1. red light does not Problem Solution When power e Ensure mains power is connected and switched on at supply is the wall socket Ensure the polarity of plug pack is correct If VMD 19M is connected to a security system ensure turn on that VMD 19M is armed by the security system Motion is not e Ensure that the camera is on detected e Check that the camera video lead is connected to the Video In Change to a higher sensitivity False motion is detected Change to a lower sensitivity Scene contains a window to outside or moving background objects such as trees or cars Camera might be generating large video noise Change to a better quality camera VMD 19M does not operate the VCR Ensure that the IR Transmitter is placed in front of the remote control sensor of the VCR Ensure that the VCR is turned on and has a tape inside it and test its operation with its own remote controller Repeat the IR code learning procedure Image from the camera is not recorded Ensure that the Video Out from the VMD 19M is connected to the AV Video input of the VCR Ensure that the VCR is set to the AV channel Technical Specification Video Format NTSC PAL EIA CCIR and SECAM video standards Video Input 75Q 1Vpp composite video via RCA connector Video Output Passive loop through from Video Input IR Input 950nm Infra red signal from a standard appliance remot
2. R when triggered by an external device such as a door window sensor or a PIR motion sensor or an electronic security system ial Aena IR Transmitter TV IN VMD19 M Audio Video 7 5 24 Video Remote 4 3 2 1 VDC fOut In Out In O O gt Q o RCA Lead Installation l Connection to a Security System This installation procedure assumes that you have already installed a security camera at a suitable indoor location and have a VCR with a remote controller unit for recording video events The installation procedure is divided into two sections The Advanced Installation section is for users who are technically minded and want to explore all the advanced options or want to connect the VMD 19M to an existing electronic alarm system All other users can skip this section and go straight to the Basic Installation section Advanced Installation Sensitivity Setting VMD 19M can be set to 4 different sensitivities for motion detection When set at highest sensitivity 4 small changes in the scene will be detected Lower sensitivity is suitable where the camera is not of a very high quality and has some image noise If you do not want to detect small object movements such as pets a lower sensitivity might be suitable VMD 19M is set to sensitivity level 3 at factory and is suitable for most applications You can change the sensitivity using the DIP switch provided on the circuit board of the VMD 19M as follo
3. VMD 19M Video Motion Detector with Automatic Video Recording M M Remotejj Remote Video Arm 7 5 248 1 2 3 4 In Out Out VDC 09 0 Out In VMD 19M ee ee Video Motion Detector VCR Commander USER MANUAL Version 1 3 VMD 19M works with a video camera a VCR and optionally an electronic security system VMD 19M detects a moving object in the video signal received from the video camera VMD 19M is designed specifically to detect walking of people and movement of larger objects under controlled lighting conditions and for indoor use However the sensitivity of VMD 19M to detect motion is adjustable Therefore it can be made insensitive to the motion of small pets The VMD 19M can learn the remote control codes from the remote controller unit of most VCRs When the VMD 19M detects a motion the red light will flash momentarily and the VMD 19M will put the VCR into RECORD mode At the same time alarm output relay contacts will close momentarily After 30 seconds of non motion the VMD 19M will PAUSE the VCR If there is no motion for a further 2 5 minutes then the VMD 19 will STOP the VCR If motion is detected while the VCR is paused the VMD 19M will put the VCR back into RECORD mode and close the alarm output relay contacts momentarily If the video signal from the camera is lost the alarm output relay contacts will close When the video signal is restored the relay contacts will open The VMD 19M also controls the VC
4. e controller IR output same as IR Input Power Supply 7 5VDC to 24VDC at 100mA minimum Indicator Red LED Sensitivity Via 2 way dip switch for size and contrast Adjustment Controls Available on screw terminals External Trigger input to activate recording Motion output or video signal loss via relay contact closure Enclosure case Metal powder coated in silver Dimensions 104mm x 52mm x 25mm Weight Approx 200gr VMD 19M has a warranty of 12 months against defects in workmanship and materials after the original date of purchase In the event of failure the supplier will replace or repair it at its option providing there is no evidence of customer misuse or alteration Customer is responsible for shipping costs to and from the supplier MANUFACTURER DISTRIBUTORS AND DEALERS OF THE VMD 19M MAY NOT BE HELD LIABLE FOR INJURY LOSS OR DAMAGE DIRECT INDIRECT OR CONSEQUENTIAL ARISING OUT OF THE USE OR INABILITY TO USE THE VMD 19M THIS INCLUDES BUT IS NOT LIMITED TO THE FAILURE OF VMD 19M TO PERFORM AS ADVERTISED
5. e and remain closed until the video signal is restored When a motion is detected relay contacts will close momentarily Security System Panel VMD 19M Relay Output 75 24 video Remote 4 3 2 4 VDC Out In Out In Fag Pipl g eo o gt Gens a a do ee Close Motion Motion Output Signal Basic Installation Please read all the following steps before starting the installation process 1 2 10 11 12 13 14 15 Connect the video cable from the video camera to the Video In at the back of the VMD 19M Connect one end of the RCA video cable supplied in the packaging to the Video Out at the back of the VMD 19M and the other end to the AV video input of the VCR Connect the IR transmitter cable to the Remote Out of the VMD 19M and place the transmitter in front the remote control sensor of the VCR It is important that the signals from the transmitter can reach the sensor of the VCR otherwise the VMD 19 can not control the VCR Test the suitability of the location by trying to control the VCR with its own remote controller unit at the same location that you have placed the IR transmitter Have the remote controller of the VCR ready Put a blank video tape in the VCR turn the VCR on and set its input channel to AV channel or Line In if unsure refer to your VCR user guide Ensuring the correct polarity and connection on the power supply connect a plug pack power su
6. pply delivering a voltage between 7 5VDC and 24VDC to the 7 5 24VDC connector on the back of the VDM19 M Minimum current of 100mA is required The red light on the VMD 19M should now be on Wait for a few seconds until the red light starts flashing Hold the VCR remote controller unit about 30cm away from the back of the VMD 19M and point towards the Remote In of the VMD 19M Press and hold the RECORD button on the VCR remote controller until the red light stops flashing for a couple of seconds Wait until the red light starts flashing again Press and hold the PAUSE button on the VCR remote controller until the red light stops flashing for a couple of seconds Wait until the red light starts flashing again Press and hold the STOP button on the VCR remote controller until the red light stops flashing for a couple of seconds Wait until the red light starts flashing again Press and hold the ON OFF or POWER button on the VCR remote controller until the red light stops flashing VMD 19M will now transmit the RECORD signal Check to ensure that the VCR is now recording If the VCR is recording stop it In this case the VMD 19M has learnt the codes and can control your VCR If the VCR is not recording you have to repeat steps 5 to 15 again If you have done all the installation steps the VMD 19M should now be ready to detect motions in video signals from the camera and activate the VCR recording Troubleshooting connected
7. wing 1 Undo the screws on the sides of the VMD 19M 2 Remove the cover 3 Set the DIP Switch based on this table Sensitivity Tab Switch1 Tab Switch 2 1 lowest ON ON 2 ON OFF 3 factory setting OFF ON 4 highest OFF OFF Example To set the sensitivity to 2 set the Tab Switch 1 to the ON position and the Tab Switch 2 to the OFF position VMD 19M has a 4 pin screw terminal block for interfacing to control systems such as an electronic security system Arm and Disarm A security system can arm and disarm the VMD 19M by controlling the power supplied to the VMD 19M When the power is supplied to the VMD 19 it is automatically armed otherwise it is disarmed Trigger Recording Most VCRs take around 4 seconds to start recording after an alarm trigger For faster response VMD 19M provides a Normally Open NO input for pre alarm external trigger recording Connect the terminals marked 3 and 4 to relay contacts of the security system A security system can trigger the VCR recording by closing the relay contacts thus shortening the terminal number 3 and 4 together After 30 seconds that the contacts remain open the VMD 19 will pause and after a further 2 5 minutes will stop the VCR Motion or Video Loss Output VMD 19M provides a Normally Open NO relay contact output at terminals 1 and 2 for motion detection and video loss signalling When video signal is lost the relay contacts will clos

Download Pdf Manuals

image

Related Search

Related Contents

Jabra PRO™ 930 - WordPress.com  Bienvenue au Wolu Plongée Club    Milwaukee B51A User's Manual  Owner`s Manual  Massive Suspension light 41648/53/10  EOS 70D (W) EOS 70D (N)  Réussir les luttes naturelles de contre saison avec des races  Betriebsanleitung CHIEMSEE - Spechtenhauser  Marin FRS Quad-Link Service Manual  