Contents

1. Apply a continuous bead around coverslips 2 Wait 5 to 30 minutes 3 Denature incubate using your times temperatures 4 After incubation remove in one piece with forceps C Handling Slide Trays Ten slide trays are included with the CytoBrite Slide Oven Each removable tray holds 1 to 6 slides for assay setup and hybridization To load a slide tray on one of the heat blocks mounted on the sliding drawers hold the end tabs of the tray only avoiding direct contact with the slides and place the tray into the slots of the desired heat block such that the slides remain flat and The oven holds ten 6 slide trays level in full contact of the block Failure to properly insert the slide tray or slides may adversely affect performance D Using the Temperature Controller The CytoBrite Oven is equipped with a Watlow EZ Zone temperature controller shown at right It is calibrated at the factory to provide accurate chamber temperatures from ambient 5 to 90 C SciGene recommends checking calibration monthly The controller has two LED displays the upper display shows ACTUAL temperature inside the chamber and the lower display shows the SET or programmed temperature To program an oven temperature simply push the up or down arrows until the desired temperature is shown in the lower display The oven will adjust the heat of the chamber until the SET temperature is attained Two buttons are used during normal operation e The up arro
2. CytoBrite Slide Oven USER MANUAL Cat 2019 70 1 2 115 230V FOR RESEARCH USE ONLY 1287 Reamwood Avenue Sunnyvale CA 94089 USA e Tel 408 733 7337 Fax 408 733 7336 techserv scigene com Serial Number The following serial number identifies the specific oven you have purchased and must be referenced when requesting service A copy is affixed to the oven Technical Service 408 733 7337 techserv scigene com Warranty SciGene warrants that the heating unit described in this manual shall be free of defects in materials and workmanship for a period of 12 months from date of delivery This warranty does not cover removable slide trays or accessories In the event of a defect during the warranty period SciGene s limit of liability will be to provide replacement parts at no charge or at its sole discretion replace the product The foregoing warranty is void in the event the unit was abused or modified or used in a manner inconsistent with its intended purpose SciGene makes no other warranty expressed or implied including warranties of merchantability and fitness for a particular purpose In no event shall SciGene be liable for any direct indirect special incidental or consequential damages or for any damages resulting from loss arising out of or in connection with the sale use or performance of the product Copyright Copyright 2014 2015 SciGene Corporation All rights reserved SciGene CytoBrite and CytoBond are trad
3. Power Cord e User Manual Coverslip Sealant Requirements Ready to use CytoBond Removable Coverslip Sealant SciGene cat 2020 00 1 is required for use of the CytoBrite Slide Oven CytoBond Sealant is used to temporarily seal coverslips to slides providing an evaporative seal over prolonged incubations and high temperatures without humidification Environmental Requirements Ensure that the area where the CytoBrite Slide Oven is installed meets the following conditions for reasons of safety and performance 15 to 32 C 58 to 90 F Relative humidity 20 to 80 RH non condensing Air flow clearance 6 inches 15 cm minimum above unit Installation and Location Place the oven on a stable level surface within a few feet of the power source Allow 6 inches of clearance at top for adequate air flow DO NOT place under a shelf where solutions are stored Any liquid entering the electrical compartment through the vent holes on the top of the unit will cause damage Ensure there is adequate clearance on all sides of the oven which may be warm to the touch including enough space to open the door completely allowing for free movement of inner slide drawers Using only the power cord provided plug it into the back of the oven and then to a properly grounded outlet Turn on power using the ON OFF switch on the front control panel To avoid a safety hazard or damage to the instrument do not allow liquids to enter the vent holes on top
4. T certified digital thermometer SciGene cat 1051 52 0 is used to verify and set temperature calibration on the EZ Zone controller 408 733 7337 techserv scigene com IV MAINTAINING YOUR CYTOBRITE SLIDE OVEN A Powering Off Turn the power switch to the OFF position and unplug the power cord before performing any cleaning or service procedure B Cleaning the Oven Clean outer metal surfaces and drawers using a soft cloth and mild detergent based cleaner Avoid abrasive cleaners that can scratch surfaces Do NOT use caustic or strongly alkaline solutions e g strong soaps ammonia or bleach Under no circumstances should solutions be allowed to enter through the ventilation slots on the top of the oven If running radioactive or biohazardous reactions consult your institution s radiation safety officer or biosafety office for assistance Turn power switch to the OFF position and unplug the power cord before performing any cleaning procedure Tournez le commutateur d alimentation sur la position OFF et d branchez le cordon d alimentation avant d effectuer toute op ration de nettoyage Remove liquid or condensation wipe dry while oven is OFF and at room temperature Enlever le liquide ou la condensation essuyer tandis que l oven est teint et la temp rature ambiante C Checking and Replacing Fuses Two fuses are located in the removable block below the power cord receptacle on the top back of the o
5. Temp Variation Open Door Temperature Drop Digital Thermometer Output VI RELATED INSTRUMENTS REAGENTS AND ACCESSORIES 2019 00 1 CytoBrite Slide Incubation System 115V 230V Includes two 6 slide racks ER 2019 20 1 CytoBrite Duo Slide Incubation System 115 230V Includes two 6 slide racks ER 2010 00 2 FISH Wash Buffer 2 2xSSC 0 1 IGEPAL pH 7 EA EA EA EA A EA EA EA EA EA EA EA EA Version 1 0B April 2015 11 408 733 7337 techserv scigene com Vil DECLARATION OF CONFORMITY CytoBrite Slide Oven SciGene 4 1287 Reamwood Avenue Sunnyvale CA 94089 USA Declares that the above referenced product s meets the essential requirements of the following European Union Directives by using the relevant standards shown below to indicate compliance EMC Directive 2004 108 EC Standard IEC 61326 1 2005 Electrical equipment for measurement control and laboratory use LVD Directive 2006 95 EC Standards IEC 61010 1 2010 Electrical Equipment for Measurement Control and Laboratory use 3rd Edition Part 1 General requirements IEC 60204 1 2006 Electrical equipment of machines RoHS Directive 2011 65 EC Terry Gill Sunnyvale California USA Name of Authorized Place of Issue Representative Director of Product January 02 2015 Manufacturing Title of Authorized Date of Issue Representative TRE Signature of Authorized Representative Version 1 0B April 2015 12 408 733 7337 tech
6. ctromagnetic Compatibility EMC The CytoBrite Slide Oven is a Class A digital device under FCC Title 47 Part 15B and designated as Class A electrical equipment for measurement control and laboratory use EN61326 Note regarding Canadian EMC compliance Le present appareil numerique n emet pas de bruits radioelectrique depassant les limites applicables aux appareils numeriques de class A prescrites dans le reglement sur le brouillage radioelectrique edicte par le Ministere des Communications du Canada FCC Warnings and Notes This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC Rules The oven qualifies as an exempted device under 47 CFR 15 103 c in regard to the cited FCC regulations in effect at the time of manufacture Shielded cables must be used with this unit to ensure compliance with the Class A FCC limits H Compliance Electromagnetic Compatibility CE 1 All instruments shipped to the European Union EU formerly known as the European Community have the CE label on the back of the instrument signifying that these instruments comply with the Electromagnetic Compatibility and Low Voltage Directives 2 Restriction of Hazardous Substances RoHS The RoHS directive was adopted in February 2003 by the European Union It restricts with exceptions the use of six hazardous materials including lead RoHS and mercury in the manu
7. e OVE A catamovenien ede snicanaeaetcesianents 10 C Checking and Replacing GT 10 UC el Le a Oe KE 11 VI RELATED INSTRUMENTS REAGENTS AND ACCESSORIES ccecsccsccccsceccccececcsceceees 11 Vil DECLARATION OF CONFORMITY sassscscsicsiacaccsssnccncccasscntesansessecanesonedsincsneseniemessenebenesseteies 12 Version 1 0B April 2015 2 408 733 7337 techserv scigene com A SAFETY NOTICES Intended Use The CytoBrite Slide Oven incubates samples for FISH ISH applications using a radiant convection system within a stainless steel chamber to provide uniform heating The oven eliminates the need for humidification with the use of CytoBond Removable Coverslip Sealant The instrument should only be used according to the instructions provided in this manual If the equipment is used in a manner not specified by the manufacturer SciGene protection provided by the equipment may be impaired L incubateur CytoBrite est destin pour le chauffage d chantillons biologiques L oven ne devrait servir que selon les instructions fournies dans ce manuel de l utilisateur et d autres documents techniques de SciGene Si l quipement est utilis de mani re non sp cifi e par le fabricant la protection assur e par l quipement peut tre compromise Oven Safety Before operating the oven read the information in this section concerning hazards and potential hazards Ensure that anyone involved with the oven s operation is instruct
8. ed in both general safety practices for laboratories and specific safety practices for the oven Avant le fonctionnement de l oven lisez les renseignements dans cette section concernant les risques et les dangers potentiels S assurer que toute personne impliqu e avec le fonctionnement de l oven est instruit dans les pratiques g n rales de s curit pour les laboratoires et les pratiques de s curit sp cifiques pour l oven Avant le fonctionnement de l oven lisez les renseignements dans cette section concernant les risques et les dangers potentiels S assurer que toute personne impliqu e avec le fonctionnement de l oven est instruit dans les pratiques g n rales de s curit pour les laboratoires et les pratiques de s curit sp cifiques pour l oven Symbols and Conventions The following chart is an illustrated glossary of the electrical symbols that are used on the CytoBrite Slide Oven Whenever such symbols appear on ovens please observe appropriate safety measures Le tableau suivant est un glossaire illustr des symboles lectriques qui sont utilis es sur le systeme Chaque fois que ces symboles apparaissent sur les ovens veuillez observer les mesures de s curit appropri es 1 Electrical Symbols This symbol indicates that this is a protected ground terminal that must be connected to earth ground before any other electrical connections are made to the oven Ce symbole indique qu il s agit d un terminal de terrain p
9. emarks of SciGene Corporation Sunnyvale CA All other trademarks used in this manual are the property of their respective owners Version 1 0B April 2015 1 408 733 7337 techserv scigene com Table of Contents l SAFETY NOTICES si ccsessesstcccssccencsseasincscveswsacananaasacnssiaesssedsesesssesssacnssecsssesiansassacesisaessaesaansosns 3 A NSTC U E 3 E e e E EE 3 SIMO IS Une KR e CIELO E 3 WN TE 4 Be e Le EEE 4 F Electromagnetic Compatibility EMC EE 5 G ee le Met 5 e OIA Ee 5 He UNPACKING AND SET UP ege eege eu gef eEee 6 A Unpacking Lifting and Moving the Oven siennes 6 SSP OI eceeceree scence casein ancissu os Saainetencseecgeesantsnnsceeeseescaneuscacoe seueneaienancoeysasereunnsdeeetteasaeanscessiene 6 Cs COVEPSIID Sealant Requirements E 6 D Environmental ReQUIT AENRSS aan caen ae tenants stat one elements lee le ee 6 eS AO A OG ALO BE 6 il USING YOUR CYTOBRITE SLIDE OVEN ss see sense ones cena sos specmeensscossecreseosee 7 A Components Controls and Accessories siennes 7 B Using CytoBond Removable Coverslip Sealant ss 8 Ge A Naun SHOP FANS A ete eue a ai dd aa nt ce dia tee 8 D Using the Temperature COMO CF sieeve csecissszccssenscoasentwantinabackcerassesageeceneneebiwetayeanneneaiacebinaneeauenseanees 8 E Calibrating the Temperature Controller ss 9 IV MAINTAINING YOUR CYTOBRITE SLIDE OVEN cecsscsccccscsccscecsccscecsscsceecsceeseees 10 E PONEN O a en 10 D Cleaning M
10. facture of various types of electronic equipment All SciGene instruments carrying the CE mark are also ROHS compliant 3 Electrical and Electronic Equipment Waste WEEE WEEE is a European Community directive that became European Law in February 2003 The crossed out wheelie bin symbol on a product or its packaging indicates that it must NOT be disposed of with standard waste at the end of its lifetime Instead it is your responsibility to return it to a designated collection point for electronic equipment recycling Contact your local SciGene distributor for information on drop off locations Version 1 0B April 2015 5 408 733 7337 techserv scigene com UNPACKING AND SET UP Unpacking Lifting and Moving the Oven The CytoBrite Slide Oven is shipped with ten empty slide trays in a single carton The oven weighs approximately 100 lbs 45 kg so extreme caution is needed when lifting the unit to protect yourself and others from personal injury Two people are required to lift the unit one on each side keeping it balanced and sharing the load Remove any packing material from around the top and sides of the oven then carefully lift out place on the bench and inspect for damage If the oven is damaged upon arrival please retain all shipping materials and contact SciGene or your local distributor for assistance Items Provided The following items are included in the shipping carton with the CytoBrite Slide Oven e 10x Slide Trays e
11. lowing warnings that are affixed to the product can lead to possible personal injury or death D faut de respecter les avertissements suivants qui sont appos es sur le produit peut conduire possibles l sions corporelles ou la mort This symbol on the rear of the oven indicates the presence of the fuse box AN Warning For Continued Protection Against Fire Replace Only with Same Type Rating of Fuse Always disconnect the power cord before attempting to replace the fuse Ce symbole sur l arri re de l oven indique la pr sence de la bo te de fusibles Avertissement Pour le maintien de la Protection contre l incendie remplacer uniquement avec la m me cote de Type de fusible Toujours d brancher le cordon d alimentation avant d essayer de remplacer le fusible E Cautions Failure to comply with the following cautionary statement affixed to the product may lead to possible personal injury Omission de se conformer la mise en garde suivante appos e sur le produit peut entra ner des blessures possibles Version 1 0B April 2015 4 408 733 7337 techserv scigene com F This symbol located on the oven drawers indicates the potential presence of a Hot Surface Use care when working in this area to avoid being burned Ce symbole situ en face des blocs de chaleur indique la pr sence ventuelle d une surface chaude Faire preuve de diligence lorsqu il travaille dans ce domaine pour viter d tre br l Ele
12. ne controller 1 2 d b No Continue with the steps below Yes STOP the oven is correctly calibrated Turn on the oven set to 37 C and allow temperature to stabilize 6 hours Connect a NIST certified T type digital thermometer SciGene Cat 1051 52 0 to the blue jack secondary RTD at the top back of the oven Does the digital thermometer reading match the controller to 0 5 C 4 Calculate the temperature difference from the controller to the thermometer For example if the controller displays 37 0 C and the thermometer displays 38 5 C the difference offset is 1 5 C On the controller press the up and down arrows simultaneously for 3 seconds The upper display shows A1 and the lower display reads open Press the advance button circle icon 3 times until the lower display shows i CA The upper display shows the offset value when the unit was last calibrated Use the up down arrows to adjust this value to the new offset calculated in Step 4 For example if the controller reads 1 5 C lower than the thermometer adjust the offset by adding 1 5 to the value shown 8 Version 1 0B April 2015 D LES y d A NIS j i Il Il il Ri Vi lal d H Press the infinity key twice to return to the operation display The oven is now calibrated to provide accurate temperatures from ambient 5 to 90 C
13. of the oven ee SciGene CytoBrite Slide Oven Version 1 0B April 2015 6 408 733 7337 techserv scigene com lil USING YOUR CYTOBRITE SLIDE OVEN A Components Controls and Accessories Po Name Function Power Suitch Tums ON OFF powertotheoven Heat Blocks 5 Mounted on drawers heats slides held in trays Slide Trays 10 Holds slides for transfer and incubation CytoBond Removable Coverslip Seals coverslips to slides without humidification Sealant Digital Thermometer optional Used to verify and calibrate block temperatures Temperature Calibration Jack Connection for optional digital thermometer SlideSense Temperature Sensor Temperature Calibration Jack Power Switch in back Temperature Controller LG CytoBond Removable Coverslip Sealant cat 2020 00 1 Required Digital Thermometer cat 1051 52 0 Optional Power Switch A geen CLII 7 Adaptor Input Sliding Drawer Door Latch Slide Tray Heat Block Version 1 0B April 2015 7 408 733 7337 techserv scigene com B Using CytoBond Removable Coverslip Sealant The CytoBrite Slide Oven eliminates the need for humidification with the use of CytoBond Removable Coverslip Sealant SciGene cat 2020 00 1 CytoBond is a gel like adhesive applied to coverslips that temporarily seals them to slides Follow the steps below to prepare slides with CytoBond Sealant 1
14. rot g qui doit tre connect la terre avant que toutes les autres connexions lectriques sont apport es l oven Version 1 0B April 2015 3 408 733 7337 techserv scigene com SciGene A CytoBrite Slide Oven USER MANUAL CAUTION This symbol warns of an electrical hazard and alerts you to consult this Operator s Manual for further information and to proceed with caution ATTENTION Ce symbole vous avertit consulter ce guide de l utilisateur pour plus d informations et de proc der avec prudence This symbol indicates the OFF position of the main POWER switch Ce symbole indique la position OFF de l interrupteur principal This symbol indicates the ON position of the main POWER switch Ce symbole indique la position ON de l interrupteur principal 2 Non Electrical Symbols A A D Warnings CAUTION This symbol illustrates a heat hazard Proceed with caution when working around these areas to avoid being burned by hot components ATTENTION Ce symbole illustre un danger pour la chaleur Faire preuve de prudence lorsque vous travaillez autour de ces zones pour viter d tre br l par les composants du chauds CAUTION This symbol alerts you to consult this Operator s Manual for further information and to proceed with caution ATTENTION Ce symbole vous avertit consulter ce guide de l utilisateur pour plus d informations et de proc der avec prudence Failure to comply with the fol
15. serv scigene com
16. ven Blown fuses will have a broken filament or appear dark Always replace fuses with the same amperage and voltage as shown on the label below the fuse block A Turn power switch to the OFF position and unplug the power cord before performing any service procedure Tournez le commutateur d alimentation sur la position OFF et d branchez le cordon d alimentation avant d effectuer toute op ration de service Wh Pry open tab To remove fuses with screwdriver 1 Insert a small flat blade screwdriver into the tab recess just below the plug receptacle d Fuse hold 2 Push down to release the fuse block n Th SCH 3 Slide fuse holder out from the fuse block while Push clip up holding the retaining tab out of the way LE to release 4 Gently pry out the fuses Fuse block Version 1 0B April 2015 10 408 733 7337 techserv scigene com TROUBLESHOOTING Oven does not turn on Blown fuse s Replace fuse s on back of unit beneath power cord receptacle Controller is not responding Controller is faulty or is Cycle oven on and off Contact when buttons are pressed not properly programmed SciGene or your local distributor to replace the controller if necessary V SPECIFICATIONS Cat 2019 70 1 115V AC 50 60 Hz 6A Cat 2019 70 2 230V AC 50 60 Hz 3A Dimensions and Weight Outside H x W xD 22 x 18 x 17 inches 55 x 45 x 42 cm Weight 100 Ibs 45 kg Performance and Controls iide to slide
17. w A is used to program a higher temperature and for calibration e The down arrow 7 is used to program a lower temperature and for calibration Three buttons are used for calibration or factory settings only e The infinity button ce is used to adjust power settings for the chamber heaters or for exiting calibration mode It is programmed at the factory to provide 100 power and should NOT be used during normal operation e The advance button circle icon at lower left is used to scroll through parameters during calibration It is NOT used during normal operation e The EZ button is used for advanced functions NOT applicable to this oven model It should NOT be used during normal operation Version 1 0B April 2015 8 408 733 7337 techserv scigene com SciGene E Calibrating the Temperature Controller CytoBrite Slide Oven USER MANUAL To ensure accurate 0 5 C oven temperatures the performance of the EZ Zone controller should be periodically checked by comparing the temperature displayed on the controller to an accurate NIST certified National Institute of Standards and Technology thermal measurement device Calibration need only be performed at a single temperature e g 37 C to achieve accurate oven operating temperatures from ambient 5 to 90 C SciGene recommends the calibration method below to achieve accurate oven temperatures No other methods are recommended Follow the steps below to calibrate the EZ Zo