Home

LPC2 A01 User Manual

image

Contents

1. Zo 8 m p3 60 e Dimensions in millimeters All connections module attachments and assembling must be done while module is not connected to the main power supply Mounting instructions 1 Switch OFF main power supply 2 Mount LPC 2 A01 module to the provided place inside an electrical panel DIN EN50022 35 rail mounting 3 Mount other LPC 2 modules if required Mount each module to the DIN rail first then attach modules together through K1 and K2 connectors 4 Connect devices and sensor wires according to the connection scheme in Figure 2 5 Switch ON main power supply 6 Green LED should switch on according to the Table 6 Dismount in reverse order For mounting dismounting modules to from DIN rail a free space of at _ Longo programmable controller LPC 2 A01 module SMARTEH LIVING SYSTEMS least one module must be left on the DIN rail NOTE LPC 2 MC3 main control module should be powered separately from other electrical appliance connected to LPC 2 system Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard Longo programmable controller LPC 2 A01 module SMARTITEH LIVING SYSTEMS 3 3 Module labeling Figure 4 Labels on housing Label 1 MC3 sample Label 2 MC3 sample LPC 2 MC3 P N 225MC304001001 S N MC3 S9 05000001 90 Dic 16 05 C Label 1 description
2. SMARTEH LIVING SYSTEMS USER MANUAL Longo programmable controller LPC 2 A01 module Version 5 SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail info smarteh si www smarteh si ongo programmable controller LPC 2 A01 module SMARTER LIVING SYSTEMS Written by SMARTEH d o o Copyright 2012 SMARTEH d o o User manual Document Version 005 July 1 2012 Longo programmable controller LPC 2 A01 module SMARTER LIVING SYSTEMS STANDARDS AND PROVISIONS Standards recommendations regulations and provisions of the country in which the devices will operate must be considered while planning and setting up electrical devices Work on 230 VAC network is allowed for authorized personnel only DANGER WARNINGS Devices or modules must be protected from moisture dirt and damage during transport storing and operation WARRANTY CONDITIONS For all modules LONGO LPC 2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power we offer warranty for 24 months from date of sale to end buyer In case of claims within warranty time which are based on material malfunctions the producer offers free replacement The method of return of malfunctioned module together with description can be arranged with our authorized representative Warranty does not include d
3. 1 LPC 2 MC3 is the full product name 2 P N 225MC3040001001 is the part number 225 general code for product family MC3 short product name 04001 sequence code 04 year of code opening 001 derivation code 001 version code reserved for future HW and or SW firmware upgrades 3 D C 16 05 is the date code 16 week and 05 year of production Label 2 description 1 S N MC3 S9 0500000190 is the serial number MC3 short product name S9 user code test procedure e g Smarteh person xxx 0500000190 year and current stack code 05 year last two cyphers 00000190 current stack number previous module would have the stack number 00000189 and the next one 00000191 m Longo programmable controller LPC 2 A01 module TA iy 4 TECHNICAL SPECIFICATIONS Table 5 Technical specifications SMARTTEH LIVING SYSTEMS Power supply from internal BUS Number of analog inputs 6 Number of analog outputs 2 Connection type screw type connector for stranded wire 0 75 to 2 5 mm Max power consumption 5 W analog input output type voltage current Max current consumption 1 mA per input 20 mA per input Max current consumption 20 mA per output 20 mA per output Analog input measuring error of the full scale value DE LE Analog output accuracy of the full 1 13 scale value Load resistance for analog out
4. 0 20 mA Rin 10 7 KO R 182 Q 3 16 VDC IN3 6 U1 GND 10 VDC 10 IN4 7 1 analog input 0 10 V analog input 0 20 mA Rin 10 7 KO Rin 182 Q r 16 VDC IN4 8 U1 GND 10 VDC 10 IN5 9 1 analog input 0 10 V analog input 0 20 mA Rin 10 7 KO R 182 Q 3 16 VDC IN5 10 U2 GND 10 VDC 10 IN6 11 1 analog input 0 10 V analog input 0 20 mA Rin 10 7 KO Rin 182 O i 16 VDC IN6 12 U2 GND 10 VDC 10 Table 3 Outputs set as voltage set as current OUT1 13 Q analog out 0 10 VDC analog out 0 20 mA OUT1 14 GND OUT2 15 Q analog out 0 10 VDC analog out 0 20 mA OUT2 16 GND Table 4 K1 Internal BUS Data amp DC power supply Connection to I O module Table 5 K2 Internal BUS Data amp DC power supply Connection to I O module 1 Wires connected to the module must have cross sectional area at least 0 75 mm Minimum temperature rating of wire insulation must be 85 C 2 Pins IN1 2 IN2 4 IN3 6 and IN4 8 are always on the same potencial selected through correspondent jumper 3 Pins IN5 10 and IN6 12 are always on the same potencial selected through correspondent jumper Longo programmable controller LPC 2 A01 module SMARTER LIVING SYSTEMS Table 6 LED1 On OK Blink A01 in fault state Status Green LED indicates A01 state 3 2 Mounting instructions Figure 3 Housing dimensions
5. C Composer software help menu a Longo programmable controller LPC 2 A01 module SMARTER LIVING SYSTEMS 2 FEATURES Figure 1 LPC 2 A01 analog module Table 1 Technical data 2 analog outputs 6 analog inputs Voltage or current input output set with jumper Voltage current input range 0 10 V 0 20 mA lt 0 5 lt 1 meas error of full scale Voltage current output range 0 10 V 0 20 mA 1 3 accuracy of full scale value On input connector ground reference GND 24 VDC 16 VDC 10 or 10 VDC internal supply is provided jumper configurable Each input and output can be set as current or voltage type jumper configurable Standard DIN EN50022 35 rail mounting Longo programmable controller LPC 2 A01 module SMARTITEH LIVING SYSTEMS 3 INSTALLATION 3 1 Connection scheme example Figure 2 Connection scheme example e LPC 2 A01 a Longo programmable controller LPC 2 A01 module SMARTER LIVING SYSTEMS Table 2 Inputs GND es ov 2av set as voltage set as current IN1 1 1 analog input 0 10 V analog input 0 20 mA Rin 10 7 KO Rin 182 Q 16 VDC IN1 2 U1 GND 10 VDC 10 IN2 3 1 analog input 0 10 V analog input 0 20 mA Rin 10 7 KO Rin 182 O r 16 VDC IN2 4 U1 GND 10 VDC 10 IN3 5 1 analog input 0 10 V analog input
6. amage due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVICE THIS PRODUCT YOURSELF This device must not be installed in the systems critical for life e g medical devices aircrafts etc If the device is used in a manner not specified by the manufacturer the degree of protection provided by the equipment may be impaired ST Waste electrical and electronic equipment WEEE must be collected separately LONGO LPC 2 complies to the following standards e EMC EN 61000 6 2 EN 50082 EN 61000 6 4 EN 50081 e LVD IEC 61131 2 e Vibrations and climatic mechanical EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 Smarteh d o o operates a policy of continuous development Therefore we reserve the right to make changes and improvements to any of the products described in this manual without any prior notice MANUFACTURER SMARTEH d o o Trg tigrovcev 1 5220 Tolmin Slovenia _ Longo programmable controller LPC 2 A01 module SMARTEH LIVING SYSTEMS Index Longo programmable controller LPC 2 A01 module T DESCRIPTION esse eenn ennn dekte S E en eenen 1 L FEATURE a ne 2 SINS PURE T
7. e sossen oneens nae eeneasseteeas aceamenees cteaveawenamesacawanser vere 3 3 1 Connection scheme example ss eneen eenen 3 3 2 Mounting INSUIUCTIONS cccscceinscncsececevecesescdesdeceesscedscncesedeessasenseeaescs 5 D MOGUNGNADCUING senen derven enen E tie set ene 7 4 TECHNICAL SPECIFICATIONS aa eneen ee 8 CHANGES RER E ETE E EE ENR 9 NOTES te 10 5 jii Longo programmable controller LPC 2 A01 module SMARTER LIVING SYSTEMS 1 DESCRIPTION LPC 2 A01 module has a lot of settings to customize the application It s general purpose is to measure analog values and generate output analog signals Module is powered from internal BUS Each input or output can be configured as voltage or current type through correspondent jumper Inputs have an additional setting for its second terminal voltage If signal is sourced from outside active device then jumper is set to GND In this case input measures the analog value in reference to GND Otherwise if NTC or other passive sensor is connected to input jumper should be set to 10V If a two wire current device is connected jumper should be set to 24V 16V 10 There are two jumpers bottom one is common for first four inputs top one for last two inputs refer to Table 2 and Table 3 The lowest power consumption of LPC 2 A01 module is achieved with ground referenced inputs and voltage type outputs NOTE For proper system configuration and data allocation please refer to LP
8. puts R gt 500 Q R lt 500 0 Analog input range 0 10 V 0 20 mA Analog output range 0 10 V 0 20 mA Max transition time per channel 15 Max total source current from 10V 20 mA supply terminals Max total source current from 24V 120 mA supply terminals ADC resolution min 3900 levels DAC resolution min 450 levels Dimensions L x W x H 90 x 53 x 60 mm Weight 90 g Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Maximum altitude 2000 m Mounting position vertical Transport and storage temperature 20 to 60 C Pollution degree 2 Protection class IP 30 Longo programmable controller LPC 2 A01 module SMARTEH oy LIVING SYSTEMS CHANGES The following table describes all the changes to the document Date V Description 31 3 2006 003 The initial version issued as LPC 2 A01 module UserManual 4 5 2009 004 Update graphic 11 5 2010 005 Updated warranty permanence _ m Longo programmable controller LPC 2 A01 module SMARTER LIVING SYSTEMS NOTES