1. a 5 44 AM 5 29 14 Page 5 8 drive web automation savvyPanel touch Operations Guide e Operator station configurations are stored in the drive web devices and are available in savvyPanel touch when the network discovery filters and passwords cohere savvyPanel Display Overview IP65 Bezel 325 0 9 50 Kitto 9 50 savvyPanel Tile array Status Bar with drive web button page name Alarm indicator and button and Home and or Systems button savvyPanel Pages Systems Page is available when multiple savvyPanel systems are discovered Each savvyPanel system may contain tiles from many drive web devices Each drive web device may contribute to only one savvyPanel system Right click on device icon in Savvy for the contextual menu gt Set savvyPanel System e Touch the systems button fa in the status bar to access the systems page from home page Lock this button with home password Click savvyPanel touch icon in Savvy to set the home password Choose User Manual under the Help menu and refer to Appendix B savvyPanel touch User Guide for more details Home Page is the first operator page in a savvyPanel System Access home page from any operator page with the home button E Lock with the home password Operator Pages show graphic page link and parameter tiles Pages can be renamed The name appears in the status bar Alarms Page operator page number 255 can be accessed from I
2. any operator page via the alarm indicator and button which appears in the status bar next to the home button e Alarm indicator and button is only present when a drive web device in the currently viewed savvyPanel system has a savvyPanel Alarm Annunciator function block with an active input savvyPanel touch HG503545Iss1 wwuw driveweb com Page 6 8 drive web automation savvyPanel Tiles Parameter Tiles Touch a settable parameter to see its savvyPanel Setter Select between 5 two setter styles with the e button Return to previous setting ic Return to default m Hold down the increment or decrement buttons for faster changes e A parameter is settable if it is not read only and has no incoming drive web connection Meter Digital panel meter dial or bar meter Unipolar bipolar full scale and percent choices Indicator Variety of colors Shows on off true false boolean state All non zero values are true Pushbutton Momentary actuators in a variety of colors also lighted Start Stop Multi position Switch For enumerated parameters Operator s note If communication with a drive web device is interrupted affected tiles show a yellow bar at top with exclamation warning The displayed value is not updated 100 00 Graphic Tiles Create diagrams with various process elements Page Link Tiles A graphic tile that is also a page link Touch to change the view to that page drive web button is l
3. Typically savvyPanel touch must be on the same subnetwork as the drive web devices that it interfaces with Contact us page 8 or your company s IT department for assistance with more complex network routing requirements Ethernet Network Requirements e A standard Category 5e cable with 8P8C RJ 45 connectors on both ends for each driv e web device and the host computer e An Ethernet switch with ports for all drive web devices and your computer New to drive web e We strongly recommend attending our free on line training seminars Io register and get your invitation call or e mail training driveweb com e Before proceeding with your systems designs it is very important to familiarize yourself with Savvy the configuration software e We strongly recommend you read the User Manual and Getting Started Guides under the Help menu e Use Create Phantom in the Directory menu to practice explore all driv web products and options and design and configure off line Design systems in Phantom devices and Export Data under the Directory menu for later use in live devices Import Data into phantoms to work off line Set up savvyPanel touch with free savvy software e To download the latest version of Savvy go to wuww driveweb com and click on get savvy e Java Runtime Environment must be installed to run savvy There is a link on the get savvy page to download Java for free e If you do not have internet access
4. install savvy and Java from the Bardac Infodisk Browse to the Savvy link off line installation Contact us for the files or Infodisk savvyPanel touch HG503545Iss1 wwuw driveweb com Page 4 8 drive web automation Set up savvyPanel touch with free savvy software continued Choose Open Device Directory from the File menu See discovery settings under the Directory menu savvyPanel touch can be discovered when it has a valid IP address in the same subnetwork as the computer gt dw230 It is essential to refer to the savvyPanel touch User Guide in the savvy User Manual e Choose User Manual under the Help menu and refer to Appendix B savvyPanel touch User Guide e savvyPanel touch User Guide is also available on line at driveweb com su ort manuals driveweb en_dw230 html e Set IP addresses passwords discovery filters logos etc using the Savvy software Design savvyPanel Pages for dw230 Note savvy SFD upgrade is required to make design changes ina SsavvyPanel system Optimal tile layouts to fill the screen are rows x columns 50 00 STO inhibit DINI T2 Orive Fault esb OM 9 50 I ee o Motor Speed Drive Run Running OK to Run High Healthy Operator ft r Operator 60 0 iy 0 0 E JJEBEB n Line Corarot ons BNM savvyPanel touch HG503545Iss1 www driveweb com Stopped 0 00 Direction Motor Current Forward 00A at 5 0 0 0 L EEN a EEDI
5. smarty DIN rail driv e web controller e Sixteen flexible bipolar analog digital I O e Hardware options dual serial ports add six digital inputs frequency I O relay rack dual stepper control e External options remote dual encoder module with re transmit high Voltage I O e Encoder control cyclic and linear positioning electronic line shaft registration event counts speedy ultra miniature drive web controller e Standard models with permanent bond mounting e Drive dedicated models with 7 lead and specified connector fitted e Generic ModbusRTU with 15 solid wire leader e PLIX digital DC drive versions install in expansion slot e DIN rail mount option specify dwOption 50 savvy SFD Signal Flow Diagram upgrade Required for building or editing savvyPanel tile layouts savvyPanel operator touch station app for for 10S Apple mobile operating systems drive web products are designed amp assembled in the U S A Get drive web help Call or Email techsupport driveweb com drive web training courses Free online interactive training seminars take about one hour Specialized online and factory training sessions are also available To register email training driveweb com or call
6. art or operate in an unexpected dangerous or lethal way It is essential that you are completely familiar with all of the equipment and the system design before attempting to program or edit a program or connect to any live device It is also essential that a risk assessment 1s conducted to identify hazards Risks must be reduced to tolerable levels product By configuring or using these products you agree to indemnify and hold harmless Bardac Corporation its employees directors officers distributors and resellers against the consequences of your configuration or use of the products Warning Information in this manual is subject to change without notice You are responsible for verifying the proper operation of your savvyPanel touch panel Special care must be taken after loading new firmware A Warning You are entirely responsible for the configuration or use of any drive web Warning Avoid permanent damage to your savvyPanel touch never exceed any min or max values Do not connect any savvyPanel touch terminal to mains circuits savvyPanel Bardac and drive web are trade marks of Bardac Corporation registered in the U S and other countries savvyPanel touch HG503545Iss1 www driveweb com Page 1 8 drive web automation Product identity savvyPanel touch model dw230 dwi230 is a 7 high resolution touch panel operator interface for industrial process automation using drive web distributed control over Ethernet To config
7. drive web lg Sa vvyPanel S oe TELLE touch automation model dw230 7 Operator Touch Interface Installation amp Operation Manual Contents az age CE Approvals Warnings savvyPanel dw230 Identification Standard Features dw230 Installation and Panel Mounting Information drive web Ethernet and Introduction Set Up savvyPanel touch with Free savvy Software Design savvyPanel Layouts for dw230 v J savvyPanel Operations Guide drive web Product Line Highlights 0O o 0D U yA Ae O Nme Qi Free drive web Online Training Seminars C Conformity Statements EMC Standard EN 55022 2010 EN 55024 2010 LVD Standards EN 60950 1 2006 A11 2009 A1 2010 A12 2011 savvyPanel touch is an industrial controller designed for permanent installation by qualified professionals If it is used in a manner not specified herein the protection provided may be impaired savvyPanel touch and its packaging contain recyclable materials Warning It is essential that you read and understand this entire manual and the entire contents of the savvy software Help menu before proceeding with your installation and configuration See page 4 for savvy installation instructions For more information and to download manuals and software go to www driveweb com or contact us See page 8 Warning Your use of savvyPanel savvyPanel touch savvy software and drive web devices may cause motors and machinery to power up with high Voltages or st
8. ing Temperature Operating 0 C to 50 C Storage 20 C to 60 C Altitude 3000m max Ethernet MDI 8P8C RJ45 jack 100baseTX 10BaseT Full Duplex Auto Negotiation Auto MDIX IEEE 802 3ab LEDs 100 Green LED indicates 100Base TX Ethernet connection Link Activity Yellow LED On for Link flash for activity USB Type A jack for USB pointer device e g industrial mouse Plug device in prior to power up dw230 Panel Mounting Provide a cutout in a metal industrial panel 6mm 1 thick max Ensure that the finished opening and surrounding area are flat Imm 0 04 maximum deviation Install four panel mounting clips and tighten screws 0 25 Nm 2 2 inlbs Do not over tighten the clip screws The screen may be 42mm 0 5 permanently damaged i A Panel Drawing Note Cutout Dimensions Front view grey bezel 118mm 4 65 area must be flat See above 9mm 0 35 t 6mm 0 25 e 4 5mm 0 2 drive web automation drive web Ethernet networking amp programming Before proceeding it 1s important to have a basic A understanding of Ethernet TCP IP networks Creating an invalid or duplicate IP address will cause serious network malfunctions e Find useful networking information Under the Help menu click on Getting Started with savvy e savvyPanel touch ships with the IP address 10 189 189 190 Consult your company s IT department for an appropriate unique IP address e
9. ocated at bottom left drive ai Touch the drive web button web to view description model number firmware version contact information Touch the target button P to adjust the touch calibration Proceed with caution If the touch calibration is badly adjusted it may be necessary to plug in a USB pointing device Please see the installation manual for details Carefully touch the crosshair cursor that appears Hold the position for approximately one second The best calibration may be achieved with an appropriate stylus Another cursor will appear until this is repeated in four locations savvyPanel touch HG503545Iss1 www driveweb com 85 00 0 00 X 109 09 X 7 8 9 4 5 6 WAAC v SHAE S i gt wi O 0 x Speed Setpoint 85 00 Health oK Water Cycle Start at Next Process Type Full Speed S Winder Setup D Ki drive web savvyPanel dw230 x1000 bitp wew driveweb com imoadriveweb com 1 410 604 3400 x Page 7 8 drive web Product Line Highlights Drive dedicated smarty and speedy models Supported Drive smarty Model speedy Model Generic dwg 10 dwi220 PL X Digital DC Drive dwe 11 dw22 1 Optidrive P2 dwe 14 dw2e4 Optidrive Plus dwe 13 dw2e3 Optidrive HVAC dw2i6 dw2e26 Optidrive E2 dw2ei2 dw222 Optidrive E2 Single Phase Motor dwe 12 dw2ee YaskawaF7 dwg 15 dw2e25
10. ure a savvyPanel touch you must get the savvy software tools from wwus driveweb com Please see page 4 To find the savvyPanel touch firmware version launch savvy and choose Get Detailed Info from savvyPanel touch contextual menu savvyPanel touch Specification edrive web distributed process control and savvyPanel display technology e 10 100Base T X Ethernet page 3 e Update firmware with savvy software Resolution 1024 x 600 pixels e Brightness 250nit e Ingress protection IP65 in front of panel seal IP20 behind Details on next page Configure basic security passwords panel specific home password IP addresses discovery filters and more using free drive web savvy software savvyPanel Technology Overview e savvyPanel touch displays systems and pages that are configured in drive web smarty and speedy controllers Please see the product manual for that device for details Product manuals may be found on the web at http driveweb com tech update php drive web devices must have dWOPTION 26 installed to display the complete suite of tiles A limited set of tiles 1s available without this software option Software options may be added at any time Please see the product manual for details Discovery of drive web devices is controlled by the network configuration savvyPanel touch setup and passwords Control savvyPanel touch network setup discovery and launch options and passwords with savvy soft
11. ware See the savvyPanel touch User Guide that is available in Appendix B of the savvy User Manual Open the savvy User Manual from the Help menu or on the web at http driveweb com support manuals driveweb en html e savvyPanel systems and pages are consistent in all savvyPanel devices including savvyPanel for i1OS Apple mobile operating systems and savvyPanel running on an industrial computer smarty and speedy are trademarks of Bardac Corporation registered in the U S and other countries Apple and iOS are trademarks of Apple Inc registered in the U S and other countries savvyPanel touch HG503545Iss1 wwuw driveweb com Page 2 8 drive web automation dw230O Installation Rear View Typical panel mounting clip drive web savvyPanel mn ESO un savvyPanel ana touch serial number label USB jack Ethernet jack Power Regulated 22VDC min 32VDC max 6W Do not connect to a distributed DC power network External 1A fast acting fuse or 1A current limiting is required Connect to and on terminal block P2 G may be used for earth or chassis ground connection Terminal wiring Strip 5mm 0 20 or use ferrules 0 2mm AWG24 min 1 5mm AWG 14 bare wire max Terminal tightening torque 0 25 Nm 2 2 in lbs max Environment P65 up front with included bezel gasket part number HJ503515 correctly installed IP20 inside panel environment UL IEC Pollution Degree 2 Humidity 95 max non condens
Download Pdf Manuals
Related Search
Related Contents
JVC BD-X201M DVD Recorder User Manual 240KB コムシスホールディングス(1721) vtss100 – stazione per riparazioni smd Digitus DA-70202 signal cable Windmere CO-9510D Use & Care Manual PCG-F104K - Sony Europe Jocel JF-260L refrigerator LFA7_Motionnet Dell Lifecycle Controller Integration Pack para Microsoft System Copyright © All rights reserved.