Home

Manual - Instrumart

image

Contents

1. Page 17 MadgeTech OctTemp2000 Change Device ID Each OctTemp2000 can be given a device ID allowing for easy identification among multiple devices Device IDs are displayed on the Home Screen of the LCD and are used throughout the software and data files Page 18 Start Device screen 2 In the Device ID entry field type the desired Device ID name To change Device ID in the software 1 In the Device drop down menu select Start Device to view the 3 Select other desired start functions 4 m Stop Method m Start Parameters Device Type OctT emp Serial Number E62201 30 Seconds DI ff Start Device m Start Method Ze Start Now C Delay Start Manual Start Manual Timed C Readings Manual K Manual GE Device ID Extended ID Reading Rate T Wrap Around m Log Time Pav 242 als UE 7 KI reer 24 E EE EE 30 Days Hours Minutes Seconds m Battery Status Charge level WARNING Refer to the datasheet product manual or quick start quide for proper usage and handling or call the phone number below Specific warranty and remedy limitations apply to this product Call 603 456 2011 for details Click Start to start the device and save Device ID information Set Password Enabled Channels Channel Names Thermocouple Type Device type and user defined Device ID are displayed on the Home Screen Data Logger M
2. Computer Interface PC serial or USB interface cable required 115 200 baud Software XP SP Vista Windows 7 Operating Environment 20 to 60 C 0 to 95 RH non condensing Dimensions ll E Weight 150z Enclosure Black anodized aluminum Page 6 Data Logger Manual O Device Functions Channel Options T J T Each of the OctTemp2000 s channels ENaeLen D GE E have several options that are configurable 1 TELE SE by the user through the devices display screen menus and the software Show or Hide Channels on the Home Screen The user may choose to either show or hide channels on the home screen CHi OVER TC 1 Tupe J TC Erected HE MIA HES Man To change channel visibility from the Home Screen 1 Press to view first channel screen 2 Use to view additional channels 3 On desired channel screen use to highlight Visible 4 Use to choose Show or Hide 5 Press to return to the Home Screen OR 1 Use to highlight desired channel 2 Press to view channel screen 3 Use to highlight Visible 4 Use to choose Show or Hide 5 Press to return to the Home Screen Page 7 MadgeTech OctTemp2000 RE Page 8 Change Channel Display Size Channels may be viewed in a number of different sizes The smallest size allows for an overview of several channels at once while the largest gives at a glance access to one or two channels Pee WAS le
3. Note Information is only generated while the data logger is running and the reset does not affect statistics on download View Channel Statistics Minimum maximum and average values are calculated for each channel and displayed in the statistics screens Zb O haren D m AS H 1 26 E H S To view channel statistics from the Home Screen 1 Use to view desired statistic screen 2 In statistics screen use to view statistics for each channel 3 Use to scroll back to the Home Screen Clear Channel Statistics Statistics may be cleared and reset at any time l To CLEAR THE 2TATIZTICS la To clear channel statistics from the Home Screen 1 Press to enter the Main Menu 2 Use to highlight Clear Statistics 3 Press to select Clear Statistics 4 Press to confirm statistics clear to cancel Page 10 Data Logger Manual Time and Date Information Current time and date information is available on the LCD System time is automatically synchronized with your computer z clock To view time and date information from the Home Screen 1 Press to enter the Main Menu 2 Use to highlight Clock 3 Press to select Clock and view time and date information Manual Push button Start Devices set to start in Manual Push button mode can be started through the device s display screens at the user s convenience To manually start device from the Home Screen 1 Press to enter the Main Menu 2 Use t
4. construed as a waiver of these Terms and Conditions or as an acceptance of any such provision Trade custom trade usage and past performance are superseded by these terms and conditions and shall not be used to interpret these terms and conditions In the event that Product includes software the software is licensed to Buyer in object code form only in accordance with Seller s standard Software License Terms that are included below 20 Limited Warranty A Seller Manufactured Products and Seller Provided Services Seller warrants to Buyer that i Seller manufactured Software as defined in Section 23 below shall execute the programming instructions provided by Seller and ii Seller manufactured Product and consumables and Seller provided services shall be free from material defects in material and workmanship under normal uses and care in each case until the expiration of the applicable warranty period specified below Seller manufactured Product is warranted for the shorter of twelve 12 months from the date of initial installation or fifteen 15 months from the date of shipment by Seller Seller manufactured consumables and Software and Seller provided services are warranted for a period of ninety 90 days from the date of shipment or completion as applicable If Buyer discovers any warranty defect and notifies Seller thereof in writing during the applicable warranty period Seller shall at its option promptly correct any def
5. OctTemp2000 Eiz nn Hpac THERNGCnUEL E TEMIPERATUEC RCC CEP Gee eee EAS a A MAQGeTECH Data Logger Manual AA MADGETECH WE BUILD DATA LOGGERS Table of Contents OVET IOW eeo 2 Other Documentation EE 2 CO ACEI KE 2 Introducing the Oct emp 2000 3 Ree 3 Display eet 4 SC CIC e CN 5 Device Functions ccc cece ccc cececccccceccececcccececcececcscecencecencececenceuences 7 Channel ODUONS ates EE 7 Show or Hide Channels on the Main Screen 7 Change Channel Display Ee see eee eee eee 8 Change Channel Wits siseses anin 9 ELE E 10 View Channel Statistics cccccececsccececcececcccececcecencececenceecs 10 Clear Channel Statistics e 10 Time and Date Information 11 P sn button SAU EE 11 BITTEN 12 Device Status E EEN 12 Device Setup A E 13 Software Features eee 15 Enable and Disable Channels 15 Name Cane 17 Change Device ID eege 18 Battery MONI e nissens aoii Aa EE 19 Computer Interface ssessessesesescesecsssesssesssesesosesesssesesesssesssesessses 20 NEE 21 Terms and Conditions ccc ccceccececcccececcececcecececcecececscenceceucecs 22 Revised 09 15 09 Page 1 MadgeTech OctTemp2000 W Overview Other Documentation Other documents which may be of interest to you are the Software Operating Manual and Data Logger Quick Start Guide To obtain the most current versions of both of these documents please visit our website www madgetech com Contacting Us For addition
6. R FOR BREACH OF WARRANTY AND IS IN LIEU OF ALL OTHER REPRESENTATIONS Page 22 Data Logger Manual WARRANTIES AND COVENANTS EXPRESSED OR IMPLIED IN REGARD THERETO EXCEPT FOR THE EXPRESS LIMITED WARRANTY SET FORTH IN THIS SECTION SELLER DOES NOT MAKE AND HEREBY DISCLAIMS ANY AND ALL OTHER REPRESENTATIONS AND WARRANTIES OF ANY KIND WHATSOEVER WHETHER EXPRESSED IMPLIED OR STATUTORY INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE NONINFRINGEMENT OR ACCURACY ADEQUACY OR COMPLETENESS OF DATA MEASUREMENT WITH RESPECT TO ANY OF THE SELLER MANUFACTURED PRODUCTS CONSUMABLES OR SOFTWARE OR ANY OF THE SELLER PROVIDED SERVICES Any drawings submitted with the Products are only to show the general style arrangement and approximate dimensions of the Products B Equipment Consumables Software and Services Manufactured or Provided by Others SELLER DOES NOT MAKE AND HEREBY DISCLAIMS ANY AND ALL REPRESENTATIONS AND WARRANTIES OF ANY KIND WHATSOEVER WHETHER EXPRESSED IMPLIED OR STATUTORY INCLUDING WITHOUT LIMITATION ANY IMPLIED WARRANTIES OF MERCHANTABILITY PARTICULAR PURPOSE NONINFRINGEMENT OR ACCURACY ADEQUACY OR COMPLETENESS OF DATA MEASUREMENT WITH RESPECT TO ANY EQUIPMENT COMPONENTS PARTS CONSUMABLES SOFTWARE OR SERVICES SOLD TO BUYER BY SELLER THAT ARE NOT MANUFACTURED OR PROVIDED BY SELLER Seller shall assign the manufacturer s or service provider s warranty appl
7. a R HMETENT OVER TC 1 NEAT TC i OVER TC D WENT TC Small Font i ca d Ken 7 3 mm SZ ot OVER TC 1 D 22 liii Medium Font U 5 OVER Large Font To change channel display size from the Home Screen 1 NQURWHN Press Use Press Use Use Press Press to enter the Main Menu to highlight Setup Menu to enter the Setup Menu to highlight Channel Size to choose the desired channel size once to return to the Main Menu again to return to the Home Screen Data Logger Manual O Change Channel Units Channels can be customized to display readings in a variety of convenient units Units available for selection will vary according to channel type EMRELED WISIELE HE MIA HES Man Note Changing display units will not affect logged data To change channel display from the Home Screen 1 Press to view first channel screen 2 Use to view additional channels 3 On desired channel screen use to highlight Units 4 Use to choose the desired unit option 5 Press to return to the Home Screen OR 1 Use to highlight desired channel 2 Press to view channel screen 3 Use to highlight Units 4 Use to choose the desired unit option 5 Press to return to the Home Screen Note Hit X to update all channels Page 9 MadgeTech OctTemp2000 PE Statistics Statistical information is generated based on the data measured by each channel
8. able disable channels in the software 1 In the Device drop down menu select Identify Device and Read Status to view the Device Status screen Select the Device Detail tab Click Enabled Channels to show the Enabled Channels Screen To edit the enabled channels click Change Check the boxes next to channels to be enabled Click Save to save changes Click OK to return to the Device Detail screen Click OK to return to the software s main screen GG AO Hu Ek o H BI Enabled Channels Channel Names Channel Names Iw Thermocouple 1 Oven TC 1 Thermocouple 2 Men TC 1 Iw Thermocouple 2 ven TC 2 Iw Thermocouple 4 Vent TC 2 Page 15 MadgeTech OctTemp2000 E fli Device Detail TTT n Device Status Device Detail Device Power OctT emp Eight Channel Thermocouple Recorder Revision REV4 8192K Subtype 0x00000000 Channel 1 Ambient Temperature Measurement Units Measurement Range Measurement Resolution 0 01 Channel 2 Thermocouple 1 Measurement Units Measurement Range Measurement Resolution 0 000001 Measurement Units Measurement Range Measurement Resolution 0 01 Enabled Channels Channel Names Set Password Thermocouple Type Calibration Print Notice that disabled thermocouple and ambient channels appear grayed out on the Device Detail screen Page 16 Data Logger Manual E Name C
9. ading Page 12 Data Logger Manual CC Cal Date Date of last device calibration Cal Due Date device is due for recalibration Note It is important to keep your device properly calibrated to ensure accurate readings Contact MadgeTech for further information regarding calibration services Device Setup Menu Functions in the Device Setup Menu allow you to change home screen display and battery options To access the Device Setup Menu from the Home Screen 1 Press to enter the Main Menu 2 Use to highlight Setup Menu 3 Press to enter the Setup Menu CHRNNEL IZE UFORTE gt C REEN UFORTE AFTER AUTOSCROLL DISFLAY ERCRKLIGHT Channel Size Options for channel font size displayed on Home Screen Use to select font size Small up to six channels displayed on Home Screen Medium up to three channels displayed on Home Screen Large up to two channels displayed on Home Screen Update Screen Frequency of Home Screen Update Use to select Auto Home Screen updates at user defined interval Reading Home Screen updates each time a reading is taken Update After User defined Home Screen update frequency Use to set desired frequency Auto Scroll When device is idle screen view alternates between home and statistics screens Use to Enable Disable auto scroll Page 13 MadgeTech OctTemp2000 Wee Display Options for display visibility Use to select Auto display turns o
10. al sales service and support you may contact our office directly Madgeflech Inc 879 Maple Street Contoocook NH 03229 PO Box 50 Warner NH 03278 Tel 603 456 2011 Fax 603 456 2012 info madgetech com Page 2 Data Logger Manual CC Introducing the OctTemp2000 Device Overview 9 12VDC Communications Directional Status Input Port P GE Key Pad q Y Mounting Holes Channel Cancel Key Inputs Keypad Functions OK Key Cancel Key Up Down Directional Keys Left Right Directional Keys Page 3 MadgeTech OctTemp2000 Display Overview Screen Title KO BEE S 23 ie d K Status st S Indicators Fi E 4 H SESCH ka OVEN TC 1 Content E D e T T winnen Status Indicators Battery Power Full Half full Empty Memory Remaining Empty Half full Full Device is running Device is stopped Delay Start Push button Manual Start Device reset has occurred s E be L 0 o External power present Page 4 Data Logger Manual Specifications Internal Temperature Channels Range 20 to 60 C Resolution 0 1 C Accuracy 0 5 C 0 to 50 C Thermocouple Channels Types J K T E R S B and N Connection Female sub minature SMP Cold Junction Compensation Automatic based on internal channel Maximum Thermocouple Resistance 1000Q lt 100Q re
11. anual CC Battery Information A BATTERY WARNING This data logger contains a lithium battery Do not cut the battery open incinerate or recharge Do not heat lithium batteries above the specified operating temperature Dispose of the battery in accordance with local regulations See the individual specification sheets at www madgetech com Battery Replacement This product does not have any user serviceable parts except the battery which should be replaced periodically The battery life is affected by battery type ambient temperature sample rate sensor selection off loads and LCD usage The device has a battery status indicator on the LCD If the battery indication is low or if the device seems to be inoperable it is recommended that the battery be replaced To replace the battery locate the battery compartment cover on the back of the unit Remove the two 2 3 32 hex screws and expose the battery compartment Use the pull tab to remove battery from compartment Remove the old 9V battery from the battery clips and replace with a new 9V battery We recommend using 9V lithium battery An alkaline battery is acceptable but will yield a shorter battery life i L Page 19 MadgeTech OctTemp2000 W Computer Interface STEREO PLUG CONNECTS WITH COMMUNICATIONS JACK LOCATED HERE FC200 d USB CABLE egene TO USB PORT ON YOUR PC Fully insert the male connector of the IFC200 interface ca
12. ble into the female receptacle of the data logger Fully insert the female USB connector into the USB Please see the Data Logger Software manual for further information WARNING Install driver before connecting a device using a USB for the first time See the Software manual for further information Page 20 Data Logger Manual Warranty Products manufactured by Madgelech Inc are warranted against defective material and workmanship for a period of one year starting from the date of shipment In the event that a MadgeTech product is found to be defective MadgeTech will repair or replace the product at its sole discretion Such repair or replacement shall be the sole remedy of this warranty This warranty extends only to the original purchasing customer and does not apply to any unit which in our sole judgment has been subjected to a Operating or environmental conditions in excess of our written specifications or recommendations b Damage misuse or neglect c Improper installation repair or alteration This warranty excludes batteries Except as to title this is our only warranty for the products MadgeTech Inc expressly disclaims all other warranties guarantees or remedies whether expressed or implied or statutory including any implied warranty of merchantability or fitness for a particular purpose We also disclaim any implied warranty arising out of trade usage or out of a course dealing or course of p
13. commended Thermocouples Type Range Resolution Accuracy J 200 to 760 C 0 1 C 0 5 C K 200 to 1370 C 0 1 C 055 T 200 to 400 C G I 0 5 C E 200 to 980 C 0 1 C FOSC R 50 to 1760 C 0 1 C 2 0 C S 50 to 1760 C 0 1 C EZO B 50 to 1820 C 0 1 C 200C N 200 to 1300 C 0 1 C S Dot Matrix LCD Dimensions 2 5 x 1 375 63mm x 35mm Text Configurable channel text size Indicators Power status memory Backlight Configurable with auto shut off and contrast adjustment Start Stop Modes Software programmable start time and date up to six months in advance or manual push button start Programmable stop time Memory 500 000 readings per channel with all channels enabled 4 000 000 total readings software configurable memory wrap Reading Rate 4 readings per second 4Hz up to 1 reading every 24 hours Page 5 MadgeTech OctTemp2000 W Calibration Digital calibration through software Calibration date automatically recorded within device NIST traceable certificate available Power Supply Primary Source 9V lithium or alkaline battery user replaceable Secondary Source 7 5 24V DC external 100mA max Battery Life Eighteen month battery life with display off Three months typical with continuous display use Data Format Time and date stamped C F K R uV mV V Time Accuracy 1 minute per month
14. e software as well as the manual s and printed materials provided by Seller B Seller grants Buyer a non exclusive non transferable license to use the Software in object code form only according to the terms set forth below Buyer may operate the Software only i in conjunction with and as part of the Product ii in the manner in which it is intended by Seller and iii at Buyer s plant site where the Product is first used Buyer may negotiate with Seller separate licenses to use the Software at other plant sites Buyer s use of Software shall be governed exclusively by Sellers and or an third party owner s applicable license terms C Buyer shall not i make the Software available to any person or entity other than its Page 23 MadgeTech OctTemp2000 Smm employees who must use the Software only as specified above ii modify the Software or merge it with another program ili reverse engineer disassemble decompile or make any attempt to discover the source code of the Software iv translate or create derivative works based on the Software v remove obscure or alter any notice of the patent copyright or other proprietary rights related to the Software vi sub license sell lend rent or lease any portion of the Software vii copy any portion of the Software viii operate the Software other than in conjunction with operation of Product or ix transfer the Software in violation of applicable United States Exp
15. ects that are found by Seller or repair or replace F O B point of manufacture that portion of the Seller manufactured Products consumables or Software found by Seller to be defective or refund the price of the defective portion of the Seller manufactured Products consumables or Software or of the defective portion of the Seller provided services All replacements or repairs necessitated by inadequate maintenance normal wear and usage unsuitable pow er sources unsuitable environmental conditions accident misuse improper installation modification repair storage or handling or any other cause not the fault of Seller are not covered by this limited warranty and shall be at Buyer s expense Seller shall not be obligated to pay any costs or charges incurred by Buyer or any other party except as may be agreed upon in writing in advance by an authorized representative of Seller All costs of disman tling re installation and freight and the time and expenses of Seller s personnel for site travel and diagnosis under this limited warranty shall be borne by Buyer unless accepted in writing by Seller Seller manufactured Products consumables and Software and Seller provided services repaired replaced or corrected during the applicable warranty period shall be in warranty for the greater of the remainder of the applicable original warranty period or ninety 90 days THE FOREGOING STATES THE SOLE AND EXCLUSIVE WARRANTY AND LIABILITY OF SELLE
16. erformance We do not guarantee the integrity of data or warranty that the products will operate uninterrupted or error free Madgelech data loggers and their associated software have been thoroughly tested and the documentation reviewed However MadgeTech does not warrant the performance of its products or that the products or their associated software will operate as described in this manual Page 21 MadgeTech OctTemp2000 W Terms and Conditions All products furnished by MadgeTech Inc Seller shall be in accordance with the following terms and conditions unless otherwise stated in writing These Terms and Conditions Terms and Conditions govern a all sales quotations and sales of components equipment parts and other products Product from and b all service proposals and provisions of services by Seller to the buyer of the Products Buyer These Terms and Conditions shall take precedence over any terms and conditions which appear on Buyer s order or other form or any other writing or electronic transmission from Buyer Any terms or conditions on any of Buyer s forms recordings electronic transmissions or orders that are different from or in addition to these Terms and Conditions are specifically rejected Any modification to these Terms and Conditions must be agreed to and executed in writing by Seller Sellers failure to object to provisions contained in any communication from Buyer shall not be
17. ff after two minutes of inactivity On display always on Backlight Options for use of display backlight Use to select Auto backlight turns off after five seconds of inactivity On backlight always on Off backlight always off LED Options for use of status LEDs Use to select Enabled status LEDs flash to indicate reading status Disabled LEDs off Contrast Set screen contrast value Use to set desired contrast value Battery Type User defined based on the type of battery currently installed in the device Use to select Lithium or Alkaline battery Battery Life Percentage of battery power remaining Battery Voltage Voltage supplied to the device by the battery External Power Presence of external power supply External Voltage Voltage supplied to the device by external power supply Page 14 Data Logger Manual CC Software Features This section details several features of the data logger software that are particularly useful with the Octlemp2000 device For further information regarding the software please consult the Data logger Software Manual available at www madgetech com Enable and Disable Channels The user may choose to enable or disable channels using the software Data from disabled channels will be visible on the LCD but readings will not be recorded to the device s memory Disabling a thermocouple channel also disables it s corresponding ambient temperature channel To en
18. hannel Each channel can be given an unique name for easy identification Channel names are visible on the LCD and are used throughout the software and data files To name channels in the software 1 In the Device drop down menu select Identify Device and Read Status to view the Device Status screen Select the Device Detail tab Click Channel Names to show the Channel Names Screen To edit the channel names click Change Type desired channel name in text box next to each channel Click Save to save changes Click OK to return to the Device Detail screen Click OK to return to the software s main screen CON WN BW K li Device Detail geecssecccccesesecsenssscscsosssesee al Device Status Device Detail Device Power OctT emp K Eight Channel Thermocouple Recorder Revision REV4 8192K Subtype 000000000 Channel 1 Ambient Temperature Measurement Units Measurement Range Measurement Resolution 0 01 Channel 2 Thermocouple 1 GE EE Measurement Units Thermocouple Measurement Range aa ype Measurement Resolution 0 000001 SS T E Calibration Channel 3 Ambient Temperature Measurement Units 4 l Print Measurement Range 20 Measurement Resolution 0 Ta EE 0 li Channel Names Channel Names Names Oven TE Thermocouple 1 Name Vent TC 1 Thermocouple 2 Name Change Oven TC2 Thermocouple 3 Blaha Vent TC Thermocouple 4 Blah Save
19. icable to such equipment components parts consumables Software and services to the extent permitted to Buyer Seller will provide Buyer with available warranty information 21 Limitations IN NO EVENT REGARDLESS OF THE FORM OF THE CLAIM OR CAUSE OF ACTION WHETHER BASED IN CONTRACT INFRINGEMENT NEGLIGENCE STRICT LIABILITY OTHER TORT OR OTHERWISE SHALL SELLER S LIABILITY EXCEED THE PRICE ACTUALLY PAID BY BUYER TO SELLER FOR THE SPECIFIC PRODUCTS CONSUMABLES AND OR SOFTWARE MANUFACTURED AND OR SERVICES PROVIDED BY SELLER GIVING RISE TO THE CLAIM OR CAUSE OF ACTION SELLER SHALL NOT UNDER ANY CIRCUMSTANCES BE LIABLE FOR ANY LOSS OF REVENUE LOSS OF PROFITS OR ANY INCIDENTAL INDIRECT SPECIAL EXEMPLARY OR CONSEQUENTIAL DAMAGES WHETHER OR NOT FORESEEABLE NO AC TION REGARDLESS OF FORM ARISING OUT OF ANY TRANSACTION GOVERNED BY THESE TERMS AND CONDITIONS MAY BE BROUGHT BY EITHER PARTY MORE THAN TWO 2 YEARS AFTER THE CAUSE OF ACTION HAS ACCRUED The foregoing allocation of risk and limitation of liability has been agreed to by the parties and forms the basis of their willingness to enter into any accepted order 22 Software License A For purposes hereof Software means the computer programs included in the Product at delivery together with all codes techniques software tools formats designs concepts methods and ideas associated with those computer programs The term also includes all copies of any part of th
20. o highlight Start Device 3 Press to select Start Device 4 Press to confirm device start press to cancel Page 11 MadgeTech OctTemp2000 W Device Menus Device Status Menu Information such as current recording status reading rate stop date and time and calibration information can be found in the Device Status Menu To access the Device Status Menu from the Home Screen 1 Press to enter the Main Menu 2 Use to highlight Status 3 Press to enter the Device Status Menu STATUS MEMORY LEFT READINGS RATE B seconds Disabled Status Device s current recording status Running device is actively recording data Stopped device is not actively recording data Delay device is in Delay Start mode start scheduled for future Manual device is in Manual push button Start mode Memory Left Percentage of memory available to store readings Readings Number of readings currently stored in device s memory Rate Reading rate configurable using data logger software Wrap Memory wrap configurable using data logger software Enabled when memory is full device will overwrite oldest data Disabled when memory is full device will stop recording data Start Date Time Date and time device began recording data Stop Date Time Date and time device will stop recording data due to full memory or other user configured parameter Reading Date Time Date and time of last recorded re
21. ort laws and regulations Page 24 879 Maple Street e Contoocook NH 03229 Phone 603 456 2011 e Fax 603 456 2012 www madgetech com e info madgetech com