1. Table 3 Revision History Table Date Revision Description March 2009 1 2 Fixed typo on page 6 and latest changes from Dell March 2009 1 1 Added Dell Logo November 2008 1 0 Initial Release Mellanox Technologies Rev 1 2 17 18 Appendix A Specifications Rev 1 2 Table 4 M3601Q Specification Data 16 internal backplane connectors Physical Power and Environmental Hx W x D 10 73 x 2 322 x 10 04 inches Maximum Power 152 W 272 54 x58 98 x 255 02 mm Dissipated Power 120W Weight 3 05 Kg fully configured Power through Mounting Vertically mounted rack connector 2 0 W per port Temperature 0 C to 40 C SerDes Speeds 10 20 40 Gb s per port Humidity 10 90 non condensing Altitude Connectors QSFP Shock 16 external QSFP connectors Vibration Protocol Support Regulatory Compliance InfiniBand QoS Management Auto Negotiation of 10Gb s 20Gb s or 40 Gb s 9 InfiniBand Virtual Lanes for all ports 8 Data transport lanes and 1 management lane Baseboard Performance and Device manage ment Agents for full InfiniBand In Band Man agement Safety EMC ENVIRONMENTAL US Canada cTUVus EU IEC60950 International CB USA FCC Class A Canada ICES Class A EU CE Mark EN55022 Class A EN55024 EN61000 3 2 EN61000 3 3 Japan VCCI Class A Korea RRL MIC Class A Australia New Zealand C Tick Class A EU IEC
2. Basic installation hot swapping components and hardware maintenance is covered in Installation and Basic Operation on page 8 The M3601Q switch has a Hot Swap controller and a PSOC Management IC Mellanox Technologies Rev 1 2 6 1 1 Rev 1 2 Figure 1 Switch Front Panel and Locking Mechanism Locking Mechanism Switch Status Lights InfiniBand Connectors InfiniBand connectivity has 16 QSFP connectors through the front panel The remaining 16 inter faces are through the AirMax Midplane Connector out the back of the switch Figure 1 shows the front 16 ports Each of the InfiniBand ports has two LEDs located next to the connector The green LED when lit indicates that a valid physical connection to the other system switch or HCA port exists The yel low LED when lit indicates that the Subnet Manager is running and a valid data link exists The yellow LED illuminates when the InfiniBand network is discovered over the physical link A valid data activity link without data transfer is designated by a constant yellow LED indication A valid data activity link with data transfer is designated by a blinking yellow LED indication If the LEDs are not active either the physical link or the logical link or both connections have not been estab lished Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual 1 2 7 Figure 2 Physical and Logical Link Indication LEDs LED Name
3. 60068 2 64 Random Vibration EU IEC 60068 2 29 Shocks Type I II EU IEC 60068 2 32 Fall Test Scalability and Performance Switching Performance Addressing Switching Capacity Simultaneous wire speed any port to any port 48K Unicast Addresses Max per Subnet 16K Multicast Addresses per Subnet 2 56 Tb s Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual Appendix B EMC Certification Statements B 1 FCC Statements USA Class A Statements 15 21 Statement Warning Changes or modifications to this equipment not expressly approved by the party responsi ble for compliance Mellanox Technologies could void the user s authority to operate the equipment 15 105 a Statement NOTE This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accor dance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense B 1 1 EN Stateme
4. 7171 BF 2E HAE PETE 717 9 21 BAA EE AS ARE A F Fr Bebe ve ax ol EE TUHAA dole 792032 2837 ve Uc Translation Class A Device This device is registered for EMC requirements for industrial use The seller or buyer should be aware of this If this type was sold or purchased by mistake it should be replaced with a res idential use type Rev 1 2 Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual Appendix C OSFP Interface 20 GND enD 19 21 Rx2n Rxin 18 gro Table 5 InfiniBand QSFP Connector Pinout 22 Rx2p Rx1p 17 23 16 GND GND Connector Connector 2 Ke 24 FA Re 15 Pin Number Pin Name Signal Description x4n x3n 25 Rx p Rx3p 14 1 GND Ground 26 GND GND 13 2 Tx2n Transmitter Inverted Data Input 3 Tx2 Transmitter Non Inverted Data Input 2r ModPrsL SDA 12 P p 28 11 4 GND Ground IntL SCL 29 10 5 Tx4n Transmitter Inverted Data Input VecTx Vec Rx 30 9 6 Tx4p Transmitter Non Inverted Data Input Vcc1 ResetL 8 7 GND Ground EP Mode Moesel 8 ModSelL Module Select 32 GND GND 7 F 9 ResetL Module Reset 34 De Bean 5 10 Vee Rx 3 3 V Power supply receiver Tx3n Tx4n A TE 35 GND GND 4 11 SCL 2 wire serial interface clock 36 Txip Tx2p 3 12 SDA 2 wire serial interface data 37 Ben Tx2n 2 13 GND Ground 38 GND GND 1 14 Rx3p Receiv
5. Check 0 0 Performance Counters Report 0 0 Partitions Check 0 0 IPOIB Subnets Check 0 0 Please see tmp ibdiagnet log for complete log I Done Run time was 1 seconds I Added 3 in band devices root mymach gt To list the discovered mst inband devices run mst status root mymach gt mst status MST modules MST PCI module loaded MST PCI configuration module loaded Inband devices dev mst CA MI dev mst SW MI dev mst SW MI 25418 sw005 HCA 1 lid 0x0001 47396 1 Lid 0x0011 48438 1 root mymach gt Rev 1 2 Lid 0x0003 Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual II Using the ibnetdiscover tool Run root mymach ibnetdiscover grep 00000006660abcd0 grep w Switch Switch 24 5 00000006660abcd0 MT48436 Infiniscale III Mellanox Technologies base port 0 lid 17 Imc 0 Note The resulting LID is given as a decimal number 4 Run mlxburn with the LID retrieved in step 3 above to perform the In Band burning operation Burn the InfiniScale IV switch root mymach gt mlxburn d dev mst SW_MT48438_lid 0x0003 fw fw IS4 mlx qq I Querying device I Using auto detected configuration file MTS3600Q 1UNC Al ini PSID MT 0C20110003 I Generating image WARNING Running quick query Skipping full image integrity checks Current FW version on flash 7 0 135 New FW version 7 0 138 Burning second FW
6. Connection Status Physical Link Green Off No Physical Link ON Physical Link Data Activity Yellow Blinking indicates Data Transfer Constant on indicates Link exists with no Data Transfer taking place Off with green LED lit indicates that the Subnet Manager may not be running Switch Status Lights The switch Status lights indicate whether the switch is receiving power from the chassis and the state of the switch Figure 3 Indicator LEDs The IO Module is on and gt D BEER LED can be blue or ready when both the blue and green LEDs are lit Table 2 IOM states and LED configurations amber A fault is indicated when the amber LED is blink ing See Table 2 LED Switch Status Indication Green Status e OFF OFF OFF ON OFF Boot in Progress D O C Switch not ready ON BLINKING BLUE The CMC is identifying D ea the newly installed switch Blinking Blue i O ON ON BLUE Switch is on and operating Normally ON ON or BLINKING Fault in System D C AMBER Self diagnosed OFF ON or BLINKING Fault in System D O AMBER CMC detected Mellanox Technologies Rev 1 2 8 2 1 Rev 1 2 Installation and Basic Operation Installation and initialization of the I O module are straightforward processes requiring attention to the normal mechanical power and thermal precautions for rack mounted equipment The I O mod ule does not req
7. image without signatures OK Restoring second signature OK I Image burn completed successfully Mellanox Technologies Rev 1 2 16 Troubleshooting s soon as a switch is plugged in make sure that the power LED comes on The power LED for the switch does not come on 1 Check that the chassis has power 2 Remove and reinstall the switch The status LED for the switch is blinking amber 1 remove the switch from the chassis and re insert it verify that the switch is all the way in the chassis and the lever is firmly closed 2 If the amber LED continues to blink replace the switch The link LED for the InfiniBand connector does not come on 1 Check that both ends of the cable are connected 2 Check that the locks on the ends are secured 3 Make sure that the latest FW version is installed on both the Mezzanine I O card and the switch 4 Make sure that at least one blade has a matching Mezzanine I O card installed to support data flow 5 If media adapters are used check that the all connections are good tight and secure The activity LED does not come on Check that the Subnet Manager has been started The power LED for the switch shuts off 1 Check that the there is adequate ventilation 2 Make sure that there is nothing blocking the front or rear ventilation openings of the chassis Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual Revision History
8. n ral il faut remplir la baie avec du mat riel de bas en haut gt 7 Installation du mat riel Ce mat riel ne doit tre install remplac ou entretenu que par du personnel form et qualifi gt Mellanox Technologies Rev 1 2 24 8 Elimination du mat riel L limination de ce mat riel doit s effectuer dans le respect de toutes les l gislations et r glementations nationales en vigueur 9 Codes lectriques locaux et nationaux Ce mat riel doit tre install dans le respect des codes lectriques locaux et nationaux Rev 1 2 Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual Appendix E Installation Sicherheitshinweise 1 Installationsanleitungen Lesen Sie alle Installationsanleitungen bevor Sie das Ger t an die Stromversorgung anschlie en 2 bertemperatur Dieses Ger t sollte nicht in einem Bereich mit einer Umgebungstemperatur ber der maximal empfohlenen Temperatur von 40 C 104 F betrieben werden Au erdem sollten mindestens 8 cm 3 in Freiraum um die Bel ftungs ffnungen sein um einen einwandfreien Luftstrom zu gew hrleisten gt 3 Stapeln des Chassis Das Chassis sollte nicht auf andere Ger te gestapelt werden Wenn das Chassis herunt erf llt kann es zu Verletzungen und Besch digungen an Ger ten f hren gt 4 Bei Gewitter Elektrische Gefahr Arbeiten Sie w hrend eines Gewitters und Blitzschlag nicht am Ge
9. switch LED is lit InfiniBand Cable Installation All cables can be inserted or removed with the unit power on To insert a cable press the connector into the port receptacle until the connector is firmly seated The green LED indicator accompanying each port will light when the physical connection is established that is when the unit is powered on and a cable is plugged into the port with a functioning port plugged into the other end of the con nector After plugging in a cable lock the connector using the latching mechanism particular to the cable vendor The yellow LED will light if the subnet manager is running non blinking indicating that no data is being transferred yet When a logical connection is made the yellow LED will blink signifying data is being transferred Mellanox Technologies Rev 1 2 12 To remove disengage the locks and slowly pull the connector away from the port receptacle Both LED indicators will turn off when the cable is unseated Care should be taken not to impede the air exhaust flow through the chassis Note Cable lengths should be used which allow for routing horizontally around to the side of the chassis before bending upward or downward in the rack Rev 1 2 Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual 3 3 1 3 2 Cluster Management and Firmware Network Management and Clustering Software Download and install on all nodes the Mellanox Ope
10. 3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual Appendix D Avertissements de s curit d installation 1 Instructions d installation Lisez toutes les instructions d installation avant de brancher le mat riel a la source d alimentation lectrique 2 Temp rature excessive Ce mat riel ne doit pas fonctionner dans une zone avec une temp rature ambiante d passant le maximum recommand de 40 C 104 F En outre pour garantir un bon coulement de lair laissez au moins 8 cm 3 pouces d espace libre autour des ouver tures de ventilation gt 3 Empilage du ch ssis Le ch ssis ne doit pas tre empil sur un autre mat riel Si le ch ssis tombe il peut pro voquer des blessures corporelles et des d gradations de biens gt 4 Orages dangers lectriques Pendant un orage il ne faut pas utiliser le mat riel et il ne faut pas brancher ou d brancher les c bles gt 5 Branchement debranchement des c bles InfiniBand en cuivre Les c bles InfiniBand en cuivre sont lourds et ne sont pas flexibles il faut donc faire tr s attention en les branchant et en les d branchant des connecteurs Consultez le fab ricant des c bles pour conna tre les mises en garde et les instructions sp ciales gt 6 Montage et entretien sur baie Lorsque ce produit est mont ou entretenu sur baie il faut prendre des pr cautions sp ciales pour s assurer que le syst me reste stable En g
11. Mellanox TECHNOLOGIES Third party information brought to you courtesy of Dell InfiniScale IV M3601Q 40Gb s InfiniBand Blade Switch I O Module for PowerEdge M Series User Manual PN M3601Q Rev 1 2 Mellanox Technologies 2 Rev 1 2 Copyright 2009 Mellanox Technologies Inc All Rights Reserved Mellanox Technologies ConnectX InfiniBlast InfiniBridge InfiniHost InfiniRISC InfiniScale and InfiniPCI are registered trademarks of Mellanox Technologies Ltd Virtual Protocol Interconnect is a trade mark of Mellanox Technologies Ltd Dell and the Dell logo are trademarks of Dell Inc All other marks and names mentioned herein may be trademarks of their respective companies InfiniScale IV M3601Q 40Gb s InfiniBand Blade Switch I O Module for PowerEdge M Series User Manual Document Number 3010 Mellanox Technologies Inc 350 Oakmead Parkway Suite 100 Sunnyvale CA 94085 U S A www Mellanox com Tel 408 970 3400 Fax 408 970 3403 Mellanox Technologies Ltd PO Box 586 Hermon Building Yokneam 20692 Israel Tel 972 4 909 7200 Fax 972 4 959 3245 NOTE THIS INFORMATION IS PROVIDED BY MELLANOX FOR INFORMATIONAL PURPOSES ONLY AND ANY EXPRESS OR IMPLIED WARRANTIES INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED IN NO EVENT SHALL MELLANOX BE LIABLE FOR ANY DIRECT INDIRECT INCIDENTAL SPECIAL EXEMPLARY OR CONSE
12. QUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES LOSS OF USE DATA OR PROFITS OR BUSINESS INTERRUPTION HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY WHETHER IN CONTRACT STRICT LIABILITY OR TORT INCLUDING NEGLI GENCE OR OTHERWISE ARISING IN ANY WAY OUT OF THE USE OF THIS HARDWARE EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual Contents Contents About this Manual Chapter 1 Overview 1 1 InfiniBand Connectors 1 2 Switch Status Lights Chapter 2 Installation and Basic Operation 2 1 Installation Safety Warnings 2 2 Mechanical Installation 2 2 1 Removing an Old Switch From the Chassis 2 2 2 Removing an I O Module Blank From the Chassis 2 2 3 Installing the Mellanox M3601Q Switch Into the Dell Chassis 2 3 Power Connections and Initial Power On 2 4 InfiniBand Cable Installation Chapter 3 Cluster Management and Firmware 3 1 Network Management and Clustering Software 3 2 Updating Firmware 3 2 1 Instructions for Reprogramming Over the InfiniBand Network Chapter 4 Troubleshooting Revision History Appendix A Specifications Appendix B EMC Certification Statements Appendix C QSFP Interface Appendix D Avertissements de securite d installation Appendix E Installation Sicherheitshinweise Mellanox Technologies Rev 1 2 About this Manual This manual describes the installation
13. and basic use of the InfiniScale IV M3601Q 40Gb s Infini Band blade switch I O module for PowerEdge M Series Intended Audience This manual is intended for users and system administrators responsible for installing and setting up the switch platforms listed above The manual assumes familiarity with the InfiniBand Architecture Specification Related Documentation The documentation set accompanying the Mellanox M3601Q includes the following Table 1 Reference Documents InfiniBand Architecture Specification Vol ume I Release 1 2 1 and Volume 2 release 1 2 1 InfiniBand architecture specification descriptions Mellanox Firmware Tools MFT The MFT Mellanox Firmware Tools package is a set of firmware tools The manual User s Manual supplied with this package provides an overview of the firmware its installation and Document 2329 replacement The MFT can be downloaded with its documentation at http www mellanox com gt Downloads gt Firmware Tools Online Resources e Mellanox Technologies Web pages http www mellanox com e Dell Support Web pages http support dell com Conventions Throughout this manual the name M3601Q and the terms switch I O module and IOM are used to describe the M3601Q 40Gb s InfiniBand blade switch I O module unless explicitly indicated oth erwise Rev 1 2 Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual 1 Overvie
14. and connected to a its corresponding fabric the ConnectX Mezzanine I O card must be installed in the corresponding fabric You must install a module in slots B1 C1 before installing a module in slots B2 C2 Removing an Old Switch From the Chassis 1 Remove any locking cables or screws that secure the old switch into the chassis 2 Disconnect all of the InfiniBand cables from the front of the switch to be removed 3 Unlock the switch from the chassis by pushing the red latch release button 4 Pull the locking arm down to a position perpendicular to the front of the chassis 5 Pull the switch out of the chassis using the locking arm Install either a new switch or an I O Module Blank within one minute Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual 11 2 2 2 Removing an I O Module Blank From the Chassis 2 2 3 2 3 2 4 1 Unlock the I O Module Blank by pushing the red latch release button 2 Pull the locking arm down to a position perpendicular to the front of the chassis 3 Pull the I O Module Blank out of the chassis using the locking arm 4 Install either a new switch or reinstall a blank IOM within one minute Installing the Mellanox M3601Q Switch Into the Dell Chassis Note Make sure the rack is stable on a solid floor and that the rack is filled from the bottom up This will keep the center of gravity as low as possible reducing risk of tipping Note The M3601Q I O modul
15. detached from the connectors Refer to the cable manufacturer for special warnings and instructions 6 Rack Mounting and Servicing When this product is mounted or serviced in a rack special precautions must be taken to ensure that the system remains stable In general you should fill the rack with equipment starting from the bottom to the top 7 Equipment Installation This equipment should be installed replaced or serviced only by trained and qualified personnel 8 Equipment Disposal Disposal of this equipment should be in accordance to all national laws and regulations 9 Local and National Electrical Codes This equipment should be installed in compliance with local and national electrical AN codes Mellanox Technologies Rev 1 2 10 2 2 2 2 1 Rev 1 2 Mechanical Installation These switches are hot pluggable It is not necessary to power down the Dell Chassis to install a new switch or to replace an old switch with a new one Figure 4 Rear View of the Dell PowerEdge M1000e Chassis Latch Release Buttons Locking Arms Channel 1 slots Channel 2 slots Al BI CI C2 B2 A2 Note M3601Q blades are not allowed in the Fabric A slots The M3601Q IOM occupies both Fabric B and Fabric C slots and connects to the Fabric C mid plane The ConnectX Mezzanine I O card must be installed in the Fabric C location on the server blade to support data flow This does NOT apply to DDR since the switch is installed in a single slot
16. e occupies both Fabric B and Fabric C slots and connects to the Fabric C mid plane The ConnectX I O card must be installed in the Fabric C location on the server blade to support data flow You must install a module in slots B1 C1 before installing a module in slots B2 C2 Refer to the Dell PowerEdge M1000e Hardware Owners Manual for more information 1 Follow the instructions in Section 2 2 1 or Section 2 2 2 to remove an old switch or an I O Mod ule Blank On the new switch push the red latch release button Pull the lever forward until the lever is perpendicular to the front panel Push the switch into the slot until the latching mechanism is against the bar Ane D Push the lever on the latching mechanism up making sure that the latching mechanism catches the locking bar The lever should now be parallel to the front panel 6 Check the indicator lights to make sure the switch has power The rack mounting is designed to fit the PowerEdge Chassis Take precautions to guarantee proper ventilation for air intake at the front of the chassis and exhaust at the rear in order to maintain good airflow at ambient temperature Cable routing in partic ular should not impede the air exhaust from the chassis Power Connections and Initial Power On Caution The I O module will automatically power up when AC power is applied There is no power switch Immediately upon closing the latching mechanism check to make sure that the green
17. er Non Inverted Data Output 15 Rx3n Receiver Inverted Data Output 16 GND Ground 17 Rxlp Receiver Non Inverted Data Output 18 RxIn Receiver Inverted Data Output 19 GND Ground 20 GND Ground 21 Rx2n Receiver Inverted Data Output 3 22 Rx2p Receiver Non Inverted Data Output 3 23 GND Ground 24 Rx4n Receiver Inverted Data Output 3 25 Rx4p Receiver Non Inverted Data Output 3 26 GND Ground 27 ModPrsL Module Present 28 IntL Interrupt 29 Vcc Tx 3 3 V Power supply transmitter 30 Vcc 1 3 3 V Power Supply 31 LPMode Low Power Mode 32 GND Ground 33 Tx3p Transmitter Non Inverted Data Input 34 Tx3n Transmitter Inverted Data Input 35 GND Ground 36 Txlp Transmitter Non Inverted Data Input 37 TxIn Transmitter Inverted Data Input 38 GND Ground Mellanox Technologies Rev 1 2 22 Figure 5 Pinout Looking Into the Rear of the Connector and the Front of the Cage 18 35 Top View into Rear of Connector GND LPMode GND TX2n TX2p GND TX4n TX4p GND ModSelk ResetL VecRx SCL SDA GND Top 18 35 RX3p RX3n GND RX1p RX1n GND VG GND View into Front of Cage an UZXY dzXx4 AND UPXH dyXH AND TS1dPOW qul X199A LIDA spoWd1 AND dexL UEXL S GLXL WXL N gt 61 op N CRE 1 AND or di XH AND UEXH dexx AND vas 10S XH99A Tesex I9SPOWN AND dpx 1 UpXL AND dzXL UZXL AND Mellanox Technologies Rev 1 2 M
18. nFabric software package for Linux Windows or other operating systems from the Mellanox software website http www mellanox com gt Downloads gt InfiniBand SW Drivers This software package provides connectivity for server and storage systems utilizing High Perfor mance Computing HPC or enterprise data center EDC applications across an InfiniBand fabric It also provides a Subnet Manager for simple network configuration and network administration and diagnostic tools for network management Updating Firmware The switch is delivered with the latest Firmware available at the time of production New firmware versions will be posted on the Mellanox firmware download page Firmware can be updated in band using the Mellanox Firmware Tools MFT You will need the Mellanox Firmware Tools package available in MLNX_OFED to update firm ware for this switch It also can be downloaded from http www mellanox com gt Downloads gt Firmware Tools The latest firmware can be found at http www mellanox com gt Support gt Dell 3 2 1 Instructions for Reprogramming Over the InfiniBand Network To update an MT48436 InfiniScale IV switch device having a specific GUID for example 0x00000006660abcd0 or LID the following are the recommended steps to update the device firmware 1 Make sure all subnet ports are in the active state One way to check this is to run opensm the Subnet Manager root mymach gt etc init d opensmd sta
19. nts Europe EN55022 Class A Statement Warning This is a class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures B 1 2 ICES Statements Canada Class A Statement This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme a la norme NMB 003 du Canada B 1 3 VCCI Statements Japan Class A Statement CORBIS F ALEREFERES BER MMET VCCI ORK BDC TFAZATRRMRECT NE RER CHEATS CBR MBSR FCEPHVET INGA ER ED EN i KR EET BLIRKENZZLENBUET Mellanox Technologies Rev 1 2 20 Translation This is a Class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment VCCI If this equipment is used in a domestic environment radio interference may occur in which case the user may be required to take corrective actions B 1 4 MIC Certification Korea Korea s Regulation for Certification of Information and Communication Equipment requires EMC test ing and certification for many electronic products Korean EMC certifications are issued by Radio Research Laboratory RRL which is organized under the Ministry of Information and Communications MIC EMC testing includes electromagnetic emissions EMI and susceptibility EMS Certified equip ment is labeled with the MIC mark and certification number
20. r t schlie en Sie keine Kabel an oder ab gt 5 Anschlie en Trennen von InfiniBand Kupferkabel InfiniBand Kupferkabel sind schwer und nicht flexible Deshalb m ssen sie vorsichtig an die Anschl sse angebracht bzw davon getrennt werden Lesen Sie die speziellen Warnungen und Anleitungen des Kabelherstellers gt 6 Rack Montage und Wartung Wenn dieses Produkt in einem Rack montiert oder gewartet wird sind besondere Vor sichtsma nahmen zu ergreifen um die Stabilit t des Systems zu gew hrleisten Im Allgemeinen sollten Sie das Gestell von unten nach oben mit Ger ten f llen gt 7 Ger teinstallation Diese Ger t sollte nur von geschultem und qualifiziertem Personal installiert ausge tauscht oder gewartet werden gt Mellanox Technologies Rev 1 2 26 8 Ger teentsorgung Die Entsorgung dieses Ger ts sollte unter Beachtung aller nationalen Gesetze Bestim mungen erfolgen 9 Regionale und nationale elektrische Bestimmungen Dieses Ger t sollte unter Beachtung der regionalen und nationalen elektrischen Bestimmungen installiert werden Rev 1 2 Mellanox Technologies
21. rt opensm start OK 2 Make sure the local ports are active by running ibv_devinfo 3 Obtain the device LID There are two ways to do that I Using the mst ib add command The mst ib add runs the ibdiagnet tool to discover the InfiniBand fabric and then lists the discovered IB nodes as an mst device under dev mst directory These devices can be used for access by other MFT tools root mymach gt mst ib add I Running ibdiagnet to discover the fabric Loading IBDIAGNET from usr local lib ibdiagnet1 2 W Topology file is not specified Reports regarding cluster links will use direct routes Loading IBDM from usr local lib ibdml 2 Mellanox Technologies Rev 1 2 14 I Using port 1 as the local port I Discovering 3 nodes 2 Switches amp 1 CA s discovered I I Bad Guids LIDs Info I I skip option set no report will be issued I I Links With Logical State INIT I I skip option set no report will be issued I I PM Counters Info E I skip option set no report will be issued I I Fabric Partitions Report see ibdiagnet pkey for a full hosts list E I skip option set no report will be issued T I IPoIB Subnets Check T 32 I skip option set no report will be issued E I Bad Links Info I I No bad link were found I Stages Status Report STAGE Errors Warnings Bad GUIDs LIDs Check 0 0 Link State Active
22. uire any programming or configuration to operate as a basic InfiniBand switch and includes all of the necessary functionality to operate with external standard InfiniBand Subnet Management software This section describes the installation process and basic operation of the I O module Please first read the warnings sub section carefully before carrying on with installation procedures Suitable electrical mechanical and fire enclosure shall be provided by the end user Installation Safety Warnings 1 Installation Instructions Read all installation instructions before connecting the equipment to the power source 2 Over temperature This equipment should not be operated in an area with an ambient temperature exceed ing the maximum recommended 40 C 104 F Moreover to guarantee proper air flow allow at least 8cm 3 inches of clearance around the ventilation openings 3 Stacking the Chassis The chassis should not be stacked on any other equipment If the chassis falls it can cause bodily injury and equipment damage 4 During Lightning Electrical Hazard During periods of lightning activity do not work on the equipment or connect or discon nect cables gt Mellanox Technologies M3601Q 40Gb s InfiniBand Blade Switch I O Module User Manual 5 Copper InfiniBand Cable Connecting Disconnecting Copper InfiniBand cables are heavy and not flexible as such they should be carefully attached to or
23. w The InfiniScale IV M3601Q 40Gb s InfiniBand blade switch I O module for PowerEdge M Series provides a high bandwidth low latency fabric for Enterprise Data Centers High Perfor mance Computing and Embedded environments Based on the fourth generation InfiniScale IV InfiniBand switch device this I O module IOM delivers up to 40Gb s full bisectional bandwidth per port When used in conjunction with ConnectX InfiniBand dual port Mezzanine I O cards clustered data bases parallelized applications and transactional services applications will achieve significant performance improvements resulting in reduced completion time and lower cost per operation The I O module comes pre installed with all necessary firmware and configured for standard oper ation within an InfiniBand fabric and requires an InfiniBand compliant Subnet Manager running from one of the hosts All that is required for normal operation is to follow the usual precautions for installation and connection from the switch to the HCAs or other switches Once connected the Subnet Management software automatically configures and begins utilizing the switch It is recommended that Mellanox OpenFabrics software package be installed on all nodes con nected to the M3601Q The software package provides a subnet manager and network management tools as well as connectivity software for servers and storage and is available on the Mellanox web site See Chapter 3 for more information

Download Pdf Manuals