Home
Manual - Northern Tool + Equipment
Contents
1. For the set point temperature use the top arrow button A and the down arrow button Y to adjust the setting between 10 to 35 C 50 to 95 F When heater is on four gradated lines indicate the power level on the left side of the display For timer mode boost heating use the hour glass button located on the left side of display Press once to activate this mode and to see the remaining time flashing min is now displayed in the bottom right corner Display will stop flash ing after five 5 seconds While the remaining time flashes press again the button on the left to set the minutes to 5 10 15 20 25 or 30 If display does not flash any more press again the button on the left to turn off the timer Whenever needed in the timer mode use the arrows located on the right side to increase or decrease remaining time When in the timer mode ambient temperature is not displayed To turn on and off the night light use the button located underneath The night light is a low consuming device due to its technology NOTICE When starting up the heater for the first time some smoke will come out of the louvers this is totally normal and will stop after a few minutes of use Also under normal use the heater may become hot SAFETY To avoid problems do not allow water in and make sure no splash get inside heater IMPORTANT DO NOT USE HEATER AS A TOWEL DRYER DO NOT COVER HEATER WHEN POWERED ON MAINTENANCE Clea
2. ovettet 180 3 Avenue L Islet Qu bec GOR 2CO CANADA Telephone 418 247 3947 1 800 463 7043 Fax 418 247 7801 www ouellet com INSTALLATION INSTRUCTIONS for Bathroom Heater OHY Series INSTALLATION MUST BE ACCOMPLISHED BY A QUALIFIED TECHNICIAN Ln RISK OF ELECTRIC SHOCK AN WARNING Read Carefully These instructions contain necessary information for the proper installation use and efficient operation of the heater Carefully read these instructions before installation operation of the heater Failure to adhere to the instructions could result in fire electric shock serious personal injury death or property damage Save these instructions and review frequently for continu ing safe operation and instruction of future users if nec essary ATTENTION Carefully read these instructions before installation Never paint the heater Never alter the heater Never install the heater on a wall covered with vinyl Do not use outdoors This heater may become hot when in use To avoid DRONA 7 8 9 burns do not touch hot surfaces of the heater with bare skin Keep all combustible materials away from top and front of heater furniture pillows bedding paper clothing bath towel bath robe drapes etc Heater should not be blocked in any manner Install heater in position shown in installation figures of these instructions Allow 102 mm 4 in minimum clearance below heater 10 Allow 25 m
3. 200702 00 ovettet 180 3 Avenue L Islet Qu bec GOR 2CO CANADA Telephone 418 247 3947 1 800 463 7043 Fax 418 247 7801 www ouellet com USER MANUAL OHY SERIES You have just purchased a highly sophisticated heater unit establishing new standards in design and precision while being filled with industry first characteristics This heater will bring you warmth and piece of mind for the years to come If you have any question concerning your unit do not hesitate to communicate with our customer service department Hybrid Series is a convection and forced air wall heater of great power including an integrated electronic thermostat a completely quiet timer a night light with integrated switch a contemporary look and a user friendly interface The thermos tat manages when the fan needs to start in order to keep a constant temperature Please read and understand this user guide completely before using the heater Failing to follow this user guide and if the heater is not installed according to installation instruc tions included in the box the manufacturer will not be liable for the warranty HEATER OPERATION Once the unit is powered up the blue display indicates the ambient temperature in degree Celsius C or Fahrenheit F To change the units from C to F or vice versa press the two buttons with arrow signs on the right side of display simultaneously for two 2 seconds x
4. in the USER GUIDE provided with these instructions Any other use not recommended by the manufacturer may cause fire electric shock or injury to persons 23 Refer to the USER GUIDE for servicing and troubleshooting tips on this heater 24 AMERICAN VERSION ONLY This heater includes a visual alarm red light to warn parts of the heater are getting excessively hot If the light turns on immediately turn the heater off and inspect for any objects on or adjacent to the heater that may cause high temperatures If nothing seems to obstruct air inlet have heater inspected by a qualified person DO NOT OPERATE THE HEATER WITH THE ALARM LIGHT ON WARRANTY Ouellet Canada Inc warrants the electric heating element of the OHY Series for a five 5 year period and the component parts against defects in material and workmanship for a two 2 year period following the date of purchase under normal use and service when proof of purchase of such is provided to the manufacturer The obligation of Ouellet Canada Inc under the terms of this warranty will be to supply a new unit and this omits the manufacturer to bear the installation costs or other secondary charges linked to replacing the unit or the component part s SURFACE WALL MOUNTING WITH OR WITHOUT OHY CM 12 305 mm Recommand 4 102 mm Minimum Keep a clearance of 1219 mm 48 in minimum in front of heater and 25 mm 1 in to any walls SURFACE W
5. to supply a new unit and this omits the manufacturer to bear the installation costs or other secondary charges linked to replacing the unit or the component part s INS119 200702 00 screws carefully with low torque to avoid stripping the threads Pay attention to labels indicating the orientation of each component ASSEMBLY OF OHY CM OPTION 4 Insert heater s enclosure within the trim sleeve as shown and use the four 4 screws provided in the trim sleeve O UJ E L L ET packing to assemble both parts together Tighten these 180 3 Avenue L Islet Qu bec GOR 2CO CANADA Telephone 418 247 3947 1 800 463 7043 Fax 418 247 7801 www ouellet com 12 305 mm g Recommended 4 102 mm Minimum Keep a clearance of 1219 mm 48 in minimum in front of heater and 25 mm 1 in to any walls ASSEMBLY STEPS FOR CAST TRIM SLEEVE OHY CM 5 Fix the assembly to the wall as shown using the holes OPTION indicated as item B in the figure As needed use the four 1 In order to proceed to the installation of this option a 4 anchors for gypsum provided within packing DO NOT OHY unit heater must be purchased separately Remove FIX THE HEATER WITH THE HOLES MENTIONNED IN front cover by unscrewing both screws at the bottom STEP 2 USED TO SCREW THE INSIDE MODULE INSTALLATION INSTRUCTIONS 2 Remove the inside module to which the fan is fixed by THIS MAY CAUSE THE HEATER TO MALFUNCTION loo
6. 4 in knock outs item A in the figure located on each side of enclosure that will be used to fix it to the wall Run the power cable inside the enclosure 6 Fix the enclosure by using the 6 35 mm 1 4 in knock outs or the holes on the back indicated as item B in the figure to firmly fix the heater with provided screws two additional longer screws are provided to help in case of larger framing DO NOT FIX THE HEATER WITH THE HOLES MENTIONNED IN STEP 4 USED TO SCREW THE INSIDE MODULE THIS MAY CAUSE THE HEATER TO MALFUNCTION KOE 7 8 7 Put inside module back and tighten the four 4 RED screws 8 Wire the heater according to national and local codes and along instructions marked on heater P2IN Of0 obo L2 N P10 tOL4 Option M Disconnect OHY1502 2000 OHYU1502 2000 Load 2 LOAD Loapa FANT Pi Hi Limit ma 250 F 121 C Ve Power Base Load 2 1000W 240V 500W 120V Load 1 1000W 240V 1000W 120V OHYU only 9 Replace junction box cover and remove the front cover from its protective bag 10 Fix the plastic connector on the outlet located in the top of the front cover 11 Put front cover back making sure the cable linking the cover with the heater does not get stuck Test the heater to insure control works properly Keep this instruction pamphlet for the user INS101
7. ALL MOUNTING STEPS 1 To install the optional cast trim sleeve refer to instructions provided with option OHY CM Heater may be surface mounted without the optional cast trim sleeve Recommended installation height is 305 mm 12 in below heater Use provided template to locate positioning of the supply wire 2 Follow steps 2 to 11 of RECESSED WALL MOUNTING Pat No Des D571 906 S RECESSED WALL MOUNTING 2 3 4 70 mm 12 305 mm Recommended 4 102 mm Minimum Keep a clearance of 1219 mm 48 in minimum in front of heater and 25 mm 1 in to any walls RECESSED WALL MOUNTING STEPS 1 Make a hole within the wall at least 70 mm 2 3 4 in of depth The hole must be 473 mm 18 5 8 in by 340 mm 13 3 8 in use the template provided with the heater CAUTION HOLE MUST BE CUT PRECISELY 2 Remove front cover by unscrewing both screws at the bottom 3 Remove the junction box cover by unscrewing the screw Note the plastic connector secured inside the junction box will be connected outside the box once the heater is fully installed This connector links the enclosure with the display located on the front cover 4 Remove the inside module to which the fan is fixed by loosening the four 4 RED screws 5 Use the appropriate knock out hole KOE 7 8 in within the junction box as well as the 6 35 mm 1
8. m 1 in minimum clearance between sides of heater and any adjacent walls 11 Allow 1219 mm 48 in minimum in front of heater 12 Extreme caution is necessary when any heater is used by or near children or invalids and whenever the heater is left operating and unattended 13 Use intended holes in enclosure to secure heater in place as specified in these instructions 14 To avoid electric shock disconnect all power to heater at the main service panel before installation wiring or servicing and replace front cover of heater before putting the power back 15 Use power supply wire suitable for at least 90 C 194 F 16 All wiring must be done in accordance with the national and local electrical codes and the heater must be grounded 17 A incorrectly installed heater may be permanently damaged and present a risk of fire or electric shock Required minimal clearances must be observed along with theses instructions Heater must be tightly fixed to the building s framing 18 Do not install heater in vapor or shower bathrooms nor in places where it will be exposed to a high level of humidity or vapor for a long period 19 Make sure applied voltage is suitable for rating of heater 20 Dot not insert or allow foreign objects to enter any ventilation opening as this may cause electric shock short circuit fire or damage to heater 21 Do not block air inlet or outlet in any manner 22 Use heater only as described
9. n heater s interior on a regular basis to remove dust Clean front grills as dust may accumulate due to the impor tant air flow DISCONNECT POWER BEFORE CLEANING AND SERVICING REPLACE FRONT COVER BEFORE PUTTING POWER BACK TROUBLESHOOTING PROBLEMS TIPS Make sure front of heater has at least 1219 mm 48 in of clearance and is free of any objects Heater stops working in timer mode boost mode Wait for a while that temperature stabi lizes This thermostat uses proportional integral adaptive technology temperature will remain precise except when important cold or hot air flows occur Fan operation as well as room recognition have to be considered and may influenced precision of temperature readings Displayed temperature differs from ambient temperature Make sure voltage applied is appropriate 120V or 240V depending on model and that interior of heater is free of dust blocking heating wires Interior of heater glows red Grills are getting darker Clean grills using water and mild soap WARRANTY Ouellet Canada Inc warrants the electric heating element of the OHY Series for a five 5 year period and the component parts against defects in material and workmanship for a two 2 year period following the date of purchase under normal use and service when proof of purchase of such s provided to the manufacturer The obligation of Ouellet Canada Inc under the terms of this warranty will be
10. r the instalation costs or other secondary charges linked to replacing the unit or the component part s ATTENTION Carefully read these instructions before installation Do not use heater as a towel dryer stand or shelf Do not cover heater Disconnect power before cleaning or servicing and replace front cover before putting power back PONS KOE 7 8 INS111 200702 00
11. sening the four 4 RED screws FOR CAST TRIM SLEEVE OHY CM OPTION AN RISK OF ELECTRIC SHOCK AN WARNING Read Carefully These instructions contain necessary Information for the proper installation use and efficient operation of the heater Carefully read these instructions before installation operation of the heater Failure to adhere to the instructions could result in fire electric shock serious personal injury death or property damage Save these instructions and review frequently for conti nuing safe operation and instruction of future users if ne cessaly Failing to follow these guidelines and if the 3 Remove all 4 76 mm 3 16 in knock outs 6 Proceed with heater installation as described in the heater is not installed according to installation instructions item C in the figure heater s instructions provided with the latter Included in the box the manufacturer could not be held responsible for the warranty WARRANTY Ouellet Canada Inc warrants the electric heating element of the OHY Series for a five 5 year period and the component parts against defects in material and workmanship for a two 2 year period following the date of purchase under normal use and service when proof of purchase of such is provided to the manufacturer The obligation of Ouellet Canada Inc under the terms of this warranty will be to supply a new unit and this omits the manufacturer to bea
Download Pdf Manuals
Related Search
Related Contents
Seguro de Electrónicos RDMODGSM-TV Panasonic KX-TDA6181X 16-Port Analogue Trunk Card Service MANUEL D`INSTRUCTIONS POUR AFFICHEURS SÉRIE JVC AV-21QS5SE User's Manual Copyright © All rights reserved.
Failed to retrieve file