1. For value 1 the LED is on and for value 0 the LED is off Note the channels stay in the HiZ position LEDs off until the ACKSYS driver has started PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 11 V WIRING V 1 SUBD62 connector pin assignment Signal Mnemonic Direction Pin N Pin N Pin N Pin N TxD Transmit Data Output A TxD Transmit Data Output B RxD Receive Data Input A RxD Receive Data Input B TxClkOut Transmit Clock Output A TxCIkOut __Transmit Clock Output B 14 6 235 9 RxClkIn Receive Clock Input A 13 6 2 8 RxClkIn Receive Clock Input B oN SS GND 5V useful in RS485 mode for specifying the 43 48 53 59 polarisation PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 12 V 2 Pin assignment for the 4P570M25 cable DC _ a gt SUBD HD62 MALE Z E _ 4PS7OM25 NL M Important before connecting the 4P570M25 cable to the WAN HDLC 4 board Switch off the PC The signals associated with the serial channels 1 2 3 and 4 are assigned respectively to the connectors
2. define MCX_AREA MEMORY 0 acces to mailbox long StartAddress starting address of access relative to the base port or the start of the mailbox long Length length to transfer unchar Buffer 1 values to write if MCX_AREA_SET MCX_AREA DESCRIPTOR PMCX_AREA DESCRIPTOR define MCX AREA DESCRIPTOR_SIZE dlen dlen sizeof MCX_ AREA DESCRIPTOR 1 structure for IOCTL SERIAL SI ONS typedef struct _MCX_ OPTION long Option option code define MCX_OPTION_GET_CHANNEL 0x20002 get channel n define MCX_OPTION_SET_DSR_RI_INVERSION 0x30100 exchange DSR RING define MCX_OPTION_GET_DSR_RI_INVERSION 0x40001 get DSR RING state define MCX_OPTION_GET_COMPATIBILITY 0x50004 get current Compatibility union long Long 1 short Short 1 unchar Char 1 Value parameters used by option MCX_OPTION PMCX_OPTION define MCX_OPTION_SIZE dlen dlen sizeof MCX_OPTION sizeof long PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 37 I 2 SET GET SYNC STATE functions Two functions have been added to customise the format of synchronous frames include windows h include winioctl h include mcc_mcex h DeviceloControl ADevice IOCTL_SERIAL_SET_SYNC_STATE
3. displays on line help The MCCIOCTL utility can be used to send the command as an argument directly to the board The MCCIOCTL command entered without parameters displays on line help The DOSDEV utility manages the links between the names of Windows NT objects and DOS peripherals It remains effective until the system is shut down The syntax is as follows dosdev lists the aliases dosdev 1 COMn Device McxCNN creates the COMn alias for the McxCNN device dosdev r COMn deletes the COMn alias where n is the number of the COM port C is the number of the MCX board and NN is the number of the channel on the board The SETMCX utility can be used to display or modify a board s parameters from the command line or in a batch process SETMCX on line help SETMCX n displays all the parameters of board n SETMCX n param displays the value of the param parameter for board n SETMCX n param val assigns the value val to the param parameter for board n SETMCX n Compatibility code code adds removes the code bit to from the configuration options PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 34 I DETAILED REFERENCE MANUAL The driver specific functions can be accessed via DeviceloControl They use definitions and structures described in mec_mex h or in mexproto h for functions that are specific to Multiprotocol mode IL 1 include mcc_mcx h Extract from the mcc
4. free command CloseHandle hDevice return TRUE PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 46 Appendix flow control The boards in the MCX range equipped with the MCX MULTIPROTOCOL option and used with a version of the driver later than 1 7 0 support all the flow controls offered by the Win32 API and even some additional controls accessible by executing the VMODE command directly The restrictions affecting the operation of flow control are described below Methods supported The following flow control options are supported none XON XOFF configurable DTR CTS RTS CTS In all cases both transmission directions are controlled The two directions cannot be configured independently Configuring the control method The SetCommState service and the interpretation of the fields in the DCB structure see page 26 have been adapted to address these constraints The use of the Multiprotocol option and the board configuration options i e the Register Synchronous and Compatibility values also affect operation Flow control is consequently supported as follows a if the Synchronous indicator is set to 1 with an old driver and or old firmware flow control will not be supported because the board does not support the VMODE command b otherwise if fInX or fOutX is TRUE flow control is XON XOFF with the XonChar and XoffChar characters c otherwise if fRtsControl
5. frameFormatBuffer sizeof MCX_SYNCHRONIZATION_PARAMETERS NULL 0 pcbBytesReturned IpoOverlapped DeviceloControl iDevice IOCTL_SERIAL_GET_SYNC_STATE NULL 0 frameFormatBuffer sizeof MCX_SYNCHRONIZATION_PARAMETERS lpcbBytesReturned lpoOverlapped HANDLE ADevice Handle of the device PMCX_SYNCHRONIZATION_PARAMETERS frameFormatBuffer pointer to parameters LPDWORD pchBytesReturned size of returned params LPOVERLAPPED poOverlapped overlapped struct addr The SET function can be used to select the frame format HDLC etc The integer pointed to by pcbBytesReturned always takes the value 0 WARNING in driver versions earlier than 1 8 3 this function returns an error if the state of the port set previously by SetCommState contains options not supported by the board e g ByteSize 7 in HDLC mode In the later versions the port is forced to a reasonable state The GET function consults the current frame parameters The integer designated by IpcbBytesReturned always takes the value sizeof MCX_SYNCHRONIZATION_PARAMETERS The MCX_SYNCHRONIZATION_PARAMETERS structure is made up of the following items UCHAR SynchronousMode Protocol MCX_SYNC_HDLC MCX_SYNC_BISYNC MCX_SYNC_LAPB or MCX_SYNC_CHAR The MCX_SYNC_CHAR mode corresponds to asynchronous transmissions LAPB is also known as HDLC ABM UCHAR Duplex Simultaneous transmission MCX _WAY_FULLDUPLEX simultaneous transmission and reception
6. the signal format the frame format the protocol or the flow control etc Each channel can be driven by a different application if necessary The file name used to access the channels is defined when the board is configured If the usual name is not COM the channels will be numbered 01 02 etc up to the number of channels installed on the board If the usual name is COM the channels will be numbered without the leading zero as from first port number For example Channel identification V COM3 COM4 etc cem o Yocom VV COMO et Vs Mex101 Mex102 ete NU MEXBOL ete The available APIs are based on the Win32 documentation and fall into three groups file services CreateFile ReadFile etc communication services SetCommState etc and the DeviceloControl file service which is used by all the driver specific functions that are not provided in Win32 change of protocol or electrical interface etc In the following pages the APIs are presented according to whether they are used in asynchronous communications synchronous communications amp LAPB communications driver specific services utilities PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 25 I 1 Programming asynchronous communications For general information consult Microsoft s Win32 documentation The details below simply concern cases in which the driver
7. Int error at MCXPCI end Or MCXPCI error when reading FIFO Code SBB a aaia SCC error during high speed DMA test Code SC General protection fault Code SD ans sn a lois uae Memory size error Code BE siennes in sin ss NMI interrupt received Code g Bis star nn cheat res Error on 100 us counter Phase N 2 before the PC driver is loaded When the self test phase has been successfully executed the DLO thru DL7 LEDs are lit up in rotation Phase N 3 after the PC driver has loaded DLO flashes once per second and indicates that the board is active DLI the board executes a command DL2 the board has sent an interrupt to the PC that has not been acknowledged DL3 Reception in asynchronous mode on one or more of the 4 channels DL4 Transmission in asynchronous mode on one or more of the 4 channels DLS Reception in synchronous mode on one or more of the 4 channels DL6 Transmission in synchronous mode on one or more of the 4 channels DL7 Reception error on one or more of the 4 channels PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 10 IV 4 LEDs installed on the mezzanine board Each channel has a group of 8 LEDs that indicate whether the interface has been programmed for RS232 V35 RS422 RS485 or High impedance also called HiZ J4 connector reserved for ACKSYS SUDB62 for 4P570M25 cable
8. Serial printers Because of a fault in the Windows NT 3 51 Print Manager you should proceed as follows to create a printer Use the Ports icon in the Control Panel to modify or at least display the parameters for the particular port You must use the lt OK gt button to validate Use the Services icon in the Control Panel stop the service called Spooler and restart it immediately This will recognise the new ports and its parameters Printers icon in the Control Panel in the Print Manager go to the Printer menu and select lt Create a printer gt Fill in the form the port should appear in the lt Print to gt list The installation procedure ends here Command exe command line prompt in the DOS window The names COMI thru COM9 can be used directly here Otherwise use the standard names name assigned on installation for example to redirect console output C gt DIR gt COM9 Either format may C gt DIR gt COM9 be used C gt DIR gt AN COMTO This is the only format authorised if the installed name is COM C gt DIR gt MCX101 This is the only format authorised if the name is MCX1 PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 33 1 6 Other utilities The MCXMODE utility can be used to customise the transmission characteristics in synchronous or asynchronous mode The MCXMODE command used without parameters
9. board ss 8 IV 4 LEDs installed on the mezzanine board se 10 V WIRING aperas aaao antea ven nu once and na 11 V 1 SUBD62 connector pin assignment sus 11 V 2 Pin assignment for the 4P570M25 cable sise 12 V 3 Th electrical int rfaces sas sn datitsemsninnninbninniinennniimitinteneneieniotnnte 14 VI NT 2K DRIVERS ne anna annee ns 15 VI 1 REDODD eeose sate ere ete nen ee ne cosas ee ere nine rare tnt ee entree nette ste E E ee lee tete am eebe te due du 16 VI2 Installation and configuration ss 17 VI3 Configuring installed boards ss 19 VI 4 Board properties e E nn EA EE E E es 20 VIL CHECKING THE INSTALLATION nent en net Sn nie 22 VII D VELOPPEMENT TOOLS AND EXAMPLES o scsssesssesernsonninscetanscansoneooneseeaneunianesiensteqsenasoness 23 COM COMPATIBILITY MODES sivsssssssesssessccosssseseossesacscossssnssssscasessesseasssssccssesvssessseszesetee 24 I APPLICATION PROGRAMMING INTERFACE APT 24 I 1 Programming asynchronous communications 25 I 2 Programming synchronous communications ss 27 1 3 Programming the LAPB or HDLC ABM protocol 29 14 Programming driver specific Services sise 31 1 5 Standard Windows NT utilities sise 32 1 6 Other WENT SS is 25 in ear EEEE ttes een it e EA dan ti eteennni ententes is 33 I DETAILED REFERENCE MANUAL i5 saiscenncaatvasnatcnviaateadssynabastaandandcvasaviedaswadtasssnacdadeouacedeies 34 IL1 Extract from the Mex h Hee scscsccccascsccacsscscoscsseavsscds
10. driver The channel names are formed by concatenating the fixed character string the usual name and the number in the sequence starting with first port number The Resources tab is only available for an ISA bus The Advanced tab gives access to the options and compatibility with earlier versions of the driver 1 6 4 thru 1 8 3 This does not apply to WAN HDLC boards that are only fully supported as from version 2 1 0 of the MCX driver PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 22 VII CHECKING THE INSTALLATION You can check that the driver has been properly started by consulting the Event Viewer which displays two messages about the driver a a message indicating that the driver has been loaded and its version b for each board installed a message indicates the version of the EPROM the number of channels recognised by the board and other items of useful information In Windows 2000 You can check that the driver has been started correctly by consulting the Device Manager accessible notably by clicking with the right hand mouse button on the Workstation icon WARNING when you have installed a new driver the General tab will tell you that there is a problem with a device Ignore this message which should disappear the next time you reboot the system This message has no impact on operation the driver will function correctly as soon as it has been installed
11. frame whose size is limited to the value specified by the IOCTL_SERIAL_SET_SYNC_STATE command WriteFile ends as soon as the outgoing characters are no longer in the board s buffer and not when they are effectively transmitted CloseHandle ends by deleting the transmit buffer and opening circuits 105 and 108 RTS and DTR It is advisable to use FlushFileBuffers before CloseHandle to ensure that all the data in the buffer has been transmitted FlushFileBuffers ends with the transmission of the flag of the last transmitted frame by the immediately preceding WriteFile This guarantees that the board s buffers are empty Serial communication services Service BuildCommDCB BuildCommDCBAndTimeouts ClearCommBreak ClearCommError Comments unrestricted See the comments for SetCommTimeout No effect The BREAK ends automatically after one second Only the CE BREAK CE FRAME CE_OVERRUN and RXPARITY bits in pdwErrors are supported In the COMSTAT structure only the cbInQue and chOutQue fields are supported they specify a number of frames and not a number of characters PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 28 EscapeCommFunction CLRDTR CLRRTS SETDTR SETRTS SETBREAK are supported CLRBREAK see ClearCommBreak SETXON and SETXOFF are not supported GetCommMask unrestricted GetCommModemStatus see Appendix limitations and diff rences with the COM ports page 48 G
12. gt include lt windows h gt include lt winioctl h gt include lt mcc_mcx h gt BOOL Relrp PMCC_CMD command space for RELRP and its parameters DWORD retLen length returned by DevicelIoControl int cmdLen length of command structure int dataLen Length of the RELRP Data area HANDLE hDevice one of the channels must be used any one will do hDevice CreateFile COM3 GENERIC _WRITE GENERIC_READ 0 NULL OPEN_EXISTING FILE ATTRIBUTE NORMAL NULL init opcode and data see RELRP command in basic software or multiprotocol documentation dataLen 18 cmdLen MCX DIRECT _IO BUFFER SIZE datalLen command malloc cmdLen command gt Cb opcode RELRP command gt Cb length datalLen the following assignment distinguishes the MCC boards which do not modify data item 18 command gt Data 18 1 MCX TYPE MCC if DevicelIoControl hDevice IOCTL_SERIAL CMD command cmdLen command cmdLen amp retLen NULL printf RELRP Win32 error d n GetLastError return FALSE if command gt Cb status 0 f printf RELRP failed status d n command gt Cb status return FALSE printf RELRP carte type d a d MHz d canaux n command gt Data 18 1 command gt Data 1l 1 command gt Data 9 1
13. is set to RTS_CONTROL_HANDSHAKE flow control is implemented by hardware with the RTS and CTS signals d otherwise if fOutxCtsFlow is TRUE or fOutxDsrFlow is TRUE or if fDtrControl is set to DTR_CONTROL_HANDSHAKE flow control is implemented by hardware with the DTR and CTS signals e otherwise there is no flow control Compatibility with earlier versions Earlier versions of the boards and software did not support flow control by RTS CTS In any of the following cases the driver version is 1 6 2 or earlier the EPROM 1 8 3 8 configuration option has been validated the version of the board firmware is earlier than 1 8 Rules c and d must be combined into a single rule c d otherwise if fOutxCtsFlow is TRUE or fOutxDsrFlow is TRUE or fDtrControl is set to DTR_CONTROL_HANDSHAKE or fRisControl is set to RTS_CONTROL_ HANDSHAKE flow control is implemented by hardware with the DTR and CTS signals Note To ensure compatibility with future versions use the combination that matches the cable you are actually using e g if the incoming control signal is on CTS use fOutxDsrFlow to manage it instead of fOutxCts Flow PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 47 Ill APPENDIX SPECIFIC ERROR CODES The error codes returned by the Win32 API are as described in the API documentation Here however is a selected list of error codes that are not easily understood 2 ERROR FILE NOT FOUN
14. or MCX_WAY_HALFDUPLEX alternating transmission and reception see the details of this mode in the Multiprotocol Manual DT003 Important most of the functionalities used in half duplex mode can be activated by correctly configuring the full duplex mode Half duplex mode should only be used when it is really necessary it is the only way to prevent transmission when reception is in progress Half duplex mode forces fOutxCtsFlow TRUE fRtsControl RTS_CONTROL_TOGGLE and ignores data received without DCD It prohibits transmission when DCD is active and also when DSR is active with fDsrSensitivity TRUE PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 38 UCHAR TransmitClockSource Transmit clock source see below UCHAR ReceiveClockSource Receive clock source see below Constat clock source MCX_CLOCK_RXC in 17 RxClock MCX_CLOCK_TXCI in 15 TxClock MCX_CLOCK_BRG internal bauds generator MCX_CLOCK_DPLL decoded in data only with FM or Manchester coding UCHAR TxClockPinSource Clock source available on pin 24 Warning this pin is disabled if MCX_CLOCK_TXCT is used by TransmitClockSource on ReceiveClockSource MCX_CLOCK_TRXC_HIGH none pin set to MARK state MCX CLOCK_TXCLOCK like TransmitClockSource MCX_CLOCK_ internal bauds generator CxX_CLOCK_ BRG M DPLL decoded in data only with FM or Manchester coding UCHAR MonosyncChar First sync character in BISYN
15. the A and B signals are connected to a 120 Ohm terminal resistor The polarisation resistors should be built into the connection cable To polarise a pair A B connect a 470 to a 1K 1 4W 5 resistor between signal A and the signal ground GND pin 7 or 26 and between signal B and the 5V power supply pin n 25 PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 15 VI NT 2K DRIVER The following diagram shows how the driver is installed in the Windows architecture Applications ACKSYS specific DeviceloControl API files API CreateFile communications ReadFile etc Win32 ieee Eee Win32 Communications Windows NT DeviceloControl LAT COM driver D ACKSYS y WANHDLC board Standard DeviceloControl COMM compatible modes Serial channels The diagram shows that the driver uses the same API as the COM ports If a specific application needs to use board features without accessing them via the Win32 API it can access the driver or even the board directly via the DeviceloControl commands described in the section entitled COM COMPATIBILITY MODES Typical examples of this are switching to RS422 or HDLC mode PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 16 VI 1 Reboot You must install the board in the computer before starting the installation program Otherwise the program will not be able to recognise the board and allocate resources autom
16. 19 VI 3 Configuring installed boards The list in the lower half of the window indicates the boards that have already been detected or installed and their main characteristics A red icon indicates that boards have been detected but that they are not yet configured and cannot be used You must configure them before they can be used A yellow icon indicates that boards are inhibited In other words these have been deliberately placed out of bounds you have checked the inhibit box in the board properties You can re enable this board before it can be used A green icon indicates that enabled PCI boards have been recognised Boards with this status can be used You can access a board by selecting it then using either of the buttons at the bottom of the window or clicking with the right hand mouse button Double clicking opens the properties window see below The Add button lets you define an ISA board and is therefore not discussed in this manual The Tesi button lets you run some basic checks on the operation of a selected board and displays a report after a few seconds The Quit button checks that after a board has been modified the same resources are not being used by several boards offers some installation advice then ends the program The Print all button accessible if no board has been selected prints a summary of the configuration of each board This button changes to Print when a board has been selec
17. C mode The only sync character in MONOSYNC mode Ignored in the other modes UCHAR BisyncChar Second sync character in BISYNC mode Ignored in the other modes UCHAR Version Version of the structure Should always 1 USHORT Options Protocol options Each option is a bit that must be added if the option is to be used e MCX HDLC _USERDTR enables the use of the CCITT 108 DTR circuit in HDLC LAPB and X25 modes on channels 1 2 and 3 of the MCX and MCX Lite S boards However this will limit the performance levels e MCX HDLC _ SPECS forces the use of the elements of the Protocol Hdlc structure which are ignored otherwise e MCX _BISYNC_SPECS forces the use of the elements of the Protocol Bisync structure which are ignored otherwise USHORT DataLength Maximum frame length If the value is set to 0 the default length will be used see the PROTO command in the Multiprotocol documentation DT003 union Protocol The sub structures specified here can be used to specify the parameters for a specific protocol See the PROTO documentation in the Multiprotocol Software User Manual DT003 PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 39 The following should be specified for LAPB only UCHAR Protocol Lapb Role MCX_ ROLE _ CLIENT if the application acts as a client ETTD MCX_ROLE_if the application serves the network UCHAR Protocol Lapb K N2 T1 T2 T3 Standardised LAPB
18. D The driver has not started Consult the Event Viewer and the Device Manager 5 ERROR_ACCESS_DENIED The channel has already been opened by another process 21 ERROR NOT READY In WriteFile transmission is impossible because the Data Link layer LAPB is not connected 23 ERROR_CRC In a ReadFile this error indicates that the received frame contains an error all types of error generate this error code and not just CRC errors 38 ERROR HANDLE EOF In LAPB protocol indicates that the Data Link layer is disconnected before or after the execution of a ReadFile and that there is no outstanding frame in the receive buffer 57 ERROR_ADAP_HDW_ERR Unexpected error on the MINTR command Probably a board malfunction 87 ERROR_INVALID_PARAMETER 1 In DeviceloControl WaitCommEvent ReadFile and WriteFile this error can in particular indicate that the poOverlapped parameter does not match the options requested in the CreateFile either that or the hEvent element in the OVERLAP structure is incorrect 2 In DeviceloControl either one of the parameters or one of the elements in the structure supplied in the third parameter position is incorrect 122 ERROR_INSUFFICIENT_BUFFER 1 The length specified in DeviceloControl is wrong 2 In DeviceloControl the value of the Cb length element in the IOCTL_SERIAL_ CMD or CMD_AUTO function is too small 995 ERROR_OPERATION_ABORTED 1 The board did not answer a command within the timeout The most l
19. LC_SPECS 2 Use the Protocol Hdlc struct below A define MCX _BISYNC_SPECS 2 Use the Protocol Bisync struct below McxUnshort DataLength max frame size LAPB N1 union struct unchar RxFrames default 14 unchar TxFrames default 4 McxUnshort Sparel reserved set to zero McxUnshort Spare2 reserved set to zero McxUnshort Spare3 reserved set to zero McxUnshort Spare4 reserved set to zero McxUnshort Spare5 reserved set to zero Hdlc Bisync define MCX _HDLC_DEFAULT 0 default for theses fields struct unchar Role default CLIENT define MCX_ROLE CLIENT 1 define MCX_ROLE NETWORK 3 unchar K default 7 McxUnshort N2 default 10 essais McxUnshort T1 default 2550 ms 2 McxUnshort T2 default 0 McxUnshort T3 default infinite McxUnshort Spare reserved set to zero define MCX _LAPB DEFAULT 0 default for theses fields Lapb Protocol MCX_SYNCHRONIZATION PARAMETERS PMCX_SYNCHRONIZATION PARAMETERS PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 structure for IOCTL SERIAL ACCESS AREA typedef struct _MCX_ AREA DESCRIPTOR long Operation combin of the following flags define MCX AREA GET 0 board to application define MCX_AREA SET 1 application to board
20. Size The _MCC_CMD structure contains the following elements unsigned char Cb opcode Code of the command that is to be executed mcc_mex h defines the symbolic names for these codes unsigned char Cb status The returned result supplied by the board in the STATUS zone unsigned char Cb par 76 The command parameters returned parameters for some commands unsigned char Cb ichan unsigned char Cb icond Returns a copy of the mailbox INTERRUPT unsigned char Cb iparl Zone heoretically these five elements are not unsigned char Cb ipar2 used unsigned char Cb ipar3 unsigned char Cb data Unused in Windows NTE unsigned char Cb kdata Field used temporarily by the driver during command execution unsigned short Cb length Working length of the data zone in bytes unsigned char Data 0 Data zone that will be exchanged with the board s mailbox because this zone must immediately follow the Ch structure the MCC_CMD variable length structure is used except for the LDIAL command used by the MCC board gt In a UNIX environment pointer to the data zone that will be exchanged with the board s mailbox This zone is not used in the UNIX driver PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 43 Notes amp To avoid errors it is advisable to include the same pointer in paramsFromAppToBoard and paramsFromBoardToApp and the same length in paramsAppSize and paramsBoar
21. The options in the Driver tab let you stop restart or inhibit the driver In Windows NT 4 You can check that the driver has been started by consulting the Devices icon in the Control Panel PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 23 VIII DEVELOPPEMENT TOOLS AND EXAMPLES You can communicate with the driver via your C language source programs either through the standard functions of Win32 e g CreateFile etc or with the commands and structures that are specific to your driver The following files will be useful for developing your own applications A WWINNT SDK INCLUDE MCC_MCX H A WINNT SDK INCLUDE MCXPROTO H If necessary copy these files on to your hard disk so that they can be accessed by your C language source programs You will find sample programs in A WINNT SDK More specifically the SDK MSVC LIB directory contains a library of functions that are useful for getting to know the driver these functions use the header SDK INCLUDE ACK_W32 H and are compiled with the MultiThread option in the SDK LIB MCC_MCX LIB library PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 24 COM COMPATIBILITY MODES The following sections describe how the driver operates with the MCX MULTIPROTOCOL on board firmware I APPLICATION PROGRAMMING INTERFACE API Each serial channel can be programmed independently whether as regards the electrical interface
22. WAN HDLC 4 USER MANUAL For Windows NT 2000 XP INTELLIGENT COM PORTS WITH MULTIPROTOCOL SUPPORT ACKSYS COMMUNICATIONS amp SYSTEMS 10 rue des Entrepreneurs ACKSYS ZA Val Joyeux Tel 33 0 1 30 56 46 46 78450 VILLEPREUX Fax 33 0 1 30 56 12 95 Web www acksys fr FRANCE Hotline support acksys fr Sales sales acksys fr Important The ACKSYS Windows Device Driver is common to all Windows Operation systems NT 2000 and XP TABLE OF CONTENTS LT PRESENTATION ovessd sssisisaeesccacietssassandaca dons a e sean tte esse sb ngtentulenuste dos ossi leon dehe ns inse 4 Il OPERATIONAL RESTRICTIONS ccscessessssececcceceesenssececececeesesesesaecececcesenesesaseeeseesesesensaaees 5 Il SUPPORTED PROTOCOLS AN OVERVIEW cccssesssscecececeesessnssaecececeeseseseaaseeeceeeesesensaaees 5 IL 1 ASYnChronOUS WOE sssrini ris ee ee E otehsevasdsnsiens ere t uen sde nb tension EE EEEE tite a te 5 IIL2 Synchronised asynchronous mode ses 5 II 3 MONOSYNC and BISYNC modes esne eneen are en einiaid a aae 5 MI 4 Raw HDLG Modenpranrnicniseinn neni a aeo E AEE eA E aE Aia iaaa REE LER AiR 6 LS HDLC ABM of LAPB mode ac j csccssecsectieidcs csndesnensbdedennsnsecpunhbastbsapecscseqeuasededeesosdecbunshlesenseteressesbaaesectes 6 IV PHYSICAL BOARD INSTALLATION encens 7 IV 1 SW1 SW2 and SW3 switch settings ss 7 IV 2 Starting the Doat errer ineen ieri ne Ereren E e o EERE SEEEN E AE EE EE EE EEEE 8 IV 3 Diagnostic LEDs on the main
23. _mex h file serial IOCTL codes for Windows NT if defined CTL_CODE amp amp defined FILE DEVICE SERIAL PORT define MCX_IOCTL code CTL_CODE FILE_DEVICE_SERIAL PORT code METHOD_BUFFERED FILE ANY ACCESS define OCTL_SERIAL_GET_SYNC_STATE MCX_IOCTL 0x901 define OCTL_SERIAL_SET_SYNC_STATE MCX_IOCTL 0x902 define OCTL_SERIAL_CMD MCX_IOCTL 0x903 define OCTL_SERIAL_CMD_AUTO MCX_IOCTL 0x904 define OCTL_SERIAL_ACCESS_AREA MCX_IOCTL 0x90A define OCTL SERIAL MCX OPTIONS MCX_IOCTL 0x90B endif Windows NT macros and stru ed ed ed ed ed ed ed ed ed ed ed ed ch ch ch ch ch ch ch ch ch ch ch sh nsign sign sign sign sign sign sign sign sign sign sign sign e Apa Hed te En ea e TE ES By signed sh mcc_cmd typedef struct _MCC_CMD mcc_cmd Cb unchar MCC_ CMD size cts for CMD amp CMD_AUTO typedef struct mcc_ cmd ar ar ar ar ar ar ar ar ar ar ar Ori Ori opcode status par 76 ichan icond iparl ipar2 ipar3 paddingl data kdata length Cri hi Data 1 PMCC_CMD assigned to contain the struct _MCC_CMD padding2 buffer for ioctls CMD RECT define MCX len _IO BUFFER S sizeof mcc_cn ZE data
24. an example of how to use the command see the program source a winnt sdk msvc utils mcxmode c PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 29 I 3 Programming the LAPB or HDLC ABM protocol In addition to the specific details provided below on the programming of a LAPB connection see the previous section describing synchronous connections in general The informations below are necessary to program a LAPB link Note that the MCXMODE utility has some limited capabilities for managing the Data Link layer These can be used in particular in the test phase See the directory WINNT SDK MSVC LIB for programming samples Primitives linked to the use of LAPB Service Comments CreateFile Keeps the current protocol the electrical interface and the transmission speed Reactivates the signal management mode Purges the receive buffer CreateFile does not attempt to create the connection CloseHandle Purges the transmit buffer In LAPB mode the receiver is not inhibited Protocol frames can thus be received and answered CloseHandle does not attempt to break the connection ReadFile Reads a frame in the board buffer or awaits the arrival of an information frame Returns ERROR HANDLE _EOF if the link is disconnected or broken during the wait ReadFile is subject to the timeouts set by SetCommTimeouts WriteFile Places a frame in the transmit buffer and waits if the buffer is full Returns ERROR NOT_READY
25. an use the box to temporarily inhibit an installed board or temporarily delete a board from the computer without generating messages in the Event Viewer Model Selects the board model Only models that correspond to the bus being used will be displayed in this list The model must be specified accurately as other options depend on your choice Operating mode This mode corresponds to the settings of the SW1 1 and SWI1 2 switches For the WANHDLC board select multiprotocol 14 7456 MHz baud generator Does not apply to WAN HDLC boards Initial electrical interface Specifies the electrical interface that the driver will use to initialise on PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 Usal name First port number Example 21 all the channels If you want to program the channels with different interfaces leave the HiZ setting here and assign the interfaces at application program level Prefixes the name that will be used to identify the board s channels COM can be specified to use standard tools like Hyper Terminal By specifying another name you can use channel names with a fixed format see later the description of the CreateFile This number will be assigned to the name of the board s first channel The other channels will be numbered sequentially starting with this number This displays the name of the board s fist channel as it will be recognised by the
26. atically Users of Windows NT 4 need simply to check that the Service Pack installed on the system is later than or identical to the SP3 and then go on to the next section When Windows 2000 users install the board and then reboot their computer a new unknown device is detected automatically Nouveau mat riel d tect A PCI Device Veuillez patienter Board installation is not integrated in the Plug and play environment This means that before using the installation program supplied by ACKSYS see next section you will have to disable the plug and play capability for this device To do this here is the dialogue that you should follow with Windows 2000 Add new hardware Wizard Assistant Mat riel d tect Assistant Ajout de nouveau mat riel d tect p riph riques mat riels Cliquez sur Suivant pour continuer Cet Assistant vous permet d installer des pilotes pour les Install hardware device drivers Assistant Mat riel d tect Un pilote de p riph rique est un programme qui permet un p riph rique mat riel d tre pris en charge par un syst me d exploitation Installation de pilotes de p riph riques mat riels CS S DEEE Annuler Cet Assistant va terminer l installation de ce p riph rique ay PCI Device Un pilote de p riph rique est un programme logiciel qui permet amp un p riph rique mat riel de fonctionner Windows a besoin de fichiers de pilote
27. connections that may occur by analysing the errors returned by ReadFile and WriteFile With this method a LAPB channel can be used as a filter with the system s standard commands by establishing and breaking the connection with the MCXMODE utility E The second method consists of using the PRCTL ABMSTATE to query the channel E The third method consists of using WaitCommEvent to instantly detect state changes that have been caused by the board or by the other end of the connection As a rapid sequence of events can result in just one wake up of WaitCommEvent it is advisable to systematically query the channel state after a wake up and to consider that some steps in the sequence of states can be ignored Note that the events are memorised as soon as they are selected by SetCommMask and that subsequently one or more events occurring between two consecutive WaitCommEvent services cannot be lost but may be combined into one event All three sources of information should be used in a complete process I 4 Programming driver specific services The Win32 DeviceloControl function has been extended to dialogue directly with the software installed on the board This makes it possible to send the commands manually i e bypassing the driver For details of these commands see the MCX board basic software user manual and the MCX board multiprotocol software user manual For a full description see page 41 and for an example of how to
28. currence of a flag between a frame s start and end flags PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 IV PHYSICAL BOARD INSTALLATION IV 1 SW1 SW2 and SW3 switch settings SW1 1 and SW1 2 are set to OFF Mode Built in firmware SW1 3 set to ON Watchdog enable SW1 4 set to ON Reserved SW2 1 set to ON Battery Enable SW2 2 set to OFF Reserved SW3 1 and SW3 2 set to OFF Reserved PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 IV 2 Starting the board Each time the board is reinitialised powered up or reset all the channels are reset and initialised in high impedance mode An on board self test program is run automatically and displays a code identifying the current test on a group of 8 diagnostic LEDs numbered DLO DLI to DL7 If a test returns an error the program stops leaving the code of the current test displayed on the LEDs When all the tests have been successfully executed this takes around 15 seconds the self test program lights up and switches off each of the LEDs in rotation indicating that the board is now awaiting an instruction from the PC driver before continuing initialisation This provides a visual indication that there is no major operational defect on the board When the PC driver has been successfully loaded the board stops the rotating LED display and flashes the DLO diagnostic LED on and off once per second IV 3 Diagnostic LEDs
29. dSize amp To ensure compatibility with the UNIX driver we suggest initialising params FromAppToBoard Cb data paramsFromAppToBoard Data amp To avoid confusion between Cb par which starts at Cb par 0 and the command description which starts at PARAMETER 1 it is advisable to reference PARAMETER N by paramsFromAppToBoard Cb par N 1 to quote the PARAMETRE N Interactions between these functions and normal driver operation The description below is up to date for version 1 8 3 of the driver These interactions may change in future versions ALLOC The driver detects this command and if necessary adjusts the buffer size information It can consequently replace SetupComm which is ignored CHDEF A CHDEF is executed by the driver during SetCommState if an attempt is made to change DCB EvtChar In this case only EvtChar is included in the CHDEF command MINTR This command is executed during CreateFile CloseHandle DeviceloControl OCTL_SERIAL_SET_SYNC_STATE SetCommMask if the EV_RXFLAG is activated or deactivated and in some cases during ReadFile The activated sources are IT1 IT2 bit Mde 1 IT3 Gf EV_RXFLAG is active ITS IT6 IT7 PROTO The driver detects this command and adjusts its own protocol information It can consequently replace DeviceloControl SET_SYNC_STATE to enable the use of non standardised parameters this does not disrupt driver operation The VINIT RXENB MINTR and in some cas
30. differs from Win32 serial communications specifications cases in which the Win32 documentation is vague cases where the specification is not easily understood File services Service Comments CreateFile after CreateFile the transmit and receive buffers are empty WriteFile the number of outgoing characters must be less than or equal to 8 192 bytes WriteFile ends when the outgoing characters are in the board buffer and not when they are actually transmitted CloseHandle CloseHandle ends by deleting the transmit buffer and opening circuits 105 and 108 RTS and DTR It is advisable to use FlushFileBuffers before CloseHandle to ensure that all the data in the buffer has been transmitted Serial communication services Service Comments BuildCommDCB unrestricted BuildCommDCBAndTimeouts Same comments as for SetCommTimeout ClearCommBreak No effect the BREAK ends automatically after one second ClearCommError Only the CE_BREAK CE_FRAME CE_OVERRUN CE_RXPARITY bits in pdwErrors are supported In the COMSTAT structure only the cbInQue and cbOutQue fields are supported EscapeCommFunction CLRDTR CLRRTS SETDTR SETRTS SETBREAK are supported CLRBREAK see ClearCommBreak SETXON SETXOFF are not supported GetCommMask unrestricted GetCommModemStatus see Appendix limitations and diff rences with the COM ports page 48 PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 26 GetC
31. e transmit receive clocks can be configured internally externally or in data III 1 Asynchronous mode This is the mode used by traditional PC COM ports II 2 Synchronised asynchronous mode This mode is identical to asynchronous mode above except that the transmit or receive clock can be external to the board IL3 MONOSYNC and BISYNC modes xS YNC is a mode in which the board only manages a frame envelope In transmission mode the board encapsulates the data for transmission buffer used by the WriteFile function in a synchronous frame which looks like this S1 S2 OUTGOING DATA where S1 is the synchronisation byte in MONOS YNC mode or the first synchronisation byte in BISYNC mode and S2 is the second synchronisation byte in BISYNC mode The PC sends only the outgoing data block to the board which handles frame transmission In reception mode if the board receives a frame of the following type S1 S2 FIXED LENGTH INCOMING DATA The board handles the acquisition of the frame and stops data reception after n bytes n is customisable and sends only the incoming data block to the PC buffer used by the ReadFile function In Monosync mode the board uses an 8 bit synchronisation called S1 In Bisync mode the board uses a 16 bit synchronisation called S1 S2 PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 IIL4 Raw HDLC mode RAW HDLC is a mode in which the board only manages
32. es VMODE EscapeCommFunction commands must then be executed to position RTS and DTR and PurgeComm to purge the buffers RSMDE No undesirable interaction PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 44 ILS Samples of CMD and CMD_AUTO Set422 switches an MCX serial channel to RS422 by sending the RSMDE command to the board s firmware include lt stdio h gt include lt stdlib h gt include lt windows h gt include lt winioctl h gt include lt mcc_mcx h gt BOOLEAN Set422 HANDLE hfd MCC_CMD cmd long return_bytes int lasterror init opcode and parameters see RSMDE command in basic software or multiprotocol documentation Lif cmd Cb opcode RSMDE cmd Cb par 1 1 0 Will be replaced by channel n cmd Cb par 2 1 1 Mode RS422 active cmd Cb length 0 No data zone required if lDeviceloControl hfd IOCTL SERIAL CMD AUTO amp cmd sizeof cmd amp cmd sizeof cmd amp return_bytes NULL printf Set422 error code d n GetLastError return FALSE return TRUE PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 45 RelrpO runs the RELRP command on the board This command is not linked to a particular channel The command sends information on the board type and capabilities include lt stdio h gt include lt stdlib h
33. etCommProperties dwMaxBaud BAUD_USER because any speed supported to within 1 is accepted DwProvSubType RS232 even though these boards also support the RS422 RS485 current loop types if they have the necessary options dwMaxTxQueue dwMaxRxQueue total number of frames effectively allocated to the channel buffers Support for the other fields is standard GetCommState Returns the values specified for SetCommState except fParity SetCommState The only fields supported are BaudRate fOutxCtsFlow fOutxDsrFlow fDsrSensitivity fDtrControl fRtsControl ByteSize and Parity the last two only in some protocols GetCommTimeouts unrestricted PurgeComm unrestricted SetCommBreak The duration of the BREAK is predefined set to 1 second SetCommMask The EV_RXFLAG event is not supported For EV_RING and EV_DSR see Appendix limitations and diff rences with the COM ports page 48 SetCommTimeouts ReadIntervalTimeout is ignored except the value MAXDWORD Otherwise it should be initialised to zero to prevent any future incompatibility SetupComm No effect TransmitCommChar Not supported WaitCommEvent unrestricted EV_RXCHAR signals the arrival a complete incoming frame Driver specific services Service Comments DeviceloControl IOCTL_SERIAL_SET_SYNC_STATE Sets the protocol synchronous asynchronous synchronised asynchronous and the associated options For a full description see page 37 and for
34. he value ULONG 134 The DSR signal circuit 107 does not exist on all boards see the board connector documentation A configuration option and an API function can be used to swap the processing of this signal with RING which enables a pseudo DSR implementation if an appropriate cable is used In synchronous mode the RING signal circuit 125 is only available as from release E of the MCX BP connection package DTR in synchronous mode see the Multiprotocol software manual DT003 and the MCX_HDLC_USERDTR indicator on page 38 Supported speeds see the appropriate firmware manual DT002 DT003 PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 49 50 CONTACT ACKSYS Our sales department welcomes your enquiries about any aspect of our product range from signal converters to passive boards and will gladly offer specific technical support to help you with your own development projects Please call us on 01 39 11 62 81 in France or 33 1 39 11 62 81 from abroad Our support hotline is charge free on 01 39 11 62 81 in France or 33 1 39 11 62 81 from abroad PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002
35. if the link is disconnected or broken during the wait WriteFile is subject to the timeouts set by SetCommTimeouts SetCommMask GetCommMask W aitCommEvent The EV_MCXLAPB event the equivalent of EV_EVENTI in Win32 can be processed It is triggered each time an interrupt of the LAPB state is received see list of states below DeviceloControl IOCTL_SERIAL_SET_SYNC_STATE Sets the protocol and the associated options See the Reference Manual section DeviceloControl IOCTL_SERIAL CMD AUTO Sends a command not directly supported by the Win32 interface In particular the PRCTL command enables the state of the protocol to be checked with the ABMLINKUP ABMLINKDN and ABMSTATE options See the sample files and the detailed reference in section 41 PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 30 Driver states A LAPB channel can be in one of the 4 states shown in the diagram below DOWN COMPLETE UP FAIL P REMOTE LINK s DISC UP SUCCESS Software generated transitions honte gt Board generated transitions New state Triggered by MCX_LINK_OFF e DeviceloControl SET_SYNC_STATE switching to LAPB protocol down e DeviceloControl CMD_AUTO with PRCTL ABMLINKDN command disconnected if the disconnection occurs after the command has finished e State interrupt failure of an attempted connection by PRCTL ABMLINKUP e State interrupt disconnec
36. ikely causes are the interrupt supplying the active IRQ is not pushed in or is the wrong one the board is very busy in which case the CommandTimeout parameter value should be increased or there is a constant influx of parasites on the channel 2 In LAPB protocol a WriteFile was attempted when the link was down PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 48 997 ERROR_IO_PENDING The operation has not been completed See GetOverlappedResult 1450 ERROR NO SYSTEM _RESOURCES A DeviceloControl sent to the driver has not been recognised The likely causes are the application sends a DeviceloControl with a bad code the version of Windows NT is not supported 1784 ERROR_INVALID_USER_BUFFER In WriteFile the count parameter is too high for the size of the buffer or the frames or exceeds the 31 Kbyte limit IV APPENDIX LIMITATIONS AND DIFFERENCES WITH THE COM PORTS Several restrictions are due to the interactions between the different capabilities of the Win32 API the driver the firmware and the board itself The board s basic software limits the available flow control types see Appendix entitled Flow control above The Multiprotocol option though less effective in synchronous mode is not affected by this restriction 134 5 bauds transmission speed the DCB does not support this speed because BaudRate is a LONG variable However the driver does support this speed via t
37. len Le PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 typedef struct _MCX_SYNCHRONIZATION PARAMETERS unchar SynchronousMode protocol define MCX_SYNC_CHAR 0 NOT synchronous define MCX_SYNC_BISYNC 2 define MCX_SYNC_HDLC 4 define MCX_SYNC_LAPB 5 LAPB HDLC ABM unchar Duplex flag version 2 bits duplex define MCX WAY _ VERSION 0x80 validity bit Version field define MCX_WAY_FULLDUPLEX 0x80 full duplex version define MCX WAY HALFDUPLEX 0x81 low RTS in each frame a ieee horloges ar ETTD ETCD NULL MODEM unchar TransmitClockSource JE TXCI BRG BRG unchar ReceiveClockSource RXC BRG RXC unchar TxClockPinSource TRXC_ HIGH BRG BRG define MCX _CLOCK_RXC 0 modes for TransmitClockSource define MCX _CLOCK_TXCI 1 and ReceiveClockSource xf define MCX_CLOCK_TRXC_HIGH 0 TxClockPinSource always high define MCX _CLOCK_TXCLOCK 1 copy of TransmitClockSource define MCX_CLOCK_BRG 2 common modes define MCX_CLOCK_DPLL 3 unchar MonosyncChar unchar BisyncChar unchar Version valid if Duplex MCX_WAY McxUnshort Options dfault 0 define MCX_HDLC_USERDTR 1 slows HDLC but enables DTR define MCX _HD
38. numbered 1 2 3 and 4 on the 4P570M25 cable PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 13 PIN ASSIGNMENT OF THE 4 25 PIN MALE CONNECTORS DB25 FORMAT SIZE C ON THE 4P570M25 CABLE Signal Mnemonic Direction TxD Transmit Data Output A TxD Transmit Data Output B 3 RxD Receive Data Input A 16 RxD Receive Data Input B 24 TxClkOut Transmit Clock Output A 11 TxClkOut Transmit Clock Output B 15 TxCIkIn Transmit Clock Input A 12 TxCIkIn Transmit Clock Input B 17 RxClkIn Receive Clock Input A RxClkIn Receive Clock Input B 20 N C Not Connected 23 N C Not Connected 4 RTS Request To Send Output A 19 RTS Request To Send Output B 5 CTS Clear To Send Input A 13 CTS Clear To Send Input B 10 18 22 21 i The 5V output pin n 25 on each connector is protected by a resettable thermal fuse If an accidental short circuit occurs on the output connectors it is advisable to stop the system and identify the cause of the short circuit The system can only be powered up again after 20 seconds have elapsed PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 14 V 3 The electrical interfaces 2 EzE RS422 RS485 TxD A Vil RS485 TxClkOut B HiZ V35 Vil RS485 HiZ High impedance gt 12KQ relative to the ground The signal pairs RxD A B RxCLKIn A B and TxClkIn A B programmed in differential mode V11 or RS485 are arranged so that
39. ommProperties GetCommState SetCommState GetCommTimeouts PurgeComm SetCommBreak SetCommMask SetCommTimeouts SetupComm TransmitCommChar WaitCommEvent dwMaxBaud BAUD_USER because any speed supported to within 1 is accepted dwProvSubType RS232 even though these boards also support the RS422 RS485 current loop types if they have the necessary options dwMaxTxQueue dwMaxRxQueue total number of bytes effectively allocated to the channel buffers Support for the other fields is standard Returns the values specified for SetCommState except fParity The value RTS_CONTROL_TOGGLE for fRtsControl and the Binary and EofChar fields are not supported With the Multiprotocol options the other fields are supported normally With the basic software the driver also ignores the fields below and uses the fixed value indicated JDsrSensitivity FALSE fIXContinuesOnXoff TRUE fErrorChar FALSE JNull FALSE XonLim XoffLim 128 20 jinx fOutX fOutxDsrFlow limited support see fOutxCtsFlow fDtrControl Appendix flow control fRtsControl page 46 unrestricted unrestricted The duration of the BREAK is predefined set to 1 second For EV_ RING and EV_DSR see Appendix limitations and diff rences with the COM page 48 EV_RX80FULL does not produce the expected results and EV_RXCHAR can be 100 ms late relative to the event ReadIntervalTimeout is supported with an error of 25 100 ms Non
40. on 2 1 0 pour cartes MCC MCX MCX Lite et MCXPCI If a previous version of the program is already installed on the disk MCXSETUP checks that the version you want to install is more recent and that updating is possible before proceeding with installation It then installs the MCX SYS device driver and a number of utilities on the hard disk You will then be able to run these utilities directly from the command line prompt or from the menu bar start gt execute gt mcxsetup gt OK The first window displayed by MCXSETUP is split into two halves The first half lets you manage the driver installation process and the bottom half manages the installation and initialisation of the boards PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 18 MCXSETUP 21 installation des cartes intelligentes ACKSYS sous Windows NT COMMUNICSTIONS amp SYSTEMS bus 0 slot 10 _ non configur e d0000H irq 10 e s 280H utilisable Multiprotocole COM3 This is what the MCXSETUP v2 1 main window looks like Version indicates the version of the MCX SYS driver file that is installed on your hard disk Deinstall lets you delete MCX SYS MCXSETUP and the disk utilities and deletes the driver information from the Register PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002
41. on the main board This group of eight LEDs is numbered from DLO DLI thru DL7 Generally DLO thru DL6 are yellow and DL7 is red The purpose of these LEDs is to check that the board is operating correctly and to monitor reception transmission operations on the serial ports To interpret the status of these LEDs 3 distinct phases should be identified Phase 1 while the self test program is being run i e immediately after the board has been powered up or reset The board will display a code on the LEDs in the event of an error LED DLO DL1 DL2 DL3 DL4 DL5 DL6 DL7 Error code bit Co Cy Co C3 Ca C5 Ce C7 CO refers to the low order bit DLO which you can see printed on the circuitry The codes are as follows Code OTD sisisceiasetets ap ctircssicd nbdatecastaeaeesans CPU flag register error Code O20 cies te use ns nn CPU register error Code rhinite ARE Se BIOS memory checksum error Code DRE ue Rs tte dans DMA controllers error Cod Sheentin aa iecaamavanalese System TIMERS error COS VON Re ne RSR Error in the address test of the first 64 K or bad memory configuration Code OMS RE ee er Error in the address test of the first 64 K of E E E RAM Code OGM Ne ARE nn ne nas Error on the INT controller Code OO steel ts Unexpected INT detection Code QAR i n te cate i aol ne ee Gaels No TIMER interrupt Code OBB vicissisascaisasvaeiaisagpacnsiassseausnsvericeasteceion CPU already in protected mode Code OC LR den
42. parameters MCX_LAPB_DEFAULT will invoke the default value USHORT Protocol Lapb Spare Zone reserved for LAPB The following elements should be specified for HDLC only UCHAR Protocol Hdlc RxFrames Number of frames acceptable in reception mode without risk of loss if the PC does not read them immediately from the board number of frame receive piers on the board The value 0 resolves to the default value UCHAR Protocol Hdlc TxF rames Number of frames that the board can memorise as awaiting transmission number of frame transmit buffers on the board The WriteFile function will never halt processing if a frame buffer is available on the board at the time of the call The value 0 resolves to the default value USHORT Protocol Hdlc Spare1 Spare5 Zones reserved for HDLC The following elements should be specified for BISYNC only UCHAR Protocol Bisync RxFrames Number of frames acceptable in reception mode without risk of loss if the PC does not read them immediately from the board number of frame receive buffers on the board The value 0 resolves to the default value UCHAR Protocol Bisync TxFrames Number of frames that the board can memorise as awaiting transmission number of frame transmit buffers on the board The WriteFile function will never halt processing if a frame buffer is available on the board at the time of the call The value 0 resolves to the default value USHORT Protocol Bisync S
43. parel Spare5 Zones reserved for BISYNC 3 See the PROTO documentation in the Multiprotocol Software User Manual DT003 PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 40 IL3 Example of SET _SYNC_ STATE include lt windows h gt include lt winioctl h gt include lt mcc_mcx h gt Proto HANDLE chan int fonc MCX_SYNCHRONIZATION_PARAMETERS sp DWORD count DWORD speed switch to HDLC mode with the appropriate clocks for a NULL MODEM cable internal clocking sp SynchronousMode MCX_SYNC_HDLC sp Version 1 sp Duplex MCX_WAY_FULLDUPLEX sp Options 0 sp DataLength 0 default 1 024 bytes sp TransmitClockSource MCX_CLOCK_BRG sp ReceiveClockSource MCX_CLOCK_RXC sp TxClockPinSource MCX_CLOCK_BRG if DeviceloControl chan IOCTL_SERIAL SET SYNC STATE amp sp sizeof sp NULL 0 amp count NULL printf SET_SYNC_STATE Ioctl error d n GetLastError exit 1 PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 41 IL4 CMD and CMD AUTO functions Two communication functions have been added to enable manual dialogue with the on board interpreter For a description of the commands their parameters and data zone consult the appropriate manual for the firmware you are using basic software DTO002 or multip
44. pour votre nouveau p riph rique Cliquez sur Suivant pour rechercher les fichiers de pilote et terminer Quelle t che voulez vous que l Assistant ex cute Rechercher un pilote appropri pour mon p riph rique recommand Afficher la liste des pilotes connus pour ce p riph rique afin de pouvoir choisir un pilote sp cifique Select Next gt lt Pr c dent Suivant gt Annuler Select Next gt PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 Looking for driver files Assistant Mat riel d tect Recherche de fichiers de pilote CS O voulez vous que Windows recherche les fichiers pilotes t9 Recherche de fichiers de pilotes pour le p riph rique mat riel suivant a PCI Device L Assistant recherche les pilotes appropri s dans sa base de donn es de pilotes situ e sur votre ordinateur ainsi que dans l emplacement que vous pouvez indiquer ci dessous si vous le souhaitez Pour commencer la recherche cliquez sur Suivant Si vous effectuez la recherche sur un lecteur de disquettes ou de CD ROM ins rez la disquette ou le CD avant de cliquer sur Suivant Emplacements de recherche optionnels 17 Driver files found Assistant Mat riel d tect R sultat de la recherche de fichiers pilotes Fo L Assistant a termin la d tection des fichiers pilotes pour votre p riph rique LS mat riel Gy PCI Device Windows n a
45. pu d tecter aucun pilote pour ce p riph rique Cliquez sur Pr c dent pour effectuer une recherche dans un autre emplacement ou s lectionnez une option et cliquez sur Terminer D sactiver le p riph rique Vous pouvez utiliser l Assistant Ajout Suppression de mat riel du Panneau de configuration pour terminer l installation du pilote Ignorer l installation du pilote de ce p riph rique Windows vous demandera d effectuer l installation du pilote ult rieurement F Lecteurs de CD ROM I Emplacement sp cifique Microsoft Windows Update lt Pr c dent Terminer Enoe Arms Select Next gt Select End Next time you reboot the computer Windows will no longer ask these questions if you have selected Disable device in the last step When you have completed this dialogue proceed with driver installation VI 2 Installation and configuration When you have installed the board in the computer and restarted the operating system place the MCC MCX MCX Lite Windows NT Driver amp utilities diskette in drive A and execute the command A SETUP This script starts the installation and configuration program called MCXSETUP The first time you execute the program it will detect that the MCX SYS driver has not yet been installed and ask you to confirm the installation Installation mise a jour du pilote Q Voulez vous proc der l installation du pilote Acksys versi
46. rotocol software DT003 include windows h include winioctl h include mecc_mex h DeviceloControl Device IOCTL_SERIAL_CMD paramsFromAppToBoard paramsToSize paramsFromBoardToApp paramsFromSize lpcbBytesReturned lpoOverlapped DeviceloControl Device IOCTL_SERIAL_CMD_AUTO paramsFromAppToBoard paramsAppSize paramsFromBoardToApp paramsBoardSize lpcbBytesReturned lpoOverlapped HANDLE hDevice Handle of the device PMCC_CMD paramsFromAppToBoard pointer to sent parameters DWORD paramsAppSize size of sent params PMCC_CMD paramsFromBoardToApp pointer to returned parameters DWORD paramsBoardSize size of space for returned params LPDWORD pcbBytesReturned size of returned params LPOVERLAPPED poOverlapped overlapped struct addr The IOCTL_SERIAL_CMD function can make the board execute any command The IOCTL_SERIAL_CMD_AUTO function can make the board execute any command with parameter 1 being initialised by the driver and the channel number corresponding to hDevice The MCC_CMD type is a structure that matches that of the board s mailbox This enables the application to transmit and receive parameters and data When a command is sent to the board by these functions the driver executes one of the following actions 1 If it exists the paramsFromAppToBoard Data table is copied into the DATA zone of the board s mailbox 2 the params FromAppToBoard Cb par
47. standard buffer sizes are ignored An error may be indicated in some cases see the section on the configuration of advanced properties page 15 The standard sizes are 8 192 characters per channel for transmit buffers and 512 characters per channel for receive buffers Not supported unrestricted PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 21 I 2 Programming synchronous communications For general information consult Microsoft s Win32 communications documentation The information below simply discusses cases where the Win32 serial communication API is inappropriate cases where the driver differs from the Win32 specifications cases in which the Win32 documentation is vague File services Service CreateFile ReadFile WriteFile CloseHandle FlushFileBuffers Comments after CreateFile the transmit and receive buffers are empty ReadFile always returns a maximum of one frame If the frame exceeds the requested length only the first part will be returned and the rest lost If the frame is shorter than the requested length it is returned in full and the requested buffer is not completely filled even if another frame is already present in the board buffer it will be provided with the next ReadFile If the frame contains an error ABORT CRC etc ReadFile returns an error see also the compatibility options in the section on installation each WriteFile creates a
48. t aire se Error in DMA page register Code ODE set en eee dater aid No memory refresh Code Obs re kee eis Error on keyboard controller Code QFhi sissien finit Cannot enter protected mode Code WO Mics hala n ai Error on GDT or IDT registers Code IE ees iasta a ae s Error on LDT register PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 Code hi a entree Error in task register Code 3b zie pene ates dae dels Error on LSL instruction Ode MA cei fae e esas tion eam gen S ES Error on LAR instruction Code TST sentier run ne Error on VERR VERW Code TOarsesnise enmadilans us iert Error on A20 address line Code L7h sessions Unexpected exception Code 1 Sit n cree Morse Shutdown during memory test Code VOM RP EEE Copyright checksum error Code IAN 2250 eek tee Parameter checksum error Code COR sisietisedeis aneen n an Error in memory test Code Class rnb ss ss pas Error on IO CHECK signal ODE Chr ns a Watchdog time out Code CAES anse nl nn er Bus time out Code Slh552 otitis An tes Error on UART SCC or SCA Code SM ins es se nee ne Dual access memory error CO SR St See nn AN E Unexpected TRAP error Code 84h sismianilninnumeddes Buffer error CodeS INe nn Ass cn ee Firmware checksum error CCE BOB csie tung Lithium battery error Code STE En nn ee nn MCXPCI to PC interrupt error Code Bh acensas rinii aa Watchdog error Code 89 Sarietan a e a e ee FIFO flags or
49. table is copied into the mailbox s PARAMETERS zone 3 paramsFromAppToBoard Cb opcode is copied into the mailbox s OPCODE zone 4 the binary value 0000 0001 is written into the mailbox s VALIDATION byte This causes the board to execute the command The board then issues an end of command interrupt that enables the driver to continue processing 5 the mailbox s STATUS zone is copied into paramsFromBoardToApp Cb status PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 42 6 the PARAMETERS zone in the mailbox is copied into paramsFromBoardToApp Cb par 7 if the paramsFromAppToBoard Data existe table exists the mailbox s DATA zone is copied into paramsFromBoardToApp Data 8 the application is woken up or alerted depending on the poOverlapped value The length of the MCC_CMD Darta field is variable For example the structure can be created by dynamically allocating sizeof MCC_CMD data_length bytes the MCX_DIRECT_IO_BUFFER_SIZE datalen macro can be used to calculate the required number of bytes The driver recognises the existence of the Data field if the Cb length field is non null Otherwise it assumes that the command that is to be executed does not use the mailbox s DATA zone paramsAppSize must be equal to the sum of sizeof MCC_CMD and the length of the data zone If the command has been executed correctly the integer designated by pchBytesReturned will still equal paramsBoard
50. ted The overall configuration procedure is consequently as follows 1 Find the line that corresponds to the board you want to configure If several boards have been installed they can be identified by their bus and slot numbers 2 Double click on the board to open the properties window 3 Select the model from the list of boards 4 Select multiprotocol mode 5 Select the other parameters according to your needs and click on OK to close the properties window 6 Reselect the board in the list and click on Test PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 20 VI 4 Board properties These parameters modify the operation of the device driver They are only analysed each time the driver is restarted The driver can be restarted either when the system is rebooted or manually from the Devices icon in the Windows Control Panel or at the command line prompt by entering the net stop mcx command followed by net start mcx or by MCXSETUP with user confirmation Use the General tab to specify the characteristics of the board you want to install Propri t s de la carte intelligente ACKSYS E Logiciel de base Mx xl Looiciel de base x ESS Ps2 2 General properties of an MCX MCXPCI or MCX Lite board Inhibit driver for this board Checking this box will prevent the driver from accessing the board described You c
51. the PC releasing the bandwidth of the PCI bus for the exchange of useful information between the PC and the board Running on Windows NT 4 0 and Windows 2000 systems an ACKSYS driver can make use of the board s 4 intelligent serial ports in compliance with the specifications of the Windows Win32 API Files COMM amp Ioctl the market standard for traditional PC serial ports PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 II OPERATIONAL RESTRICTIONS Number of boards eeeeeeeeeeeseeeeeeees limited to the number of available slots Operating SYST ME ant Windows NT 4 0 from SP3 upwards and Windows 2000 Monoprocessor only Firmware MCX Multiprotocol Version 3 1 or later Buses supported 5 5 00clseiccssntcanesdececacaseseces PCI amp CPCI 5V Max bitrate in ASYNC mode 250 Kbps Max bitrate in ASYNC sync mode 250 Kbps Max bitrate in MONOSYNC mode 4 Mbps Max bitrate in BISYNC mode 4 Mbps Max bitrate in raw HDLC mode 4 Mbps Max bitrate in HDLC ABM mode 4 Mbps Ill SUPPORTED PROTOCOLS AN OVERVIEW This is a quick overview of the protocols supported by the board For full information on these protocols consult the documentation on the MCX Multiprotocol firmware The synchronous protocols support the FMO FM1 NRZi amp NRZ encoding modes see the VINIT command in the MCX MULTIPROTOCOL firmware Th
52. the envelope of the HDLC frame In transmission mode the board encapsulates the outgoing data buffer used by the WriteFile function in an HDLC frame Flag Ox7E OUTGOING DATA CRC CCITT PRESET 1 Flag 0x7E The PC sends only the outgoing data block to the board which handles the calculation and generation of the CRC the management of the stuffing bit and the generation of the frame start and end flags In reception mode if the board receives a frame of the following type Flag Ox7E INCOMING DATA CRC CCITT PRESET 1 Flag 0x7E The board takes full control of the frame CRC ABORT OVERRUN FRAMING ERROR handles the stuffing bit and only sends the incoming data block to the PC buffer used by the ReadFile function ILS HDLC ABM or LAPB mode HDLC ABM is a mode in which the board manages level 2 of the HDLC procedure in ABM mode The distinctive characteristics of this protocol are The general frame format is that described above for RAW HDLC mode Unnumbered frames SABM UA DM Supervision frames RR REJ RNR Information frame I TI timeout N 2 retry count Max frame length N1 Width of the K sliding window modulo 8 P Fbit The PC only manages the buffers for data carried in the I information frames and the connection disconnection of the communication link The stuffing bit is a mechanism that is specific to the HDLC protocol that prevents the possible oc
53. tion following a fatal transmission error e State interrupt successful disconnection request by PRCTL ABMLINKDN MCX_LINK_GO_UP e DeviceloControl CMD_AUTO with PRCTL ABMLINKUP command connection in e State interrupt temporary disruption following a recoverable error progress MCX_LINK_ON e DeviceloControl CMD_AUTO with PRCTL ABMLINKUP command up connected if the connection occurs before the end of the command e State interrupt reception of a request or acknowledgement of a connection MCX_LINK_GO_DN e DeviceloControl CMD_AUTO with PRCTL ABMLINKDN command break in progress PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 31 Effect of state changes No action is taken when the state change is caused by the application The table below summarises the action taken when a state change is interrupted New state Action MCX LINK OFF EV_MCXLAPB signalled if specified by an earlier SetCommMask 7 g Any ReadFile will return 0 characters and the ERROR_HANDLE_EOF error Any WriteFile will return the ERROR_NOT_READY error MCX_LINK_ON EV_MCXLAPB signalled if specified by an earlier SetCommMask Current status information There are three ways to obtain information on the state of the connection E The first imprecise consists of assuming that the PRCTL ABMLINKUP command always switches to the MCX_LINK_ON state that PRCTL ABMLINKDN always switches to the MCX_LINK_OFF state and detecting any dis
54. use the command see the program sources a winnt sdk msvc utils mccioctl c and a winnt sdk msvc special addfunc c PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 32 I 5 Standard Windows NT utilities If you just want to use the standard Windows NT utilities with your MCX boards it is advisable to select the name COM in the installation procedure Control panel Do not use the ports icon to create the COM channels for MCX boards because the driver creates these names automatically However you can use this dialogue to change the transmission parameters this is useful if a channel is used by the Print Manager Moreover you should not try to use this dialogue to define addresses or interrupts HyperTerminal exe This Windows NT 4 accessory works normally with this driver Terminal exe This Windows NT 3 x accessory only supports the COM1 thru COM9 ports Mode exe This DOS utility only supports the names that begin with COM and in Windows NT 3 1 only COMI thru COM9 It can only be used to modify asynchronous transmission modes Our mexmode exe utility can be used to work around these restrictions see the description of mcxmode exe Remote Access Services This communication system has been successfully tested from version 1 6 3 of the driver upwards in single channel server mode on Windows NT 3 51 Workstation The Windows NT 4 0 dialling interface does not work with this driver
55. vsuescdcesvescocesssscecvavescdceseedesceseds coconcsSeosesesseseeses 34 IL2 SET GET SYNC STATE functions suisses 37 II 3 Example of SET_SYNC_STATE sise 40 II 4 CMD and CMD AUTO functions srerrseirreorrerisrorreisieer rr rrt tobrt nene E EErEE ES rE REECE REEE EEDE REESE EEEN renier enk 41 II 5 Samples of CMD and CMD_AUTO sieniniai einai i aii aia 44 M APPENDIX SPECIFIC ERROR CODES ed nn 47 IV APPENDIX LIMITATIONS AND DIFFERENCES WITH THE COM PORTS 48 ANNEXES PCI WAN HDLC RANGE WINDOWS NT 4 0 AND 2000 USER MANUAL REV A 1 APRIL 2002 CONTACT ACKS YS nn eee inner hes 50 I PRESENTATION This manual describes the technical characteristics of the boards in the ACKSYS WANHDLC range and explains how they are integrated and used with the Windows NT and Windows 2000 operating systems The boards in the WAN HDLC range extend the communication capabilities of a PC PCI or CPCI 6U by adding serial communication interfaces that are multiprotocol asynchronous synchronised asynchronous Monosync Bisync Raw HDLC amp HDLC ABM and multi interface RS232 V28 RS422 V11 RS485 amp V35 Each board has 4 fully independent channels of this type A typical configuration might be Channel 1 Raw HDLC RS422 Channel 2 ASYNC synchronised RS232 Channel 3 HDLC ABM V35 Channel 4 MONOSYNC RS485 These boards offload communication line management tasks such as acquisition transmission and protocol from