1. sss Single frequency or scanner on limited band Frequency range 200 Hz 6 MHz Measurement accuracy up to 2 MHz 1 dB between 0 60 dB up to 6 MHz 2 dB between 0 56 dB e Single End Insertion Loss with Advanced Software 1 Measuring Mode readout by FDR technology on High Band Spectral readout Operating Band l a direct 100 KHz 1500 kHz Graphic Extrapolation 20 kHz 2 2 and 30 MHz Operative Impedance 120 Q default balanced line Operative limits c minimum line length 100 meters maximum attenuation before extrapolation 56 dB Event Tests e Micro Interruptions 0 62 base band and wide band Threshold level 2006 3 20dB 2 kHz Test Tone default or on programmable input frequency up to 6 MHz Monitoring time 0 4 min 24 ours Events indicators 5 Counters 0 3ms gt 1min Event Time Secs with Events ReadOut ccceeeeeeeeeeeeeeeeees Tabular and Time Domain Histogram representation Measure facilities 0 2 kHz reference tone output from TX connector for loopback tests e Impulsive Noise O 71 base band and wide band with Advanced Software 2 Threshold level 0 60 dBm Base band BW filters 200 12 000 Hz Flat 600 3 000 Hz 300 500 Hz DSL bands PB filters 20 k
2. gt 200Hz fo lt 4 kHz 200 Hz fo gt 4 kHz selective for telegr chann 120 240 360 480 Hz e high band 20 kHz 6 or 30 MHz selective 25 100 200 400 Hz and 1 74 3 1 4 0 8 0 16 0 kHz Spectrum and Network Analyzer Frequency range e from 200 Hz to 6 MHz two band base version e up to 30 MHz by optional module EBM 30 Input impedances balanced e base band 150 200 600 and gt 10 KQ e middle band 100 110 120 135 150 Q and gt 10 KQ e high band 100 Q and gt 5 KQ Input impedances unbalanced 50 and 75 Q by Banana BNC optional adapter Base band measure method 200 25000 Hz by FFT analyzer Kaiser window SPAN rdn alee 6250 12500 and 25000 Hz Resolution horizz vertical 250 pixel 10 div 625 1 250 2 500 Hz div 192 pixel 8 div 1 2 3 20 dB div Resolution BW 50 100 200 Hz other resolutions are interpolated Middle band measure method 1 kHz to 6 30 MHz by Digital SSB quad conversion Span pegia gna e 30 ranges from 10 to 8000 kHz 10 per decade Resolution horizz vertical 250 pixel 10 div 1 2 4 8 16 800 kHz div 192 pixel 8 div 1 20 dB div Resolution BW 0 2 0 5 1 2 5 8 kHz other resolutions are Interpol High band measure method 10 kHz to 30 MHz double conversion receiver optional module Bands 0 12 0 18 0 30 MHz Level reading mode
3. 4 absolute dBm dBm Hz dBV and dBr relative Measurement mode normal peak max mean or min value 2 Wires for Return Loss measurement 2 Wires for Longitudinal Balancement measurement and 4 Wires Input range s es from noise floor 12 dBm 1000 Noise floor TX OFF 130 dBm Hz up to 30 MHz Resolution marker lev freq 0 1 dB as selected resolution BW Network Analyzer eee by tracking generator or single freq in 2 4 wires mode Mix measurements Generator Meter and Network Analyzer e Cross Talk si ies Test mode tetteseaees eee Near End Single End and Far End End to End single frequency or scanner on limited band Frequency range 0 200 Hz 6 MHz up to 30 MHz EBM 30 opt module Measurement accuracy up to 2 MHz 1 dB between 0 90 dB up to 6 MHz 2 dB between 0 86 dB up to 30 MHz 3 dB between 0 80 dB Intrinsic crosstalk 1 S 90 dB with precise resistive load e Return Loss 2 wires Test MOdG x ciae en single frequency or scanner on limited band Frequency range eeee 200 Hz 6 MHz up to 30 MHz EBM 30 opt module Measurement accuracy up to 2 MHz 1 dB between 0 50 dB up to 6 MHz 2 dB between 0 46 dB up to 30 MHz 3 dB between 0 40 dB e Longitudinal Balance Loss 2 Wires Gnd Test mode
4. Tests if coupled with another ACT6000 The wide kind of measurements of the ACT6000 allows the qualification and certification on various communication carriers and copper pairs used for digital streams with a frequency occupancy up to 6 MHz or 30 MHz optional moreover the instrument can automatically extrapolate the ADSL and VDSL maximum expected data rate of the copper line under test COPPER PAIRS DIAGNOSTIC amp FAULTS FINDING LOCATION ACT6000 can be configured for high troubleshooting mission by special functions and internal optional modules The complete adoption of these modules allows the simple and fast individualization of anomalies and or faults on the copper line and communication systems ACT6000 TECHNICAL CHARACTERISTICS General ee ee ABS shielded for EMI EMC compatibility Connections weiss ee RTX connectors IN OUT and TX OUT triple banana jack e polarized connector for external supply e RJ 45 4 connector for headset e USB amp RS232 port for PC connector e USB for Pen drive connector DIS AY e e LCD color 320 x 240 pixel 1 4 VGA back lighted Power supply internal e rechargeable battery pack green NiMh e external from 16 5 to 26 5 Vdc max 2 5 Ah Dimensions and Weight 150 x 210 x 50 mm 1 5 Kg batteries included Temperature range 000 operative 0 45 C stock 20 70 C Humidity range n 5 90 no condens
5. for Voice ISDN HDSL E1 T1 SDSL G SHDSL ADSL ADSL2 VDSL 1 2 and Base band M1040 M1020 G 712E2 EURO16k EURO32k MIL16k MIL32k 2 or 4 Wire mode Only _Transmissives Noise bilateral Return Loss bilateral Longitudinal Balance Loss bilateral LCTL Insertion Loss SNR bilateral ADSL ADSL2 and VDSL Bit Rate evaluation Up amp Down stream NEXT and FEXT Notes by Advanced Software 1 by Advanced Software 2 by adoption of EBM 30 optional module Accessories base kit ACT6000 Base instrument included Nylon Carrying Case with the pocket for accessories User Guide English or Italian language as requested AC Power Supply and Battery Charger Line Input 220 Vac Output 20 Vdc 1 4A Banana Banana Crocodiles shielded cable 2 30m total length Ground Cable unipolar Banana Crocodile cable USB Pen Drive Accessories and optional modules ASW1 Advanced Software 1 see the above description ASW2 Advanced Software 2 included PC utility programs Full Remote Control Soft Update Capture Screen Export amp Read Saved Tests ANSI or ETSI Masks Editor ACT 11 POTS Module Subscriber Simulator Module for POTS for signalling tests 1 ACT 12 DMM Module Digital Multimeter Module for metallic tests ACT 13 EBM30 Module Extension Band Module for 30 MHz operation ALT 05 Headset with 2m cable and RJ 45 4 connector ALT 09 Resistive Termination
6. Advanced Communication Tester SINE SIGNAL amp NOISE GENERATOR SELECTIVE LEVEL METER CROSS TALK METER SPECTRUM amp NETWORK ANALYZER LONGITUDINAL BALANCE amp RETURN LOSS METER MI CROI NTERRUPTION amp IMPULSIVE NOISE METER VOLTAGE RESISTANCE CAPACITANCE METER TDR amp RESISTANCE FAULT LOCATOR POTS DEVICE SIMULATOR ALL ON THE PALM OF YOUR HAND This new instrument combining various kinds of transmission metallic and special tests may be considered up to today the most advanced Test Set for qualifying and maintenance of advanced transmission systems and copper pairs used for various telecommunication services ePOTS elSDN eTl oe E1 eHDSL 1 2P eSHDSL eG SHDSL eADSL eVDSL ERGONOMIC CHARACTERISTICS One of ACT6000 most interesting EE crtsooo features is the colour LCD high er resolution graphic display a real window on the most advanced measurements world The alphanumeric keypad as well as the function keys grant to the instrument a high operating level Moreover don t miss to notice that due to its accurate and intuitive Human Machine and Graphics User Interface this instrument doesn t need the help of the user s manual if not to arrange and carry out unusual measurements and or settings DATA COMMUNICATION CHANNELS amp COPPER PAIRS QUALIFICATION CERTIFICATION One ACT6000 if suitably configured can perform easy and quick Single End Tests or very accurate End to End
7. Hz 6 MHz E F G and special filters Monitoring time 4 min 24 hours Events indicators 1 Event Counter Event Time Ratio Secs with Events Readout eerten eleri Tabular and Time Domain Histogram representation Special Measurements e Line Immunity by White Noise injection Output level range 70 144 dBm Hz Zref 1000 0 1 dB Resolution Output impedance 1350 Q balanced Ref impedances 100 120 135 150 Q Bandwidth a 1 kHz 6 MHz e TDR Fault locator Distance ranges 90 180 450 900 1800 3600 7200 m 0 600 PVF ZOOM sheen eni oi end e ned sancnetisss vertical 8 77 dB horizontal 1x 2x 4x Distance resolution by marker minimum range about 0 4 meters or 1 feet maximum range about 40 meters or 100 feet Operative mode 0605 single line 2 wires Crosstalk 4 Wire Differential by relative comparation with other line Monitoring to events localization by Peak mode Sample amp Hold Pulse output level 2 short and long 2 2 Vpp Boost 5 5 Vpp Pulse length automatic on range selection from 10 to 5000 ns IN OUT impedance 100 110 120 135 150 Q balanced TGC automatic gain control 0 6 dB km Propagation velocity PVF 0 300 to 0 999 o PV 90 to 300 m us e Digital Multim
8. Set 100 120 135 150 and 600 Q ALT 15 Probe to perform High Band PSD measurements on powered lines ALT 16 Banana to BNC Adapter Note options applicable only for the Advanced Software 2 ATEN S r l Via dei Lavoratori 180 04100 LATINA ITALY Tel 39 0773 240696 Fax 39 0773 240676 e mail sales aten it Web www aten it Aten S r l reserves the right to change this preliminary specifications without prior notice
9. eter DC AC by DMM optional module Measuring mode between a b a c Gnd b c Gnd and reverse DC Voltage Range Accuracy 0 140 Vdc lt 2 of reading 1 digit AC Voltage Range Accuracy 0 100 Vrms lt 2 of reading 1 digit up to 1kHz DC Resistance Insulation Test Voltage eee E 100 Vdc with current limitation 1mA max Range Accuracy 2 500 MQ 50 200 MQ lt 2 of reading digit LINE LENGTH BY LOOP RESISTANCE Line length evaluation as function of measured resistance Line Resistance eee 10 to 999 Q m or 3 to 304 Q ft Range Resolution 0 0 to 99 999 kUnits meters or feet 1 units CCUFACY adc cen 20 Tale nat teeta ten oeees as derived from measured resistance DC CAPACITANCE time of DC discharge method Test Voltage eee E 100 Vde Range Accuracy gt gt 10 nF 10 uF lt 5 of reading 1 digit AC CAPACITANCE by capacitive bridge Measuring mode e by 1 kHz tone 1 1 Vpp between a b a Gnd b Gnd Range Resolution 0 1 to 3000 nF 0 1 nF ACCUPACY eee 1 of reading 1 nF C lt 500 nF 5 of reading 1 digit C gt 500 nF and lt 3000 nF LINE LENGTH BY CAPACITANCE Line length estimation as function of measured capacitance Line Capacitance setup 10 0 to 300 0 pF Length Unit Range Reso
10. ing Overvoltage Protection In Out connectors up to 150 Vdc 140 Vpp Reference Frequency accuracy 1 ppm within the operating temperature 2 ppm year Reference Level accuracy 0 025 within the operating temp 0 025 year CE mark EMC Directive 2004 108 CE 89 336 EEC Decree 2007 194 CISPR 11 ISO 14253 and CEI EN 61326 A1 A2 55011 61000 4 2 61000 4 3 61000 4 4 61000 4 6 61000 4 11 Special Features and Setup e Full remote control by USB and RS232 port interface e Data and Results Storage on internal flash memory e Data and Results Export vs PC and Pen Drive Signal Generator Sine output frequency range e base band from 20 Hz to 20 kHz e middle band from 20 kHz to 6 MHz e high band optional from 0 01 to 30 MHz Frequency Resolution 1 Hz up to 9 999999 MHz 10 Hz over 10 0 MHz Frequency setup mode manual on single frequency and steps mode on programmable band steps Output level eaereneee semen errr ner earner 60 20 dBm 150 Q 0 1 dB steps Output level accuracy 40 2 dB from 400 Hz to 20 kHz 600 Q 0 2 dB up to 2 MHz 0 3 dB up to 6 MHz 100 Q 1 dB up to 30 MHz 100 Q Balanced output impedances e base band 150 200 and 600 Q e middle band 100 110 120 135 150 and 1350 Q e high band 100 Q Unbalanced output impedances 50 and 75 Q by Banana BNC optiona
11. l adapter White Noise Generator 1kHz 6 MHz 74 144 dBm Hz 0 1 dB steps Signal amp Level Meter Frequency PANG 0 e e0eeeeeess from 20 Hz to 6 MHz two bands base version up to a 30 MHz with EBM 30 optional module Manual tuning resolution 1 Hz up to 9 999999 MHz 10 Hz over 10 0 MHz Level measurements mode absolute dBm or dBV or Volt or relative dBr Input WANIQS ssicsexcescetenesuedcewuase 120 12 dBm 100 Q 0 1 dB Resolution Level meter accuracy 0 2 dB from 400 Hz to 20 kHz 600 Q 0 2 dB up to 2 MHz 0 3 dB up to 6 MHz 100 Q 1 dB up to 30 MHz 100 Q Noise floor TX OFF 130 dBm Hz up to 30 MHz Frequency Meter sensitivity lt 50 dBm on wide band or selective mode Input impedances balanced e base band 150 200 600 and gt 10 KQ e middle band 100 110 120 135 150 Q and gt 10 KQ e high band 100 Q and gt 5 KQ Input impedances unbalanced 50 and 75 Q by Banana BNC adapter Noise filters cceeee e base band psophometric C Message 0 3 3 4 kHz 0 02 3 4 kHz 0 3 6 0 kHz 0 02 6 0 kHz 0 3 15 0 kHz 0 02 15 0 kHz 0 3 20 0 kHz 20 20 0 kHz 20 0 kHz flat e middle high band E F G and customs Selective filters notch e base band 200 Hz 20 kHz pass band and notch for S N D dB and test 10 Hz fo lt 200 Hz 5 fo
12. lution Accuracy 1 to 99999 Units m or ft 1 units as derived from measured capacitance RFL Resistance Fault Locator Loop resistance 000008 7 KQ maximum Fault resistance 20 MQ Accuracy of RTF 1M 0 1 of Loop resistance POTS module optional module installed on DMM module Dial Encoder Pulse 100ms off on ratio 40 60 DTMF std tones Ring Detect Range amp Meas Level 10 90 Vrms Frequency 15 70 Hz Ring Detector AC Load R7310 Q 2 in series 940nF 10 capacitor Ring current self limitation lt 15 mA peak safety fold back limited On Hook Break amp Make specs R 120 QO 2 I 100 mA Voffset 4 Vdc Automatic SELTest for line pre qualification With single ACT6000 Single End Tests on open lines using the pre configured masks for Voice ISDN HDSL E1 T1 SDSL G SHDSL ADSL ADSL2 and VDSL 1 2 2 or 4 Wire mode Metallics by DMM module AC DC Voltage Insulation AC DC Capacitance End Of Line by TDR Transmissives Noise local Return Loss Longitudinal Balance Loss FDR Insertion loss amp frequency response estimation Noise far end estimation SNR prediction ADSL ADSL2 and VDSL 1 2 Bit Rate prediction NEXT Automatic DELTest for line qualification With two ACT6000 Master Slave configuration for Double End Tests on lines using the pre configured masks