1. RED Fast Blink Overload or Short circuit Output Off RED Slow Blink Over or Low input voltage Output Off ORANGE Fast Blink Over temperature Output Off RED Inverter Fault Output Off OFF Power Off Output Off E Alarms Alarms Status Buzzer Sounds Overload or Short circuit Output Off Over or Low input voltage Output Off Over temperature Output Off Inverter Fault Output Off 6 Functions Protections Output Short Circuit Protection The inverter switches off the output immediately when the connecting load is short Then it recovers the output automatically after delaying 5 seconds for the first time 10 seconds for the second time and 15 seconds for the third time If the short circuit status still remains when the inverter tries to recover for 3 times you should clear the load faults then restart the inverter manually Overload Protection When the load power is 1 25 1 5 times 1 5 2 times and 2 times more than the rated value the inverter will switch off the output after working for 60 seconds 10 seconds and 1 5 seconds respectively Once the load power is over 230 of rating the inverter recognizes it as AC short circuit and auto switches off the output If the overload status still remains when the inverter tries to recover for 3 times you should reduce the loads then restart the inverter manually Input Low Voltage Protection The output is switched off when the input v
2. EPTELH User s Manual Before using the inverter you need to read and save the safety instructions STI 300 12 220 Power Frequency Pure Sine Wave Inverter The information presented in this document does not form part of any quotation or contract is believed to be accurate and reliable and may be changed without notice TABLE OF CONTENTS Introduction di 1 2 Mechanical DraWINgS coccccccnononononacnnonononos 2 3 Important Safety Instructions mn 3 4 Inverter Operation ccccoooconcncnononanononnnnanannnnos 5 SE i COCO oo er E E 6 Os PUNCIONS ya rar 9 7 Troubleshooting ccccnoooooonoccnononccnnnnnnnnano nono 12 A A 13 9 Technical Specification envi 14 1 Introduction Thanks for purchasing our company s inverter of STI series The product is a sine wave power frequency inverter which can convert 24V DC to 220V AC 50Hz based on full digital and intelligent design It features high reliability high efficiency concise outline small volume full protection functions easy installation and operation The inverter can be applied in many fields especially for solar photovoltaic power system Complete isolation type inverter technology noiseless sine AC voltage of output Adoption of advanced SPWM technology pure sine wave output Dynamic current loop control technology to ensure inverter reliable operation Saving mode for selection Wide DC input voltage range Excellent EMC desi
3. gn Low output harmonic distortion THD lt 3 LED indicators for input voltage range load power range normal output amp failure state Input polarities conversed load short circuit overload under over input voltage and over temperature protections and alarms inverter s inner fault protections Fitted for many kinds of AC loads such as household appliances electric tools and industrial devices Wide working temperature range industrial level 2 Mechanical Drawings Units mm GBPS FLIET SER oe N 8001 E G KIE G 89 00 e lb ES 0 l 142 6 154 166 3 Important Safety Instructions As an AC power supply equipment the inverter s output voltage is with the same level as that of household power plug Mind the AC output terminals or you may get an electric shock Attentions Connect the DC input according strictly to the requirement The power inverter has a relatively wide input range but too high or too low input may cause problems even destroy the inverter Do not expose the inverter to humid flammable explosive or dust environment Do not install the inverter in airproof location and keep enough space around the inverter Inverter input is recommended to connect to battery If for testing purpose user should select DC power supply current at least twice greater than that of the inver
4. le service 9 Technical Specification DC Input Input Rated Voltage 12V Input Voltage Range 10 5 16VDC No Load Power lt SW AC Output Output Voltage AC 220V 3 Rated Power P240W Maximum Short Time Power 450VA 10s Surge Power 600VA 1 5s Output Mode Single phase Output Waveform Sine wave Frequency 50 0 5 Hz Output Waveform Distortion THD lt 3 Efficiency at Rated Power gt 81 Mechanical Parameters Exterior L W H mm 314 5x166x 100 8 Installation L W mm 200x154 Hole Size mm R4 Net weight kg 5 3 Environmental Parameters Working Temperature 20 C 50 C Storage Temperature 35 C 70 C Humidity lt 95 N C i lt 5000 m Derating to operate according to Altitude l A IEC62040 at a height exceeding 1000 m Others Insulation Resistance Between DC input terminals and metal case 2550MQ Between AC output terminals and metal case gt 550MN Dielectric Strength Between DC input terminals and metal case Test voltage AC1500V 1 minute Between AC output terminals and metal case Test voltage AC1500V 1 minute Version No V1 0 BEIJING EPSOLAR TECHNOLOGY CO LTD Tel 86 10 82894112 82894962 Fax 86 10 82894882 E mail info epsolarpv com Website http www epsolarpv com
5. oltage is lower than 10 5 V and the output is auto switched on when the input voltage recovers to 13 V User can also manually restart the inverter to switch on output by the ON OFF switch when the input voltage recovers to 10 5 V Input Over Voltage Protection The output is switched off when the input voltage is higher than 16 V also the output is auto switched on when the input voltage drops to 15 V Fault Protection The inverter will shut down when the output voltage is error or when the inverter has inner fault Over Temperature Protection The inverter will shut down when the ambient temperature exceeds the normal level And it will be back to work when the temperature recovers to the normal level Others Saving Mode Inverter will perform the saving function if the saving mode switch is transferred to saving side It means that inverter shuts down the output provided the loads value is less than 20VA It cycles as below the output restarts after delaying 20 seconds and the inverter decides to remain output when the load is more than 20VA or to shut down output again when the load is less than 20VA It is recommended to disable the saving function if your loads is less than 20VA 7 Troubleshooting WARNING High voltage is inside the inverter do not open or disassemble it Attempting to service the unit yourself may cause the risk of electrical shock or fire Problem Pos
6. ontraries or it will damage the power inverter O Switch the inverter to ON and then turn the loads on one by one Check the operation state of both power inverter and loads Green of the LED indicator means the state is normal O If there are different loads it is suggested that turn on the load with large startup current first such as television then turn on the load such as lamp when the inverter works stable e If the failure LED indicator is Red and the buzzer alarms or no output when you turn on devices switch off the loads and power inverter immediately Check the system by referring to the troubleshooting guide Turn on the devices again according to the operation methods after the failure is removed 5 Panels DC Input Terminal Negative DC Input Terminal Positive E DC Input Panel Protective Grounding Ventilatio Load Level Indicator ES II NI Saving Mode Switch E Input Level Display Input Voltages LED Status Input Voltage RED Slow Blink lt 10 5V RED 10 5 11 V ORANGE 11 12 V GREEN 12 14 5V ORANGE Fast Blink 14 5 16V RED Fast Blink gt 16V E Load Level Display AC Loads LED Status AC Load ORANGE lt 60 VA GREEN 60VA 225 VA RED gt 225 VA RED Slow Blink Overload RED Fast Blink Short Circuit E Output amp Fault Status LED Status Status GREEN Output Ok
7. sible Cause Solution Input LED blink fault red LED slow blink Input voltage is too high or too low Measure the input voltage The inverter recovers when the input becomes normal Load LED Overload or load Check out if the AC load is blink fault red short within the rated power or LED fast blink whether there is load short Fault orange Over temperature Improve the quality of LED fast blink inside the inverter ventilation and do not block the vents Restart the inverter when it is cool down Faultred LED Inverter Remove all the connected abnormal plugs then restart If inverter works well please check the load and line If the LED keeps red the inverter has should be returned to the factory inside faults and 8 Maintenance You must do regular proper maintenance on inverter You should clean the cover regularly with a cloth to prevent accumulation of dust and dirt tighten the screws on the DC input terminals The warranty period of this product is one year from the date of original purchase This limited warranty is void if the unit is abused modified installed improperly or had its housing removed The manufacture is not liable for damages arising from the use misuse or operation of this product During the warranty period defective units will be repaired or replaced with the same or a comparable model Please properly keep the maintenance card for after sa
8. ter rated input to keep inverter normal operation Make sure the air ventilation clearance around the inverter is more than 10cm for when the inverter works continuously its surface may became very hot Keep away from the material or device which may suffer from high temperature when the inverter is working Connect the load devices to the AC output outlet or terminals then the DC input Make sure both the input and output connects are correct switch on the inverter first and then turn on the load Do not connect the battery charger or similar devices to the input terminal of the inverter Do not put the inverter close to the open lead acid battery because the sparkle in the terminals may ignite the hydrogen released by the battery e Do not attempt to repair the fault inverter yourself otherwise it may lead to a serious accident Please connect the manufacture s engineer 4 Inverter Operation Connect the input and output terminals accurately by referring to the previous chapter Use the ON OFF switch on the front panel to turn the power on Turn AC loads on one by one after the output of the inverter is normal in order to prevent protections resulted from the surge power O Set the power switch to the OFF position O Insert the load s plug into the inverter s output outlet or cables to the output terminals O Connect the battery terminal with red line with black line Do not connect them by c
Download Pdf Manuals
Related Search
Related Contents
NODS-490BS - コイズミファニテック m3-CIC/IIC mode d`emploi 9 514 0226 003 User Manual Distribution Plan Phase X- 3NG DOHUK Medical Equipment HK1800 HK1810 OM, McCulloch, Titanium HT555, Gladiator550, 953900589 平成 24 年度 外部精度管理調査結果 Le calcul des prix de revient et la fixation des prix 営農速報 Copyright © All rights reserved.