Z-Wave.Me Wall Flush- Mountables Manual
Contents
1. Troubles that can be caused by other devices as is the case in open non regulated frequencies e g 433 MHz are excluded Established Although the Z Wave technology is new it has already developed to form a technical standard Renowned manufacturers from various fields offer solutions and applications that are based on Z Wave technology and compatible among one another This makes the system fit for the future and promises further upgrade phases Further information can be found on WWW Z wave com Dynamic Z Wave is equipped with a dynamic network structure Right from the start the position of the individual Z Wave device that is supplied with 230 Volts is monitored and automatically updated in the case of changes As a means of which it is possible to continuously adapt the network to its individual requirements wholly automatically without the necessity of any programming tasks 2 Before Installation Setup Please read carefully the enclosed user manual before installation of the radio actuator in order to ensure an error free functioning ATTENTION only authorized technicians under consideration of the country specific installation guidelines norms may do works with 230 Volt networks Prior to the assembly of the product the voltage network has to be switched off and ensured against re switching The product is permitted only for proper use as specified in the user manual Any kind of guarantee claim has to be forfeited i
2. Action on button single press or hold parameter No 13 size 1 byte Defines which command should be sent on button single press or hold Basic commands are sent to Association group Switch All commands are sent broadcast Values 0 Disabled 1 Switch On Off and dim using Basic Set default 2 Switch All On Off Action on button double press or hold parameter No 14 size 1 byte Defines which command should be sent on button double press or press hold Basic commands are sent to Association group Switch All commands are sent broadcast If not disabled the device will wait for a click timeout to see if the second click would be pressed This will introduce a small delay for single click commands Values 0 Disabled don t wait for double click default 1 Switch On Off and dim using Basic Set 2 Switch All On Off Send the following Switch All commands parameter No 15 size 1 byte Values 1 Switch All Off only default 2 Switch All On only 255 Switch All On and Off 5 5 Z Wave Specific Device Information 5 5 1 Z Wave Device Types Switch e Generic Binary Switch e Specific Binary Power Switch Dimmer e Generic Multilevel Switch e Specific Multilevel Power Switch Motor Control e Generic Multilevel Switch e Specific Motor Control Class C 5 5 2 Supported Command Classes All Switch V1 Association V2 Basic V1 Binary Switch V1 not for dimmer Configuration V1 Indicator V1 Manufact
3. g disk saw Operate only equipments that are approved for operating at 230 V 50 Hz Do not use radio controlled wireless switch dimmer sunblind in security areas e g as emergency switch or alarm Load the wireless switch dimmer sunblind only up to the specified maximum load
4. radio system can be combined The transmission or reception range is up to 100 m in free field and is dependent on the onsite prevailing conditions 9 Technical data 9 1 Wireless Switch Flush Mountable Receiving frequency 868 42 MHz Switching capacity 2 300 W 460 VA 600 W incandescent bulbs Operating voltage 230 V 50 Hz Micro fuse T 10 AH Dimensions H x W x D 52 x 52 x 31 mm without cover 71x 71x42 mm with cover Operating temperature 0 C to 40 C 9 2 Wireless Dimmer Flush Mountable Receiving frequency 868 42 MHz Switching capacity HV NV Halogen incandescent bulbs 25 300 W 40 300 VA Operating voltage 230 V 50 Hz Micro fuse T 1 25 A H Dimensions H x W x D 52 x 52 x 31 mm without cover 71x71x42 mm with cover Operating temperature 0 C to 40 C 9 3 Wireless Flush Mountable of sun blind Receiving frequency 868 42 MHz Switching capacity resistive 1 800 W 460 VA motors luminescent lamps 500 W incandescent bulbs Operating voltage 230 V 50 Hz Switching time 1 minute time period is factory set and can be changed Micro fuse T8 AH e Dimensions H x W x D 52 x 52 x 31 mm without cover 71x 71x42 mm with cover e Operating temperature 0 C to 40 C All the above mentioned products comply with the norms only in indoor use RTTE 1999 05 EG EN 60669 WRONG APPLICATIONS Do not operate any equipment that could cause damages while inadvertently turning on e
5. 55 in s default is 3 s Node Id of the blocking device parameter No 6 size 1 byte for motor control only Id of the blocking device Commands from this device would be interpreted not as Open Close but as block unblock Useful with door opening detector if the door is open block the blind not to break shades while they move Values 0 disabled default 1 232 Node Id of the blocking device Set Maximum Light on On click parameter No 7 size 1 byte for dimmer only Defines if the dimmer shall set maximum light level on On command By default on On command dimmer restores last level This parameter allows to configure to set maximum level on second On command if already On or to always switch on to maximum level Values 0 No default 1 if already in On state 2 Always On which command from blocking node to enable the protection parameter No 7 size 1 byte for motor control only Defines which command from blocking device to interpret as closed door and hence unprotected Values 0 on On default 1 on Off Baby Dimming Time parameter No 8 size 1 byte for dimmer only Time to dim on double click Off button for Baby Dim function This function works only if the load is operated by single press and hold button action If enabled the device will wait for a click timeout to see if the second click would be pressed This will introduce a small delay for single click commands unprotected Va
6. Z Wave Me Wall Flush Mountables Manual ZME_06431 Switch ZME_06433 Dimmer ZME_06436 Motor Control Firmware Version 1 5 1 General Information about Z Wave Safe Generally radio systems build a direct link between the transmitter and the receiver The radio signal is attenuated by every obstacle along its path in the household e g wall furniture etc In the worst case the radio system ceases to function The advantage of the intelligent Z Wave system is the so called routing function All devices of Z Wave not only act as transmitter or receiver but also simultaneously as repeater Should a direct radio link between the transmitter and the receiver not be possible communication will be established with the assistance of other devices Communicative Z Wave is a bidirectional radio system This means that a signal is not just sent but also a feedback confirming the reception of the signal occurs automatically The safety of transmission of the Z Wave radio bus technology is comparable with that of a wire linked bus system It is likewise possible to determine the switching status by pushing a button Has the cellar light been definitely switched off Trouble free Z Wave transmits at a regulated frequency band with a frequency of 868 MHz Every Z Wave network has its own unique network identification Therefore it is possible to operate two or more independently operating networks in a room or home without any interference
7. e network Only device that are part of the same network can send commands to the device 1 Follow the instructions on your Z Wave Primary or Inclusion Controller to include add a Z Wave device Press Up or Down button three times during 1 5 seconds The LED will become green for 3 seconds and then turn off Your device is ready to work ey 5 2 Z Wave Network Exclusion In order to remove the device from a Z Wave network the following steps have to be performed 1 Follow the instructions on your Z Wave Primary or Inclusion Controller to exclude remove a Z Wave device 2 Press Up or Down button three times during 1 5 seconds 3 The LED will begin to blink with red and green continuously 4 Note All configurations and associations stored in the device are deleted during Exclusion process 5 Your device can now be removed physically Attention Removing the device from the network means that it is turned back into factory default status 5 3 Z Wave Associations The Flush Mountable supports single and double paddle click to control other Z Wave devices The relationship between a controller paddle click and an action on a different Z Wave device is called association If there are different buttons or different ways to operate a button this may result in different actions Devices that receive the same command from such an action are referred to as association groups Refer to your Z Wave Controller instructions to add devic
8. es in these association groups A PC gateway controller gives you the most comfortable and powerful way to configure your device Association groups 1 Single click or hold control devices in Association group No 1 2 Double click or click hold control devices in group No 2 3 Devices in Association group No 3 are informed about all device switch state changes All groups support up to 8 nodes and 8 node channel pairs 5 4 Z Wave Configuration Z Wave products are supposed to work out of the box after inclusion however certain configuration can adapt the function better to user needs or unlock further enhanced features Note Configuration parameters 1 3 and 10 15 are similar for all three devices switches don t support configuration 5 9 dimmers don t support configurations 8 9 IMPORTANT Controllers may only allow to configure signed values In order to set values in the range 128 255 for parameters 4 5 and 6 the value sent in the application shall be the desired value minus 256 For example to set parameter 4 in Window Blind to 200 s it may be needed to set a value of 200 256 56 Similar rule applies to parameter 2 to set values in range 32768 65535 use value equal to desired value minus 65536 For example to set auto switch off period to 10 hours 36000 s it may be needed to set a value 36000 65536 29536 LED mode parameter No 1 size 1 byte Set LED indication mode Values 0 Disabled 1 Sho
9. f changes modifications or painting are undertaken The product must be checked for damages immediately after unpacking In the case of damages the product must not be operated in any case If a danger free operation of the equipment cannot be assured the voltage supply has to be immediately interrupted and the equipment has to be protected from unintended operation 3 Product Description Switch This device is designed to switch any kind of 230 V mains connected electrical load resistive inductive and reactive The maximum electrical load is defined in the technical product spec Dimmer This device is designed to dim attached lights Usage is restricted to incandescent light high voltage Halogen lamps and any low voltage and Compact Fluorescent Lights CFL with resistive or inductive load The dimmer can t dim any reactive load typically for certain switching power supplies or CFLs Please make sure the right load is connected to the dimmer before operating Connecting a reactive load may destroy both the load and the dimmer The maximum electrical load is defined in the technical product spec Sun blind Control The device is designed to control single or double motor sunblind shutters or electrical gates The controller turns on a 230 V supply or any other voltage supply to operate the motor and turns off the supply automatically after 1 minute in order to protect the motor It is possible to adjust the operation time T
10. f the device is not possible The child protection mode MUST be turned on wirelessly However it is possible to unlock the device for local operation with a triple click The unlock state will last for 5 seconds 7 Electrical leads 7 1 Switch in 3 way mode Switching off l N 1 2 lead in AC 230V 50 Hz neutral line z5 I switched line 7 2 Dimmer in 2 Way mode IE og L lead in y AC 230 V 50 Hz neutral line switched line BZ 7 3 Sun blind control Motor Control 230 V Mains powered Motor Control other voltages Motor Voltage 8 Micro Fuse Dimmer Flush Mountable Type T 1 25 A H Load 1 25 Ampere high shutdown capacity D 5 mm L 20 mm Switch Flush Mountable Type T 10 AH Load 10 Ampere high shutdown capacity D 5 mm L 20 mm Sun blind Flush Mountable Type T 8 AH Load 8 Ampere high shutdown capacity D 5mm L 20 mm NOTE The micro fuse deals with a backup for the equipment that is specifically designed to this radio controlled wireless dimmer switch sunblind Please use only this fuse type This micro fuse should protect this radio controlled wireless dimmer switch sunblind from overload and short circuits When using another fuse component there is a danger that the device can be destroyed A spare fuse is provided in the fuse holder TROUBLE NOTES All devices of the system have to be included therefore all the articles of the Z Wave
11. he maximum electrical load is defined in the technical product spec Note The use of Flush Mountables with equipment that does not comply with the technical standards can cause malfunctioning or damage connected equipments or flush mounted products 4 Installation The build in can be controlled both by using clipped on rockers as well as wireless wall switch or remote control The assembly must take place in a voltage free state by an authorized electrical technician Turn off the power supply prior to the mounting and confirm the absence of voltage with a 2 pin voltage checker Protect your installation from re switching An assembly in built in sockets is possible As a result of the compact design the wireless switch dimmer sunblind control can be fastened to canopies depth min 30 mm into sunblinds and suspended ceilings etc For facilitating this purpose the clipped on switch or base plate may be removed With the help of a flush mounted product an existing switch installation can be enhanced to a wireless capable one The wireless Flush Mountable including support ring and the radio rocker replaces the existing switch It can also be manually switched as before however it can also be alternatively remote controlled by means of a controller remote control or wall switch 5 Wireless Functions Z Wave 5 1 Z Wave Network Inclusion In order to use the device by a controller the device needs to be included into a Z Wav
12. lues 0 off default 1 255 minutes Reaction on opposite Button parameter No 8 size 1 byte for motor control only Defines how the device shall react when hitting the opposite direction button when motor is moving Values 0 Stop default 1 Stop and start moving reverse direction Target Dimming Level for Baby Dimming parameter No 9 size 1 byte for dimmer only Target level on which to stop while executing Baby Dimming Can be 0 to completely switch off the light Values 0 99 dimmer level default is 0 Invert Open and Close relays parameter No 9 size 1 byte for motor control only Allow exchanging open and close relays if blind control is wired to the motor incorrectly Values 0 No default 1 Yes Typical click timeout parameter No 10 size 1 byte Typical time used to differentiate click hold double and triple clicks Values 1 100 in 10 ms units default is 50 that is equivalent to 500 ms Invert buttons parameter No 11 size 1 byte Values 0 No default 1 Yes Switch by buttons parameter No 12 size 1 byte If disabled the local operations by buttons will not switch the load but only send commands to On Off association group In this mode buttons are not linked with the switch anymore They can be used separately buttons to control remote device switch will operate by RF commands only Values 0 No 1 By single press and hold default 2 By double press and press hold
13. o 4 size 1 byte for motor control only Time to go from opened to closed state Used to estimate the current level Note that in permanent motion mode the reported value would be closed or opened while all Basic and Multilevel Set values 1 99 255 would open except 0 value that would close Values 0 keep in permanent motion 1 255 in s default is 60 s Restore Switch State after Power Cycle parameter No 5 size 1 byte for switch only Defines if the switch should restore switch state to the last state prior to device power off power cycle Values 0 No 1 Yes default Dimmer speed parameter No 5 size 1 byte for dimmer only Time to dim on button presses and Set command if it has no duration specified If not 0 dimming will be done smoothly to preserve bulb life Values 0 instantly 1 255 in 10 ms units default is 30 equal to 300 ms Full open time parameter No 5 size 1 byte for motor control only Time to go from closed to opened state Used to estimate the current level Note that in permanent motion mode the reported value would be closed or opened while all Basic and Multilevel Set values 1 99 255 would open except 0 value that would close Values 0 keep in permanent motion 1 255 in s default is 60 s Dimming Long speed parameter No 6 size 1 byte for dimmer only Time to dim on button holds and StartLevelChange command if it has no duration specified Values 1 2
14. urer Specific V1 Multi Channel Association V2 Multilevel Switch V3 for blind V2 for dimmer not for switch Node Naming and Location V1 Protection V1 Version V1 5 5 3 Controlled Command Classes Switch All Multi Channel Basic Multilevel Switch 6 Use Handling and LED indicator Switch Switched on off by a short press Dimmer Short press switches the light on or off Long pressing the rocker starts dimming the light up or down Releasing the rocker stops the dimming The dimmer saves the last dimming state In case the dimmer switches off short press and switches on again short press the last dimming state is used Sun blind Moves to upper and lower end points by short pressing the buttons A short press in the opposite direction can stop the movement Long press or holding down the button directs the blind in the desired direction but movement will stop when the rocker is released LED indicator e Red and green blinking continuously Device is not included in a Z Wave network e Red lights up for 3 seconds Device was not included excluded after being put into learn mode by triple press of up down button e Green lights up for 3 seconds The inclusion exclusion was successful or new association was saved successfully e Green or no light depending on settings of configuration parameter 1 Child Protection The device can be turn into a child protection mode This means that the local operation o
15. w switch dimmer state when in motion or inactive for blinds 2 Night mode inverted switch state 3 Operated by Indicator Command Class default 4 Show if not closed for blinds only Automatically switch off after parameter No 2 size 2 bytes If not zero automatically switch off close blind after a user defined time Values 0 Disabled default 1 65535 Switch off close blind after this time in s What to do on RF off command parameter No 3 size 1 byte Defines how to interpret RF Off command Can be used in conjunction with Auto Off function Ignore to switch on the light by motion detectors and switch it off after some amount of time in case of multiple motion detectors each would try to switch the light off that would break logics Switch on to switch on the light on both On and Off paddle press on the remote and switch it off after some amount of time Button off click will still work if button operations are not disabled Values 0 Switch off default 1 Ignore 2 Switch on Switch on dimming by buttons parameter No 4 size 1 byte for switch only Defines if the switch should change it state to on off if it is dimmed by buttons Values 0 No 1 Yes default Ignore Start Level parameter No 4 size 1 byte for dimmer only Defines if the dimmer shall ignore start level in StartLevelChange command despite it is specified or not Values 0 No 1 Yes default Full close time parameter N