Home

OPS-Q Series Power Supplies

image

Contents

1. TE cooled LIK LMP light intensity controller kit e RoHS and CE compliant 20 0008660 ea6e008090 0G308660 a egegnaeaedea LAR AZZAR a 280000090 Ms D E Ure INSTRUMENTS A Newport Company OPS Q SERIES POWER SUPPLIES Lamp Power eee PP 3 ie i ili ei During operation the user has the ability to observe in real time the voltage current and power supplied to the lamp as well as how many hours the lamp has been operated and the output intensity of the lamp Observing the output intensity of the lamp requires the use of the LIK LMP Light Intensity Controller Kit sold separately LAMP OPERATION MODES The OPS model power supplies allow the lamp to be operated in power current and intensity control modes As a default setting the OPS Q model power supplies are set to current mode There is very little difference in the short term output stability when operating a QTH lamp in constant current or constant power mode However the differences appear as the lamp ages Even with a stable power supply deposits on the inside of the lamp envelope are visible as the lamp filament degrades changing the electrical characteristics of the lamp Constant Power Mode In power mode the lamp is operated at a constant power setting As the voltage cannot be changed the current is raised or lowered to maintain the powe
2. OPS Q Series Power Supplies The OPS Q model power supplies by Oriel are designed to meet the precise requirements for proper operation of Quartz Tungsten Halogen QTH lamps These power supplies are capable of operating in constant power constant current and intensity modes to produce the high stability light output typically required for radiometric measurement when used with the appropriate Oriel lamp lamp housing and if necessary socket adapter USER INTERFACE A power switch and all manually controllable features of the OPS model power supplies are accessible from the front panel Four horizontal push buttons each activate a horizontal menu that allows for configuring of lamp operating mode shutter display mode and setup with the help of a corresponding vertical menu that is activated as well These functions are conveniently displayed and easily navigated by the LCD display on the front panel of the power supply aD Newport OAIEL INST TRUM ENTE B e High stability power supply for 45 1000 W Quartz Tungsten Halogen lamps e Capable of operating lamps in current power and intensity control modes e Large LCD display for easy setup and monitoring RS 232 and USB interfaces located on rear panel for remote lamp operation and monitoring e USB interface located on front panel for firmware updates e Light intensity shutter control and timer features integrated e Integrated temperature controller for
3. V mm Color Temperature 45 6 8 V 4 75 H x 1 5 Dia ome 45 6 8V 4 75 H x 1 5 Dia ikea 50 12 V 1 5 x 5 2 3000 1000 120 V 6 0 x 16 0 3200 1000 120 V 6 0 x 16 0 3200 Refer to calibration certificate supplied with lamp Q Series Housing Socket Assemblies Model 60043 60046 Rod Mount Model 63966 63965 Q Series Housing Model 60000 Description Socket Adapter 50 to 250W OTH Lamps For Q Series and Research Series Lamp Housings Socket Adapter Q Series Vertical 50 100 W Quartz Tungsten Halogen Lamps Description Lamp Mount 45 to 200 W QTH Calibrated Source Lamps Lamp Mount 1000 W Quartz Tungsten Halogen Calibrated Source Lamps Description Q Series Lamp Housing Holds Adjustable Reflectors And Up to 4 Condensers Research Lamp Housing Socket Assemblies Model 60043 6392NS 6397 Description Socket Adapter 50 to 250W QTH Lamps For Q Series and Research Series Lamp Housings Socket Adapter Socket Adapter 1kW OTH CE Research Lamp Housings Model 66882 66883 66884 67009 67011 66885 66886 Description Research QTH Lamp Housing 10 250W F 1 5 Single Element FS Collimated Research QTH Lamp Housing 10 250W F 0 7 4 Element Aspherab Collimated Research QTH Lamp Housing 10 250W F 1 2 Element FS Collimated Research QTH Lamp Housing 10 250 W F 2 2 FS Asphere Collimated Research QTH Lamp Housing 10 250 W F 1 FS Asphere Collimated Research QTH Lamp Housing 600 1000W F 1 2 Element FS Collim
4. ated Research QTH Lamp Housing 600 1000W F 7 4 Element Aspherab Collimated OPS Q Series Ordering Table Model OPS 0250 OPS 01000 Description 45 250 W QTH Lamp Power Supply Power Current and Intensity Control Modes RS 232 USB control CE and RoHS compliant 600 1000 W OTH Lamp Power Supply Power Current and Intensity Control Modes RS 232 USB control CE and RoHS compliant Permissible Burning Position 0 or 90 0 or 90 0 or 90 0 or 90 0 or 90 0 or 90 0 or 90 0 or 90 0 or 90 0 or 90 0 or 90 0 or 90 Average Life h KKEK KKEK 50 3000 50 KKEK KKREK 50 300 KKREK DS 121405 12 14
5. ating in current or power mode with the help of the LIK LMP light intensity controller kit When a flux set point is established the user can activate intensity control and adjust the power output of the lamp by a flux multiplier factor ranging from 0 01 999 99 Intensity control mode requires the use of the LIK LMP light intensity controller kit The LIK LMP light intensity kit includes a TE cooled detector and all the necessary adapters and cables for mechanical and electrical compatibility with the lamp housing both 60000 Q Series and 10 1000 W Oriel Research Quartz Tungsten Halogen Lamp Housings adapters included and OPS model power supply When operating in intensity mode the user has the ability to adjust the idle current and maximum current to be supplied to the lamp OPS Q SERIES POWER SUPPLIES Lamp Intensity 100 uA Lamp Mode Sk Intensity Man After a flux set point is established the LCD screen of the OPS Power Supply allows the user to monitor in real time the output intensity of the lamp and increase or decrease this output intensity by a flux multiplier factor with the help of the LIK LMP sold seperately When To Use A Light Intensity Controller Although Oriel s power supplies are highly regulated there are factors beyond the control of the power supply that may affect light output Some of these are lamp aging ambient temperature fluctuations and electrode erosion For applications where high sta
6. bility light output is especially critical a LIK LMP Light Intensity Controller Kit is suggested in order to compensate for such factors It works in conjunction with the OPS Q Series power supplies to maintain a stable long term output 1 010 1 008 1 006 1 004 RELATIVE INTENSITY 1 002 1 000 TIME Hours Intensity of a QTH lamp with and without LIK LMP feedack LIK LMP Light Intensity Controller Kit Contents Part Number Description 71582 TE Cooled detector head for LIK LMP light intensity controller kit 70062 Cable Oriel Thermoelectric Cooler to TE Cooled Detectors 6 Foot 1 8 Meter Length 70018 Cable BNC Low Noise 6 Foot 1 8 Meter Length 68952 Adapter Kit Research Lamp Housing to Light Intensity Controller Timer 68954 Adapter Kit Q Series Lamp Housing to Light Intensity Controller Timer TRIGGER SHUTTER DETECTOR ol INPUT INPUT j C ROHS mapas ay ies aS CE ROHS gsr A a D o Iga lt iii Eps geci M D gt TE COOLER ete OUTPUT 1 z z D A a The housing of the LIK LMP s TE cooled detector includes BNC and a four pin connectors for easy light intensity feedback and TE cooler control when used with an OPS Model Power Supply The Research Lamp Housing shown in the picture is sold separately Output connectors are also located on the back panel of the OPS Series Power Supplies to relay the LIK LMP detector s feedback into light intensity data and control an
7. d monitor the detector s temperature The detector s feedback alerts the Power Supply to make necessary changes in power current to keep light intensity constant as the lamp ages EXTERNAL CONTROL A USB and an RS232 connector are located on the back panel of the OPS Q Series Power Supply Either connector can be used to allow the user to operate the power supply from a Windows based PC The User s Manual included with the power supply lists the necessary command set A USB connector is located on the front panel to install firmware updates to the power supply Any firmware updates if critical to the use and operation of the power supply will be available on the Newport website OPS Q SERIES POWER SUPPLIES SHUTTER CONTROLLER The shutter control feature of the OPS model power supply is useable in power current and intensity control modes Any shutter which responds by opening or closing when receiving a TTL signal can be controlled by the OPS Power Supplies This includes Oriel s model 71455 low cost TTL shutter and the shutters designed into the Oriel solar simulators A BNC connector is located on the rear panel of the power supply to output these TTL signals to the electronic shutter The shutter can be manually opened or closed by pressing the SHUTTER button on the front panel of the power supply RS232 or USB control of the shutter is possible as well Timed Exposure Timed exposure control mode is accessible in power cu
8. e aware of when the lamp s end of lifetime should be Lamp Hours Lamp Power 0029 18 26 With 1 s resolution the OPS Model Power Supply is capable of displaying how many hours the current lamp in operation has been operated for The important parameters for as many as four Setups can be saved and recalled for fast and convenient test setup in the future OPS Q SERIES POWER SUPPLIES QTH LAMP COMPATIBILITY Newport Corporation offers all the components required to assemble a complete illumination system The minimum components include a lamp lamp housing power supply and possibly a socket adapter The table below explains which components are compatible with each other to create an illumination system Compatible Oriel Lamp Housings or Rod Mounts Q Housing Research Lamp Housings Power Supply Lamp or IR Emitter Lamp or IR Emitter Description Socket Adapter Socket Adapter Rod Mount OPS 0250 63358 OTH 45 W N A N A 63966 CALIBRATED 63360 OTH 45 W N A N A 63966 UNCALIBRATED 6332 OTH 50 W 60000 Housing with 66881 66882 66883 66884 67009 N A SHORT FILAMENT 60090 Interface Kit 67011 60043 60043 6337 OTH 50 W 60000 Housing with 66881 66882 66883 66884 67009 N A LONG FILAMENT 60090 Interface Kit 67011 60043 60043 6333 QTH 100 W 60000 Housing with 66881 66882 66883 66884 67009 N A 60090 Interface Kit 67011 60043 60043 6363 IR EMITTER 140 W 60000 Housing with 66881 66882 66883 66884 67009 N A 60090 In
9. g door is open or a temperature problem has occurred Interlock Open Newport s Oriel Power Supplies have a safety interlock feature which must be satisfied before the power supply will power the lamp and if broken during operation will disable the power supply Overheating of the housing or accidental opening of the door will automatically shut down the power supply OPS 0250 OPS 01000 Approved Lamp Wattage 45 250 W 600 100 W Power Factor 20 99 Input Voltage 90 264 VAC 95 264 VAC Input Current Max 3A 13A Input Frequency 47 63 Hz Output Current Range 1 10 5 A 2 10 A Output Voltage Range 0 31 VDC 0 130 VDC Line Regulation 0 01 Output Voltage Ripple lt 0 05 rms Light Ripple Meter Accuracy of full scale lt 0 05 Digital Meter Resolution Voltage 0 01 VDC Digital Meter Resolution Power 1 W Digital Meter Resolution Current 0 01 A Safety Interlock Voltage 12 VDC GND Operating Mode Operating Temperature Max Relative Humidity Constant Current Power or Intensity 10 45 C 80 non condensing OPS Q SERIES POWER SUPPLIES QTH Lamp Specification Guide Model 63358 63360 6332 50 12V 1 6 x 3 3 3300 6337 6333 100 12V 2 3 X 4 2 3300 63355 200 30 V 7 0 H x 3 6 Dia oer 63368 200 30 V 7 0 H x 3 6 Dia D 6334NS 250 24 V 7 0 x 3 5 3400 63350 6315 1000 120 V 6 0 x 16 0 3200 63350 63362 1000 120 V 6 0 x 16 0 3200 Effective Filament Size Wattage W Lamp Voltage
10. r at the same level As the lamp ages the radiant output decreases As an IR emitter ages its resistance may double However the lamp life is prolonged Lamp Power 100 W The light bulb icon on the OPS Power Supply s LCD screen illuminates indicating the lamp is on Real time power supplied to the lamp is also visible to the user during operation Prior to igniting the lamp a user can set the maximum operating power of the lamp and the operating power he or she would like to operate the lamp at This prevents accidental damage to the lamp caused by supplying too much power Lamp Voltage The voltage current and power supplied can be displayed on the LCD screen of the OPS Power Supply while the lamp is being operated in al any mode Constant Current Mode In current mode the lamp is operated at a constant current setting As the voltage cannot be changed the power is raised or lowered to maintain the current at the same level As the lamp ages the power is increased This results in greater optical output which to some extent may help compensate for a darkening lamp envelope However the lamp life is reduced due to the increase in power Lamp Current i W 0 A The current supplied to the lamp is visible in real time during operation on the OPS Power Supply s front panel LCD screen Intensity Mode Lamp intensity mode allows the user to set a flux set point while the lamp is oper
11. rrent and intensity operation modes The exposure or open time of the shutter and number of repeat cycles is set by the user Exposure times can be paused and resumed at will or reset to 0 in the middle of an exposure with the easy to use push buttons on the front panel Dosed Exposure When light intensity control is enabled and simultaneously used with the shutter timer feature the OPS power supply can be set to deliver a specified dose of light to a sample The does is calculated as the total light flux multiplied by the time the shutter is open The dose feature is very similar to the internal shutter timer feature But instead of specifying a shutter open time the user specifies the desired dose The shutter is left open for however long it takes to reach this dose and then closes The user may set the close time and number of cycles for the sequence to repeat Just as with the internal shutter timer feature the user can pause continue or abort an exposure whenever necessary CONFIGURATION SETTINGS The OPS model power supplies are capable of storing up to four Setups These Setups consist of lamp operation mode with relevant parameter limits bower current flux etc and timing preferences for shutter and dosage control This allows a user to easily recall previous testing parameters to create a repeatable setup The power supply is also capable of logging the hours of operation the lamp has been in use to allow the user to b
12. terface Kit 67011 60041 60041 63355 OTH 200 W N A N A 63966 CALIBRATED 63368 OTH 200 W N A N A 63966 UNCALIBRATED 6334NS QTH 250 W N A 66881 66882 66883 66884 67009 N A 67011 60043 OPS 01000 6336 QTH 600 W N A 66885 66886 N A 6392NS 6315 OTH 1000 W N A 66885 66886 N A 6397 6317 QTH 1000 W N A 66885 66886 N A FEL 6392NS 63350 QTH 1000 W N A N A 63965 CALIBRATED 63362 QTH 1000 W N A N A 63965 UNCALIBRATED LAMP HOUSING CONNECTIONS The following Lamp Housing Interconnection Cable s is required for use with the appropriate OPS Q model power supply When using a rod mounted QTH lamp the necessary cable is built into the assembly Therefore a replacement cable for this item is not sold Model Lamp Housing Interconnection Cable OPS 0250 Oriel model 70050 6 ft length 70046 12 ft length 70047 20 ft length OPS 01000 The 70050 Lamp Housing Interconnection Cable offered by Newport Corporation SOFT START PROTECTS LAMPS These power supplies gradually apply power or current on lamp start up and gradually reduce power or current on lamp shut down This prevents catastrophic damage from in rush current on lamp start and minimizes stress to the lamp The reduction in thermal shock to calibrated lamps ensures longer validity of the calibration SAFETY INTERLOCK PREVENTS ACCIDENTAL EXPOSURE Lamp Power The Interlock Open indicator of the power supply indicates a cable is disconnected the lamp housin