Home

FISOCommander Bus Veloce Edition

image

Contents

1. eccceeseeeteeeeeeseceeeeeeeeaeeeaeeeeaeeeaeeceeesceeeseaeesaeeseaeesaeeseseeeeeseaeeeaeeees 4 Data Acquisition Station Optional Package isseire aaea ardea aa a a Nade E CaN 5 FISOCommander Bus Veloce Edition Bus windows description 11 s 1cccsecccsneceseensserseanencesseenssernesnenenses 6 MET O1 E E TAEA ATE NAE EAEE TE E A T EET AE AAAA A 6 Chassis ConfiQurations ssiri Ene EEEE EEE EAEE EAEE Sa E ATRE 7 SAI N srasni g A iiaei deaa 8 Gage Configuration ssn AL A A a a A ai iaaa A aa iia 9 Analog Output and Acquisition Configuration 10 RS 232 ACQUISITION ceeeceeteeeeeeteetteeeetteeeee em Fa Analog Output Card Optional a13 Analog Output Card Configuration weds NormallChartMode cia dr lat 14 FISOCommander Bus Veloce Edition Veloce windows COSCHIPLION 2 ccseccsseeenssertssnecsseenssserestenens 15 Main Wi NAOUN 2 a ee eet 2015 Chassis Configuration s e 16 Analog Output and Acquisition Configuration 18 Analog Output Card Optional eee 20 Normal Chart Mode 22 Fast Ghart Mode e a siria ar E Taa Ta a a e a a e aE A Ao Taa E e aa Ee aA a EAE a E aE aaa AAEE EE ASE 23 Operation Dasis iia ii a A AEA KRAE A A ph a i ee ee 24 How to replace a sensor wi 24 ACQUISITION 0 eee ee cece eeeeeeteeeeeeenees wi 24 How to make an acquisition 1 24 How to increase decrease the rate wi 24 How to do averaging oococcccocccocccnnnananccnancnananannccn
2. M Bus 2 Model SORES Graph serie color E ie 43 Hardware Configuration Co National Instruments I Veloce module bay association nia Y El System L 2 Gauge eS r Acquisition Configuration Normal Chart Mode r File Configuration 7 AO amp Acquisition Config Ase File Format Ma AS 232 Acquisition Acquisition Speed fio Hz he Column Separator fr ab S Analog Output Card Bee Contig Acquisition Duration foo Sec y Decimal Separator Dot Normal Chart Mode Y Use graph File Recovery r Acquisition Configuration Fast Plot Mode iar daome Filename C Ask for Filename Acquisition Speed fio kHz e C Don t use file Acquisition Duration jo Sec y Dutput Folder wa IV Use graph C Program Files FISOS oft FISOCommander Bu AO Card Info 15 This box provides information from the National Instrument Card If you are using several acquisition cards make sure to select the proper one that corresponds to the Veloce conditioner Four 4 different National Instruments cards are available PCI 6034E PCI 6035E PCI 6071E PCMCIA DAQCard Al 16E 4 Acquisition Configuration Normal Mode 16 The normal mode offer real time display up to 10 kHz It is also where the user must specify the Acquisition Duration For all acquisition a text file is generated and at his convenience the user may disable the graph plotted at the computer screen Acquisition Configur
3. Gauge Scale fi 0 0 Speed fs00Hz Average RS 232 Acquisition swe Downloading finished Refresh El 14 This window shows the actual configuration information Press the Download button to download the data from the buffer To save the downloaded data in csv file press Save button To return to the previous window press Back button The download time may take up to 5 minutes For measurement verification and faster download simply reduce the number of data collected in the previous windows O Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual 12 Analog Output Card Optional The analog acquisition features integrated in FISOCommander Bus Veloce Edition are available only if you purchased the Data Acquisition Station optional package If you purchased the Data Acquisition Station the following section will be preconfigured at factory onto the laptop provided If the software ever needs to be registered again simply click on the button on the top right of the window to unlock the Analog Output Card functionality A registration window will appear allowing you to enter your registration number provided with your package Analog Out FISOCommander Bus Veloce 3 11 Veloce 1 43 Hardware Config E System Contig A AO amp Acquisition Config e 43 Analog Output Card Contig Normal Char
4. Module serial number Hardware version Software version Last date of calibration 6 Itis also possible to export calibration parameters in text file for advanced use 17 Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Analog Output and Acquisition Configuration FISOCommander Bus Veloce AO amp Acquisition Config D Veloce 1 Gi Hardware Config Configuration analog output and acquisition E System Config lt Analog output gt amp AO amp Acquisition Config nm unit my unit nm45000 mv Average amp 0 Analog Output Card Sensitivity Scale Span ms Bay 1 001 000 Calcul 00005 000 01000 Null Reset 0001 000 Bay 9 001 000 Calcul 00005 000 01000 Null Reset 0001 000 Bay ai 001 000 Calcul 00005 000 01000 Null Reset 0001 000 Bay 4 001 000 Calcul 00000500 10000 Null Reset 0000 005 Calculf Null Reset Calcul Null Reset cacal Null Reset cacai Aull Heset Refresh SENSITIVITY 7 Enter your sensor s sensitivity in nm unit Note that the default sensitivity is 1 000 nm unit CALCUL GAGE FACTOR 8 Enter in this option only if you have access to the gage factor of your transducer The screen will automatically calculate the sensitivity using your gage factor a Enter gage factor 7 digits b Click on Calcul button to display the appropriate sens
5. Acquisition contig gt m Units Units sec sec Auto 4cq Contig Scale Zero value Average Rate 4 Normal Chart Mode Fast Plot Mode 8 Bus 2 53 Hardware Configuration E System Gauge 3 AO amp Acquisition Config Bay 5 00001 0 00000 000 1000 Hz 00 001 000000 001 Ma AS 232 Acquisition S Analog Output Card Contig Normal Chart Mode a ee amp al SCALE AND ZERO VALUE 9 Set the desired analog output scale factor in mV physical unit 10 Set the desired analog output zero value in physical unit SPEED AVERAGE AND RATE 11 Set the analog output acquisition speed average and rate values Note that the average cannot be smaller than one time the speed and that the rate cannot be smaller than the average For more information refer to the Bus System user s manual AUTO ACQ 12 The Auto Acq checkmark is activated by default When the user modifies a parameter in this window the Bus System will stop the acquisition calculate its internal parameters and restart automatically the acquisition This processus can be long if you want to modify more than one of the parameter Therefore you could disable the auto acquisition during the time you do your modification and reactivate it after O Copyright 2003 FISO Technologies inc 10 MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual RS 232 Acquisition FISOCommander Bus Veloce RS 232 Acquisiti
6. FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual FISOCommander Bus Veloce Edition Bus windows description FISOCommander Bus Veloce Edition is compatible only with eprom version of Bus System from 3 42 upward Previous version of eprom should use the BUS Link software Eprom upgrade is possible by returning the system to the factory Please contact our technical support for assistance FISOCommander Bus Veloce Edition software is divided into different windows In the coming pages we made screenshots of each window and added a description of the different functions available in order to facilitate the user understanding Main window FISOCommander Bus Veloce I Bus 1 5 Hardware Configuration System Gauge E AO amp Acquisition Config BB AS 232 Acquisition Analog Output Card Config Normal Chart Mode 8 1 Veloce 2 57 Hardware Config System Contig R AO amp Acquisition Config a Analog Output Card Contig Normal Chart Mode Fast Plot Mode Configuration Com Port Com Port fi y Conditioner model Bus y Add Com Port Conditioner model 1 Bus Delete 2 Veloce Delete All 1 In the main window of FISOCommander Bus Veloce Edition select your computer Communication Port used to establish the serial link RS 232 2 Precise the conditioner model Bus and click Add Copyright 2003 FISO Technologies inc 6 MAN 00035 R10
7. eloce Edition E x Lee veloce diagnostic s0 791 6 OK 1 813 7 OK s2 842 2 kkkbkkbkbkkk pp 2 QH okk s0 9486 4 OK s1 12541 7 OK s2 11279 1 OK kokbok ED Oy deeesisieiotoioioieistoksietetstoktetototok s0 3958 3 OK s1 5049 7 OK 52 4392 5 OK Compare results with diagnostic chart provided in your conditioner user manual 19 O Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Analog Output Card Optional The analog acquisition features integrated in FISOCommander Bus Veloce Edition are available only if you purchased the Data Acquisition Station optional package If you purchased the Data Acquisition Station the following section will be preconfigured at factory onto the laptop provided If the software ever needs to be registered again simply click on the button on the top right of the window to unlock the Analog Output Card functionality A registration window will appear that allowing you to enter your registration number provided with your package FISOCommander Bus Veloce S nm Veloce 1 C Hardware Config Analog Card amp Channel Configuration E System Config I i 57 AO amp Acquisition Config AO Card Info Channel Configuration amp Analog Output Card No Device fi y evious 1 Next gt gt Config OxBCESEB Normal Chart Mode SerialNo JOxBCE8EB Y Channel Enable Fast Plot Mode l E
8. Edition software go to the AO amp Acquisition Configuration At the gage factor box type in the new gage factor 3 Before making an acquisition it is a good habit to verify that the gage factor assigned to each module is the proper one Also make sure that the acquisition space required for saving data does not exceed the computer capacity Acquisition How to make an acquisition Connect a sensor Make sure the Gage Factor is the proper one If required set your Analog Output Scale and Average Rate Select the mode desired and type in the acquisition duration and the sampling rate desired Go in the Slow mode and press Start Data are saved in a text file format on your hard drive Browse your hard drive to retrieve the file POON IN How to increase decrease the rate 1 Gointhe AO 8 Acquisition Configuration 2 In the Rate box type in a new value The Rate value is expressed is seconds lt represents the time between two outputs How to do averaging 1 Averaging feature may be helpful to eliminate noise and improve system accuracy The averaging amp rate is one parameter and should be set to the best compromise How to open a text file and analyze it with Excel 1 Load Excel program 2 Inthe File menu select Open 3 At the open window select the file type txt 4 Select the folder containing the text file Copyright 2003 FISO Technologies inc 24 MAN 00035 R10 FISOCommander BusVeloce
9. Edition Software User s Manual Troubleshooting How to verify your RS 232 cable RS 232 cables are rarely the source of a problem but most of the time they are confused or replaced by null modem cable Conditioner Computer link requires RS 232 standard cable Modem Conditioner link requires RS 232 Null Modem cable If it is a standard RS 232 cable what you need Pin 2 is linked to Pin 2 Pin 3 is linked to Pin 3 RS 232 Null Modem cable connections what you should avoid Pin 2 is linked to Pin 3 Pin 3 is linked to Pin 2 How to verify the RS 232 port Occasionally RS 232 ports are subjected to unpredictable defects The quickest way to verify the port is via a test with another conditioner or equipment that requires the use of the RS 232 port Re Installation procedure Laptop package recovery steps 1 This procedure will format the computer hard drive Data and program installed on the computer will be deleted Prior to proceed to this operation make sure that you have a copy of all important files 2 Insert the Recovery CD ROM 3 Reboot your computer FISO Technologies package re installation steps 1 From the CD FISO_SOFT provided by FISO install the National Instrument driver for acquisition card Once completed turn off your computer and install the National Instrument data acquisition card in your computer Restart your computer Windows should recognize the card 3 From the CD FISO_SOFT provided by FISO insta
10. FISOCommander Bus Veloce Edition Software Operating Manual MAN 00035R11 If the equipment described herein bears the C symbol the said equipment complies with the applicable European Union Directive and Standards mentioned in the Declaration of Conformity SAFETY INFORMATION The following safety instructions must be observed whenever the instrument is operated Failure to comply with any of these instructions or with any precaution or warning contained in the conditioner Operating Manual is in direct violation of the standards of design manufacture and intended use of the conditioner In no case will FISO Technologies Inc be liable to the buyer or any third parties for any consequential or indirect damage witch is caused by product failure malfunction or any other problem DISCLAIMER Information published in this manual is believed to be accurate and reliable However FISO Technologies assumes no responsibility for the use of such information FISO Technologies reserves the right to make revisions or changes to any parts of this manual or to the software described herein at any time without obligation to notify of these changes WARRANTY INFORMATION FISO Technologies warrants that the software sold has been designed in good workmanlike and proper manner that it will perform according to the specifications if used in compliance with the guidelines provided that when shipped it will be fully functi
11. FISOCommander BusVeloce Edition Software User s Manual Chassis configuration FISOCommander Bus Veloce Hardware Configuration 5 1 Veloce 1 43 Hardware Config r System Config Chassis configuration 5 AQ amp Acquisition Config ne O 1 Analog Output Card Please select module position Bus in chassis Contig Normal Chart Mode Fast Plot Mode Bay 1 Bay 2 Bay 3 r Bay 4 8 m Bus 2 News 2 Mana 75 None S Hardere Configuration Ee Veloce ESRI C Be C Bus System E Gauge Cove Succesful configuration PEA as 7 AO amp Acquisition Config BB AS 232 Acquisition Bay8 8 Analog Output Card Contig None Normal Chart Mode C Bus C Bus Vel q C vel Test module connection 3 Make the configuration following the number of modules and their position From left to right modules are labeled as position 1 to 8 4 When completed click on Test module connection The window Successful configuration will appear If the window does not appear please refer to the Troubleshooting section at the end of this manual 7 O Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual System Configuration FISOCommander Bus Veloce 8 8 Veloce 1 57 Hardware Config System Contig 7 AO amp Acquisition Config a Analog Output Card Contig Normal Chart Mode Fast Plot Mode 2 M Bus 2 59 Hardware Configu
12. SIC Physic ISIC ASIC gt Nul dul j Na Diagnostic Diagnostic Diagnostic Diagnostic Diagnostic Diagnostic Diagnostic Normal Chart Mode alalaMlalalal PEE REEEE DANE ANIA Ebert Add Nul Diagnostic Refresh x ASIC SELECT GAGE 6 For each module select the proper gage You can also add or delete a gage from the gage list GAGE OFFSET 7 The Gage Offset section is used to define a zero value to a relative sensor If the user wants the sensor s actual exposure to become the zero position in physical unit simply click on Null button If the user wants to force a reading to the actual sensor condition simply click Physic and type in the value physical unit For advanced users if desired an offset in internal units nanometers may be directly entered in the type in box by the user 8 For each module you could verify the gage diagnostic For more information on the diagnosis feature see the Bus System user s manual section 4 1 9 Copyright 2003 FISO Technologies irc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Analog Output and Acquisition Configuration FISOCommander Bus Veloce AO amp Acquisition Config mD Veloce 1 43 Hardware Config System Contig A AO amp Acquisition Config a 43 Analog Output Card Analog aquisition configuration Analog output gt lt
13. Veloce Edition Software User s Manual Fast Chart Mode FISOCommander Bus eloce Edition 3 IOl x Fast Plot Mode As I l 0 2 0 6 0 8 1 0 4 1000 data 0 1 sec Data acquisition Fast Chart Mode 23 Due to the higher speed the visual plotting is generated faster to ensure reliability of the system Also make sure to start the acquisition just before the event Take note that long acquisition at high speed rate generates heavy file on your hard drive For example a 200 kHz rate acquisition of 10 seconds long will generate a 2 5 Mo file Note that for example Microsoft Excel software cannot open file of more than about 65000 data Examples Duration 1 minutes Al Card PCI 6035E FAST Graph mode Channel s Speed Temporary file Text file Post Process duration 1 200kHz 47 meg 262 meg 3 min 20 sec 2 100kHz 47 meg 192 meg 2 min 11 sec 4 50kHz 47 meg 159 meg 1 min 37 sec 10 20kHz 47 meg 146 meg 1 min 21 sec 16 10kHz 38 meg 122 meg 58 sec 23 Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Operation basis How to replace a sensor 1 Remove your transducer from its box and connect it to the selected channel To establish a good connection between the conditioner and the transducer follow the key way on the transducer connector and make sure to lock it to the conditioner 2 In FISOCommander Bus Veloce
14. ation Fast Mode 17 This box is similar to the normal mode The main exception is that the acquisition speed available is larger The acquisition can be performed at a speed of 10 kHz 200 kHz Due to the higher sampling rate the graph plotting parameters are different in order to ensure system reliability Copyright 2003 FISO Technologies inc 20 MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Channel Configuration 18 This box contains all the settings for the real time display function available Slow or Fast mode For each channel the user may assign a precise color According to specific needs one specific channel can be enabled or disabled by adding and removing the checkmark When checked the Veloce module bay association will recall the corresponding setting to save module configuration in the text file File Configuration 19 This box contains all the settings for generating a text file In the text file the data will display in columns Each column contains data corresponding to one channel sensor For easiest export to Excel we recommend to separate the columns by a tab and to separate the decimals with a dot This configuration makes the export to Excel software easy to perform 20 During the acquisition the system generates a binary file that is unreadable Its name is the selected file name except that it finishes by a for example Filename txt When the acquisition is fin
15. conditioner manual FISO Technologies highly suggest its customers to read the conditioner manual for a better understanding of their whole system System requirements Minimum requirements Microsoft Windows 95 98 2000NT or XP Monitor with a 800 X 600 resolution 233 MHz Intel Pentium Minimum 64 megabytes RAM 20 MB hard disk space System recommended Microsoft Windows 2000NT 300 MHz Intel Pentium 11M 128 megabytes RAM 40 MB hard disk space System recommended for high speed analog acquisition Microsoft Windows 2000NT 1 5 GHz Intel Pentium IV M 256 megabytes RAM 500 MB hard disk space O Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Data Acquisition Station Optional Package The Data Acquisition Station is an extension package that monitors and displays the high speed BUS and Veloce analog output and gives an easy way to quickly generate an Excel file from the tests performed Depending if you purchased this extension or not some software modules may not be accessible RS 232 Computer with PCMCIA or PCI NI DAQ card Bus Veloce System Analog output BNC 2090 Acquisition Module card Ribbon cable BNC Cable Quick Start Make the connections as described above Turn on your computer In the program files launch the FISOCommander Bus Veloce Edition software Make a test O Copyright 2003
16. derstanding Main window FISOCommander Bus Veloce s M Bus 1 EJ Hardware Configuration System Gauge EJ AO amp Acquisition Config a AS 232 Acquisition Analog Output Card Contig Normal Chart Mode 8 1 Veloce 2 57 Hardware Config System Config 7 AO amp Acquisition Config a Analog Output Card Config Normal Chart Mode Fast Plot Mode Configuration Com Port Com Port 2 y Conditioner model Veloce y Com Port Conditioner model 1 Bus Delete 2 Veloce Delete All 1 In the main window of FISOCommander Bus Veloce Edition select your computer Communication Port used to establish the serial link RS 232 2 Precise the conditioner model Veloce and click Add 15 Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Chassis configuration FISOCommander Bus Veloce Hardware Config 8 3 Veloce 1 3 Hardware Config E System Config Chassis configuration 57 AO amp Acquisition Config Sauer e i e 17 Analog Output Card Please select module position Veloce in chassis Contig Normal Chart Mode Fast Plot Mode Bay 1 Bay 2 Bay 3 r Bay 4 _ 8 m Bus 2 O Nees Oo Kana None Gi Hardware Coniguaton 50comancer tus mer fy j jus JUS System il E Gauge Succesful configuration C Veloce E AO amp Acquisition Config BB AS 232 Acquisition Analog Output Card Q C
17. e communication fails during the acquisition the generated file is not post processed and its name finishes by a this indicates that the file is still in binary The user can then launch the post processing by clicking the button file recovery to obtain the text file for the acquisition 20 The text file generated can be saved under a fixed name or under an automated name generator If you select fixed filename the software will ask a filename once the user press start for acquisition The file will be saved in the folder specified by the user The automatic file generator prevents to overwrite on an existing file The filename will be generated from the date and time of the acquisition Normal Chart Mode FISOCommander Bus eloce Edition E ioj xj Normal Chart Mode i 10 8 6 4 2 0 2 4 6 8 10 Normal Chart Mode This visual plotting is generated to ensure normal process of the acquisition For advanced graphic generation we recommend to export data in spreadsheet software Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual 14 FiSOCommander Bus Veloce Edition Veloce windows description FISOCommanaer Bus Veloce Edition software is divided into different windows In the coming pages we made screenshots of each window and added a description of the different functions available in order to facilitate the user un
18. ished or when the user clicks on stop button in the graph window the generated file is post processed all information are converted in ASCII characters and the binary file is deleted In the case where the software communication fails during the acquisition the generated file is not post processed and its name finishes by a This indicates that the file is still in binary The user can then launch the post processing by clicking the button file recovery to obtain the text file for the acquisition 21 The text file generated can be saved under a fixed name or under an automated name generator If you select fixed filename the software will ask a filename once the user presses start for acquisition The file will be saved in the folder specified by the user The automatic file generator prevents to overwrite on an existing file The filename will be generated from the date and time of the acquisition 21 Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Normal Chart Mode FISOCommander Bus eloce Edition Pi ES Normal Chart Mode i 10 8 6 4 2 0 2 4 6 8 10 Normal Chart Mode 22 This visual plotting is generated to ensure normal process of the acquisition For advanced graphic generation we recommend to export data in spreadsheet software Copyright 2003 FISO Technologies inc 22 MAN 00035 R10 FISOCommander Bus
19. itivity or on Apply to set the sensitivity of the current module ig Sensivity calcul x Gauge Factor 0001 000 Sensitivity 001 000 nm Z unit Apply Exit Copyright 2003 FISO Technologies inc 18 MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Note With temperature and refractive index gage the system is unable to calculate the sensitivity In these cases the user must perform his own calibration using a reference sensitivity of 1 000 nm units ANALOG OUTPUT SCALE mV Unit 9 Set the analog output scale factor desired SPAN 10 According to the Analog Output Scale setting described above the software will automatically calculate a new SPAN factor for the conditioner The user does not have access to change this setting NULL 11 Press the null buttons for zeroing the module analog output RESET 12 Press the reset buttons for zeroing your fiber optic sensors Front plate RESET The front plate RESET activates the lamp re calibration and then zeroes the gage Software RESET The software RESET simply zeroes the gage which is recommended for multiple routine test AVERAGE 13 Set the speed and average value Note that the speed and average features are controlled via one parameter The slower the Rate is the more Averaging the system will perform DIAGNOSTIC 14 Read signal diagnostic for current Veloce module FISOCommander Bus
20. ll the FISOCommander Bus Veloce Edition software 4 Link your computer communication port to the conditioner serial connector using the provided RS 232 cable 5 Reboot your computer and scroll in the program file to launch the application 6 Link the computer to the BNC junction box and from the junction box to the conditioner Analog Output 7 Connect your sensor to the conditioner Sensor input 25 O Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Frequently asked questions Q Why is it impossible to install the software Make sure to uninstall previous software before to install a new one Q Why is the software unable to detect the conditioner or a module Verify if the conditioner is well connected to the computer with a standard RS 232 cable supplied with your conditioner Pay attention not to use a RS 232 Null Modem cable required for modem application Make sure that each module is well connected Q Why is Excel unable to open the text file If there is a at the end of the file name click on File Recovery in the Config window to launch the post processing of the file Also note that spreadsheet software like Excel are limited to about 65000 data or 150 Mo files Q What is FISO1000 or 0001000 gage factor FISO1000 cannot be deleted it is a default gage factor from FISO which provide measurements in nanomete
21. no wi 24 How to open a text file and analyze it with Excel c cssesssessessssssssessesseessessssussneescssssussussnsarsessesesesssssussseeseesessessteeseeseeseenees 24 TFOUDICSNOOUING A A sued ov Aa A ra a Aaa a a a a a Ea Ea a er e r Aaaa Eaa aeaa 25 How to verify you RS 232 cable wi 25 How to verify the RS 232 port 12d Re Installation Procedure messan A deutcheuedtesdaeey tesa A ltda dd 25 Frequently asked QUESTIONS 1ccseccccseccseensscenssnenceanancusennsnennsanancaseensasenssnensuaansaseoesseeessuaaesaseenssensenenseasanense 26 POTOSI ENA TSOE REPS 27 R S 232 Syntax amp Command S A sate ns aa a seconds arar aa ra dons DA aapear aa does shsbbe cvsnchtazdecbsapedbadtss 27 Welcome in FISOCommander Bus Veloce Edition Introduction FISOCommander Bus Veloce Edition software is designed to help the developers in their daily objectives Combined with the Bus or the Veloce conditioner it provides an easier visualization of the functions and ensures a quick access to all your parameters setting The FISOCommander Bus Veloce Edition software will be of great help to ensure a continuous progress in your tests or developments Dynamic sampling of the data Analog output configuration Rate and Average configuration Export function for external data analysis Save the data in spreadsheet software like Microsoft Excel or Corel Quattro format for further analysis This software manual is an extension of your
22. on S mu Veloce 1 ee sonha Direct acquisition ances Acquisition information k coria Speed Average Rate Nb data Appx delay Contig j 2 Normal Chart Mode Fast Plot Mode M Bus 2 53 Hardware Configuration El System Disp i Disp Display Display a 1000Hz 00 001 000000 001 4096 4 096 sec J AO amp Acquisition Config Bay 5 J AS 232 Acquisition a 43 Analog Output Card Contig Normal Chart Mode Display Display Display ATT Display i 13 This window displays the acquisition speed average and rate for each module Set the number of desired data for the acquisition Note that the number of data is limited to 4096 The data are stored in a circular memory so the system will store the number of data desired in a continuous way until the acquisition is stopped The approximate delay for the acquisition is shown To start the acquisition press the Start button To display the results press the Display button 11 Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual FISOCommander Bus Veloce 2 M Bus 1 57 Hardware Configuration System E Gauge AO amp Acquisition Config BB AS 232 Acquisition Analog Output Card e M Bus 2 59 Hardware Configuration System E Gauge 7 AO amp Acquisition Config AS 232 Acquisition E Analog Output Card Download BUS Data m Configuration NoModule
23. onal free from any defects in either workmanship or material and that for a period of one year from the date of delivery we will repair or replace without cost any part that may prove to be defective All computers and computer components acquisition card known as per the terminology computer station provided by FISO Technologies are warranted for the same period and conditions as their respective original manufacturer warranty In case of repair requirement items must be returned to FISO Technologies factory location with the RMA authorization FISO Technologies support will be limited to the applications originally provided FISO Technologies is not responsible for the lost of data and softwares installed by the customer Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual TABLE OF CONTENTS Welcome in FISOCommander Bus Veloce Edition s cs sssecsereeseesceeccecserccsecerserseescsereeseesernsesees 4 introduction arera A A A S 4 System rEQUIFEMENLS cccccccceccsccscssccscsecsecsecsesscsscsesssssesaesesessessessesscsscsessessesassassessassassassesasassassassessassesasseseesaesassasseseesaesaasaecassesaesatcateaseaeans 4 MINIMUM QUIM SA sxcessencwelsevenessccuaatvubbes cscudsecedsvousbtescaddubuesttassedaneasueteeciscendueesSursunddeccessieeeds 4 System recommended A a OT e 4 System recommended for high speed analog ACQUISITION
24. onfig None Normal Chart Mode aus C Bus C Bus C Bus gt Bay 8 Veloce Veloce Veloce Veloce Test module connection N 3 Make the configuration according to the number of modules and their position From left to right modules are labeled as position 1 to 8 4 When completed click on Test module connection The window Successful configuration will appear and then you will be able to access to the other configuration windows If the window does not appear please refer to the Troubleshooting section at the end of this manual Copyright 2003 FISO Technologies inc 16 MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual System Configuration FISOCommander Bus Veloce 88 Veloce 1 57 Hardware Config 3 System Config 7 AO amp Acquisition Config f er Analog Output Card Serial Number Hardware Version Software Version Calibration Date Contig Bay 1 O2VE120 Weloce50 200 2 41 2 2003 01 15 10 29 Export parameter s E oa ga Bay2 02VE126 Veloce50 2 00 2 41 2 2002 11 25 11 45 Export parameter 8 m Bus 2 Ba 53 Hardware Configuration System Bay 4 System Config Configuration System Parameters jarameter 2 Gauge Saaz A AO amp Acquisition Config a Jarameter BB AS 232 Acquisition 6 Analog Output Card Contig Normal Chart Mode jarameter 5 The system s configuration window provides information on the module
25. ration SJ System 2 Gauge EJ AO amp Acquisition Config BB AS 232 Acquisition 8 Analog Dutput Card Contig Normal Chart Mode Configuration System Parameters Serial Number Hardware Version Software Version Units 02801065 1KV2T 3 42 1 Ud 4 International x maj Eset Open Open Reset Open Reset Open Heset Open Reset Open Reset Open Reset Open Heset PR EREERES PEE ELEL Refresh 5 The system s configuration window provides information on the module Serial Number Hardware Version Software Version Type of units international or imperial This window also allows the user to turn on off the lamp of each module The reset buttons are used to reinitialize the memory content of the desired Bus module to the default state values Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual g Gage Configuration FISOCommander Bus Veloce 8 8 Veloce 1 4 Hardware Config System Contig 7 AO amp Acquisition Config a 43 Analog Output Card Contig Normal Chart Mode Fast Plot Mode M Bus 2 53 Hardware Configuration El System 3 Gauge J AO amp Acquisition Config Ma AS 232 Acquisition amp 09 Analog Output Card Contig Configuration transducers for BUS module Select gauge Add Add Add Add Add Add 0001000 Add Gauge offset ASIC SIC aysic W
26. rs internal unit Copyright 2003 FISO Technologies inc 26 MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual Reference Reflection Property of light As opposed to transmission the light makes its way back from where it is coming RS 232 Serial communication establish for electronic communication The RS 232 port is normally a standard device on any computer RS 232 Syntax amp Commands RS 232 commands are listed at the end of your conditioner user s manual 27 Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual
27. t Mode Fast Plot Mode M Bus 2 59 Hardware Configuration El System Gauge 57 AO amp Acquisition Config Ma AS 232 Acquisition a 43 Analog Output Card Config Normal Chart Mode ut Card Configuration Analog Card amp Channel Configuration 7 40 Card Info No Device hoo x SerialNo OxBCESEB Model PCI 6035E Co National Instruments Channel Configuration Y Channel Enable Graph serie color AD me a Edit Bus module bay association n a E r Acquisition Configuration Normal Chart Mode Acquisition Speed fio Hz bd Acquisition Duration joo Sec y Y Use graph m File Configuration File Format Column Separator Decimal Separator Dot File Recovery Automatic Filename C Ask for Filename C Don t use file Output Folder C Program Files FISOS oft FISOCommander Bu File name AO Card Info 15 This box provides information from the National Instrument Card If you are using several acquisition cards make sure to select the proper one that corresponds to the Bus System Four 4 different National Instruments cards are available PCI 6034E PCI 6035E PCI 6071E PCMCIA DAQCard Al 16E 4 Acquisition Configuration Normal Mode 16 The normal mode offers real time display up to 10 kHz note that the Bus System is limited to 1 kHz It is also where the user must specify the Acquisition Duration For all acquisition a te
28. xt file is generated and at his convenience the user may disable the graph plotted at the computer screen Channel Configuration 17 This box contains all the settings for the real time display function available For each channel the user may assign a precise color According to specific needs one specific channel can be enabled or disabled by adding and removing the checkmark When checked the Bus module bay association will recall the corresponding setting to save module configuration in the text file 13 Copyright 2003 FISO Technologies inc MAN 00035 R10 FISOCommander BusVeloce Edition Software User s Manual File Configuration 18 This box contains all the settings for generating a text file In the text file the data will display in columns Each column contains data corresponding to one channel sensor For easiest export to Excel we recommend to separate the columns by a tab and to separate the decimals with a dot This configuration makes the export to Excel software easy to perform 19 During the acquisition the system generates a binary file that is unreadable lts name is the selected file name excepted that it finishes by a for example Filename txt When the acquisition is finished or when the user clicks on stop button in the graph window the generated file is post processed all information are converted in ascii characters and the binary file is deleted In the case where the softwar