Home
electronic control box, 3 functions 20-0243
Contents
1. X1 in OFF position 20 minutes after water falls below water level sensor blower starts on output B and runs for 2 minutes to clean air channels During dry blowing the LED for blower flashes Pairing of wireless remote controller 25 2600 When using the optional remote controller for the first time remote and receiver must be paired It is required that power is connected to the control box during the pairing Press the red button marked Remote in the control box Within 15 seconds the blower button on the remote control must be pressed The pairing has now been com pleted Connection diagram 1 2 3 X1 X2 X3 X4 e Jyll z Remote OFF lo 2 A G Red LED Grey Z Brown am TRI RL1 RL2 RL3 M wie 2 Green LED lt Yellow GND Blue e LN UN U N UN Mains A B C 2 8 ELEKTRONISCHE STEUERUNG 3 FUNKTIONEN 20 0243 Technische Daten Nennspannung 230 V 50 60 Hz einphasig Nennleistung 3680 W Nennstrom 16 A Die Ausg nge A B C und D k nnen individuell mit bis zu max 3680 W jeweils 16 A belastet werden Die Gesamtsumme der Last darf jedoch Nennleistung und Nennstrom nicht bersteigen Abmessungen Gewicht 0 5 kg Lange 180 mm Breite 105 mm Tiefe 75 mm Betriebsstemperatur 0 bis 50 C Lagerungstemperatur 20 bis 50 C Baia Wichtig Dieses Kontrollger t ist nicht f r medizinische Zwecke einsetzbar Beachten sie die Anweisungen f r Installation und Anschluss Wir behalten u
2. x J zu z By Faites passer le c ble par A 2 Faites passer le cable par B et C B se trouve normalement l int rieur de C 8 Serrez suffisamment A sur C l aide d un outil 4 Montez les cosses rectangulaire et il sur les extr mit s du c ble le cas ch ant BOITIER DE COMMANDE ELECTRONIQUE 3 FONCTIONS 20 0243 C blage 1 La sonde de niveau d eau 25 0211 5 est raccord e au connecteur identifi par LEVEL 2 Le bouton trifonction est connect aux bornes a vis identifi es par TOUCH 3 Lapompe ou similaire est raccord e a la borne embrochable identifi e par A et au besoin a la terre 4 5 l Le blower ou similaire est raccord la borne embrochable identifi e par B et au besoin la terre Le projecteur immerg ou similaire est raccord la borne embrochable identifi e par C et au besoin la terre 6 Le bo tier lectronique est raccord au secteur via les bornes embrochables identifi es par MAINS et la terre R glage des cavaliers Cavalier Fonction ON OFF X1 Niveau d eau soufflage Un niveau d eau correct est Fonctionnement ind pendant du niveau sortie B requis pour l activation d eau Programme de soufflage sec actif x2 Niveau d eau sortie C Un niveau d eau correct est Fonctionnement ind pendant du niveau requis pour l activation d eau X3 Minuterie sortie C Minuterie de 30 minutes Pas de minuterie X4 Aucune fonction N
3. A N A Description fonctionnelle La baignoire est remplie d eau jusqu couvrir au moins la moiti de la sonde ce qui permet le fonctionnement En appuyant sur le bouton la pompe ou tout appareil connect d marre comme l indique la LED du bouton Lorsque le cavalier X3 est en position ON une minuterie de 30 minutes est activ e Lorsque le cavalier X3 est en position OFF la minuterie est d sactiv e Programme de soufflage sec X1 en position OFF Vingt minutes apr s que l eau a chut sous la sonde de niveau d eau le blower d marre sur la sortie B et fonc tionne pendant 2 minutes pour nettoyer les conduits d air Pendant le soufflage sec la LED du blower clignote Appariement de la t l commande sans fil 25 2600 Avant la premi re utilisation de la t l commande en option la t l commande et le r cepteur doivent tre appa ri s Le bo tier lectronique doit tre sous tension pendant cette op ration Appuyez sur le bouton rouge marqu Remote du bo tier lectronique Dans les 15 secondes vous devrez appuyer sur le bouton du blower sur la t l commande L appariement est termin Sch ma de raccordement 1 2 3 K N SS X1 X2 X3 X4 e Hit 5 Remote OFF 2 Rouge LED Gris CZ Brun 2 m TRI RL1 RL2 RL3 ME pate Z Vert LED lt Jaune GND Bleu o LN UN U N U N Mains A B C Bydreair E ELEKTRONISK KONTROL BOKS 3 FUNKTION 20 0243 Specifikationer M rkesp ndi
4. Position ON wird eine 30 Minuten Zeitschaltuhr aktiviert Die Zeitschaltuhr ist au er Betrieb wenn Jumper X3 auf OFF steht Trockengebl seprogramm X1 in Position OFF 20 Minuten nachdem das Wasser unterhalb des Wasserstandssensors gefallen ist schaltet sich das Gebl se ein Ausgang B und l uft 2 Minuten lang um die Luftkan le zu reinigen Dies wird durch die LED Leuchte des Gebl ses angezeigt Codierung der kabellosen Fernbedienung 25 2600 Vor der Inbetriebnahme der zus tzlich erh ltlichen Fernbedienung m ssen Fernbedienung und Empf nger Receiver aufeinander abgestimmt werden Hierf r muss die Kontrollbox an die Stromversorgung angeschlossen sein Bet tigen Sie den roten Schalter an der Kontrollbox der mit Remote gekennzeichnet ist Innerhalb von 15 Sekunden muss nun der Schalter f r das Gebl se gedr ckt werden Die Codierung ist hiermit erfolgt Anschluss Diagramm 1 2 3 X1 X2 X3 X4 e titi Remote OFF Oo 2 Rot LED Y Grau 9 Braun TRI RL1 RL2 RL e Weiss Z Grin A LED lt Gelb GND Blau e LN UNUNUN Mains A B C Fr _ 4 8 vdreAir L BOITIER DE COMMANDE ELECTRONIQUE 3 FONCTIONS 20 0243 Sp cifications Tension nominale 230 V 50 60 Hz monophas Puissance nominale 3680 W Intensit nominale 16 A Il est possible de charger les sorties A et B de mani re individuelle jusqu 3 680 W 16 A chacune Toutefois la somme totale des charges ne peut pas d pa
5. skal veere tilsluttet styringen under denne operation Parringen foregar ved at trykke pa den rade knap i boksen meer ket Remote Indenfor 15 sekunder trykker man pa bleesertasten pa fjernbetjeningen Parringen er nu fuldf rt Tilslutningsdiagram TEADE X1 X2 X3 X4 e 111 a Remote OFF 2 g R d LED Gra CZ 7 Brun TR1 RL1 RL2 RL3 A LED Hvid 2 Gran LED lt Gul GND Bl o L N U N U N U N Mains A B C 8 8
6. 11 5 wird mit dem Anschluss LEVEL verbunden 2 Der Multifunktionsschalter wird an die Schraubanschl sse mit der Aufschrift TOUCH angeschlossen 3 Pumpe oder Vergleichbares wird an die mit A gekennzeichneten Anschlussklemmen angeschlossen und sofern n tig an die Erdung 4 Gebl se oder Vergleichbares wird an die mit B gekennzeichneten Anschlussklemmen angeschlossen und sofern n tig an die Erdung 5 Unterwasserlicht oder Vergleichbares wird an die mit C gekennzeichneten Anschlussklemmen angeschlossen und sofern n tig an die Erdung 6 Das Kontrollgerat wird Uber die mit MAINS gekennzeichneten Anschlussklemmen an die Stromversorgung und an die Erdung angeschlossen Jumper Einstellungen Jumper Funktion ON AN OFF AUS X1 Wasserstand Trocken F r die Aktivierung ist die richtige en a gebl se Ausgang B Wasserstandsh he erforderlich Aktiv i 9 prog X2 Wasserstand Ausgang F r die Aktivierung ist die richtige Funktionsf hig unabh ngig vom C Wasserstandsh he erforderlich Wasserstand X3 Zeitschaltuhr C 30 Minuten Zeitschaltuhr Keine Zeitschaltuhr X4 Keine Funktion N A N A Funktionsbeschreibung Die Bedienung ist nur m glich wenn die Wanne soweit gef llt ist dass mindestens die H lfte des Sensors bedeckt ist Durch Bet tigung der Taste wird die Pumpe oder irgendein angeschlossenes Bauteil in Betrieb genommen Dies wird durch eine LED Leuchte auf der Taste angezeigt Ist Jumper X3 in
7. ELECTRONIC CONTROL BOX 3 FUNCTIONS 20 0243 Specifications Rated voltage 230 V 50 60 Hz single phase Rated power 3680 W Rated current 16 A The outlets A B and C can individually be loaded with up to max 3680W 16A each However the total sum of the loads must not exceed the rated power and current Dimensions amp temperature Weight 0 5 kg Length 180 mm Width 105 mm Depth 75mm Operating temperature 0 to 50 C Storage temperature 20 to 50 C BEE Important This control box is not suitable for medical use Follow the directions for installation and connection We reserve the right to change the product and the specification without notice Safety rules Locate the box in a dry area with good ventilation The box must be situated at least 3 cm above the ground floor Before cleaning servicing exchanging of parts or accessories or checking up on various disturbances the mains have to be cut off Make sure that there are no unconnected wires and cables inside the box Cables and wires must be as short as possible inside and outside the box The box is protection Class I It has to be connected with cables according to the instructions from EN 60335 1 and EN 60335 2 60 It is recommended that you consult a state registered electrician The supply cable has to be minimum type HO5VV F 3G1 5 mm Keep at all time minimum 20 mm distance between high and low power cables In order to separate the box from the m
8. ains you must install a suitable ground fault circuit interrupter with at least 3 mm break distance on each terminal in the present electrical installation The mounting is to be made in such a way that it is not possible to touch the electric parts The electric parts have to be mounted in such a way that they cannot fall into the bathtub Instruments of Class must be connected to a permanent installation Be aware that some countries have requirements about power indication Tighten all cable glands sufficient by means of a tool to ensure that the Ingres protection is IPX5 and to ensure that the cables are fixed in position and protected for physical traction and pressure N If not all cable outlets are used the cable gland s in question has to be changed to dummy plug s of the same dimension to ensure that the Ingres Protection still is IPX5 O This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or in struction concerning use of the appliance by a responsible for their safety P Children should be supervised to ensure that they do not play with the appliance md OWP TO sraer How to mount cable onto cable gland T END 1 Pull the cable through A 2 Pull the cable through B and C B is normally placed inside C 3 Tighten A sufficient onto C by means of a tool 4 Mount
9. ende tilsluttes klemraekken m rket A og hvis n dvendigt til JORD Bl ser eller lignende tilsluttes klemraekken m rket B og hvis n dvendigt til JORD Undervandslampe eller lignende tilsluttes klemr kken m rket C og hvis n dvendigt til JORD Kontrol boksen kobles til lysnettet via klemraekken m rket MAINS og til JORD UP amp D Jumper indstillinger Jumper Beskrivelse ON OFF Niveau torbl sning Aktivering er betinget af Kan betjenes uafh ngigt af vandniveauet X1 udgang B korrekt vandniveau Desuden er t rbl sningsprogram aktivt Aktivering er betinget af l X2 Niveau udgang C korrekt vandnivesl Kan betjenes uafh ngigt af vandniveauet X3 Timer C 30 min timer Ingen timer X4 Ingen funktion Funktionsbeskrivelse Karret fyldes s ledes at vandniveauet mindst d kker halvdelen af sensorens foleflade Dette tillader anl gsdrift Ved et tryk pa touchen startes massagepumpen eller anden tilsluttet enhed Dette indikeres via diode pa tou chen Kontrolboksen tillader 30 minutters drift ved jumper X3 i ON position Med jumper X3 i OFF position kan timeren frakobles Torbleesning X1 i OFF 20 minutter efter vandet falder under niveausensoren starter bl ser pa udgang B og k rer i 2 minutter for at bleese luftkanalerne rene Parring af fjernbetjening 25 2600 Ved f rste anvendelse af RF fjernbetjeningen tilbeh r skal enhederne parres Bem rk at sp ndingen
10. ng 230 V 50 60 Hz 1 fase M rkeeffekt 3680 W M rkestr m 16 A Udgangene A og B kan individuelt belastes med op til max 3680W 16A hver Dog ma den totale belastning ikke overstige m rke effekten og maerke strammen Dimensioner amp temperatur V gt 0 5 kg L ngde 180 mm Bredde 105 mm Dybde 75 mm Driftstemperatur 0 50 C Opbevaringstemperatur 20 60 C Vigtigt Kontrolboksen er ikke egnet til medicinsk brug F lg altid instruktionen under montering og tilslutning Vi forbehol der os ret til at ndre i produktet og manualen uden varsel Sikkerhedsregler Boksen anbringes p et t rt og godt ventileret sted Boksen skal anbringes mindst 3 cm over gulvet Str mtilf rslen skal altid afbrydes f r rensning reparation udskiftning af reserve dele eller tilbeh r og ved unders gelse af evt uregelm ssigheder Der m ikke forefindes utilsluttede kabler eller ledninger inde i boksen Kabler og ledninger skal v re s korte som muligt b de indeni og udenfor boksen System 500 er henh rende i sikkerhedsklasse I og m kun elektrisk forbindes i overensstemmelse med EN 60335 1 og EN 60335 2 60 Det anbefales at De r df rer Dem med en autoriseret elinstallat r Tilslut ningskablet skal som minimum v re type HO5VV F 3G1 5 mm Der skal v re en afstand pa mindst 20 mm mellem st rk og svagstramskabler Boksen skal adskilles fra nettet af en kontakt med en brydeafstand pa min 3 mm pa hver pol In
11. ns das Recht vor das Produkt und technische Details ohne Vorank ndigung zu andern Sicherheitsbestimmungen A Platzieren Sie das Ger t an einem trockenen und gut bel fteten Ort B Das Ger t muss mindestens 3 cm ber dem Boden aufgestellt werden C Vor der Reinigung Wartung dem Austausch von Teilen oder Zubeh r sowie der Behebung von St rungen muss die Stromzufuhr unterbrochen werden D Stellen Sie sicher dass sich keine unangeschlossenen Dr hte und Kabel innerhalb des Ger tes befinden E Kabel und Dr hte m ssen sowohl innerhalb als auch au erhalb des Ger tes so kurz wie m glich gehalten sein F Das Ger t entspricht der Sicherheitsstufe I Der Anschluss muss der EN 60335 1 und EN 60335 2 60 entsprechen und muss durch einen Fachmann ausgef hrt werden Das Stromkabel muss mindestens vom Typ HO5VV F 3G1 5 mm sein Zwischen der Hoch und Niederspannungsleitung ist ein Sicherheitsabstand von mindestens 20 mm einzuhalten Um im Fehlerfall das Ger t von der Stromzufuhr zu trennen ist ein entsprechender Fl Schalter zu installieren der mindestens 3 mm Abstand zu jedem Anschlusselement der bestehenden Elektroinstallation hat Die Montage muss so erfolgen dass es nicht m glich ist mit elektrischen Bauteilen in Ber hrung zu kommen Die Elektronischen Bauteile m ssen so montiert werden dass sie keinesfalls in die Wanne fallen k nnen Ger te der Klasse I m ssen an eine dauerhafte Installation angeschlossen werden Bi
12. pri avec une distance disruptive minimale de 3 mm sur chaque borne dans l installation lectrique actuelle Le montage doit tre effectu de mani re viter tout contact avec les composants lectriques Les composants lectriques doivent tre mont s de mani re ce qu ils ne puissent pas tomber dans la baignoire Les instruments de classe doivent tre connect s une installation permanente N oubliez pas que certains pays ont des exigences quant l indication de puissance Serrez suffisamment tous les presse toupes l aide d un outil afin de garantir un indice de protection IPX5 et assurez vous que tous les c bles sont fix s en position et prot g s contre la traction physique et la pression N Si toutes les sorties de c ble ne sont pas utilis es remplacez le ou les presse toupes en question par une ou des fiches factices de m me dimension afin de pr server l indice de protection IPX5 O Cet appareil n est pas destin tre utilis par des personnes y compris des enfants pr sentant des ca pacit s mentales physiques ou sensorielles r duites ou une exp rience et des connaissances insuffisan tes sauf si elles b n ficient d une supervision ou d instructions sur l utilisation de l appareil par un respon sable de leur s curit P Les enfants doivent tre surveill pour s assurer qu ils ne jouent pas avec l appareil nmo OWS TO a gt ZTA Montage du c ble sur le presse toupe
13. sser la puissance et l intensit nominales Dimensions amp temp rature Poids 0 5 kg Longueur 180 mm Largeur 105 mm Profondeur 75 mm Temp rature de fonctionnement 0 50 C Temp rature de stockage 20 50 C aa Important Ce bo tier lectronique ne convient pas un usage m dical Respectez les instructions d installation et de rac cordement Nous nous r servons le droit de modifier le produit et les sp cifications sans pr avis Consignes de s curit Installez le boitier dans un endroit sec et bien ventil Le bo tier doit tre situ au moins 3 cm au dessus du sol Coupez l alimentation secteur avant le nettoyage l entretien le remplacement de pi ces ou d accessoires ou le contr le en cas de perturbations diverses Assurez vous qu aucun c ble ni fil n est d branch dans le bo tier Les c bles et fils doivent tre aussi courts que possible tant l int rieur qu l ext rieur du bo tier Le bo tier pr sente un indice de protection I Il doit tre connect avec des fils conform ment aux instruc tions des normes EN 60335 1 et EN 60335 2 60 Il est recommand de contacter un lectricien agr Le c ble d alimentation doit tre au minimum de type HO5VV F 3G1 5 mm Maintenez toujours une distance minimale de 20 mm entre les c bles d alimentation haute et basse tension Pour s parer le bo tier du secteur vous devez installer un disjoncteur de fuite la terre appro
14. stalleringen skal foretages s ledes at det ikke er muligt for brugeren at ber re elfgrende dele Alle elektriske dele skal v re s ledes monteret at der ikke er mulighed for at disse kan falde ned i karret Apparater af Klasse skal veere forbundet til en fast installation V r opm rksom pa at nogle lande har krav om synlig sp ndingsindikation Sp nd alle kabel forskruninger tilstr kkeligt ved hj lp af v rkt j for at sikre IPX5 t thedsgraden samt for at aflaste kablet N Hvis ikke alle kabel forskruninger anvendes skal de udskiftes til bl nd propper for at sikre IPX5 t theds graden O Udstyret er ikke beregnet til brug for personer inkl b rn med fysiske eller mentale handikap eller personer uden erfaring eller viden i brugen Der b r gives instruktion i brugen af installationen af hensyn til deres sikkerhed P B rn b r overv ges for at sikre at de ikke leger med installationen nmo OWP SFA 2G Hvordan man samler kablet og forskrunin Tr k kablet igennem A 2 Tr k kablet igennem B amp C B er normalt placeret indeni C 3 Skrue A stramt ovenpa C tilstreekkeligt ved hj lp af v rkt j 4 Mont r spadesko og ring kabelsko pa kablet hvor det er n dvendigt 7 8 ELEKTRONISK KONTROL BOKS 3 FUNKTION 20 0243 Kabel og ledningstilslutninger Vandstandssensoren 25 0211 5 tilsluttes stikket m rket LEVEL 3 funktions touch tilsluttes klemreekke m rket TOUCH Pumpe eller lign
15. the spade and eye shoes onto wire ends where this is necessary 49 20 0243 www hydroair dk March 2009 1 8 ELECTRONIC CONTROL BOX 3 FUNCTIONS 20 0243 Cabling and wiring Water level sensor 25 0211 5 is connected to the connector marked LEVEL 3 function touch is connected to screw terminals marked TOUCH Pump or similar is connected to spade terminal marked A and if necessary to earth Blower or similar is connected to spade terminal marked B and if necessary to earth Underwater light or similar is connected to spade terminal marked C and if necessary to earth Control box is connected to MAINS via spade terminals marked MAINS and to earth ROR Goh Ni Jumper settings All Jumpers are default in ON possession Jumper Function ON OFF X1 Water level dry blowing Correct water level is Operation independent of water level output B required for activation Dry blowing program active X2 Water level output C Sed cast Operation independent of water level X3 Timer C 30 minutes timer No timer X4 No function N A N A Functional description The bathtub is filled with water until at least halve the sensor is covered This allows operation By pressing the touch the pump or any connected device will start This is indicated by LED on the touch With jumper X3 in ON position a 30 minutes timer is activated With jumper X3 in OFF position the timer is disabled Dry blowing program
16. tte beachten Sie dass einige L nder besondere Vorschriften f r den Anschluss an die Stromversorgung haben Ziehen Sie alle Kabelverschraubungen mithilfe von Werkzeug ausreichend fest um zu gew hrleisten dass der Eindringschutz IP IPX5 ist und dass die Kabel an ihrer Position befestigt und gegen physikalische Zugkr fte und Druck gesch tzt sind N Wenn nicht alle Kabelausg nge benutzt werden wird werden die entsprechende n Kabelverschraubung en gegen einen Blindstecker desselben Ausma es ausgetauscht um abzusichern dass der Eindringschutz IP auch weiterhin IPX5 ist O Das Ger t ist nicht f r die Bedienung durch Personen einschl Kinder mit eingeschr nkten physischen sensorischen oder geistigen F higkeiten oder fehlender Erfahrung und Kenntnis geeignet es sei denn sie stehen unter Aufsicht oder werden durch einen Verantwortlichen bez glich des Gebrauchs des Ger ts zu ihrer eigenen Sicherheit angewiesen P Kinder sollten beaufsichtigt werden um zu gew hrleisten dass sie nicht mit dem Ger t spielen TO ETAT Montage des Kabels an der Kabelverschraubun 4 A 1 Das Kabel durch A ziehen 2 Das Kabel durch B und C ziehen B ist normalerweise in C angebracht 3 Ziehen Sie A ausreichend an C mithilfe eines Werkzeugs fest 4 Montieren Sie wenn n tig die Anschlussklemmen an den Kabelenden ELEKTRONISCHE STEUERUNG 3 FUNKTIONEN 20 0243 Kabel und Leitungsfuhrung le Der Wasserstandssensor 20 02