1. 1 The two LED indicators from the top stay green indicating the door is open in the mean time the other indicators reflect the authentication results 12_ system initialization amp basic operations TO REGISTER DELETE MASTER ID SSA S1000 1 First tum off the product and short circuit two lines purple line of Cable Alarm Out and blue line of the Door Contact Sensor Blue 2 When you turn the product back on you will hear the beep twice while Yellow all of the LED indicators tum red and repeat turning on off twice before being completely ON then the Master card will be deleted Sa Short Circuit 3 Upon deletion of the Master Card you will hear a beep once and White all of the LED indicators toggle between green and red twice pane before turning off in this condition they turn red from bottom up in sequence BOI Red 4 When the deletion is completed turn off the product Power Br Connect the purple line of Alarm Out and the blue line of the Door en Contact Sensor back to their original ports respectively 5 When you turn the product back on it recognizes and registers the first read card as the Master Card And if you present a registered user card to the product upon deletion of the Master Card that card will be registered as the Master Card NG f you present a registered user card after the Master Card is deleted that card will be registered as the Master Card TO REGISTE
2. cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help IMPORTANT SAFETY INSTRUCTIONS Read these instructions Keep these instructions Heed all warnings Follow all instructions Do not use this apparatus near water Clean only with dry cloth Do not block any ventilation openings Install in accordance with the manufacturer s instructions DN OD MS ONS Do not install near any heat sources such as radiators heat registers or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polarized or grounding type plug A polarized plug has two blades with one wider than the other A grounding type plug has two blades and a third grounding prong The wide blade or the third prong is provided for your safety If the provided plug does not fit into your outlet consult an ele
3. lock device green line of the Exit button and yellow line of the lock type White 2 When you turn the product back on all of the LED indicators Doy oak turn red or green repeat turning on off twice before being Exit Button completely turned off Green Yellow Lock Type E 3 In the power off condition all LED indicators turn green bottom up in sequence SAMSUNG 4 When you hear a beep 4 times that indicates that the initialization is completed Power A If you initialize the system all of the data settings will return to the factory default BASIC OPERATIONS When the power is supplied 1 All of the LED indicators will turn red or green and repeat turning ON OFF twice before being completely tumed OFF In the power off condition all LED indicators turn red bottom up in sequence 2 You will hear a beep once When you present a registered card to the product or press the Exit button 1 All LED indicators turn from red to green and tum off top down in sequence before turning back red 2 Then the door stays open for the specified time with the upper two indicators turning green which indicates the door is open 3 You will hear a beep once When you present an unregistered card to the product 1 All LED indicators turn red and repeat turning on off twice before staying in ON 2 You will hear a beep twice When you present a user card to the product while the door is open
4. should be used with a NO type button Check if the Exit button works normally Check the connection cable between the Exit button and SSA S1000 for any disconnection or short circuit Try to connect the two lines on the Exit button If SSA S1000 responds when you press the Exit button Replace the Exit button as it is defective If SSA S1000 does not respond at all Initialize the product as it is damaged or malfunctions nitializing the product will lose all user data If the trouble persists after following the procedures above contact a designated service center 14_ troubleshooting product specifications PRODUCT SPECIFICATIONS Item SSA S1000 Users 512 Users Power Current DC 12V Max 110mA Reading Time Card 30ms Door Open Time 5sec Fixed Input Port 3ea Exit Button Door Sensor Lock Type Select Power fail Safe Power Fail Secure Output Port 2ea TR Output DC 12V Rating Max 300mA Alarm Output DC 12V Rating Max 1A Lock Output LED Indicator 9 LED Indicators Red and Green Beeper Piezo Buzzer Operating Temperature 20 C to 50 C Operating Humidity 10 to 90 Relative Humidity Non Condensing Color Material Silver with Black Polycarbonate Dimension Wx H x Dimm 45 0 x 122 0 x 25 0 Weight 130g Correct Disposal of This Product Waste Electrical amp Electronic Equipment Applicable in t
5. R DELETE ID CARD 1 If you present the Master Card to the product it will sound the beep once and the first three LED indicators from the top will turn green from the top N MASTER CARD 2 If you present a new user card to the product it will sound the beep once and all of the LED indicators except for the first three ones from the top will tum from red to green Then they all tum off and tum 3 back on bottom up in sequence When all of the LED indicators tum back on they will turn red except for the first three LED indicators Paang from the top Then the user card will be registered 3 If you present a registered user card the product will sound the beep twice and all LED indicators except for the first 3 from the top will tum red and repeat turning on off twice before being completely ON Then the user card will be deleted 4 When you present the Master Card to the product after the user card is deleted the product will sound the beep once and all of the LED indicators tum red starting with the first three LED indicators from the top turning from green to red NG f you present a registered user card after the Master Card is deleted that card will be registered as the Master Card English 13 SNOILVH3dO IISVA 3 NOILVZITVILINI WALSAS troubleshooting TROUBLESHOOTING If the product does not function properly please see the below for trouble shooting SOLUTION PROBLEM The user car
6. SSA S1000 standalone RAD Access Controller user manual imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please visit our website www samsungsecurity com safety information RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONNEL This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit important operating and maintenance servicing instructions in the literature This exclamation point symbol is intended to alert the user to the presence of accompanying the appliance WARNING e To reduce the risk of fire or electric shock do not expose this appliance to rain or moisture WARNING 1 Be sure to use only the standard adapter that is specified in the specification sheet Using any other adapter could cause fire electrical shock or damage to the product 2 Incorrectly connecting the power supply or replacing battery may cause explosion fire electric shock or damage to he product Do not connect multiple controllers to a single adapter Exceeding the capacity may cause abnormal heat generation or fire Securely plug the power cord into the power receptacle Insecure connection may cause fire When installing the controller fasten it secur
7. ctrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 11 Only use attachments accessories specified by the manufacturer 12 Use only with cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus 1 ev Unplug this apparatus when a card is used Use caution when moving the cart apparatus combination to avoid injury from tip over 1 gt Refer all servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as powersupply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped English 3 NOILVINYOSNI AL34VS Contents PRODUCT INTRODUCTION INSTALLATION AND EXTERNAL CONNECTION SYSTEM INITIALIZATION amp BASIC OPERATIONS TROUBLESHOOTING PRODUCT SPECIFICATIONS 4 contents oo 0 ND O o 14 15 Feature What s included At a Glance Cable Color Scheme Cable Selection Installation Bypass Diode Connection 1 0 Connection Initializing the system by short circuiting Basic Operations To register delete Master ID To register delete ID card TroubleShooting Product Specifications product Introd
8. d is not deleted 1 Check if the product works properly If the product works properly and you have the Master Card Read the Master Card Read the card to delete Read the Master Card again to switch to normal mode For more information about deleting user cards refer to the ID registration and deletion section in this manual If you lost the Master Card Tum off the product and short circuit the purple and blue lines then turn the product back on The Master ID will be deleted with a flashing LED indicator and beep When the Master card is deleted tum off the product and restore the purple and blue lines to their respective original positions The very first card read by the product after tuming on the product will be registered as the Master Card For deleting the ID once the Master Card is registered refer to the ID registration and deletion section in this manual Tum off the product and short circuit the purple and blue lines then turn the product back on The Master ID will be deleted with a flashing LED indicator and beep When the Master card is deleted turn off the product and restore the purple and blue lines to their respective original The very first card read by the product after tuming on the product will be registered as the Master Card The Exit button does not work at all 3 Check if the Exit button is connected to SSA S1000 properly the Exit button
9. e outlet when there is a lighting storm Neglecting to do so may cause fire or damage 0 the product 5 Keep out of direct sunlight and heat radiation sources It may cause fire 6 Install it in a place with good ventilation 7 Avoid aiming the controller directly towards extremely bright objects such as sun 2_ safety information 8 Apparatus shall not be exposed to dripping or splashing and no objects filled with liquids such as vases shall be placed on the apparatus 9 The Mains plug is used as a disconnect device and shall stay readily operable at any time FCC Statement Caution Any changes or modifications in construction of this device which are not expressiy approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions any
10. ely and firmly The fall of controller may cause personal injury aap Do not place conductive objects e g screwdrivers coins metal parts etc or containers filled with water on top of the controller Doing so may cause personal injury due to fire electric shock or falling objects N Do not install the unit in humid dusty or sooty locations Doing so may cause fire or electric shock 8 If any unusual smells or smoke come from the unit stop using the product In such case immediately disconnect the power source and contact the service center Continued use in such a condition may cause fire or electric shock 9 If this product fails to operate normally contact the nearest service center Never disassemble or modify this product in any way SAMSUNG is not liable for problems caused by unauthorized modifications or attempted repair 10 When cleaning do not spray water directly onto parts of the product Doing so may cause fire or electric shock CAUTION 1 Do not drop objects on the product or apply strong blows to it Keep away from a location subject to excessive vibration or magnetic interference 2 Do not install in a location subject to high temperature over 50 C low temperature below 20 C or high humidity Doing so may cause fire or electric shock 3 If you want to relocate the already installed product be sure to turn off the power and then move or reinstall it 4 Remove the power plug from th
11. f batteries are not properly disposed of these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse please separate batteries from other types of waste and recycle them through your local free battery return system English 15 SALES NETWORK SAMSUNG TECHWIN CO LTD Samsungtechwin R amp D Center 701 Sampyeong dong Bundang gu Seongnam si Gyeonggi do Korea 463 400 TEL 82 70 7147 8740 60 FAX 82 31 8018 3745 SAMSUNG TECHWIN AMERICA Inc SAMSUNG TECHWIN EUROPE LTD 1480 Charles Willard St Carson CA 90746 UNITED STATES Samsung House 1000 Hillswood Drive Hillswood Business Tol Free 1 877 213 1222 FAX 1 310 632 2195 Park Chertsey Surrey UNITED KINGDOM KT16 OPS www samsungcctvusa com TEL 44 1932 45 5300 FAX 44 1932 45 5325 www samsungsecurity com www samsungtechwin com P No Z8100239401A
12. he European Union and other European countries with separate collection systems This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate these items from other types of waste and recycle them responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for BEN details of where and how they can take these items for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product and its electronic accessories should not be mixed with other commercial wastes for disposal Correct disposal of batteries in this product Applicable in the European Union and other European countries with separate battery return systems This marking on the battery manual or packaging indicates that the batteries in this product should not be disposed of with other household waste at the end of their working life Where marked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium or lead above the reference levels in EC Directive 2006 66 I
13. ng red and green indicators 2 Fixing Hole Fixing hole for wall mounting 8 Connection Cable Used to connect to the power or I O cable 4 Program Port Port used to upgrade the firmware 5 Buzzer Piezo buzzer English _ 7 NOILONGOHINI LONGOYd product Introduction CABLE COLOR SCHEME Item Cable Color Signal Line Description Red DC 12V 12V supplied Power Black GND Earth Grounding for Power Yellow AUX INPUT 1 Select a Lock Type Input Blue Door Contact Sensor Door Sensor Connection Port Green Exit Button Exit Button Connection Port Purple Alarm Out Alarm Device Connection Port Output White Door Lock Out Door Lock device connection port Gray Not used Orange Brown CABLE SELECTION Item Cable Type 1 Power DC 12V Belden 9409 18 AWG 2 Conductor Unshielded Door Contact Sensor Belden 9512 22 AWG 4 Conductor Shielded 2 Exit Button Sensor Input Belden 9514 22 AWG 8 Conductor Shielded ay Door Lock 3 3 Belden 9409 18AWG 2 Conductor Unshielded Alarm Device 8_ product introduction Installation and extemal connection INSTALLATION 10 dm 1 6 32 hole la r I Ka 6 32 or M3 Screws 3 1 3 a O 3 yA a 1 8 mo 1 1 2 hole o o o i O 6 32 hole a o 1 g I Reader gt 1 Module 1 I SAMSUNG wono I 8 5 On a doorframe or
14. t 1 Connect the DC 12V to the red line 2 Connect GND to the black line To connect the Door Contact Sensor 1 Connect the COM port of the sensor to the blue line 2 Connect the NO port of the sensor with the GND line To connect the Exit Button 1 Connect one end of the button to the green line 2 Connect the other end of the button to GND 10_ installation and external connection Output Connection DOOR LOCK OUT Door Lock white ALARM OUT purple Alarm Device SAMSUNG Cathode Anode Lock Type Select yellow Sn A 1N4004 1N4007 or equiv DC 12V GND DC 12V POWER To connect the power supply unit 1 Connect the DC 12V to the red line 2 Connect GND to the black line To connect the door lock device 1 Connect the plus line of the lock device to DC 12V 2 Connect the minus line of the lock device to the white line To connect the alarm device 1 Connect the plus line of the alarm device to DC 12V 2 Connect the minus line of the alarm device to the purple line To specify the lock type POWER FAIL SAFE Connect the yellow line to GND POWER FAIL SECURE Leave the yellow line in the floating state English 11 NOILLOANNOO TYNHILXA ANY NOLLVTIVLSNI system initialization amp basic operations INITIALIZING THE SYSTEM BY SHORT CIRCUITING 1 Tum off the product and short circuit three lines white line of Short Circuit the door
15. the wall 1 Drill a 1 2 inch 12 7 mm hole onto the center of the doorframe or the wall where SSA S1000 is installed which makes room for the cable of the reader module 2 Drill two 0 3 inch 7 62 mm holes one on the point of 0 39 inch 10 mm horizontally to the right 1 74 inch 44 4 mm vertically up from the center hole and one on the point of 0 33 inch 8 5 mm horizontally to the left 0 3 inch 7 62 mm vertically down from the point 3 Insert the reader module cable into the center hole and secure the module using two screws inserted in the upper right and the bottom left comer respectively 4 Insert the bezel of SSA S1000 into the reader module and attach it by pressing the upper and lower corner of he bezel BYPASS DIODE CONNECTION If you connected an inductor door lock or alarm device to the output relay there should occur a voltage surge while the inductor was between turning on and turning off If you do not connect a reverse diode to the relay the voltage surge will cause damage to the electric circuit of the controller To reduce this surge it is recommended to comnect the bypass diode to the relay English 9 NOILOANNOO TVNH31X3 ANY NOLLVTIVLSNI Installation and extemal connection O CONNECTION Input Connection DOOR CONTACT blue EXIT BUTTON Exit Button O green PUSH SAMSUNG ean DC 12V GND O black DC 412V DC 12V POWER To connect the power supply uni
16. uction FEATURE This product is designed for use with one door access control for security applications With its compact design you can install this product on the wall or a doorframe Its epoxy molding guarantees stable operation in a challenging environment This product enables you to control the door using the user card and provides a simple method to register or delete cards and initialize the system which is one of the most convenient and safest door controller And it is also featured by the 2 color LED indicator and the internal buzzer enabling you to easily check the current mode and operation of the door lock 125 kHz Proximity Access Controller Up to 512 users including one Master ID can be registered Standalone no application S W required Direct Control of the Door Lock Can select a lock device type from Power Fail Safe and Power Fail Secure Epoxy Molding Weatherproof English 5 NOILONGOHINI 1INGOYd product Introduction WHAT S INCLUDED Check if the following items are included in the product package 000000000 Main Module Bezel 3 5 x 40mm Screws x2 3 5 x 25mm Screws x2 aki 6 x 30mm Plastic Anchors x2 WECO DELE CD Manual 6_ product introduction Master Card 9 Master Card x1 Keytag x5 Quick Guide Quick Guide O AT A GLANCE Front Rear 1 LED Displays the system operation status usi