Home
        User`s Manual
         Contents
1.   ME Fast Response Sensors and Systems       Precision Measurement Engineering  Inc  e www pme com    User   s Manual    2014       miniDOT    Precision Measurement Engineering  Inc  1   760  727 0300  www pme com    Warranty    1 YEAR LIMITED WARRANTY ON miniDOT HARDWARE    Precision Measurement Engineering  Inc   PME  warrant that the miniDOT Logger  shall be free of defects in workmanship and materials  under normal use  for a period  of one year from the date of shipment  This warranty is made only to the original  purchaser  In the event a miniDOT Logger covered by this warranty fails to operate  according to our published specifications  then return it freight pre paid to PME or an  authorized Service Provider  PME will repair the unit at no charge to the customer  and bear the cost of return shipment  Carefully pack all components  as the customer  is responsible for any freight damage     This warranty does not apply to services or consumable   expendable items  such as  batteries  fuses and ropes  required for general maintenance  Equipment  manufactured by other companies  such as meteorology sensors  solar panels  etc   are warranted only to the limit of the warranties provided by their original  manufacturer     PME makes no warranty  either expressed or implied  that the sensors will be  operable after they are exposed to adverse environmental conditions  such as bio   fouling  oil fouling  freezing temperatures or others     This warranty is void if  in our opin
2.   www pme com  Made in the USA       3 3 Electrical Connections and Controls    Removal of the cover reveals the logger connections and controls  shown below     Logger Control Switch LED Light    USB Connection       The LED Light is a LED that can display either red or green light  This is used to  indicate different features described in Chapter 1 in this manual     The Logger Control Switch controls the logger mode     e Record    When the switch is in this position the logger is recording  measurements    e Halt    When the switch is in this position the logger is not recording and is  sleeping at low power     The USB Connection allows communication between the logger and an external  host computer  When connected  the logger is in halt mode regardless of the Logger  Control Switch position  When disconnected the logger mode is controlled by the  switch position  The switch position may be changed while the USB is connected     Precision Measurement Engineering  Inc  20   760  727 0300  www pme com    The Main Batteries  2 X AA on side opposite to pictured side above  provide main  power to the miniDOT Logger  Note the positive     terminal  Batteries are  described in Chapter 1 of this manual     3 4 Battery Replacement    Be sure that the replacement battery is compatible with minIDOT  PME recommends  Energizer L91 AA size lithium batteries or Duracell AA size alkaline batteries     http   data energizer com PDEFs  91 pdf    http   ww2 duracell com media en   US pdf g
3.  com    2 4 miniDOTConcatenate    Begin program operation by clicking on miniDOTConcatenate jar  Software presents  the screen shown below     CE iclx    LX PN f ME Fast Response Sensors and Systems       Surface Elevation  meters   0 00        Elevation    Barometric Pressure  Salinity  ppt  10 00    Select DATA Folder   none selected                miniDOTConcatenate reads and concatenates the files recorded by the miniDOT  Logger  Software produces CAT txt in the same folder as selected for the data   CAT txt contains all the original measurements and contains two additional  statements of time and oxygen saturation  To compute saturation  software must  know the air pressure and salinity  It calculates air pressure based on elevation of  the water surface above sea level or uses the barometric pressure you enter if  Barometric Pressure is selected  If Elevation is entered  no compensation for  weather induced barometric pressure variation is made  Enter elevation or  barometric pressure  Enter water salinity     Select the folder that contains the files recorded by miniDOT  If miniDOTPlot is run  directly from the miniDOT the program will suggest the folder located on the  miniDOT  You may accept this by clicking on Process  or you may click on Select  Data Folder to browse to your computer   s hard drive  If the number of measurments  recorded is small  say a few thousand  these can conveniently be plotted directly from  miniDOT storage  However it is best to copy large 
4.  it  to a host device via USB  The miniDOT Logger will appear as a    thumb drive     Your  temperature and oxygen concentration measurements  together with a time stamp  indicating the time the measurement was made  are recorded in text files in the folder  having the serial number of your miniDOT Logger  These files can be copied onto  any Windows or Mac host computer     This Manual and other software is also recorded on the miniDOTLogger    e miniDOTControl allows you to see the state of the logger as well as set the  recording interval    e miniDOTPlot allows you to see plots of the recorded measurements    e miniDOTConcatenate gathers all the daily files into one CAT txt file     Your miniDOT Logger will return to recording measurements after you disconnect the  USB connection  If you wish to stop recording  switch the Recording Control Switch  to the Halt position     You may switch the Recording Control Switch at any time    Follow these steps to start the deployment  logging DO  amp  T once each 10  minutes    1  Open the miniDOT Logger by unscrewing the white housing from the black end    cap  it opens like a flashlight   Remove the housing completely  Inside you will  see the circuit pictured below     Logger Control Switch LED Light    USB Connection       Precision Measurement Engineering  Inc  5   760  727 0300  www pme com    2  Switch the Logger Control Switch to the Record position  The LED will flash  green 5 times  The miniDOT Logger will now record a measu
5.  miniDOT     If the 3 requirements are met  then connect miniDOT to your device  You should see  the miniDOT green connection light come on and your device display a message  about  preparing USB storage   When  USB storage ready  is shown  use your  file  explorer  program to move your data from the miniDOT onto you device     Again  it is highly recommended that you try this operation at your work station prior  to depending upon this in the field     Currently the associated miniDOT programs  Control  Plot  and Concatenate  are not  supported by Android devices     Precision Measurement Engineering  Inc  13   760  727 0300  www pme com    Chapter 2  Software    2 1 Overview and Software Installation  The miniDOT arrives with these files     e MiniDOTControl jar allows you to see the state of the logger as well as set the  recording interval    e MiniDOTPlot jar allows you to see plots of the recorded measurements    e MiniDOTConcatenate jar gathers all the daily files into one CAT txt file    e Manual pdf this manual     These files are located on the root directory of the miniDOT     PME suggests you leave these programs where they are on the miniDOT  but you  may copy them to any folder on your computer s hard drive     MiniDOTControl  miniDOTPlot  and miniDOTConcatenate are Java language  programs that require the host computer to have the Java Runtime Engine V1 7   JRE  or later installed  This engine is commonly required for internet applications  and will likely alre
6.  occasionally to a host having an  internet connection  The miniDOTControl program will automatically set time based  on an internet time server     Please refer to Chapter 2 for instructions on operating the miniDOTControl program     File Information     The miniDOT Logger software creates 1 file daily on miniDOT   s  internal SD card  The number of measurements in each file will depend upon the  sample interval  Files are named by the time of the first measurement within the file  based on the logger   s internal clock and expressed in YYYY MM DD HHMMSSZ txt  format  For example a file having the first measurement on September 9  2014 at  17 39 00 UTC will be named    2014 09 09 173900Z  txt     Files can be uploaded from miniDOT by connecting miniDOT to a host computer and  by using the host computer to copy paste the files from miniDOT to some host  computer storage     Each measurement within files has a time stamp The time stamp format is Unix  Epoch 1970  the number of seconds that have passed since the first moment of  1970  This may be inconvenient in some cases  If so  the miniDOTConcatenate  software not only concatenates all the measurement files but also adds more  readable statements of the time stamp     Please refer to Chapter 2 for instructions on operating the miniDOTConcatenate  program     miniDOT requires time and battery energy to work through the file directory on SD  card to allocate new file space  A few hundred files on SD is not a problem but as th
7.  of the o ring  When the pressure housing is  screwed back on these drops become trapped inside the miniDOT Logger  Be sure  to carefully dry the o ring and adjacent surfaces  especially underneath  prior to  closing the miniDOT  Re lube the o ring at this time     LED Indications     The miniDOT Logger indicates its operation with its LED  The  table below presents LED indications     Precision Measurement Engineering  Inc  10   760  727 0300  www pme com    LED Reason  1 Green Normal  Presented immediately after new batteries are  Flash installed  Indicates that the CPU has started its program     1 Green Occurs at the time of sampling for sample intervals of 1 minute  Flash or less     5 Green Normal  Indicates that miniDOT is beginning to record  Flashes measurements  This indication appears in response to    switching the Recording Control Switch to Record   5 Red Normal  Indicates the miniDOT is ending recording of  Flashes measurements  This indication appears in response to  switching the Recording Control Switch to Halt     Continuously   Normal  Indicates the miniDOT is connected to a host device  Green via USB     Continuously   SD card write error  Try removing reinstalling batteries   Flashing Red   Contact PME        Verifying Calibration     You may from time to time want to verify the calibration of  your miniDOT  Do this by placing the miniDOT in a black 5 gallon bucket containing  4 gallons of fresh   The picture below shows a white bucket so that miniDOTs a
8. ady be installed on the host computer  You can test this by running  miniDOTPlot  If this program displays its graphical user interface then the JRE is  installed  If not then the JRE can be downloaded via internet from    http   www java com en download windows_xpi jsp       At this time miniDOT Logger is supported on Windows operating systems  but may  also operate on Macintosh and perhaps Linux     2 2 miniDOTControl    Begin program operation by clicking on miniDOTControl jar  Software presents the  screen shown below     Precision Measurement Engineering  Inc  14   760  727 0300  www pme com     ioix    LX AN f ME Fast Response Sensors snd Systems    Logger Status    k Connect         The miniDOT must be connected to USB at this time  When correctly connected the  miniDOT LED will display a constant green light     Click the Connect button  The software will contact the logger  If the connection is  successful the button will turn green and display    Connected     The Serial Number  and other parameters will be filled in from information taken from the miniDOT     If the host computer is connected to the internet  the current difference between an  internet time server   s time and the miniDOT Logger internal clock will be displayed   And  if more than a week has passed since time was last set  the miniDOT clock will  be set and check mark icon will appear  If the host computer is not connected to the  internet no time services will occur     The current miniDOT Logger 
9. ariation is made  Enter elevation or  barometric pressure  Enter water salinity     Select the folder that contains the files recorded by miniDOT  If miniDOTPlot is run  directly from the miniDOT the program will suggest the folder located on the miniDOT  SD card  You may accept this by clicking on Process  or you may click on Select  Data Folder to browse to your computer   s hard drive  If the number of measurements  recorded is small  say a few thousand  these can conveniently be plotted directly from  miniDOT storage  However it is best to copy large measurement sets to the host  computer and select them there since file access to miniDOT is slow     miniDOT measurement folders must NOT contain any files besides those miniDOT  records and the CAT txt file     Press Plot to begin plotting     Precision Measurement Engineering  Inc  16   760  727 0300  www pme com    The software reads all miniDOT Logger data files in the selected folder  It  concatenates these and presents the plot shown below    miniDOT Logger Measurements  7392 746840                             1 0 2 5  3 9    100    8 8  78  t90 M lon  8 74 o     80       8 61 araa          A  70 wa    gt  8 5     26    2  2 25  amp   a a t60 Q 6 lang 8    8 4     D      D at 5    8 3  3 21 so OSS jL      Oo   he   4 FALSI  lt   O82  8 t4o    p04 T     24  pico   8 14 D t30    3 LO  8 0 7  gt    0 75  E  20 0 P     7 9 0 50  78  gt  gt     10 0 1 0 25  m     0    0 0  0 00  10 Sep 11 Sep  Local Time           Temperatu
10. e  number of files grows large into the thousands miniDOT may suffer decreased  battery life or other performance problems  Please  at the earliest convenient time   copy recorded files to a host computer and delete them from miniDOT  Also  do not  use miniDOT to store files unrelated to miniDOT operation     Precision Measurement Engineering  Inc  7   760  727 0300  www pme com    Cleaning the Sensing Foil    The sensor can be cleaned at regular intervals  depending on the fouling condition at the site  The cleaning procedure of the sensor  spots should be done with caution so that the protective coating is not removed  If the  fouling is calcareous it can normally be dissolved with household vinegar     If the marine growth remains  then use Q tips to gently wipe it off after it has been  softened by soaking in vinegar or perhaps dilute HCI  After cleaning the sensor it   should be rinsed well in clean tap water before storing or reuse  Do not use other  organic solvents such as acetone  chloroform  toluene since these and others will  damage the foil     The sensor membrane can also be cleaned using a 3  H202 solution or rinsing it  with ethanol     The plastic case of the miniIDOT Logger can be gently scrubbed     AA Alkaline Battery Life     Alkaline batteries will give somewhat less performance  than lithium  especially at low temperatures  Alkaline batteries are superior to lithium  in one way  you can guess how much battery life remains from measurements of the  batte
11. eep the black end covered with  the cap supplied by PME  If the cap is lost  cover the end with aluminum foil  There  may be a calibration effect of ambient lighting so attempt to keep ambient light from  reaching the sensing foil as much as possible     Java     miniDOT programs depend on Java and require Java 1 7 or higher  Update  Java at    https   java com en download index jsp    Precision Measurement Engineering  Inc  12   760  727 0300  www pme com    Upload Files to an Android device     It is possible to transfer your measurement  files from miniDOT to your android device  This operation has 3 prerequisites     1  An Android device equipped with USB On The Go  OTG   OTG is a feature on  most modern Android devices that allows them to act as a USB host  OTG was  introduced with Android version 3 1 and should be a useable feature on most  devices  It is still possible that your device doesn t support OTG  Please test your  device with a miniDOT prior to attempting to upload while in the field     2  A USB OTG cable  This is essentially an adapter with a micro USB connector on  one end that connects to your Android device and a standard A type USB plug on  the other  The cable supplied with miniDOT connects to this end     3  A  File Explorer  app downloaded on your Android device  These types of apps  assist with being able to view and move files from device to device   ES File  Explorer  is a free app available on the Google app store and is recommended for  use with
12. especially before any long  months   measurement deployment     Precision Measurement Engineering  Inc  8   760  727 0300  www pme com    Monitor battery terminal voltage  You cannot tell from terminal voltage of a lithium  battery how long the battery will last  but you can tell if it will die sometime really  soon  The Low Drain Performance plot below gives an estimate of terminal voltage  for both lithium and alkaline batteries  Your measured voltage will be 2X what is  shown below since there are two batteries in series within the miniDOT  You can  operate batteries down to about 2 4 Volts  for two in series  1 2 Volts on the graph  below   Measure the series voltage as shown in the picture below  Your batteries  are dead if this measurement is less than 2 4 Volts        You may also use alkaline AA batteries such as Duracell Coppertop  They will not  last nearly as long  especially at low temperatures  but will likely be adequate for  several weeks at 10 minute interval     When replacing batteries use only fresh batteries  Don   t mix battery types  If one  battery differs in type or charge level from the other and the miniDOT runs them to full  discharge  one battery may leak     Err on the side of caution when planning your deployment     The recommended battery is Energizer L91  See this link for information including  performance at low temperatures     http   data energizer com PDFs 191 pdf    The figure below gives a very general idea of terminal voltage vs lifeti
13. ion  the miniDOT Logger has been damaged by  accident  mishandled  altered  or repaired by the customer  where such treatment has  affected its performance or reliability  In the event of such treatment by the customer   costs for repairs plus two way freight costs  no COD shipments will be accepted  will  be borne by the customer  In such cases  an estimate will be submitted for approval  before repair work is started  Items found to be defective should be returned to PME  carefully packed  as the customer will be responsible for freight damage     Incidental or consequential damages or costs incurred as a result of the product  malfunction are not the responsibility of PME     For all warranty or non warranty returns please obtain  complete  and submit a RMA  to PME  This RMA form may be obtained at    http  Awww pme com HTML 20Docs RMAform html     After submission of this form  then PME will respond with a RMA number  Please  place this number on all shipments and related communications     Precision Measurement Engineering  Inc  2   760  727 0300  www pme com    Safety Information    BURSTING HAZARD    Should water enter the miniDOT Logger and come into contact with the enclosed  batteries  the batteries may generate gas causing the internal pressure to increase   This gas will likely exit via the same location where the water entered  but not  necessarily  The miniDOT Logger is designed to release internal pressure as the end  cap is unscrewed  prior to the disengagemen
14. ired to open the logger  each time measurements are transferred to the host computer  This chapter  describes the logger internal features     3 2 Opening and Closing the Logger    The logger circuitry is contained in a waterproof housing that must be opened  The  housing is opened by unscrewing the white pressure housing from the black end cap   in a way similar to the opening of a flashlight  Turn the pressure housing counter  clockwise relative to black end cap  Close by reversing this procedure after being  sure that the o ring is free from debris  Lube o ring occasionally with grease intended  for buna N o ring material     Please attempt to handle the miniDOT only by the aluminum chassis  without  touching the circuit card     When closing the miniDOT inspect the o ring and interior of the white cylinder for  debris  lube the o ring  and screw the white cylinder onto the black end cap until the  cylinder just touches the end cap  Do not tighten  miniDOT tends to get a little tighter  during depolyment     If you can not open miniDOT by yourself  find another person with strong hands  This  person should grip the black end cap while the other person turns the white cylinder     Caution  Do NOT remove the stainless screws in the black end cap  If this is done  the miniDOT will be permanently damaged and must be returned to be repaired     Precision Measurement Engineering  Inc  19   760  727 0300  www pme com    PME    Fast Response Sensors and Systems    miniDOT Logger  
15. me  Service life  in hours is incorrect since miniDOT draws far less than 50 mA continuously but the  general shape of the voltage vs time gives an estimate of life remaining  This plot is  taken from the manufacturer s specification  The plot is for a single battery  Double  the voltages shown to give the terminal voltage as measured in the picture above   miniDOT halts operation at a total of 2 4 Volts     Precision Measurement Engineering  Inc  9   760  727 0300  www pme com    Low Drain Performance             50mA Continuous  21  C     AA Lithium AA Alkaline   1 6   gt  1 4  O    1 2  Co   f     S 1 0       gt  0 8   0 15 30 45 60 75    Service  hours     Coin Cell Battery Life     The miniDOT Logger uses a coin cell for backup of the  clock when the power is switched off  This coin cell will supply many years of clock  operation  Should the coin cell discharge it must be replaced by PME  Contact  PME     Recalibration     The miniDOT Logger will maintain its calibration without the  necessity of adjustment by the user  Loggers should be returned to PME for  recalibration  We suggest that this be done every  2 million samples     O Ring and Seal     When the cover is screwed on  it passes along the o ring located  in the end cap several revolutions  Keep this o ring lightly lubricated with silicone  grease or oil compatible with buna N o ring material     When the miniDOT Logger is opened after deployment  a small number of water  drops are deposited on the inner surface
16. measurement sets to the host  computer and select them there since file access to miniDOT is slow     miniDOT measurement folders must NOT contain any files besides those miniDOT  records and the CAT txt file     Press Concatenate to begin concatenating files and create the CAT txt file     The CAT txt file will resemble the following     Precision Measurement Engineering  Inc  18   760  727 0300  www pme com    2 Sensor  7392 0002  3 Concatenation Date  2014Jun30 10 20 40 PDT    5 DO concentration compensated for salinity  0 0  ppt   6 Saturation computed at elevation  0 0  meter     Unix Timestamp  UTC _Date_ amp _ Time  Pacific Standard Time  Battery    Second    none    none    Volt    1402942957  2014 06 16 18 22 37  2014 06 16 11 22 37  3 310000   1402942959  2014 06 16 18 22 39  2014 06 16 11 22 39  3 320000   1402942961  2014 06 16 18 22 41  2014 06 16 11 22 41  3 320000   1402942963  2014 06 16 18 22 43  2014 06 16 11 22 43  3 320000   140279427945 2N14 NF 14 18 27 45 2N14 NA 1h 11 77 45 2 22NNANn    End miniDOTConcatenate by closing the window     Chapter 3  miniDOT Logger    3 1 Overview    All of the miniDOT Logger measurements pass from the sensors into files on the SD  card miniDOT contains  Files are transferred to a host computer via USB connection  where miniDOT appears as a    thumb drive     Measurements may be plotted by  miniDOTPlot and files concatenated by miniDOTConcatenate  The miniDOT Logger  itself is controlled by miniDOTControl  Customers are requ
17. rding after USB disconnection    11  Disconnect the miniDOT Logger from the USB connection    12  Inspect the o ring seal for debris    13 Close the miniDOT Logger by screwing the white housing back onto the black end  cap     x    6    x    Remove the batteries if storing the miniDOT Logger for extended periods     1 2 A Few Details    The previous section gives instructions for sampling at 10 minute intervals  However  there are a few additional details that will enhance use of the miniDOT Logger     Precision Measurement Engineering  Inc  6   760  727 0300  www pme com    Recording Interval     The miniDOT Logger measures and records time  battery  voltage  temperature  dissolved oxygen concentration and measurement quality at  equal time intervals  The default time interval is 10 minutes  However  it is also  possible to instruct the miniDOT Logger to record at different intervals  This is  accomplished by running the miniDOTControl jar program supplied with the miniDOT   Recording intervals must be 1 or more minutes and must be less than or equal to 60  minutes  Intervals outside this range will be rejected by miniDOTControl   Contact  PME for other recording intervals      Please refer to Chapter 2 for instructions on operating the miniDOTControl program     Time     All miniDOT times are UTC  formerly known as Greenwich mean time   GMT    The miniDOT Logger internal clock will drift in the  lt 10 ppm range   lt  about  30 seconds month  so you should plan to connect it
18. re     Dissolved Oxygen     DO Sat     Q     Battery    You may zoom this plot by drawing a square from upper left to lower right  click and  hold left mouse button  that defines the zoom region  To zoom completely out   attempt to draw a square from lower right to upper left  Right click on the plot for  options such as copy and print  The plot can be scrolled with the mouse while the  Control key is held depressed  Copies of the plot can be obtained by right clicking on  the plot and selecting Copy from the pop up menu     Different DATA Folders can be selected during one session of the program  In this  case the software produces multiple plots  Unfortunately the plots are presented  exactly on top of each other and so when a new plot appears it is not obvious that the  old plot is still there  Itis  Just move the new plot to see it     The software can be re run at any time  If an already processed DATA Folder is  selected the software simply reads the miniDOT Logger measurement files again     End miniDOTPlot by closing the window     Special note  plotting of sample sets of more than 200K samples may consume all  memory available to the JRE  miniDOTPIot will present a partial plot and freeze in  this case  A simple solution is to separate the files into multiple folders and plot each  folder individually  A special miniDOTPIot that sub samples can be provided by PME   Please contact PME in this case     Precision Measurement Engineering  Inc  17   760  727 0300  www pme
19. re  more easily seen   The miniDOT sensor end  black  is heavy and the miniDOT will  tend to flip so that this end is down  Prevent this somehow  miniDOT must be  placed in the bucket with the sensor end upwards  Otherwise bubbles will  accumulate in the sensing end and miniDOT will not sense water DO correctly  Use  an aquarium pump and air stone in the water to provide a bubble stream  Cover the  bucket with a black lid  The idea is to prevent light from enabling algal growth        Record measurements for several hours or a day but in any event long enough for  the miniDOT temperature to come to equilibrium with the water  During the  experiment find the local air pressure  either from measurements or from a local    Precision Measurement Engineering  Inc  11   760  727 0300  www pme com    weather station  Watch out    weather stations often report barometric pressure  referenced to sea level  You must determine the absolute barometric pressure at  your elevation     A more comprehensive experiment is to additionally place ice in the bucket  mixing  until the water temperature is close to zero degrees and then removing the ice  Place  the bucket on a towel or cardboard and cover with a towel  Record for 24 hours as  the bucket temperature gradually returns to room temperature     After recording the bubbled water  you may also remove the air stone and gently mix  a packet of baker   s yeast into the bucket together with a tablespoon of sugar  The  water must be only sligh
20. rement of time   battery voltage  temperature  and dissolved oxygen every 10 minutes  or at some  other interval you may have set using miniDOTControl     3  Inspect the o ring seal for debris    4  Close the miniDOT Logger by screwing the white housing back onto the black end  cap    5  Deploy the miniDOT Logger     Follow these steps to end the deployment    1  Recover the miniDOT Logger   2  Clean and dry all accessible surfaces except the    foil       3  Open the miniDOT Logger by unscrewing the white housing from the black end  cap  Remove the housing completely  taking care that water does not drip onto  interior surfaces of circuits or other items inside the logger    4  Connect to a Windows host computer via USB  miniDOT will appear as a    thumb  drive       5  Copy the folder having the same serial number as the miniDOT Logger  example   7392 0001  to the host computer     Suggested  but optional  Delete measurement folder  but NOT miniDOTControl   or the other  jar programs    7   Optionally  Run the miniDOTControl program to see the state of the miniDOT  Logger such as battery voltage or to select a different recording interval    8   Optionally  Run the miniDOTPLOT program to see a plot of measurements    9   Optionally  Run the miniDOTConcatenate program to gather together all the daily  files of measurements into one CAT txt file    10  If no more recording is desired  switch the Recording Control Switch to Halt   otherwise leave it set to Record to begin reco
21. ry terminal voltage  For short deployments of a month or two alkaline batteries  will provide adequate performance  For longer deployments  or for deployments in  cold environments  substitute lithium batteries     AA Lithium Battery Life     The miniDOT Logger consumes battery power mostly  from the measurement of dissolved oxygen  but also slightly from simply keeping  track of time  writing files  sleeping  and other activities  The following table presents  the approximate endurance of the miniDOT Logger when powered by the Energizer  L91 AA lithium   ferrous disulfide batteries     SAMPLE INTERVAL   Main AA Battery Life   minutes   months  Samples    500K   gt 52 000  a ee  gt 8 000    Keep a general record of miniDOT Logger number of samples  It is not possible to  accurately tell the charge state of a lithium battery from measurements of its terminal  voltage  If you have a general idea of the number of samples already obtained ona  battery  then you can make a guess as to how many more samples remain        The numbers in the table above are at the time of this writing are based upon  extrapolations of testing of 500K samples acquired at 5 second interval  The 1 year  performance at 1 minute is very likely  Performance at longer sample intervals will be  much longer but how long is difficult to predict  In any event  these AA batteries are  easily available and relatively inexpensive compared to the cost of the miniDOT    PME suggests you replace the batteries often  
22. sample interval will be displayed next to the Set Sample  Interval button  If this interval is acceptable the interval need not be set     Precision Measurement Engineering  Inc  15   760  727 0300  www pme com    To set the interval  enter a interval not less than 1 minute and not greater than 60  minutes  Click the Set Sample Interval button  Shorter and faster intervals are  available  Contact PME    End miniDOTControl by closing the window  Unplug miniDOT USB connection     Upon disconnection of the USB cable the miniDOT will begin logging or remain halted  as indicated by the position of the Logger Control Switch     2 3 miniDOTPlot    Begin program operation by clicking on miniDOTPlot jar  Software presents the  screen shown below              Plot Rev      x   AI fN E Fast Response Sensors and Systems  Surface Elevation  meters   0 00 B       Elevation    Barometric Pressure  Salinity  ppt   0 00    Select DATA Folder   none selected                miniDOTPlot plots the files recorded by the miniDOT Logger  The software reads all  miniDOT files in a folder  except the CAT txt file  The software will also compute  oxygen saturation from dissolved oxygen measurements  To do this software must  know the air pressure and salinity  It calculates air pressure based on elevation of  the water surface above sea level or uses the barometric pressure you enter if  Barometric Pressure is selected  If Elevation is entered  no compensation for  weather induced barometric pressure v
23. t of the end cap threads  If internal  pressure is suspected  then treat the miniDOT Logger with extreme caution     Revision History    2014NOV14 Added update Java instructions  Removed statement saying alkaline batteries  supplied     2015APR15 Added file upload to Android phone instructions          U    Precision Measurement Engineering  Inc    760  727 0300  www pme com    CONTENTS    Chapter 1 Quick Start    1 1 The Quickest Start Possible  1 2 A Few Details    Chapter 2 Software    2 1 Overview and Software Installation  2 2 miniDOTControl   2 3 miniDOTPlot   2 4 miniDOTConcatenate    Chapter 3 miniDOT Logger    3 1 Overview   3 2 Opening and Closing the Logger  3 3 Electrical Connections and Controls  3 4 Battery Replacement   3 7 Install Copper Mesh    Precision Measurement Engineering  Inc    760  727 0300  www pme com    Chapter 1  Quick Start  1 1 The Quickest Start Possible    Your miniDOT Logger has arrived completely ready to go  It is set to measure and  record time  battery voltage  temperature  oxygen concentration  and measurement  quality once every 10 minutes and write 1 file of measurements daily  You need only  open the miniDOT Logger and switch the Recording Control Switch to the RECORD  position  In this condition the miniDOT Logger will record measurements for a year  before the internal battery is expended  You must re close the miniDOT Logger prior  to deploying it     At the end of the deployment period you need only to open the logger and connect
24. tcl Product_Data_Sheet NA DATASHEETS MN1500_US_CT pdf       Caution  Improper replacement of the battery will damage the miniDOT Logger     Follow these steps     1  Move the Logger Control Switch to the Halt position    2  Remove the depleted batteries noting the position of the     terminal    3  Use only new  fully charged batteries  both of the same type    4  Install fresh batteries with the     position the same as the removed battery   The     position is also marked on the inside of the battery holder    5  The miniDOT Logger LED Light should flash to indicate that the software is    beginning operation within a second or two after you complete the battery  installation  At this time the logger will enter the mode selected by the Logger  Control Switch  which should initially be Halt from Step 1      If you install the batteries backwards you should plan to purchase a new  miniDOT Logger     End of Manual     Precision Measurement Engineering  Inc  21   760  727 0300  www pme com    
25. tly warm to the touch but not more than 30 deg C  These  organisms will deplete all the dissolved oxygen in the water  Cut a disc of thin plastic  film just large enough to lay on top of the water  Place this on top of the water  Do  not stir or bubble after placing the film  Record measurements for at least an hour or  more     Use miniDOT plot to examine the measurements  Saturation values should be very  close to 100   depending upon the accuracy that you have determined barometric  pressure  If you placed ice in the bucket then saturation values will still be 100  but  you will see the DO concentration and temperature change greatly as the bucket  warms     The recorded data when using yeast should show 0  saturation and 0 mg l dissolved  oxygen concentration  In practice miniDOT often reports slightly positive values of  about 0 1 mg l  but within the accuracy of the miniDOT     Closing and Opening     Close and open miniDOT like you would a flashlight  open  by unscrewing the white cylinder from the black end cap  Close by screwing the  white cylinder on  When closing  do not tighten the white cylinder  Just screw it on  until it makes contact with the black end cap  See Chapter 3 for more instructions     Caution  DO NOT remove the stainless steel screws in the black end cap  There are  no user serviceable parts here  If the screws are removed you will damage the  miniDOT and it will have to be returned for repair     Storage When Not in Use     Remove the batteries  K
    
Download Pdf Manuals
 
 
    