        QTA Tracer User Manual ver 1.0
         Contents
1.               ccccccseeeceeeeseeeeeeeees 12  3 4 3 Tracer St  tUSieossssssreseoseoseorerrerrerrerrerrerrrrrrrrrr nns rn rens ennen reor rna 13  3 4 4 Tracer battery level  insssssssessessrsreorresreorrerrrnrrrrrrrrrnr narr annan 13  3 4 5 Blood bag information tab  lssnnsssssssssessrsrresrrerrrnrrnr rer renr nanna 13  3 5 Manually release blood from QUaranNtiNG    ss ssssesseoresrerrerrrerrerrrr rann 14  36  CHange language sorcer rne E a 15  Tridentify AB    Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden  www qtatracersystem com    Document title Updated  QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06    1 Introduction   Blood should be stored at two  2  to five  5  degrees Celsius to maintain as long as  possible  Under optimal conditions the shelf life is 42 days  In practice  healthcare has  shorter storage times  according to surveys  between 20 and 25 days  One reason for  this is that blood bags  when they leave the controlled and safe environment within  blood centers and comes out in health care  they are stored in a manner that is not  always safe  This can include the radiator is broken  shipments will take longer than  expected or blood bags that are picked out of the fridge but not used    These uncertainties mean that medical personnel  to be on the safe side  are forced to  throw blood because they do not always know what temperatures it is exposed to     QTA Tracer System   eliminates the uncertainty as it con
2.   se QTA Access Point Configurator manual     To release blood from quarantine  follow these steps   1  Select the    Status    tab  Status is shown as below in Figure 6   2  Connect to QTA Tracer as described above in 3 1   3  Ifthe blood not already is released  use one of the following options to release    blood     o Use the push button    Release blood from quarantine    or  o Scan the bar code on the screen to release blood    See below in    Figure 6     4  The QTA Tracer is automatically disconnected when the blood is released  See  below in Figure 7           EJ QTA Access Point   QTA Tracer System  File Language Help    QTA ci     QTA Tracer                   Id  3  2db784e865 J  Newlog   Status    Tracer status Blood bag information  Blood valid  as 100  Details on  00201200002402 Collection date  15 mar 2012 07 52  identification no   Blood released from x  quaratine  Blood group  6200 Expire date  26 apr 2012 23 59  Tracer status  Running ae eee pee ae 3846000  Tracer battery level    100        i  a  Release blood from a     quarantine E                      Figure 6 Release blood    Tridentify AB    Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden    www qtatracersystem com    Document title Updated    QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06          QTA Access Point   QTA Tracer System  gt   ba  File Language Help    QTA CS  POINT  J Blood released from quarantine for QTA Tracer 3c2db784e865    QTA Trace
3.  that  no unauthorized person shall have access to the Software  The User  including any related Account Holder  shall not  divulge  sublicense  assign  or transfer to any third party the user name and password established during registration or  provided to the User  The User  including any related Account Holder  understands that provision of the user name and  password may be required prior to each use of the Software  The Software and Content are the valuable property of  Tridentify  the unauthorized use or disclosure of which would irreparably harm Tridentify  Upon learning of any  unauthorized possession or use of or access to the Software  you or an agent of a related Account Holder  will notify  Tridentify  will promptly furnish details of such occurrence  will assist in preventing any recurrence thereof  and will  cooperate fully in any litigation or other proceedings undertaken to protect Tridentify   s rights     13  General  Any cause of action you may have with respect to your use of the Software  the Content or the Servers must  be commenced within one  1  year after the claim or cause of action arises  If for any reason any provision of this EULA  Agreement is determined to be invalid or unenforceable under any statute or rule of law by a court of competent  jurisdiction  such provision shall be interpreted in order to give effect to such provision to the maximum extent permitted  by law  and the remaining provisions shall continue in full force and effect  Thi
4. A  tracer and the address is also printed in plaintext below the bar code on  the QTA Tracer   Use this unique id when reporting a claim     3c2db784e765    Scan this bar code using QTA Access Point to connect to a QTA Tracer     K Waste Electrical and Electronic Equipment  WEEE  Statement  Return  product to distributor   BE Read the manual before use    gt   QTA Tracer includes Bluetooth technology     QTA Tracer product number   CE Certified by notified body 0402        Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden  www qtatracersystem com    Document title Updated  QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06    1 7 2 QTA Access Point  The QTA Access Point is a PC installed with the QTA Tracer System   and a Bluetooth USB  Dongle inserted in the USB port     To start or readout stored information from the QTA Tracer the QTA Access Point is  needed  QTA Access Point is used to    e Start anew QTA Tracer logging   e Readout status and temperatures from QTA Tracer   e Release blood from quarantine   e Readout stored information on the QTA Tracer    To configure the QTA Tracer System   a QTA Access Point Configurator is needed  The  QTA Access Point Configurator stores configuration parameters in the database that is  used by the QTA Access Point    QTA Access Point Configurator is managed by the QTA Tracer System distributor or the  local system manager     1 8 How the QTA Tracer defines the blood status  T
5. QTA cis     Version 1 0    QTA Access Point    Version 1 0 0 6       User manual    2014 05 20    LE     Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 90 Gothenburg  Sweden  www qtatracersystem com    Document title Updated  QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06    Table of Contents    1 Introduction 3  TA BACKOOUNO ater testi ice etcetera nate et gees sis 3  Pie IUD OSC wemsrsarn E E boul mtunnu incon sr 3  Wicd  AUO S ee a R oupseee dang easeeatasesseasseseneatee  3  1 4 System requirements              ccccseccceeecceeeceeceeeeceeeceeceseeeneeesueeeeeens 3  1 5 End User License Agreement  EULA                ccccseceseeeeeeeeeeeeeeeees 4  1 6 System OVEFVICW          cccceccccceececeeeeeseeeeseeeeceucessueeesesesseessaeessaeeesees 7  Wek SYSTEM MONG HOM  sercis eire AEE E E AE i 7   ie OTA WAC a stans rn  dslsssnnisi  istiinissennor sn  n 7  1 72  QTA ACCESS POM eee ene eee eee ee 8  1 8 How the QTA Tracer defines the blood status                    s   s r 20 8    Installation YD  Usage 10    3 1 Connect to a QTA Tracer iccccscstesnesened ccsusstenoncucantateadennwednenisecenns 10  3 2 Start a new LOGGING oosnoseessressresrressresrrerrrenrrrnrrrr rna rr rrr rr rr rn rr nn rr norr an 11  3 3 Read status using QTA Tracer sssmrmsrrsssrresrresssreorrreorrrrorrrrnrr reor nanna 11  3 4 Read QTA Tracer status using QTA Access Point                        11  SvT B  G valid acct seers N 12  3 4 2 Blood released from quarantine
6. T BETWEEN Tridentify AB     Tridentify   AND YOU   You  OR  User    ALONG  WITH ANY RELATED INSTITUTIONAL ACCOUNT HOLDERS THAT PROVIDED YOU WITH ACCESS TO THE SOFTWARE  THE   Account Holder    TRIDENTIFY IS WILLING TO LICENSE THE SOFTWARE PROVIDED TO YOU  WHETHER BY DOWNLOAD   VIA THE INTERNET  AS PART OF A DEVICE OR PIECE OF EQUIPMENT  OR ON SOFTWARE MEDIA  INCLUDING ALL  DATABASES  DATA  AND DOCUMENTATION CONTAINED THEREIN OR PROVIDED THEREWITH  THE  SOFTWARE   TO  YOU ONLY UPON THE CONDITION THAT YOU ACCEPT ALL OF THE TERMS AND CONDITIONS CONTAINED IN THIS EULA  AGREEMENT  BY DOWNLOADING ACCESSING OR USING SOFTWARE  YOU AFFIRMATIVELY ACCEPT ALL OF THE TERMS  AND CONDITIONS OF THIS EULA AGREEMENT AND AGREE TO BE BOUND BY ITS PROVISIONS AS OUTLINED HEREIN  BOTH FOR YOURSELF AND ON BEHALF OF ANY RELATED ACCOUNT HOLDER  WHICH INCLUDE YOUR REPRESENTATION  THAT YOU HAVE AUTHORITY TO BIND THE ACCOUNT HOLDER  IF YOU DO NOT ACCEPT THE TERMS OF THIS EULA  AGREEMENT  YOU ARE NOT PERMITTED TO USE THE SOFTWARE AND YOU MUST NOT DOWNLOAD  ACCESS OR USE  THE SOFTWARE     1  License  Tridentify grants  and the User and any related Account Holder hereby accepts  a nonexclusive   nontransferable  revocable license to use the Software on the terms and conditions set forth in this EULA Agreement  If  the Software is provided on software media  the User and any related Account Holder may make one copy of the  Software in machine readable form for backup purposes only  The backup copy must inclu
7. aws or regulations  including U S  Department of Commerce Export Administration  regulations and other applicable laws  or  H  use the Software in a manner where failure or malfunction could lead to  possible loss of life or catastrophic property damage     2  Termination  The User may terminate this EULA Agreement at any time by notifying Tridentify in writing  Tridentify may  at its sole discretion terminate this EULA Agreement at any time  with or without prior notification  in the event the User  fails to comply with the terms and conditions of this EULA Agreement  by deactivating the User s username and password  or suspending operation of the system  Tridentify reserves the right to terminate this EULA Agreement  or to modify or  terminate services and or product offerings in connection with the Software  at any time without notice to the User   Termination of this EULA Agreement between a User and Tridentify shall only act to discontinue User s personal access to  the Software and such termination shall not act to terminate this EULA Agreement or any other contracts related to the  Software between any related Account Holder and Tridentify     3  Copyright and Restrictions  The Software  including all text and other content therein   Content   is the property of  Tridentify or its licensors  and is protected by copyright and other intellectual property laws  Except for the rights  expressly granted above  this EULA Agreement transfers to User  including any related Acc
8. de all copyright information  contained on the original  If the Software is provided via the Internet  then the license herein includes a license to access  servers controlled by Tridentify   Servers   only for the purpose of accessing the Software    You may not do any of the following yourself  or through any third party or the Account Holder  and you may not permit  any third party with whom you have a business or personal relationship to do any of the following   A  copy the Software   except as expressly set forth above   B  modify or create derivative works based upon the Software   C  decompile   disassemble  or reverse engineer the Software in whole or in part   D  defeat  disable  or circumvent any protection  mechanism related to the Software   E  sell  license  sublicense  lease  rent  distribute  disclose  permit access to  or  transfer to any third party  whether for profit or without charge  any portion of the Software  or  in particular  without  limiting the generality of the foregoing  distribute the Software on any media  make the Software accessible to the public  or third parties  whether over networks  electronic bulletin boards  websites  or otherwise  or allow any third party to use  the Software   F  publish or otherwise communicate any review of  or information about  the performance of the  Software to any third party without the prior written consent of Tridentify   G  export  re export  download  or otherwise  use the Software in violation of any l
9. ed to any related  Account Holder  The rights and obligations contained herein may not be assigned to any other party     Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden    www qtatracersystem com    Document title Updated  QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06    1 6 System overview   The QTA Tracer system is built up by a PC installed with the QTA Tracer System    a  Bluetooth USB dongle  a Barcode reader and a QTA Tracer    Figure 1 displays the QTA Tracer system        Barcode Reader PC with Bluetooth 4 0 USB Dongle QTA Tracer    Figure 1  The QTA Tracer System      1 7 System function    1 7 1 QTA Tracer   The QTA Tracer is placed on a blood bag to measure temperatures and calculate if the  blood is valid according to specific configuration parameters that is defined by each  blood center     There is no specific rule when to attach the QTA Tracer to the blood bag  because it  depends on the unique process that is used on each blood center     The QTA Tracer has a motion detector that turns the tracer on and starts to show the  status of the blood and makes it enable for communication thru LED   The QTA Tracer is labeled with the following labels     wv  Blood is ok   green light   functional     a J  Blood is not ok   red light  nonfunctional         This is a bar code including the Bluetooth address for the QTA Tracer   see The Bluetooth address is the unique identifier  serial number  for the QT
10. er System       Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden    www qtatracersystem com    Document title Updated  QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06       3 Usage    3 1 Connect to a QTA Tracer  To connect to a QTA Tracer from a QTA Access point  follow these steps   1  Start the QTA Access Point program   2  Turnonthe QTA Tracer by moving it  tilting it slowly  One of the LED ane  will then blink  green or red  2 m  3  Scan the bar code on the QTA Tracer using the bar code reader   The QTA Access Point notifies that the connection is established by displaying tiic uin  Tracer Id in the Current QTA Tracer field as shown below in Figure 2   To connect a QTA Tracer it needs to reach a specific temperature before reading  For  more information on the current temperature level  contact your system administrator           r  El QTA Access Point   QTA Tracer System  File Language Help    ATAS    J Connectto QTA Tracer  3c2db784e865    QTA Trocer    Id  3c2db784e865 J  Disconnect    New log   Status    Donation identification no   Blood group   Product code     Collection date     Expire date        Clear all fields                            Figure 2 Connect to QTA Tracer    Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden    www qtatracersystem com    Document title Updated  QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06    3 2 Start a ne
11. er s  including any related Account Holder s  sole risk  Tridentify does not  directly or indirectly practice medicine or dispense medical services and assumes no liability for the Software  the Content  or the Servers  The User  including any related Account Holder  assumes full responsibility for the appropriate use of  medical information contained in the Software or the Content and agrees to hold Tridentify  and its third party providers   harmless from any and all claims or actions arising from User s  including any related Account Holder  use of the Software   the Content or the Servers  User and any related Account Holder agrees to defend  indemnify and hold harmless  Tridentify  its affiliates and third party providers from and against all claims  losses  damages  costs and expenses   including attorney fees  arising out of their use of Software  the Content and the Servers     7  Third Party software  hardware and content  Software may be provided with third party plug ins or other third party  software  or this Software may be provided as a plug in for  or otherwise in association with  third party software  Use of  any such third party software will be governed by the applicable license agreement  if any  with such third party  For  software  hardware or Content obtained from third party licensors  the User and any related Account Holder are solely  responsible for compliance with any copyright restrictions and is referred to the publication data appearing in  bibl
12. he blood status is shown with the following label symbols in both QTA Tracer and QTA  Access Point     e     Blood is ok  green light   functional     e AK Blood is not ok  red light   nonfunctional  e    no light  Blood is not ok  the QTA Tracer is not operating as it should    The blood status is calculated by the QTA Tracer and is marked as x  Blood is not ok  if  one of following conditions is true   e If the blood has been exposed for too low  or too high temperature  e If the blood has been exposed in the different temperature ranges for too long   The temperature ranges is configured in the database   e If both of the following start logging delays not has been reached   o Start time delay     Wait for a specific time  specified in the configuration  o Start at temperature     Wait for a specific temperature is reached   specified in the configuration  e If the blood not has been released from quarantine  e lf an error occur in the QTA Tracer     Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden  www qtatracersystem com    Document title Updated  QTA Tracer User Manual ver 1 0 2013 05 20    with QTA Access Point v1 0 06       2 Installation    The installation process of the QTA Tracer System   is described in the installation  instructions  The installation is performed by personnel from Abbott or Tridentify  The  installation can be done by a local system manager that has gone through a training  program how to set up the QTA Trac
13. he product descriptions or other Content  Tridentify does not assume  and expressly disclaims  any obligation to  obtain and include any information other than that provided in the Content  It should be understood that by making this  material available  Tridentify is not endorsing or advocating the use of any product described in the Content  nor is  Tridentify responsible for misuse of a product due to  or other consequence of  any typographical error or other  inaccuracy  Additional information on any product may be obtained from the manufacturer     Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden  www qtatracersystem com    Document title Updated    QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06       5  Use of Professional Judgment  The Content is no substitute for individual patient assessment based upon the  healthcare provider s examination of each patient and consideration of laboratory data and other factors unique to the  patient  The Software should be used as a tool to help the User and any related Account Holder reach or understand  diagnostic and treatment decisions  bearing in mind that individual and unique circumstances may lead the User  User s  healthcare provider  or Account Holder to reach decisions not presented in the Software     6  User Indemnity  User  including any related Account Holder  expressly acknowledges and agrees that use of the  Software  the Content and the Servers is at Us
14. iographic citations  as well as to the copyright notices appearing in the original publications  TRIDENTIFY IS NOT  RESPONSIBLE FOR ANY THIRD PARTY SOFTWARE  HARDWARE OR CONTENT AND WILL HAVE NO LIABILITY OF ANY  KIND FOR YOUR USE OF SUCH THIRD PARTY SOFTWARE  HARDWARE OR CONTENT AND MAKES NO WARRANTY OF ANY  KIND WITH RESPECT TO SUCH THIRD PARTY SOFTWARE  HARDWARE OR CONTENT     8  Exclusion of Warranties  While great care has been taken to ensure the accuracy of the Software and the Content   Tridentify assumes no responsibility therefore  ALL SOFTWARE  SERVICES AND CONTENT ARE PROVIDED  AS IS  AND     AS AVAILABLE     EXCEPT TO THE EXTENT PROHIBITED BY LAW  TRIDENTIFY EXPRESSLY DISCLAIMS ANY  REPRESENTATIONS OR WARRANTIES OF ANY KIND  EXPRESS OR IMPLIED  INCLUDING WITHOUT LIMITATION  WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE  NON INFRINGEMENT  THAT THE  SOFTWARE  THE CONTENT  OR THE PERFORMANCE OF THE SERVERS WILL MEET USER S  INCLUDING ANY RELATED  ACCOUNT HOLDER S  REQUIREMENTS  THAT THE OPERATION OF THE SOFTWARE OR THE SERVERS WILL BE  UNINTERRUPTED OR ERROR FREE  OR REGARDING THE USE OR THE RESULTS OF THE USE OF THE SOFTWARE   INCLUDING THE RELATED DOCUMENTATION   THE CONTENT  OR THE SERVERS IN TERMS OF THEIR CORRECTNESS   ACCURACY  RELIABILITY  OR OTHERWISE  ALL SUCH REPRESENTATIONS  WARRANTIES AND CONDITIONS ARE  EXCLUDED    No salesperson or other representative of any party involved in the distribution of the Software is authorized to make a
15. k  Medicinaregatan 8A  413 46 Gothenburg  Sweden  www qtatracersystem com    Document title Updated    QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06       2  Connect to the QTA Tracer as described above in 3 1     E  QTA Access Point   QTA Tracer System       File Language Help  OT ACCESS  POINT    QTA Tracer  Id  3c2db784e865    New log   Status             Tracer status Blood bag information    Blood valid  x poA S00201200002402 Collection date  15 mar 2012 07 52  identification no     Blood released from J  quaratine  Blood group  6200 Expire date  26 apr 2012 23 59    Tracer status  Wait start    Tracer battery level  97     Product code  E3846000                               Figure 4 Read QTA Tracer    3 4 1 Blood valid    In Figure 4 the blood is not valid  because the QTA Tracer is in status  Wait for start  How QTA Tracer defines the blood status is described in 1 8    The percentage shows how many percent is left until the blood is not ok    For a QTA Tracer logging that has been started  move the mouse over the percentage to  see the calculated time left  See example in Figure 5 Calculated time left for the blood is  configured in the QTA Tracer       EJ Calculated time left    Calculated time left for the temperature intervals configured in the connected QTA  Tracer     Temperature  lt  1  C 0 days  0 hours  0 minutes  Temperature  lt  10  C 41 days  11 hours  24 minutes  Temperature  lt  24  C 0 days  23 hours  42 minutes  Temperature  
16. lt  30  C 0 days  3 hours  57 minutes       Figure 5 Time to live    3 4 2 Blood released from quarantine   Showing if the blood is released from quarantine or not     Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden    www qtatracersystem com          Document title Updated  QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06    3 4 3 Tracer status   The Tracer status can have the following modes   e Running   QTA Tracer log temperatures and calculate if blood is valid  e Wait start     QTA Tracer wait for one of the following to be true  o Start time delay     Wait for a time  specified in the configuration  o Start at temperature     Wait for a temperature is reached  specified in the  configuration  e Error     An error has occurred on the QTA Tracer     3 4 4 Tracer battery level   Showing if the battery level is ok or not  The percentage shows how many percent it is  left before the battery is empty of power     3 4 5 Blood bag information tab   The blood bag information that is stored in the QTA Tracer for the current logging     Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden  www qtatracersystem com    Document title    QTA Tracer User Manual ver 1 0    Updated  2013 05 20       with QTA Access Point v1 0 06    3 5 Manually release blood from quarantine  To release blood from quarantine manually  the release blood from quarantine  configuration must be set to manual mode
17. ny  warranties with respect to the Software  the Content  or the Servers beyond those contained in this EULA Agreement   Oral statements do not constitute warranties  shall not be relied upon by the User  and are not a part of this EULA  Agreement     9  Limitation of Liability  EXCEPT TO THE EXTENT PROHIBITED BY LAW  IN NO EVENT  INCLUDING NEGLIGENCE  WILL  TRIDENTIFY  OR ANY OTHER PARTY INVOLVED IN THE CREATION  PRODUCTION  PROMOTION  OR MARKETING OF THE  SOFTWARE  THE CONTENT  OR THE SERVERS  BE LIABLE FOR ANY INCIDENTAL  SPECIAL  INDIRECT  RELIANCE  PUNITIVE  OR CONSEQUENTIAL DAMAGES  INCLUDING LOST DATA  BUSINESS INTERRUPTION  LOSS OF USE  LOST REVENUE  OR  LOST PROFITS  ARISING OUT OF OR RELATING TO THIS LICENSE OR THE SOFTWARE  THE CONTENT  OR THE SERVERS   EVEN IF TRIDENTIFY OR SUCH OTHER PARTY HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES  In no event  will the total liability of Tridentify or such other party for all damages exceed the license fees paid by the User or any  related Account Holder for the Software for the current term of this EULA Agreement     10  Exclusive Remedy  Except to the extent prohibited by law  If Tridentify does not comply with its undertakings under  this EULA Agreement  it shall either correct the non compliance or  at its option  terminate this EULA Agreement by prior  notice  This clause expresses your sole and exclusive remedy in relation to non compliance by Tridentify     11  Beta Release Versions  In the event that the Softwa
18. ount Holder  no right  title  or  interest in the Software  or the Content or any copyright  patent  trademark  trade secret  or other intellectual property  or proprietary right therein  Tridentify retains sole and exclusive title to all portions of the Software and the Content  and  any copies thereof  and User  including any related Account Holder  hereby assigns to Tridentify all right  title  and  interest in and to any modifications User or Account Holder makes to the Software  whether or not such modifications  are permitted  None of the Content may be reproduced  transcribed  stored in a retrieval system  translated into any  spoken language or computer language  retransmitted in any form or by any means  electronic  mechanical  photocopied   recorded  or otherwise   resold  or redistributed without the prior written consent of Tridentify  except that the User may  reproduce limited excerpts of Content obtained from Tridentify sources or databases for personal use only  provided that  each such copy contains a copyright notice as follows     Copyright   by Tridentify AB  All rights reserved      4  Content Provided by Tridentify  While great care has been taken in organizing and presenting the Content  Tridentify  does not warrant or guarantee its correctness  accuracy  or timeliness  including with respect to any product descriptions   prices  or information concerning medical devices  Tridentify does not perform any independent analysis or investigation  of any of t
19. r    Id     Disconnect          Tracer status Blood bag information   Blood valid  Rees Collection date   identification no    Blood released fro   quaratine  Blood group  Expire date    Tracer status  eee codi    Tracer battery level                 Figure 7 Blood released    3 6 Change language    Select    Language    in the menu and pick one of the languages in the drop down list  see  figure 7     Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden  www qtatracersystem com    
20. re is identified as a beta release version   Beta Version    the terms  of this paragraph will apply in addition to or in lieu of the other terms of this EULA Agreement  Your license  including the  license of any related Account Holder  to use the Beta Version expires at the end of the period indicated by the Software   or if no such period is indicated  120 days after installation  The Beta Version may cease to function  The Beta Version  may contain more  fewer  or different features than are contained in the commercial release corresponding to the Beta  Version that Tridentify intends to or does distribute  Tridentify reserves the right at any time to withhold the release of a  commercial version corresponding to the Beta Version  or if Tridentify does release such a commercial version  to alter  features  specifications  capabilities  functions  licensing terms  release dates  general availability  or other characteristics  of such commercial version  User  including any related Account Holder  acknowledges and understands that the Beta  Version is not suitable for production use and may contain errors affecting its proper operation     Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden    www qtatracersystem com    Document title Updated    QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06       12  Protection and Security  The User  including any related Account Holder  shall take all reasonable steps to ensure
21. s EULA Agreement and all related business  transactions shall be governed by the substantive laws of Sweden  The Parties agree that the United Nations Convention  on Contracts for the International Sale of Goods   1980   as amended  is specifically excluded from application to this  Agreement  Any dispute  controversy or claim arising out of or in connection with this EULA Agreement  or the breach   termination or invalidity thereof  shall be finally settled by arbitration in accordance with the Rules for Expedited  Arbitrations of the Arbitration Institute of the Stockholm Chamber of Commerce  The arbitration proceedings shall be  conducted in the English language and take place in Stockholm  Sweden  This EULA Agreement constitutes the entire  agreement between the parties with respect to the subject matter hereof and supersedes all prior agreements  oral or  written  and all other communications relating to the subject matter hereof  No amendment or modification of any  provision of this EULA Agreement will be effective unless set forth in a document that purports to amend this EULA  Agreement and both parties accept that hereto  Tridentify may change these terms and conditions in this EULA  Agreement from time to time by posting revised terms and conditions on  http   www qtatracersystem com web guest disclaimer  and all such changes will be effective when You next use the  site or after 30 days  whichever is sooner  This EULA Agreement is personal to User and it is assign
22. tinuously measures the  temperature of the blood and stores the information  The QTA Tracer is attached to the  blood bag to verify the quality of the blood over the blood bags whole lifetime  When  personnel take up the blood bag  the QTA Tracer is activated and it responds with a  green or red light depending on whether the blood is healthy and can be used or if it  must be discarded     1 1 Background  This user manual is part of the QTA Tracer System   version 1 0    1 2 Purpose  The purpose of this document is to give knowledge to end users of the QTA Tracer and  the QTA Access Point     1 3 Audience  The audience of this document is end users of the QTA Tracer System       1 4 System requirements   The following accessories is needed to use the QTA Tracer System     PC with Windows 7 Note book  Lap Top or stationary PC  2Mb  RAM  Physical storage  gt  100Mb  Delivered by Abbott or by the local IT    department on the hospital     Bluetooth 4 0 Single Mode USB Dongle Delivered by Abbott  Bar code reader reading 2D bar codes Delivered by Abbott  QTA Tracer Delivered by Abbott       Tridentify AB  Sahlgrenska Science Park  Medicinaregatan 8A  413 46 Gothenburg  Sweden  www qtatracersystem com    Document title Updated    QTA Tracer User Manual ver 1 0 2013 05 20  with QTA Access Point v1 0 06       1 5 End User License Agreement  EULA     PLEASE READ THE FOLLOWING TRIDENTIFY END USER LICENSE AGREEMENT   EULA Agreement   CAREFULLY BEFORE  CONTINUING  THIS IS A LEGAL CONTRAC
23. w logging  To start a new QTA Tracer logging  follow these steps   1  Select the    New log    tab   2  Connect to the QTA Tracer as described above in 3 1   3  Scan the following bar codes on the blood bag   Donation Identification no  Blood group  Collection date  Expire date  Product code  The QTA Tracer logging is automatically started and disconnected when all bar codes  is scanned as described above and the QTA Access point notifies that logging is  started with a sound signal and as shown below in Figure 3     O O O O 0       r  QTA Access Point   QTA Tracer System  File Language Help    OT ACCESS  POINT  J Logging is started for QTA Tracer  3c2db784e865    QTA Trocer       Id  Disconnect    New log Status      Donation identification no   Blood group    Product code    Collection date     Expire date        Clear all fields                   Figure 3 New QTA Tracer logging    3 3 Read status using QTA Tracer  To see if the blood is valid on the QTA Tracer  follow these steps   e     Turn on the QTA Tracer by moving it   e The status of the blood is indicated by  o   Blood is ok  green light   functional    O a  Blood is not ok  red light   nonfunctional  o     no light  Blood is not ok  the QTA Tracer is not operating as it  should    3 4 Read QTA Tracer status using QTA Access Point  To read a QTA Tracer status using a QTA Access Point  follow these steps   1  Select the    Status    tab  Status is shown as below in Figure 4     Tridentify AB  Sahlgrenska Science Par
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Product Sheet  Manual del usuario - Sistema de clasificación docente comprimido  ATC1 user manual.indd  FEMA ELECTRÓNICA  775D Dual Directional Coupler Operating and Service Manual  User Manual    Emulex Driver for Linux Version 8.2.0.48.2p User Manual  Kurzweil PC3LE8 MIDI keyboard    Copyright © All rights reserved. 