1. ee tM _ _ _ ph 14 49 in 368 0 mm mm 3 15 80mm Note Max panel thickness 5 mm Refer to the User Manual MANO883 for panel box information and a checklist of Note The tolerance to meet NEMA standards is 0 005 0 1 mm requirements 3 3 Panel Cut Out and Dimensions for HE ZX452 7 5 24 in 133mm tH _ _ _ gt 7 52 in 191 0 mm 2 19 55 5mm Note Max panel thickness 5 mm Refer to the User Manual MANO883 for panel box information and a checklist of requirements Note The tolerance to meet NEMA standards is 0 005 0 1 mm 7 15 2011 1037 MANO960 01 EN Specifications Installation 4 Connectors and Ports 4 1 ZX1152 Connectors and Ports ee ee et 5 n H Juk 70 0708 gt oG 3 ee LET veee pases Sse earn 4 2 ZX752 Connectors and Ports A Mounting Clip Location on the side of the ZX452 B Port 1 RS 232 C Port 3 RS 232 D Port 2 RS 485 E VGA Video Output Allows an external monitor to mirror the images on the ZX display must support native ZX resolution F Ethernet Port 2 Used for report I O Smart Rail Ethernet G Ethernet port 1 Used for Internet access Email FTP http H USB Ports Removable media is supported using these USB ports Up to two drives may be connected The first drive A must be installed on one of the
2. USB ports on the right top of ZX452 This is used for data log screen capture recipes program loading graphic object The second drive B must be plugged into the left bottom of ZX452 USB ports and is supported by the ladder copy rename and delete function only at this time l Audio Inputs and Outputs not supported with initial firmware J DC Power Input 10 to 30 Volts DC CAN Networking This 6 pin adapter supports 2 CAN networks CAN 1 supports programming peer to peer Z communications and ladder functions CAN 2 supports remote I O Smart Stix Smart Block and Smart Rail CSCAN An adapter board is included to provide 2 standard 5 pin CAN connections 7 15 2011 1037 MANO960 01 EN Specifications Installation 5 Port and Connector Pin outs 5 1 CAN Network Port and Wiring 6 Pin dual CAN connector CAN 1 Port Pin Assignments Pin Signal__ __ SignalDescription Direction Pp 1 Ve CAN 1Ground Black CAN 2 Ground Black 2 CN L CAN 2 Data Low Blue In Out 6 3CNH CAN 2 Data High White In Out 5 Pin CAN connector for Adapter Board CAN Connector Use the CAN Connector when using CSCAN network Torque rating 4 5 7 Lb In 0 50 0 78 N m NET Port Pin Assignments Signal Signal Description _ Direction _ In Out In Out E V NC Power Connector Power Up Connect to Earth Ground Apply 10 30 VDC Screen lights up with slight dela
3. with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation Radiated Emission Compliance For compliance requirement a ferrite Horner P N FBDOO6 supplied with the unit needs to be placed on the AC DC line with one loop All applicable codes and standards need to be followed in the installation of this product Adhere to the following safety precautions whenever any type of connection is made to the module Connect the safety earth ground on the power connector first before making any other connections When connecting to electric circuits or pulse initiating equipment open their related breakers Do not make connections to live power lines Make connections to the module first then connect to the circuit to be monitored Route power wires in a safe manner in accordance with good practice and local codes Wear proper personal protective equipment including safety glasses and insulated gloves when making connections to power circuits Ensure hands shoes and floor are dry before making any connection to a power line Make sure the unit is turned OFF before making connection to terminals Make sure all circuits are de energized before making connections Before each use inspect all cables for breaks or cracks in the insulatio
4. MANO960 01 EN Specifications Installation ZX Series OCS Controller Datasheet for HORNER HE ZX452 HE ZX752 and HE ZX1152 Required Power 3 0 A 24VDC 2 75A 24VDC 2 75A 24VDC Steady state ower Range Relative o Humidity 30 to 90 Non condensing Accuracy Operating 0 C to 45 C Temp Temp Display Type 7 WVGA TFT 800 nit typical 15 XGA TFT 350 nit typical 22 1080p TFT 300 nit typical Screen 800x480 1024x768 1920 x 1080 Resolutions emory L 130 MB 130 MB 130 MB emory Display Life 50 000 hours 25 C 5 virtual function keys 7 virtual function keys 7 virtual function keys Screens supported 1023 Weight 3lb 10z 1 39Kg 11lb 9oz 5 25Kg 18lb 30z 8 25Kg CE UL CG Qe 2 Ports 1 RS232 amp 1 RS485 3 Ports 2 B Ports 2 RS23281 RS485 amp 1 B Ports 2 RS23281 RS485 RS485 3 Ports 2 8 Ports 2 RS232 amp 1 RS485 amp 1 8 Ports 2 RS232 amp 1 RS485 RS485 Finernet 2 10 100 1000 1 dedicated for I O Remote I O Peer to Peer PC Programming USBA 2 High Speed 2 0 4 High Speed 2 0 4 High Speed 2 0 _ 2 Supports 2 USB Based Drives CAN 2 Ports 1 dedicated to I O Remote I O Peer to Peer PC Programming Remote I O SmartStix SmartBlock SmartMod or SmartRail VGA Video Out for Mirrored Display Mic Line IN Line Out Not Active with Current Firmware 7 15 2011 1037 MANO960 01 EN Specifications Installation 2 Installation 1 Prior to mou
5. ging screen captures program loading Drives larger than 2 gigabytes are supported and should be formatted with FAT 32 Future firmware updates will allow other peripherals to be connected to these ports 6 Technical Support For assistance and manual updates contact Technical Support at the following locations North America Europe Tel 317 916 4274 Tel 353 21 4321266 Fax 317 639 4279 Fax 353 21 4321826 Web http Awww heapg com Web http www horner apg com Email techsppt heapg com Email tech support horner apg com 1037 MANO960 01 EN Specifications Installation 7 Safety When found on the product the following symbols specify arning Electrical arning Consult Shock Hazard user documentation This equipment is suitable for use in Class Division 2 Groups A B C and D or Non hazardous locations only WARNING EXPLOSION HAZARD Do not disconnect equipment unless power has been switched off or the area is Known to be non hazardous AVERTISSEMENT RISQUE D EXPLOSION AVANT DE DECONNECTOR L EQUIPMENT COUPER LE COURANT OU S ASSURER QUE L EMPLACEMENT EST DESIGNE NON DANGEREUX WARNING To avoid the risk of electric shock or burns always connect the safety or earth ground before making any other connections WARNING To reduce the risk of fire electrical shock or physical injury it is strongly recommended to fuse the voltage measurement inputs Be sure to locate fuses as close t
6. n Replace immediately if defective No part of this publication may be reproduced without the prior agreement and written permission of Horner APG Inc Information in this document is subject to change without notice 7 15 2011 1037
7. nting observe requirements for the panel layout design and spacing clearances in the OCS ZX Series Manual MANOxxx 2 Cut the host panel 3 Insert the OCS through the panel cutout from the front The gasket material needs to be between the host panel and the OCS Caution Do not force the OCS into the panel cutout An incorrectly sized panel cutout can damage the touch screen 4 Install and tighten the mounting clips provided with the OCS until the gasket material forms a tight seal 5 Connect cables as needed such as communications programming power and CsCAN cables to the ports using the provided connectors 6 Begin configuration procedures Note The ZX1152 and ZX752 also supports standard VESA 75x75 or 100x100 mounting for wall or arm mounting The ZX452 supports the VESA 75x75 mounting pattern 4mm screws should be used and are typically supplied with the mount tee 3 1 Panel Cut Out and Dimensions for HE ZX1152 22 13 74 349mm 11 81 in 300mm Ito A 21 02 534mm 19 84 in 504mm lt gt Note Max panel thickness 5 mm Refer to the User Manual MAN0883 for panel box information and a checklist of Note The tolerance to meet NEMA standards is 0 005 0 1 mm requirements 7 15 2011 1037 MANO960 01 EN Specifications Installation 3 2 Panel Cut Out and Dimensions for HE ZX752 15 12 60 320mm 11 50 in 292mm
8. o the source as possible WARNING Replace fuse with the same type and rating to provide protection against risk of fire and shock hazards WARNING In the event of repeated failure do not replace the fuse again as a repeated failure indicates a defective condition that will not clear by replacing the fuse WARNING EXPLOSION HAZARD Substitution of components may impair suitability for Class Division 2 AVERTISSEMENT RISQUE D EXPLOSION LA SUBSTITUTION DE COMPOSANTS PEUT RENDRE CE MATERIAL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE 1 DIVISION 2 WARNING The USB parts are for operational maintenance only Do not leave permanently connected unless area is known to be non hazardous WARNING EXPLOSION HAZARD BATTERIES MUST ONLY BE CHANGED IN AN AREA KNOWN TO BE NON HAZARDOUS AVERTISSEMENT RISQUE D EXPLOSION AFIN D EVITER TOUT RISQUE D EXPLOSION S ASSURER QUE L EMPLACEMENT EST DESIGNE NON DANGEREUX AVANT DE CHANGER LA BATTERIE WARNING Battery May Explode If Mistreated Do Not Recharge Disassemble or Dispose Of In Fire WARNING Only qualified electrical personnel familiar with the construction and operation of this equipment and the hazards involved should install adjust operate or service this equipment Read and understand this manual and other applicable manuals in their entirety before proceeding Failure to observe this precaution could result in severe bodily injury or loss of life This device complies
9. y Torque rating 4 5 7 Lb In 0 50 0 78 N m Pin Signal Description Input Power Supply Ground Input Power Supply Voltage 7 15 2011 5 3 Ethernet Port Speeds 10 BaseT Ethernet 10 Mbps na 100 BaseTx Fast Ethernet 100 Mbps 1000 Base Tx Fast Ethernet 1000 Mbps Auto Negotiation 10 100 1000 Mbps and Half Full Duplex Connector Type Shielded RJ 45 ree eee CATS or better UTP Auto MDI MDI X Serial Ports 1 2 and 3 gnments RS 232 Signal Signal Description CD Carrier Detect DTR Data Terminal Ready GND Ground DSR _ DataSetReady RTS _ReadytoSend CTS _CleartoSend RI Ring Indicate Serial Port 2 Pin Assignments RS 485 Signal __ Signal Description _ Direction NC _ DoNotConmect NC DoNo tConect GND Ground S DSR _ DataSetReady S Ss Ready to Send Clear to Send R O Ring Indicate 5 5 VGA Port The VGA port allows the items displayed on the internal display to be mirrored to an external display or projects The connector uses standard analog VGA signaling and should work with a variety of monitors displays and projects The external display should support the native resolution of the ZX unit 5 6 USB Ports The ZX units have two ZX351 or four ZX751 amp ZX1151 standard USB ports supporting high speed USB 2 0 These ports will support external drives for data storage such as data log