1. 900 Band lt listener gt If the external integration application has remained inactive for a long period of time a request to the producer asking for the entire list of active events is recommended using a True request This way the listener again has all the information lost during the period of inactivity 4 3 8 5 Reception of events When there is any change in the events the request that the producer creates against the listeners distribution list giving information about the events will be PUT type with the following syntax http ip_oyente port services user producer xml The request contains the following information in XML format in the body of the message information about the events produced lt producer gt lt all gt T F lt all gt lt event gt lt id gt driverld driverld driverld eventld lt id gt lt name gt Evento 1 lt name gt lt description gt Descripcion 1 lt description gt lt annotation gt Anotacion 1 lt annotation gt lt date Time gt 25112010201034 lt date Time gt lt whyFired gt ACTIVATION lt whyFired gt lt event gt lt event gt lt id gt driverld driverld driverld eventld lt id gt lt name gt Evento 2 lt name gt lt description gt Descripcion 2 lt description gt lt annotation gt Anotacion 2 lt annotation gt lt date Time gt 25112010201034 lt date Time gt lt disabledDate Time gt 25112010201 103 lt disabledDate Time gt Output Features Type LED symbol
2. Where dhcp_name is the name assigned and authenticated by the name server of the local area network LAN or a DNS server in case of using a DynDNS system to connect to the Internet Internal configuration web site and even the time and date data M98240601 03 13B m CIRCUTOR Wetwork setup Hest marme eciemadenrl DHC aon OOF DHCP Client ID Address Hetmriask Modem setup APN Liser Password Rezet timer hours Time setup Primar Y NTP Server pool ntp ang Secondary MTP server lime Zone Europe Madnd T irre martes OF de febrero de 2012 11 41 24 Dynamic ONS setup Server type Disabiad Hostname Liger Password Server Port Security setup Password Gn amp OFF User name Mew password Repeat password Information MAC W 0A 00 00 88 02 1 0 modem beta 4 3 2 BETA 2 3 4 Access via password If an access user name and password have been parameterised the device requests these access parameters when trying to access via the web site in the following pop up screen hegit 14 4 7 esti eokctance un nombre de usuario y une omt mele O sto dcx PowerSade 3 Operation EDS 3G is an energy efficiency manager with a Web server display from which the user can view the status of the device inputs and outputs in real time as well as any possible action to be taken As well as serving the data stored internally via the Web the device has an XML server enabling the user to send GET and
3. 2 3 APN Modem The configuration parameters associated with the modem s GPRS 8G connection must be entered in accordance with the configuration used by the operator in each case The SIM card must be inserted and a data tariff must be enabled for this application The unit must be disconnected from the auxiliary power supply to insert or remove the SIM card APN or Access Point Name is the GPRS access point name that must be configured on the mobile device to provide access to computer networks The SERGLL RIGHT key is used to enable the edit cursor on the first digit Press this key and the SCROLL DOUN and SCROLL UP buttons to establish the parameters of an alphanumeric data entry of up to 20 digits After the data is entered press the SCROLL RIGHT key twice until the edit key disappears and then validate the data with the SCROLL DOUN key by going to the next screen 2 2 4 User modem The USER will be supplied by the operator that supplies the SIM card The cursor is enabled with the SCROLL RIGHT key and the SCROLL UP and SCROLL GOWN buttons can be used to establish the parameters of an alphanumeric data entry Validate the data with the SCROLL DOWN key 2 2 5 Password modem The PASSWORD will be supplied by the operator that supplies the SIM card The cursor is enabled with the SCROLL RIGHT key and the SCROLL UP and SCROLL DOWN buttons can be used to establish the parameters of an alphanumeric data entry Validate the data
4. Dynamic Network Services can update information on domain names hosted in a name server in real time The most common use involves assigning an Internet domain name to a PC with a variable IP address EDS 3G with a dynamic IP in this case This allows the unit to be connected with no need to hire an Internet connection with fixed IP identification 2 2 11 1 1 DynDNS host Enter the DNS server name supplied by the dynamic DynDNS service provider The cursor is enabled with the SCROLL RIGHT key and the SCROLL UP and SCROLL DOWN buttons can be used to establish the parameters of an alphanumeric data entry Validate the data with the SCROLL DOUN key 2 2 11 1 2 DynDNS user Enter the user name USER of the dynamic DynDNS service supplied by the service provider The cursor is enabled with the SCROLL RIGHT key and the SCROLL UP and SCROLL DOWN buttons can be used to establish the parameters of an alphanumeric data entry Validate the data with the SCROLL DOUN key 2 2 11 1 3 DynDNS password Enter the password of the dynamic DynDNS service supplied by the service provider The cursor is enabled with the SCROLL RIGHT key and the SCROLL UP and SCROLL DOWN buttons can be used to establish the parameters of an alphanumeric data entry Validate the data with the SCROLL DOUN key M98240601 03 13B m CIRCUTOR 2 2 11 2 CirDNS System CIRONS is a proprietary system that has been designed to invert the role of the remot
5. and end FILE data not grouped returns the information as registered in the database if the period parameter does not appear in the request it is considered as value 0 and the data is not grouped http x x x x services user records xml begin 0103201 10000 00 end 31032011000000 var dispositivo variable period 9 00 http nombre_dhcp services user records xml begin 010320 11000000 end 31032011000000 var dispositivo variable p eriod 900 lt recordGroup gt lt period gt lt period gt lt record gt lt dateTime gt lt dateTime gt lt field gt lt id gt lt id gt lt value gt lt value gt lt field gt lt record gt lt recordGroup gt recordGroup field identifying the XML as a response to the variable record request period recording period time between recordings record identifies each recording dateTime date and time of the sample field standard recording value for others consult PS manual value value of variable at the time of the request 4 3 6 Historical events file As this user manual describes the PowerStudio Scada Editor makes it possible to configure events or alarms in the EDS 3G device and record them in the internal memory With the following request the user can request the historical events file between the dates defined Every event that is requested with a historical events file is defined as id name_event When only the
6. m CIRCUTOR EDS 3G ENERGY EFFICIENCY MANAGER EDS 3G Efficiency Data Server is an energy efficiency manager with a built in GPRS 3G modem The device has an RS 485 communications bus as well as 8 digital inputs and 6 digital outputs via relay which allow it to communicate with external field devices representing and storing the information via its Ethernet connection and integrated web server EDS 3G also has a standard XML server through which other external applications can integrate information from the device easily and intuitively This document represents the user and operation manual of the EDS 3G device If misplaced the manual may be downloaded from CIRCUTOR s web site www circutor com Disconnect the device from the power supply form of maintenance modification of connections repairs etc If you suspect any operational faults in the device or in its protection system remove the device from service The design of the device makes it easy to replace in the event of a fault source before undertaking any 1 Buttons The front panel of the EDS 3G device has an alphanumeric LCD display along with four function buttons allowing the user to navigate through the configuration screens of the device The buttons have two operating methods SHORT KEYSTROKE when the user presses the function button for less than two seconds LONG KEYSTRGKE when the user presses the function button for more than two second
7. or suspect any malfunction contact our service staff at CIRCUTOR SA CIRCUTOR SA Technical Assistance Service Vial Sant Jordi s n 08232 Viladecavalls Barcelona SPAIN Tel 902 449 459 Spain Tel 34 93 745 29 00 outside Spain e mail sat circutor es M98240601 03 13B
8. with the SCROLL DOUN key 2 2 6 PIN modem The Fi will be supplied by the operator that supplies the SIM card The cursor is enabled with the SCROLL RIGHT key and the SCROLL UP and SCROLL DOWN buttons can be used to establish the parameters of an alphanumeric data entry Validate the data with the SCROLL DOUN key EDS 3G Insert the PIN and the unit will display on the screen The value is visible and can be edited in configuration mode provided that the security option is not enabled Enable Security 2 2 Reset modem The unit has an automatic reset system that is activated when a fault or anomaly is detected in the mobile connection system but since the unit can be installed remotely in a place that is hard to access it also has a forced auto reset system for the GPRS 38G connection This RESET MODEM HOURS is expressed in hours which indicates that the device is automatically reset when the unit has been connected with a GPRS 3G_ connection with no interruptions during a determined number of hours The cursor is enabled with the SCROLL RIGHT key and the SCROLL UP and SCROLL DOWN buttons can be used to establish the parameters of an alphanumeric data entry Validate the data with the SCROLL DOUN key 2 2 8 Primary NTP The device can be synchronised with a time and date NTP server Network Time Protocol server in the UTC time system The device does not display a value by default indicating that the synchron
9. PUT type requests 3 1 Web Server Once the Ethernet addressing is configured and integrated into the Ethernet network the device variables are visible to the user via a conventional Internet Explorer browser with Java plug in installed on the computer http www java com es download Another access interface is the PowerStudio Scada Client To see the Web display interface the user must access it via the http address below http XXxX XXX XXX XXX http nombre_dhcp Where xxx xxx xxx xxx is the IP address assigned by the user Where dhcp_name is the name assigned and authenticated by the name server of the local area network LAN or a DNS server in case of using a DynDNS system to connect to the Internet 3 2 XML server The XML server is an excellent integration tool for external applications EDS 3G has a server available whose access requests are identified in this manual see 4 XML instructions 3 3 Digital inputs The device has a total of 8 digital inputs whose function is to count energy impulses coming from external sensors or for detection of the logical status of the input The contacts of the digital inputs of the device must be voltage free dry contacts 3 3 1 Impulse energy meter function Electronic meters have an impulse output that is proportional to the recorded power With its inputs EDS 3G is a centralising unit with 8 digital inputs opto coupled for reading impulses from electrici
10. be logged into the Ethernet network The SERGLL RIGHT key is used to enable the edit cursor on the first digit Press this key and the SCROLL UP and SCROLL DOUN buttons to establish the parameters of an alphanumeric data entry of up to 20 digits After the data is entered press the SCROLL RIGHT key twice until the edit key disappears and then validate the data with the SCROLL DOUN key by going to the next screen 2 2 2 2 Assigned values DHCP YES After entering the CLIENT ID name in the device for the first time the device displays the parameters assigned by the DHCP server on the screen The parameters that are being edited will not be fixed until the device is fully configured so that it will display the following fields on the screen which cannot be edited asterisk on the upper left hand corner 2 2 14 1 IP 2 2 14 2 Netmask At this point the DHCP server has not assigned the Ethernet addressing values yet displaying 000 000 000 000 Press the SCROLL GOWN a few times until you select the APN Modem option The 3G version of the unit does not offer the Gateway and Primary and Secondary DNS configuration option This is due to the fact that the unit is connected to the Internet via the GPRS 3G network and not via the local area network To this end the unit is connected to the Ethernet network and only available on the same local area network with no routing possibilities due to the lack of the gateway 2
11. ce variable http x x x x services user values xml var dispositivo variable 9 http nombre_dhcp services user values xml var dispositivo variable 4 3 4 2 Instantaneous value of all variables Request for instantaneous values of all the variables of the device if information is needed about more devices link the other requests below with id device http x x x x services user values xml id dispositivo http nombre_dhcp services user values xml id dispositivo lt values gt lt variable gt lt id gt lt id gt lt value gt lt value gt lt variable gt lt values gt id identifier of the variable value value of variable at the time of the request 4 3 5 Historical data Request for historical data log of an incremental variable Returns information on one or more variables between the begin and ena dates Each variable for which information is required must be included in the request as var device variable When only the date is required the format is DDMMYYYY When the date and time are required the format is DDMMYYYYHHMMSS Both the date and the time must be expressed in UTC Universal Coordinated Time The grouping period can be defined by different criteria value in seconds for example 900 value in seconds in which the data is grouped ALL the data is grouped into a single value AUTO grouping is automatic with predefined intervals according to begin
12. date is required the format is DDMMYYYY When the date and time are required the format is DDMMYYYYHHMMSS Both the date and the time must be expressed in UTC Universal Coordinated Time http x x x x services user events xml begin 0103201 100000 0 end 31032011000000 id nombre suceso http nombre_dhcp services user events xml begin 0103201 1000000 end 31032011000000 id nombre suceso lt main gt lt recordGroup gt lt id gt lt id gt lt record gt lt date gt lt date gt lt eventld gt lt eventid gt lt annotation gt lt annotation gt lt value gt lt value gt lt record gt lt recordGroup gt lt main gt main field identifying the XML as a request recordGroup field that groups all the recordings of an event id event identifier record identifies each record date event date and time eventid event identifier annotation event annotation value event value ON active event OFF inactive event ACK event acknowledged 4 3 7 Device events Returns the information about recorded events of one or more devices between the dates begin y end Each device for which information is required must be included as id device http x x x x services user recordsEve xml begin 010320110 00000 end 3103201 1000000 id dispositivo http nombre_dhcp services user recordsEve xml begin 010 32011000000 end 31032011000000 id dispositivo Cuando se desee in
13. dicar solamente la fecha el formato es DDMMAAAA cuando quiere especificarse la fecha y hora es EDS 3G DDMMAAAAHHMMSS Tanto la fecha como la hora debe estar expresado en UTC Universal Coordinated Time lt main gt lt recordGroup gt lt device gt lt device gt lt record gt lt dateTime gt lt dateTime gt lt field gt lt id gt lt id gt lt value gt lt value gt lt field gt lt record gt lt recordGroup gt lt main gt main field identifying the XML as a request recordGroup field that groups all the recordings of an event device device the records make reference to record identifies each recording dateTime event date and time field identifies each field id Identifier value event value 4 3 8 Active Events EDS 3G has an XML active events service whose aim is to enable an external agent or integration system to be registered as a listener and record the events or alarms that occur in the device The device keeps a distribution list of active users to which it sends events that take place locally via the creation of incidents 4 3 8 1 Test commands Before initiating implementation of the active events system there are a number of PUT type test requests between the listener and the producer remote engine and vice versa the aim of which is to test and ensure connectivity between both systems The listener can send the request with th
14. e device connection process The devices start the communication process with the remote connections server by creating a transparent communications tunnel between the device and connection server Therefore the user avoids having to hire and maintain a fixed IP system or DynDNS in its remote control locations Once the connections have been received by a central computer said connections are shared by a local DNS name server hosted in a machine with the software supplied with the EDS device 2 2 11 2 1 CirDNS host Enter the name with which the local DNS name server will be identified when it is connected to the central server For example when configuring 25001 when it is connected to the main server the server will identify it with the local DNS name after the name server has been installed refer to the CirDNS user manual The cursor is enabled with the SCROLL RIGHT key and the SCROLL UP and SCROLL DOWN buttons can be used to establish the parameters of an alphanumeric data entry Validate the data by pressing the SCROLL DOUN key 2 2 11 2 2 CirDNS password An authentication password can be activated in the CirDNS system installed on the server to provide access to the remote devices machine In this case the EDS 3G units that wish to connect to the machine must have an access password established for such purposes The cursor is enabled with the SCROLL RIGHT key and the SCROLL UP and SCROLL DOWN buttons can be
15. e following message body to check connectivity with the remote search engine producer http ip_producer port services user testListener xml lt listener gt lt ijp gt ip_listener lt ip gt lt port gt 80 lt port gt lt listener gt ip_listener defines the listener s IP to which the producer sends the response request port defines the listener s port to which the producer sends the response request When the producer remote search engine receives the test request from the listener it returns the following request http ip_listener port services user testProducer xml request to which the listener must reply with received 200 4 3 8 2 Registration of a listener Any agent or istener who wants to register in a remote search engine or producer so as to receive the incidents recorded by the search engine in real time must make the following PUT request to the producer with this format http ip_producer port services user listener xml This request must contain the following body in the message in which the listener and the type of data to be received are defined lt listener gt lt ijp gt ip_listener lt ip gt lt port gt 80 lt port gt lt all gt T lt all gt lt listener gt ip_listener the listener s IP is defined to which the producer sends the events that are generated port defines the listener s port to which the producer sends the events that are created The all section def
16. ection coverage Said coverage can oscillate from 113 dBm to 51 dBm The latter is considered as the value with the highest coverage These values may be known by accessing the following website http 00x xxx xxx xxx html modem status html http dhcp_name html modem status html Where xxx xxx xxx xxx is the IP address assigned by the user Where dhcp_name is the name assigned and authenticated by the name server of the local area network LAN or a DNS server in case of using a DynDNS system to connect to the Internet 2 2 17 Internal configuration web site After establishing the parameters with the keyboard and connecting to the Ethernet or even from the unit s Internet connection the device has a configuration web site where the user can fully modify the data entered with the keyboard The configuration web site is at the http address below http 400 xxx xxx xxx html setup html http dhcp_name html setup html Where xxx xxx xxx xxx is the IP address assigned by the user Where dhcp_name is the name assigned and authenticated by the name server of the local area network LAN or a DNS server in case of using a DynDNS system to connect to the Internet 2 3 Network parameters configuration Software Configuration of addressing can be done in the same way as using the keyboard via the IPSetup exe file available on a CD supplied with the device 2 3 1 Fixed IP assignment To assign a fixed IP address e
17. ed in the information query must be included in the request as id device1 id device2 http x x x x services user devicelnfo xml id dispositivo http nombre_dhcp services user devicelnfo xm id dispo lt devices gt lt device gt lt id gt lt id gt lt description gt lt description gt lt type gt lt type gt lt typeDescription gt lt typeDescription gt lt Var gt lt Var gt lt device gt lt devices gt description description of device type device type typeDescription detailed description of the device var name of each of the variables of the device expressed as name variable 4 3 3 Information about the variable The user can request detailed information about one or more variables from a device and even make one single request for the information about all the variables available in the device 4 3 3 1 Information about one or more variables Request for detailed information about one or more variables of the device if information is needed about more variables link the other requests below with var device variable M98240601 03 13B m CIRCUTOR http x x x x services user var Info xml var device variable http name_ dhcp services user var Info xml var device variab le 4 3 3 2 Information about all the variables Request for detailed information about all the variables of the device if information is needed about more devices link the
18. figuration and display accesses keyboard Web configuration and internal applications To modify the option displayed on screen SERGLL RIGHT until the option 4 amp 5 appears Do this twice and the device cyclically displays both options until one of them is validated Establish the parameters for the alphanumeric data entry with the SCROLL UP and BOLIN buttons up to 20 digits corresponding to the USER and when the data is validated repeat the operation with the PASSWORD Validate the data SCROLL RIGHT and SCROLL DOWN 2 2 13 Confirm Changes DHCP YES The information must be validated to save the configuration The device displays 4 amp 5 by default When the completed configuration is validated press the SCROLL DOWN key and the device saves the data and leaves configuration If the configuration is not saved SCROLL RIGHT until the NG option appears Do this twice and the device cyclically displays both options until one of them is validated with the SCROLL DOUN key 2 2 14 Client ID DHCP NO 3 If the DHCP server is not activated shown in section 2 2 2 DHCP assignment validate the 2 option using the SCROLL DOUN key and go to the next screen 2 2 14 1 IP DHCP NO The user configures an IP address for the EDS 3G device using this configuration option To configure them press the SCROLL RIGHT key enabling the edit cursor on the first digit Press the SCROLL UP and DOUN buttons to establish the parame
19. ines the type of information that is to be accessed True False True indicates to the producer that all the active events list available must be sent False indicates to the producer that only the events that took place since the last request must be sent M98240601 03 13B m CIRCUTOR 4 3 8 3 Deletion or loss of the listeners list The producer can completely or partially lose or eliminate the listeners list for different reasons The listener does not answer when new events or changes in these events take place the producer instantaneously informs all listeners on the list When the producer is faced with a communication problem with a listener a total of fifty retries are made to send information If the listener does not respond to these requests the producer deregisters the listener from the distribution list The producer has rebooted or has temporarily stopped operating if the producer receives an update or generates a reset for any reason firmware update loss of power supply etc the entire listeners list is lost and from then on stops sending events to the previously associated listeners 4 3 8 4 Maintenance of the listeners list alive Given that there are several reasons why the listeners list might be totally or partially affected the external integration system needs to implement an alive test system against the producer to ensure that the IP is kept active for a long pe
20. isation is completed via DHCP if the network server allows this to be done In this case it is the main server To configure an NTP server that is different from the DHCP 2 0 0 8 press the SCROLL RIGHT key enabling the edit cursor on the first digit Set parameters for an alphanumeric data entry with the SCROLL UP and BOWN buttons up to a maximum of 20 digits indicating an http address or internal or external IP if the device has Internet access After establishing the parameters press the SCROLL RIGHT key repeatedly until the edit cursor disappears and validate the data with the SCROLL DOUN key opening the next screen Servers available on the Internet es pool ntp org pool ntp org 2 2 9 Secondary NTP configuration of the secondary NTP server carry out the same procedure as with the Primary NTP 2 2 10 Time Zone Press the SCROLL RIGHT key to select the time zone where the EDS 3G device is located After selecting the zone press the SCROLL GOWN key and go to the next screen 2 2 11 Dyn DNS type The 29N DNS TYPE menu offers two dynamic communications systems when working with connections with no fixed IP and which require identification by a connection master To configure a dynamic system press the SCROLL RIGHT key until the desired system is selected SYNONS CIRONS or DISABLED After it has been selected press the SCROLL DOWN key to open the next screen 2 2 11 1 DynDNS System DYINDNS
21. ity test with an IP address or name emulating the ping command of a conventional operating system The device displays the physical address within the setup menu as shown in section 2 2 1 MAC address Press the SCROLL RIGHT key to go to the on screen caption HOST PING To enter the name or IP address to carry out the ping test press the SCROLL RIGHT key to enable the edit cursor on the first digit Press this key and the SCROLL DOWN and SCROLL UP buttons to establish the parameters of an alphanumeric data entry of up to 20 digits After the data is entered press the SCROLL RIGHT key twice until the edit key disappears and then validate the data with the SCROLL DOWN key When the data is validated the screen displays the 0iNG PING caption and will then show the results PING RESULT 04 a response was obtained from the host PING RESULT TINE GUT no response was obtained from the host When a result is obtained by the device press the SCROLL DOUN key and the device goes back to the by default display screens 2 2 16 Acquired IP and coverage Once the unit has been connected to the Internet two sensitive variables must be known by the user or integrator which are the IP acquired by the mobile phone telephony provider and the coverage signal the unit is connected to EDS 3G Press the SCROLL RIGHT and SCROLL LEFT keys at the same time and the unit will display on the screen the IP acquired by the operator and the conn
22. mmunications master and store data recorded in its 200Mb cyclic memory lts Web accessibility and memory enable the user to view data coming from devices connected to the bus in real time and easily and simply view graphics and tables of the parameters registered by the device As well as linking communications with devices connected to its RS 485 communications bus the device also has the Capacity to make connections via IP connectivity local or remote either through an IP via addressing or DHCP name To add devices to the configuration of the EDS 3G energy PLC the user must install the PowerStudio or PowerStudio Scada application so as to export a new configuration of the device adding new analyzers or slaves connected to the unit EDS 3G allows the configuration of up to 5 slave devices connected to its network 3 6 Additional PS PSS features To configure the other system features read the PowerStudio Scada Editor manual It has all the information the user needs about Importing or exporting the configuration of the EDS 3G system Configuration of new devices or slaves Tariff discriminators calendars Calculated variables System events and alarms Authentication configuration Web system security Ete Without the PowerStudio Editor tool the measurement application cannot be configured to provide new features for the EDS 3G device Consequently the user must install the software thus maki
23. ng it possible to fully configure the display server and vary the settings of the display connected devices alarms etc 4 XML instructions Not only does EDS 3G function as an excellent energy efficiency manager for local and multi point networks it also has a default XML requests server that enables it to be easily and intuitively integrated into a SCADA or remote monitoring system The device via its IP address responds to GET and PUT requests being able to carry out different functions on the device 4 1 Type of variables The device has a list of available variables in accordance with the device s features The basic code is made up of the device name and the variables separated by a dot name variable This way the software knows which variable it is and what device must be asked to find out the value of the variable When an incremental variable is discriminated energy impulse energy meter or similar the information about the parameterised discriminator is added to the basic code name_discriminator type_time variable The discriminable variables are shown in the list with an asterisk EDS 3G 4 2 EDS 3G variables list If slave devices are provided the frames sent to EDS 3G are identified in the same way by name and variable as shown in section 4 1 The following table shows the definition of the variables XML Status Value XML Energy Meter Value available in EDS 3G Digital inp
24. nter the MAC address displayed on the device screen as shown in section 2 2 1 MAC address address the format of which is 08 26 45 XX XX XX MAC 00 26 45 00 01 9F Direcci n 172 16 4 130 Netmask 255 255 0 0 Gateway 172 16 4 1 In the Address field enter the IP address being configured performs the same operation with the Netmask After entering the device configuration press Configure to send the configuration to the unit 2 3 2 DHCP IP assignment To assign the DHCP name activate the option using the upper right hand arrow and select On Once the configuration fields have been enabled enter the MAC address In the Address field enter an unused temporary IP address which is within the working range of your computer In the Host Name field enter the DHCP name to be assigned to the equipment Optionally the user can configure the parameters of the ClientID field The default VendorlD of the device is CIRCUTOR MAC Host Name 00 26 45 00 01 9F bus 1 Direcci6n Client ID 172 16 4 130 Netmask Primary DNS Server _ Gateway Secondary DNS Server 2 3 3 Configuration web site Once connection to the Local Area Network LAN is established and the IP address or DHCP name is configured the device has an internal web site where the user can fully modify all the network configuration parameters 0 Where XXX XXX XXX XXX s the IP address assigned by the user
25. ork parameter configuration Keyboard The configuration of the Ethernet network parameters can be fully carried out using the function buttons on the front panel of the device To access the setup menu simultaneously hold down the keys SCROLL RIGHT SCROLL UP and SCROLL GOWN for more than two seconds The device shows the text HOLD ON 2 SECONDS TO ENTER SETUP on screen and after 2 seconds the display shows ENTERING SETUP RELEASE THE KEYS 2 2 1 MAC address After entering the setup menu the device displays MAC Media Access Control physical address on screen with a 08 26 45 XX XX XX type format This is an information panel that the user can use to know the physical address of the device To go the next setup screen press the SCROLL DOUN key 2 2 2 DHCP assignment After entering the setup menu the device displays GHfP Dynamic Host Configuration Protocol and shows the by default option To modify the option displayed on the screen press SCROLL RIGHT until the YES option appears Do this twice and the device cyclically displays both options until one of them is validated When the DHCP server is activated via the 4 5 caption press the SCROLL DOUN key to go to the next option 2 2 2 1 Client ID DHCP YES After activation of the DHCP authentication and the subsequent validation the device displays the CLIENT if parameter configuration on the screen which makes reference to the DHCP name of the device to
26. other requests below with id device http x x x x services user varlInfo xml id dispositivo http nombre_dhcp services user var Info xml id dispositivo lt varlnfo gt lt var gt lt id gt lt id gt lt title gt lt title gt lt hasValue gt T lt hasValue gt lt hasLogger gt T lt hasLogger gt lt sampleMode gt lt sampleMode gt lt measureUnits gt lt measureUnits gt lt unitsFactor gt lt unitsFactor gt lt decimals gt lt decimals gt lt var gt lt varInfo gt id variable name in device variable format title brief description of the variable hasValue indicates if it is possible to request the instantaneous value of the variable True False hasLogger indicates if it is possible to request the log of the variable True False sampleMode type of variable and mode used to group values measureUnits variable unit unitsFactor power of 10 indicating the multiplying factor in the log file decimals decimals of the variable 4 3 4 Instantaneous variable value The user can request the instantaneous values of one or more variables and can even request the information about all instantaneous values with a single request 4 3 4 1 Instantaneous value of one or more variables Request for the instantaneous value one or more variables of the device if information is needed about more variables link the other requests below with var devi
27. ower supply and CPU activity Communicating slave devices shutdown GPRS or 3G connection linked to the operator Green Full duplex Yellow Half duplex Activity Green 100 Mb s Yellow 10 Mb s Link 2 lines alphanumeric 20 Yes Installation category Class IlI EN61010 double insulated electric shock protection class Il Connect the device to a power circuit protected with gl fuses in compliance with IEC 269 or M fuses with values from 0 5 to 1A It must be fitted with a circuit breaker switch or equivalent device in order to be able to disconnect the device from the power supply The GSM 850 900 1800 1900 Band Serial interface Type Transmission speed configurable Data bits 8 Parity Stop bit 1 Three wire RS 485 A B S 4800 9600 19 200 34 800 57 600 115 200 bps Standards power supply cable must have a cross section of at least 1mm EC UL 94 EN61010 1 EN55011 EN 61000 4 2 EN 61000 4 3 No parity odd even 61000 4 11 EN 61000 6 4 EN 61000 6 2 EN 61000 6 1 EN 61000 6 3 EN 61000 4 5 M98240601 03 13B 6 Connecting and inserting the SIM card DETAILS OF THE POWER SUPPLY AND RS 485 COMMUNICATION DETAILS OF DIGITAL INPUT 4 ACTIVATION SLAVE EQUIPMENT CONNECTIONS 16066606066 foo000000 Transmiter Emisor Cin Ina In2 Ins Ina INS Ine In7 Ine Cin l OOOO OO00000000 fh j 0000000000 7 Technical Service If you have any doubts about the operation of the unit
28. riod in the distribution list It is recommended that the test system is automatic and at intervals of no more than 10 minutes between each test frame dispatch The alive test system is based on the updating of the listener IP again against the producer although only the event changes are requested False http ip_producer port services user listener xml This request must contain the following body in the message in which the listener and the type of data to be received are again defined lt listener gt lt ijp gt ip_listener lt ip gt lt port gt 80 lt port gt lt all gt F lt all gt 5 Technical features Power circuit Single phase phase neutral Al A2 Frequency Maximum consumption Working temperature Humidity non condensing Mechanical features Case material Device protection degree Dimensions mm Weight Maximum operating height Inputs features Type Maximum activation current Insulation Network interface Type Connector Network protocols Modem Work bands Data only Standard version 85 264 Vac 120 300 Vac 50 60 Hz 6 10 VA AC 3 4 W DC 10 60 2C 5 95 UL94 V0 self extinguishing plastic IP 20 105 x 70 x 90 mm 6 modules 385 g 2 000 m Voltage free opto insulated dry contact 50 mA 1500 V Ethernet 10BaseT 100BaseTX self detectable RJ 45 HTTP Modbus RTU in RS 485 bus UMTS HSPA 2100
29. s Power Slaves GPRS 3G link LeftR 45 led Right RJ 45 led Display Type Characters Back lighting Safety Maximum operating power Maximum operating voltage Maximum switching current Electrical life 250 Vac 5 A Mechanical working life EDS 3G lt whyFired gt DEACTIVATION lt whyFired gt lt event gt lt producer gt all all the events True or changes False event id producer and identifier of the event whyFired ACTIVATION DEACTIVATION Notes referring to the active events Note if the producer has implemented http authentication by user and password it must be implemented in the listener by the user 4 3 9 Forcing of variables This request is used to send the variable forcing order or writing to the system The request should include the name of the device that wants to make the request It is important to incorporate the authentication data when this is necessary lt force Variables gt lt forceVar gt lt forceName gt lt forceName gt lt forceValue gt lt forceValue gt lt record gt lt force Var gt lt force Variables gt forceVariables field identifying the XML as a request forceVar Information from each variable to be forced forceName variable name in device variable format field identifies each field Relay 750 VA 250 Vac 5 A with resistive load 3 x 104 operations 2 x 107 operations Equipment p
30. s The buttons have the following functions SCROLL LEFT edit button scrolls the cursor to the left to modify the numerical or alphanumeric digit SCROLL RIGHT edit button scrolls the cursor to the right to modify the numerical or alphanumeric digit SCROLL UP the function of this button is to modify the digit where the edit cursor is located If there is no cursor on the screen move up to the next step of the previous configuration option SCROLL DOWN the function of this button is to modify the digit where the edit cursor is located If there is no cursor on the screen move down to the next step of the previous configuration option 2 Configuration The device has two clear configuration routes the first one is related to the Ethernet network IP addressing and GPRS 3G network integration start up and the second one is related to the configuration of the internal application and possible association with other field devices via the RS485 bus 2 1 Network addressing EDS 3G is a device with self detecting Ethernet 10 100BaseTX connectivity This means that in order to integrate the device into a Local Area Network it must be provided with a previous IP addressing configuration The user can access the configuration parameters via the display and the function keys on the front panel of the device or through the internal configuration web site which is accessible via a conventional Internet browser 2 2 Netw
31. ters of a 000 000 000 000 type numeric data entry After establishing the parameters press the SCROLL RIGHT key repeatedly until the edit cursor disappears and validate the data with the SCROLL DOUN key opening the next screen 2 2 14 2 NetMask DHCP NO 3 To configure the NetMask configuration press the SCROLL RIGHT key activating the edit cursor on the first digit Press the SCROLL UP and DAWN buttons to establish the parameters of a 000 000 000 006 type numeric data entry After establishing the parameters press the SCROLL RIGHT key repeatedly until the edit cursor disappears and validate the data with the SCROLL DOUN key Opening the next screen 2 2 14 3 Other configurations DHCP NO After configuring the secondary DNS the other setup screens correspond to the same ones as in the activated DHCP mode consequently the configuration procedure will be the same as the one for sections 2 2 3 APN Modem 2 2 4 User modem 2 2 5 Password modem 2 2 6 PIN modem 2 2 7 Reset modem 2 2 8 Primary NTP 2 2 9 Secondary NTP 2 2 10 Time Zone 2 2 11 Dyn DNS type 2 2 12 Enable Security 2 2 13 Confirm Changes DHCP YES 2 2 14 4 Manual Date and Time Configuration If there is no authentication configuration by the DHCP system and if there is no Primary and Secondary NTP server available EDS 3G allows the time and date to be configured manually when valida
32. ting the changes by displaying the caption ADJUST CLOCK The date and time are displayed on screen with the following format 999 fif 00 HH To configure them press the SCROLL RIGHT key enabling the edit cursor on the first digit Use the SCROLL UP and SERGLL DOUN buttons to establish the parameters of the numeric data entry After establishing the parameters press the SCROLL RIGHT key twice until the edit key disappears and then validate the data with the SCROLL DOWN key leaving setup and validating the configuration When the configuration is validated the DENE caption appears returning to the main screen 2 2 15 Display of configuration parameters To display the configuration parameters the user must enter the setup menu by simultaneously pressing the SCROLL RIGHT SCROLL UP and SCROLL DOUN KEYS THE USER MUST Press the SCROLL DOUN key twice for complete visualisation of the device configuration If a user and password are available even when the user does not have one all the configuration parameters can be visualised without being able to change them asterisk in top left hand corner 2 2 15 1 Ping system To confirm IP connectivity via a Local Area Network LAN or the Internet using a DSL or 3G router the user sometimes has to know if the EDS 3G device has this IP access or if the unit has particular access to a certain host To do so EDS 3G has a PING section from which the user can carry out an IP connectiv
33. ty water gas meters etc The value of these impulses is linked to 8 memory records stored in a non volatile memory Each registry is 32 bits 4 bytes so it counts a maximum of up to 4 294 967 295 impulses When a memory record reaches this value the energy meter is reset back to zero The minimum duration of the impulse or status change of the digital input must be 50 ms The minimum time between two successive impulses must also have a minimum duration of 50 ms This represents a maximum sampling frequency of 10 Hz Its Web server and internal memory enable the user to extract graphics and tables of impulses received during a certain period table and graphic function 3 3 2 Input logical status function 0 1 The 8 digital inputs in the device are voltage free and have an input logical status detection function This means that when a bridge is set up between the common and one of the digital inputs the device detects that the input has closed and displays the status via both communications servers 3 4 Digital outputs The device has 6 relay digital outputs The user can use remote control to carry out actions on the outputs open close create an impulse These actions can be manual or via programming in the events section of the device see PowerStudio Scada manual 3 5 RS 485 expansion bus The device has an RS 485 communications bus that allows it to communicate with external peripherals act as a co
34. used to establish the parameters of an alphanumeric data entry Validate the data with the SCROLL DOUN key 2 2 11 2 3 CirDNS server Enter the destination IP or DNS name where the device will be actively connected This is an alphanumeric field The cursor is enabled with the SERGLL RIGHT key and the SCROLL UP and SCROLL DOWN buttons can be used to establish the parameters of an alphanumeric data entry Validate the data with the SCROLL DOUN key 2 2 11 2 4 CirDNS port Enter the port used to access the central server where the CirDNS connections software was installed This computer must have an access port used to connect all remote devices in order to establish a transparent communications tunnel In this case access to the Internet connection from the central location will require the use of a connection router which will establish a NAT access rule to activate a UDP connection port in the connection server connection path An access port must be activated in the Internet access router which will internally transfer the public communication frames to the CirDNS internal connection server and to a port specified by and known to the user 2 2 12 Enable Security A user and edition password can be activated in the device thus avoiding modification of the configuration parameters The device displays NG by default It should be pointed out that if the password is activated it will be present in all the device s con
35. uts Digital Input 1 Digital input 2 Digital input 3 Digital input 4 Digital input 5 Digital input 6 Digital input 7 Digital input 8 Digital Output Status Digital Output 1 Digital Output 2 Digital Output 3 Digital Output 4 Digital Output 5 Digital Output 6 Forced Outputs Impulse Digital Output 1 Digital Output 2 Digital Output 3 Digital Output 3 Digital Output 5 Digital Output 6 Date and time Date and Time Device status Device status Values Communication OK Not initialized XML Impulse STATUS 34 Comm Errors Device incorrect 4 3 XML Services The requests must follow the URI standard RFC 2396 so the user of these requests should take this detail into account when making such calls especially in cases where the name of any device contains non ASCII characters Take into account that the length of the request must not under any circumstance exceed 4000 characters 4 3 1 Configured devices request With this request the XML service returns the list of connected devices to the EDS 3G energy efficiency manager http x x x x services user devices xml http nombre_dhcp services user devices xml lt devices gt lt id gt lt id gt lt devices gt devices field identifying the XML as a response to the device list request id name of each one of the devices 4 3 2 Information about the device With this request the XMP service returns information about the devices Each device includ