FX3S-30M*/E*-2AD HARDWARE MANUAL

image

Contents

1. Manual Basic amp Applied STL SFC programming and f ss 09R517 Instruction Edition devices MELSEC QIL F Structured SH 080782 aia peda ae Programming Manual MODET CODE a uired to create structured Fundamentals 13JW06 q programs FXCPU Structured JY997D26001 Devices parameters etc Programming Manual MODEL CODE provided in structured Device amp Common 09R925 projects of GX Works2 FXCPU Structured JY997D34701 Sequence instructions Programming Manual MODEL CODE provided in structured Basic amp Applied Instruction 09R926 projects of GX Works2 FXCPU Structured JY997D34801 Application functions Programming Manual MODEL CODE provided in structured Application Functions 09R927 projects of GX Works2 FX Series User s Manual JY997D16901 ater ba cpa Data Communication MODEL CODE olo ol A i b Edition 09R715 P y RS instructions FX2N 232F Manual name Description Describes specifications for FX3S FX3G FX3GC FX3uU JY997D16701 analog control and FX3UC Series User s Manual MODEL CODE programming methods for Analog Control Edition 09R619 FX3S FX3G FX3GC F X3uU FX3UC Series PLC Explains the specifications FX3S FX3G FX3GC FX3uU JY997D16801 for positioning control of FX3UC Series User s Manual MODEL CODE FX3S FX3G FX3GC F X3U Positioning Control Edition 09R620 FX3UC Series and programming procedures Certification of UL cUL standards Please consult with Mitsubishi Elec
2. FX3G 8AV BD from June 1st 2009 FX3U 3A ADP FX3U ENET ADP FX3S CNV ADP FX3S 30MR ES 2AD FX3S 30MT ES 2AD FX3S 30MT ESS 2AD FX3G 4EX BD FX3G 2EYT BD FX3G 485 BD RJ FX3S 5DM from February ist 2012 from March 1st 2013 from September 1st 2013 from September 1st 2014 Standard Remark EN61131 2 2007 Programmable controllers Equipment requirements and tests Compliance with all relevant aspects of the standard EMI e Radiated Emission e Conducted Emission EMS e Radiated electromagnetic field e Fast transient burst e Electrostatic discharge e High energy surge e Voltage drops and interruptions e Conducted RF e Power frequency magnetic field Requirement for Compliance with LVD directive The following products have shown compliance through direct testing of the identified standards below and design analysis through the creation of a technical construction file to the European Directive for Low Voltage 2006 95 EC when used as directed by the appropriate documentation Type Programmable Controller Open Type Equipment Models MELSEC FX3s series manufactured from September 1st 2013 FX3S 30MR ES 2AD FX3S 30MT ES 2AD FX3S 30MT ESS 2AD Standard Remark EN61131 2 2007 Programmable controllers Equipment requirements and tests The equipment has been assessed as a component for fitting in a suitable enclosure which meets the requirements of EN61131 2 2007 Caution for c
3. Flashing when a program error occurs Red Lights when a CPU error occurs 7 Output display LEDs red 8 The year and month of production 9 Model name abbreviation 10 DIN rail mounting hooks When the top covers are open 1 No Name 1 Optional equipment connector 2 Power supply terminal Input X terminals 3 Analog input terminal block 4 RUN STOP switch 5 Peripheral device connecting connector USB 6 Peripheral device connecting connector RS 422 7 Service power supply terminal Output Y terminals 3 Terminal cover 9 Optional equipment connecting screw holes Right side Genuine product certification label IL The authentication label for authorized products is affixed to the right side of the product to avoid to be forged Products that do not have the genuine product certification label or nameplate are not covered by the warranty 2 2 External dimensions and weight 2 64 5 mounting holes Unit mm inches MSE FXes W1 Mounting hole pitches 8 0 32 75 2 96 Mounting hole pitches W1 W mm inches MASS Weight Mogername mm inches Direct mounting kg Ibs hole pitches FX3S 30MD EL 2AD 100 3 94 92 3 63 eae Installation e 35 mm wide DIN rail or Direct screw mounting M4x2 3 Installation generic specifications As
4. V AC power is supplied to the main unit 100 to 240 V AC Breaker Main unit eee ee MC Power supply for loads connected to PLC output terminals 4 3 Grounding Ground the PLC as stated below e Perform class D grounding Grounding resistance 100 Q or less e Ground the PLC independently if possible If it cannot be grounded independently ground it jointly as shown below PLC Other Other Other equipment equipment equipment Q Q O Independent grounding Common grounding Best condition Not allowed Shared grounding Good condition e Use ground wires thicker than AWG14 2 mm e Position the grounding point as close to the PLC as possible to decrease the length of the ground wire 4 4 Input specifications and external wiring For details refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 4 4 1 Input specifications Item Specification Number of input points 16 points Input connecting type Fixed terminal block M3 screw Sink Source 24 V DC 10 10 X000 to X007 3 3 kQ X010 to X017 4 3 KQ X000 to X007 7 mA 24 VDC Input signal current X010 to X017 5 mA 24 V DC ON input sensitivity X000 to X007 4 5 mA or more current X010 to X017 3 5 mA or more OFF input sensitivity current 1 5 mA or less Input form Input signal voltage Input impedance Input response time Approx 10 ms No voltage contact input NPN open collector transist
5. for installation of the special adapters and expansion boards refer to the following manual Refer to FX3S Series User s Manual Hardware Edition INSTALLATION PRECAUTIONS CAUTION e Use the product within the generic environment specifications described in section 3 1 of this manual Never use the product in areas with excessive dust oily smoke conductive dusts corrosive gas salt air Cl2 H2S SO2 or NO2 flammable gas vibration or impacts or expose it to high temperature condensation or rain and wind If the product is used in such conditions electric shock fire malfunctions deterioration or damage may occur Do not touch the conductive parts of the product directly Doing so may cause device failure or malfunctions Install the product securely using a DIN rail or mounting screws Install the product on a flat surface If the mounting surface is rough undue force will be applied to the PC board thereby causing nonconformities When drilling screw holes or wiring make sure cutting or wire debris do not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions Be sure to remove the dust proof sheet from the PLC s ventilation port when installation work is completed Failure to do so may cause fire equipment failures or malfunctions Connect the peripheral device cables securely to their designated connectors Loose connections may cause malfunctions Turn off the power to t
6. or less lt Reference gt ee Pressure Terminal Manufacturer Type No Certification Bonding Tool FV1 25 B3A UL Listed YA 1 JST FV2 FV2 MS3 e When two wires are connected to one terminal J S T Mfg Co Ltd 3 2 0 13 n Terminal Solderless 6 2 mm 0 24 EEC soro aii or less gt oe 6 3 mm 0 25 or more 3 2 0 13 6 2 mm 0 24 Terminal or less 6 3 mm 0 25 or more lt Reference gt Pressure Bonding Tool YA 1 JST Terminal Manufacturer Type No Certification FV1 25 B3A UL Listed J S T Mfg Co Ltd 4 2 Power supply specifications and example of external wiring For details refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 4 2 1 Power supply specifications Item Specification Supply voltage 100 to 240 V AC Allowable supply voltage range 85 to 264 V AC Rated frequency 50 60 Hz Allowable instantaneous power failure time Operation can be continued upon occurrence of instantaneous power failure for 10 ms or less 250V 1A 15 A max 5 ms or less 100 V AC 28 A max 5 ms or less 200 V AC Power fuse Rush current Power consumption 21 W 24 V DC service power supply 400 mA This item shows values when all 24 V DC service power supplies are used in the maximum configuration connectable to the main unit and includes the input current 5 or 7 mA per point 4 2 2 Example of external wiring 100 to 240
7. to 10 V DC Input resistance 115 7 kQ Absolute maximum input 0 5 V 15 V Digital output 10 bits binary D8270 The digital value of CH1 is stored D8271 The digital value of CH2 is stored 10 mV 10 V 1000 1 0 100 mV for 10 V full scale when ambient temperature is 25 5 C 2 0 200 mV for 10 V full scale when ambient temperature is 0 to 55 C 180 us The data will be updated at every scan time of the PLC Device allocation Resolution Total accuracy A D conversion time 1020 1000 7 I 0 gt 10V 10 2V Analog input Input characteristics yndyno jey 61q Insulation method No insulation between each channel or the PLC 0 point This number is not related to the maximum number of input output points of the PLC Occupied points 6 2 2 Example of analog input Grounding E VOi chO represents the channel number Use the 2 core shielded twisted pair cable for the analog input lines and separate the analog input lines from other power lines or inductive lines 2 Make sure to short circuit the VL and V terminals when ch is not used 6 2 3 Analog input terminal block layouts This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems i
8. 1 5KVAC for 1 min 5 kV AC for 1 min withstand voltage 2 500 V AC for 1 min Between each terminals and ground terminal 2 Insulation 5 MQ or more by resistance 2 500 V DC megger Class D grounding grounding resistance 100 Q or less Grounding lt Common grounding with a heavy electrical system is not allowed gt Working Free from corrosive or flammable gas and excessive conductive atmosphere dusts Working 4 altitude 2000m 1 The criterion is shown in IEC61131 2 2 Dielectric withstand voltage and insulation resistance are shown in the following table Dielectric Insulation eraio strength resistance E Terminals of main units Between power supply terminal AC 1 5 kV AC power and ground terminal for 1 min Between input terminal 24 V DC and 500 V AC ground terminal for 1min 5 MQ or more by 500 V DC Between output terminal relay and 1 5 kV AC megger ground terminal for 1 min Between output terminal transistor and 500 V AC ground terminal for 1 min Main unit analog input terminal and Not allowed Not allowed ground terminal E Terminals of expansion boards special adapters Between terminal of expansion board except FX3G 4EX BD and FX3G 2EYT Not allowed Not allowed BD and ground terminal Between FX3G 4EX BD input terminal 24 V DC and ground terminal Between FX3G 2EYT BD output 500 V AC terminal transistor and ground terminal for 1 min 5 MQ or more by 500 V DC megger Bet
9. Side B JAPANESE B ENGLISH MITSUBISHI ELECTRIC PROGRAMMABLE CONTROLLERS MELSEE IF FX3s 30ML EL 2AD HARDWARE MANUAL EX Manual Number JY997D51701 This manual describes the part names dimensions mounting cabling and specifications of the product Before use read this manual and the manuals of all relevant products fully to acquire proficiency in handling and operating the product Make sure to learn all the product information safety information and precautions Store this manual in a safe place so that it can be taken out and read whenever necessary Always forward it to the end user Registration Phillips is a registered trademark of Phillips Screw Company The company and product names described in this manual are registered trademarks or the trademarks of their respective companies Remon DT Effective April 2015 Specifications are subject to change without notice 2013 MITSUBISHI ELECTRIC CORPORATION Safety Precaution Read these precautions before use This manual classifies the safety precautions into two categories and ZACAUTION Indicates that incorrect handling may cause hazardous N WARNING conditions resulting in death or severe injury Indicates that incorrect handling may cause hazardous CAUTION conditions resulting in medium or slight personal injury or physical damage Depending on the circumstances procedures indicated by CAUTION may also cause severe injury It is imp
10. Where possible users should run analog cables separately Good cable shielding should be used When terminating the shield at Earth ensure that no earth loops are accidentally created When reading analog values EMC accuracy can be improved by averaging the readings This can be achieved either through functions on the analog products or through a user s program in the FX3S Series PLC main unit Incorporated Items Check if the following product and items are included in the package Included Items Dust proof protection sheet Manuals Japanese English FX3S 30MR ES 2AD FX3S 30MT ES 2AD FX3S 30MT ESS 2AD 1 sheet 1 manual 1 Feature FX3S 30ML EL 2AD is a product based on FX3S PLC with built in analog input in place of variable analog potentiometers Refer to the following figure Specifications other than the built in analog input are the same as FX3S PLC For details refer to FX3S Series User s Manual Hardware Edition For details on the built in analog input refer to Chapter 6 Variable analog potentiometer Analog input terminal block 3 2 Outline 2 1 Part names 3 10 9 8 No Name 1 Top cover 2 Terminal names 3 Terminal block covers 4 Input display LEDs red 5 Peripheral device connecting connector cover Operation status display LEDs On while power is on the PLC 6 On while the PLC is running Red
11. ar ka ria CRIMPFOX 6 a EU or CRIMPFOX 6T F 1 Old model name CRIMPFOX ZA 3 2 Old model name CRIMPFOX UD 6 e Stranded wire solid wire e Stick terminal with insulating sleeve Termination of Insulating sleeve Contact area cable end Crimp area 5mm 0 19 2 to 2 5mm 0 07 to 0 09 No of wire per terminal Caulking tool 10 5 to 12 mm 0 41 to 0 47 When using a stick terminal with an insulating sleeve choose a wire with proper cable sheath referring to the above outside dimensions otherwise the wire cannot be inserted easily Tighten the screws to a torque of 0 22 to 0 25 Nem Do not tighten terminal screws with a torque outside the above mentioned range Failure to do so may cause equipment failures or malfunctions 3 Tool For tightening the terminal use a commercially available small screwdriver having a straight form that is not widened toward the end as shown right 2 5 mm Caution 0 03 If the diameter of screwdriver grip is too small tightening torque will not be able to be achieved To achieve the appropriate tightening torque shown in the table above use the following screwdriver or appropriate replacement grip diameter approximately 25 mm 0 98 Manufacturer Phoenix Contact Co Ltd With straight tip Model name SZS 0 4x2 5 6 2 Analog input specifications and external wiring 6 2 1 Analog input performance specifications Item Input specification Analog input range 0
12. he PLC before attaching or detaching the following devices Failure to do so may cause device failures or malfunctions Peripheral devices display module expansion boards special adapters and memory cassette e When a dust proof sheet is supplied with units keep the sheet applied to the ventilation slits during installation and wiring work e To prevent temperature rise do not install the PLC on a floor a ceiling or a vertical surface Install it horizontally on a wall as shown in section 3 2 e Keep a space of 50 mm 1 97 or more between the unit main body and another device or structure part A Install the unit as far away as possible from high voltage lines high voltage devices and power equipment A 3 1 Generic specifications Item Specification Ambient 0 to 55 C 32 to 131 F when operating and temperature 25 to 75 C 13 to 167 F when stored Ambient humidity 5 to 95 RH no condensation when operating Half amplitude mm Sweep Count Pop When 10 to 57 ea 0 035 forX Y Z Vibration installed 10 times Frequency Acceleration m s each When 10 to 57 0 075 direction installed directly 57 to 150 ae Shock 147 m s Acceleration Action time 11 ms 3 times by half sine resistance pulse in each direction X Y and Z Noise By noise simulator at noise voltage of 1 000 Vp p noise width of 1 resistance us rise time of 1 ns and period of 30 to 100 Hz Dielectric
13. hield of the analog input output cable at one point on the signal receiving side However do not use common grounding with heavy electrical systems Make sure to properly wire to the terminal block European type in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product The disposal size of the cable end should follow the dimensions described in the manual Tightening torque should follow the specifications in the manual Twist the end of strand wire and make sure that there are no loose wires Do not solder plate the electric wire ends Do not connect more than the specified number of wires or electric wires of unspecified size Affix the electric wires so that neither the terminal block nor the connected parts are directly stressed 6 1 Analog input terminal block European type 1 Wire size Wiring to analog device should use wire from following table Wire size Stranded wire PLE coh plastic sleeve 1 0 14 to 1 5 mm 0 14 to 1 0 mm 0 25 to 0 5 mm AWG26 to 16 AWG26 to 16 AWG24 to 20 2 0 14 to 0 5 mm 0 14 to 0 2 mm g AWG26 to 20 AWG26 to 24 2 Termination Strip the coating of strand wire and twist the cable core before connecting it or strip the coating of single wire before connecting it An alternative connection is to use a ferrule with insulating sleeve Manufacturer Mo
14. mergency stop circuit a protection circuit an interlock circuit for opposite movements such as normal vs reverse rotation and an interlock circuit to prevent damage to the equipment at the upper and lower positioning limits 2 Note that when the PLC CPU detects an error such as a watchdog timer error during self diagnosis all outputs are turned off Also when an error that cannot be detected by the PLC CPU occurs in an input output control block output control may be disabled External circuits and mechanisms should be designed to ensure safe machinery operation in such a case 3 If an overload of the 24 V DC service power supply occurs the voltage automatically drops inputs in the PLC are disabled and all outputs are turned off External circuits and mechanisms should be designed to ensure safe machinery operation in such a case 4 Note that when an error occurs in a relay or transistor output device the output could be held either on or off For output signals that may lead to serious accidents external circuits and mechanisms should be designed to ensure safe machinery operation in such a case DESIGN PRECAUTIONS CAUTION e Do not bundle the control line together with or lay it close to the main circuit or power line As a guideline lay the control line at least 100 mm 3 94 or more away from the main circuit or power line Noise may cause malfunctions e Install module so that excessive force will not be a
15. nvolving industrial property rights which may occur as a result of using the contents noted in this manual Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi opportunity loss or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi Electric e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN
16. ompliance with EC Directive Installation in Enclosure Programmable logic controllers are open type devices that must be installed and used within conductive control boxes Please use the FX3S Series programmable logic controllers while installed in conductive shielded control boxes Please secure the control box lid to the control box for conduction Installation within a control box greatly affects the safety of the system and aids in shielding noise from the programmable logic controller Analog input output The analog input output have been found to be compliant to the European standards in the aforesaid manual and directive However for the very best performance from what are in fact delicate measuring and controlled output devices Mitsubishi Electric would like to make the following points As analog devices are sensitive by nature their use should be considered carefully For users of proprietary cables integral with sensors or actuators these users should follow those manufacturers installation requirements Mitsubishi Electric recommends that shielded cables be used If NO other EMC protection is provided users may experience temporary loss or accuracy between 10 10 in very heavy industrial areas However Mitsubishi Electric suggests that adequate EMC precautions be followed for the users complete control system Sensitive analog cables should not be laid in the same trunking or cable conduit as high voltage cabling
17. or No voltage contact input PNP open collector transistor Input circuit insulation Photocoupler insulation Input signal form LED on panel lights when niput oRErANON diS plisy photocoupler is driven 4 4 2 Examples of input wiring 1 Sink input type 2 Source input type Class D grounding ois D A ronn bee eee eee bee eee eee 3 wire type sensor 3 wire type sensor 4 4 3 Instructions for connecting input devices As for the details of Instructions for connecting input devices refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 4 5 Relay output specifications and example of external wiring For details refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 4 5 1 Relay output specifications Item Specification Number of output points 14 points Output connecting type Fixed terminal block M3 screw Output form Relay 30 V DC or less External power supply 240 V AC or less Resistance load 2 A point 2 Max load Inductive load 80 vA Min load 5 V DC 2 mA reference value Item Specification Open circuit leakage current OFF ON Response time ONOFF Approx 10 ms Output circuit insulation Mechanical insulation LED on panel lights when power is Output operation display applied to relay coil 1 250 V AC or less when the unit does not comply with CE UL or cUL standards 2 The total load cu
18. ortant to follow all precautions for personal safety STARTUP AND MAINTENANCE PRECAUTIONS WARNING e Do not touch any terminal while the PLC s power is on Doing so may cause electric shock or malfunctions e Before cleaning or retightening terminals cut off all phases of the power supply externally Failure to do so may cause electric shock Before modifying or disrupting the program in operation or running the PLC carefully read through this manual and the associated manuals and ensure the safety of the operation An operation error may damage the machinery or cause accidents JY997D51701D STARTUP AND MAINTENANCE PRECAUTIONS CAUTION e Turn off the power to the PLC before attaching or detaching the memory cassette If the memory cassette is attached or detached while the PLC s power is on the data in the memory may be destroyed or the memory cassette may be damaged Do not disassemble or modify the PLC Doing so may cause fire equipment failures or malfunctions For repair contact your local Mitsubishi Electric representative Turn off the power to the PLC before connecting or disconnecting any connection cable Failure to do so may cause equipment failures or malfunctions Turn off the power to the PLC before attaching or detaching the following devices Failure to do so may cause equipment failures or malfunctions Peripheral devices display module expansion boards special adapters and memor
19. pplied to peripheral device connectors Failure to do so may result in wire damage breakage or PLC failure e Even if the AC power supply causes an instantaneous power failure for less than 10 ms the PLC can continue to operate e If a long time power failure or an abnormal voltage drop occurs the PLC stops and output is turned off When the power supply is restored it will automatically restart when the RUN input is on WIRING PRECAUTIONS WARNING e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product WIRING PRECAUTIONS CAUTION e Connect the AC power supply wiring to the dedicated terminals described in this manual If an AC power supply is connected to a DC input output terminal or DC power supply terminal the PLC will burn out Noise resistance may be lower when the L and N wires of an AC power supply are not wired correctly Please wire using the correct polarity Do not wire vacant terminals externally Doing so may damage the product Perform class D grounding grounding resistance 100 or less to the grounding terminal on the main unit with a wire 2 mm or thicker Do not use common grounding with heavy electrical systems refer to section 4 3 When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may ca
20. pretation of partition The partition of the output terminals see following figure indicates the range of the output connected to the same common Example FX3s 30MT ES 2AD Output terminal como cow Partition 6 Built in analog specifications and wiring For details on the built in analog input specifications and wiring refer to following manual Refer to FX3S Series User s Manual Hardware Edition WIRING PRECAUTIONS WARNING e Make sure to cut off all phases of the power supply externally before attempting installation or wiring work Failure to do so may cause electric shock or damage to the product WIRING PRECAUTIONS CAUTION e When drilling screw holes or wiring make sure cutting or wire debris does not enter the ventilation slits Failure to do so may cause fire equipment failures or malfunctions WIRING PRECAUTIONS CAUTION e Make sure to observe the following precautions in order to prevent any damage to the machinery or accidents due to abnormal data written to the PLC under the influence of noise 1 Do not bundle the power line or shield of the analog input output cable together with or lay it close to the main circuit high voltage line or load line Otherwise noise disturbance and or surge induction are likely to take place As a guideline lay the control line at least 100 mm 3 94 or more away from the main circuit high voltage line or load line 2 Ground the s
21. r more Y000 Y001 Response OFF gt ON 5 to 24 V DC time ON OFF 0 2 ms or less 200 mA or more Y002 to Y015 at 24 V DC Output circuit insulation Photocoupler insulation LED on panel lights when Output operation diSplay photocoupler is driven The total load current of resistance loads per common terminal should be the following value 1 output point common terminal 0 5 A or less 4 output points common terminal 0 8 A or less As for the number of outputs per common terminal refer to Chapter 5 interpretation of partition and the following manual Refer to FX3S Series User s Manual Hardware Edition 2 The total of inductive loads per common terminal should be the following value 1 output point common terminal 12 W or less 24 V DC 4 output points common terminal 19 2 W or less 24 V DC As for the number of outputs per common terminal refer to Chapter 5 interpretation of partition and the following manual Refer to FX3S Series User s Manual Hardware Edition 4 6 2 External wiring of transistor output 1 External wiring of sink output type 4 6 3 Cautions in external wiring As for the details of cautions in external wiring refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 5 Terminal block layouts For details on the terminal block layout refer to the following manual Refer to FX3S Series User s Manual Hardware Edition Inter
22. rrent of resistance loads per common terminal should be the following value 1 output point common terminal 2 A or less 4 output points common terminal 8 A or less As for the number of outputs per common terminal refer to Chapter 5 interpretation of partition and the following manual Refer to FX3S Series User s Manual Hardware Edition 3 UL and cUL standards approved at 120 and 240 V AC 4 5 2 Life of relay output contact As for the details of life of relay output contact refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 4 5 3 Example of relay output wiring COMO Main unit 4 5 4 Cautions in external wiring As for the details of cautions in external wiring refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 4 6 Transistor output specifications and example of external wiring For details refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 4 6 1 Transistor output specifications Item Specification Number of output points 14 points Output connecting type Fixed terminal block M3 screw Output FX3S 30MT ES 2AD Transistor Sink Jeti FX3S 30MT ESS 2AD Transistor Source External power supply 5 to 30 V DC Resistance load 0 5 A point Max load Inductive load 12 W 24 V DC Open circuit leakage current 0 1 mA or less 30 V DC ON voltage 1 5 V or less 5 us or less 10 mA o
23. tric for information on UL cUL standard practices and the corresponding types of equipment Compliance with EC directive CE Marking This document does not guarantee that a mechanical system including this product will comply with the following standards Compliance to EMC directive and LVD directive of the entire mechanical system should be checked by the user manufacturer For more details please contact the local Mitsubishi Electric sales site Requirement for Compliance with EMC directive The following products have shown compliance through direct testing of the identified standards below and design analysis through the creation of a technical construction file to the European Directive for Electromagnetic Compatibility 2004 108 EC when used as directed by the appropriate documentation Attention e This product is designed for use in industrial applications Note e Authorized Representative in the European Community Mitsubishi Electric Europe B V Gothaer Str 8 40880 Ratingen Germany Type Programmable Controller Open Type Equipment Models MELSEC FX3S series FX3G series FX3U series manufactured from June 1st 2005 FX3U 232ADP FX3U 485ADP FX3U 4AD ADP FX3U 4DA ADP FX3U 4AD PT ADP FX3U 4AD TC ADP FX3U 232ADP MB FX3U 485ADP MB FX3U 4AD PTW ADP FX3U 4AD PNK ADP from April 1st 2007 from December 1st 2007 from November 1st 2008 FX3G 232 BD FX3G 422 BD FX3G 485 BD FX3G EEPROM 32L FX3G 2AD BD FX3G 1DA BD
24. use fire equipment failures or malfunctions Make sure to properly wire to the main unit in accordance with the following precautions Failure to do so may cause electric shock equipment failures a short circuit wire breakage malfunctions or damage to the product Make sure to properly wire to the main unit in accordance with the rated voltage current and frequency of each terminal The disposal size of the cable end should follow the dimensions described in the manual Tightening torque should follow the specifications in the manual Tighten the screws using a Phillips head screwdriver No 2 shaft diameter 6mm 0 24 or less Make sure that the screwdriver does not touch the partition part of the terminal block e Input output wiring 50 to 100 m 164 1 to 3281 long will cause almost no problems of noise but generally the wiring length should be less than 20 m 65 7 to ensure the safety 4 1 Wiring 4 1 1 Cable end treatment and tightening torque For the terminals of FX3S series PLC M3 screws are used The electric wire ends should be treated as shown below Tighten the screws to a torque of 0 5 to 0 8 Nem Do not tighten terminal screws with a torque outside the above mentioned range Failure to do so may cause equipment failures or malfunctions e When one wire is connected to one terminal 3 2 0 13 Terminal Solderless 6 2 mm 0 24 screw terminal or less 4 3 2 0 13 6 2 mm 0 24 Te Terminal
25. ush out all DIN rail mounting hooks below fig A A Th 2 Fit the upper edge of the DIN rail mounting groove right fig B onto the DIN rail 3 Lock the DIN rail mounting hooks below fig C while pressing the PLC against the DIN rail 5 3 4 Procedures for installing directly with M4 screws The product can be installed directly on the panel with screws This section explains the installation of the main units For the special adapters refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 3 4 1 Mounting hole pitches Refer to the External Dimensions section 2 2 for the product s mounting hole pitch information 3 4 2 Installation 1 Make mounting holes in the mounting surface referring to the external dimensions diagram 2 Fit the main unit A in the right figure based on the holes and secure it with M4 screws B in the right figure 4 Power supply input output specifications and examples of external wiring For the details refer to the following manual Refer to FX3S Series User s Manual Hardware Edition DESIGN PRECAUTIONS N WARNING e Make sure to have the following safety circuits outside of the PLC to ensure safe system operation even during external power supply problems or PLC failure Otherwise malfunctions may cause serious accidents 1 Most importantly have the following an e
26. ween terminal of special adapter and ground terminal For dielectric with stand voltage test and insulation resistance test of each product refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 3 For common grounding refer to section 4 3 4 The PLC cannot be used at a pressure higher than the atmospheric pressure to avoid damage 3 2 Installation location Install the PLC in an environment conforming to the generic specifications section 3 1 installation precautions and notes Installation location in enclosure Space in enclosure Special adapter can be connected on the left sides of the main unit If you intend to add special adapter in the future keep necessary spaces on the left sides FX3s Series main unit FX3S CNV ADP gt 50 mm 1 97 3 2 1 Affixing the dust proof sheet The dust proof sheet should be affixed to the ventilation port before beginning the installation and wiring work Be sure to remove the dust proof sheet when the installation and wiring work is completed For the affixing procedure refer to the instructions on the dust proof sheet 3 3 Procedures for installing to DIN rail The products can be installed on a DIN46277 rail 35 mm 1 38 wide This section explains the installations of the main units For the special adapters refer to the following manual Refer to FX3S Series User s Manual Hardware Edition 3 3 1 Installation 1 P
27. y cassette DISPOSAL PRECAUTIONS CAUTION e Please contact a certified electronic waste disposal company for the environmentally safe recycling and disposal of your device TRANSPORTATION AND STORAGE PRECAUTIONS Z CAUTION e The PLC is a precision instrument During transportation avoid impacts larger than those specified in section 3 1 by using dedicated packaging boxes and shock absorbing palettes Failure to do so may cause failures in the PLC After transportation verify operation of the PLC and check for damage of the mounting part etc Associated manuals How to obtain manuals For the necessary product manuals or documents consult with your local Mitsubishi Electric representative Associated manuals FX3S 30ML EL 2AD comes with this document hardware manual For a detailed explanation of the FX3S Series hardware and information on instructions for PLC programming refer to the relevant documents Specifications not described in this manual are same as FX3S PLC For details refer to the following manual Refer to FX3S Series User s Manual Hardware Edition Manual name Description Explains FX3S Series PLC FX3S Series User s Manual Sere een _ specification details for I O Hardware Edition MODE cone wiring installation and 09R535 ue maintenance FX3S FX3G FX3GC FX3U JY997D16601 Describes PLC programming FX3UC Series Programming _ for basic applied instructions p MODEL CODE