1. 1 2 3 4 5 6 7 8 Front panel with perforated air distribution surface Unit case Spring clips Inflow grid Air pre filter Power on button Red LED indicates abnormal operation of the unit Green LED indicates normal operation of the unit Label contains the main data in accordance with the requirements of GOST R 50444 The Unit is packed in the manufacturer s shipping containers in accordance with GOST R 50444 The unit consists of the following functional assemblies an outer case wherein the Potok 150 M 01 ADU is installed a front panel with a perforated air distribution surface pre filter a fan and an automation unit The unit performs high efficiency air flow disinfection by inactivation of all types of microorganisms and viruses and further filtration of aerosols Air flow treatment in the unit is a two stage process The inactivation zone the first stage is an area where repeated depolarization of the microorganism cell membranes is carried out with electrostatic fields of a given orientation and intensity which results in disintegration of their structure The fine filtration zone the second stage is an area that captures fragments of microbial cells and aerosol particles contained in the air flow being treated OPERATIONAL CONSTRAINTS If the unit was stored or transported in the cold season allow it to warm up to room temperature for 2 hours before starting it Apply the power suppl
2. requirements for indoor air disinfection level the number of units can be increased To arrange a pure working area e g a surgical table the front panel with a perforated air distribution surface of the unit should face toward the object that is being treated The use of air cross flows from two or more units can improve the degree of purity in the working area To achieve the maximum aseptic effect it is recommended to carry out wet cleaning of the premises with the unit running In order to maintain the achieved level of air purity the unit must run continuously The unit has no constraints with regards to its use PREPARATION FOR USE Make sure the unit housing is fully unpacked and unwrapped and has no damage Make sure the pre filter is in place and visually inspect its condition The unit is recommended to be mounted at a height of no less than 50 cm from floor level so that the inflow grid and front panel with perforated air distribution surface is located at least 30 cm from the wall or any objects blocking the free passage of air The unit installation location shall ensure the best air circulation indoors The unit location shall provide an easy access to a power socket There are mounting holes M6 on the rear wall of the housing which are used for securing the unit on the wall bracket with attachment standard VESA MIS F 200x200 M6 and a load carrying capacity up to 30 kg DESCRIPTION OF CONTROLS A powe
3. 0 VA POGUCUIVILY tr ssancttveonreteeedhces niiae EEA 130 m3 h Effectiveness of inactivation of RG1 4 microorganisms in the air min 99 Time required for inactivation 0 ccececeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 0 5s Microorganism inactivation control MOde cseeeeeeeee ees automatic Particle filtration efficiency ceeeeeee eens eee eeeee es class H14 filters Chief dimensions WXDXH cccccsceeeesteeeeeneeeeees 590x424x392 mm Weight cc tcc deen el ieee max 13 kg Lifetime without replacement of structural elements at least 10 years No consumables need to be used during the unit service life In terms of potential risks arising from application the unit belongs to Class 1 according to GOST R 51609 According to the National Product Classification the unit was assigned OKP code 945120 Actual concentrations of harmful substances in the working zone air shall not exceed maximum permissible concentrations specified in GN 2 2 5 1313 03 The unit climatic version is UKHL4 2 according to GOST 15150 The vibration and noise characteristics of the unit are in line with the regulatory and technical documentation requirements The unit is suitable to be used in the electromagnetic environment as per GOST R 51318 11 GOST R 51317 GOST R 50648 The unit is suitable for use in any locations including residential homes and buildings that are directly connected to the electrical distribution network
4. Thank you for your choice The Potok 150 M 01 standalone air disinfection unit ADU Premier is designed for ensuring and maintaining the required air purity in medical facilities of various types including those specializing in curing tuberculosis infectious diseases as well as in kindergartens pharmaceutical and food companies in transport and places of a mass congestion of people etc This Operation Manual applies to the Potok 150 M 01 standalone air disinfection unit ADU Premier hereinafter the unit and contains instructions for its operation maintenance transportation and storage as well as information certifying the manufacturer s warranties and certificates of acceptance and packaging Prior to using the unit please read this Operation Manual carefully and keep it at hand for future reference in case of questions in the course of its operation Attention Warning signs used on the inside and outside of the unit and their explanation A Attention Refers to THE OPERATION DOCUMENTS B TYPE EQUIPMENT i HAZARDOUS VOLTAGE Geel al serrer a gecdestdatielendsabniaea acoassancaeaieeesaedameceaetans 2 Parts And ACCESSOSICS 0 ce ceceeee eee e eee nin tense ee ee ee eseeteeee nate 3 Technical data and parametefrs 2 2 0ceceeeeeeeeeees 4 Unit appearance ccec cee cec ee eeceee ee eee ee eeeeaeeeeaeereneeens 5 Labelin Ea evel daectidendd dealee evden 6 Package E aAA ahded
5. e power cord for integrity monitoring of the front panel indicators checking the unit location PRE FILTER The user shall regularly conduct visual pre filter inspection Periodic flushing and disinfection of the coarse mesh filter is necessary to ensure the unit normal operation Attention The unit operation with a clogged pre filter may negatively affect its performance To carry out maintenance on the pre filter remove the inflow grid Pull the grid upward completely by sinking in two spring pins and remove it by pulling it toward yourself Replace the clogged pre filter with the standby one which is included in the supply package Mount the grid in its initial position Wash the clogged pre filter with a disinfectant or detergent solution at a temperature of not higher than 60 C and dry it so it can be further used Attention In the event of damage to the pre filter you may buy additional filters through the manufacturer s customer service When using the unit inside premises with pathogenic microflora the coarse mesh filter shall be treated with a disinfectant in accordance with the existing regulations HOUSING FRONT PANEL INFLOW GRID Wipe the surfaces with a soft damp cloth moistened with disinfectant solution or pure water Do not use gasoline kerosene solvents or other chemicals or abrasives Remove any residual moisture with a dry cloth When using the unit inside premises with pathogenic microf
6. ent L S personal signature print full name year month date Potok 150 M 01 standalone air disinfection unit Premier Serial number Date sold Stamp here Notes on warranty slip date of receipt date of handover The warranty period shall be extended by the warranty repair period 11 MANUFACTURER S WARRANTIES The manufacturer guarantees the unit compliance with the technical specifications shall the customer follow the operation transportation and storage conditions and requirements specified in the Operation Manual The warranty repair as well as elimination of any failures caused due to the manufacturer s fault provided free of charge during the whole warranty period Warranty operation period of the unit from the date sold The unit is not subject to warranty repair in the following cases Absence of a warranty slip corrections in the warranty slip the unit serial number does not correspond to the number specified on the warranty slip damage or gluing traces of warranty labels Improper use of the unit visual mechanical damage chips cracks etc traces of chemically aggressive substances malfunctions caused by foreign objects liquids and concentrated vapors Natural disasters lightning fire flood etc and other causes that are beyond the reasonable control of the manufacturer and customer and that caused the unit damage Warranty
7. indeleds 6 Principles of operation ccecceeeeeeeeeceeeeeeeteeeeeeaes 6 Important safety information cccceeeeeeeeeeeeeeeeeeees 7 Maintenance 0cccececceeeeceeceee cence eee eeeeeeeeeeaeaeeeees 9 Storage and transportation cceceeeeeeeeeeeeeeeeeeeeeeenee ees 10 DISPOSAl araire cated aduaideae ay anadsdundeade reeds aE 10 Certificate oneei nosia en eet e vend sadaatamieenan aaa des 11 Warranty Certificate ccceeeeeeeeee eee eener eeeeeeteeaeeaeees 11 Special notes eonenn eceeceeeeeeeeeeeeeeeeeseeeeeeeeeeeeeeaeeeeaes 11 Warranty repair application request seeeeeeeeeeeeeees 13 Warranty repair Slip cccceeeeeeeeeeeeeeeeee ce eeeeeeeeeeeeeeeea 13 Potok 150 M 01 standalone air disinfection unit Premier Serial number Date of manufacture Manufacturer Potok Inter LLC Address 115162 Moscow Khavskaya str 18 bldg 2 tel fax 7 499 678 2099 e mail post potok com Web site www potok com The supply package shall be in line with the following table Product a Air disinfection unit l A Potok 150 M 01 ADU standalone Premier Spare pre filter 1 Operation Manual 1 Package 1 Additional accessories wall mount bracket set of pre filters POWEP SUpply seinninn aaa aaie aai 220 VAC 50 Hz Power CONSUMTION 0 00 eee cece cece ec eeeee ee eeeeeeeeaeeaeaeas max 1
8. lora its surfaces shall be treated with a disinfectant in accordance with the existing regulations Always check the unit location in accordance with the recommendations set forth in Section PREPARATION FOR USE The unit shall be stored in heated and ventilated premises where the following conditions are maintained ambient air temperature from 5 C to 50 C relative air humidity max 80 at a temperature of 25 C no vapors of chemically active corrosive substances The unit shall be transported by any types of transport packaged in the following conditions ambient air temperature from 50 C to 50 C relative air humidity max 80 at a temperature of 25 C The unit shall be safely secured in the shipping containers The unit shall be stored in an upright position inside the package which helps preserve the unit s integrity Stacking in a maximum of four rows is allowed When transported or stacked the unit must be in an upright position The unit is subject to disposal upon completion of its service life No special disposal requirements are specified 10 Potok 150 M 01 standalone air disinfection unit Premier Serial number Date of manufacture manufactured tested and packaged in accordance with the requirements of technical specifications 9451 001 17481392 94 TU and _ design documentation KD 9451 001 00 000 and accepted as fit for use Head of Quality Control Departm
9. r switch button is located in the middle of the unit side wall on the inflow grid side The following LEDs are located in the middle on the right part of the front panel green LED indicates normal operation of the unit red LED indicates abnormal operation of the unit ENABLING DISABLING Connect the power cord to a grounded power supply socket 220 22 V 50 Hz Attention Make sure the plug is securely plugged in Set the power switch in the ON position After switching on the unit you will hear the sound of a running fan and the green LED on the front panel will become lit Short term illumination of the red LED is possible Attention If the red LED is continuously lit contact the manufacturer s customer service POTENTIAL FAULTS When turning on the unit you do not hear the fan running and the green LED on the front panel is not lit please double check the following the power cord is connected to the socket the power cord is not faulty the power supply voltage is on Information about the unit s operation is displayed on the front panel in the form of lit red LED In the event of any failure contact the manufacturer s customer service Attention Before carrying out any maintenance make sure the unit is disconnected from the power supply During maintenance perform the following operations visual inspection of pre filter clog visual inspection of the unit for damage visual inspection of th
10. repair of the faulty unit shall be performed by the manufacturer Potok Inter LLC Address 115162 Moscow Khavskaya str 18 bldg 2 Tel fax 7 499 678 2099 e mail post potok inter ru In case of the unit failure during the warranty period the customer is advised to take one of the following actions in order to perform unit maintenance call the manufacturer fill out an application for warranty repair and send it to the manufacturer s address fill out an application for warranty repair and deliver the unit together with the warranty slip to the manufacturer 12 to be filled out by customer Potok 150 M 01 standalone air disinfection unit Premier Serial number Date sold Customer name contact phone address Brief description of failure to be filled out at the manufacturer s location during repair Potok 150 M 01 standalone air disinfection unit Premier Serial number Date sold Customer Troubleshooting operations completed Customer s signature Foreman s signature Date accepted Date of repair for repair completion 13
11. y voltage in accordance with the technical parameters A different voltage may damage the unit Do not connect the unit to a faulty socket Do not use adapters and extension cords wherever possible If used make sure that these comply with the applicable standards Never cut nor pinch the power cord avoid twisting and overtension Such actions may cause damage to it The power cord or plug damage may cause electric shock hazard In case of a long term shutdown disconnect it from the power supply Do not place containers with liquid onto the unit Avoid letting any objects or your fingers getting trapped in the inlet grating of the unit It is not recommended to operate the unit without the inflow grid and pre filter being installed Operation of the unit with a coarse mesh filter not installed will reduce its service life Never obstruct the inflow grid and front panel with the perforated air distribution surface of the unit never move the unit to the wall with the inflow grid facing it Do not place heaters near or under the unit Do not stand nor sit on the unit housing take necessary actions to avoid damaging it Do not open the unit by yourself This may result in damage to the unit and warranty to be revoked RECOMMENDATIONS FOR USE The required number of units in premises with a normal bacterial load level is recommended to be determined on the basis of one unit per 50 60 m In case of more strict