Home
GE Vivid™ T8 Spec Sheet
Contents
1. Part 1 Evaluation and testing EN 62366 Medical devices Application of usability engineering to medical devices Inputs and Outputs Composite color video output S Video output VGA output SXGA resolution Audio stereo output 100BASE TX ethernet RJ45 USB 3x in rear 3 under keyboard Virus Protection To reduce virus vulnerability Vivid T8 is configured with a minimal set of open ports and with all network services not actively used by the system closed down This helps to reduce the risk of a virus attack on Vivid T8 GE is continuously judging the need for additional actions to reduce vulnerability of equipment this includes vulnerability scanning of our products and evaluation of new security patches for the third party technology used Microsoft and other security patches that address serious issues with Vivid T8 will be made available to customers after GE verification of those patches Transducers 3Sc RS Phased Array Sector Probe e Applications Cardiac Cardiac_2 Abdominal Renal Cranial Exercise Pediatric LVO Contrast FAST FATE e Biopsy Guide Multi angle reusable bracket 6S RS Phased Array Probe e Applications Pediatric Pediatric_2 Coronary Neonatal Head Fetal Heart Abdominal Pediatric Abdominal L6 12 RS Linear Array Probe e Applications Carotid Thyroid Breast LEA LEV UEA UEV Musculoskeletal Musculoskeletal Superficial Small Parts Scrotal Pediatric Abdomen Ped
2. CW Pencil Endovaginal TEE Operating Modes 2D tissue 2D color flow 2D angio flow Color M mode Tissue velocity M mode Continuous wave Doppler Tissue M mode Pulsed wave Doppler with high PRF Anatomical M mode Curved anatomical M mode optional Tissue velocity imaging Tissue tracking optional Tissue synchronization imaging optional Strain imaging optional Strain rate imaging optional Tissue Doppler imaging Blood flow imaging optional Blood flow angio flow imaging optional Smart Stress optional Auto EF optional AFI Automated Function Imaging optional Coded phase inversion LVO contrast optional Compound imaging Scan assist optional Image archive Z scores Fetal trending Renal calculations On board report package MPEGVue optional System Options e Curved AMM Blood flow imaging Blood flow imaging with Angio B flow Tissue tracking e TSI Strain imaging Strain rate imaging Smart Stress optional e AFI Auto EF Q Analysis LOGIQView Scan Assist e IMT DICOM connectivity MpegVue eVue LVO contrast Extra probe holder Paper tray Probe cable tray Flexible arm Peripheral Options e LITEON eUAU108 DVDRW e UP D711MD e SONY UPD25 color printer e B W printer UP D897MD e HP 100 printer 8GB memory stick e 17TB USB hard drive e Three pedal configurable footswitch e ECG kits Display Modes e Live and stored display format Ful
3. Optional on board storage for thermal printer integrated speakers Integrated locking mechanism that provides rolling lock and caster swivel lock Integrated cable management Removable air filters Front and rear handles Optional probe cable tray One integrated gel holder Six probe holders two optional four standard User Interface Operator Keyboard e Support for international keyboard character sets e Ergonomic full size hard key layout e Interactive back lighting for control panel e Six TGC pods Touch Screen e 8 4 high resolution color touch screen e Interactive dynamic software menu LCD Monitor 19 high resolution LCD Optional articulating monitor arm Optional LCD translation 25 90 tilt on LCD Swivel to side viewing direction Fold down and rotation lock mechanism for transportation Resolution 1280 x 1024 Brightness contrast adjustments System Overview Applications probe dependent Abdominal Cardiac adult and pediatric Musculo skeletal conventional and superficial Small Organ Pediatric Obstetrics Gyn Fetal heart and body Transesophageal Peripheral Vascular Transvaginal Transrectal Adult and Neonatal Cephalic Scanning Methods e Electronic sector e Electronic convex e Electronic linear e CW pencil Vivid T8 product datasheet April 2014 DOC1509022 Page 1 of 10 Transducer Types Sector phased array Convex array Linear array
4. e Multi variate color priority function gives delineation of disturbed flows even across bright areas of the 2D mode image e Color Doppler frequency can be changed independently from 2D Color Flow Imaging e TruSpeed imaging allows either ultra high frame rate or increased lateral resolution as compared to previous generation GE products e Frame Rate in excess of 150 fps depending on probe and settings e Variable ROI size in width and depth e User selectable radial and lateral averaging to help reduce statistical uncertainty in the color velocity and variance estimates e Data Dependent Processing DDP performs temporal processing and display smoothing to help reduce loss of transient events of hemodynamic significance e Digital replay for retrospective review or automatic looping of color images allowing for adjustment of parameters such as DDP encoding principle baseline shift color maps color priority and color gain even on frozen recalled data e Application dependent multi variate motion discriminator reduces flash artifacts e Application dependent multi variate motion discriminator helps reduce flash artifacts e Dedicated coronary flow application Color Angio e Angle independent mode for visualization of small vessels with enhanced sensitivity compared to standard color flow of previous GE products Vivid T8 product datasheet April 2014 DOC1509022 Page 5 of 10 Color M mode Varia
5. in background during regular 2D imaging The velocity of myocardial segments after entire heart cycle can be displayed in one single image Tissue color overlay can be removed to show just the 2D image still retain ing the tissue velocity information Quantitative profiles for TVI tissue tracking strain and strain rate can be derived Time markers for valve events derived from any TM mode help simplify understanding of signals in velocity traces or curved anatomical M mode Tissue Tracking Mode optional Real time display of the time integral of TVI for quantitative display of myocardial systolic displacement Myocardial displacement is calculated and displayed as a color coded overlay on the grayscale and M mode image different colors represent different displacement ranges Tissue Synchronization Imaging Mode optional e Parametric imaging which gives information about synchronicity of myocardial motion Myocardial segments colored according to time to peak velocity green for early and red for late peak Waveform trace available to obtain quantitative time to peak measurement from TSI Image Available in live scanning as well as an offline calculation derived from tissue Doppler data Additional features in combination with multi dimensional imaging option Simultaneous acquisition of tri plane TSI images covering all standard segments in apical views Efficient segment specific TSI time measur
6. Vivid T8 Product Description The Vivid T8 is our Multipurpose Cardiovascular System designed for reliability in busy environments for cardiac and shared service imaging with the additional capabilities of 2D adult pediatric fetal obstetrics vas cular peripheral vascular urological abdominal transcranial small parts musculoskeletal and transesophageal applications System Architecture Ease of Use features help make the Vivid T8 a productive cardiovascular ultrasound system simplification of Vivid software and touch panel help make working seamless in any environ ment Stress Echo Auto EF and Scan assist help allow for a productive environment with added efficiency True Scan Raw Data is GE s innovative technology that allows for advanced processing on archived images by applying many of the same scan con trols and advanced quantitative tools available during the original exam General Specifications Dimensions and Weight e Width Keyboard 500 mm 19 7 in Caster 720 mm 28 3 in e Depth Maximum 810 mm 31 9 in Caster 800 mm 31 5 in e Height Maximum 1495 mm 58 9 in Minimum 1410 mm 55 5 in e Weight 58 kg 128 Ibs Electrical Power e Nominal input voltage 100 240 VAC frequency 50 60 Hz e Power consumption maximum 400 VA with peripherals Console Design Four active probe ports ECG port Integrated HDD 500G Multiple USB ports Optional DVD RW drive
7. ble ROI length and position user selectable User selectable radial averaging to help reduce statistical uncertainty in the color velocity and variance estimates Selectable horizontal scroll speed 1 2 3 4 6 8 12 16 seconds across display can be adjusted during live digital replay or image clipboard recall Real time 2D image while in color M mode Same controls and functions available as in standard 2D color Doppler Anatomical Color M mode e GE patented any plane color M mode display derived from color Doppler cine loop e Also applicable to tissue velocity imaging e M amp A capability B flow optional B flow is a digital imaging technique that provides real time visualization of vascular hemodynamics by directly visualizing blood reflectors and presenting this information in a grayscale display Use of GE patented techniques to boost blood echoes and to help preferentially suppress non moving tissue signals B flow is available for most vascular and shared service applications Blood Flow Imaging optional e Combines color Doppler with grayscale speckle imaging e Helps improve delineation of blood flow without bleeding into tissue or vessel wall Blood Flow Angio Imaging optional e Combines angio with grayscale speckle imaging Tissue Velocity Imaging Tissue Velocity Imaging Mode e Myocardial Doppler imaging with color overlay on tissue image Tissue Doppler data can be acquired
8. ction Fraction Calc e Automated EF measurement tool based on 2D speckle tracking algorithm e Integrated into M amp A package with worksheet summary Annotations Body Marks e Body mark icons for location and position of probe e Easy selection of body marks from touch panel Text Annotations e Easy selection of text annotations from touch panel Scan Assist optional e Customizable automations that assist the user through each step of the scan e Helps enhance consistency and reduce keystrokes e Supports selection of all modes all measurements and dual annotations e Imaging attributes Octave Steer Dual Quad screen Compound LOGIQView Zoom Depth Scale and Baseline e On line or off line protocol editor e Image acquisition according to predefined protocol templates e Various factory protocol templates e User configurable protocol templates e Wall motion scoring Analysis by wall motion in individual myocardial segments Supported Protocol Examinations e 2D pharmacological stress echo e 2D bicycle stress echo e 2D continuous capture stress echo treadmill stress echo e Q Stress protocols acquire tissue velocity data in background for quantitative analysis e Cardiac resynchronization therapy programming protocols Protocol Examinations May Include e Show reference Show a reference image from baseline or previous level during acquisition e Smart stress Automatically set up various
9. d TGC curves helps reduce operator interaction Automatically calculated lateral gain 2D Mode Sector tilt and width control Frame rate in excess of 1 000 fps depending on probe settings and applications Coded octave imaging with coded phase inversion GE 3rd generation harmonic tissue imaging providing enhanced lateral and contrast resolution as compared to previous generation GE products Features help reduce noise help improve wall definition and axial resolution making it well suited for a wide variety of patient groups Confocal imaging allows for multiple transmit focal zones over range of view and a high vector density probes dependent Automatic tissue optimization single keystroke optimizes immediately and automatically different grayscale settings adjusted for the real time image UD Clarity and UD Speckle reduce imaging an advanced image processing technique to help reduce speckle in real time examining the relative difference between neigh boring pixel values and determining whether the grayscale variations have a sharp difference follow a trend or are random in nature Variable image width a reduction either increases frame rate or increases the number of focal zones while maintaining the frame rate application dependent Vivid T8 product datasheet April 2014 DOC1509022 Page 4 of 10 e Multiple angle compound imaging multiple co planar images from different angles combined in
10. d for imaging of the left ventricle 1 Schering developed harmonic imaging for supporting contrast agent imaging LV contrast 3Sc RS enhances delinea tion of the LV border in combination with ultrasound contrast agents The new implementation of GE s Coded Phase Inversion CPI provides high resolution detection of contrast in the LV cavity and excellent suppression of myocardial tissue signals Physiological Traces e Integrated ECG or external ECG lead input e High resolution display of the ECG trace e User adjustable trace gain position and trace invert controls e User pre settable trace gain position control e Automatic QRS complex detection with user ability to modify QRS trigger positions Automatic Optimization e Optimize B mode image to help improve contrast resolution gain TGC and grayscale e Auto spectral optimize adjustments baseline PRF Seamless data storage and report creation User assignable parameters Comprehensive set of cardiac measurements and calculations to help assess dimensions flow properties and other functional parameters of the heart Comprehensive set of shared service measurements and calculations cover ing vascular abdominal obstetrics and other application areas Configuration package to set up a customized set and sequence of measurements to use defining user defined measurements and changing settings for the factory defined measurements Vivid stress ech
11. ed on CD with each system A printed manual is available upon request CINE Memory Image Memory 210 MB of cine memory Selectable cine sequence for cine review Measurements calculations and annotations on cine playback Scrolling timeline memory Dual image cine display Quad image cine display CINE gauge and cine image number display CINE review loop CINE review speed Image Storage e On board database of patient information from past exams Storage formats DICOM compressed uncompressed single multi frame with without raw data Save As JPEG MPEG AVI Storage devices USB memory stick 8 GB CD RW storage 700 MB DVD storage R 4 7 GB Hard drive storage 500 GB Compare old images with current exam Reload of archived data sets Connectivity and DICOM e Ethernet network connection DICOM Verify Print S Store Modality worklist torage commitment Modality Performed Procedure Step MPPS Media exchange Off network DICOM spooler Query Retrieve Structured reporting compatible with adult cardiac and vascular Media store of structured reporting InSite ExC capability for remote service access EchoPAC Connectivity e Connectivity and image review capability of Vivid T8 from EchoPAC PC e EchoPAC PC allows instant access to ultrasound images provided by the system e Three user levels help organize data security requirements Vivid T8 product datashee
12. ements Immediate bull s eye report Automatic calculated TSI synchrony indexes TSI surface mapping LV synchronization report template CRT programming protocol Strain Strain Rate Mode optional Tissue deformation and rate of deformation are calculated and displayed as real time color coded overlay on the 2D image Tissue deformation strain is calculated and displayed as real time color coded overlay on the 2D Image Cine compound calculates and displays cineloops generated from a temporal averaging of multiple consecutive heart cycles Anatomical M mode and curved anatomical M mode displays Sl and SRI Spectral Doppler General Operates in PW HPRF and CW modes Trackball steerable Doppler available with all imaging probes max steering angle is probe dependent Selectable Doppler frequency for enhanced optimization High quality real time duplex or triplex operation in all Doppler modes in PW and for all velocity settings Frame rate control for optimized use of acquisition power between spectrum 2D and color Doppler modes in duplex or triplex modes Very fast and flexible spectrum analysis with an equivalent DFT rate of 0 2 ms Dynamic gain compensation for display of flows with varying signal strengths over the cardiac cycle to help improve ease of use Vivid T8 product datasheet April 2014 DOC1509022 Page 6 of 10 Dynamic reject gives consistent suppression of background use
13. growth charts e Growth percentiles e Multi gestational calculations up to four e Programmable OB tables e Expanded worksheets e User selectable fetal growth parameters based on European American or Asian methods charts e GYN package for ovary and uterus measurements and reporting e Please refer to the user manual for the full list of measurements and calculations for all applications Quantitative Analysis Package Q Analysis optional e Traces for velocity or derived parameters strain rate strain displacement inside defined regions of interest as function of time e Contrast analysis with traces for grayscale intensity or angio power inside defined regions of interest as function of time including post processing ECG triggering and curve fitting for wash in wash out analysis e Curved anatomical M mode display allowing an M mode along an arbitrary curve in a 2D image Automated Function Imaging AFI optional e Parametric imaging tool which gives quantitative data for global and segmental wall motion e Allows comprehensive assessment at a glance by combining three longitudinal views into one comprehensive bull s eye view e Integrated into M amp A package with specialized report templates e 2D strain based data moves into clinical practice e Simplified workflow with fully auto mated ROI tracings if configured quick tips and combined display of traces from all segments Automated Eje
14. iatric Hip Neonatal Abdomen Neonatal Hip e Biopsy guide Multi angle disposable with a reusable bracket 4C RS Curved Array Probe e Applications Abdomen Abdomen 2 Follicle GYN OB1 OB23 Pediatric Abdominal Prostate Renal e Biopsy guide Multi angle disposable with a reusable bracket PROBE FREQUENCY RANGE 3Sc RS 1 3 4 0 MHz 6S RS 2 7 8 0 MHz L6 12 RS 6 0 13 0 MHz 4C RS 1 8 6 0 MHz 8C RS 4 0 11 0 MHz E8C RS 4 0 11 0 MHz 6Tc RS 2 9 8 0 MHz P2D 2 0 MHz 8C RS Micro Convex Probe Applications Pediatric Abdominal Pediatric Hip Neonatal Abdominal Neonatal Head Vascular Biopsy Guide Not available E8C RS Endo Micro Convex Probe e Applications Fetal Echo Follicle GYN OB1 Prostate e Biopsy Guide Fixed angle disposable or reusable bracket 6Tc RS TEE Probe e Applications Cardiac Cardiac_2 Coronary P2D Pencil Probe e Applications Cardiac CATALOG H45041DL H45021RP H48062AC H4000SR H40402LS H40402LN H45551ZE H45551CA Vivid T8 product datasheet April 2014 DOC1509022 Page 9 of 10 2014 General Electric Company All rights reserved April 2014 General Electric Company reserves the right to make changes in specifications and features shown herein or discontinue the product described at any time without notice or obligation Contact your GE representative for the most current information GE GE Monogram Vivid InSite and EchoPAC are trademarks of Gene
15. l size and split screen both with thumbnails for still and cine e Review image format 4 x 3 and thumbnails for still and cine Simultaneous capability B PW B CFM TVI PW B CFM TVI B CFM Angio TVI SRI TT SI TSI B M AMM CAMM B CFM Angio TVI SRI TT SI TSI M AMM CAMM Real time duplex or triplex mode Compound M CFM PW B color split screen simultaneous mode Selectable alternating modes Bor compound PW B CW Bor compound CFM PW B CFM CW Multi image split quad screen Live and or frozen Independent cine playback Timeline display Independent B or compound PW CW M display Display formats Top bottom selectable format Display Annotation Patient name First last and middle Patient ID Age sex and birth date Hospital name Date format Two types selectable MM DD YY DD MM YY Time format Two types selectable 24 hours 12 hours Gestational age from LMP EDD GA Probe name Map names Probe orientation Depth scale marker Focal zone markers mage depth Zoom depth Vivid T8 product datasheet April 2014 DOC1509022 Page 2 of 10 B mode Gain Dynamic range Imaging frequency Frame averaging Gray map Speckle reduction imaging UD clarity M mode Gain Dynamic range Time scale Doppler mode Gain Angle Sample volume size and position Wall filter Velocity and or frequency scale Spectrum inversion Ti
16. ll speed 1 2 3 4 6 8 12 16 seconds across display e Horizontal scroll can be adjusted in live or digital replay Anatomical M mode e M mode cursor can be adjusted at any plane e Curved anatomical M mode free curved drawing of M mode generated from the cursor independent from the axial plane e Can be activated from live digital replay or image clipboard recall e Anatomical color and tissue velocity M mode e M amp A capability Color Doppler Imaging General e Steerable color Doppler available with all imaging probes max steering angle is probe dependent e Trackball controlled ROI e Removal of color map from the tissue during digital replay e Digital replay for retrospective review of color or color M mode data allowing for adjustment of parameters such as encoding principle color priority and color gain even on stored data e PRF settings user selectable e Advanced regression wall filter gives efficient suppression of wall clutter e For each encoding principle multiple color maps can be selected in live and digital replay variance maps available e More than 65 000 simultaneous colors processed providing a smooth display two dimensional color maps containing a multitude of color hues e Simultaneous display of grayscale 2D and 2D with color flow e Color invert user selectable in live and digital replay e Variable color baseline user selectable in live and digital replay
17. me scale PRF Doppler frequency Color flow Doppler mode Frame rate Frame averaging Sample volume size Color scale Power Color baseline Color threshold marker Color gain PDI Spectrum inversion Doppler Acoustic frame rate CINE indicator image number frame number Bodymarks Multiple human and animal types Application name Measurement results Operator message Displayed acoustic output TIS Thermal Index Soft Tissue TIC Thermal Index Cranial Bone TIB Thermal Index Bone MI Mechanical Index Power output in dB Biopsy guide line and zone Heart rate Trackball driven annotation arrows Active mode display Stress protocol parameters Parameter annotation follow ASE standard Free text with work library General System Parameters System Setup Pre programmable categories User programmable preset capability with administrator preset protection Factory default preset data Languages English French German Spanish Italian Portuguese Swedish Danish Dutch Norwegian Japanese Chinese Polish Finnish Greek Russian Hungarian Slovak Romanian Czech Latvian Lithuanian Turkish Estonian Korean Serbian Bulgarian Croatian Indonesian Slovenian User defined annotations Body patterns Customized comment home position Comprehensive User Manual Available on Board Available through touch panel utility page User manual and service manual are includ
18. o support allowing wall motion scoring and automatic stress level labeling of measurements Support for measuring on DICOM images Automatic Doppler trace functionality for use in non cardiac applications in both live and replay Worksheet for review edit and deletion of performed measurements Reporting support allowing a configurable set of measurements to be shown in the exam report DICOM SR export of measurement data on live image and angle correction Measurement and Analysis M amp A Cardiac calculation package including extensive measurements and display of multiple repeated measurements Vascular measurements package Measurements can be labeled seamlessly by using protocols or post assignments Measurements assignable to protocol capability Parameter annotation follow ASE standard Intima Media Thickness IMT Measurements optional e Automated measurement of IMT rather than measuring the IMT manually e Results representative of a region rather than a single point of a vessel wall e Help reduce examination time by enhancing the procedure in measuring the IMT Z Scores e Limited implementation of z scores for a set of predefined pediatric dimension measurements Vivid T8 product datasheet April 2014 DOC1509022 Page 7 of 10 OB GYN Application Module e OB package for fetal growth analysis containing more than 100 biometry tables e Dedicated OB GYN reports e Fetal graphical
19. r selectable in real time digital replay or image clipboard recall Digital replay for retrospective review of spectral Doppler data Several top bottom formats side by side format and time motion only format can be adjusted in live or digital replay Selectable horizontal scroll speed 1 2 3 4 5 6 8 12 seconds across display can be adjusted in live or digital replay Adjustable spectral Doppler display parameters Gain reject compress color maps can be adjusted in live or digital replay User adjustable baseline shift in live digital replay and image clipboard recall Adjustable velocity scale Angle correction with automatic adjustment of velocity scale in live digital replay and image clipboard recall Stereo speakers mounted in the front panel Display annotations of frequency mode scales Nyquist limit wall filter setting angle correction acoustic power indices Compound in duplex PW HPRF Doppler Automatic HPRF Doppler maintains its sensitivity even for shallow depths and with high PRF s Digital velocity tracking Doppler employs processing in range and time for high quality spectral displays Adjustable sample volume size of 1 8 mm probe dependent Maximum sample volume depth 30 cm CW Doppler Highly sensitive steerable CW available with all phased array probes Tissue Velocity Doppler Contrast Imaging optional LVO Contrast Enables contrast applications intende
20. ral Electric Company or one of its subsidiaries Third party trademarks are the property of their respective owners DICOM is a trademark of the National Electrical Manufacturers Association Microsoft and Excel are trademarks of Microsoft Corporation HP is a trademark of 2014 Hewlett Packard Development Company L P LITEON is a trademark of Lite On IT Corporation SONY is a trademark of Sony Corporation GE Medical Systems Ultrasound amp Primary Care Diagnostics LLC a General Electric Company doing business as GE Healthcare About GE Healthcare GE Healthcare provides transformational medical technologies and services to meet the demand for increased access enhanced quality and more affordable healthcare around the world GE NYSE GE works on things that matter great people and technologies taking on tough challenges From medical imaging software amp IT patient monitoring and diagnostics to drug discovery biopharmaceutical manufacturing technologies and performance improvement solutions GE Healthcare helps medical professionals deliver great healthcare to their patients Distributed By GE Healthcare 9900 Innovation Drive Wauwatosa WI 53226 U S A Ly NN MEDICAL At the Heart of Innovative Technology Solutions Contact us today to place an order Phone 888 LynnMed 888 596 6633 www gehealthcare com imagination at work Fax 248 560 0500 www lynnmed com DOC1509022
21. recalled images and loops DICOM media read write images on DICOM format Alphanumeric data can be exported in Microsoft Excel compatible format JPEG export for still frames AVI and MPEG export for cineloops eVue MPEGvue Allows interactive viewing of images loops or full exams from remote location Using MPEGvue exams may be stored onto removable media or on remote networked system together with integrated MPEGvue player for viewing on standard PC Scanning Parameters Digital beamformer with up to 193 536 effective digital channels Displayed imaging depth 0 30 cm probe dependent Minimum depth of field 0 2 cm probe dependent Maximum depth of field 0 33 cm probe dependent Continuous dynamic receive focus continuous dynamic receive aperture Adjustable dynamic range up to 120 dB Image reverse Right left Image rotation of 0 180 Tissue Imaging General Variable transmit frequencies for resolution penetration optimization Display zoom with zoom area control High Resolution HR Zoom concentrates all image acquisition power into selected Region of Interest ROI Variable contour filtering for edge enhancement Depth range up to 30 cm probe specific Selectable grayscale parameters availability preset dependent Gain reject DDP clarity dynamic range and compress can be adjusted in live digital replay and image clipboard recall Automatically calculate
22. scanning parameters for instance geometry frequency gain etc according to same projection on previous level e Scan mode settings Scan mode may be specified for individual views in the protocol e Preview of store Show running loops as preview before storing to the examination Continuous Capture e Continuously acquire large amounts of 2D image data and selection of projection views for analysis afterwards e The entire continuous capture recording may be kept in memory while it is possible to store new images outside the protocol template or the entire recording can be stored to file e Selection of projection views on EchoPAC when the entire recording is stored to file Safety Conformance The Vivid T8 is e CE Marked to Council Directive 93 42 EEC on Medical Devices Conforms to the following standards for safety e IEC 60601 1 Medical electrical equipment Part 1 General requirements for safety e IEC 60601 1 2 Medial electrical equipment Part 1 2 General requirements for safety Vivid T8 product datasheet April 2014 DOC1509022 Page 8 of 10 Collateral Standard Electromagnetic compatibility requirements and tests EMC Emissions Group 1 Class A device requirements as per CISPR 11 IEC 60601 2 37 Medical electrical equipment Part 2 37 Particular requirements for the safety of ultrasonic medical diagnostic and monitoring equipment ISO 10993 1 Biological evaluation of medical devices
23. t April 2014 DOC1509022 Page 3 of 10 Image and Data Management Exceptional workflow with instant access data management DICOM SR standard structured reporting mechanism Next generation of DICOM Image Format Raw image DICOM incorpo rates raw image data information with its data management flexibility into the image communication standard DICOM Available on the scanner and EchoPAC 2D CFM or TVI data at maximum frame rate may be reviewed by scrolling or by running cine loops can contain more than 1 000 images for imaging modes Image clipboard for stamp size storage and review of stored images and loops Built in patient archive with images loops patient information measurements and reports Structured findings report tools help support efficient text entries with direct editing of findings text usability enhancements new configuration options and conclusion section User can enter normal values which are then compared to actual measurements Configurable HTML based report function Report templates can be customized on board ASE based default text modules English user customizable Internal archive data can be exported to removable image storage through DICOM media Internal hard disk for storing programs application defaults ultrasound images and patient archive All data storage is based on ultrasound raw data allowing to change gain baseline color maps sweep speeds etc for
24. to a single image in real time to help improve border definition contrast resolution and reducing angular dependence of border or edge as compared to previous generation GE products LOGIQView provides the ability to construct and view a static 2D image with wider field of view of a given transducer This allows viewing and measurements of anatomy that is larger than what would fit in a single image replay or image clipboard recall e Digital replay for retrospective review or automatic looping of images allowing for adjustment of parameters such as gain reject anatomical M mode persistence and replay speed e Data dependent processing performs temporal processing which helps reduce random noise but leaves motion of significant tissue structures largely unaffected can be adjusted even in digital replay 256 shades of gray Colorized 2D mode user selectable in real time digital replay M mode e Trackball steers M mode line available with all imaging probes max steering angle is probe dependent e Simultaneous real time 2D and M mode e M mode image data acquired is combined to give high quality recording regardless of display scroll speed Digital replay for retrospective review of spectral data e Several top bottom formats side by side format and time motion only format can be adjusted in live or digital replay L R and up down invert in live digital e Selectable horizontal scro
Download Pdf Manuals
Related Search
Related Contents
XD-SERIES 社会・環境報告 2005 Manuel d`utilisation "VMF" series Hitachi CP-RX80 User's Manual Helping Hand Company Cushion Shop User Manual YDT-730 の取扱説明書はこちら Tristar MX-4162 mixer MANUEL D`UTILISATION ET D`ENTRETIEN LISTE DES PIÈCES Les Archives départementales du Calvados - 5,3 Mo - pdf Copyright © All rights reserved.