USB PORT COVER   06067 USB CABLE   06080 CARRYING CASE      Indicates manufacturer s part numbers        Operation    OPERATING CONDITIONS    Test cell and grain MUST be free of any condensation or surface moisture   Moisture on grain or in test cell will cause high readings  Very hot or cool grain  can pick up moisture when it warms or cools     Because grains are irregularly shaped and may not always pack the same way  in the test cell  minor variations in readings may occur  To enhance accuracy   always take three  3  successive readings and average the results  See page  8 for Average Moisture Measurement Functions   Empty and refill the tester  with new grain from the sample for test  This unit will automatically average the  3 most recent test results  It is important when emptying the tester to make  sure there is no grain lodged in the cell top ring  See page 16 for Troubleshoot     ing     The tester is most accurate when grain and tester are between 60  F  16  C   and 90  F  32  C   The unit will  however  operate at temperatures between  33  F  1  C  and 120  F  49  C   For best results  grain temperature should not be  below 40  F  4  C  or above 110  F  43  C   If the grain temperature is 40  F more  or less than the temperature of the unit  preheat the tester per instructions on  page 05 3  Condensat
5. GRAINS LOW LIMIT HIGH LIMIT  Barley 2R 4  26   Barley 6R 4  26   Corn 6  28   Millet 3  22   Oats 5  25   Rapeseed  Canola  3  20   Rye 5  26   Safflower 3  20   Sorghum  Milo  1  24   Soybeans 4  26   Sunflower Oil 3  22   Triticale 6  20   Wheat  Durum 4  21   Wheat  Hard Red Spring 5  24   Wheat  Hard Red Winter 4  23   Wheat  Soft Red Winter 4  22     NOTE  If grain temperature is 40  F  4  C  or below  or 110  F  43  C  or above   and the grain moisture is near either the high or the low limit of the tester   listed above   the tester may reduce its operating limits  That is  if the grain  temperature is 35F  and rye grain lower limit is 7  moisture  then the adjusted  lower limit may now be 8 5  moisture due to the cold grain temperature     DISCLAIMER  The above moisture limits are approximate values and may  vary  Specifications and design are subject to change without notice     Grain scales will be periodically updated with new grains and limits  New grain  scales and software can be downloaded from www AgraTronix com when the  unit is connected to the internet via a computer and USB cord        Operation    OPERATING PROCEDURE     PREHEATING  IMPORTANT  If the temperature of the grain sample is 40  F more or less than  the temperature of the unit  preheat the tester for best results    as follows     PREHEATING PROCEDURE    1  Press and release ON OFF button  B  to turn on tester  The display  C  will  show the name of the last grain tested at the top  Secure hoppe
6. NOTE  Store your tester inside your house when not in use  Always store and  transport your instrument in the provided carry case  Remove batteries when  not in use        Operation    AVERAGE MOISTURE MEASUREMENT FUNCTIONS   There are two    average    functions in your tester    FUNCTION 1 is AVG num     This means the    number    of Averages  AVG   That  is  you can program your tester to automatically average up to 3  6  or 9 consecu   tive moisture measurements and display the result  The majority of users will not  adjust the default averaging mode of averaging every 3 consecutive moisture  measurements  We added averaging 6 or 9 readings for users who are using the  tester in unique applications     FUNCTION 2 is Clear AVG        Clear average    will clear the current average  moisture results  Let s say you just took moisture measurements in one grain bin   but you are now done with that grain bin  Next you go to another grain bin to test  another batch of grain  You can clear the previous average and start fresh with the  averages for your next grain bin     Now Let s discuss how to use and select each of the two AVG  Average  moisture  measurement functions     FUNCTION 1     AVG num  number of consecutive moisture measurements  to average  see Figure 4      1  Turn on Unit  press ON OFF button   Use Up Down buttons to scroll to    SETTINGS    then press ENTER  Use UP DOWN Buttons to scroll to  AVG num     Press ENTER until your desired number to average is displa
7. Operators Manual    AG MAC  PLUS    Grain Moisture Tester          DOCU M0143 0813    Operators Manual    AG MAC  PLUS    Grain Moisture Tester       ENGLISH  DOCU M0143 0813    Introduction    THANK YOU for purchasing an Agratronix grain moisture tester      Please treat your instrument with care  Misuse such as tossing or  dropping the unit can potentially damage the weigh scale mechanism  or other parts of this device        READ THIS MANUAL carefully to learn how to operate this unit correctly  Failure  to do so could result in personal injury or equipment damage     THIS MANUAL SHOULD BE CONSIDERED a permanent part of this tester and  should remain with the unit when you sell it     RECORD SERIAL NUMBERS in the warranty section located on page 21  accurately record all the numbers  Your dealer needs these numbers when  you need service or parts  If this manual is kept with the equipment  also file  the serial numbers in a secure place away from the unit     WARRANTY is provided through Agratronix for customers who operate and  maintain their equipment as described in this manual  The warranty is explained  in the warranty section located on page 21     This warranty provides you the assurance that Agratronix will back its prod   ucts where defects appear within the warranty period  In some circumstances   Agratronix provides field improvements  often without charge to the customer   even if the product is out of warranty  Should the equipment be abused or  modified to ch
8. ange specifications  the warranty will become void and field  improvements may be denied     If you do not understand any part of this manual and need assistance  contact  Agratronix Customer Service at 1 800 821 9542     All information  illustrations and specifications in this manual are based on the  latest information available at the time of publication  The right is reserved to  make changes at any time without notice     Please visit us at www AgraTronix com to view this manual along with the  complete line of Agratronix products        Operation    Operation   Components   Operating Conditions   Operational Messages   Moisture Limit Guidelines   Operating Procedure     Preheating  Operating Procedure     Normal Operation  Average Moisture Measurement Functions  Select a Different Grain   Weight Test     Test Weight Accuracy  Select a Different Language   Adjust Grain Offset  bias calibration   Clear Grain Offset   Turn Backlight On or Off   Temperature and Test Weight Units   Auto Off Setting   LCD Contrast   Personalizing and Updating the Tester    Troubleshooting    Service   Check Battery Power Levels and Replace Batteries   Clean the Tester     Test Cell 17  Clean the Tester     Top Ring 19  Error Codes 20    Warranty 21    Record Serial Numbers 21  Accessories 22  Manufacturer s Contact Information 23    All information  illustrations and specifications in this manual are based on the  latest information available at the time of publication  The right is reserved
9. buttons to scroll to    SETTINGS    then press ENTER    2    3  Use UP DOWN buttons to scroll to    Auto off     Figure 14    4  Press    ENTER    to scroll through the choices  30 seconds  1 minute  5 min    10 min   or 20 min   and once the desired option is displayed  Press Back arrow to save it  You are now back to the active grain display  where you are ready to test     Auto off        Figure 14  Auto Off       14    Operation    LCD CONTRAST    You will likely not need to adjust the LCD contrast since the default setting will  meet the needs of most people  Be careful if you do adjust your LCD contrast  since you may get to either extreme  too high or too low  where you can no longer  see text on your display       Turn on Unit  press ON OFF button   Use UP DOWN buttons to scroll to    SETTINGS    then press ENTER  Use UP DOWN buttons to scroll to    Contrast     Figure 15   Press ENTER  Press UP DOWN buttons until desired LCD contrast is achieved    Press ENTER to save new contrast  or press Back Arrow if you don t want  to save this new contrast level     Press Back arrow to return to the active grain display where you are ready  to test    Figure 15  Contrast Screen    PERSONALIZING AND UPDATING THE TESTER    1  The tester is equipped with a USB port and when connected to the internet  via a computer will allow for diagnostics and updates to its software and  grain calibrations       Visit www AgraTronix com to use your USB port for personalization  adding  user nam
10. cure battery door  A      A     Battery Door    B     Batteries   4 AA alkaline batteries     Figure 18  Removing Battery Door    CLEANING THE TESTER     TEST CELL    Use a soft  clean cloth to wipe out the cell  using extreme care not to damage  the grain temperature sensor at the bottom of the test cell     Grain Temperature Sensor    Figure 19  Grain Temperature Sensor       18    Service    CLEANING THE TESTER     REMOVAL OF TOP RING    NOTE  It is important when emptying the tester to make sure there is no grain  lodged in the cell top ring     If test weight readings appear to be inaccurate  use the following steps to  remove the top ring and clean out excess grain and or debris     REMOVING AND CLEANING TOP RING    Use a soft  clean cloth to wipe out the cell  using extreme care not to  damage the grain temperature sensor at the bottom of the test cell     Use a pointed object to pop out one of the tabs of the top ring on the inside  of the cell     Remove ring       Turn tester upside down and gently shake back and forth to remove any  grain   debris that may have entered the tester       Check the inside of the ring before reattaching     PLACING TOP RING BACK ON UNIT  1  Align the tabs and push down     2  Lightly grab the ring and attempt to turn it     making sure the tabs are  locked into place     NOTE  Listen for the tabs to lock into place     Top Ring Tab    Figure 20  Top Ring Tab       19    Service    IN ERROR CODES     As with most test instruments there 
11. e   grain scale  firmware and diagnostic updates        15    Troubleshooting    Symptom A  Unit does not power up or loses power occasionally   Solution 1  Press ON OFF button for shorter time  Do NOT hold button down   Solution 2  Check batteries for 0  or higher  Replace as necessary   Solution 3  Confirm all four batteries are properly oriented     Symptom B  Unit is inaccurate    Solution 1  Temperature of the grain and unit may be more than 40 F different   Follow preheat procedure  See page 4     Solution 2  If grain is at an extreme temperature  let grain settle to reach room  temperature     Retest grain    Solution 3  Grain and or test cell may have developed surface moisture from  rapid change in temperature of the grain sample  Allow grain and tester to stabi   lize near room temperature    Inspect for visible moisture on grain and inside test cell  Dry the test cell with a  soft cloth or a blow dryer if necessary  Retest grain    Solution 4  If the tester displays BATTERY LOW  the test results may be inaccu   rate  Replace battery    Solution 5  Check for lodged grain under cell top ring and use weight test under  settings menu  see page 10   Grains that are smaller in nature or carry debris are  more likely to get lodged  For cleaning instructions  see page 18     Solution 6  Unit may need to be recalibrated by factory  Return tester to your  Agratronix dealer for repair or replacement or call Agratronix customer service at  1 800 821 9542     Symptom C  Unit sh
12. e pour hole  Pull level arm      towards the display and lift up on Hop  per  G  to remove it  Figure 3    Place  it to the side in a safe place where it  won t be dropped     Level Grain     When prompted  push   grain level arm  I  in a slow steady   motion towards the back of the unit to   push excess grain out of the test cell    For some grains you may not be able to   initially do this with in one motion    and if so then pull the level arm     half   way back and push again toward the Figure 3  Pull level arm forward   back of the test cell to level the grain  Lift hopper up    Pull level arm back towards the   display  Look at the level arm brush and   ensure it is not touching the test cell   or the grain test weight will be affected  Once level arm returns  toward the  display  take hands off the tester  if it s sitting on a flat surface  and it will  automatically start measuring  Remove hands and keep stable since test  weight is the first part of the measurement     Done      The measurement results  test weight  grain temperature and  average test results are now displayed     NOTE  Don t swipe grain too fast with grain level arm     A    Test Cell   B     ON OFF Button   C     Display   D UP  DOWN Arrows   E     BACK Arrow   F     ENTER   TEST Button  G     Grain Hopper   H     Grain Hopper Slider         Level Arm with Brush       Operation    FOR BEST GRAIN TEST WEIGHT RESULTS    a  Sit tester on a semi level  flat surface with an angle of less than 5      b 
13. ing  see page 16 for Troubleshooting      SECURING THE HOPPER  1  Place the back hopper tab into the center of the base  Figure 2a      2  Pulllevel arm forward  Figure 2b  and the hopper will lock into place once  the level arm is released     Back Hopper  Tab    Figure 2a  Tab Placement of Hopper Figure 2b  Pull level arm forward    OPERATING PROCEDURE     NORMAL OPERATION    1  Place Hopper on Tester     Secure empty grain hopper  G  to the top of your  tester  Press and release ON OFF button  B  to turn on tester  The top of the  display  C  will show the name of the last selected or tested grain  If this  grain has never been tested then the values that show the last test will be  empty  At power up the display shows the results of the last grain tested       Select Grain     If the desired grain is not shown at the top of the display  C   then use the UP DOWN arrows  D  to choose grain  Once the desired grain  is selected then press and release the ENTER  F  button to make it your  active grain  Place tester on a stable and mostly level surface  Press ENTER  to initiate test       Fill Hopper     Fill hopper to the rim with grain to be tested   ensure hopper  Slider  H  is pushed in to keep grain from dropping early       When prompted  Pour     Pull the hopper slider  H   This will evenly drop grain  into the test cell  A         Operation    5  When prompted  remove Grain Hopper   G      Once test cell is full  then push  the hopper slider  H  back in to close off  th
14. ion on the grain or test cell is best avoided by having the  tester and grain at similar temperatures     The environment to which a grain sample is exposed can appreciably change    its moisture content  Exposed to the open air  grain can gain or lose 1  to 2   indicated moisture in only a few minutes  If a sample is to be held for even a  short time before being tested it should be placed into a tightly closed  air tight  container  such as a re closable bag or airtight plastic container     OPERATIONAL MESSAGES  Symbol Definition    BATTERY LOW Battery needs replacing     lt 4 0 Moisture is below the lower limit for this grain   4  is lower limit for selected grain      gt 28 0 Moisture is above the upper limit for this grain  in  this case 28 0  is the upper moisture limit for  the selected grain     Error code  refer to error code section on page  20 in the manual        Operation    CAUTION  Please treat your instrument with care  Misuse such as tossing or  dropping the unit can potentially damage the weigh scale mechanism or other  parts of this device  Use a soft  clean cloth to wipe out the cell  using extreme  caution no to damage the grain temperature sensor at the bottom of the test  cell  It is important when emptying the tester to make sure there is no grain  lodged in the cell top ring  see page 16 for Troubleshooting      Display Reading   Moisture Limit Guidelines   Specifications and design subject to change without notice     MOISTURE RANGE MOISTURE RANGE  
15. isture calibration in the tester     TO ADJUST GRAIN OFFSET    1  Turn on Unit  press ON OFF button    2  Use UP DOWN buttons to scroll to    GRAIN OFFSET    then press ENTER  3  Use UP DOWN buttons to make the desired adjustment  4    Press ENTER to save this offset  or press back arrow to not save it     You are now back to active grain display where you are ready to test    Grain Offset     gt     Figure 10  GRAIN OFFSET    NOTE  The grain offset adjustment  bias calibration  is applied to the last grain  you tested  since a test must be made prior to knowing what adjustment to  apply     CLEAR GRAIN OFFSET   1  Turn on Unit  press ON OFF button    2  Use UP DOWN buttons to scroll to    GRAIN OFFSET    then press ENTER  3  Use UP DOWN buttons to make adjustment 0 0  4    Press ENTER  after displaying the save  disc  icon the unit takes you back  to the active grain display and ready to test         ee a a     Figure 11  GRAIN OFFSET       12    Operation    TURN BACKLIGHT ON OR OFF    To extend battery life turn your LCD display backlight    off    if you don t need it   When outside in the daylight you will likely not need the backlight on     TO TURN THE BACKLIGHT ON OR OFF     Turn on Unit  press ON OFF button   Use UP DOWN buttons to scroll to    SETTINGS    then press ENTER  Use UP DOWN buttons to scroll to    Backlight     Press    Enter    to toggle the backlight on or off  Press Back arrow when done    You are now back to the active grain display where you are read
16. mi level surface  surface e Repeat test  Grain weight greater e After swiping  make sure swiper is fully  16 than 330 grams returned  e Perform    Weight Test     17 Grain weight less than e Clean cell and top ring  50 grams e Perform    Weight Test     Grain weight more than   Meter automatically compensated for weight    20  higher than the     Scale is based on a different test weight  nominal weight e Clean top ring and perform    Weight Test       Grain weight more than   Meter automatically compensated for weight  20  lower than nominal     Scale is based on a different test weight  e Clean top ring and perform    Weight Test       20 Cup not empty in e Ensure cup is empty  measurement cycle   Repeat test    20       Warranty    WARRANTY    This product is guaranteed to be free from defects in materials and  workmanship for one  1  year from date of retail purchase  This warranty does  not cover the batteries or damage resulting from misuse  neglect  accident   or improper installation or maintenance  This warranty does not apply to any  product which has been repaired or altered outside an authorized factory repair  facility     The foregoing warranty is exclusive and in lieu of all other warranties of  merchantability  fitness for purpose and any other type  whether express or  implied  Agratronix neither assumes nor authorizes anyone to assume for it any  other obligation or liability in connection with its product and will not be liable  for consequential damages   
17. ows MOISTURE BELOW LIMIT or MOISTURE ABOVE  LIMIT     Solution 1  Grain may be too wet or dry to test  Check moisture limit guidelines  on page 3 of Operating Instructions     NOTE  Limits shown on page 3 are only guidelines and subject to change        16    Service    CHECK BATTERY POWER LEVEL AND REPLACE BATTERIES  The tester is supplied with four AA alkaline batteries     A     Battery Door  B     Batteries     4 AA alkaline batteries  NOTE  Remember to    remove batteries  when unit is not in      use after the season  VOI rrosion   A   to avoid corrosio    Figure 16  Battery Door and Batteries    CHECK BATTERY LEVEL    Turn on Unit  press ON OFF button   Use UP DOWN buttons to scroll to    SETTINGS    then press    ENTER     Use UP DOWN buttons to scroll to    Battery     Press    ENTER      Percent of battery life remaining is displayed  Figure 17   Press Back Arrow when done    Press Back Arrow one more time to return to active grain display where you  can take a test    Figure 17  Battery Percentage       17    Service    REPLACE BATTERIES    Per the above instruction  first  Check Battery Level     If battery level is lower  than 15  then it   s recommended you replace batteries with four  4  new AA  Alkaline Batteries  B      To replace batteries   Remove battery door  A   Figure 18   Remove and properly dispose of the four AA alkaline batteries  B     Replace with 4 new AA alkaline batteries  B   pay special attention to  the battery polarity        Replace and se
18. r  G  to the  top of the tester  see page 5 for instructions on securing hopper      2 When the grain to be tested has been selected using the UP DOWN arrows   D  fill the grain hopper  G   and pull hopper slide  H  to drop the grain into  the test cell  Allow grain to sit in the hopper as short of a time as possible  since the hopper temperature will alter the grain temperature     3  After 30 to 60 seconds  empty test cell and immediately refill with fresh grain     4  Take a test with this fresh grain  Now the test cell and grain should be close  enough in temperature to give a good reading     Note  The most accurate moisture measurements are achieved when the test  cell and grain temperature are similar     A    Test Cell   B     ON OFF Button   C     Display   D UP  DOWN Arrows   E     BACK Arrow   F     ENTER   TEST Button  G     Grain Hopper   H     Grain Hopper Slider          Level Arm with Brush     gt     Figure 1  AG MAC PLUS Unit       Operation    CAUTION  Please treat your instrument with care  Misuse such as tossing or  dropping the unit can potentially damage the weigh scale mechanism  or other  parts of this device  To add the ability to measure grain test weight results in a  more complex grain testing instrument     Use a soft  clean cloth to wipe out the cell  using extreme caution no to dam   age the grain temperature sensor at the bottom of the test cell  It is important  when emptying the tester to make sure there is no grain lodged in the cell top  r
19. splayed language     Language     gt     Figure 9  Language Selection    ADJUST GRAIN OFFSET    Let s start with an overview of grain offset  An offset is the way you adjust your  tester to your local grain elevator s table top tester  Some people call it a calibra   tion  some call it an offset  and others call it a bias but all three terms mean the  same thing  Let s say your tester measures a sample of corn at 15  moisture but  your local grain elevator tester measures it at 14 5   What you can do is pro   gram a 0 5  moisture  enter a  0 5   offset to your tester so it matches the grain  elevator     NOTE  It s not uncommon to take your load of grain to two different grain  elevators and get a different result from each of their grain elevator testers     NOTE  An offset adjustment can NOT be made to produce moisture readings  that are below or above the moisture limit for the selected grain     IMPORTANT  Always obtain three test results from the grain elevator for the  sample being compared  The unit will average these three results  Compare this  average with the average of three tests by your moisture tester before making an  offset adjustments        11    Operation    Each grain can be individually adjusted by 10 0  in increments of 0 1  to more  closely match the results of an elevator tester  The calibration adjustment typi   cally compensates for the differences in the variety hybrid of grain you are testing  relative to the varieties used to develop the grain mo
20. will be things you    do that are outside of the limits of the tester  or things that affect the   accuracy  There will also be some error codes that warn you about a  fault in your tester  Below is a list of the current error codes  Always check our web  site at www AgraTronix com  under the links for this tester  for the updated manual  to find all error codes        Error Code Cause Solution    Memory Failure e Call for service  1 800 821 9542   Grain Not Detected e Repeat test    e Grain in test cell too e Clean cell and top ring  soon e Repeat test     Weight Scale Defective    Perform    Weight Test       Weight did not settle e For better accuracy  place tester on a  within normal time limits non vibrating  semi level surface  Moisture measurement e Repeat test   took too long to settle    Same as 9  except tester   Put tester on non vibrating  semi level surface    stopped trying to find e Repeat test  stable weight    40 Grain temperature lower   Displayed moisture will be less accurate than  than 36F if the grain were at a higher temperature   13 Grain temperature higher   Displayed moisture will be less accurate than  than 122F if the grain temperature was below 122F    Large temperature Meter automatically compensated for  difference between the temperature difference  for better accuracy   14 grain and meter test cell   grain and meter test cell should be at similar  temperatures  e See Preheating Procedure    15 Not on a sufficiently level   Place tester on a se
21. y to test    Backlight     gt  MM    lt  Backlight On    Figure 12  Backlight    TEMPERATURE AND TEST WEIGHT UNITS    When the temperature units are changed from Fahrenheit to Celsius the test  weight units are also changed     e If you select Fahrenheit then you will get test weight in Ib bu  pounds per  bushel     e If you select Celsius then you will get test weight in kg hl  Kilograms per  Hectoliter     TO CHANGE TEMPERATURE AND TEST WEIGHT UNITS    1  Turn on Unit  press ON OFF button   Use UP DOWN buttons to scroll to    SETTINGS    then press ENTER  Use UP DOWN buttons to scroll to    Units     Figure 13   Press    ENTER    to toggle the between F  Fahrenheit  and C  Celsius     Press Back arrow when done  You are now back to the active grain display  where you are ready to test        13    Operation    Temperature  amp       Test Weight Units    Figure 13  Temperature and Test Weight Units    AUTO OFF SETTINGS   Auto Off setting allows you to select the length of time you want your tester to   automatically turn off     auto off  after the last button press  no activity   The  default setting of 5 minutes should suffice  but if not then change it to meet your  needs  Example  if your Auto off is set at    5 minutes    then if you turn your unit on   and walk away  and thus don t touch a button for 5 minutes  then your tester will  automatically turn off to conserve battery life     TO CHANGE YOUR AUTO OFF SETTING   1  Turn on Unit  press ON OFF button   Use UP DOWN 
22. yed  3  6 or 9   Press back arrow to return to the grain to be tested        lt  Number to  Average    Figure 4  AVG num Display in Menu    Example  You can take 3 consecutive moisture tests from the same batch of grain   If test 1 is 15 5  test 2 is 15 3  and test 3 is 15 7  then the average moisture dis   played will be 15 5   moisture  average of the 3 consecutive tests   The current  moisture is also always displayed for each test        Operation    Function 2     Clear AVG  Clear the current averaged moisture measurement  results and start a new average for your next consecutive measurements     1  Turn on Unit  press ON OFF button     2  Use UP DOWN buttons to scroll to  Clear AVG    then press ENTER  unit  displays the    disc    save icon so you know it reset the current averages     Clear Avg     gt     Figure 5  CLEAR AVG    SELECT A DIFFERENT GRAIN   1  Turn on Unit  press ON OFF button    2  Use UP DOWN buttons to scroll to desired grain then press ENTER  Top of  the display now shows your selected grain     New Grain     gt     Figure 6  GRAIN SELECTION       Operation    WEIGHT TEST     CHECKING TEST WEIGHT FOR ACCURACY    Weight Test     Allows user to check the calibration of the test weight function   of the tester  By following the steps indicated  the final reading will let the user  know if the test weight is off  Test weight reading errors could indicate that grain or  debris is stuck under the top ring or load cell is damaged  See page 18  Cleaning  the
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
12ft / 3.65m Combo - Global Trampolines  MV700A  Usuarios Finales con Linux. Manual de Configuración e Instalación.  Manuale installazione, uso e manutenzione RBS 24 RAIN  (EN): c5std_manual_en  Manuel d`utilisation - EV  Hunter Scope with H130/H59/H425 Manual      Milwaukee 2753-22 Use and Care Manual    Copyright © All rights reserved. 