Home

Pressure Reference Type D USER MANUAL

image

Contents

1. gas media Pressure connection G1 4 male Display multi purpose LCD 30 x 30 mm Function keys SELECT On Off function units ENTER confirm min max Casing 70 x 100 x 30 mm d xh x w Protection class IP65 Weight approx 130 g Power supply 3 V battery 1400 h service life continuous operation LOW BAT display AUTO Off Switchable pressure units bar mbar hPa PSI kPa MPa kg cm SIKA E oor 1901 Dr Siebert amp K hn GmbH amp Co KG Accuracy 0 10 FS 1 digit Measuring range Resolution Model A a 3 bar 0 001 bar Model B 1 30 40 bar 0 01 bar Model C 0 300 350 bar 0 1 bar Model D a 700 bar 0 2 bar Model E a 1000 bar 0 2 bar Option EEx ia IIC T5 T6 01ATEX6001X SIKA Dr Siebert amp K hn GmbH amp Co KG Struthweg 7 9 34260 Kaufungen Germany 4 4 Tel 49 5605 803 0 Fax 49 5605 803 54 email info SIKA net web www SIKA net
2. Pressure Reference Type D SIKA EEE oor 190 Dr Siebert amp K hn GmbH amp Co KG USER MANUAL Digital Manometer with Max Min Display Accuracy 0 1 FS typ The Reference Type D has two operating keys The left key SELECT serves to select the functions and the pressure units The right key ENTER activates the selected function or pressure unit The right key is also used to switch between the MAX and MIN value Turn on Pressing the SELECT key turns the instrument on The instrument subsequently displays the software version year week the full scale pressure range the actual pressure top display and the last measured MAX value bottom display The instrument has the following functions RESET Max Min value are set to the actual pressure OFF Turns off the instrument MANO Releases the following functions ZERO SEt Sets a new Zero reference ZERO rES Sets the Zero to factory setting CONT on Deactivates the automatic turn off function CONT off Activates the automatic turn off function the instrument turns off 15 minutes after the last key function followed by the unit selection bar mbar hPa kPa MPa PSI kg cm SIKA Dr Siebert amp K hn GmbH amp Co KG Struthweg 7 9 34260 Kaufungen Germany 1 4 Tel 49 5605 803 0 Fax 49 5605 803 54 email info SIKA net web www SIKA net Sika ee lt lt lt 1901 Dr Siebert amp Kuhn GmbH amp Co KG Example Se
3. starts flashing on the display SIKA Dr Siebert amp K hn GmbH amp Co KG Struthweg 7 9 34260 Kaufungen Germany 2 4 Tel 49 5605 803 0 Fax 49 5605 803 54 email info SIKA net web www SIKA net SIKA Ee oor 1901 Dr Siebert amp Kuhn GmbH amp Co KG Installation The Reference Type D has 7 16 UNF male thread and is delivered complete with an O ring seal swivel fitting which allows to be rotated through 360 Only minimal tightness is needed to seal up to 700 bar Process pressure connection is G 1 4 male process connection G1 4 Battery Change Battery Life When the battery starts weakening a low battery warning BAT LOW will appear in the upper left corner of the display Battery change Open the battery compartment and change the battery type CR 2430 The battery life is 1400 hours in normal measuring mode Ranges Calibration The factory setting of the Zero for the ranges 1 3 bar or 1 30 bar is at 0 bar absolute For sealed gauge pressure measurements activate ZERO SEt at ambient pressure Instruments with the ranges 0 300 bar or 0 700 bar are calibrated in a sealed gauge mode with 1 bar absolute pressure as a Zero reference SIKA Dr Siebert amp K hn GmbH amp Co KG Struthweg 7 9 34260 Kaufungen Germany 3 4 Tel 49 5605 803 0 Fax 49 5605 803 54 email info SIKA net web www SIKA net Digital precision reference test gauge Pressure medium fluids and
4. tting a new pressure unit mbar hPa gt Turn on the instrument by shortly pressing the SELECT key gt Wait for the instrument s measuring mode approx 3 seconds gt Press the SELECT key 3 times MANO appears gt Press ENTER ZERO SEt appears gt Press SELECT ZERO rES appears gt Press SELECT CONT on or CONT off appears gt Press SELECT BAR appears gt Press SELECT mbar hPa appears gt Press ENTER The new pressure unit is set The instrument returns to the measuring mode Display of the minimum pressure value When in the measuring mode Display Actual Pressure and Max value you may display the Min value for 5 seconds by shortly pressing the ENTER key Notes 1 The functions and units can also be called up by keeping the SELECT key depressed Releasing the key enables the displayed function or unit to be activated with the ENTER key 2 If the selected function or unit is not activated within 5 seconds with the ENTER key Reference Type D returns to the measuring mode without changing any settings 3 Turning Reference Type D on and off does not influence any of the previous settings 4 If the CONT on function is activated it is indicated with a flashing sign on the display 5 If a pressure can not be represented on the display OFL overflow or UFL underflow appears on the display 6 If the actual pressure goes beyond the measuring range the last valid pressure value

Download Pdf Manuals

image

Related Search

Related Contents

  Betriebsanleitung (Original) User Instructions  Benchtop Peristaltic Dispenser Peristaltische Schlauchpumpe  Hunter Fan 41787-01 Ventilation Hood User Manual  Rockford R300-4  

Copyright © All rights reserved.
Failed to retrieve file