pm105 pressure meter user`s manual
Contents
1. the larger this effect will be Likewise when a system is put under pressure the tubes cavity etc will expand somewhat over time and hence the volume will increase and the pressure will drop as a function of the increased volume When pressure is introduced into the PM105 system by the pump a large amount of energy is stored in the unit When doing so the temperature of the oil will increase slightly as part of the introduced energy For this reason and the reasons listed above the indicated pressure will drop slightly over time as the system stabilises its increased temperature and the expansion of the tubes etc Depending on the applied this will normally take a few minutes If a pressure is generated e g 200 Bar and then dropped quickly down to e g 100 Bar the reverse function a slight increase in the pressure will occur for the same reasons If the ambient temperature changes over time and the unit is set to a fixed pressure the reading will change as a function of the change in temperature The above is a normal physical behaviour and should be taken into account in the operational procedures PM105 is temperature compensated over the entire temperature range and as such can be used with the listed accuracy In order to obtain full accuracy it is important to let the PM105 obtain the ambient temperature in the actual measuring environment This process may take approximently 3 hours Particular attention should
2. PM105 PRESSURE METER USER S MANUAL Manual revision 15 March 2001 SCSMANPOI15 Copyrighted 2001 PM105 user s manual Thank you for purchasing a Tek Know pressure meter The Tek Know products are manufactured by Scan Sense AS in ac cordance with our high quality standards in design choice of compo nents and workmanship in order to achieve maximum customer satis faction and to fulfil our vision to be our customers First Choice The PM105 is designed and manufactured by Scan Sense AS Tel 47 33 36 30 00 Bekkeveien 163 Fax 47 33 363001 N 3173 Vear www scansense no NORWAY post scansense no PM105 user s manual Contents SALE LV Se ks Bal PE 4 Certification if ie heh We eles ni niass 4 Warranty nn E 4 The mantah Re Rss Rene ttes 5 Introduction seen etat haleine TE 5 Unpacking ele areata 5 Operational Rint ss ss sens ie dent 6 Basic fUNCTIONS rss titi ot nt rente ter Cid ten 7 Operating s pphes ast sati 8 Trouble shooting fes rise heen An da in 8 Service and recalibration sus 9 Definition of terminology 9 NOTICE EE san trente LRU edt uct et dist na sente een ste 10 SD CITICATIONS asninn rai Ge ites 11 PM105 user s manual Safety Severe damage m
3. ay result if the PM105 is installed on a Dead End hydraulic system with a shut off valve in close line proximity Certain valves on operation may cause small Dead End volumetric changes which combined with the low compliance PM105 sensor can generate high pressure overload Make sure that the system is not under pressure when the connection is made up Certification ce Scan Sense certifies that this product meets its published specifications at the time of shipment from the factory Scan Sense further certifies that its calibration measurements are traceable to accredited international standards PM105 is tested and approved according to the following standards Imunity EN 50082 2 Emission EN 5008 1 1 EEx IS certification EEx ia 5 Warranty These Tek Know products are warranted against defects in material and workman ship for a period of one year from date of shipment During the warranty period Scan Sense will repair products that prove to be defective The product must be returned to a service facility designated by Scan Sense for warranty service or repair The foregoing warranty will not apply to defects resulting from improper or inadequate maintenance by buyer buyer supplied software or interfacing unauthorised modification or misuse operation outside of the environmental specifications for the product or improper site preparation or maintenance No other warranty is expressed or implied Scan Sense s
4. be made to the pressure gaskets fitted between the PM105 and the measurement pressure source Ensure that the correct size gasket is fitted for the selected pressure inlet adaptor and that the pressure gasket faces are undamaged and free from contamination e g sand grit etc PM105 user s manual Basic functions The various functions are selected from the key panel ON OFF ZERO TEST PEAK ON HOLD OFF TEKK KNOVYVY Switches the unit on or off When switched on the PM105 is initialised and starts to measure in the unit as default Sets the displayed pressure value to zero 0 000 within the limit of 0 to 125 of full scale If the pressure exceeds this limit the display will show HI HI The pressure must then be relieved to prevent damage Simulates applied pressure The value on the display should be in accordance with the value indicated on rear panel as test value The unit must not be pressurised during this test PEAK HOLD Toggles the device between normal operation and BAR PSI peak hold Peak hold is capturing transient pressure peak changes with a duration of at least 50 msec The display will show PH when Peak Hold is engaged Toggles between measuring units Bar or PSP The display indicates the unit selected with an pointing arrow PM105 user s manual Operating supplies The PM105 is a complete self contained instrument and does not require ad
5. ditional supplies i e replaceable battery hydraulic oil etc for normal operation Trouble shooting Pressure applied to the inlet The display does not read port exceeds zero offset 0000 when the ZERO range Reduce the pressure button is pressed at the inlet and repeat the zeroing operation The displayed value is not Perform zero adjustment in accordance with the f TEST prior to pressing the test stated test value when the baton test button is pressed Transients may be less than 50msec in duration and No transient pressure HOLD therefore not stored or Confirm if the peak hold function is toggled on BAR Displayed value does not Make sure that the correct PSI seem to be in accordance measuring unit is selected with the applied pressure with the bar PSI buttons If these remedy s don t solve the problem the PM105 probably needs to be serviced Please send it to your supplier Please include an accurate description of the problem PM105 user s manual Service and recalibration Any instrument requires periodical recalibration to comply with the stated accuracy Please refer to the enclosed test report for recalibration date Please return your instrument to your supplier on the given recalibration date for recalibration if you need to maintain a valid calibration of the PM105 This instrument is fully digital without any trimmers The unit must be servic
6. ed and recalibrated by authorised distributors with calibration equipment and software Definition of terminology Calibration Curve Creep Characteristic Yop eet Te iets Uor Full range pressure i AUp UFR applied to to 10 0 Applied pressure 100 FR Time Residial output P 0 U oz Creep ToD ing Test Temperature Ambient T1 10 min UFR Uog N Lipst 08 _ 0 ZFRO UFR Hysteresis Voa 6100 FRO UFR Due to various standards and to variations in the understanding of those the above list is a definition of terms used for the calibration and certification of our products PM105 user s manual 10 Notice Systems with digital display i e PC400 PC700 PM105 If the system is specified as 0 05 FS BSL accuracy this means that the maximum deviation on a 400 Bar unit can be 0 05 FS 1 resolution unit 0 2 0 1 0 3 Bar above 100 Bar and 0 2 0 05 0 25 Bar below 100 bar FS always means the full range of the unit independent of any auto range on the instrument since this is related to the transducer and should be used in the calculations PM105 user s manual Specifications Display 12 5mm LCD 4 digit Physical dimensions 92x98x33 mm WxHxD x 0 001 0 001 20 0 001 Pressure ranges 50 x 0 01 Bar G 100 x 0 01 200 x 0 1 450 x 0 1 700 x 0 1 Better tha
7. hall not be liable for any direct indirect special incidental or consequential damages whether based on contract tort or any other legal theory The warranty does not cover the internal rechargeable battery PM105 user s manual The manual This Manual is for reference only Specifications may change at any time Introduction The PM105 is a series of digital portable pressure meters for commissioning service calibration and maintenance applications The unit is light weight and ergonomically designed for on site applications PM105 gauge is completely self contained with integral pressure sensor precision thin film strain gauge CPU based signal conditioning surface mount electronics 4 digit LCD display and internal battery power supply An internal temperature sensor compensates for thermal zero and sensitivity errors which combined with an optimised autorange facility ensures excellent accuracy over a wide pressure range Unpacking On receipt please check all received parts A standard PM105 system includes the following Pressure meter Battery charger Calibration report User s manual Optional EEx certificate PM105 is equiped with a 7 2V NiCad rechargeable battery PM105 user s manual Operational hints When a closed volumetric system is subjected to a change in temperature the pressure in the system will change as a function of the expansion of the liquid media The smaller the volume in the system
8. n 0 1 or 0 05 combined error Accuracy FS Includes non linearity repeatability zero and sensitivity temperature effects Pressure element Wetted parts 15 5 stainless steel construction Extruded aluminium Anodised Bar or PSI selectable Pressure inlet 1 4 BSP Femak Process temperature 10 C to 60 C Operating temp environmental 10 C to 50 C Dr aan All liquids or gases compatible with 15 5 PH stainless steel 11 PM105 user s manual Internal 7 2V rechargeable NiCad battery Approximently 20 hours operation between each recharging Cher 10mA constant current e 12 14 hours charging time Traceable to international standards Calibration Refer to the enclosed calibrationcetificate for the specific unit EEX IS certification EEx ia T5 12