Home
IVM Client Benutzerhandbuch - Siemens Building Technologies
Contents
1. The system overview with all its features and components is configured in IVM Config More information can be found in the IVM Config Configuration Manual Fig 24 Site plans System overview section System overview Device icons are used in the system overview to represent the devices used by the site e g matrix SISTORE SX The device icons visualize the state of the device in order or faulty Depending on the configuration a device icon may represent either one or several devices of a type The following devices are supported in the system overview e SISTORE SX CX e SISTORE AX MX e Video matrix switcher e O Server e TELEMAT 46 Siemens Building Technologies Fire Safety amp Security Products 03 2009 System overview 7 1 Displaying the system overview There are two possible ways to display the system overview e Display the system overview via the menu e Display the system overview via the plan overview Prerequisite You have already configured a system overview with IVM Config More information can be found in the IVM Config Configuration Manual Display the system overview via the menu 1 Select the menu sequence File gt Load plan gt System overview OR Select System overview in the Maps tab in the navigation zone see Section 3 4 1 Plan overview Maps gt The system overview is displayed in the Site plans System overview section Display the system overview via the plan
2. ccccccccccesseeeeeeeeeeeeeessaeeeeeeesenaeees 44 Closing site plans 222uu00s22000nnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnneenennnn 45 System OVEIVIE W riii 46 Displaying the system overview eanseenennsnnsnennennnennnnnnnnnnnnnnnnnnnne nennen 47 Visualizing details and malfunctions of individual devices 47 Adding the system overview to the faVOULiteS cccccccceeseeeeeeeeeeeeeeees 50 Gamera Saunaan ee 51 Camera States and representation ccccccccsssssseeeeeeeeeeeseeeeeeeeeseaaaeeees 51 Activating Camera on output devices usssnesneneesnnennnnnennnnnnnnnnnnnnnnen nn 52 Adding Cameras to the favourites uuuusssnesnnneennnennnnnnnnennnnnnennennnnne nn 53 Gamera COMO leis sa aeration a eet ie nets 54 Controlling cameras via IVM CIiOnt cccccsesseseeeeeeeceeeeeeeeeeeeeessaaeeeees 54 Controlling cameras via SISTORE MX RemoteView ccccceeees 55 Live images een 57 Displaying live IMAQES ccccccseseeccceseecsesseecceseeecsaueeecseuseesseusesssaeeesees 58 Saving live images ana ne Bu 60 GISING IVe Image 61 PANUNG IYS IMAGES an ne En 62 Displaying removing video information us 4 444444nnn nenn nnnnnnnne nn 62 Displaying live image in full screen mode ccccceseeeeeeeeeeeseceeeeaeeeeess 64 Closing live images in the device OVEFVIEW ccccccceeeeeseeeeeeeeeeseeaeeees 65 SEBECH 2 enable 66 S
3. 03 2009 Search gt The following window opens E 24 0401 0001A EA Video Inp GA Video np X Video Ing EN video inp BE cx 04080004 B ce 04020031 B ce 04020002 Sx 06 SU PT Eing EN video Inp video Inp Video Ing Sx 08 ae Sr sf 4 m m O search Yk From 22 03 2005 02 45 19 To Alcameras Ta Rule Comment IE O Dae Timespan _ Gelectedcamera Rue Taq J Comment Ivitag 22082005 09 51 52 000OE PTZ Eingang SISTORE 8 Standard Regel Wor U User 21 03 2005 16 52 15 08 00 24 Wideo Input 1 8 03 Tunnel Bererstatup 2103 2005 16 52 14 08 00 27 ideo Input 5x05 Tunnel ServerrStartUp Fig 38 SISTORE SX CX search 10 1 2 Starting anew SISTORE SX CX search 1 Click the icon g Start search in the left section of the screen gt A new search is started 10 1 3 Adding removing columns in the SISTORE SX CX hit list 1 Right click on a column header gt The following context menu opens O Server name mir Date O Start time O Stop time Time span Selected camera O No cameras Rule Tag Comment O WM alarm ID 2 Mark or unmark the corresponding checkbox 67 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Search gt The corresponding column will added or removed IVM alarm ID Database ID displayed in the IVM Config Edit alarm properties Organiz
4. Name Name of the alarm e Comment Description of the alarm e Processing Instructions for the user Type Type of alarm e Status Status of the alarm e Priority Priority of the alarm Device Device where the alarm occurred Contact ID of the contact where the alarm occurred The alarm ID the name comment processing type priority device and contact are defined in the IVM Config More information can be found in the IVM Config Configuration Manual 16 3 1 Refresh alarm log 1 Right click on the alarm log gt The following context menu opens Alarmbilder Ausgew hlte Alarme sichern Alle Alarme sichern Report 2 Select Refresh list in the context menu gt The alarm log is refreshed 102 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Alarm list message list and logbooks 16 3 2 Sort alarms The alarm log can be sorted by the Date Name and Calendar columns 1 Click on the appropriate column header in the alarm log gt The alarms will be sorted in ascending order gt This is indicated by a ascending in the selected column header 2 In order to sort the alarms in descending order click on the column header once more gt The alarms will be sorted in descending order gt This is indicated by a V descending in the selected column header 16 3 3 Alarm log search The alarm log can be filtered using the Date from to and or N
5. gt The context menu of the MX camera opens Open archive Stan record Open camera Close all camera 2 Select Open camera gt The live image of the MX camera is displayed together with the RemoteView control elements see Fig 32 3 Click on the live image gt The live image is displayed with a yellow surround gt The camera control is activated Mx_100_01_Kam04 7713707 19 38 25 BE Camera control SISTORE MX RemoteView Fig 32 55 Siemens Building Technologies 03 2009 Fire Safety amp Security Products Cameras 56 Siemens Building Technologies Fire Safety amp Security Products Virtual joystick Position buttons Buttons for changing camera positions Button for automatic position cycle Drop down list for position selection Virtual joystick Function Key Motion left right up down up right down Travel keys right up left down left arrows Zoom in out P Focus far 0 near 00 Position buttons The first 5 camera positions you have configured in SISTORE MX can be selected using the buttons Pos 1 to Pos 5 Buttons for changing camera positions You can change the camera positions you have configured in SISTORE MX using these buttons Drop down list for position selection You can move the cameras to any position you have configured max 32 by selecting it from the drop down list Button
6. 1 To setthe filter Date click on the calendar symbols next to the from and to input fields and select the appropriate dates and times In the Event input field you can search using wildcards il replaces individual characters replaces partial string 2 To set the filter Event enter the appropriate event in the Event input field 3 Click the icon Search gt The log search is performed using the currently set filters Reset filters You can reset all search filters for instance to start anew search 1 Click the icon Reset filter gt The filters are reset 16 4 3 Save events il The events are saved to the directory CEVIS IVM_Client Log by default 1 Select the event s you would like to save 2 Right click on an event that you have selected gt The following context menu opens feds ea rat cana a eat Br SE eee ee EA VE SEIEL ed eve as Save all events 3 Select one of the following actions from the context menu Save selected events The selected events will be saved Save all events All events will be saved gt The Select path dialog opens see Fig 57 4 Ifthe events are to be saved to somewhere other than in the default directory select the desired directory 5 Click Select gt The events are saved 106 Siemens Building Technologies Fire Safety amp Security Products 03 2009 User profiles 17 User profiles il il Siemens Building
7. Software description 3 4 Navigation zone 16 Siemens Building Technologies Fire Safety amp Security Products Maps Favorites HE Product plan WT System overview P HE VKS Gd KAMERA_1 GW KAMERA_ E KAMERA_S GW KAMERA_4 ld KAMERA_S E KAMERA_B GW KAMERA_ Gd KAMERA_S E KAMERA_I GW KAMERA_10 Gd KAMERA_11 GW KAMERA 12 GW KAMERA_13 GW KAMERA_14 ld KAMERA 15 Gd KAMERA_16 Fig 3 Program window Navigation zone In the navigation zone you can choose between three different views of the system These overviews can be found in the following tabs e Maps The Maps tab displays the available site plans and the associated configured cameras e Devices The Devices tab displays the configured devices and the associated connected inputs and outputs e Favorites The Favorites tab displays user defined favourites site plans cameras and monitors Show hide tabs 1 Right click on a tab in the navigation zone gt The following context menu opens Devices Favorites 2 Select a tab that you wish to show or hide gt The tab is shown or hidden 03 2009 Software description 3 4 1 Plan overview Maps Maps Devices Favorites gt Product plan System overview i VKS Led KAMERA_1 Ld KAMERA 2 Led KAMERA J Led KAMERA 4 Lad KAMERA_S led KAMERA_H Led KAMERA T Led KAMERA_S Ld KAMERA_Y Ld KAMERA 10 Gad KAMERA_11 Ged KAMERA 12 Gad KAMERA 13 Ged KAMERA_T4 Gad KAMERA
8. 60 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Live images gt The following dialog box opens Suchen in a A EE O Log J resources Dateityp JPEG image files jpg z Save Abbrechen Fig 36 JPEG Editor Save image 4 Select a directory to which you wish to save the live image 5 Enter a file name in the File name text field 6 Click Save gt The live image is saved 9 3 Closing live image 4 Right click on the live image you wish to close gt The context menu which opens depends on the type of camera Save Print Enter full screen mode 5 Select the menu item Close gt The live image of the camera is closed 61 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Live images 9 4 Printing live images 1 _ Right click on the live image you wish to print gt The context menu which opens depends on the type of camera Enter full screen mode 2 Select Save Print gt The JPEG Editor dialog opens see Fig 35 3 Click on Print 4 Inthe printer dialog click OK gt The live image will be printed 9 5 Displaying removing video information Displaying video information 1 Right click on a live image gt The context menu which opens depends on the type of camera Close Save Print Enter full screen mode Video Information U Format U Date Time U Bit rate O Im
9. Absolute activation Define Delete es Display 38 Edit Relative activation Setup Signal words Site plan Site plans 112 Siemens Building Technologies Fire Safety amp Security Products Software container Hide Layout Open live image Software monitors Acknowledge alarm Assigning Closing live images Full screen mode Positioning Restoring live image Show Starting the IVM Client State of output device System information System overview System requirements T Tab Device overview Favorites Plan overview Target readers Toolbar Tree structure Trouble shooting U User profiles User related profile Workstation related profile V View W Work safety information 03 2009 Issued by Siemens Building Technologies Fire amp Security Products GmbH amp Co oHG D 76181 Karlsruhe www buildingtechnologies siemens com Document no A24205 A336 B415 Edition 18 03 2009 2009 Copyright by Siemens Building Technologies Data and design subject to change without notice Supply subject to availability Printed in the Federal Republic of Germany on environment friendly chlorine free paper
10. Leaving full screen mode 1 Right click on the live image in full screen mode gt The context menu which opens depends on the type of camera Close Save Print 2 Select Leave full screen mode gt The live image is displayed again in normal screen mode gt Full screen mode is closed 64 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Live images 9 7 Closing live images in the device overview In the device overview you can close individual live images or all live images simultaneously Close individual live image 1 Right click on the camera icon whose live image you wish to close gt The context menu which opens depends on the type of camera Open archive Stop record Close all Camera 2 Select the menu item Close camera gt The live image of the camera is closed For further information please refer to the corresponding SISTORE SX CX Client SISTORE MX and SISTORE AX user manuals Close all cameras 1 Right click on a camera whose live image is displayed gt The context menu which opens depends on the type of camera Open archive Stop record Close camera 2 Select Close all cameras gt The live images of all cameras are closed 65 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Search 10 Search 10 1 SISTORE SX CX search 10 1 1 Starting SISTORE SX CX search il il 66 Siemens Building Tech
11. OR Right click on a blank software monitor and select Live image position 83 03 2009 Software monitors O Monitor 1 Monitor 2 O Fit to screen O Topleft O Top O Topright Left Center O Right O Bottomleft Select layout O Bottom Select software monitor Bottom right O Manually Show window Close Ive images Click on the desired monitor Right click on a software monitor Select Live image position 2 3 4 3 Click Fit to screen gt The software monitors are displayed in full screen mode on the additional monitor 6 To exit full screen mode select any other live image position see Section 13 9 Positioning software monitors gt Full screen mode is now terminated 13 8 Assigning software monitors 1 Right click on a blank software monitor il It is only possible to select software monitors which are configured on the server 2 Use Select software monitor to select the monitor to be moved to the grid cell gt The software monitor is now assigned 84 Siemens Building Technologies Fire Safety amp Security Products 03 2009 13 9 Positioning software monitors Software monitors There are different options for positioning the software monitors on the screen 1 Select Live player position from the context menu 2 Select a predefined position e g top left See the figure below Top lett Top Top right Left Center Righ
12. Date Time and date of occurrence disappearance of the message Message The following messages can appear in the message list Message Server Mode Examples for the occurrence of the message Normal operating mode Demo Mode No licence Licence exceeded Video signal loss Camera failure No connection to the camera Communication connection has failed Connection between the devices MX CX has failed Failed to connect camera x to output x Devices are configured differently Digital video image CX is switched to analog output VKS Camera x is already connected with user x The camera has been activated by another user Error moving camera x in direction x The camera is being controlled by another user Error zooming in out camera x The camera is being controlled by another user Error focusing far near camera x The camera is being controlled by another user 99 03 2009 Alarm list message list and logbooks Message Examples for the occurrence of the message Error stopping camera The camera is being controlled by another user Error setting position x of camera The camera is being controlled by another user X Failed to navigate in OSD menu The camera is being controlled by another user of camera x for direction x Source Source of the message e g device user State The following messages can appear in the message list State Alloca
13. e g bird in front of the lens insects on the lens False alarm e g rain snow shadow When the alarm messages have been classified see Section 16 1 2 Acknowledging and classifying EDS and ODR alarms it is possible to generate reports of nuisance alarms and false alarms see Section 16 3 5 Generate report of nuisance alarms or false alarms 5 2 1 Activating deactivating classification of EDS and ODR alarms 1 Select the menu sequence Tools gt Options gt The following dialog box opens Alarm configuration Classify motion alarms EDSioIDR Huisance alarm False alarm bird in front of lens shadow Insects in front of lens snow Remove Add Remove OK Cancel Fig 12 Classification of EDS alarms 28 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 2 To activate the classification of EDS and ODR alarms mark the checkbox Classify motion alarms EDS ODR 3 To deactivate the classification of EDS alarms unmark the checkbox Classify motion alarms EDS ODR 4 Click OK gt The classification of EDS and ODR alarms is activated or deactivated 5 2 2 Defining a new category for nuisance alarms and false alarms 1 Select the menu sequence Tools gt Options gt The Options dialog opens see Fig 12 2 Click Add gt The following dialog box opens 12 Provide a reason for new false alarm po ok Abbrechen Fig 13
14. 18 03 2008 There is no entry in the last list box which means that this filter is inactive 1 Click on the arrow in the first list box 2 Select a filter For the filters Status and Type the available operators are equals und lt gt not equals 3 Select the operator you want to use to limit the search in the second drop down list In the Date filter input box you can enter the date time as text in the date format of the language you selected at login e g English dd MM yyyy hh mm ss or you can select a date and time from a calendar selection box see below Search using the date 4 Enter a value in the text field 5 Click the icon n Search gt The expert search is performed using the filters you have set gt The results of the search are displayed in the log Search using the date 1 Select either the Event log or the Alarm log tab 2 Click on the arrow in the first list box 3 Select the filter Date gt A calendar icon appears next to the text field 4 Select the operator you want to use to limit the search in the second drop down list il For the filters Status and Type the available operators are equals und lt gt not equals Siemens Building Technologies Fire Safety amp Security Products 5 Click on the calendar icon gt A calendar opens 93 03 2009 Search July 2007 gt Mon Tue Wed Thu Fri sat Sun 1 ab 7 5 121314 15 19 20 21 22 26 27 20
15. 29 Fig 52 Calendar In the Date filter input box you can enter the date time as text in the date format of the language you selected at login e g English dd MM yyyy hh mm ss 6 Select the month and year for the start of the search using the arrows d and P inthe upper section of the calendar r 7 Select the time using the arrow symbols 8 Select a day from the calendar gt The selected date is entered in the text field 9 Click the icon Q Search gt The expert search is performed using the currently set filters gt The results of the search are displayed in the log 15 2 3 Sorting search results il By default the results of the search are displayed in ascending date order Alarms can be sorted according to the columns Date Name and Comment Event can be sorted according to the columns Event and Date 1 Click on the appropriate column header in the log gt The alarms will be sorted in ascending order gt This is indicated by a ascending in the selected column header 2 In order to sort the alarms in descending order click on the column header once more gt The alarms will be sorted in descending order gt This is indicated by a V descending in the selected column header 15 2 4 Filter reset You can reset all search filters for instance to start anew search 1 Clicktheicon Reset filter gt All filters are reset 94 Siemens Building Technologies
16. Configuring sequences Select sequence 2 If only the sequences of a particular plan are to be displayed select this plan in the Restrict choice drop down list gt All sequences with at least one camera of the selected plan will be displayed 3 Ifall sequences are to be displayed select all plans from the drop down list gt All sequences that have been configured will be displayed regardless of the plans they are associated with 5 4 2 Define anew sequence Prerequisite The operator has the right Configure sequences More information can be found in the IVM Config Configuration Manual 1 Select the menu sequence Tools gt Sequences gt The Select sequence dialog opens see Fig 17 2 Click New 35 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 36 Siemens Building Technologies Fire Safety amp Security Products gt The following dialog box opens Comment Fig 18 Configuring sequences New sequence Enter the name of the sequence If desired enter a comment on the sequence in the Comment text field Right click on the Output Device box and select the desired output device OR Use drag amp drop to drag the selected output device from the monitor bar or the device overview to the Output Device box Right click on the appropriate field of the table and select the desired cameras and groups of the sequence OR Use drag amp dr
17. Cx 0 System pollingservice 150312005 12 07 34 Going VES_FAILURE with videomatrix 54 06 System pollingservice 18 03 2005 12 04 55 Coming VES FAILURE with videomatrix C System pollingservice 150312005 12 03 17 Coming ES_ FAILURE with videomatriz Sx System pollingservice 18 03 2005 11 53 05 Going VES _FAILURE with videomatrix Cx 0 System pollingservice tL Hii i Bu ulaullatuiahle I 5 with wirle ors Fig 60 Event log The event log comprises the following columns Date Date when the event occurred Event Description of the event Type Type of event e Source Event trigger e Processing Instructions for the user 16 4 1 Sort events The event log can be sorted by the Event and Date columns 1 Click on the appropriate column header in the event log gt The events will be sorted in ascending order gt This is indicated by a ascending in the selected column header 2 In order to sort the events in descending order click on the column header once more gt The events will be sorted in descending order gt This is indicated by a V descending in the selected column header 105 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Alarm list message list and logbooks 16 4 2 Event log search The event log can be filtered using the Date from to and or Event input fields See the figure below Date from g to E Event ss il The filters are ANDed
18. Database driver providing a programming interface API Using this interface the programmer can develop his application independent of the database server used With this technology it is possible to embed data from any application into a database system OVERLAY Using this technique the video image is always displayed in a window on the Windows operator interface The Frame Grabber inserts the video image in the image generated by the computer s graphics board this takes place electronically in real time and without loading the processor QCIF Image format with a resolution of 176 horizontal pixels and 144 vertical pixels and a frame rate of 30 images per second RAM Random Access Memory ROM Read Only Memory SCSI High performance interface for connection of devices which transmit large data volumes with high speed e g hard disk drives scanners etc SCU SIMATRIX Camera Control Unit SIMATRIX Video matrix SISCAN Fast digital camera switcher SISTORE Digital video recorder TELEMAT Video sensor system for monitoring and evaluating video signals TELSCAN System for transmission of video and audio data over analog telecommunication networks ISDN or digital data networks VGA IBM Video Graphics Adapter VKS Video matrix 110 Siemens Building Technologies Fire Safety amp Security Products 03 2009 20 Index Index A About IVM Alarm classification Alarm list Alarm log Filter alarms Refresh Save alarms 104 Sor
19. Keep the CD between 5 and 55 C Do not store the CD in excessively dusty places Do not keep the CD close to sources of magnetic radiation Protect the CD from moisture Protect the CD from direct sunlight 2 3 Meaning of the written warning notices The severity of a hazard is indicated by the following written warning notices Signal word Type of risk CAUTION There is a risk of minor injuries or damage to property IMPORTANT Malfunctioning may result 2 4 Meaning of the hazard symbols The nature of the hazard is indicated by icons Caution Dangerous area Caution Dangerous electrical voltage 13 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Software description 3 Software description Program window 1 Menu bar Inthe menu bar you can access the various menus si g GA KAMERA_T KAMERAS KAMERA 49 Ge KAMERA_10 KAMERA_11 Gd KAMERA 12 GN KAMERA_13 CU Duals 14 Cog KAMERA 16 ma Se Overview 80000000 Gd KAMERA 10 KAMERA_11 Gad KAMERA 12 E KAMERA 13 TOR_2 MOMITOR_3 MOKITOR_4 Video Outnutt Video Quthut z a KAMERA_15 E KAMERA IE Outputpanel Favorites Alarms aed Alarm log Event log Ct oem A oenas KE er San aaa B admin localhost temporarily operated localhost temporarily operated Fig 2 IVM Client application window Toolbar In the toolbar you can trigger various predefined actions S
20. Select the sequence you would like to delete 3 Click on Delete sequence gt The selected sequence is now deleted 39 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Site plans 6 Site plans il 40 Siemens Building Technologies Fire Safety amp Security Products The site plan properties such as the background image and components e g cameras are configured in the IVM Config More information can be found in the IVM Config Configuration Manual Bank Fig 20 Site plans System overview section The currently loaded site plans and the system overview are depicted in the site plans section The tabs at the lower edge of the site plan section serve to navigate between loaded plans quickly and efficiently The main control functions such as the switching or cancellation of video connections are listed on the site plans and in the monitor bar below the plans Most of the functions are carried out using the context menus of the active components cameras multifunction icons or monitors or by drag amp drop activation of video connections Context menus of the site plans Groups see Section 5 3 Configuring camera groups Sequences see Section 5 4 Configuring sequences Load plan see Section 6 1 Opening site plans 03 2009 Site plans 6 1 Opening site plans il There are two possible ways to open site plans e Open site plans via the menu e Op
21. Technologies Fire Safety amp Security Products 03 2009 Search 15 Search There are two options for searching for alarms messages and events e Log search see Section 15 1 Log search e Expert search see Section 15 2 Expert search 15 1 Log search Log search can be performed in the alarm and event logs in the Alarms Messages Logs section of the IVM Client program window Alarms I Messages Alarm log Eventlog D Ee Date from Hal even O Daten Event ype Source Processing 11 22007 164A 04 ser admin logged in Service Capservice 11 2007 18 43 37 ser admin logged Service sessionsemice Tr 22007 18 43 37 session service stopped Service sessionsemice 11 32007 16 36 57 ser admin logged in Service Capservice 11 32007 16 36 19 ser admin logged Service sessionsemice 11 32007 16 36 19 Session service stopped Service sessionsemice 11 22007 15 59 19 User admin logged in Service Capservice 11 22007 15 59 01 Coming VES FAILURE with videomatrix Vl System pollingsemice 11 22007 15 58 59 Coming VIDEO SIGNAL LOST on camer System alarmservice 11 2007 16 56 59 Coming VIDEO SIGNAL LOST on camer System alarmservice 11 22007 1558 59 Gong VIDEO SIGNAL LOST on camera System alarmservice Fig 50 Log search Event log You can use the log search function to search for alarms and events see Section 16 3 3 Alarm log search and Section 16 4 2 Event log search 91 Siemens Building Technologies Fire Safety amp S
22. Version MWM Client gt The licence and system information is displayed Lu gt F oo ee foo T le o About IVM System information 21 03 2009 Operational setup 4 Operational setup 4 1 System requirements for the client PC Processor Dual core processor RAM 1 GB Available hard drive capacity 10 GB Operating system Windows XP Windows XP SP2 or Windows Vista Graphics card With support for DirectX 8 or later version Screen resolution Min 1024 x 768 pixels Colour depth 16 bit or 32 bit 24 bit not supported Additional information can be found in the Readme file in the directory D Cevis 4 2 Starting the IVM Client Prerequisite Dongle wibu dongle IVM will run for 8 hours without a dongle There are several possibilities to start the IVM Client Starting IVM Client as an applet See Section 4 2 2 Starting IVM Client as an applet OR e Starting IVM Client as an application See Section 4 2 3 Starting IVM Client as an application il When launched as an application IVM Client offers a wider range of functions 22 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Operational setup 4 2 1 Applet settings il This description refers to Java version 1 5 The Control Panel of other Java versions may differ from the description below In order to use the applet make the following
23. amp Co oHG Microsoft is a registered trademark and Windows a trademark of Microsoft Corporation All other product or company names mentioned in this document are trademarks or registered trademarks of their respective owners and are used only for purposes of identification or description Contacting us If you have questions or suggestions regarding the product or this documentation please contact our Customer Support Center Intranet Customer Support Center Internet Worldwide contacts Email fs support sbt siemens com Tel 49 89 9221 8000 Training courses Siemens Fire amp Security Products provides training courses for all products Contents Siemens Building Technologies Fire Safety amp Security Products 1 1 1 2 1 3 2 1 2 2 2 2 1 2 2 2 2 2 3 2 2 4 2 2 5 2 3 2 4 3 1 3 2 3 3 3 4 3 4 1 3 4 2 3 4 3 3 5 3 6 4 1 4 2 4 2 1 4 2 2 4 2 3 4 3 4 4 4 5 9 1 5 2 5 2 1 5 2 2 9 2 3 5 3 5 3 1 5 3 2 5 3 3 5 3 4 9 3 9 5 4 5 4 1 5 4 2 5 4 3 5 4 4 54 5 Description OT TUNClIONS uu nei ee an 9 General UNCION Sease aaa 9 FUNCTIONS IVM SISTORE sushi 10 Operalingrpringiplessiinsn ee een 11 Salei nahen 12 Target readers NE 12 YYOrK Safety INIOTMAlION east 12 MANAGER en 12 Transporte E 12 Operational setup uu00022000000000eennnnnnnnnnnnennnnnnnnnnnnnnnnnnnennnnnnne nennen 12 Data loss aller UBdae aaa 13 TO Ce areca er hc ne ee ee 13 Meaning of the written
24. by drag amp drop Prerequisites The operator has the right Configure groups More information can be found in the IVM Config Configuration Manual The IVM Server workstation is already assigned monitors More information can be found in the IVM Config Configuration Manual One software monitor is configured for each camera At least one camera group has been defined Absolute activation of camera groups Camera groups can be activated absolutely The video images of the selected camera group are then displayed on the monitors software monitors assigned to the camera group 1 Select the menu sequence Tools gt Groups gt The Select group dialog opens see Fig 14 2 Select the camera group you wish to display 3 Click on Connect gt The video images are now displayed on the monitors that are assigned to the group Relative activation of camera groups via context menu Camera groups can be activated relatively via the context menu The video images of the selected camera group are then displayed on the selected monitor software monitor and the subsequent monitors software monitors 1 Select the menu sequence Tools gt Groups gt The Select group dialog opens see Fig 14 2 Right click on the group you wish to activate gt The context menu of the group opens n MONITOR_2 N M ONITOR_3 3 Select the monitor software monitor on which the first video image of the group is to be displayed gt The video
25. overview 1 Click on the system overview in the Maps tab gt The system overview is displayed in the Site plans System overview section see Fig 2 7 2 Visualizing details and malfunctions of individual devices 1 Click on the desired device in the system overview gt The following window opens SISTORE 54 oA O6 Connection 5 06 1 2050 DateTime Component Fig 25 Details of SISTORE SX 47 Siemens Building Technologies Fire Safety amp Security Products 03 2009 System overview The device structure device and its sub components is displayed in the left section of the window The device icons visualize the different states of the devices Green There is no malfunction Red There is a malfunction il The faulty sub component of the device where the malfunction occurred is crossed out in the device tree 2 Click on the desired device or the sub component of the device in the left section of the window gt The details of the device or sub component are displayed in the right section of the window gt In the case of a malfunction or failure of the device or one of its sub components these will be listed in the right section of the window il As soon as a fault has been eliminated it is automatically removed from the list The device windows of the individual device types are shown in the following x SIMATRIE SIMATRIX z 2 16 4 Digitallnputs j Connection Rod
26. saved gt The following context menu opens Suchen n 988 Dateiname jMessage 20070 923 10 Dateityp Alle Dateien select Abbrechen Fig 57 Message list Save messages il The message are saved to the directory CEVIS IVM_Client Log by default 4 Ifthe messages are to be saved to somewhere other than in the default directory select the desired directory 5 Click Select gt The messages are saved 101 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Alarm list message list and logbooks 16 3 Alarm log The alarm log see Fig 58 provides a list of all the alarms that have occurred Every change of state of an alarm is displayed in a separate line of the log Alarms Messages Alarm log Eventlog E D Ee Date from to e Mare Comment Status m Date A slam ID Mame Comment Processing Tvpe Status Priori Device Contact 1903 72005 12 05 19 1 Alarm 1 Internal Inactive ackn 100 TELEMAT_3 190372005 12 05 17 2 Alarm 2 Internal Inactive ackn 100 TELEMAT_3 15903 2005 12 08 17 3 Alarm 23 Internal Inactive ackn 100 TELEMAT_3 1510372005 12 07 45 1 Alarm _1 Internal Active 100 TELEMAT_3 150372005 12 0747 2 Alarm 2 Internal Active 100 TELEMAT_3 Ar I Ir Soren nterna Active C WLS BJ AA 2 Fig 58 Alarm log The alarm log comprises the following columns e Date Date of occurrence disappearance of the alarm e Alarm ID Database ID of the alarm
27. settings 1 Select Start gt Settings gt Control Panel in the Windows start menu gt The Control Panel window will open 2 Double click on Java gt The Java Control Panel dialog box will open Select the General tab Click on Settings in the Temporary Internet Files section Untick the checkbox Activate caching Select the Java tab Inthe Java Applet Runtime Settings area click View NS oS gt Enter the Java runtime parameter Xmx256M gt The applet settings are now made 4 2 2 Starting IVM Client as an applet Siemens Building Technologies Fire Safety amp Security Products Prerequisites The applet settings have been made See Section 4 2 1 Applet settings Version 1 5 0_06 or higher of the Java Runtime Environment JRE is installed on the client PC Open the Internet Explorer 2 Enter the following address htto Server ivm ivmweb 3 Replace Server by the name or IP address of the IVM server IYM Web Client Microsoft Internet Explorer Fie Edit View Favorites Tools Help Back es x a A e Search 7 Favorites a Address http 192 168 0 80siveoifivrweby Fig 8 IVM as an applet Internet Explorer address 4 Press the lt Enter gt key gt An error message indicates that you are using an older version of the JRE Install a new version of JRE see Section 4 3 Installing Java Runtime Environment 23 03 2009 Operational setup gt The following dialog box opens Wa
28. software monitor is displayed in pink gt The live alarm images are acknowledged and closed 13 12 Restoring live alarm images Live images that were closed manually during an alarm can be reopened when needed 1 Right click on the software monitor 2 Select Show live image Select layout Live images position Close ive images Acknowledge alarm Show lire im gt The live image is opened again 86 Siemens Building Technologies Fire Safety amp Security Products 03 2009 External programs 14 External programs 14 1 Starting SISTORE SX CX client 1 Select the menu sequence Tools gt SISTORE SX CX Client gt The following dialog box opens 1 Showroom CAS Showroom Cadi Showroom OK Cancel Fig 47 External programs Start SISTORE SX CX Client 2 Select the devices to which a connection is to be established 3 Click OK gt The integrated SISTORE SX CX Client is launched without filter 87 Siemens Building Technologies Fire Safety amp Security Products 03 2009 External programs EJ SISTORE SX CX E Video lriput i 16 07 2007 16 07 06 oF 9 02 yM CH4 02 gt en L E Video Input 1 EN video Input Er B 6 Ge EE YM CX4 02 ii O DIE gt o 088 Search Y From 18 07 2007 15 36 08 Toi f n o ag Rule Comment Fig 48 SISTORE SX CX Client as an applet il For information on operating SISTORE SX CX Clients please refer to the S
29. used The following settings are saved in the user related profile Whether to show or hide the components of the IVM Client window as well as their size and position Toolbar Navigation zone Site plans Monitor bar Alarm list Logs Message line Tree view of the favourites User defined names of the nodes Mode of the site plans section maximized or positioned freely Number of currently loaded plans Active plan For each plan Plan ID Mode of the plan whether or not it is displayed as an icon Position and size of the plan if it is positioned freely Monitor bar or monitor favourites Position of the container for software monitors 17 2 Workstation related profile 108 Siemens Building Technologies Fire Safety amp Security Products The following settings are saved in the workstation related profile Rows and columns of the grid e Position of the monitor favourites Layout e Position of the alarm monitors 03 2009 18 Trouble shooting Trouble shooting Cause of the fault Remedial action An error message is displayed when IVM Client is started as an applet The current version of the JRE is not installed on your PC Install the current version of the JRE See Section 4 3 Installing Java Runtime Environment An error message is displayed when logging on to the IVM Client Either the user name or the password is incorrect 1 Enter u
30. warning NOTICES cecceeeeeseeeeeeeeeeeeeeeeeaeeeeess 13 Meaning of the hazard symbols ccccescceecsseeeeeeeeeeeeeeeeseeeeeeeseaeeeeees 13 Software description an 14 Program WIRGOW aaa 14 Show hide sections of the program window ccccecceeeseeeeeeeeseeees 15 ROOMS AN zen ee a Erle 15 NAVIGATION zone nein a 16 PIANOVervieW Maps ona a deli 17 Device overview DOVICES cccccssececceeseecceseeeceeeecseseeessasseeesanseesseaes 18 FaVorlles warnen een anal 19 MOD sa AE E E E E E E E E ET 21 Licence and system information ccccccseeeeeeeccaeeeeeeeeeeeeeeeeseeeseeeesenaaees 21 Operational sel p u nenne 22 System requirements for the client PC cccceccsseeeeeeeeeaeeeeeeeseaeeeeeees 22 Starting the IVM CIIONt 02 cccccccesdeccesseeseceescsasseeeeececcsccessaeeeeenseces 22 ADDICT SCIMGS ee 23 Starting IVM Client as an applet uussssnnseeennneeeennennnnnnneennnnnennnnnnnnn 23 Starting IVM Client as an application 22u00ssss2nnsennneeeennnnnnnnnnnnnn 25 Installing Java Runtime EnvirOnMent ccccccsseeeceeeeeeeeeeeseeeeeeeeeesaeees 26 Logging off the IVM Server uuuueessssnnsssnnnnneennnnnnnnnnnnnnnnnnnnnnnnnnen nenne 26 Closing TENS VM Glient seen unssaineee 26 EONfIQUratlon ana een 27 Change password era 27 Classifying EDS and ODR alarms 222220000022000nnnnnneeennnnennnnnnnnn 28 Activating de
31. 15 Ged KAMERA 16 Fig 4 Navigation zone Maps tab The plan overview contains the following components e System overview The system view does not contain any sub nodes and can only be displayed or added to the favourites tree e Site plan A site plan contains the cameras configured for the site plan in the form of sub nodes e Cameras Cameras are sub nodes of the site plans in the plan overview A standard icon is used for the cameras which is configured with IVM Config The status of a camera Is visualized in the same manner as on the site plan see Section 8 1 Camera states and representation Siemens Building Technologies Fire Safety amp Security Products 03 2009 Software description 3 4 2 Device overview Devices Devices Favorites 9 xe1 Showrooam lad Video Input C 1 5howroom Gad Video Inputs C 1 5howroom 9 Cx 2 Showroom fh CX4 15 TEST B T 9 cxs 0 ley 1 ic U Kar Tea Tee Ren en ee TH Be oo Er i i qr i Fig 5 Navigation zone Devices tab The device overview contains the devices configured on the IVM Server in the form of a tree structure The device overview is based on the system overview of the server see Section 7 System overview The different conditions of the equipment are displayed as shown below Graphical representation g B State of the device Device ready for operation The device is not available no communication cros
32. Client 1 Connect the camera to the monitor see Section 8 2 Activating camera on output devices 2 Select the menu sequence Tools gt Camera control OR t Click in the toolbar gt The following dialog box opens Camera selection KAMERA 4 1 CX8 01 Man 02 ae 2 Camera PTZ control Sea 4 5 6 Camera positions Position name i SAYE hove to Fenari Delete Fig 31 Camera control 3 Make the following settings in the dialog box Camera name Monitor name Control of pan tilt camera and lens functions Switch over between mechanical and electronic control Camera focus Camera zoom middle button zoom all the way out N O JOIA G D Position name gt The camera currently activated on that monitor is controlled 54 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Cameras If another camera is activated on this monitor then the name of the new camera is displayed in the camera name box and it is then possible to control the new camera Increase camera moving speed 1 Click both mouse buttons on the corresponding control element gt The camera moving speed is doubled Controlling cameras via SISTORE MX RemoteView 8 4 2 Cameras that are connected to SISTORE MX can only be controlled via SISTORE MX RemoteView 1 Right click on any MX camera in the device overview or on the site plan
33. Define new category 3 Enter a reason for the nuisance alarm or false alarm in the text field 4 Click OK gt The new category for nuisance alarms or false alarms has been defined gt When classifying an EDS or ODR alarm you can choose from the previously defined categories see Section 16 1 2 Acknowledging and classifying EDS and ODR alarms 5 2 3 Deleting category for nuisance alarms and false alarms 1 Select the menu sequence Tools gt Options gt The Options dialog opens see Fig 12 2 Select the category for nuisance alarms and false alarm you want to delete 3 Click on Remove gt The selected category is deleted 29 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 5 3 Configuring camera groups 5 3 1 Display camera groups 1 Select the menu sequence Tools gt Groups gt The following dialog box opens Restrictchoise sall plans Fig 14 Configuring camera groups Select group 2 If only the camera groups of a particular plan are to be displayed select this plan in the Restrict choice drop down list gt All camera groups with at least one camera of the selected plan will be displayed 3 Ifall camera groups are to be displayed select all plans from the drop down list gt All camera groups that have been configured will be displayed regardless of the plans they are associated with 5 3 2 Define anew camera group Prere
34. E KAMERA_3 E KAMERA 4 ed KAMERAS E KAMERA_E E KAMERA 7 E KAMERA_B 1 0_Split Kam_s 1 OO _Split_Karmn_10 ad KAMERA 11 KAMERA_ ad KANERA_ ad KANERA_14 KAMERA 15 ad KAMERA 16 E KAMERA 17 ad KAMERA 18 Attribute Type Mame ID inputs Digitallnputs Connection Value SISTORE 2 132 4 192 168 0 84 8080 Date Time Fig 30 SISTORE Mx Display of the cameras and the alarms configured for the digital inputs 7 3 Adding the system overview to the favourites 1 Right click on das corresponding element in the plan overview gt The following context menu opens Alarm configuration MONITOR_1 MONITOR_ MONITOR_3 SISTORE 1 VCR_1 2 Select Add to favourites gt The system overview is added to the favourites see Section 3 4 3 Favorites 50 Siemens Building Technologies Fire Safety amp Security Products 03 2009 8 Cameras Cameras Each camera which has been configured for the site plan is displayed in the position where it was configured in IVM Config By assigning user rights individual cameras can be hidden so that they are visible only to users who have the appropriate rights More information can be found in the IVM Config Configuration Manual 8 1 Camera states and representation Display of the camera statuses in the site plan The shape and colour of the camera icons in the site plan can be configured in the IVM Config parameterization
35. Fire Safety amp Security Products 03 2009 Alarm list message list and logbooks 16 Alarm list message list and logbooks The alarm list the message list and the various log files are displayed in the bottom section of the IVM Client program window e Alarm list list of the current alarms e Message list list of the current system messages e Alarm log History of all the alarms that have occurred Event log History of all the IVM events that have occurred The alarm and message lists are dynamically refreshed and the alarms messages are sorted by the date in descending order current alarm message at the top Opening lists and logs 1 Select the desired tab A Alarms Messages Alarmlog Eventlog gt The selected list or the selected logbook is opened 16 1 Alarm list The alarm list see Fig 53 contains all the alarms that are still active or have not been acknowledged yet The different alarm states are displayed in different colours by default this is as follows Unacknowledged alarms Alarm active unacknowledged Alarm inactive unacknowledged Acknowledged alarms A Alarms Messages Alarmlog Event log Date arm ID omiment Type Status Priority Device Contact Fig 53 Alarm list The alarm list comprises the following columns Date Date of occurrence disappearance of the alarm Alarm ID Database ID of the alarm Comment Description of the alarm Type Type of ala
36. IDEO_SIGNAL_LO Going VIDEO_SIGNAL_LO Going MIDEO_SIGNAL_LO Going VIDEO_SIGNAL_LO Going VIDEO_SIGNAL_LO Fig 51 Ssenice Service Service System System System System System System System System System System System System Service System System System System System System System System Capserice sessionsernvice sessionsenice alarmservice pollingservice pollingservice alarnsemice alarnsemice alarmsemice alarnsemice alarmsemice alarn semice alarmservice pallingservice pollingservice Capserice alarmsenice alarmservice alarmsenice alarmservice alarnsemice alarmsemice alarmservice alarmsenice Expert search Event log 2 Select either the Event log or the Alarm log tab Siemens Building Technologies Fire Safety amp Security Products 03 2009 Search 15 2 2 Performing an expert search il e The filters are ANDed e Ihe following operators are available equals not equals lt gt less than lt less than or equal lt greater than gt and greater than or equal gt e Inthe Name Comment Priority Device Contact Event Source and Processing input fields you can search using wildcards replaces individual characters replaces partial string Example Fig 51 shows a search for an event of type Service that contains User in the description ofthe event and that occurred after 13 03 2009 and before
37. ISTORE On EX se rch un ee Aas 66 Starting SIS TORE SX CX Sedi Cienie s a 66 Starting a new SISTORE SX CX Search cccceceeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 67 Adding removing columns in the SISTORE SX CX hit list 67 Staring oS TORE MX Seal nun 68 Slaning SISTORE AX Se rch una u 70 Manual recording SISTORE SX CX MX AX ssssssnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 73 Manual start of recording sn 73 Manual stop OF recording nenne 74 IMONILOTS cu3 44 ae ren Hrn En TEEN EHRE 75 Monitor states and representation uus2424400044nnne nennen nnnnnnnennnn nenne 75 SNOW MONIOTS engen 75 FICS OFM ON Sorea a r a 76 Activating cameras groups and sequences on Monitors cceee 77 Cancelling selections 2220000000220000nnnnnnennnnnnnnnnnnnnnnnnnnnnnnnnee nennen 77 Adding monitors to the favourites cccccccccsssseceeecsaeeeeeesseeseeeeeesaaees 77 Editing the favourite S sueo naea e ae aaoi stam 78 03 2009 Siemens Building Technologies Fire Safety amp Security Products 13 13 1 13 2 13 3 13 4 13 5 13 6 13 7 13 8 13 9 13 10 13 11 13 12 14 14 1 14 2 14 3 15 15 1 15 2 15 2 1 15 2 2 15 2 3 15 2 4 16 16 1 16 1 1 16 1 2 16 1 3 16 2 16 2 1 16 2 2 16 3 16 3 1 16 3 2 16 3 3 16 3 4 16 3 5 16 4 16 4 1 16 4 2 16 4 3 17 17 1 17 2 18 19 20 Software mOnil rs c seele as 79 Show Software Monitors anal 80 Hide software mo
38. ISTORE SX CX User Manual 88 Siemens Building Technologies Fire Safety amp Security Products 03 2009 External programs 14 2 Configuring external programs 1 Select the menu sequence Tools gt Configure external program gt The following dialog box opens Name Program D icevisilvM_NT_Confil Directory DACevisilvM Client Execute options Local workstation CO WM server O Remote workstation lei Delete Apply Fig 49 Configure external programs Execute program Enter the name of the program 2 3 Select the program with the button 4 Indicate the path where the program is to be executed 5 Select one of these options Local workstation IVM Server Other workstation Use the list field to select the desired workstations 6 Confirm with Apply gt The program is added To add a new program click New To delete the program click Delete 7 Click OK gt This confirms the action The program is configured 89 Siemens Building Technologies Fire Safety amp Security Products 03 2009 External programs 14 3 Running external programs Prerequisite The external programs have been configured see Section 14 2 Configuring external programs 1 Select the menu sequence Tools gt Run external program 2 Select the program to be run from the list of previously configured programs gt The program is run 90 Siemens Building
39. QCIF 1xCIF 5xQCIF 1x4CIF 20xQCIF 1xCIF 8xQCIF 2xCIF 8xQCIF 3x3 CIF 1x4CIF 9xQCIF il Single frame 4CIF is only displayed if no more than one software monitor is configured gt The layout is now selected 82 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Software monitors 13 7 Display software monitors in full screen mode Siemens Building Technologies Fire Safety amp Security Products There are several possibilities to display the software monitors in full screen mode e Display picture on primary monitor e Display picture on secondary monitor Display picture on primary monitor 1 Right click on a blank software monitor gt The following context menu opens O Monitor 1 Monitor 2 O Fit to screen Topleft O Top O Topright O Left Center O Right BottomJeft Select layout H O Bottom select software monitor O Bottom right ges p t O Manually Show window Close lve images 2 Select Live image position 3 Click Fit to screen gt The software monitors are displayed in full screen mode on the primary monitor 4 To exit full screen mode select any other live image position See Section 13 9 Positioning software monitors gt Full screen mode is now terminated Display picture on secondary monitor Prerequisite At least two monitors are connected 1 Select the menu sequence Extras gt Select monitor
40. SIEMENS IVM CLIENT Application Software User Manual IVM V3 6 Building Technologies Fire Safety amp Security Products Lieferm glichkeiten und technische nderungen vorbehalten Data and design subject to change without notice Supply subject to availability 2009 Copyright by Siemens Building Technologies Wir behalten uns alle Rechte an diesem Dokument und an dem in ihm dargestellten Gegenstand vor Der Empf nger erkennt diese Rechte an und wird dieses Dokument nicht ohne unsere vorg ngige schriftliche Erm chtigung ganz oder teilweise Dritten zug nglich machen oder au erhalb des Zweckes verwenden zu dem es ihm bergeben worden ist We reserve all rights in this document and in the subject thereof By acceptance of the document the recipient acknowledges these rights and undertakes not to publish the document nor the subject thereof in full or in part nor to make them available to any third party without our prior express written authorization nor to use it for any purpose other than for which it was delivered to him About this Document This User Manual contains instructions for the operation of a video system using the IVM Client management software Additional information can be found in the Readme file in the directory D Cevis For information on setup and configuration please refer to the Installation Guide and to Configuration Manual Trademarks IVM is a trademark of Fire amp Security Products GmbH
41. Save selected alarms The selected alarms will be saved Save all alarms All alarms will be saved gt The Select path dialog opens see Fig 57 4 Ifthe alarms are to be saved to somewhere other than in the default directory select the desired directory 5 Click Select gt The alarms are saved 16 3 5 Generate report of nuisance alarms or false alarms 1 Right click on the alarm log gt The following context menu opens Refresh list Alarm pictures Save selected alarms Save all alarms report 2 nuisance alarm false alarm 2 Select report 3 To generate a report of all nuisance alarms select nuisance alarm 4 To generate a report of all false alarms select false alarm 104 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Alarm list message list and logbooks gt The report is generated and saved to the directory CEVIS IVM_Client Log by default 1 F AlarmLog 20080122 113310 log Editor Bearbeiten Format Ansicht DE 23 01 2008 Zx 1 Showr oom_ L 22 01 2008 Zx 1 Showr oom_ L Fig 59 Report generated from the alarm log Number of alarms Device name Camera input 16 4 Event log The event log see Fig 60 provides a list of all the events that have occurred Alarms Messages Alarm log E Qe Date rom tm id vent Gd E Date Z JEwent Type Source Processing 18 05 2005 12 08 15 Going YES_FAILURE with videomatrix
42. Technologies Fire Safety amp Security Products There are two categories of IVM Client user profiles e User related profile The user related profile saves the user specific settings irrespective of the workstation at which the user has logged in i e the user s settings will apply at all workstations See Section 17 1 User related profile e Workstation related profile The workstation related profile saves the program settings for the workstation at which the user has logged in See Section 17 2 Workstation related profile When the IVM Client is logged on to the IVM Server both the user related profile and the workstation related profile are downloaded from the server User specific changes are logged on the IVM Client When the user exits the application the IVM Client transfers this log to the IVM Server The IVM Server saves these changes in an IVM database If several users are logged on to the IVM server using the same user name then the user who logs off last will overwrite the other users profiles In case the client is disconnected from the server the current user related profile is maintained Once the connection is re established the IVM Client loads the profile from the database of the IVM Server 107 03 2009 User profiles 17 1 User related profile il When a user logs on to the IVM Server for the first time no specific profile is defined for him yet Therefore the default settings are
43. The sections that are shown or hidden are saved in the user profile see Section 17 User profiles 1 Select the View menu gt The different sections of your user interface are displayed 2 Select a section you wish to show or hide gt The section will be shown or hidden gt The sections that are displayed will use the entire user interface area You can enlarge or reduce the size of the sections that are shown The sizes of the individual sections are also saved in the user profile 3 3 Toolbar The toolbar icons allow quick access to select certain actions of the menus amp Symbol x BE 3 gt ce Go 8 Action Logging the IVM Client off the server see Section 4 4 Logging off the IVM Server Loading system overview into site plan section see Section 7 System overview Activation and definition of groups see Section 4 3 Navigation zone Activation and definition of sequences see Section 5 4 Configuring sequences Camera control see Section 8 3 Adding cameras to the favourites Positioning loaded site plans next to each other see Section 6 3 Layout of the site plans Overlap loaded site plans see Section 6 3 Layout of the site plans Calls up this user documentation see Section 3 5 Help d BE Mo Be I Siemens Building Technologies Fire Safety amp Security Products IVM system version and licence information 15 03 2009
44. activating classification of EDS and ODR alarms 28 Defining a new category for nuisance alarms and false alarms 29 Deleting category for nuisance alarms and false alarms 29 CONnIGUrING CAME a QlOUDS res ostene a R 30 Display camera QlOUDS es as a naan eens 30 Define a new camera QLOUP ccceecccccssseecceeseeeceeseecseseeessagseessanseeeseaes 30 EGIL Camera QlOUDS een 32 Activate camera Group nun 33 Delele Camera groUpsnsra rinnen 34 GONNQUNNG SEQUENCES Aue er ie lets 35 Display SEQUENCES uuus ssussennnnnnnnnnnnnnennnnnnnnnnnnnnnnnnnnn nennen nnnnnnnn nennen 35 Define a NEW sequence acini sienna eres 35 Cll SCGUEN COS ee ee 37 Display SCOUCICSS need 38 Delete SCQUCICES anne 39 5 03 2009 6 Siemens Building Technologies Fire Safety amp Security Products 6 1 6 2 6 2 1 6 2 2 6 2 3 6 2 4 6 3 6 4 6 5 Fl 7 2 7 3 8 1 8 2 8 3 8 4 8 4 1 8 4 2 9 1 9 2 9 3 9 4 9 5 9 6 9 7 10 10 1 10 1 1 10 1 2 10 1 3 10 2 10 3 11 11 1 11 2 12 12 1 12 2 12 3 12 4 12 5 12 6 12 7 Site Plans een 40 Opening Site plans sree Ei Heel 41 ICONS ondhe SIC plaasseun eohestearecsssanmosisee 41 NAY SING ONG ernennen 42 AST ICONS een a 42 Gamerallc nsssnisie teen een 42 IVIUIETUNGHON ICONS un ea 42 Layout Of the site plans ussnunuusnnennnenennnnnnennnn nennen nnnnnnnnnnennnnnnennnnnnnenn 43 Adding site plans to the favourites
45. age rate 2 Select Video Information 3 Ifall video information is to be displayed in the live image select All 4 If only individual pieces of video information are to be displayed in the live image mark the appropriate checkbox es 62 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Live images gt The video information is displayed in the live image PoE dere Er BEER STIER Ale Biene A Ei reis in Klee EBEN NER Feier 485 ee 2ER Fig 37 Video information in the live image Hide video information 1 Right click on a live image gt The context menu which opens depends on the type of camera Close Save Print Enter full screen mode Format Date Time Bit rate Image rate 2 Select Video Information 3 Ifall video information is to be removed from the live image select None 4 If only individual pieces of video information are to be removed unmark the appropriate checkbox es gt The video information is no longer displayed in the live image 63 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Live images 9 6 Displaying live image in full screen mode Entering full screen mode 1 Right click on a live image gt The context menu which opens depends on the type of camera Close Save Print Enter full screen mode gt 2 Select Enter full screen mode gt The live image is displayed in full screen mode
46. ame and or Comment input fields See the figure below Date from HA Name fe Comment fe Status il The filters are ANDed 1 To setthe filter Date click on the calendar symbols next to the from and to input fields and select the appropriate dates and times In the Name and Comment input fields you can search using wildcards il replaces individual characters replaces partial string 2 Tosetthe filter Name enter the appropriate name in the Name input field To set the filter Comment enter the appropriate comment in the Comment input field 4 To set the filter Status select the appropriate entry in the Status list box 5 Click the icon n Search gt The log search is performed using the currently set filters Reset filters You can reset all search filters for instance to start a new search 1 Clickthe icon Reset filter gt The filters are reset 103 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Alarm list message list and logbooks 16 3 4 Save alarms il The alarms are saved to the directory CEVIS IVM_Client Log by default 1 Select the alarm s you would like to save 2 Right click on an alarm that you have selected gt The following context menu opens Liste aktualisieren Alarmbilder Ausuew hlte Alari r AWS GeWanite eit Alle Alarme Sichern Report 3 Select one of the following actions from the context menu
47. and 288 vertical pixels and a frame rate of 30 images per second 4CIF Quad Common Intermediate Format Image format with a resolution of 704 horizontal pixels and 576 vertical pixels and a frame rate of 30 images per second ANSI American National Standards Institute API Application Programming Interface BMP Windows Bitmap Windows graphics format for storage of images with up to 16 7M colours CCTV Closed Circuit Television CIF Common Intermediate Format Image format with a resolution of 352 horizontal pixels and 288 vertical pixels and a frame rate of 30 images per second Codec Compressor decompressor Algorithms for compressing decompressing video data DLL Dynamic Link Library Program library used by Microsoft Windows Frame Grabber Real time video digitizer converts analog video signals into digital signals The digital video signals can be processed using a PC GIF Graphics Interchange Format Graphics format for compression of image files with a colour depth of 256 colours 8 bits per pixel IVM Interactive Video Management System Siemens software package for controlling CCTV systems under Microsoft Windows LAN Local Area Network Local computer network frequently used within companies LPT Line Print Generally used designation for the parallel port of a PC MCI Media Control Interface ODBC Open Database Connectivity
48. ation IVM tag Archive comment entered in the IVM Config Edit alarm properties Organization More detailed information on the operation of the SISTORE SX CX Client and SISTORE SX CX Search can be found in the SISTORE SX CX Client User Manual 10 2 Starting SISTORE MX search il SISTORE AX MX do not support camera groups Prerequisite The camera is connected to a SISTORE MX A SISTORE MX Server is available SISTORE MX RemoteView is installed on the IVM client PC The SISTORE MX password is identical with the password for the IVM Client The password of the SISTORE device must be identical with the password used in the IVM Client for logging into the SISTORE device 1 Open the site plan see Section 6 1 Opening site plans 2 Click the desired camera icon with the right mouse button 3 Select Open archive gt The following submenu opens Openarchive gt 30 minutes Start record 46 hours Open camera 2 month 3 days 2 weeks Close all Camera 4 Select the desired time period Example If you select 3 days the integrated SISTORE MX RemoteView will be started and a search be launched for the corresponding camera over the last three days gt The following window opens 68 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Search Zaj SISTORE RemoteView 1 Playback File view Database Write protection E22 BEE 28 Gi elo SIEMENS m
49. avourites d E B u E MONITOR 1 MONITOR _ MONITOR 3 MONITOR _4 Video Output 1 Output panel Favorites Fig 43 Monitors Output panel Display monitors in the output panel The Output panel tab lists all output devices released for the logged in user monitors SISTORE SX inputs Telscan WEB server inputs sorted according to their ID 75 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Monitors 1 Right click on the Output panel or Favorites tab gt The following context menu opens U Faworites O Software monitors on left side O Software monitors on right side 2 Mark the checkbox Output panel gt The monitors are displayed in one row in the Output panel tab Display monitors as favourites Use the Favorites tab to position the monitors selected from the monitor bar freely within a grid 1 Right click on the Favorites or Output panel tab gt The following context menu opens O Output panel lw Favorites O Software monitors on left side O Software monitors on right side 2 Mark the Favorites checkbox gt The monitors are displayed within a grid in the Favorites tab 12 3 Hide monitors 1 Right click either on the Output panel tab or on the Favorites tab gt The following context menu opens Output panel Favorites U Software monitors on left side O Software monitors on right side 2 Unmark the checkboxes gt The monitors will no longer be dis
50. bmenu opens Acknowledge alarm Acknowledge selected alarms Acknowledge all alarms MVMM CX3 02 EDS Kam0 3 Select the desired camera gt The SISTORE SX CX search window is opened see Section10 1 SISTORE SX CX search VM Cx8 02 EDS a o gt Ye From 06 03 2008 13 58 58 To All cameras Tag Rules Comment Standard Regel fv und i EDS kam IBsO3 2008 par G fideo Input 7 YM C HS5 02 ED5 een Fig 55 SISTORE SX CX search Search More detailed information on the operation of the SISTORE SX CX Client and SISTORE SX CX Search can be found in the SISTORE SX CX Client User Manual 98 Siemens Building Technologies Fire Safety amp Security Products 03 2009 16 2 Message list Alarm list message list and logbooks Alarms Messages The message list contains current messages of the following categories e System messages occurring once with the state Unique e g Server Mode e Messages occurring at the device end with the state On error or OK e g the communication connection has failed e Messages occurring at the client and the server end with the state Unique e g failure to connect camera Colour representation of messages Messages Message is displayed unacknowledged Message acknowledged Alarm log Event log Siemens Building Technologies Fire Safety amp Security Products Fig 56 Message list Columns of the message list
51. ded site plans Arrange site plans next to each other 1 Click on Window in the menu bar 2 Select Arrange windows 43 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Site plans gt The opened site plan windows are tiled next to each other Depending on the available space they are automatically arranged in columns rows Fig 23 Site plans system overview section Site plans tiled next to each other 6 4 Adding site plans to the favourites 1 Right click on das corresponding element in the plan overview gt The following context menu opens Alarm configuration MONITOR_1 MONITOR_ MONITOR_3 SISTORE 1 VCR_1 2 Select Add to favourites gt The site plan is added to the favourites see Section 3 4 3 Favorites il The same sub node of a site plan can be added to the favourites tree several times 44 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Site plans 6 5 Closing site plans Closing a site plan 1 Click on the site plan you wish to close in the Site plans System overview section 2 Click on Ed gt The site plan is closed Closing all site plans 1 Select the menu sequence Window gt Close all windows gt All the site plans that are opened in the Site plans System overview section will be closed 45 Siemens Building Technologies Fire Safety amp Security Products 03 2009 System overview 7 System overview
52. ean I ren Search mask mi ca x Sensitivity normal high Stepwidth normal C fine AXIS 206M 19 07 06 09 36 25 l l Search Summary zj 71972006 8 41 58 AM 7192006 12 14 58 PM 7 19 2006 3 47 58 PM j 771972006 Overview a es CCIS1337 LP 01 JVC VN CB55U Kamerali Kameral2 Kameral3 Kamera04 Kamera05 Update 24 ela 1 13 Fig 39 SISTORE MX Search Player control ALTER It is recommended to set the language selection to Automatic i The language is selected in the configuration mode of SISTORE MX RemoteView Further information on this can be found in the SISTORE MX Configuration Manual 5 Right click on the image gt The following context menu opens 69 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Search il b Flay d Play backwards E Stop ip Next image 4 Previous image Image quality d Store position Jump to position Set start position Set end position Print scene SCENE th Vay Li gu th I Pa DI Br a 1 Show Frame information Fig 40 SISTORE MX Search Context menu of the live image zoom interpolation More detailed information on the operation of the SISTORE MX RemoteView and SISTORE MX Search can be found in the SISTORE MX User Manual 10 3 Starting SISTORE AX search il il 70 Siemens Building Technol
53. ecurity Products 03 2009 Search 15 2 Expert search 15 2 1 The expert search tool provides generic filters with which it is possible to search for alarms and events Various operators are available for this purpose Starting expert search Alarms Messages 1 Select the menu sequence Tools gt Expert search gt The following dialog box opens Alarm log Event log O wE DE G F DE JE 0 i fuser Date A Event Type Source Processing 13032009 16 12 18 1 amp 032009 15 44 12 13032009 15 44 12 1503 2009 15 31 1503172009 15 31 1503 2009 15 31 1503 2009 15 31 1303 2009 15 31 1303 2009 15 31 1503 2009 15 31 1303 2009 15 31 1503 2009 15 31 1503172009 15 31 46 45 45 45 45 45 45 45 45 45 13032009 15 29 41 10312009 15 23 41 15 03 2009 15 29 32 13032009 15 29 23 10312009 15 29 23 13032009 15 29 23 10312009 15 23 23 103172009 15 29 23 13032009 15 29 23 10312009 15 23 23 1032009 15 29 23 92 ser admin logged in ser admin logged out Session service stopped Going VIDEO_SIGNAL_LO GoingVKS_FAILURE with Going YKS_FAILURE with Going VIDEO_ SIGNAL LO Going VIDEO _ SIGNAL AAT Going YIDEO_ SIGNAL_ LA Going VIDEO_SIGNAL_LO GoingVIDEO_SIGNAL_LO Going VIDEO_SIGNAL_LO Going VIDEO_SIGNAL_LO Coming VKS_FAILURE wit Coming YKS FAILURE wit ser admin logged in Going VIDEQ_SIGNAL_LO Going VIDEO_SIGNAL_LO Going MIDEO_SIGNAL_LO Going V
54. ee Section 3 3 Toolbar Navigation zone The navigation zone contains different system views and offers the opportunity to open site plans and to perform camera specific functionalities see Section 3 4 Navigation zone Site plans System The Site plans System overview section depicts the available site plans or the system overview The plans overview can be arranged in various layouts or maximized in size See Section 6 Site plans 5 Monitor bar The monitor bar displays the available outputs monitors TELSCAN WEB Server etc These can be used to activate the cameras in the site plan currently loaded Monitor favourites can be used instead of the monitor bar to arrange monitors in user customized layouts see Section 12 Monitors 6 Alarms Messages The Alarms Messages Logs section displays the list of current alarms or messages the alarm log or the event Logs log depending on the tab selected see Section 16 Alarm list message list and logbooks 7 Status bar The status bar contains information on failed user actions e g failed camera activation and spontaneous messages from the IVM Server 14 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Software description 3 2 Show hide sections of the program window You can show or hide the following sections Toolbar Navigation zone Site plans System overview Monitor bar Alarms Messages Logs Status bar il
55. en site plans via the plan overview Prerequisite You have created at least one plan with IVM Config More information can be found in the IVM Config Configuration Manual Display site plans via the menu 1 Select the menu sequence File gt Load plan gt The available site plans are depicted in the context menu 2 Click on the desired plan gt The selected plan will be displayed in the site plan area see Fig 20 Display site plans via the plan overview 1 Click on the desired site plan in the Maps tab gt The site plan is displayed in the Site plan system overview section see Fig 2 Site plans with an active DVP alarm are identified with a red background 6 2 icons on the site plan Siemens Building Technologies Fire Safety amp Security Products Various icons are displayed on the site plan Fig 21 Site plan Icons Layer icon Alarm icon Camera icon A oO DD Multifunctional icon 41 03 2009 Site plans 6 2 1 Layer icons Using the layer icons you can jump to another plan e g from the site plan to the floor plan etc Whether the layer icons are shown or hidden can be configured via the IVM Config software More information can be found in the IVM Config Configuration Manual 6 2 2 Alarm icons The alarm states are indicated by the following icons Le Alarm active LA Alarm inactive LA Alarm disabled 6 2 3 Camera icons T
56. ens Add to favorites Connect to monitor MONITOR MONITOR MONITOR_3 MONITOR_4 Video Output 1 Video Output 2 The context menu contains a list of outputs for which the operator is authorized gt By selecting one of the output devices the camera is activated on that device gt The colour of the camera icon changes as soon as the camera is activated see Section 8 1 Camera states and representation Activate camera by drag amp drop 1 Select the camera to be activated on a monitor TELSCAN WEB Server or SISTORE 2 Use drag amp drop to drag the camera on the monitor in the monitor bar gt Following activation the name of the activated camera is displayed in the monitor icon Activate camera by quick selection Prerequisite A monitor has been selected 1 Double click on a camera icon in the device overview gt The camera is activated on the selected monitor by quick selection 03 2009 Cameras 8 3 Adding cameras to the favourites 1 Right click on das corresponding element in the plan overview gt The following context menu opens Alarm configuration MONITOR_1 MONITOR_ MONITOR_3 SISTORE 1 VCR_1 2 Select Add to favourites gt The system overview is added to the favourites see Section 3 4 3 Favorites 53 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Cameras 8 4 Camera control 8 4 1 Controlling cameras via IVM
57. ens Output panel Favorites O Software monitors on right side 2 Ifthe software monitors are to be displayed on the left side activate the checkbox Software monitors on left side lf the software monitors are to be displayed on the right side activate the checkbox Software monitors on right side gt The software monitors are now displayed either on the left or on the right side 80 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Software monitors 13 2 Hide software monitors Prerequisite The software monitors are displayed server still trigger the display of the corresponding live image at the configured positions regardless il Although the software monitors can be hidden any activations on alarm monitors reported by the whether the software monitors are hidden or not 1 Click on the Favourites or Output panel tab with the right mouse button gt The following context menu opens Output panel Favorites O Software monitors on right side 2 Unmark the checkbox Software monitors on left side or Software monitors on right side gt The software monitors are now hidden 13 3 Display live image of camera Prerequisite The camera is Web compatible i e it is connected to a SX CX MX AX or TELSCAN WEB Server 1 Use drag amp drop to drag the selected camera to the desired software monitor gt The software monitor in the container is displayed in dark g
58. esiCOM1 Busld SIMATRIXZEAMERA_T Failed to retrieve camera 2 SIMATRIA_AKAMERA_2 Failed to retrieve camera SIMATRIA_2KAMERA_3 Failed to retrieve camera SIMATRIF_2 Communication connect Fig 26 Video matrix Display of the connected cameras 48 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Siemens Building Technologies Fire Safety amp Security Products System overview Attribute value IO_SERWER IC Server_4 4 Connection 0 0 0 0 0 EAL arrris 5 DateTime Components Message Fig 27 lO Server Display of the alarms that are configured for the digital inputs KAMERA 1 Type o TELEMAT sk KAMERA_ Mat Telemat KAMERA 3 GX KAMERA_4 EA KAMERAS ReOutputs E EI kaMeERA 6 Digitallnputs GX KAMERA_T MA KAMERA 8 Fig 28 TELEMAT MTD Display of the connected cameras GN KAMERA SISTORE_CK EN KANERA_2 CX 04080004 GX KAMERA_3 wi KAMERA 4 4 Connection 141 73 39 45 1 2050 Outputs 0 Digital In 0 DateTime Component Fig 29 SISTORE CX Display of the cameras and the alarms configured for the digital inputs 49 03 2009 System overview E KAMERA_ E KAMERA_
59. f monitors alarm lists and alarm logs Ensures system security using passwords and user profiles Live image on screen display OSD by integration of the TELSCAN WEB Server Connection of groups Sequences and group sequences Graphical visualization of events such as video signal failure camera connection etc Integration of the SISTORE SX CX client for search and playback of video recordings from SISTORE SX CX servers integrated in the system and for display of live images PTZ Camera controlling There are two possible ways to run the IVM Client Asa Web solution Applet The IVM Client is installed together with the IVM Server on a dedicated server and can be started and operated from any Windows client This requires a TCP IP connection between the client and the web server or IVM server as well as the correct versions of Microsoft Internet Explorer and the Java Runtime Environment As an application The IVM Client can be installed on client computers together with the Java Runtime Environment and be run as a conventional Windows application From the operating stations any camera regardless of the associated station can be selected Various terminals can be assigned to each operator Each of these operators can also take over the work of other operator terminals if necessary Two terminals can simultaneously monitor the same line The system administrator can assign the user privileges a
60. for automatic position cycle When this button is activated the camera will move to the stored positions automatically in a predefined order Further information on this can be found in the SISTORE MX Configuration Manual 03 2009 Live images 9 Live images Live images from the selected camera can be displayed from the IVM client e The IVM Client in Internet Explorer does not support SISTORE MX AX live images The live images of IP cameras that are connected to a TELSCAN WEB Server are displayed ina new browser window If the live image from an IP camera is displayed on the IVM Client then only il the size of the live image can be changed e The context menu of the live images in systems with SISTORE MX device differs from the context menus of other SISTORE devices see Fig 40 The live image of PTZ cameras can be controlled via the context menu of the corresponding live image il The menu items of the context menus of the different cameras differ depending on the camera type Number of live images with different SISTORE devices Devices Number of live images Number of live images in application in Internet Explorer SISTORE SX CX Depends on quality CIF 25 ips 6 4 2CIF 25 ips 4 2 4CIF 25 ips 2 1 SISTORE AX 1 no live images SISTORE MX 4 no live images 57 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Live images 9 1 Displaying live images
61. he SISTORE AX User Manual 72 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Manual recording SISTORE SX CX MX AX 11 Manual recording SISTORE SX CX MX AX 11 1 Manual start of recording The menu items shown below are available only for devices providing integrated recording functionality There are several possibilities to manually start a recording e Manual start of recording via the device overview e Manual start of recording via the site plan Prerequisite The digital video recorder that is connected to the selected camera is equipped with a hard disk drive Manual start of recording via the device overview 1 Right click on a camera icon in the device overview gt The following context menu opens Add to favorites Open archive Open camera Close all camera 2 Select Start record from the context menu gt The camera symbol is displayed with a red dot gt Recording has been started Manual start of recording via the site plan 1 Right click on a camera icon on the site plan gt The following context menu opens Open archive Open camera Close all Camera 2 Click on Start record gt The camera icon is displayed with a blue background gt Recording has been started 13 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Manual recording SISTORE SX CX MX AX 11 2 Manual stop of recording Prerequisite Rec
62. he camera icons can visualize the following states e Camera ready for operation e Camera connected e Camera failure e Alarm has been triggered e SISTORE recording active on camera See Section 8 1 Camera states and representation 6 2 4 Multifunction icons IVM commands like moving cameras to stored positions connecting cameras etc can be executed directly using the multifunctional icons The multifunction icons can be configured in IVM Config with a list of commands Execute individual commands 1 Right click the multifunction icon gt The context menu will open 2 Select the command you wish to execute gt The selected command will be executed Execute all commands 1 Double click on the desired multifunction icon gt All the commands associated with the multifunction icon will be executed 42 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Site plans 6 3 Layout of the site plans There are two possible ways to arrange site plans e Cascade site plans e Arrange site plans next to each other Cascade site plans 1 Click on Window in the menu bar 2 Select Cascade windows gt The opened site plan windows are cascaded in an overlapping manner NE EEE EEE l ey T d ehe u J K Cs eo ee LE O 3 i une enmet 4 Vay 2 ate a vm alt r T lt i L tn a ir Plani Fig 22 Site plans system overview section Casca
63. ht mouse button gt The following context menu opens Move tem up Move tem down Remove item Open archive Start record Open camera Close all camera 2 Select Rename item 3 Enter the name of the folder in the text field 4 Click OK gt The name of the node has been changed Removing nodes 1 Click on a sub node with the right mouse button gt The following context menu opens Move tem up Move tem down Rename tem Open archive Stan record Open camera Close all camera 2 Select Remove item gt The node has been removed from the Favorites tab 03 2009 3 5 Help Software description 3 6 In Windows XP SP2 access to the web client help is blocked by a popup blocker Please contact your administrator to deactivate the blocker Prerequisite Select the menu sequence Help gt PDF Help gt The IVM Client Online Help is provided in the form of a PDF file The Acrobat bookmarks can be used to find the information you need Licence and system information Adobe Acrobat Reader must be installed on your computer It is included on the accompanying CD Siemens Building Technologies Fire Safety amp Security Products Fig 7 Select the menu sequence Help gt About IVM Client IM 3 4 C General informations System informations No Clients No YKS Mo SISTORE No OTN No isiovvaye Mo Telernat No TELSCAN Version server Version client Version config
64. il The password of the SISTORE device must be identical with the password used in the IVM Client for logging into the SISTORE device 1 Open the site plan see Section 6 1 Opening site plans or Section 3 4 Navigation zone gt The following window opens 58 Siemens Building Technologies Fire Safety amp Security Products Fig 33 Site plan 2 Click the desired camera icon with the right mouse button gt The context menu which opens depends on the type of camera Open archive Start record Close all camera 3 Select the menu item Open camera 03 2009 Live images gt The live image of the selected camera will be displayed Jend rap Tasi tobac Canhouranan Window Hap _ Fig 34 Live image display 59 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Live images 9 2 Saving live images 1 Right click on a live image gt The context menu which opens depends on the type of camera Enter full screen mode 2 Select Save Print gt The following dialog box opens Picture Settings IW Ality eta Od Le pos det otek ta dee at oo a ft at Pa sf gt TEE Ea it EY Peg fo hl edt a ED ey ad eT pO a a pt e 0 0 0 1 0 2 0 3 0 4 1 5 0 6 Uf 0 5 0 9 1 0 Filesize 1 bytes Reset Page Setup Print Print Save AS O saveas Cancel Cancel Fig 35 JPEG Editor Save print live image 3 Click on Save as
65. images of the camera group are displayed on the selected monitor und the subsequent monitors 33 03 2009 Configuration Relative activation of camera groups by drag amp drop Camera groups can be activated relatively via the context menu The video images of the selected camera group are then displayed on the selected monitor software monitor and the subsequent monitors software monitors 1 Select the menu sequence Tools gt Groups gt The Select group dialog opens see Fig 14 2 Use drag amp drop to drag the selected group to the desired monitor gt The video images of the camera group are displayed on the selected monitor software monitor und the subsequent monitors 5 3 5 Delete camera groups Prerequisite The operator has the right Configure groups More information can be found in the IVM Config Configuration Manual 1 Select the menu sequence Tools gt Groups gt The Select group dialog opens see Fig 14 2 Select the camera group you would like to delete 3 Click on Delete gt The selected camera group is now deleted 34 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 5 4 Configuring sequences 5 4 1 Display sequences 1 Select the menu sequence Tools gt Sequences gt The following dialog box opens Restrictchoise sall plans JID Name Comment 1 sequence 1 2 sequence 2 Edit Delete Close Fig 17
66. ion by technical specialists is recommended 2 2 Work safety information e Read the general safety precautions before operating the software Keep this document for reference e Always pass this document on together with the product e Please also read the safety precautions for the devices that are operated by the software e Any national or local safety standards or laws that apply to the development design installation operation or disposal of a product must be adhered to in addition to the instructions in the product documentation 2 2 1 Handling Damage due to improper handling e Protect the CD from scratching e To clean the CD use a soft dry cloth 2 2 2 Transport Damage during transport e Always transport the CD in the case it originally came in 2 2 3 Operational setup Dangerous situation due to false alarm Make sure to notify all relevant parties and authorities providing assistance before testing the system e To avoid panic always inform all those present before testing any alarm devices 12 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Safety 2 2 4 Data loss after update Data loss after update Make sure to backup all data before updating the software on the device 2 2 5 Storage Damage due to improper storage Always store the CD in its protective case Keep the CD in an environment with a relative humidity of 10 90
67. ites main folder as subordinate nodes Just like in the device overview you can use drag amp drop to load the nodes to the monitors of the monitor bar The context menu comprises the menu entries for favourites as well as the specific menu items for plans cameras or monitors Adding a folder 1 Click on the Favourites folder with the right mouse button gt The context menu opens Move tem up Move tem down Rename item Add folder 2 Select Add folder gt The following dialog box opens Rename iter 4 i LIE Cancel 3 Enter the name of the folder 4 Confirm with OK gt A new subfolder has been added to the Favorites main folder il New orders can be created in any other created folder as well subfolder in subfolder Siemens Building Technologies Fire Safety amp Security Products 19 03 2009 Software description 20 Siemens Building Technologies Fire Safety amp Security Products gt You can use drag amp drop to move the subordinate nodes to your newly created folders Moving nodes 1 Click on a sub node with the right mouse button gt The following context menu opens Move tem up Move tem down Rename item Remove item Connect to monitor 2 To move a selected node up choose Move item up 3 To move a selected node down choose Move item down gt The node is moved up or down Renaming nodes 1 Click on a sub node with the rig
68. lient via Internet Explorer or as an application which is based on TCP IP The access privileges to server functions are controlled and restricted via the user profile O SIMATRIX _ TELEMAT Co D CAMERA SISTORE NT Controllin Data base SISTORE SX 2 IVM a SISTORE CX RS232 SERVER MS DE SISTORE MX RS485 eo C SISTORE AX J TCP IP C Communication via IVM API Direct ODBC Open DataBase Connectivitiy communication Ma IVM Client Operating Visualisation o Password levels E74 IVM Web Web based Operating Visualisation Ne N 2 Fig 1 Siemens Building Technologies Fire Safety amp Security Products a IVM Config Configuration Operator stations Interfaces Alarm management i g d Component overview wy De zo SN IVM Terminal o External e applications Camera selection Access with SUT 48 WinCC CKAxx GMA A i P 11 03 2009 Safety 2 Safety 2 1 Target readers The instructions in this document are designed for the following target readers Target readers Qualification Activity Condition of the product Understands the Performs only the The product is installed instructions in the procedures for proper and configured documentation and is operation of the product able to apply them in practice Has working knowledge of computers Additional instruct
69. mode The icons described below are the default symbols Graphical representation CH mi bei State Camera ready for operation Camera connected camera with green background Camera failure camera crossed out Alarm has been triggered camera with red background SISTORE recording active on camera camera with blue background Display of the camera statuses in the device overview Graphical representation u 2d Siemens Building Technologies Fire Safety amp Security Products State Camera ready for operation Camera connected green camera icon Camera failure camera crossed out Alarm has been triggered red camera icon Camera is recording red dot on camera icon Camera unknown question mark on blue background No camera status information available This is often due to configuration errors 51 03 2009 Cameras 8 2 Activating camera on output devices 52 Siemens Building Technologies Fire Safety amp Security Products Prerequisite Camera is connected to a video matrix or comparable e g Cellstack Visio Wave A camera can be activated on a monitor in three different ways e via context menu e by drag amp drop e by quick selection Activating camera via context menu 1 In the plan overview select the camera to be activated on a monitor TELSCAN WEB Server or SISTORE 2 Right click on the desired camera icon gt The following context menu op
70. n Live image archive search x x y The number of live images depends on the Internet Explorer performance of the computer see Tab 2 Evaluation of alarm inputs Z S S I O Evaluation of video events x x of e g MD Utilization after SIMATRIX x x y Utilization before SIMATRIX Y y Y Automatic and manual start of y lt S MX max 6 recording commands per Alarm of recording G 10 Siemens Building Technologies Fire Safety amp Security Products Number of live images SISTORE AX 1 SISTORE MX 4 SISTORE SX CX 6 x CIF 25 ips OR 4 x 2CIF 25 ips O 2 x ACIF 25 ips Tab 1 Number of live images using SCENIC W600 2 4 GHz 4 x CIF 25 ips OR 2 live images 2CIF 25 ips OR 1 live image 4CIF 25 ips Number of live images Tab 2 Number of live images standard quality We recommend using only one SISTORE type in CCTV systems It is however possible to combine SISTORE SX and SISTORE CX 03 2009 Description of functions 1 3 Operating principle The IVM Client is executed either as a Java applet within the Java Runtime Environment JRE integrated in the Internet Explorer or as an application within the JRE The IVM Client communicates with the IVM Server via HTTP using the Web server software IVM Client via Internet Explorer installed on the IVM server loading the applet and the required resources using the IVM API interface IVM C
71. nce There are several possibilities to display a sequence on a monitor or on a software monitor e Absolute activation OR e Relative activation via context menu OR e Relative activation by drag amp drop Prerequisites The operator has the right Configure sequences More information can be found in the IVM Config Configuration Manual The IVM Server workstation is already assigned monitors More information can be found in the IVM Config Configuration Manual At least one software monitor is already configured At least one sequence Is defined Absolute activation of sequences Sequences can be activated absolutely The video images of the sequence are then displayed successively on a previously defined monitor software monitor 1 Select the menu sequence Tools gt Sequences gt The Select sequence dialog opens see Fig 17 2 Select the sequence you want to activate on the monitor previously defined in the sequence 3 Click on Connect gt The video images of the cameras defined in the sequence are displayed successively on the previously defined monitor software monitor for the period of time defined in the Interval column Relative activation of sequences via context menu Sequences can be activated relatively via the context menu The video images of the sequence are then displayed successively on a previously selected monitor software monitor 1 Select the menu sequence Tools gt Seque
72. nces gt The Select sequence dialog opens see Fig 17 2 Right click on the sequence you wish to display gt The context menu of the sequence opens MONITOR_2 X MONITOR 03 2009 Configuration 3 From the context menu select the monitor on which the video images are to be displayed successively gt The video images of the cameras defined in the sequence are displayed successively on the selected monitor software monitor for the period of time defined in the Interval column Relative activation of sequences by drag amp drop Sequences can be activated relatively using the drag amp drop function The video images of the sequence are then displayed successively on a previously selected monitor software monitor 1 Select the menu sequence Tools gt Sequences gt The Select sequence dialog opens see Fig 17 2 Select the sequence you wish to display 3 Use drag amp drop to drag the selected sequence on the desired monitor in the monitor bar gt The video images of the cameras defined in the sequence are displayed successively on the selected monitor software monitor for the period of time defined in the Interval column 5 4 5 Delete sequences Prerequisite The operator has the right Configure sequences More information can be found in the IVM Config Configuration Manual 1 Select the menu sequence Tools gt Sequences gt The Select sequence dialog opens see Fig 17 2
73. nd functions by means of the user profile This strategy makes it possible to define the operating workstations according to administrative areas such as a factory site building A building B Corridor 1 etc or according to multifunctional criteria Each graphical operator interface can be configured in several different ways from the user profile This makes it easy to take operation over from another location The images are output on video monitors The status alarm and video signal failure of the cameras is visualized on the site plan by means of different icons 03 2009 Description of functions il The images and icons must be in an image format GIF JPG If there are TELSCAN WEB Servers or SISTORE SX CX Servers integrated in the system then it is possible to display the video images directly on the VGA monitors of the graphical operator interface using the TELSCAN WEB applet or the SISTORE SX CX Client Using the images and associated information it is possible to rapidly implement measures appropriate to the situation The user can monitor the video system view the terminal plans and specifically select and control the individual video components 1 2 Functions IVM SISTORE In conjunction with SISTORE devices the IVM Client offers the following functions SISTORE AX SISTORE MX SISTORE CX Comment Live image archive search vv y S Limited number of live images see Tab 1 applicatio
74. nitors ernennen 81 Display live image of camera uussnunsennennneennnnnnnnnennnn nennen nnennnn nennen 81 DUPIICATE IVEINAgE sense 81 Interchange live images on monitors uuueensenneennennnonennnnennnnnnnnnennne nenne 82 Select IAYOU een einen 82 Display software monitors in full screen Mode uu44444ssenne nennen 83 Assigning software Monitors uueasenneennennnnennnnnnnnnennnnnnnnnennnnnnnnennne nennen 84 POSITIONING software MONItOTS uuueanennneennnnnennennnn nennen nennen nnnennnn nennen 85 Glosing liveimagesasane eu 85 Manually closing live alarm images ccccsesccccseeeeeeeeeeeeeeeseeeeaeeeeeaaaees 86 Restoring live alarm images 22u022204200020nnnennnnnnn neuen nennen nennen nennen 86 External Pr0oGrams 0 2 een 87 starting SISTORE SACK Client 87 Configuring external PrOQraMs cccccssssseeccssseeceeeceesseeeeecseeseeeesaaneeeess 89 Running external ProQrams cccccsesccccsseeeeeeeeeeeeseeeeeeceaeeeessaeeeesenseeesaaes 90 SANGIN naar ea 91 LOG SCAN GM een en een 91 EX DCM SEA ch ernennt 92 otaning expen searchziiusnsensin een 92 Performing an expert search 222002200000020nnnennnnnn nennen nennen nennen 93 SONJ Search resullsa aan hs Leet Maayan wee ee 94 FOr LO SON eating 94 Alarm list message list and logbooks uuuuurmunnnaaauunnnnnnnnnnnnnnnnnnnnnnnn 95 PANIIT NIG a een se 95 Acknowledge Aldimssanaseaeume aaa 96 Acknowledging and clas
75. nologies Fire Safety amp Security Products The first start of the integrated SISTORE SX CX Client takes longer than the subsequent starts as the connection has to be established and the client initialized Prerequisites A ISTORE SX CX Server is available A SISTORE SX CX client including the JAVA Runtime Environment is installed on the IVM client PC The JAVA Runtime environment is installed together with the SISTORE SX CX Client The camera is connected to a SISTORE SX CX The password of the SISTORE device must be identical with the password used in the IVM Client for logging into the SISTORE device If the passwords are not identical live image display will not be possible 1 Open the site plan see Section 6 1 Opening site plans 2 Click the desired camera icon with the right mouse button 3 Select Open archive gt The following submenu opens Openarchve Video Input 6 CX8 06 TEST 30 minutes 48 hours 2 month 3 days 2 Weeks Start record Open camera Close all Camera The submenu may vary depending on the configuration settings If the camera is not assigned to a camera group no camera or camera group can be selected 4 Select a camera or a camera group Example If you select the camera group Gate 2 and the time interval 2 weeks a search will be launched for all the cameras belonging to the camera group Gate 2 over the past two weeks 5 Select the desired time period
76. nsitive 3 Enter admin in the User field 4 Enter admin in the Password field 5 Click OK gt IVM Client is now started as an application il We advice to change the password after initial start up see Section 5 1 Change password 25 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Operational setup 4 3 Installing Java Runtime Environment Prerequisites You have admin user rights The web site http Server ivm ivmweb is opened see Section 4 2 2 Starting IVM Client as an applet 1 Click on GET IT FREE gt The web site http java com de download index jsp will be opened 2 Click on Download now 3 Follow the instructions on the web site More information on the installation can be found on the website at http java com de download windows _ie jsp gt The current version of the JRE is now installed gt IVM Client is now started as an applet 4 4 Logging off the IVM Server il Before switching to another website always log off the IVM Client application or close the Internet Explorer 1 Select the menu sequence File gt Logoff gt You are now logged off gt The IVM Client remains open You can log on to the server once more Before the client logs off the IVM Server the changed user profile settings see Section 16 are transferred to the server 4 5 Closing the VM Client Before the client logs off the IVM Ser
77. o streams in case of an alarm Alarm software monitors are shown in pink when disabled and in red when the alarm is enabled The displayed number indicates the order of the alarm monitors Software monitors to activate These software monitors are used to activate live images of the desired camera per drag amp drop on the position defined by the container Except for the layout they actually offer the same functionality as the Open camera menu item of the camera These monitors are shown in light green if a camera is not activated and in dark green as long as a camera Is activated 19 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Software monitors The IVM Client offers the option of configuring the layout of the software monitors on the screen as well as a control element monitor bar or favourites showing the state of the software monitors and used to activate cameras on software monitors 13 1 Show software monitors The software monitors can be displayed either on the left side or on the right side in the Output panel and Favorites tabs J Ed E MONITOR 1 MONITOR 2 MONITOR 3 SISTORE 1 Output panel Fig 45 Software monitors displayed on the left side Prerequisite The software monitors are configured More information can be found in the IVM Config Configuration Manual 1 Click on the Favourites or Output panel tab with the right mouse button gt The following context menu op
78. of the group OR Use drag amp drop to add the required cameras and monitors to the corresponding table cells from the site plan 7 Click OK gt The new camera groups is now defined gt The camera group is added to the already defined groups 31 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 5 3 3 Edit camera groups Prerequisite The operator has the right Configure groups More information can be found in the IVM Config Configuration Manual 1 Select the menu sequence Tools gt Groups gt The Select group dialog opens see Fig 14 2 Select the camera group you would like to edit 3 Click Edit gt The following dialog box opens video Input 1 CX8 06 TEST MONITOR_1 Video Input 6 CXS 06 TEST MONITOR 2 W Group for switching k Group for recherche Fig 16 Configuring camera groups Modify group 4 Make the desired changes see Section 5 3 2 Define a new camera group 5 Click OK gt Your settings are saved The camera group has been edited 32 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 5 3 4 Activate camera groups Siemens Building Technologies Fire Safety amp Security Products There are several possibilities to activate acamera group on a monitororona software monitor e Absolute activation OR Relative activation via context menu OR e Relative activation
79. ogies Fire Safety amp Security Products SISTORE AX MX do not support camera groups Prerequisites Camera is connected to a SISTORE AX A SISTORE AX is available The SISTORE AX RAS software is installed on the IVM client PC The colour depth of the graphics card is set to 32 bits The password of the SISTORE device must be identical with the password used in the IVM Client for logging into the SISTORE device 1 Open the site plan see Section 6 1 Opening site plans 2 Click the desired camera icon with the right mouse button 3 Select Open archive gt The following submenu opens 03 2009 SISTORE AX Watch EB Siemens Building Technologies Fire Safety amp Security Products Start record Open camera Close all Camera 30 minutes 48 hours 2 month 3 days 2 Weeks 4 Select the desired time period gt The following window opens DateTime 2006 07 19 16 01 36 2006 07 19 16 01 36 2006 07 13 16 01 36 2006 07 19 16 01 36 2006 07 19 16 01 36 2006 07 19 16 ot 36 2006 07 19 16 01 35 SISTORE AX Watch Alarm Out Search 71 03 2009 Search SISTORE AX Search J Playback 44 foom Brightness If 2008 7 1 a ae Be pa ee 10 11 12 13 14 15 te taris Alka 22 24 25 26 27 28 29 al Fig 42 SISTORE AX Search More detailed information on the operation of SISTORE AX Search Watch and the SISTORE AX software can be found in t
80. olumn select Remove column To delete a row select Remove row gt A row or a column is now deleted 78 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Software monitors 13 Software monitors A software monitor is a component that is used to play digital live images on a VGA monitor Software monitors support the following digital video recorders and video servers e SISTORE SX CX e SISTORE AX e SISTORE MX e Telscan WEB Server il Max 21 live images can be displayed The IVM Client in Internet Explorer does not support SISTORE MX AX live images Output panel Favorites Fig 44 Software monitors Container The container with the software monitors visualizes the layout of the software monitors on the screen and the state of the software monitors The states of the software monitors are displayed in different colours Colour State Dark green Local activation visible only on the local client e g live image is displayed Light green Server controlled activation visible on all clients that are logged on e g a sequence group is activated red Alarm is active Pink Alarm is active live image has been closed manually Two types of software monitors are available in the IVM Client Software monitors to process alarms These software monitors are parameterized with IVM Config are known to the IVM Server and are used by this server to activate vide
81. ontext menu opens 2 Select Add to favorites gt The monitor is added to the favourites see Section 3 4 3 Favorites 77 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Monitors 12 7 Editing the favourites il The favourites are saved in the user profile see Section 17 User profiles Within the favourites monitors can be moved to free grid slots with drag amp drop and rows and columns can be added to or removed from the grid Add rows or columns to the grid 1 Right click on the grid in the Favorites tab gt The following context menu opens Add row Add column Remove row Remove column il Please note the following special features when adding grid rows or columns e A row or column is always added at the bottom or on the right The existing monitor layout is thus preserved 2 To add a column select Add column To add a row select Add row gt A row or a column is now added Remove rows or columns from the grid 1 Right click on the grid in the Favorites tab gt The following context menu opens Add row Add column Remove column Please note the following special features when removing grid rows or columns il e A deleted row or column is always removed from the bottom or the right e Monitors configured on the IVM Client are shifted to empty cells If there are no more empty cells the surplus monitors are deleted 2 To delete a c
82. op to add the required cameras to the corresponding table cells from the site plan or the device overview Enter the desired time interval in the Interval s column min 5 s Click on any blank cell of the table gt The value you have entered in the Interval s column will be applied Click OK gt A new sequence is now defined gt The sequence is added to the already defined sequences 03 2009 Configuration 5 4 3 Edit sequences Prerequisite The operator has the right Configure sequences More information can be found in the IVM Config Configuration Manual 1 Select the menu sequence Tools gt Sequences gt The Select sequence dialog opens see Fig 17 2 Select the sequence you would like to edit 3 Click Edit gt The following dialog box opens Name Output Device j MONITOR_ Camera Group Interval s carpark Fig 19 Configuring sequences Modify sequence 4 Make the desired changes see Section 5 4 2 Define a new sequence 5 Click OK gt Your settings are saved The sequence has been edited 37 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 5 4 4 Display sequences il 38 Siemens Building Technologies Fire Safety amp Security Products In a sequence the selected cameras are displayed on the screen one after another the display duration can be specified for each camera see Section 5 4 2 Define a new seque
83. ording has been started 1 Click on the desired camera icon in the device overview or on the site plan gt The following context menu opens Add to favorites Open archive ha Stop record Open camera Close all camera 2 Select Stop record from the context menu gt The red circle and the blue background are no longer visible gt Recording is stopped 74 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Monitors 12 Monitors 12 1 Monitor states and representation The shape and colour of the icons can be set up in the parameterization mode of the IVM Client The default symbols for the monitors are shown in the table below The output devices are represented according to their state Graphical representation Text below the icon State Name of the output device No display active on this output colour black device MOMTOR 2 Name of the active camera This camera is active on this output 4 colour green device For active sequences Seq suffix is added KAMERA 1 Name of the active camera This camera is active due to an colour red alarm activation Frame around the output The output device is active a device colour black camera can be switched to this device by quick selection double clicking on a camera 12 2 Show monitors There are two possible ways to display the monitors e Display monitors in the output panel e Display monitors as f
84. played 76 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Monitors 12 4 Activating cameras groups and sequences on monitors There are three possible ways to activate cameras groups and sequences on monitors e via the context menu e by drag amp drop e by quick selection See Section 8 2 Activating camera on output devices Section 5 3 4 Activate camera groups Section 5 4 4 Display sequences 12 5 Cancelling selections There are two possible ways to cancel a selection e By disconnecting By overwriting a selection Disconnect 1 Right click on the monitor for which you want to cancel the selection gt The following context menu opens Add to favorites Disconnect 2 Select Disconnect gt The name of the camera that was activated on the monitor is replaced by the monitor name gt The camera is disconnected from the monitor Overwrite 1 Select the monitor for which you want to change the current selection in the monitor bar gt The monitor is displayed in the monitor bar with a black frame around it 2 Double click on the desired camera icon in the device overview gt The new camera name is displayed in green below the monitor gt The camera that was originally activated on the selected monitor is overwritten by the new selection 12 6 Adding monitors to the favourites 1 Click on the monitor with the right mouse button gt The following c
85. quisite The operator has the right Configure groups More information can be found in the IVM Config Configuration Manual 1 Select the menu sequence Tools gt Groups gt The Select group dialog opens see Fig 14 2 Click New 30 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration gt The following dialog box opens W Group for switching Group for recherche Fig 15 Configuring camera groups New group 3 Enter the name of the camera group you wish to define 4 If desired enter a comment on the camera group in the Comment text field 5 Tick either of the two checkboxes to select the purpose of the camera group Group for switching By defining camera monitor pairs it is possible for the activation of the group to cause the activation of the corresponding camera on the monitor it is assigned to video management Group for recherche When searching for SISTORE SX CX recordings it is possible to search according to camera groups SISTORE SX CX camera groups e It is only possible to select cameras which are part of the site plan currently loaded Definition of il groups spanning multiple plans is not possible e f the camera group is only defined for SISTORE SX CX searching then it is not possible to select monitors since they are not required for this 6 Right click on the appropriate field of the table and select the desired cameras or monitors
86. r nuisance alarms and false alarms 1 Right click on an EDS or ODR alarm message in the alarm list EDS and ODR alarms can also be acknowledged and classified via the context menu of the alarm icon on the site plan See Section 6 2 Icons on the site plan gt The following context menu opens Acknowledge alarm real alarm Acknowledge selected alarms ice alarm Acknowledge all alarms O false alarm h Alarm pictures 2 Select Acknowledge alarm 96 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Alarm list message list and logbooks 3 Select the appropriate alarm type gt Real alarms are acknowledged immediately gt If the alarm is a nuisance alarm or a false alarm the following dialog box opens fea ton bird in front of lens insects in front of lens OK Cancel Fig 54 Classification of EDS and ODR alarms Reason comment 4 Select the category reason of the nuisance alarm or false alarm by activating the appropriate option il Comments can be up to 200 characters long 5 If desired enter a comment in the text field 6 Click OK gt The EDS or ODR alarm is acknowledged and classified 97 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Alarm list message list and logbooks 16 1 3 Starting search 1 Right click on the alarm list 2 Select Alarm pictures gt The following su
87. reen gt The live image of the camera is activated on the selected software monitor il You can use drag amp drop to drag the live image currently displayed to any other software monitor 13 4 Duplicate live image Prerequisite Alive image is being displayed 1 Press and hold lt Ctrl gt 2 Drag the live image you want to duplicate to the desired software monitor using drag amp drop gt The live image is duplicated 81 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Software monitors 13 5 Interchange live images on monitors You can interchange the software monitors of two live images on the screen Prerequisite 2 live images are being displayed 1 Press and hold lt Ctrl gt lt Shift gt 2 Use drag amp drop to drag one live image on top of the other gt The live images are interchanged 13 6 Select layout The default setting displays the software monitors used for alarm activation in the container in the form of a quad layout see Fig 44 1 Right click on a blank software monitor gt The following context menu opens t 1xCIF 12x0CIF Select software monitor 1xCIF 5xQCIF Live images position 1x4CIF 20x0CIF Show window 1xCIF BXOCIF O 2xCIF 8xQCIF 3x3 CIF Close lve images 2 Select Select layout 3 Click one of the following layouts Quad small Quad large Single frame 4CIF 1xCIF 12x
88. rm Status Status of the alarm active inactive or active acknowledged Priority Priority of the alarm 95 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Alarm list message list and logbooks e Device Device where the alarm occurred e Contact ID ofthe contact where the alarm occurred il More information can be found in the IVM Config Configuration Manual 16 1 1 Acknowledge alarms 1 Right click on the alarm list gt The following context menu opens Acknowledge Acknowledge selected alarms Acknowledge all alarms Alarm pictures 2 Select one of the following actions from the context menu Acknowledge alarm Acknowledge selected alarm Acknowledge selected alarms Acknowledge several selected alarms Acknowledge all alarms Acknowledge all alarms gt The alarms are acknowledged 16 1 2 Acknowledging and classifying EDS and ODR alarms You can classify EDS and ODR alarms when acknowledging them When the alarm messages have been classified it is possible to generate reports of nuisance alarms and false alarms see Section 16 3 5 Generate report of nuisance alarms or false alarms Prerequisites The option for the classification of EDS alarms is activated see Section 5 2 1 Activating deactivating classification of EDS and ODR alarms Categories for nuisance alarms and false alarm have been defined see Section 5 2 2 Defining a new category fo
89. rning Security The application s digital signature is invalid Do you want to run the application Name com siemens cctv ivmclient ui applets IYMLlient ppilet Publisher Siemens Building Technologies Fire amp Security Products GmbH amp Co oHG From hEkp 11192 168 0 50 Run Cancel The digital signature cannot be verified by a trusted source Only continue if you trust the origin of the application More Information Fig 9 IVM as an applet Security dialog We recommend to tick the checkbox Always trust content from this publisher If you do so you will not have to confirm this security dialog again 5 Click Run gt The login dialog opens see Section 4 2 3 Starting IVM Client as an application 6 Log in using the login dialog see Section 4 2 3 Starting IVM Client as an application gt IVM Client is now started as an applet 24 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Operational setup 4 2 3 Starting IVM Client as an application 1 Select the menu sequence Start gt Programs gt SIEMENS Video Software Suite gt IVM Client gt The following dialog box opens Clientversion 3 4 05 07 User Paseuorg Po Cx Connected to server 27 0 0 1 Fig 10 IVM as an application Login dialog 2 Select the desired language either German or English il The user name and password are predefined The entry is case se
90. s on a red background See Section 18 Trouble shooting A fault has occurred on a subordinate device component camera or monitor exclamation mark on a yellow background State of the device cannot be determined check configuration question mark on a blue background This state will only occur immediately after a server restart when some of the devices are not initialized yet The following devices are displayed in the device overview e Camera The cameras are sub nodes of the devices and displayed as such in the device overview You can use drag amp drop to load the cameras to the monitors of the monitor bar The various camera conditions are depicted by standard icons See Section 8 1 Camera states and representation e Monitor The monitors same as the cameras are sub nodes of the devices and depicted by standard icons as well 18 Siemens Building Technologies Fire Safety amp Security Products 03 2009 3 4 3 Favorites Software description il The Favorites tab is a component of the user profile see Section 17 User profiles and is saved on the server during logoff Devices Favorites amp O Favorites Lad Video Input 1 Cx 1 Showroom Lad Video Inputs Cx 1 Showroom EI video Output 1 EI video Output 2 Fig 6 Navigation zone Favorites tab The site plans cameras and monitors added to the favourites tree in the plan overview or device overview are added to the Favor
91. ser name and password once more The entry is case sensitive 2 Click OK See Section 4 2 3 Starting IVM Client as an application The device is not available The device is not connected to the network OR The connection has been lost OR The device is not switched on Connect the device to the network OR Contact your network administrator OR Switch the device on Display of live images from SISTORE SX CX is not possible The password of the SISTORE SX CX device is not identical with the password used in the IVM Client for logging into the SISTORE device Match the passwords The SISTORE SX CX search function is not working The password of the SISTORE device is not identical with the password used in the IVM Client for logging into the SISTORE device O The device name stored in IVM Config is not identical with that stored in SISTORE SX CX Config Match the passwords 0OR Match the device name Siemens Building Technologies Fire Safety amp Security Products If you have questions or suggestions regarding the product or this documentation please contact our Customer Support Center Intranet Customer Support Center Internet Worldwide contacts E Mail fs support sbt siemens com Tel 49 89 9221 8000 109 03 2009 Glossary 19 Glossary Double Common Intermediate Format Image format with a resolution of 704 horizontal pixels
92. sifying EDS and ODR alarms 96 Staring Sear Mesina a a a 98 MESSAgE IS anne ee E E 99 Acknowledge messages ssssececcceseececcceesecceceueeceeeseeaeeecesaaseeeeeeeas 100 Save MESSAGES isian a e a e 101 AlAT lOG iann a le a a N 102 Refresh alarm 1OQ cccccssscccssseecceeseeeceeseeeceeseeessaeeecsageeessegseesseeseeeses 102 DOM AIANINS 2er an N 103 Alarmi TOG SCANG I nee ner oe 103 Savealams sr ars Nein 104 Generate report of nuisance alarms or false alarms 104 EV SMOG ete alin Gicnrcicin tlcseietaeccadsauiaavadinataata N 105 DOM EVENTS ea a aa T 105 Event log seare He r E 106 SAVE CVENS aiga a e eek 106 USErprofle Sinni eelei 107 User relaled Drone scs stoke il 108 Workstation related profile cccccssssececeessecececeeeeeeeeecseeeeeeeseageeeeeseas 108 Trouble sho0ollng 2 2 a 109 Glos Saly aa a 110 MAEN anne a aa EEEa 111 7 03 2009 Description of functions 1 Description of functions 1 1 General functions Siemens Building Technologies Fire Safety amp Security Products With the IVM Client application software you can visualize and control a complete video system IVM Client offers the following functions Display of configured site plans with cameras Management of up to 256 cameras per plan Management of up to 20 plan referrals per plan Management of up to 120 multifunction icons or alarm icons per plan Display o
93. t Bottom left Bottom Bottom right Live player position F Manually Select layout Select software monitor Close players 3 Ifyou wish to define a specific live player position select Manually gt The following dialog box opens amp Set live player position L 1 OK Cancel Fig 46 Software monitors Manual entry of position 4 Specify the desired position of the live images e g 100 150 gt The first live image is opened on screen at position 100 150 13 10 Closing live images il Live images for the alarm processing will not be closed 1 Right click on the software monitor 2 Select Close live images from the context menu Select layout Select software monitor Live images position gt The live images are closed Siemens Building Technologies Fire Safety amp Security Products 85 03 2009 Software monitors 13 11 Manually closing live alarm images The live images for the alarm processing are displayed automatically if an alarm occurs for which alarm activation has been configured on the corresponding software monitor They are closed automatically if the triggering alarm is disabled Live images that were displayed as a result of an alarm can be closed manually 1 Right click on the appropriate live image 2 Select Acknowledge alarm from the context menu Select layout Live images position Close Ive images gt The
94. t alarms 103 Alarm logbook Applet Application C Camera groups Absolute activation Define Delete 34 33 Display Edit Relative activation Cameras Camera states Control Display Representation Change password 27 Classification 28 Activating 28 Configuring 28 Deactivating Define new categor Generate report Remove category 29 Closing the IVM Client E Event log 1105 Filter events Save events Sort events 105 Event logbook External programs Configuring 89 Running SISTORE SX CX Client 29 Siemens Building Technologies Fire Safety amp Security Products F Favorites 77 Add monitor Edit Fullscreen mode Functions H Hazard symbols Help Icons Alarm icon Camera icon Layer icons Multifunction icons Site plan Toolbar Internet Explorer J Java Runtime Environment JRE L Licence information Live images 65 Display Live image display eric Log off 26 Logbooks Login M Manual recording Starting Stopping 74 Message list 99 Acknowledge T es Save messages Monitors Hide Show 111 03 2009 Index N Navigation zone Device overview Favorites tree 19 Plan overview O Operating principle Output device Representation States P Performance 9 S Safety E SISTORE AX 70 SISTORE MX 68 SISTORE SX CX 66 Sections of the application window Selection of date Sequences
95. tion When a device error occurs After device error was corrected When an error occurs at the client or the server end When a warning message occurs at the client or the server end System messages occurring 16 2 1 Acknowledge messages 1 Select the message s you would like to acknowledge 2 Right click on a message that you have selected gt The following context menu opens Acknowledge selected messages Acknowledge all messages Save selected messages Save all messages 3 Select one of the following actions from the context menu Acknowledge message Acknowledge selected message Acknowledge selected Acknowledge several selected messages message Acknowledge all messages Acknowledge all messages gt The messages are acknowledged 100 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Alarm list message list and logbooks 16 2 2 Save messages 1 Select the message s you would like to save 2 Right click on a message that you have selected gt The following context menu opens Acknowledge message Acknowledge selected messages Acknowledge all messages EEE aber T Wier ee en eg eer eee coon eninetn bitrh n a ono Sat Li En Lr ed F I pe a Wes Save all messages 3 Select one of the following actions from the context menu Save selected messages The selected messages will be saved Save all messages All messages will be
96. ver the changed user profile settings are transferred to the server see Section 17 User profiles 1 Select the menu sequence File gt Exit gt The IVM Client is closed il Live images are not closed when the IVM Client started with Internet Explorer is closed 26 Siemens Building Technologies Fire Safety amp Security Products 03 2009 Configuration 5 Configuration 5 1 Change password il Siemens Building Technologies Fire Safety amp Security Products In a network of systems with SISTORE SX CX a user must be registered to the system with the same password for all devices 1 Select the menu sequence Tools gt Change password gt The following dialog box opens LIsername Old password Mew password Cancel Fig 11 Change password The entry is case sensitive The password must be at least 4 and not more than 16 characters in length Enter your current password in the Old password field Enter the new password in the New password field Enter the new password once more in the Password confirmation field Click OK gt Your password is now changed TP eS hb 27 03 2009 Configuration 5 2 Classifying EDS and ODR alarms With EDS and ODR detection nuisance alarms or false alarms caused by external factors cannot be excluded When acknowledging EDS and ODR alarm messages you can therefore specify the type of alarm Real alarm Nuisance alarm