Use and maintenance manual
Contents
1. N B The address Ad 1 can in any case be used by any device connectable to the TeleNET in place of PLUS 100 PAN temperature display except for TWMT modules to which a different address must be assigned so as to avoid any conflict P d Rev 02 15 USE AND MAINTENANCE MANUAL Pag 25 CHAPTER 7 TROUBLESHOOTING 7 1 ALARMS DESCRIPTION AND PROCEDURES In the event of any anomalies the PLUS 100 PAN system warns the operator by displaying alarm codes and sounding the warning buzzer inside the control panel If an alarm is tripped the display will show one of the following messages ALARM CODE POSSIBLE CAUSE PROCEDURE TO BE FOLLOWED Temperature sensor not working e Check the temperature sensor properly stops the system e f the problem persists contact the technical assistance service Humidity sensor not working properly stops humidity control e Check the humidity sensor e f the problem persists contact the technical assistance service e Check the evaporator sensor e f the problem persists contact the technical assistance service Evaporator sensor not working properly defrostings scheduled EEPROM ALARM Switch off unit and switch back on EEPROM memory error detected e If the problem persists change the control all outputs deactivated board e Contact the technical assistance service to have the battery replaced Flat battery Compressor safeguard e g overheat or excess pressure Check compressor
2. 2 Release the and 7 keys 3 Select the variable to be modified using the or 7 key 4 When the variable has been selected it is possible Display the setting in the respective sector of the display 5 or 17 page 11 To modify the setting by pressing the SET key E and the or 7 keys When configuration values have been set you can exit the menu by pressing the and 7 keys simultaneously for a few seconds until the room temperature reappears alternatively do not press any key for a few seconds 5 The new settings are saved automatically when you exit the configuration menu ec 5 Rev 02 15 USE AND MAINTENANCE MANUAL Pag 13 PLUS 100 PAN CHAP 5 Parameter programming 5 7 LIST OF LEVEL 1 VARIABLES User level RANGE DEFAULT Temperature difference compared to main SET POINT L Differential for Humidification compared to 3 o main SET POINT ira Differential for Dehumidification compared to I r main SET POINT Tas Air changeover interval parameter only active 00 24 during the leavening phases hours Air changeover duration parameter only 1 60 min nin active during the leavening phases Defrosting interval interval between one defrosting and the next d4 0 no defrosting parameter only active Semis NBU during cooling and maintenance stages Max defrost duration time LABEL ss MEANING si End of defrosting temperature SET POINT Defrosting is not executed if the
3. MANUFACTURER Dorwy PEGO S r l Via Piacentina 6 b 45030 Occhiobello RO Italy e 10 Tel 439 0425 762906 Fax 39 0425 762905 DENOMINAZIONE DEL PRODOTTO NAME OF THE PRODUCT MOD PLUS 100 PAN IL PRODOTTO E CONFORME ALLE SEGUENTI DIRETTIVE CE THE PRODUCT IS IN CONFORMITY WITH THE REQUIREMENTS OF THE FOLLOWING EUROPEAN DIRECTIVES Direttiva Bassa Tensione LVD 2006 95 CE Low voltage directive LVD EC 2006 95 Direttiva EMC 2004 108 CE Electromagnetic compatibility EMC EC 2004 108 LA CONFORMITA PRESCRITTA DALLA DIRETTIVA E GARANTITA DALL ADEMPIMENTO A TUTTI GLI EFFETTI DELLE SEGUENTI NORME comprese tutte le modifiche THE CONFORMITY WITH THE REQUIREMENTS OF THIS DIRECTIVE IS TESTIFIED BY COMPLETE ADHERENCE TO THE FOLLOWING STANDARDS including all amendments Norme armonizzate EN 60730 1 EN 60730 2 9 EN 61000 6 1 EN 61000 6 3 European standards EN 60730 1 EN 60730 2 9 EN 61000 6 1 EN 61000 6 3 IL PRODOTTO E COSTITUITO PER ESSERE INCORPORATO IN UNA MACCHINA O PER ESSERE ASSEMBLATO CON ALTRI MACCHINARI PER COSTITUIRE UNA MACCHINA CONSIDERATE DALLA DIRETTIVA 2006 42 CE Direttiva Macchine THE PRODUCT HAS BEEN MANUFACTURED TO BE INCLUDED IN A MACHINE OR TO BE ASSEMBLED TOGHETER WITH OTHER MACHINERY TO COMPLETE A MACHINE ACCORDING TO DIRECTIVE EC 2006 42 Machinery Directive Paolo Pegorari r P Pedo Rev 02 15 USE AND MAINTENANCE MANUAL Pag 29 PLUS 100 PAN Appendices PLUS100
4. and dehumidification are not activated during air changeover CLOCK CALENDAR 6 5 Current time and date can be adjusted via the dMY and HMS parameters The current time is shown on the LCD display Pedo Rev 02 15 USE AND MAINTENANCE MANUAL Pag 19 PLUS 100 PAN MANUAL CYCLES 6 6 The controller recognises the manual cycles only hot or only cold from the temperature setting only when in stop mode not in stand by If the set point is less than or equal to 10 C the controller recognises the manual cold cycle It will consequently run the fans simultaneously with the compressor call and execute the programmed defrosts as per the parameter settings humidity control will not be executed If the set point is higher than 10 C the controller recognises the manual hot cycle Consequently the fans are run continuously humidity is controlled according to the RH setting and the defrost cycles are not executed Pag 20 MUSS s ANG E NENNT m CHAP 6 Using the unit PLUS 100 PAN 6 7 AUTOMATIC CYCLES It is possible to set four automatic pause leavening cycles each with fully independent automatic programmed leavening and a maintenance only cycle riC O with cooling start The four cycles have the following characteristics cycle n 1 is carried out the same day 12 hrs cycle n 2 is for the next day 24 hrs cycle 3 for the second successive day 48 hrs and cycle 4 for the third successive day after the 72 hrs To
5. at any time note however during the active cycle manual heat cool cycles included via key 6 that during a complete cycle variation of the set point is relative to the phase in progress The first phase is known as cooling cold is produced and accumulated If the recipe has a cooling time of 0 00 the controller immediately goes to the maintenance phase at the start if the cycle There then follow maintenance intermediate leavening final leavening and where enabled settling N B the end of the cycle Li4 product ready time is defined by the end of the final leavening phase not the settling cycle PLUS 100 PAN The cooling phase is characterised by e Temperature set point e Duration of the phase The maintenance phase is characterised by e Temperature set point e Humidity set point The leavening phase is characterised by e Temperature set point e Humidity set point e Duration of the intermediate leavening phases via 2 level parameters and overall leavening duration programmed by final user N B overall leavening duration can never be less than the sum of the 5 parameter programmed steps The settling phase is characterised by Duration in hours 2 level parameter e Temperature set point pin level parameter e Humidity set point 2 level parameter If a phase has time 0 it is not executed and the controller goes to the next phase Phase times continue even in the event of an ele
6. by the buzzer sounds and the EP message appears on the display to USE AND MAINTENANCE MANUAL map PLUS 100 PAN indicate erroneous programming To switch off the buzzer press key 7 ve The progress of the cycle is highlighted at the top of the unit as follows Phase 1 cooling n 5 segments Phase 2 maintenance n 5 segments Phase 3 leavening n 6 segments Phase 4 settling where enabled n 4 segments If a settling phase is enabled sector 19 will light up at the cycle START to remind the user that when the product ready time is reached the cycle will be completed by a settling phase It goes off at the start of the settling phase i e when segment n 17 lights up While a complete cycle is being carried out the number of the recipe riC 01 can be viewed on the RH display and the baking day time displayed alternately on the clock display 17 for a few seconds by pressing key 3 briefly While a complete cycle is in progress you can view and modify the recipe in use by pressing key 4 for 2 seconds you can vary temperature and humidity but not the duration times of the different stages At the end of the final leavening cycle if settling is not enabled the controller goes to stand by The buzzer sounds and the segment bar flashes to indicate that the cycle is over Buzzing flashing stops automatically after 1 minute or when key 7 is pressed The user can vary temperature and humidity set points alternately
7. enter the recipes programming mode press key 4 until the letters riC appear on A the temperature display and the numbers 01 04 on the RH display Use keys 4 and 7 to select the recipe to be programmed press key 3 to enter programming mode for the selected recipe The 20 segments at the top of the unit should all be off only one of the first four will remain on to remind you of the recipe you are programming To program the data proceed as follows 1 Use the or 7 key to select the variable to be modified After selecting the desired variable it will be possible to 2 View the value on the respective sector of the display 5 or 17 page 11 3 Modify the setting by pressing or maintaining the SET key J and pressing the or Y key Exit programming mode from the product ready day window LI6 by keeping key 4 pressed for 2 seconds in any case the unit will exit programming mode if no keys are touched for 30 seconds COO Rev 02 15 USE AND MAINTENANCE MANUAL Pag 21 PLUS 100 PAN CHAP 6 Using the unit CYCLE PROGRAMMING DATA DISPLAY Default Default TEMP DISPLAY RH DISPLAY TIME recipe 1 recipe 2 Cooling temperature E _ ACT 20 0 C ii 1 Cooling time nn AN AC2 Off 00 00 00 29 59 00 04 00 00 05 00 00 Maintenance Co1 temperature Off 2 4 5 C 15 C Hr Maintenance Co2 50 99 0 o i us Final leavening Li1 temp Off 27 30 1
8. of conformity Page 30 A 2 PLUS 100 PAN connections diagram P d Rev 02 15 USE AND MAINTENANCE MANUAL Pag 3 PLUS 100 PAN CHAP 1 Introduction CHAPTER 1 INTRODUCTION 1 1 GENERAL The PLUS 100 PAN system allows the user to control temperature and humidity The system consists of the 100 MASTER unit on which all the electrical connections are made and the PLUS 100 PAN control panel which features a large LCD display to provide rapidly available complete information on room status The system allows the user to cool heat and ventilate the room switch the room light on off humidify it effect an air changeover dehumidify it defrost it and control alarms 12 PRODUCT ID CODES PLUS100 PAN control of temperature and humidity for pause leavening applications Pag 4 USE AND MAINTENANCE MANUAL Rev 02 15 P go Z CHAP 1 Introduction PLUS 100 PAN OVERALL DIMENSIONS 1 3 100N MASTER PAN PLUS100 PAN 121 50 e H 98 X180 IDENTIFICATION DATA 1 4 The unit described in this manual has on its side an ID plate showing all the relevant identification data Name of Manufacturer QM Code and model of electrical board Pat n 24 ng COCHIOBELLO ROWIGO e Serial number M P protection rating Power supply voltage I II CC P d Rev 02 15 USE AND MAINTENANCE MANUAL Pag 5 PLUS 100 PAN CHAP 2 Installati
9. status e Check compressor absorption e f the problem persists contact the technical assistance service Compressor and dehumidification output deactivated if parameter dEU Oor 1 e Check connections between the two units No connection between control Check for presence of ferrite on sensors panel and control board f the problem persists contact the technical assistance service Erroneous recipe programming e Check recipe duration with product ready goes to stand by time and day at the moment of cycle START au e Check for correct match between Software compatibility error MASTER board and control panel board Pag 26 USE AND MAINTENANCE MANUAL Rev 02 15 Pedo CHAP 7 Troubleshooting PLUS 100 PAN e Check specific alarm type on humidifier Fan overheat safety device f EURO os mis e f the problem persists contact the technical relevant output not deactivated ssistance service Humidifier alarm relevant output deactivate The Control Panel does not respond and the display is blank The Control Panel does not respond and the display reads En The PLUS 100 PAN system generates false alarms The humidity sensor does not display the correct humidity value The PLUS 100 PAN system does not respond to the parameters set on the configuration TROUBLESHOOTING GUIDE PROBABLE CAUSE Power supply fault check connection lead to control board Control board power supply n
10. you can exit the menu by pressing the and 7 keys simultaneously and keeping them pressed until the room temperature value reappears Exit from Level 2 is not automatic even if keys are left untouched for a long time 5 Changes are saved automatically when you exit the configuration menu 6 To enable the electronic controller press the STAND BY ke ESI IAO Rev 02 15 USE AND MAINTENANCE MANUAL Pag 15 PLUS 100 PAN CHAP 5 Parameter programming 5 9 LIST OF LEVEL 2 VARIABLES Installer level 0 NO Minimum time between BETTE compressor shutdown and 0 15 min 0 min subsequent switching on Network address for connection to the TeleNET system Dehumidification mode select 0 2 cooling Separate dehumidification calls 1 heating heat cold by temperature only 2 separated dehumid 1 enabled 02 disabled Humidification enable Humidification control only executed during leavening and settling phases 1 enabled 02 disabled Dehumidification enable Humidification control only executed during leavening and settling phases Ambient sensor value correction 10 410 C 0 Humidity sensor value conection 20 20 rH 0 rH First leavening step temperature set point 0 45 C 5 First leavening step humidity set se nin E 85 rH Eon controlled First leavening step duration I Second leavening step temperature set point Puedo o 10 C Second leavening step humidity meos p B
11. 0 C 45 C Leavening duration pes me EU O t14124t34t4415 09 59 00 94 00 00 05 00 00 Final leavening H3 Rue 50 99 9 OM n 99 Product ready time nn an Li4 Off 00 00 23 59 00 02 00 00 02 30 00 p End of cycle settling ale 1 Yes O No ot 2 2 Product ready day Li6 Off 01 01 04 31 12 99 read only N B the 00 cycle is dedicated to a cool only cycle that consists of an initial cooling phase followed by a switch to maintenance for an indefinite period the programmable data items for this recipe are therefore AC1 AC2 Co1 Co2 Once programming has been completed you can start a cycle by pressing key 3 for a few seconds The display asks which recipe is to be used riC 00 riC 04 Select the desired recipe via the up down keys when key 3 is pressed again the product ready oven ready time and day are displayed for 5 seconds If the shown data is correct there is no need to carry out any further tasks and the controller makes subsequent checks and then starts the cycle If however the data is incorrect stop the cycle by pressing key 3 ES enter the recipe modify the incorrect data and restart the cycle The controller makes a quick calculation to see if the cycle duration time is compatible with the product ready time and day If everything is compatible the cycle begins and the first segment lights up If instead there are incompatibilities the controller goes to stand
12. PAN CONNECTIONS DIAGRAM v JOON maser Power section Outputs section free voltage contacts 1 2 Power supply 230VAC 50 60 Hz 21 22 Alarm 23 24 Defrost Analogic inputs section 25 26 Dehumidification air changeover 29 30 Evaporator sensor NTC 15 16 Stand by 31 32 Humidity sensor 4 20 mA 0 13 14 Humidification 100Rh 32 V 31 Y 27 28 Ambient sensor NTC 11 12 Room light 9 10 Evaporator fans low speed Digital inputs section 7 8 Evaporator fans high speed 44 50 Fan overheat safety device 5 6 Heat 43 50 Humidifier alarm 3 4 Cold 42 50 Switch door 41 50 Compressor safety device TeleNET section 39 A line on 2TWRS485 40 B line on 2TWRS485 High speed terminals 7 8 close terminals 9 10 open Low speed terminals 7 8 open terminals 9 10 close Pag 30 USE AND MAINTENANCE MANUAL Rev 02 15 Pego PLUS 100 PAN NOTES USE AND MAINTENANCE MANUAL Rev 02 15 Dealer
13. PLUS 100 PAN CONTROL SYSTEM FOR DOUGH RETARDES Use and maintenance manual READ AND KEEP Electrical Boards 5 ZCO REV 02 15 ELECTRICAL BOARDS FOR REFRIGERATING INSTALLATIONS Jm ENG PLUS 100 PAN o LLAES INTRODUCTION CHAP 1 Page 4 1 1 General Page 4 1 2 Product ID codes Page 5 1 3 Overall dimensions Page 5 1 4 Identification data INSTALLATION Page 6 2 1 Important information for installer CHAP 2 Page 6 2 2 Standard assembly and use kit FUNCTIONS CHAP 3 Page 7 3 1 Functions managed by the PLUS 100 PAN TECHNICAL CHARACTERISTICS ras Techical charactors Page 9 4 2 Warranty terms PARAMETER PROGRAMMING Page 10 5 1 Control panel CHAP 5 Page 11 5 2 LCD display Page 12 5 3 General features Page 12 5 4 Key to symbols Page 12 5 5 Setting and displaying the set points Page 13 5 6 Level 1 programming Page 14 5 7 List of Level 1 variables Page 15 5 8 Level 2 programming Page 16 5 9 List of Level 2 variables USING THE UNIT Page 18 6 1 Cold hot maintaining room temperature CHAP 6 Page 18 6 2 Humidifying dehumidifying maintaining room humidity Page 19 6 3 Ventilation Page 19 6 4 Air changeover Page 19 6 5 Clock calendar Page 20 6 6 Manual cycles Page 21 6 7 Automatic cycles Page 25 6 8 Supervision monitoring system TeleNET TROUBLESHOOTING Page 26 7 1 Alarms description and procedures CHAP 7 Page 27 7 2 Troubleshooting guide APPENDICES Page 29 A 1 EC declaration
14. at 80 rH set point controlled Second leavening step duration i hemin 00 00 2 00 hh mm 00 30 Third leavening step temperature se set point 0 45 C 16 C Third leavening step humidity set mos pnus n t 80 rH pomt controlled Pag 16 MOZA NON ne Pego Pes c ZH Es a CHAP 5 Parameter programming PLUS 100 PAN s PAVONE REE CANON 00 00 2 00 hh mm 00 30 imm Fourth leavening step temperature set point MSc Fourth leavening step humidity d hone not 80 rH Ser pomi controlled s ven SIEP uuratoh 00 00 2 00 hh mm 00 00 imm Fifth leavening step temperature Fifth leavening step humidity set ms Nude os D controlled Fifth leavening step duration Hr 1 humidity control enabled Hr 0 humidity control disabled Humidity sensor Humidity control can be disconnected 1 without error the display shows evaporator sensor instead of humidity if Evaporator sensor exclusion PE ead 1 sensor absent Enabl li i Ene rane suonatcloweringand Drmiddebed ual 1 cold enabled settling Settling phase temperature set 0 445 C point Settling phase humidity set point 50 99 rH 0 defrosting disabled 1 defrosting enabled Defrost enable during cooling USE AND MAINTENANCE MANUAL Rev 02 15 PLUS 100 PAN CHAP 6 Using the unit CHAPTER 6 USING THE UNIT 6 1 COLD HEAT MAINTAINING AMBIENT TEMPERATURE Heating cooling i
15. ctrical power failure or controller stand by When an automatic cycle is in progress it is possible to check the number of the cycle in use and the in oven day time by briefly pressing key 3 CYCLE START sector 17 of the display DATE TIME shows first day and then time Pag 24 RUSEEANP RAINIER Ner SENE PLUS 100 PAN Supervision monitoring system TeleNET 6 8 The TeleNET supervision system allows the user to create a historical room temperature and humidity database via Personal Computer To configure the instrument refer to the TeleNET manual 100N MASTER TeleNET TYPICAL CONNECTION PICAL CONNECTION RS485 RS485 2TWRS485 Assign the PLUS 100 PAN system address via the configuration sequence by selecting the Ad label from the 2 programming level installer level and following the normal address attribution criteria used for TeleNET Temperature as detected by the controller can be displayed at the TeleNET address Ad 1 by setting the module as TWMT temperature acquisition module In this way the TeleNET supervision program can simultaneously display temperature and relative humidity as measured by the PLUS 100 PAN and build up a record of both parameters Example if parameter Ad is set to 3 relative humidity can be displayed on the TeleNET by assigning the TWMUR module to address 3 temperature can be displayed by assigning address 4 obtained by summing one to the parameter Ad 3 as the TWMT module
16. led to dehumidify heat is added only to maintain ambient temperature 2 Dehumidification with heating heat is called to dehumidify cold is added only to maintain ambient temperature If the difference in temperature is with respect to the setting greater than 5 C during dehumidification with the compressor and elements 5 C the unit with the Pag 18 RUSSES s Ner EVENT mem Peg CHAP 6 Using the unit PLUS 100 PAN greater value shuts down to prevent any overheating or over cooling which could damage the product 3 Separated dehumidification dehumidification output activated only but without cold heat call if the humidity set point is set to the minimum 5096 neither dehumidification nor humidification are controlled VENTILATION 6 3 Fan speed is regulated by two digital outputs high low speed and run at high speed with the cold call during the cooling and maintenance phases and continuously at low speed during the leavening and settling phases Fans are always off during defrosting Variants can be controlled via parameters F5 and F6 AIR CHANGEOVER 6 4 Air changeover is controlled via parameters d0 and d1 Use d0 to establish the interval between one air changeover and another the counter starts its count from zero at the start of every manual or automatic leavening cycle If d0 00 no air changeover is carried out Use d1 to establish the duration of the air changeover Cooling heating humidification
17. nd by light on continuously controller ON light flashing controller in STAND BY 17 Time date time parameter values 53 GENERAL To enhance safety and simplify the operator s work the PLUS 100 PAN system has two programming levels the first level Level 1 is used to configure the frequently modified SET POINT parameters The second programming level Level 2 is for general parameter programming of the various controller work modes It is not possible to access Level 2 programming directly from Level 1 you must exit the programming mode first 5 4 KEY TO SYMBOLS For purposes of practicality the following symbols are used the UP key is used to increase values and in programming the cycles e 7 the DOWN key is used to decrease values and mute the alarm 5 5 SETTING AND DISPLAYING THE SET POINTS 1 Press the SET key to display the current SET POINT temperature or humidity 2 Hold down the SET key and press the or keys to modify the SET POINT 3 Release the SET key to return to room temperature display the new setting will be saved automatically Pag 12 USE AND MAINTENANCE MANUAL Rev 02 15 CHAP 5 Parameter programming PLUS 100 PAN LEVEL 1 PROGRAMMING User level 56 To gain access to the Level 1 configuration menu proceed as follows 1 Press the and 7 keys simultaneously and keep them pressed for a few seconds until the first programming variable appears on the display
18. ogramming g Stand by system at standstill does not interrupt cycle in progress m SET temperature SET humidity press successively to alternate temperature and humidity 7 DOWN forced defrosting alarm mute o9 Room light Pag 10 MOZNA NON mcm Pego T CHAP 5 Parameter programming PLUS 100 PAN 5 2 LCD DISPLAY 1 2 3 4 5 CE LEi rau E e E E a a BB p 7888 TIME PRG 6 Wk 4 ox 8 O 7 8 9 10 11 12 13 14 15 16 17 1 Progress of PHASE 1 cooling duration set by final user physically occupies sectors n 1 2 3 4 5 2 Progress of PHASE 2 maintenance so called elastic phase physically occupies sectors n 6 7 8 9 10 3 Progress of PHASE 3 leavening duration set by final user physically occupies sectors n 11 12 13 14 15 16 Progress of PHASE 4 product ready settling max duration 4 hours occupies the last sectors n 17 18 19 20 Relative ambient humidity parameter values error codes Ambient temperature parameter values Programming controller is in programming mode Cooling flashes if called for dehumidification only 5 6 7 8 9 Heating flashes if called for dehumidification only ec oJ Rev 02 15 USE AND MAINTENANCE MANUAL Pag 11 PLUS 100 PAN CHAP 5 Parameter programming 10 Humidification 11 Dehumidification 12 Defrosting 13 Evaporator fans both high and low speed 14 Light 15 Alarm 16 Sta
19. on CHAPTER 2 INSTALLATION 2 4 IMPORTANT INFORMATION FOR THE INSTALLER 1 Install the device in places where the protection rating is observed and try not to damage the box when drilling holes for wire pipe seats 2 Do not use multi polar cables in which there are wires connected to inductive power loads or signalling wires e g probes sensors and digital inputs 3 Do not fit power supply wiring and signal wiring probes sensors and digital inputs in the same raceways or ducts 4 Minimise the length of connector wires so that wiring does not twist into a spiral shape as this could have negative effects on the electronics 5 Fit a general protection fuse upstream from the electronic controller 6 All wiring must be of a cross section suitable for relevant power levels 7T When it is necessary to make a probe sensor extension the wires must be of the correct cross section which in any case must be at least 1 mm 2 2 STANDARD ASSEMBLY AND USE KIT The PLUS 100 PAN system is supplied with the following assembly and utilisation items n 2 temperature sensors n 1 fixing bracket n 1 telephone plug lead n 1 user s manual Pag 6 USA NP s ANG SENE m Pego CHAPTER 3 FUNCTIONS 3 1 FUNCTIONS CONTROLLED BY THE PLUS 100 PAN Display and adjustment of temperature and humidity settings neutral zone Activation deactivation of stand by mode Sensor alarm warning signals Adjustment of differential temperatu
20. ot connected Incorrect connection between Control Panel and Control Board Panel power supply probably inverted with RS 485 signal Incorrect connection between Control Panel and Control Board Connection between Control Panel and Control Board interrupted Sensor s connected incorrectly or faulty Sensor is not connected properly Correct type of humidity sensor not selected Incorrect parameter settings PROCEDURE TO BE FOLLOWED Check that power arrives at the Panel and or Control Board terminals Check connections between Control Panel and Control Board If the problem persists contact the technical assistance service Invert RS 485 signal lead connection Check connections for continuity Check all connections Check Control Board connection leads for continuity If the problem persists contact the technical assistance service Check that sensor is working properly and that connection is correct Check the system configuration settings P d Rev 02 15 USE AND MAINTENANCE MANUAL Pag 27 PLUS 100 PAN CHAP 7 Troubleshooting e The PLUS 100 PAN I system does not Connection of PLUS 100 PAN system to Check the connection to the TeleNET network Check attributed address EE MS the TeleNET module network has not 9 been made correctly TeleNET USE AND MAINTENANCE MANUAL nap Appendices PLUS 100 PAN APPENDICES A 1 CE DECLARATION OF CONFORMITY COSTRUTTORE
21. re and humidity parameters Adjustment of air changeover control parameters Adjustment of defrosting parameters Adjustment of fan parameters Display of output status Simultaneous display of temperature and humidity values Automatic program management with automatic variation of temperature and humidity settings over time Clock function P d Rev 02 15 USE AND MAINTENANCE MANUAL Pag 7 PLUS 100 PAN CHAP 4 Technical characteristic CHAPTER 4 TECHNICAL CHARACTERISTICS TECHNICAL CHARACTERISTICS 4 1 Power supply Voltage 230 V 1096 50 Hz MAX power absorption 8 VA Climatic conditions Working temperature 10 60 C Storage temperature 30 70 C Relative humidity below 90 RH Input characteristics Analogical inputs NTC 10K 1 Temperature sensor 4 20 mA Humidity sensor Read resolution 1 C Temperature 1 RH Humidity Sensor read precision z105 O see characteristics of humidity sensor Read range 45 45 C 0 99 RH Output characteristics Qu onela 1 output on terminal N A 30A AC1 230 V AC ypt y 9 outputs on terminal N A 16A AC1 230 V AC Dimensional characteristics 100 MASTER box dimensions mm 121 5x 71 x 175 HxDxL PLUS PAN keypad box mm 98 x 35 x 180 HxDxL Insulation characteristics Keypad protection rating IP55 Pag 8 USE AND MAINTENANCE MANUAL CHAP 4 Technical characteristics PLUS 100 PAN 4 2 WARRANTY CONDITIONS PLUS 100 electronic con
22. s neutral zone controlled on the basis of the temperature set point key 6 and the temperature differential parameter d t Cooling is activated when the set differential threshold is passed and stays on until the set point is reached Heating is activated when the setting differential threshold is reached and stays on until the set point is reached E HUMIDIFICATION DEHUMID MAINTAINING AMBIENT HUMIDITY Humidity and dehumidification are neutral zone controlled during the leavening maintenance and settling phases only and only if the programmed set point is greater than the settable minimum 50 on the basis of the humidity set point key 6 the differential for Humidification parameter d U and differential for Dehumidification parameter d d Humidification is activated below the set differential for Humidification parameter d U threshold and stays on until the set point is reached Dehumidification is activated above the set differential for Dehumidification parameter d d threshold and stays on until the set point is reached Humidity control can be disabled via the Hr relative humidity parameter or by setting the set point to the minimum R H 50 humidity control disabled display only Dehumidification alone be disabled via the End parameter Humidification alone can be disabled via the EnU parameter There are three dehumidification modes dEU parameter 1 Dehumidification with cooling cold is cal
23. temperature read by the defrosting sensor is higher than the end of defrosting setting 12 C in the event of a faulty sensor defrosting is Fan stop time Expressed in minutes At the end of defrosting the fans can be kept at standstill for a further set time This time begins 0 10 min 2 min at the end of defrosting parameter active only in the cooling and maintenance phases Fan shutdown temperature Expressed in C At the end of defrosting or at start up the fans can be kept at standstill until the evaporator sensor temperature setting is reached parameter active only in the cooling and maintenance phases Defrosting sensor temperature display evaporator y DMy DMy Current date date ma s Pag 14 USE AND MAINTENANCE MANUAL Rev 02 15 Pegs a CHAP 5 Parameter programming PLUS 100 PAN LEVEL 2 PROGRAMMING Installer level 5 8 To access the second programming level press the UP and DOWN 7 keys and the LIGHT key simultaneously for a few seconds When the first programming variable appears the system automatically goes to stand by 1 Select the variable to be modified by pressing the UP and DOWN 7 keys When the parameter has been selected it is possible to 2 View the setting in the respective sector of the display 5 or 17 page 11 3 Modify the setting by holding the SET key down and pressing the or 7 key 4 When configuration settings have been completed
24. trollers are covered by a 24 month warranty against all manufacturing defects valid from date of delivery If the system malfunctions as a result of tampering impact or improper installation the warranty will automatically be rendered null and void It is strongly recommended that you observe all instructions information regarding the technical characteristics of the device WARNING Any modifications made to wiring and or internal components or any tasks carried out in a way that fails to comply with the information instructions in this manual shall not only render the warranty null and void immediately but may also lead to malfunctions irreparable damage serious injury or put persons objects in danger PEGO S r l declines any responsibility for possible errors or inaccuracies written in this manual as a result of printing or transcription errors ce PEGO S r l reserves the right to modify its products as it deems necessary without altering its main characteristics Each new release of a PEGO user manual replaces previous ones CQO Rev 02 15 USE AND MAINTENANCE MANUAL Pag 9 PLUS 100 PAN CHAP 5 Parameter programming CHAPTER 5 PARAMETER PROGRAMMING CONTROL PANEL P LCD display 2 Automatic cycle progress bar 3 Cycle START STOP hold for a few seconds to start or stop an automatic cycle Timer press once to show day and time of end of cycle in progress 4 UP Automatic cycle pr
Download Pdf Manuals
Related Search
Related Contents
zoom-zoom - Le Portail The Bureau of Meteorology Statistical Downscaling Model Graphical Typhoon DVB-T USB Drive Pompe autoadescanti per piscine con prefiltro incorporato Soehnle Slim Design Niro SMS Smart Media Solutions PL020050 flat panel wall mount Digitus DC-19102 keyboard video mouse (KVM) cable SEDGO sensual 2D 5L GOLDEN Copyright © All rights reserved.