image

Contents

1. 30 1 5 5 System Block Diagram S7086 32 33 Chapter 2 Setting UD 36 2 0 1 Before you Begin 36 20 2 WB ONG AlE aan 36 2035 una an 36 2 0 4 Precautions 37 2 1 Installing Motherboard Components 38 2 1 1 Removing the Chassis Cover 38 2 1 2 Removing the Riser Card Brackets 40 2 1 3 Installing the CPU and Heatsink 41 2 1 4 Installing the Memory 44 2 1 4 Installing Hard Drives 48 2 1 5 Installing the PCI E Cards 51 2 2 Rack mens o3 2 2 1 Installing the Server in a Rack o3 2 2 2 Removing the Server from a of Chapter 3 Replacing Pre Installed Components 58 i essi 58 3 2 Disassembly Flowchalrt 58
2. 82 Appendix III Fan and Temp Sensors 84 Appendix IV Technical Support 89 14 http www tyan com Chapter 1 Overview 1 5 About the TYAN GN70 B7086 Congratulations on your purchase of the TYAN GN70 B7086 a highly optimized rack mountable barebone system The 70 7086 is designed to support dual Intel Xeon E5 2600v3 series HSW EP Processors and up to up to 32GB RDIMM and 64GB LRDIMM and 128GB LRDIMM 3DS DDR4 memory for each DIMM slot providing a rich feature set and incredible performance Leveraging advanced technology from Intel the GN70 B7086 server system is capable of offering scalable 32 and 64 bit computing high bandwidth memory design and lightning fast PCI E bus implementation The GN70 B7086 not only empowers your company in nowadays IT demand but also offers a smooth path for future application usage TYAN also offers the GN70 B7086 in a version that can support up to eight 3 5 or 2 5 hot swap hard drives The GN70 B7086 uses TYAN s latest chassis featuring a robust structure and a solid mechanical enclosure All of this provides GN70 B7086 the power and flexibility to meet the needs of nowadays server application 1 2 Product Models Model HDD Bays Motherboard B7086G70V6E2HR Hot swap 8HDDs S7086GM3NRE B7086G70V8HR Hot swap 8HDDs S7086GM3NR 15 http www t
3. Before you Begin This chapter explains how to install the CPUs CPU heatsinks memory modules and hard drives Instructions on inserting add on cards are also given Work Area Make sure you have a stable clean working environment Dust and dirt can get into components and cause malfunctions Use containers to keep small components separated Putting all small components in separate containers prevents them from becoming lost Adequate lighting and proper tools can prevent you from accidentally damaging the internal components Tools The following procedures require only a few tools including the following Across head Phillips screwdriver A grounding strap or an anti static pad Most of the electrical and mechanical connections can be disconnected with your hands It is recommended that you do not use pliers to remove connectors as it may damage the soft metal or plastic parts of the connectors Caution 1 To avoid damaging the motherboard and associated components do not use torque force greater than 7kgf cm 6 09 Ib in on each mounting screw for motherboard installation Do not apply power to the board if it has been damaged 36 http www tyan com 2 0 4 Precautions Components and electronic circuit boards can be damaged by discharges of static electricity Working on a system that is connected to a power supply can be extremely dangerous Follow the guidelines below to avoid damage to GN70 B7086 o
4. ICH SMBDAT ICH SMBCLK INTRUZ LAN2 LED LAN2 LED Definition VCC USB2 USB2 GND GND http www tyan com 3 Replacing the System Fan Follow these instructions to replace the system fan 1 Press the latch in the direction as shown to lift up the fan from cage 4 LJ Pot 2 Take out the fan unit 3 Loose the screws on both sides 69 http www tyan com 4 Push the latch in the direction as the arrow shown to release the fan from the iron holder 5 Remove the holder to replace a new fan 6 After replacing a new one put the fan unit back into the cage 70 http www tyan com 3 8 Replacing the Fan Backplane Board Follow these instructions to replace the M1806G70 FB Fan Backplane Board in your system 1 Press the latch in the direction as shown to lift up the fan from cage 4 Li A 2 Remove all four fans from the chassis 3 Disconnect all cables attached to the Fan Backplane Board 71 http www tyan com 4 Use a screw driver to unscrew the Fan Module 5 6 Lift up the Fan Module Em Cyc CHWs 72 http www tyan com 7 Release the 14 screws on the Fan Backplane Board to replace a new 8 Follow the steps described in reverse order to reinstall the fan cage 73 http www tyan com 3 8 1 Fan BP Board Specifications Here shows the M1806G70 FB Fan Backplane Board in
5. TYAN GN70 B7086 Service Engineer s Manual 1 http www tyan com 2 http www tyan com Copyright This publication including all photographs illustrations and software is protected under international copyright laws with all rights reserved Neither this manual nor any material contained herein may be reproduced without written consent of manufacturer Copyright 2015 MiTAC International Corporation All rights reserved TYAN is a registered trademark of MiTAC International Corporation Version 1 0 Disclaimer Information contained in this document is furnished by MiTAC International Corporation and has been reviewed for accuracy and reliability prior to printing MiTAC assumes no liability whatsoever and disclaims any express or implied warranty relating to sale and or use of TYAN products including liability or warranties relating to fitness for a particular purpose or merchantability MiTAC retains the right to make changes to produce descriptions and or specifications at any time without notice In no event will MiTAC be held liable for any direct or indirect incidental or consequential damage loss of use loss of data or other malady resulting from errors or inaccuracies of information contained in this document Trademark Recognition All registered and unregistered trademarks and company names contained in this manual are property of their respective owners including but n
6. Follow latest Intel DDR4 Memory POR 4 Channels per CPU 6 PCI E Gen3 x16 slots w x8 link 1 OCP slot for Mezz Card 1 Proprietary slot for SAS Mezz Card M7062 B811 1T PCI E Gen3 x8 Broadcom 10GbE Mezz Card M7062 B810 2T PCI E Gen3 x8 Broadcom 10GbE Mezz Card M7076 X540 2T PCI E Gen3 x8 Intel 10GbE Mezz Card M7076 3108 8l PCI E Gen3 x8 LSI SAS 12G Mezz Card M7094 2308G 8l PCI E Gen3 x8 LSI SAS 6G Mezz Card M7076 3008 8l PCI E Gen3 x8 LSI SAS 12G Mezz Card M7076 1350 PCI E Gen3 x8 Intel 2 GbE Mezz Card 7062 1599 1 PCI E Gen3 x8 Intel 10GbE Mezz Card M7062 1599 2T PCI E Gen3 x8 Intel 10GbE Mezz Card M7056 L24 3F M7056 R24 3F 3 GbE ports Intel 1350 AM2 Intel 1210 1 Mini SAS 4 ports 2 SATA totally support 6 ports Intel C612 6 0 Gb s RAID 0 1 10 5 Intel RST 19 http www tyan com Graphic I O Ports System Monitoring Server Management BIOS Operating System Regulation Operating Environment RoHS Package Contains Connector 1 Mini SAS 4 ports Controller SSATA Speed RAID Connector type Resolution Chipset USB COM VGA RJ 45 Chipset Voltage Temperature LED Others Onboard Chipset AST2400 IPMI Feature AST2400 iKVM Feature Brand ROM size Feature OS supported list FCC DoC CE DoC Operating Temp Non operating Temp In Non operating Humidity RoHS 6 6 Complia
7. customer support through email By offering plenty of options for users MITAC serves multiple market segments with the industry s most competitive services to support them Please feel free to contact us directly for this service at tech support tyan com Help Resources 1 See the beep codes section of this manual 2 See the TYAN s website for FAQ s bulletins driver updates and other information http www tyan com 3 Contact your dealer for help before calling TYAN 89 http www tyan com Returning Merchandise for Service During the warranty period contact your distributor or system vendor FIRST for any product problems This warranty only covers normal customer use and does not cover damages incurred during shipping or failure due to the alteration misuse abuse or improper maintenance of products NOTE A receipt or copy of your invoice marked with the date of purchase is required before any warranty service can be rendered You may obtain service by calling the manufacturer for a Return Merchandise Authorization RMA number The RMA number should be prominently displayed on the outside of the shipping carton and the package should be mailed prepaid TYAN will pay to have the board shipped back to you TYAN GN70 B7086 Service Engineer s Manual V1 0 Document No D2159 100 90 http www tyan com
8. CPUO DIMM D1 CPU1 DIMM EO CPU1 DIMM E1 CPU1 DIMM FO CPU1 DIMM F1 CPU1 DIMM GO CPU1 DIMM G1 CPU1 DIMM HO CPU1 DIMM H1 ke 1111 18111112 18 18 LEER EP eT TT Tekk kkkh AeH EL EE k e ke Ae kkh e kH ekke eke lt j 2 J e j2 46 http www tyan com Intel Xeon processor E5 2600v3 product families Support Speed MT s Voltage V Slot Per Channel SPC and DIMM Per Channel DPC Ranks Per DIMM Capacity 1 Slot Per 2 Slots Per Channel 3 Slots Per Channel 1DPC 1DPC 2DPC 1DPC 2DPC 3DPC 1 2V 1 2V 1 2V 1 2V 2133 2133 1866 2133 1866 1600 2133 2133 1866 2133 1866 1600 2133 2133 1866 2133 1866 1600 2133 2133 1866 2133 1866 1600 LRDIMM 2133 2133 2133 2133 2133 1600 SRx4 2133 2133 2133 2133 2133 1600 NOTE 1 1DPC One dimm per channel NOTE 2 2DPC gt Two dimm per channel Physical Ranks are used to calculate DIMM Capacity Supported DRAM Densities are 4Gb 8Gb 47 http www tyan com 2 1 5 Installing Hard Drives The GN70 B7086 can support up to eight 8 3 5 or 2 5 hard drives Follow these instructions to install a hard drive 1 Press and hold the locking lever latch to pull the locking lever open 2 Slide the HDD tray out 48 http www tyan com Option A for 2 5 hard drives Place 2 5 hard drive into the HDD tray and use 4 screws to secure the
9. Replace a new HDD BP Board and reinstall it into the chassis following the steps in reverse 76 http www tyan com 3 9 1 HDD BP Board Specifications Here shows the M1276GN70 12 8 Fan Backplane Board in details Front View Mini SAS HD Connector 8 pin Power Connector PW4 without M1276GN70 BP12 8 Mini SAS HD Connectors SGPIO Mini SAS Connector Mini SAS Connector Rear View 332 82 5mm 8 layer PCB One 1 2x5 pin SGPIO connector Support 4 68 pin SAS PCle connectors 4 NVMe devices Int ted I O Support 4 29 pin SAS connectors 4 HDD devices Support P mini SAS HD connectors connect MB Support 2 mini SAS connectors connect MB Support 8 HDD Failed LED Support 8 HDD Access LED 77 http www tyan com PW4 Pin definition Definition GND GND Definition SMBUS 3V3 CLK 1 6 SAS GPIO2 SAS 2 KEY SAS GPIO3 SAS GPIO1 4 9 VCC3 GND 10 HD ERR LED 78 http www tyan com 3 10 Replacing the Power Supply The system has two pre installed 1 600W 80 Platinum Power Supply Units Follow these instructions to replace the power supply units 1 Press and hold the latch to pull the power supply out 2 After replacing a new power supply press and hold the latch to push the power supply back into the chassis 79 http www tyan com Appendix Cable Connection Tables 1 Mini SAS Cable For B7086G70V6E2HR SKU SAS SATA Backplane S
10. case the user will be required to correct the interference at his own expense Notice for Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la Classe A est conforme la norme NMB 003 du Canada Notice for Europe CE Mark This product is in conformity with the Council Directive 2004 108 EC CAUTION Lithium battery included with this board Do not puncture mutilate or dispose of battery in fire There will be danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by manufacturer Dispose of used battery according to manufacturer instructions and in accordance with your local regulations 4 http www tyan com About this Manual This manual provides you with instructions on installing your TYAN GN70 B7086 This Manual is intended for experienced users and integrators with hardware knowledge of personal computers This manual consists of the following parts Chapter Chapter2 Chapter3 Appendix Provides an introduction to the TYAN GN70 B7086 barebones standard parts list describes the external components gives a table of key components and provides block diagram of the system Covers procedures on installing the processor memory modules and hard drives Covers the removal and replacement procedures for pre installed components List the cable connection and FRU part tables for reference of syste
11. com Safety Information Retain and follow all product safety and operating instructions provided with your equipment In the event of a conflict between the instructions in this guide and the instructions in equipment documentation follow the guidelines in the equipment documentation Observe all warnings on the product and in the operating instructions To reduce the risk of bodily injury electric shock fire and damage to the equipment observe all precautions included in this guide You must become familiar with the safety information in this guide before you install operate or service TYAN products Symbols on Equipment Caution This symbol indicates a potential hazard The potential for injury exists if cautions are not observed Consult equipment documentation for specific details Warning This symbol indicates the presence of hazardous energy circuits or electric shock hazards Refer all servicing to qualified personnel Warning This symbol indicates the presence of a hot surface or hot component If this surface is contacted the potential for injury exists To reduce risk of injury from a hot component allow the surface to cool before touching General Precautions Follow all caution and warning instructions marked on the equipment and explained in the accompanying equipment documentation Machine Room Environment Make sure that the area in which you install the system is properly ventilated and cli
12. service provider Examples of damage requiring service include The power cord extension cord or plug has been damaged Liquid has been spilled on the product or an object has fallen into the product The product has been exposed to rain or water The product has been dropped or damaged The product does not operate normally when you follow the operating instructions 11 http www tyan com 12 http www tyan com Table of Contents Chapter 1 Overview 15 1 5 About the TYAN GN70 B7086 15 122 Product Mod618 u uuu uuu aan 15 EE OA 16 1 4 Standard Parts List 21 1 41 Box Contents 21 1 4 2 Accessories 22 1 5 About the Product 24 1 5 1 System Front View 24 1 5 2 System Rear View 27 1 5 3 Motherboard 57086 Layout 29 1 5 4 Jumpers amp Connectors
13. 3 3 REMOVING the Cover 59 3 4 Replacing Motherboard Components 59 3 4 1 Replacing PCI E Riser Card 59 3 42 Disconnecting All Motherboard Cables 62 3 4 3 Removing the Motherboard 63 3 5 Replacing the Power Distribution Board 64 3 6 Replacing the Front Panel Board 65 13 http www tyan com 3 6 1 Front Panel Board Specifications 67 3 6 2 Connector Pin Definition 68 3 7 Replacing the System Fan 69 3 8 Replacing the Fan Backplane 71 3 8 1 Fan BP Board Specifications 74 3 8 2 Fan BP Board LED Definitions 14 3 8 3 Connector Pin Definitions 15 3 9 Replacing the HDD Backplane Board 76 3 9 1 HDD BP Board Specifications 77 Appendix Cable Connection Tables 80 Appendix II FRU Parts Table
14. ATAO 3 SATAO 3 2 SSATAO_3 NVMEO SAS gt SAS HD2 For B7086670V8HR SKU SASISATA Backplane 4 7 SSATAO 3 2 FAN Control Cable FAN Board J8 gt FAN HD1 3 Front Panel Control Cable Front Panel Board gt FP HD1 4 USB Cable Front Panel Board J1 gt USB2 5 Power Cable Power Board a 1 MB1 PW2 PATX2 MB2 PW3 gt J7 PSMI PSMI HD1 80 http www tyan com 6 Power Cable Power Board Corner to FAN Board M1601T70 D PDB M1806G70 FB PW4 FAN BD1 PW2 PW5 FAN BD2 r2 Power Cable Power Board Conecte to SAS SATA Backplane 1601 70 M1276G70 BP12E 8 PATX6 HDD BP1 PWA 81 http www tyan com Heatsink Rack Mounting FRU PS 0100 CFAN 0330 FRU TH 0140 M7056 R24 3F M7056 L24 3F M7086 R24 3F CRAL 0190 CCBL 0290 CCBL 0280 CCBL 0688 Appendix Il FRU Parts Table 471100000247 336252012309 343751200003 411743900115 411743900114 541175290004 452744600001 332810000281 332810000397 422797000003 82 http www tyan com F POWER SUPPLY SBU 770 DELTA DPS 770GB C SOF 1U MODULE REV SOF 12000RPM 60 60 38mm 4pin F HEATSINK SBU CU VC SOLDE RLING 2011 1U SPECIAL PASSIVE HEATSINK 0P305224 108 0X82 0X25 0 MM CREW GF83 B7094 PCI E x16 2U Riser Card PCI E x16 2U Riser Card F Riser ard SBU M7086 R24 3F R01 T
15. HDD Option B for 3 5 hard drives 4 Unscrew the drive bracket from the HDD tray 49 http www tyan com 5 Place 3 5 hard drive into the drive tray and use 6 screws to secure the HDD 6 Reinsert the HDD tray into the chassis and press the locking lever to secure the tray 50 http www tyan com 2 1 6 Installing the PCI E Cards The GN70 B7086 supports two PCI E Riser Card Brackets A power cable 2x3p 2x4p is required for GPU cards Follow these instructions to install PCI E cards 1 Unscrew the PCI E slot to take out the PCI bracket 2 51 http www tyan com 9 Repeat the same procedures for the second Riser Card Bracket NOTE Please add a 4 pin power cable to connect PDB J4 J5 to riser card M7056 L24 PWR1 M7056 R24 PWRI if the PCI E card needs more than 75W power and has no power connector to supply power M7056 L24 3F M7056 R24 3F J2 PWR1 GND 52 http www tyan com 2 2 Rack Mounting After installing the necessary components the TYAN GN70 B7086 can be mounted in a rack using the supplied rack mounting kit CRAL 0190 Rail Kit 2 2 1 Installing the Server in a Rack Follow these instructions to mount the TYAN GN70 B7086 into an industry standard 19 rack NOTE Before mounting the TYAN GN70 B7086 in a rack ensure that all internal components have been installed and that the unit has been fully tested However to make the installa
16. Panel Board 1 Unscrew to release the Front Panel Board Module 2 9 65 http www tyan com 4 Unscrew the Front Panel Board to replace a new one LJ is 9 Follow the steps described earlier in reverse to reinstall the Front Panel Board 66 http www tyan com 3 6 1 Front Panel Board Specifications Here shows the M1709G70 FPB Front Panel Board in details 7 2 9 1 USB Ports 5 LAN1 LAN2 LAN3 2 ID Button 6 Power On Off Button with LED 3 NMI Button 7 USB Connector 4 RESET Button 8 Front Panel Connector 18 5MMx44 2MM 4 Layer PCB One 2x15 pin header for front panel connector of motherboard and HDD backplane board Power On Off Button with LED Green ID LED Color Blue System Warning LED Amber System Fan Fail LED Red LAN1 LAN2 LAN3 Green RESET button ID button Power On Off button with LED NMI Button Connectors Push buttons gt gt gt gt gt gt gt gt gt gt 67 http www tyan com 3 6 2 Connector Pin Definition Front Panel Connector J3 Definition 11 2 2 Key 5 e TS FHD LANS_LED 7 8 HD LAN3 LED 9 10 5 4 12 SW 13 114 115 116 17 38 swt 719 120 Temp _ 21 22 EXT INT USB Connector J1 68 Definition VCC ID LED ID LED 5 5 FAULT1 SYS FAULT2 LAN1 LED LAN1 LED
17. S FAN2 4 pin Fan Connector SYS FANT 8 pin Power Connector PW3 6 Clear Button SW 1 PCIE Header PCIEx4 From CPU1 SAS HD1 right SAS HD2 left 8 LAN Port 2 LAN2 24 4 pin Fan Connector CPU1 FAN 9 ID LED 25 USB 2 0 Header USB2 HD1 10 4 pin Fan Connector SYS FAN5 26 PSMI Connector PSMI HD1 11 TYAN Module Header 27 24 pin Power Connector PW1 12 BMC LED 28 USB 3 0 Header USB3 HD1 13 COM Port COM2 29 TYPE A USB Header TYPEA USB3 14 Fan IO Header FAN HD1 30 4 in 1 Mini SAS Connector SSATAO 3 15 Front Panel Header FP_HD1 LAN2 31 PCH SATA SGPIO LED Header LAN LED HD1 Header SGPIO1 SATAO0 5 16 IPMB Connector IPMB HD1 32 4 in 1 Mini SAS Connector SATAO 3 Headers Jumpers a PSU Alert Disable Jumper 9 e MIC Card Jumper 3PHD 3 b BIOS Security Jumper 3PHD 4 f ID LED Button Header 2PHD 2 c ME Recovery Mode Jumper 3PHD 6 d Buzzer Disable Jumper 4PHD 1 1 OO gt cO g Chassis Intrusion Header 2PHD_1 Slots A PCI E Gen3 x8 MEZZ slot f CPU0 for DIMM G HII J LAN PCI E Gen3 x16 slot x16 link f CPU1 C PCI E Gen3 x16 slot x16 link f CPUO D PCI E Gen3 x4 slot x8 link ff CPU E PCI E Gen3 x4 slot x8 link f CPUO F PCI E Gne3 x8 MEZZ Slot f CPUO for SAS card CPU1 DIMM K L M N 30 http www tyan com Jumper Legend OPEN Jumper OFF Without jumper cover CLOSED Jumper ON With jumper cover 31
18. YAN GN70 B7086 GN70 252 420 11599 A C power cord L 1830mm EU type Power cord US 125V 18AWGX3C L 1800mm F CABLE ASSY SBU MINI SAS ABLE SHORT MINI SAS 36P HORT MINI SAS 36P L 800MM 83 http www tyan com Appendix III Fan and Temp Sensors This section aims to help readers identify the locations of some specific FAN and Temp Sensors on the motherboard A table of BIOS Temp sensor name explanation is also included for readers reference EN RT TTE L 69 NOTE The red dot indicates the sensor Fan and Temp Sensor Location Fan Sensor SYS FAN 1 SYS FAN 2 SYS FAN and SYS FAN 4 They detect the fan speed rpm 2 Temp Sensor SYS Air Inlet and M B Inlet Temp They detect the system temperature around NOTE The system temperature is measured in a scale defined by Intel not in Fahrenheit or Celsius 84 http www tyan com BIOS Temp Sensor Explanation Aptio Setup Utility Copyright 2014 American Megatrends Inc 85 Aptio Setup Utility Copyright C 2014 American Megatrends O Aptio Setup Utility Copyright C 2014 American Megatrends Inc 86 http www tyan com BIOS Temp Sensor Name Explanation CPUO DTS Temp Temperature of the CPUO Digital Temperature Sensor CPU1 DTS Temp Temperature of the CPU1 Digit
19. al Temperature Sensor CPUO PECI Value Temperature of the CPUO Platform Environment Control Interface CPU1 PECI Value Temperature of the CPU1 Platform Environment Control Interface SYS Air Inlet Temperature of the PCH Area SYS Air Outlet Temperature of the M B Air Inlet Area CPU1 MOS Area Temperature of the LAN Chip Area PCH Temp Temperature of GPUO CPUO DIMM Temperature of CPUO DIMM Slot CPUO DIMM A1 Temperature of CPUO DIMM A1 Slot CPUO DIMM BO Temperature of CPUO DIMM BO Slot CPUO DIMM B1 Temperature of CPUO DIMM B1 Slot CPUO DIMM CO Temperature of CPUO DIMM CO Slot CPUO DIMM C1 Temperature of CPUO DIMM C1 Slot CPUO DIMM DO Temperature of CPUO DIMM DO Slot CPUO DIMM D1 Temperature of CPUO DIMM D1 Slot CPU1 DIMM Temperature of CPU1 DIMM Slot CPU1 DIMM A1 Temperature of CPU1 DIMM A1 Slot CPU1 DIMM BO Temperature of CPU1 DIMM BO Slot CPU1 DIMM B1 Temperature of CPU1 DIMM B1 Slot CPU1 DIMM CO Temperature of CPU1 DIMM CO Slot CPU1 DIMM C1 Temperature of CPU1 DIMM C1 Slot CPU1 DIMM DO Temperature of CPU1 DIMM DO Slot CPU1 DIMM D1 Temperature of CPU1 DIMM D1 Slot BIOS FAN Sensor Name Explanation CPUO FAN Fan speed of CPUO FAN CPU1 FAN Fan speed of CPU1 FAN SYS FAN 1 Fan speed of SYS FAN 1 SYS FAN 2 Fan speed of SYS FAN 2 SYS FAN 3 Fan speed of SYS FAN 3 SYS FAN 4 Fan speed of SYS FAN 4 SYS FAN 5 Fan speed of SYS FAN 5 SYS FAN 6 Fan speed of SYS FAN 6 SYS FAN 7 Fan speed of SYS FAN 7 SYS FAN 8 Fan spee
20. ance in the rack Make sure the leveling jacks are extended to the floor 8 http www tyan com sure the full weight of the rack rests the leveling jacks Always load the rack from the bottom up Load the heaviest component in the rack first Make sure the rack is level and stable before pulling a component out of the rack Make sure only one component is extended at a time A rack might become unstable if more than one component is extended To avoid damage to the equipment The rack width and depth must allow for proper serviceability and cable management Ensure that there is adequate airflow in the rack Improper installation or restricted airflow can damage the equipment The rack cannot have solid or restricted airflow doors You must use a mesh door on the front and back of the rack or remove the doors to ensure adequate air flow to the system f you install the Model in a rack do not place equipment on top of the unit It will cause restricted airflow and might cause damage to the equipment Make sure the product is properly matted with the rails Products that are improperly matted with the rails might be unstable Verify that the AC power supply branch circuit that provides power to the rack is not overloaded This will reduce the risk of personal injury fire or damage to the equipment The total rack load should not exceed 80 percent of the branch circuit rating Consult th
21. d of SYS FAN 8 SYS FAN 9 Fan speed of SYS FAN 9 SYS FAN 10 Fan speed of SYS FAN 10 SYS FAN 11 Fan speed of SYS FAN 11 87 http www tyan com SYS FAN 12 Fan speed of SYS FAN 12 88 http www tyan com Appendix IV Technical Support If a problem arises with your system you should first turn to your dealer for direct support Your system has most likely been configured or designed by them and they should have the best idea of what hardware and software your system contains Hence they should be of the most assistance for you Furthermore if you purchased your system from a dealer near you take the system to them directly to have it serviced instead of attempting to do so yourself which can have expensive consequence If these options are not available for you then MITAC International Corporation can help Besides designing innovative and quality products for over a decade MITAC has continuously offered customers service beyond their expectations TYAN s website http www tyan com provides easy to access resources such as in depth Linux Online Support sections with downloadable Linux drivers and comprehensive compatibility reports for chassis memory and much more With all these convenient resources just a few keystrokes away users can easily find their latest software and operating system components to keep their systems running as powerful and productive as possible MiTAC also ranks high for its commitment to fast and friendly
22. details 2 x 2 pin 2 x 2 pin 2 x 2 pin 2 x 2 pin fan connector fan connector fan connector fan connector 161 1 c 2 x 2 pin 2 x 2 pin 1 x 4 pin 2 x 10 pin fan connector fan connector power connector barebeone fan connector J8 2 x 2 pin 2 x 2 pin 2 x 2 pin connector for S7015 MB fan connector fan connector 254 mm x 82 mm 4 layer PCB 2 1 4 Power Connector 8 2 2 Fan Connectors 1 2x10pin Barebone Fan Connector 1 2x2pin Connector for 7015 Integrated I O 3 8 2 Fan BP Board LED Definitions Without Fan 74 http www tyan com 3 8 3 Connector Pin Definitions Power Connector PW1 PW2 Definition Definition GND Barebone Fan Connector J8 Definition Definition FANINI 1 2 5 FANING FANN2 13 4 FANN3 75 16 X FANIN8 FANIN4 7 8 50 SIO FANIN2 Ke PWM SIO FANIN3 15 16 SMBUS 3V3 DATA SIO ae Ba SMBUS 3V3 VDD 3 3 AUX 20 MB PWM3 75 http www tyan com 3 9 Replacing the HDD Backplane Board Follow these instructions to replace the M1276GN70 12 8 HDD Backplane Board 1 Refer to Section 3 8 Replacing the Fan Backplane Board for how to remove the Fan Module Disconnect the power cables attached to the HDD BP Board s 5 NN 2 Unscrew the HDD BP Board Remove the HDD Board from the hook 3
23. e electrical authority having jurisdiction over your facility wiring and installation requirements Equipment Power Cords Use only the power cords and power supply units provided with your system The system might have one or more power cords Plug the power cord into a grounded earthed electrical outlet that is easily accessible at all times n all European electrical environments you must ground the Green Yellow tab on the power cord If you do not ground the Green Yellow tab it can cause an electrical shock due to high leakage currents Do not place objects on AC power cords or cables Arrange them so that no 9 http www tyan com one might accidentally step or trip over them Do not pull on a cord or cable When unplugging from the electrical outlet grasp the cord by the plug reduce the risk of electrical shock disconnect all power cords before servicing the appliance Equipment Batteries The system battery contains lithium manganese dioxide If the battery pack is not handled properly there is risk of fire and burns e Do not disassemble crush puncture short external contacts or dispose of the battery in fire or water Do not expose the battery to temperatures higher than 60 C 140 F The system battery is not replaceable If the battery is replaced by an incorrect type there is danger of explosion Replace the battery only with a spare designated for your product Do no
24. el PCI E Note Recommended TYAN OCP Card Pre install TYAN Riser Card Port Q ty Controller Connector SATA Controller Speed RAID Connector Controller SSATA Speed RAID Connector type Resolution Chipset USB COM VGA RJ 45 Chipset Voltage Temperature LED Others Onboard Chipset 4 Channels per CPU 6 PCI E Gen3 x16 slots w x8 link 1 OCP slot for Mezz Card 1 Proprietary slot for SAS Mezz Card 4 PCI E Gen3 x4 in MiniSAS HD for NVMe devices TYAN Proprietary M7062 B811 1T PCI E Gen3 x8 Broadcom 10GbE Mezz M7062 B810 2T PCI E Gen3 x8 Broadcom 10GbE Mezz Card M7076 X540 2T PCI E Gen3 x8 Intel 10GbE Mezz M7076 3108 8l PCI E Gen3 x8 LSI SAS 12G Mezz Card 7094 2308 81 PCI E Gen3 8 LSI SAS 6G Mezz Card 7076 3008 8 PCI E x8 LSI SAS 126 Mezz Card M7076 1350 PCI E Gen3 x8 Intel 2 GbE Mezz Card M7062 1599 1T PCI E Gen3 x8 Intel 10GbE Mezz Card M7062 1599 2T PCI E Gen3 x8 Intel 10GbE Mezz Card M7056 L24 3F M7056 R24 3F 3 GbE ports Intel 1350 AM2 Intel 1210 1 Mini SAS 4 ports 2 SATA totally support 6 ports Intel C612 6 0 Gb s RAID 0 1 10 5 Intel RST 1 Mini SAS 4 ports Intel C612 6 0 Gb s RAID 0 1 10 5 Intel RST only for 4 SATA devices D Sub 15 pin Up to 1920x1200 Aspeed AST2400 4 ports 2 at front 4 at rear 1 DB 9 COM port 1 D Sub 15 pin
25. ert PSU fail Normal System Fan System Fan Fail System Fan Fail Solid on U fail warning Normal ID LED Located zm Solid on Local and remote LAN1 Off line LAN2 Link Green LAN3 Activity Blinking PSU Redundancy 1 1 System Warning LED Indication System Warning LED Status O connected connected 2 PSU and 2 PSU AC cords are Amber solid on connected After system is powered on disconnect 1 PSU AC cord 2 PSU and 2 PSU AC cords are Amber solid on connected After system is powered on disconnect 1 PSU 25 http www tyan com Status Red HDD LED Behavior LED Status LED HDD Drive State No Driver Present or power disconnected No Activit Solid ON OFF Access Activity Blinking OFF HDD Drive Fail RAID Rebuild HDD Drive Locate Identifier Don t care Blinking 1Hz 26 http www tyan com 1 5 2 System Rear View me ee a C Power Supply LAN3 shared with IPMI 2 USB COM Port LAN2 left LAN1 right OCP card ports Reserved ID LED VGA Port 8 9 PCI E Slots 10 100 1000 Mbps LAN Link Activity LED Scheme left right Left LED Link Activity No tink OF 1Gbps Active Blinking Green NOTE Left and Right are viewed from the rear panel 27 http www tyan com Right LED Speed Solid Green Solid Green Solid Yellow Solid Yellow 1 1350 LAN ch
26. es mentioned earlier to install the second CPU and heatsink 43 http www tyan com 2 1 4 Installing the Memory Follow these instructions to install the memory modules onto the motherboard 1 Locate the memory slots on the motherboard 2 Press the memory slot locking levers in the direction of the arrows as shown in the following illustration 3 Align the memory module with the slot When inserted properly the memory slot locking levers lock automatically onto the indentations at the ends of the module Follow the recommended memory population table to install the other memory modules 44 http www tyan com Memory Population Option Table Recommended Memory Population Table Single CPU Single CPU Installed CPUO only Quantity of memory installed CPUO DIMM A0 CPUO DIMM A1 CPUO DIMM BO CPUO DIMM B1 CPUO DIMM CO CPUO DIMM C1 CPUO DIMM DO CPUO DIMM D1 lt Je 2 2 Je 2 NOTE 1 N indicates a populated DIMM slot 2 Use paired memory installation for max performance 3 Populate the same DIMM type in each channel specifically Use the same DIMM size Use the same of ranks per DIMM 45 http www tyan com Recommended Memory Population Table Dual CPU Dual CPU installed CPUO and CPU1 Quantity of memory installed CPUO DIMM AO CPUO DIMM A1 CPUO DIMM BO CPUO DIMM B1 CPUO DIMM CO CPUO DIMM C1 CPUO DIMM DO
27. essary 59 http www tyan com 3 Repeat the same procedures for the second Riser Card Bracket 4 zi L hin rim 6 RC 60 http www tyan com 3 4 2 PCI E Riser Cards Specification M7056 L24 3F riser card p ba i lt YAN a SID a uia 220 d 61 http www tyan com 3 4 3 Disconnecting All Motherboard Cables Before replacing the motherboard or certain components remove cables connected to the motherboard Follow these instructions to remove all cables 1 Disconnect the Mini SAS USB and 2x12pin power cables 2 Disconnect the PSMI and front panel cables 3 Disconnect the 2x4pin power cable http www tyan com 3 4 4 Removing the Motherboard After removing all of the aforementioned cables follow the instructions below to remove the motherboard from the chassis 1 Remove the heatsinks and processors if installed 2 Remove the nine screws securing the motherboard to the chassis 3 Carefully lift the motherboard from the chassis 63 http www tyan com 3 5 Replacing the Power Distribution Board Follow these instructions to replace the M1601T70 D PDB power distribution board 1 Disconnect all cables 2 Unscrew to replace a new power distribution board 64 http www tyan com 3 6 Replacing the Front Panel Board Follow these instructions to replace the M1709G70 FPB Front
28. http www tyan com 1 5 5 System Block Diagram 7086 Y Channel Channel RDIMM LRDIMM RDIMM LRDIMM 1600 1866 2133 MHz lt Socket R3 gt Socket R3 lt 1600 1866 2133 2 OCP 5 51 SAS CARD PCIE C PCIE E LAN1 5 PCIE Gen2 2 Intel i350 Gb LAN DMI Gen2 x4 4GB s PCIE_D PCIE B PCIE HD1 PCIE HD2 SSATA 6 0Gb s 4 PCH MINI SASO SSATA0 3 SSATA 6 0Gb s 6 Wellsburg C612 Yan MINI SEES 0 3 088201304 T 21 11111101 Debug Header Rear Front NCSI_1 PCIE Gen2 x1 JUR DDR3 Frame Buffer Memo C IS PCH Integrated CLK Smart Fan Controller Smart Fan Controler 227 Generator ASpeed Clock Buffer ICS ICS9ZX21901B Rear D Sub Connector D Sub Connector CC gt AST2400 COM Port os AST2300 32 http www tyan com 1 5 6 Internal View With Riser Card Brackets 3 5 2 5 HDD cage underneath SAS SATA HDD Backplane Board System Fan Unit Power Distribution Board PCI E Riser Card Bracket Power Supply underneath 33 http www tyan com Without Riser Card Brackets 217 1 TITE 4 504 3 5 2 5 HDD cage underneath SAS SATA HDD Backplane Board System Fan Unit Power Distribution Board Power Supply underneath 34 http www tyan com 35 http www tyan com 2 0 1 2 0 2 2 0 3 Chapter 2 Setting Up
29. ip is support on LAN1 and LAN2 can up to 1Gbps 2 1210 LAN chip is support on LAN3 can up to 1Gbps 3 Peripheral devices be plugged straight into any of these ports but software may be required to complete the installation ID LED LED Behavior Remark Color Normal Local and remote Located Solid on 28 http www tyan com 1 5 3 Motherboard 57086 Layout 32 3130 29 28 2726 2524 23 1 CECCO EE nIri I Iei dn ron B EIE CPUT DIMM BO CPUTSDIMM ET o Ze 8 Le 12 0000 eS c EE 13 14 17 This diagram is representative of the latest board revision available at the time of publishing The board you receive may not look exactly like the above diagram The DIMM slot numbers shown above can be used as a reference when reviewing the DIMM population guidelines shown later in the manual For the latest board revision please visit our web site at http www tyan com 29 http www tyan com 1 5 4 Jumpers amp Connectors Connectors 1 LAN port 3 IPMI and USB 3 0 ports 17 4 pin Fan Connector CPUO FAN 2 7 pin vertical SATA 3 0 Connector SATA5 upper SATA4 down 3 VGA Port COM Port 4 4 pin Fan Connector SYS FANA 5 ID Button SW2 8 pin Power Connector PW2 4 pin Fan Connector SYS FAN3 4 pin Fan Connector SY
30. ll components on to the motherboard including CPUs memory modules HDD and PCI E cards 2 1 1 Removing the Chassis Cover Follow these instructions to remove the GN70 B7086 chassis cover 1 Unscrew the rear top cover on the back side 2 Unscrew the front top cover and pull the latches aside to lift up the top cover 38 http www tyan com 3 Slide the rear top cover out 39 http www tyan com 2 1 2 Removing the Riser Card Brackets Follow these instructions to remove the PCI E Riser Card Brackets 1 Loose three thumb screws to release the PCI E Riser Card Brackets 40 http www tyan com 2 1 3 Installing the CPU and Heatsink Follow the steps below on installing CPUs and CPU heatsinks 1 of 16 20 yuu 5555 TUUS 1 T Pull the first and second levers slightly away from the socket and then push them to a fully open position 41 http www tyan com Push the CPU socket cover to fully open position Take the protection cap tra ee s ul i M a 2 A P n Place the CPU into the socket and make sure that the gold arrow is located in the right direction 42 5 Close the CPU socket cover and press the levers down to secure the CPU T UU Di 4 3 II 1111 t 7 e Repeat the procedur
31. m setup and technical support in case a problem arises with your system 9 http www tyan com Safety and Compliance Information Before installing and using TYAN GN70 B7086 take note of the following precautions Read all instructions carefully Do not place the unit on an unstable surface cart or stand Do not block the slots and opening on the unit which are provided for ventilation e Only use the power source indicated on the marking label If you are not sure contact the power company he unit uses a three wire ground cable which is equipped with a third pin to ground the unit and prevent electric shock Do not defeat the purpose of this pin If your outlet does not support this kind of plug contact your electrician to replace your obsolete outlet Do not place anything on the power cord Place the power cord where it will not be in the way of foot traffic Follow all warnings and cautions in this manual and on the unit case Do not push objects in the ventilation slots as they may touch high voltage components and result in shock and damage to the components When replacing parts ensure that you use parts specified by the manufacturer When service or repairs have been done perform routine safety checks to verify that the system is operating correctly Avoid using the system near water in direct sunlight or near a heating device Cover the unit when not in use 6 http www tyan
32. mate controlled 7 http www tyan com Ensure that the voltage and frequency of your power source match the voltage and frequency inscribed on the electrical rating label of the equipment Do not install the system in or near a plenum air duct radiator or heat register Never use the product in a wet location Equipment Chassis Do not block or cover the openings to the system Never push objects of any kind through openings in the equipment Dangerous voltages might be present Conductive foreign objects can produce a short circuit and cause fire electric shock or damage to your equipment Lift equipment using both hands and with your knees bent Equipment Racks To avoid injury or damage to the equipment Observe local occupational health and safety requirements and guidelines for manual materials handling Do not attempt to move a rack by yourself a minimum of two people are needed to move a rack Do not attempt to move a fully loaded rack Remove equipment from the rack before moving it Do not attempt to move a rack on an incline that is greater than 10 degrees from the horizontal Make sure the rack is properly secured to the floor or ceiling Make sure the stabilizing feet are attached to the rack if it is a single rack installation Make sure racks are coupled together if it is a multiple rack installation Make sure the rack is level and stable before installing an appli
33. nt Barebone Manual Installation CD Intel C612 6 0 Gb s RAID 0 1 10 5 Intel RST only for 4 SATA devices D Sub 15 pin Up to 1920x1200 Aspeed AST2400 4 ports 2 at front 4 at rear 1 DB 9 COM port 1 D Sub 15 pin port 3 ports 1 port shared with IPMI Aspeed AST2400 Monitors voltage for CPU memory chipset amp power supply Monitors temperature for CPU amp memory amp system environment Over temperature warning indicator Fan amp PSU fail LED indicator Chassis intrusion detection Watchdog timer support Onboard Aspeed AST2400 IPMI 2 0 compliant baseboard management controller BMC Supports storage over IP and remote platform flash USB 2 0 virtual hub 24 bit high quality video compression 10 100 Mb s MAC interface AMI 16MB User configurable H W monitoring SMBIOS 2 7 PnP Wake on LAN PXE boot support 3 0 ACPI sleeping states 51 54 55 Please refer to our Intel OS supported list Class A Yes 1022 55 F 95 F 40 C 70 40 F 158 F 90 non condensing at 35 C Yes 1 GN70 B7086 Barebone 1 Web User s manual 1 Quick Installation Guide 1 TYAN installation CD 20 http www tyan com 1 4 Standard Parts List This section describes GN70 B7086 package contents and accessories Open the box carefully and ensure that all components are present and undamaged The product should arrive packaged as illustrated below 1 4 1 Box Con
34. orm Factor Gross Weight Chassis Model Dimension D x W x H Motherboard Board Dimension Buttons LEDs I O Ports Q ty HDD backplane support Supported HDD Interface FAN Type 2U Rackmount 25 kg GN70 27 56 x 17 72 x 3 43 700 x 450 x 87mm S7086GM3NRE EATX 12 13 305x330mm 1 RST 1 ID 1 PWR w LED 1 PWR 1 ID 1 Warning 3 LAN 2 USB ports 2 5 or 3 5 Hot Swap 8 SAS SATA 6 0Gb s 2 Mini SAS 8ports w SATA 6Gb s SAS 12Gb s 4 6cm fans ERP1U 18 http www tyan com Processor Chipset Memory Expansion Slots LAN Storage Efficiency Redundancy Serviceability Input Range Frequency Output Watts Supported CPU Series Socket Type Q ty Thermal Design Power TDP wattage System Bus PCH Supported DIMM Qty DIMM Type Speed Capacity Memory channel PCI E Note Recommended TYAN OCP Card Pre install TYAN Riser Card Port Q ty Controller Connector SATA Controller Speed RAID 80 plus gold 1 54 Hot swap 100 127V AC 10A 200 240V AC 5A 50 60 Hertz 770 Watts Intel Xeon Processor E5 2600 v3 series processors LGA2011 2 Max up to 145W Up to 9 6 8 0 6 4 GT s with Intel QuickPath Interconnect support Intel C612 8 8 DIMM slots DDR4 2133 1866 1600 LRDIMM DDR4 2133 1600 LRDIMM 30 DDR4 2133 1600 Up to 512GB RDIMM 1 024GB LRDIMM 2 048GB LRDIMM 3DS
35. ot limited to the following TYAN is a trademark of MiTAC International Corporation Intel is a trademark of Intel Corporation AMIBIOS and combinations thereof are trademarks of AMI Technologies Microsoft Windows are trademarks of Microsoft Corporation PE AT and PS 2 are trademarks of IBM Corporation Winbond is a trademark of Winbond Electronics Corporation 3 http www tyan com FCC Declaration Notice for the USA E Compliance Information Statement Declaration of w Conformity Procedure DoC FCC Part 15 This device complies with part 15 of the FCC Rules This device complies with Part 15 of the FCC Rules Operation is subject to the following conditions This device must not cause harmful interference This device must accept any interference received including interference that may cause undesirable operation This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which
36. port 3 ports 1 port shared with IPMI Aspeed AST2400 Monitors voltage for CPU memory chipset amp power supply Monitors temperature for CPU amp memory amp system environment Over temperature warning indicator Fan amp PSU fail LED indicator Chassis intrusion detection Watchdog timer support Onboard Aspeed AST2400 17 http www tyan com Management BIOS Operating System Regulation Operating Environment RoHS Package Contains AST2400 IPMI Feature AST2400 iKVM Feature Brand ROM size Feature OS supported list FCC DoC CE DoC Operating Temp Non operating Temp In Non operating Humidity RoHS 6 6 Compliant Barebone Manual Installation CD IPMI 2 0 compliant baseboard management controller BMC Supports storage over IP and remote platform flash USB 2 0 virtual hub 24 bit high quality video compression 10 100 Mb s MAC interface AMI 16MB User configurable H W monitoring SMBIOS 2 7 PnP Wake on LAN PXE boot support 3 0 ACPI sleeping states 51 54 55 Please refer to our Intel OS supported list Class A Yes CG 50 F gt F 40 C 70 C 40 F 158 F 90 non condensing at 35 C Yes 1 GN70 B7086 Barebone 1 Web User s manual 1 Quick Installation Guide 1 TYAN installation CD TYAN GN70B7086 B7086G70V8HR System Front Panel External Drive Bay System Cooling Configuration Power Supply F
37. r injury to yourself Ground yourself properly before removing the top cover of the system Unplug the power from the power supply and then touch a safely grounded object to release static charge i e power supply case If available wear a grounded wrist strap Alternatively discharge any static electricity by touching the bare metal chassis of the unit case or the bare metal body of any other grounded appliance Avoid touching motherboard components IC chips connectors memory modules and leads The motherboard is pre installed in the system When removing the motherboard always place it on a grounded anti static surface until you are ready to reinstall it e X Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do so Do not flex or stress circuit boards Leave all components inside the static proof packaging that they ship with until they are ready for installation After replacing optional devices make sure all screws springs or other small parts are in place and are not left loose inside the case Metallic parts or metal flakes can cause electrical shorts CAUTION Please note that the following illustrations may not look exactly like the rackmount server you purchased Therefore the illustrations should be held for your reference only 37 http www tyan com 21 Installing Motherboard Components This section describes how to insta
38. t attempt to recharge the battery Dispose of used batteries according to the instructions of the manufacturer Do not dispose of batteries with the general household waste To forward them to recycling or proper disposal use the public collection system or return them to TYAN your authorized TYAN partner or their agents Equipment Modifications Do not make mechanical modifications to the system TYAN is not responsible for the regulatory compliance of TYAN equipment that has been modified Equipment Repairs and Servicing The installation of internal options and routine maintenance and service of this product should be performed by individuals who are knowledgeable about the procedures precautions and hazards associated with equipment containing hazardous energy levels Do not exceed the level of repair specified in the procedures in the product documentation Improper repairs can create a safety hazard Allow the product to cool before removing covers and touching internal 10 http www tyan com components Remove all watches rings or loose jewelry when working before removing covers and touching internal components Do not use conductive tools that could bridge live parts Use gloves when you remove or replace system components they can become hot to the touch e Ifthe product sustains damage requiring service disconnect the product from the AC electrical outlet and refer servicing to an authorized
39. tents 21 Description 2U chassis 8 hot swap HDD bays TYAN S7086 system board pre installed 1 1 Redundant Power Supply 770W DELTA DPS 770GB C 4 System fan M1601T70 D PDB Power Distribution Board pre installed HDD BP M1276G70 BP12E 8 M1276G70 BP 12 8 pre installed M1709G70 FPB pre installed M7056 L24 3F riser card pre installed M7056 R24 3F riser card pre installed M1806G70 FB pre installed http www tyan com 1 4 2 Accessories If any items are missing or appear damaged contact your retailer or browse to TYAN s website for service http www tyan com The web site also provides information of other products as well as FAQs compatibility lists BIOS settings etc Motherboard Drive CD Heatsink x 2 Rail Kit AC Power Cord 250V Europe x 2 Barebone Manual 22 http www tyan com Addendum for China Use Only 23 http www tyan com 1 5 About the Product The following views show you the product 1 5 1 System Front View ID RST 0 AO HDD Sequence HDDO HDD3 HDD1 HDD4 HDD6 HDD2 HDD5 HDD7 Ears 3 5 2 5 HDD bays USB Ports ID Button NMI Button RESET Button LAN1 LAN2 LAN3 ID LED System Fan Fail LED System Warning LED Power On OFF Button with LED 24 http www tyan com LED Definitions Color Normal System All BMC Amber Warning LED Warning Solid on warning PSU al
40. teps described earlier in reverse to remove the chassis from the rack NOTE To avoid injury it is strongly recommended that at least two people lift the TYAN 70 7086 to hook on or unhook from the rails 57 http www tyan com Chapter 3 Replacing Pre Installed Components 3 1 Introduction This chapter explains how to replace the pre installed components including the 57086 Motherboard M1709G70 FPB Front Panel Board PCI E Riser Card M1276G70 BP12E 8 M1276G70 BP12 8 SATA SAS HDD Board System Fan and Power Supply Unit etc 3 2 Disassembly Flowchart The following flowchart outlines the disassembly procedure Front Components Front Panel Board HDD Backplane Rear Components PCI E Riser Card Motherboard CPU Heatsink Air Duct PCI E Card Motherboard 58 http www tyan com 3 3 Removing the Cover Before replacing any parts you must remove the chassis cover Follow Section 2 1 1 Removing the Chassis Cover page 38 to remove the cover of the GN70 B7086 3 4 Replacing Motherboard Components Follow these instructions to replace motherboard components including the motherboard 3 4 1 Replacing PCI E Riser Card Cards The GN70 B7086 has two pre installed PCI Ex16 riser cards Follow the instructions below to disassemble the M7056 L24 3F and M7056 R24 3F PCI E riser cards 1 Unscrew to take out the PCI E card 2 Unscrew the M7056 R24 3F riser card to replace a new one if nec
41. tion easier we suggest that you remove all HDD trays before you insert the chassis to the rack 1 Position the rear of the sliding rail to the rear side of the rack Make sure the mid point of the rail align with the anchor point marked in red US 4 53 http www tyan com 2 Repeat the same procedures for the front end of the Front Push the locking latch to secure the rail to the rack Repeat the same procedures for the other rail Left Right 54 http www tyan com 4 Slide the inner rail to its full length Note that to slide to its full length push the locking tab of the rail upward and then the rail can slide freely There are three holes on each rail which are used to hook and secure the chassis 5 Align the studs on the chassis with the holes on the rails and make sure the chassis is securely hooked Oe va cece HJ 69929969 e 2929249209 a e tenan 55 http www tyan com 6 Push the chassis back into the rack 7 The installation is now complete 56 http www tyan com 2 2 2 Removing the Server from Rack Follow these instructions to remove the TYAN GN70 B7086 from an industry standard 19 rack 1 Push the ears to pull the chassis forward 3 1 2 Push forward the locking tabs on both rails to unhook the chassis from the rails 9 Follow the s
42. yan com 1 3 Features TYAN GN70B7086 B7086G70V6E2HR Form Factor 2U Rackmount Gross Weight 25 kg Chassis Model GN70 D x W X 57 56 x 17 72 x 3 43 700 x 450 x 87mm Motherboard S7086GM3NRE Board Dimension EATX 12 x13 305x330mm Buttons 1 RST 1 ID 1 PWR w LED Front Panel LEDs 1 PWR 1 ID 1 Warning 3 LAN I O Ports 2 USB ports Type Q ty 2 5 or 3 5 Hot Swap 8 External Drive SATA 6Gb s SAS 12Gb s Supported HDD 2 Mini SAS HD for 8ports NVMe devices PCI E x4 Interface single System Cooling FAN 4 6cm fans Configuration Type ERP1U Efficiency 80 plus gold Redundancy 1 1 Power Supply Serviceability Hot swap Input Range 100 127V AC 10A 200 240V AC 5A Frequency 50 60 Hertz Output Watts 770 Watts 2 Intel Xeon Processor E5 2600 v3 series processors Socket Q ty LGA2011 2 Thermal Design Processor Power TDP Max up to 145W wattage Svstem Bus Up to 9 6 8 0 6 4 GT s with Intel QuickPath y Interconnect QPI support Chipset PCH Intel C612 Supported DIMM slots Qty DDR4 2133 1866 1600 LRDIMM DDR4 memory DIMM Type Speed 3133 1600 LRDIMM 30 DDR4 2133 1600 Up to 512GB 1 024GB LRDIMM 2 048GB Capacity LRDIMM 3DS Follow latest Intel DDR4 Memory POR 16 http www tyan com Expansion Slots LAN Storage Graphic I O Ports System Monitoring Server Memory chann