AS-i Safety Output Relay with four standard inputs

image

Contents

1. ASI ASI 14 Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Product Description EUCHNER 4 5 Operating interface 1 pit HEN HEN RUN PRG 11 12 131 1 Switch to select the operational mode FAULT _ ALARM QOQO PRG Safety relevant AS i address can be programmed uat Qut Secure operation not possible RUN Secure operation possible non safety relevant AS i address can be AN programmed Addressing jack ADDR LEE ERCI E 171 24 ASI ASI NC 4 6 Indicators Indicators Display Meaning PWR off No supply power green 1 Hz flashing Operational power on safety relevant AS i address and or AS i AB address is 0 green on Supply power on Fault off AS i communication OK red on No data exchange with the AB slave Out off Output Relay switched off green 1 Hz flashing Error lock state waiting for start signal after transmission of start signal Output Relay switches on green 8 Hz flashing The device is in an un lockable error state The device resumes regular operation after the Monitor sent the sig nal error unlock green on Output Relay switched on Alarm off AS i output bit AO not set red on AS i output bit AO set
2. AS i Safety Output Relay with four standard inputs Installation Instructions 8 6 Montage ES Operating temperature 0 C 55 C Temperature rating for cable 60 75 C Use copper conductors only 1x0 5 1 5 mm 16AWG min 24 max 12 on mounting plate with 35 mm top hat rail 2 28 Subject to reasonable modifications due to technical advances Id No 103573 EUCHNER emere 0 8 Nm D5 6 mm PZ2 7 LB IN E Cm 2x 0 5 1 5 mm zm EI 2x 05 1 5 mm AWG 2x24 12 Issue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316
3. lais ein Error lock state waiting for start signal after transmission of start signal Out 1 put Relay switches on Blocage red marrage actif attend le signal Start apr s le 1 Hz signal Start le relais de sortie est commut Blocco riavviamento attivo aspetta il seg nale Start i rel di uscita vengono commutati dopo il segnale start Bloqueo de reini cio espera a se al de inicio despu s de la se al de inicio el rel de salida se conecta I Das Ger t ist im entriegelbaren Fehlerzustand Wenn der Monitor das Signal Fehler entriegelung sendet arbeitet das Ger t wieder normal The device is in an un lock 1 able error state The devices resumes regular operation after the Monitor sent the 8 Hz signal error unlock L appareil se trouve dans un tat d erreurs d verouillable Lor sque le moniteur envoie le signal d verouillage des erreurs l appareil fonctionne de nouveau normalement L apparecchio in stato di errore sbloccabile Quando il motore invia il segnale sblocco di errori l apparecchio funziona di nuovo normalmente El aparato est en estado de error desbloqueable Si el monitor env a la se al Desbloqueo de error el aparato vuelve a funcionar de forma normal slo Ausgangsrelais eingeschaltet Output Relay switched on relais de sortie est d clench rel di uscita commutato Rel de salida conectado e S ALARM rot O AS i Ausgangsbit A 0 nicht gesetzt
4. 11 12 13 1 Y1 off Corresponding input is not on yellow Switch set to PRG cyclic flashing yellow on Corresponding input is on Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 15 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs EU C H N ER Maintenance 5 1 A A 1 6 Subject Maintenance Controlling safe shutdowns The plant safety engineer is responsible for verifying that the AS i Safety Output Relay with four standard inputs works correctly as part of the safety system At least once a year it is necessary to verify the safe shutdown by initiating asso ciated safety related sensors or switchs Attention Press each safety related AS i slave and watch the reaction of the output circuits of the AS i Safety Monitor Attention Check the maximum activated time and the total operating time These values depend on the PFD value chosen for the total failure probability Please refer to the information in chap Safety relevant data After reaching the projected maximum operating time three six or twelve months the entire safety system must be checked for proper operation After reaching the projected total usage time 20 years the device must be checked by the manufacturer concerning its proper operation to r
5. AS i output bit O 0 is not set bit de sortie AS i red S 0 n est pas mis bit di uscita AS i U O non messo Bit de salida S 0 de AS i no rouge est puesto bed AS Ausgangsbit A 0 gesetzt AS i output bit O 0 is set bit de sortie AS i S 0 est 0 mis bit di uscita AS i U 0 messo Bit de salida S 0 de AS i est puesto 1 n gelb O Der entsprechende Eingang ist nicht geschaltet Corresponding input not switched on 12 yellow I l entr e correspondante n est pas d clench e l ingresso relativo non commutato I3 1 Y1 jaune la entrada correspondiente no est conmutada Hom ES o o Lauflicht running light feu fixe giallo continuo corriendo luz Schalter steht auf PRG Switch is set to PRG commutateur se trouve sur PRG commutatore si trova su PRG El interruptor est en PRG Der entsprechende Eingang ist geschaltet Corresponding input switched l entr e correspondante est d clench e l ingresso relativo amp commutato la entrada corre spondiente est conmutada 2t LED an on allum e on en CE LED blinkend flashing clignotante ampeggiante el destellar O LED aus off teinte fuori fuera Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 27 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316
6. Attention This symbol warns of a potential failure Non compliance may lead to interruptions of the device the connected peripheral systems or plant potentially leading to total mal functioning Warning This symbol warns of an imminent danger Non compliance may lead to personal inju ries that could be fatal or result in material damages and destruction 1 1 Abbreviations AS i AS interface actuator sensor interface AOPD Active opto electronic protective device CRC Cyclic redundancy check yo Input output EDM External device monitoring EMC Electromagnetic compliance ESD Electrostatic discharge PELV Protective extra low voltage PFD Probability of failure on demand PLC Programmable logic control Saw Safety at Work safety technic Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 7 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs General Remarks EU H N ER 2 1 2 2 HO 2 3 2 4 General Remarks Please read this chapter carefully before working with the documentation and the AS i Safety Output Relay with four standard inputs Product information This user manual is valid for the following EUCHNER GmbH Co KG devices AS i Safety Output Relay with four standard SOM 4E 0A C1 inputs Function of this manual This man
7. reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs E H N ER Declaration of Conformity Konformit tserkl rung Declaration of Conformity Sicherheitsmonitor SFM SMO GMO SOM Safety monitor SFM SMO GMO SOM Gem den Anforderungen der Niederspannungs In accordance with the low voltage directive 2006 95 EC richtlinie 2006 95 EG der Maschinenrichtlinie 98 37 EG the machinery directive 98 37 EC and the EMC directive und der EMV Richtlinie 2004 108 EG erkl ren wir hiermit 2004 108 CE we hereby declare that the beneath listed die Konformit t der nachfolgend aufgef hrten Produkte mit products conform to the following European standards folgenden europ ischen Normen a EN 60947 5 1 Niederspannung Schaltger te a EN 60947 5 1 Low voltage switchgear and Steuerger te und Schaltelemente controlgear Control circuit devices Elektromechanische Steuerger te and switching elements Electro mechanical control circuit devices b EN 954 1 Sicherheit von Maschinen b EN 954 1 S curit des machines Parties des Sicherheitsbezogene Teile von syst mes de commande relatives la Regeleinrichtungen Allgemeine s curit Partie 1 Principes Gestaltungsleits tze g n raux de conception c EN 60204 1 Sicherheit von Maschin
8. safety contactors con nected in series the connection between the safety contactors and the device must never be subjected to another potential as this could result in the inadvertent activation of the safety contactors Input 1 Y1 just like inputs 11 13 is a standard AS i input 1 8 Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Installation Instructions E U C H N E R 8 Installation Instructions 8 1 SOM 4E 0A C1 AS i Safety Relaisausgangsmodul AS i Safety Relay Output Module Module avec sorties relais de s curit AS i Modulo di uscita rel di sicurezza AS i M dulo de salida de rel AS i Safety Dokumentationen AS i Safety Relaisausgangsmodul mit konventionellen 4E ASIMON ME Konfigurationssoftware f r Windows Documentations AS i Safety Relais Output Module with 4 standard inputs ASIMON Configuration Software for Windows Documentations Module avec sorties relais de s curit AS i avec 4E standard Logiciel de configuration ASIMON pour Windows Documentazioni Modulo di uscite rel di sicurezza AS i con 4 ingressi standard Soft ware di configurazione ASIMON per Windows Documentaci n M dulo de salida de rel AS i Safety con 4E convencional Software de con
9. seguridad se puede programar ADDR ae Adressierbuchse addressing jack prise d adressage presa di indirizzamento socket de direccio namiento 11 12 13 Eing nge E1 E2 und E3 Inputs 11 12 and 13 entr es E1 E2 et E3 Il ingressi 11 I2 e 13 entrada E1 E2 y E3 1 13 1 14 Ausgangskontaktsatz 1 Output contact set 1 plots de contacts de sortie 1 set di contatti di uscita 1 Juego de con tacto de salida 1 1 23 1 24 Ausgangskontaktsatz 2 Output contact set 2 plots de contacts de sortie 2 set di contatti di uscita 2 Juego de con tacto de salida 2 l 1 Versorgungsspannung f r Eing nge voltage supply for inputs tension d alimentation pour les entr es tensione di ali mentazione per gli ingressi Tensi n de alimentaci n para entradas 1 Y1 EDM Eingang R ckf hrkreis EDM input of external device monitoring circuit EDM entr e circuit feedback EDM ingresso circuito feedback EDM entrada circuito de retorno ASI ASI Anschluss AS i Bus AS i connection raccordement bus AS i collegamento bus AS i conexi n circuito AS i 20 Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Installation Instructions E U H N E R 8 3 1 Co
10. 1 Safety category 4 EN 13849 1 2006 PLe Performance level PL e Cat4 Safety integrated level SIL 3 EC 61508 Usage time TM in years 20 EN 13849 1 2006 PLe Cat4 Maximum operating time in month 12 EC 61508 PFD 2 10 EC 61508 EN 62061 PFHp 3 3 10 EC 61508 EN 62061 Probability of a dangerous failure per hour Max system reaction time in milliseconds 50 EC 61508 1 The PFD and PFH D values stated here are related to the maximum operating time of 12 month and a maximum usage time of 20 years according to EN ISO 13849 1 The relay s maximum switch time including the occurrence of errors is 50 ms starting at the time the code sequence is present until the switch off of the relay Additionally the response time of the monitor and the inputs must be included Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 1 3 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Product Description E U H N E R 4 4 Electronic connection Terminal settings Description 11 12 13 Inputs 11 12 and 13 1 13 1 14 Output connection set 1 1 23 1 24 Output connection set 2 l I Supply voltage for inputs 1 Y1 EDM External Device Monitoring AS i AS i Connection to AS i bus L1L2L3 1 Y1 121 24 ASE NC
11. EUCHNER AS i Safety Output Relay with four standard inputs User Manual SUpports the requirements for AS i Safety up to SIL3 Subject to modifications without notice Generally this manual refers to products without mentioning existing patents utility models or trademarks The absence of any such references does not indicate that a product is patent free Euchner GmbH Co KG Kohlhammerstr 16 D 70771 Leinfelden Echterdingen AS i Safety Output Relay with four standard inputs Table of Contents E U H N E R Table of Contents 1 Symbol Catalog inner ad 7 1 1 Abbreviations 7 2 General Remarks 8 2 1 Product information 2 2 Function of this manual 2 3 Target group AAA 8 2 4 AS l specifikatlon 3 0 io ii aa 8 3 SAL CCY eT 3 1 Experienced staff 3 2 Application area of the device unsuusunsnnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 9 3 3 Correct USC m AE E E 9 3 4 Disposal eerie teen reete ct tens niente cnt 10 4 Product Description 2 5 sn 11 4 1 AS I Safety at Work 1 inedito 11 4 1 1 Special characteristics of the AS i Safety Output Relay 11 4 2 Technical Data nsusrsnssssesnsnnnnnnnnnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 12 4 3 Safety relevant data 2 0 i 13 4 4 Electronic connection urusuusennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn
12. TUP 14 2 AS I SAFETY DIAGNOSIS SLAVE ADDR TOOL 15A OK OK y q FLAGS AS i AdresSe 1 5 ACTUAL CONFIG E Y OK LPF 7 F 1 5 ASI MASTER IO ID 1D1 1D2 ESC OKo lt lt N Fa m 5 AS I CIRCUIT 1 AS I CIRCUIT 2 RUN The correct safety function ofthe device must be verified once installed within the pro tected machinery 24 Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Installation Instructions E U C H N E R 8 5 Programming of the non safety relevant AS i address RUN 1 safety relay 4 standard AS i safety output output relay inputs 1 EDM inputs with 4 standard inputs __ less esta Eee Le p p imeem Perry Biss ps a ene Safety address t AB Slave 1 Safety address AB Slave EE HE 128 EN UU PROFIBUS QUICK SETUP i AS I SAFETY PROFIBUS lau ck setup DJAGNO penosa X SLAVE ADR TOOL O 5 Subject to r
13. Warning Please read this chapter carefully before using the AS i Safety Output Relay in combi nation with other machine safeguarding components on protected machinery Experienced staff The AS i Safety Output Relay must only be installed operated and maintained by qualified staff Qualified is a person who has a suitable technical education has been instructed in operating the machinery and has been informed about the valid safety guidelines by the machinery operator has access to the user manual Application area of the device The SOM 4E 0A C1 is a decentralized output module that safely controls actua tors on the AS i Safety at Work SaW safety bus system In this set up a Safety Monitor or a Gateway with integrated Safety Monitor re spectively controls the SOM 4E 0A C1 A special characteristic of this module is its two different kinds of AS i addresses Safe AS i address SOM 4E 0A C1 listens to the communication on the safe address and Switches based on these data Non safety relevant AS i address The non safety relevant AS i address is used for diagnostic purposes and for switching under PLC control All SaW output modules with the same safe AS I address switch at the same time The SOM 4E 0A C1 is certified according to EN 62 061 SIL 3 and EN 13 849 performance level e Correct use The AS i Safety Output Relay must only be used as defined in chap Application area of the device The AS i Sa
14. address 6 Check slave s ID2 code by using the hand held addressing device or AS i Master The code should be the same as the ones digit of the address 7 Check slave s IO code by using the hand held addressing device or AS i Master The code should be 7 8 Ifthe settings in steps 3 to 7 were correct continue with step 9 Otherwise repeat starting with step 1 9 Setthe switch on the device to RUN Warning The correct safety function of the device must be verified once installed within the pro tected machinery Programming of the non safety relevant AS i address This address can be programmed by using the hand held addressing device or AS i Master when the switch is set to RUN Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 1 7 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Safety Requirements E U H N E R 7 Safety Requirements The device uses two redundant force guided relays The module recognizes if one of the relays does not switch for instance if the contacts are welded The contact sets 1 13 1 23 and 1 14 1 24 use the same relay they do not operate independently The contacts 1 13 1 23 1 14 1 24 are potential free A cross short check is not available Ifthe device is set up to control two independent
15. easonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Address Assignment E U H N E R 6 1 6 2 Address Assignment The device offers two different types of AS i addresses The safety relevant single AS i address is the target address for the device through which it receives the signal for the safe release of the output This ad dress is not used for communication the device only uses it to listen to ongoing communications This address can only be programmed if the switch is set to PRG The device uses the non safety relevant A B AS i address to communicate with the master in order to exchange diagnostics data I1 13 1 Y 1 and control sig nals Alarm LED This address can only be programmed if the switch is set to RUN Programming of the safety relevant AS i address 1 Set device switch to PRG 2 Setdesired address by using the hand held addressing device or AS i Mas ter 3 Check programmed address by using the hand held addressing device or AS i Master 4 Check slave s ID code by using the hand held addressing device or AS i Master The code should be set to F 5 Check slave s ID1 code by using the hand held addressing device or AS i Master Code should be the same as the tens digit of the
16. easonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 25 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Installation Instructions 8 5 1 Address assignment 1 41 SEARCHING SLAVE LT SN LCD CRX TEN SLAVE ADR TOOL OLD ADDRESS 2 NEW ADDRESS 0 PRG EUCHNER OK Qe QUICK SETUP AS I SAFETY SLAVE ADR TOOL DIAGNOSIS OLD ADDRESS 2 SLAVE ADDR TOOL NEW ADDRESS 6A PRG OK A mx SN lt SLAVE ADR TOOL SLAVE ADR TOOL CONNECT NEW SLAVE OLD ADDRESS 2 OLD ADDRESS NEW ADDRESS 6A NEW ADDRESS PRG IN Fl SLAVE ADR TOOL CONNECT NEW SLAVE Modul anschlie en Connect module Reliez OLD ADDRESS module Colleghi modulo Conecte modulo NEW ADDRESS 2xESC N 4 UNKNOWN SLAVE Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 26 Subject to reasonable modifications due to technical advances Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Installation Instructions EUCHNER 8 5 2 LEDs LEDs Colors Status Signal Description PWR gr n O keine Betrieb
17. en c EN 60204 1 Safety of machinery Electrical Elektrische Ausr stung von equipment of machines General Maschinen Allgemeine requirements Anforderungen d EN 61000 6 2 EMV Fachgrundnormen d EN 61000 6 2 EMC Generic standards Immunity St rfestigkeit Industriebereich for industrial environments e EN 61000 6 4 EMV Fachgrundnorm e EN 61000 6 4 EMC Generic standards Emission St raussendung industriebereich standard for industrial environments f EN 50295 Niederspannungsschaltger te f EN 50295 Low voltage switchgear and Steuerungs und Ger te Interface controlgear Controller and device Systeme Aktuator Sensor Interface interface systems Actuator Sensor AS i Interface AS i a EN 61000 6 3 EMV Fachgrundnormen 9 EN 61000 6 3 EMC Generic standards Emission St raussendung Wohnbereich standard for residential commercial Gesch fts und Gewerbebereiche and light industrial environments sowie Kleinbetriebe h EN ISO 13849 1 Sicherheitsbezogene Teile von h EN ISO 13849 1 Safety related parts of control systems Steuerungen Allgemeine General principles for design Gestaltungsleits tze i EN 61508 Funktionale Sicherheit sicherheits i EN 61508 Functional safety of electrical bezogenerelektrischer elektronischer electronic programmable electronic programmierbarer elektronischer safety related systems Systeme j EN 62061 Sicherheit von Maschinen j EN 62061 Safety of machinery Functiona
18. fety Output Relay must only be used on the sys tem at which it was installed in accordance with this manual by adept personnel Information If used in a way differing from this description or if the device has been changed in any way even during installation any warranty claims with respect to EUCHNER GmbH Co KG are invalid Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 9 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs EUCHNER 3 4 Disposal X Information Electronic waste is hazardous waste Please comply with all local ordinances when E disposing this product The device does not contain batteries that need to be removed before disposing it 1 0 Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG Tel 49 711 75 97 0 Fax 49 711 753316 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen AS i Safety Output Relay with four standard inputs Product Description E U H N E R 4 1 HO 4 1 1 Product Description This chapter is intended to inform the reader about the special characteristics of the AS i Safety Output Relay with four standard inputs It describes the design and the functionality of the devices Warning This chapter must be read befo
19. figuraci n ASIMON para Windows 8 2 Dimensions 114 mm 99 mm Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 19 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Installation Instructions E U H N E R 8 3 Front view and connections 1 I PRG WIN REN EN Nl sicherheitsrelevante AS i Adresse kann programmiert werden Kein Schutzbetrieb m glich Program ming of safety relevant AS i address enabled Protective mode disabled mode de protection non pos sibile Adresse AS i relative la s curit peut tre configur e modo di protezione non possibile run PRG Indirizzo AS i relativo alla sicurezza pu essere configurato la direcci n AS i relevante para la segu 11 12 131Y1 ridad se puede programar no es posible modo operativo de protecci n FAULT ALARM RUN pwr S um Schutzbetrieb m glich nicht sicherheitsgerichtete AS i Adresse kann programmiert werden Protective ADDR O mode enabled Programming of non safety relevant AS i address enabled mode de protection possi A ble Adresse AS i non relative la s curit peut tre configur e modo di protezione possibile Indirizzo EFA AS i non relativo alla sicurezza pu essere configurato Modo operativo de protecci n posible la direc ci n AS i no direccionada a la
20. i 30 Vpc Over voltage category 3 for operating voltage 300 Vac acc to VDE 0110 part 1 Voltage isolation 26kV Utilized standards EN 954 1 Cat 4 IEC 61 508 SIL 3 EN 13849 1 2006 PLe Cat 4 EN IEC 6 2061 SIL 3 DIN EN 60 529 Housing DIN rail mountable housing Ambient operating temperature 0 C 55 C Storage temperature 25 C 85 C Dimensions 114 22 5 99 length width height in mm Protection category according to Housing IP20 Device Colors Value Color Description State change LED Out 0 green Output on on 1 green flashing 2 yellow Error lock Auxiliary signal 2 1Hz 3 yellow flashing 4 red Output off off 5 red flashing Waiting for error unlock signal Auxiliary signal 1 8Hz 6 gray Internal error for instance fatal Only through turning power on all LEDs are error on the device flashing 7 green yellow Output released but not turned on Switched on by setting O1 off 12 Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Product Description E U H N E R 4 3 Safety relevant data Identification data Value Standard Safety category 4 EN 954
21. l Funktionale Sicherheit sicherheits safety of safety related electrical bezogener elektrischer elektronischer electronic and programmable und programmierbarer elektronischer electronic control systems Steuerungssysteme Die Produkte werden mit dem CE Zeichen The products will be marked with the CE mark gekennzeichnet Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 5 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Declaration of Conformity Produkt gt m Product H ui Sicherheitsmonitor Safety monitor Profibus Gateway mit Sicherheitsmonitor GMO Profibus Gateway with safety monitor Sicherheitsausgang Modul Safety Output module Leinfelden Juni 2008 EUCHNER Konformit t mit EN Normen Conform with European Standards a b cd efh j bd fghij b d f g h i j ipl Ing Michael Euchner Gesch ftsf hrer Managing Director 6 Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 Symbol Catalog AS i Safety Output Relay with four standard inputs EU C H N ER Bro Symbol Catalog Information This symbol indicates important information
22. nnecting a safety contactor a A A L1L2L3 1 Y1 ASI O Adressierung ist auch mit Handadressierger ten m glich II In addition a hand held addressing device can be used to program the address Il L adressage est possible Il galement avec un dispositif d adressage manuel Il L indirizzamento anche possi Note bile con un dispoitivo di programmazione manuale II El asignamiento de direcci n es tambien posible con el dispositivo de mano Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 21 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Installation Instructions E U C H N E R 8 4 Programming the safety relevant AS i address PRG 1 safety relay 4 standard AS i safety output output relay inputs 1 EDM inputs with 4 standard inputs lecce Nem EEE ooo E ha Madii sos esas Safety Address AB Slave AB Slave Safety Address 1 PRG PROFIBUS QUICK SETUP AS I SAFETY DIAGNO SE mm um mmm TsLAVE ADR TOOL E EE SS 22 Subject to reasonable modifications due to technical advances Id No 103573 I
23. nsnnnnnnnnnnnnnnnn 14 4 5 Operating interface 220uu44400000n00nnnnnnnnnnnnnnnnnnannnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnen 15 4 6 Indicado f 15 Maintenance 5 1 Controlling safe shutdowns esses eee enne nnne 16 6 Address Assignment esses 417 6 1 Programming of the safety relevant AS i address 17 6 2 Programming of the non safety relevant AS i address 17 Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 3 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Table of Contents E U H N E R 7 Safety Requirements eese nennen nnn 18 8 Installation Instructions eeeeeeese eese enne 19 8 1 SOM A4E DA C mE 19 8 2 Dimensions ann 19 8 3 Front view and connections 8 3 1 Connecting a safety contactor 8 4 Programming the safety relevant AS i address PRG 8 4 1 Address assignment 8 4 2 Checking safety relevant address 15 8 5 Programming of the non safety relevant AS i address RUN 25 8 5 1 Address assignment 8 5 2 LEDs 8 6 Montage nie Ire trece ice crt un cie co eese ciue niente hind 28 4 Subject to
24. re installation and operation of the device in conjunction with other safety components on protected machinery AS i Safety at Work AS i Safety at Work combines safe and non safe data on a bus system The clas sification AS i Safety at Work identifies the safe data transfer that enables the in tegration of safety procedures in an AS i network The components of AS i Safety at Work conform to EN 50295 and are compatible with all other AS i components Therefore existing AS i applications can easily be extended with safety relevant functions AS i Safety at Work always requires a Safety Monitor as a stand alone device or integrated into a Gateway that evaluates the safe signals on the bus and a safe AS Interface bus connection that enables the transfer of safe signals from safe ty relevant components AS i SaW input Additionally decentralized safe AS I SaW outputs can be added Controlled by the Safety Monitor these outputs can be used to safely switch off safe actuators Several Safety Monitors and safe input and output slaves can be used on an AS i system At the same time the Safety Monitors can be parameterized and thus be checked through AS i and the configuration software Information By utilizing AS i Safety at Work safety requirements up to category 4 according to EN 954 1 and additionally performance level e according to EN 13 849 as well as SIL 3 according to EN 62 061 can be satisfied In order to satisfy the
25. requirements of these safety categories all peripheral com ponents for instance the Safety Monitors all safe bus connections and all con nected sensors must satisfy these standards Special characteristics of the AS i Safety Output Relay Two redundant force guided relays Two parallel galvanically isolated contact sets 4 standard inputs External sensors supplied from AS i e Programming jack Operating mode selector switch Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 1 1 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Product Description EUCHNER 4 2 Technical Data Inputs 3 standard inputs 1 EDM Outputs 1 relay 3 A 24 V DC 13 or 3 A 230 V AC 15 respectively AS i profile S 7 A E 1D1 Code Shex default user changeable External device monitoring EDM Supplied from AS i about 24 V about 10 mA Displays 3 LEDs yellow I 1 2 1 3 Status input 11 12 13 1 LED yellow 1 Y1 Status EDM input 1 Y1 LED green PWR AS i power supply LED red FAULT AS i error LED LED yellow OUT See table for flashing LED pattern Device colors LED red ALARM PLC signals alarm Operational current 200 mA Supply power for sensors 90 mA Operational current AS
26. spannung No supply power pas de tension de fonctionnement nes green suna tensione di funzionamento No hay tensi n de servicio rte Mun 1 Betriebspannung vorhanden sicherheitsrelevante Adresse und oder AS i AB Adresse v rd amp ist O Supply power is on safety relevant address and or AS i AB address is 0 1 tensione de fonctionnement pr sente adresse relative la s curit et ou adresse AB 1 Hz AS i est de 0 tensione di funzionamento presente indirizzo relativo alla sicurezza e o indirizzo AB AS i 0 Hay tensi n de servicio la direcci n relevante para la segu ridad y o la direcci n AS i AB es 0 alo Betriebspannung vorhanden Supply power on tension de fonctionnement pr sente I tensione di funzionamento presente Hay tensi n de servicio a FAULT rot red O AS i Kommunikation OK AS i communication OK communication AS i OK comu rouge nicazione AS i OK Comunicaci n AS i OK n TA kein Datenaustausch mit dem AB Slave no data exchange with the AB slave pas O 7 d change de donn es avec l esclave AB nessuno scambio dati con lo slave AB no N hay intercambio de datos con el esclavo AB OUT gelb yel Ausgangsrelais ausgeschaltet Output relay switched off relais de sortie teint rel low di uscita spento Rel amp de salida desconectado 715 Wiederanlaufsperre wartet auf Startsignal nach Startsignal schalten die Ausgangsre amarillo 0
27. ssue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Installation Instructions E U H N E R 8 4 1 Address assignment LCD 1 41 Ko bec SEARCHING SLAVE EM SN SLAVE ADR TOOL Kon OLD ADDRESS 2 NEW ADDRESS 0 Loa SM PRG OK Q QUICK SETUP AS I SAFETY SLAVE ADR TOOL DIAGNOSIS OLD ADDRESS 2 SLAVE ADDR TOOL NEW ADDRESS 15 PRG OK N ll SA Gila AS I CIRCUIT 1 AS CIRCUIT 2 SLAVE ADR TOOL OLD ADDRESS 2 NEW ADDRESS 15 PRG okon gg zw SLAVE ADR TOOL CONNECT NEW SLAVE SLAVE ADR TOOL OLD ADDRESS CONNECT NEW SLAVE NEW ADDRESS OLD ADDRESS NEW ADDRESS bs p 1 18 Modul anschlie en Connect module Reliez module Colleghi modulo Conecte modulo UNKNOWN SLAVE Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG 23 Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 AS i Safety Output Relay with four standard inputs Installation Instructions E U H N E R 8 4 2 Checking safety relevant address 15 1 LCD OK o Y Y 2 CONFIGURATION OK SN SN ACTUAL CONFIG MES Poe Me 12 13 A 14 15 X OK QUICK SE
28. ual instructs for the safe assembly electrical installation addressing start up as well as for the operation and for the maintenance of AS i Safety Out put Relay This manual does not provide instructions for operating machines on which this module is built in Please view the appropriate machine manual for corresponding information Information Additional information concerning the technical data as well as the parameterization of the AS i Safety Output Relay can be found in data sheet SOM 4E 0A C1 that can be located at http www euchner de Target group This manual is intended for designers developers and operators of systems that will be safeguarded by one or more AS i Safety Output Relays The manual is also targeted to people integrating AS i Safety Output Relays into machinery per forming the initial start up or maintaining them AS i specifikation 3 0 The AS i Safety Output Relay with four standard inputs is designed according to the new AS i specification 3 0 Earlier specifications 2 1 and 2 0 continue to be fully supported 8 Subject to reasonable modifications due to technical advances Id No 103573 Issue date 28 5 2009 EUCHNER GmbH Co KG Kohlhammerstra e 16 D 70771 Leinfelden Echterdingen Tel 49 711 75 97 0 Fax 49 711 753316 Safety 3 1 3 2 3 3 O Il AS i Safety Output Relay with four standard inputs EU C H N ER Safety This chapter contains user safety information

Download Pdf Manuals

image

Related Search

Related Contents

RACING SPEED XLR  NOTEBOOK Guia de instalação  Rebuilt and Modified Altec 1567A: A Technical Report  Jøtul F 500  44-120型 44-125型 取扱説明書 給湯暖房用熱源機  Philips 3121 235 20061 CRT Television User Manual  INSTALLATION AND SETUP GUIDE  User's Manual - Altehandys.de  Digitus DB-272403 USB cable  Tecumseh AWG5524EXN Performance Data Sheet  