Home

TEST EQUIPMENT/EQUIPO DE PRUEBA

image

Contents

1. measurements and Gas Flow JMB BIOMED INTERNATIONAL INC TEL 305 597 0898 FAX 305 718 8819 w YJINYd Id OdINOI INIWdINOF LSIL NTERNATIONAL CATALOGO 2004 QA IDS INFUSION PUMP TESTER QA IDS Infusion Pump Tester completes tests according to national and international standards This includes taking flow measurements every 30 seconds so that the measurements are independent of the infusion pump s flow rate QA IDS is capable of detecting volume variations of 0 72 ulina range of 0 10 ml h 1000 0 ml h QA IDS can test all types of infusion pumps It carries out flow tests bolus tests and occlusion alarm tests Features Very high accuracy and resolution High sampling rate sudden flow change minimum volume detection 0 7ul Generates a user defined pressure to load the infusion pump during test 200mmHg to 600mmHg AGU 2 CANNEL INFUSION PUMP TESTER _ lagu Infusion Pump Tester completes tests according to IEC 601 2 24 standard This includes taking flow measurements every 30 seconds so that the measurements are independent of the infusion pump s flow rate lagu is capable of detecting volume variations of 0 18 ul in a range of 0 10 ml h 1000 0 ml h lagu is a true dual channel infusion pump tester Each channel is operated independently using its own measuring system lagu can test all types of infusion pumps It carries out flow tests bolus tests and occlusion alarm tests PRO Soft lagu software lets you to remotel
2. taken in uW cm2 with a range of 0 1999 This unit of measurement can be directly compared to other units of measurement as described in the user s manual Features Large LCD Accuracy to 5 of full scale Spectral range of 429 473 nm and Complete portability PM TEST CART Bio Tek s PM Test Cart is specially designed and tested to meet the exacting F gt requirements of biomedical and maintenance personnel Its all plastic construction prevents electrical problems usually associated with metal carts The cart provides space for all equipment and has drawers deep enough to store equipment A keyboard tray is included for use with laptop computers The wheels are precision crafted to offer smooth non marring gliding over all possible flooring types encountered in today s healthcare setting JMB BIOMED INTERNATIONAL INC Www jmbbi com w WGINId 10 OdINOI INIWdINOI LSI TST8 08 04 TEST EQUIPMENT EQUIPO DE PRUEBA CATALOGO 2004 DPM 1B 1 accuracy troubleshooting The Model DPM 1 is a hand held pressure gen erating device designed for calibration and troubleshooting pneumatic or hydraulic systems An LCD indicates pressure received externally or pressures manually generated from the internal chamber To test BP transducers or monitors simply connect a BP transducer to the luer lock fitting on the DPM 1B and create any series of pressures from 300 to 300 mmHg by turning the thumb wheel Includes fitt
3. use Auto calibration against all NIBP units Real blood pressure waveforms settings Real life artifact and arrhythmia Actual BP waveforms based on clinical data Performs a complete test including cuff and tubing QA ES ELECTROSURGICAL ANALYZER The QA ES is developed for simple execution of tests on high frequency surgical equipment in accordance with national and international standards including IEC 601 2 2 EN 60601 2 2 and ANSI AAMI HF 18 QA ES is unique in that it can automatically execute a power distribution test with a load resistance ranging from 10 ohm to a maximum of 5200 ohms The automatic measuring of the QA ES including crest factor measurements with a bandwidth of 10 MHz ensure that the test result is reliable and reproducible The test result can either be printed directly from the analyzer or transferred to a PC via PRO Soft QA ES remote control software QA PT PARAMETER TESTER A Using the newest technology QA PT provides both high accuracy and performance for calibration or test of medical and industrial devices It is a versatile test instrument able to measure multiple parameters Basic parameters cover differential pressure vacuum and temperature measurements Gas flow barometric pressure and humidity measurements are included in the enhanced QA PT model 2 Features compact design Reliable measurements high accuracy Pressure and Vacuum measurements with peak hold Barometric Pressure measurements Temperature
4. contrast The unit runs on a 9V battery It provides an indication when battery is low and shuts down It also supplies RS232 two way data communication that is used to control the selections of the unit The RS232 can also provide information regarding the status of the PS 320 PS 410 PATIENT SIMULATOR This Metron patient simulators has incorporated all the features and even greater quality and accuracy than that found in larger bulkier units The PS 410 features Compact Lightweight Pocket Size Easy top panel control 12 Lead ECG Adult and Pediatric Normal Sinus Rhythms 35 Arrhythmias ECG Performance Waveforms ST Segment Levels ECG Artifact Pacemaker Simulation JMB BIOMED INTERNATIONAL INC TEL 305 597 0898 FAX 305 718 8819 vo YdINUd 70 OdINOI INIWdINOF L571 TEST EQUIPMENT EQUIPO DE PRUEBA TST4 08 04 CATALOGO 2004 PS 420 PATIENT SIMULATOR Metron s PS 420 patient simulator is the smallest most power packed cost effective patient simulator on the market The PA 420 features Compact Lightweight Pocket Size design Labeled Hot Keys for Common Settings Simulates 12 Lead ECG Respiration Temperature 2 Channel Blood Pressure Simulations Cardiac Output optional Adult and Pediatric Normal Sinus Rhythms 37 Arrhythmias ECG Performance Waveforms ST Segment Levels ECG Artifact Pacemaker Simulation Includes RS 232 Interface PS 440 PATIENT SIMULATOR Metron s PS 440 patient simulator is the smalles
5. ewbioMe NTERNATIONAL CATALOGO 2004 QA 90MKII The QA 90 represents a new generation of safety testing equipment QA 90 is the only automatic safety tester that can test Instruments containing modules with different classes of protection in one test run i e CF and BF defibrillators It is simple to use All you need do is select the type and class of the equipment to be tested When you press START the QA 90 will execute the tests prescribed in the selected standard The test result can either be printed out immediately or stored internally in the unit for later use The QA 90 can be fully remotely controlled via ansur QA 90 software With ansur you can make your own test protocols store the information on disk and export formatted data to equipment management QA 7290 NIBP ANALYZER By using innovative new technology the QA 1290 NIBP Simulator accurately tests all types of adult and neonate oscillometric NIBP monitors Before simulation the QA 1290 can calibrate both the cuff and tubing in order to verify the NIBP monitor Once the QA 1290 knows the working environment it is able to perform calibrated simulations under all conditions The QA 1290 provides dynamic performance testing using both real and simulated blood pressure waveforms Blood pressure waveforms include individual settings for systolic BP diastolic BP heart rate and the pulse volume amplitude The QA 1290 Features High performance compact design simple to
6. ic printer interface QA 40M DEFIBRILLATOR ANALYZER The QA 40M is a defibrillator analyzer developed for testing all external defibrillators The unit may operate as a powerful standalone device or may be incorporated into an automated PC based and remotely controlled The test results can either be written directly to a printer from the QA 40M or they may be transferred to ansur QA 40M 45 test automation software The QA 40M features Biphasic energy measurement Energy and cardioversion measurement Peak voltage and current reading Storage and playback of output waveform 12 lead ECG simulation ECG Performance and Arrhythmia simulation Automatic defibrillator test procedures Large graphic display RS 232C and Centronic printer interface PS 320 FETAL SIMULATOR Cardiotocographs or Electronic Fetal Monitoring EFM is a diagnostic tool used to _ identify a fetus at risk for neurological injury or death so that timely and appropriate intervention can be carried out before the underlying condition causes irreversible damage The PS 320 provides comprehensive simulation of fetal and maternal ECG as well as uterine activity It can simulate several fetal parameters including twins via monitor modes as DECG and ultrasound With the optional Mechanical Heart you can test any fetal monitor s ultrasound cable and transducer using heart sounds PS 320 offers an easy user interface providing a 2 x 16 character LCD display with adjustable
7. ing voltage from 100 115 or 240 V 50 60Hz Power configuration test Supply Voltage measurements Current Consumption Ground wire resistance Ground chassis and patient leakage current Lead Isolation test Lead to Lead leakage current Direct leakage current Test loads AAMI ANSI ES1 1985 or IEC 60601 1 RS 232 Standard feature Automation with ansur test integration software JMB BIOMED INTERNATIONAL INC TEL 309 597 0898 FAX 305 718 8819 w WGINd 70 OdINOI INIWdINOI L571 CATALOGO 2004 RespiCal For more than a decade health care professionals have depended on the RT Timeter 200 for day in day out performance Today the workhorse RT 200 has a wor thy successor the RespiCal by Allied Healthcare It offers so many new byAllied applications it represents more of a revolution than an evolution Consider how the new and enhanced capabilities of the RespiCal can help you deliver better care more effectively and productively than ever before possible Stand alone operation or use with a Windows 95 personal computer Both numeric and graphic displays of any two real time measure ments simultaneously High pressure low pressure high flow low flow oxygen percentage or 0 to 10V external input All information can be documented and stored electronically for monitoring and record keeping In stand alone mode RespiCal can measure pressures flows volumes barometric pressure oxygen concentra
8. ings manual and 1 year warranty DPMI II The DPM 2 Plus Universal Pressure Meter measures positive or negative pressures Operators use a single mode switch to select one of four measurement parameters An LCD readout displays pressures received externally from pneumatic or hydraulic sources Applications include Opthalmological lasers Dialysis machines Automatic tourniquets Drainage devices IV pumps Diagnostic and surgical suction devices Ventilators Pressure gauges and many others Includes fittings manual and 1 year DPM III Convenient compact pressure and temperature tester The Universal Biometer is a versatile test instrument able to measure pneumatic or hydraulic pressures both positive or negative in a variety of ranges We ve added the ability to measure temperature in degrees Centigrade or p gt 4s Fahrenheit with standard YSI 700 Series probes Includes fittings temperature probe manual and 1 year warranty PARABOLIC FLOW ADAPTER The Bio Tek Parabolic Flow Adapter Model PFA 1 is a unique hand held easy to use device enabling users of Bio Tek Universal Pressure Meters to make critical gas flow measurements in hospitals factories or service centers Typical applications include calibrating flows of various gases from wall outlets breathing machines ventilators anesthesia machines compressors and regulators The operation of the Model PFA is based on the principle that the differential
9. l external cardiac pacemakers including invasive and non invasive transthoracic types Its comprehensive range of tests and simulations will meet the needs of all cardiac units k Features Hand held portability All necessary test leads Large 2 line LCD i Comprehensive test ranges Replaces 5 separate test devices Includes cables manual and 1 year warranty 1726 DIGITAL TACOMETER The Model 1726 Hand Held Digital Tachometer is a dual function instrument providing contact and non contact measurement of rotational and linear motions With an accuracy of 035 of indicated reading the 1726 is ideal for use in pro duction engineering inspection quality control and maintenance The Model 1726 comes complete with a convex tip and 10 cm linear measuring wheel Contact or non contact measurement Eight character display with floating decimal point Four memories last minimum maximum and average readings Units of measure available Revolutions sec min hr Inches sec min hr Feet sec min hr Yards sec min hr Miles hr Centimeters sec and Meters min hr Includes heads carry case units chart manual and 1 year X74345 Instant measurement of light output The Bio Tek Phototherapy Radiometer Model 74345 is designed to accurately measure light radiation in the blue part of the spectrum from 429 473 nanometers Phototherapy exposure in this range is used to treat hyperbilirubinemia in newborn children Measurements are
10. pressure measured across a known restrictor is proportional to the flow of gas through the restrictor RF303 Electrosurgery device testing has never been this simple The wide selection Biomed shop with multiple ESU makes and models Accurately test the following ESU functions output power high frequency HF leakage and CQM contact quality monitor The battery operation provides the portability needed to test ESUs in the OR or doctor s offices Features Battery powered for completely isolated measurement 15 user selectable test loads 50 750 in 50 steps Digital display HF Leakage current measurement Oscilloscope output Safety test leads 4 digit numeric LCD with backlight and power save mode Includes cables adpater cables test leads manual and 1 year warranty JMB BIOMED INTERNATIONAL INC TEL 309 997 0898 FAX 305 718 8819
11. s preventative maintenance procedures performance tests and safety tests for any device can be performed and stored from one file The test procedures are stored in Test Template or Test Sequence files XML format and the results are stored in Test Result files also in XML format which may be viewed and printed with three different detail levels JMB BIOMED INTERNATIONAL INC Wwww jmbbi com NTERNATIONAL CATALOGO 2004 QA VTM VENTILATOR TESTER QA VTM offers many unique features for verifying the performance of infant pediatric and adult mechanical ventilators breathing machines Unlike any other tester QA VTM makes it easy to add a test load lung simulation to the test system without corrupting the results Ventilation parameters including breath rate inspiratory and expiratory timing E ratio flow rates tidal volume and airway pressure can be checked Flow pressure and volume measurements can also be independently made For the purposes of troubleshooting or verifying operation a Trend Test can be selected and performed This test allows you to run a ventilator for up to 48 hours on the QA VTM and record key ventilation measurements For greater automation and enhanced viewing of the test data you may want to utilize the PRO Soft QA VTM test software With PRO Soft you can remotely control the unit create and save unique test sequences for each brand or model of ventilator perform automated tests and print the re
12. sults and or store them to disk PRO Soft also allows viewing of pressure volume and flow waveforms which can be useful in diagnosing problems or validating a ventilator s own on screen display Unique Doppler Measuring Technology Patent Pending Independent of gas agents used for testing O2 Air N2O or mixtures Tests High Frequency Ventilators Breath Rates from 0 to 600 BPM 10 Hz Tests with or without optional test loads simulated lungs Simultaneous display of multiple parameter e g rate volume flow PEEP Test infant pediatric and adult ventilators Trend testing up to 48 hours with PRO Soft High accuracy and resolution Simple to operate Centronics printer interface RS 232 computer interface User defined test protocols using PRO Soft QA VTM Pressure flow and volume wave forms using PRO Soft QA VTM QA ST ELECTRICAL SAFETY ANALYZER The QA ST is designed to quickly check electrical safety on medical and industrial devices It is palm sized and very portable The tests can be performed manually or in step by step mode The results are displayed in a bright 4 digit LCD display The QA ST performs all electrical safety tests necessary to satisfy AAMI ESI NFPA 99 VDE 751 and partially IEC60601 1 It also features residual current measurements obtained by an internal current clamp This presents a new leakage current measurement technique for convenient testing of medical equipment The QA ST features Operat
13. t most power packed patient simulator on the market The PA 440 features Compact Lightweight Pocket Size design Labeled Hot Keys for Common Settings Simulates 12 Lead ECG Respiration Temperature 4 Channel Blood Pressure Simulations Cardiac Output optional Adult and Pediatric Normal Sinus Rhythms 37 Arrhythmias ECG Performance Waveforms ST Segment Levels ECG Artifact Pacemaker Simulation Includes RS 232 Interface QA 30 PACEMAKER ANALYZER QA 30 is an advanced microprocessor based compact high performance external pacemaker tester designed for accurate testing of all types of external pacemakers including invasive and transthoracic The device is menu driven and simple to operate All functions are set from a 2 line 16 character LCD display and a keypad with 8 tactile keys QA 30 provides superior accuracy and performance Li D ae proceeding cebeci ha denial Ge miena aki comply aral he terece E reni is hsh bes caraj pal r THI im CO Pretrepas Funchon Check DO Did Geer Seeds ack ansur Test Automation Software is the evolution of Metron s PRO Soft software family It is the backbone for Metron s current and future automated test systems ansur is a test executive that handles all steps of your test procedures by allowing a mixture of manual visual tests and automated test sequences The software is designed to work hand in hand with Metron analyzers and simulators as an application where visual inspection
14. te your own test protocols store test results to disk and recall tests and results for future use TEST EQUIPMENT EQUIPO DE PRUEBA DAEG features Compact design Graphical display with backlighting 5 lead simulations of ECG Probe test With adaptor box Simple interactive procedure for generation of new R curves and templates Large flash memory for storage of hundreds of downloaded R curves JMB BIOMED INTERNATIONAL INC WWww jmbbi com TST2 08 04 NTERNATIONAL CATALOGO 2004 QA 45 DEFIBRILLATOR PACER ANALYZER The QA 40M is a defibrillator analyzer developed for testing all external defibrillators The unit may operate as a powerful standalone device or may be incorporated into an automated PC based and remotely controlled The test results can either be written directly to a printer from the QA 45 or they may be transferred to ansur QA 45 test automation software The QA 45 features Biphasic energy measurement Energy and cardioversion measurement Peak voltage and current reading Storage and playback of output waveform 12 lead ECG simulation ECG Performance and Arrhythmia simulation Automatic defibrillator test procedures Pacemaker loads from 50 ohm to 2300 ohm Accuracy Tests Amplitude Rate Pulse width Demand Sensitivity Tests Amplitude Rate Pulse width Square Triangle Haversine Sensed Refractory Period Paced Refractory Period60 50 Hz Immunity Test Pulse Energy Large graphic display RS 232C and Centron
15. tion breath calculations and voltages from many devices Plus the operator uses only four keys to control the unit S e International 4E amp 4EC RADIATION MONITORS The 4E y 4EC monitors provide a cost effective alternative for monitoring ionizing radiation Model 4E is ideal for the measurements of alpha beta pP gamma and x ray radiation The 4EC provides precise measument of high a Ey energy radiation above 40 keV Both instruments are accurate to within 10 s meee of reading referenced to Cesium 137 Both models feature an analog meter f calibrated in mR hr Carrying case and batteries are included Both units operate aproximately 2000hours 9V battery DIGILERT Digilert is a monitoring system with a built in alarm to alert personnel is the radiation levels in an area exceed a programmed number of counts per minute or a cumulative dose The user can specify the alarm level form 0 9990 counts per minute Digilert can be used to monitor alpha beta gamma and x ray radiation Carrying case and batteries are included The unit operates aproximately 2000hours 9V battery Two interface outputs are provided for connection to other alarm systems compatible with c TTL and CMOS TEST EQUIPMENT EQUIPO DE PRUEBA JMB BIOMED INTERNATIONAL INC Www jmbbi com TST6 08 04 NTERNATIONAL CATALOGO 2004 PMA1 Testing for an entire range of external pacemakers The PMA I has been specifically designed for use with al
16. y control the tester from a PC It allows you to create automated test sequences run the tests print the results and or store them to disk With PRO Soft lagu you may automatically test infusion pumps over long periods and against various loads SPO2 PROBE ANALYZER The SpO2 Probe Analyzer provides simple accurate tests for all types of SpO2 probes The analyzer tests photodiode response to red and infrared LEDs and performs a continuity test of circuits Red infrared and photodiode circuits are each tested For both tests there are two test types one short test 1 sec and one long glitch test 30 sec The long test can be aborted at any time Test results are displayed via a 7 segment display with 10 different messages There is also a RS 232 connection to PC and connectors to the probe For other types than Ohmeda and Nellcor probes adapters are used DAEG SPO2 ANALYZER The daeg SpO2 Analyzer provides simple and accurate testing of your Pulse Oximeters The Analyzer does not only perform SpO2 tests it also provides an electrical probe test and measures the quality of the IR and red LEDs The SpO2 Analyzer simulates a variety of patient conditions to test most modern oximeters New models of oximeters can easily be added to the unit s menu The finger probe concept gives excellent performance at a low cost Probes are calibrated as standalone units and therefore moveable between host units With PRO Soft software you can easily crea